STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 1,001–1,100 of 47,868
Reed, E. F., Rao, P., Zhang, Z., Gebel, H., Bray, R. A., Guleria, I., Lunz, J., Mohanakumar, T., Nickerson, P., Tambur, A. R., et al. (2013) · American Journal of Transplantation · doi:10.1111/ajt.12287 · Cited by 245
Ghoussayni, S., Stevens, C., Durham, S., & Ewins, D. (2004) · Gait & Posture · doi:10.1016/j.gaitpost.2003.10.001 · Cited by 244
Xia, J. J., Gateno, J., Teichgraeber, J. F., Christensen, A. M., Lasky, R. E., Lemoine, J. J., & Liebschner, M. A. K. (2007) · Journal of Oral and Maxillofacial Surgery · doi:10.1016/j.joms.2006.10.005 · Cited by 249
Hamilton, J. I., Jiang, Y., Chen, Y., Ma, D., Lo, W.-C., Griswold, M., & Seiberlich, N. (2017) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26216 · Cited by 246
Assessing the reliability, discriminative ability, and validity of disability glare tests.
Elliott, D. B., & Bullimore, M. A. (1993) · PubMed · Cited by 246
Agarwal, R., Peixoto, A. J., Santos, S. F. F., & Zoccali, C. (2006) · Clinical Journal of the American Society of Nephrology · doi:10.2215/cjn.01891105 · Cited by 245
SpiroSmart: using a microphone to measure lung function on a mobile phone
Larson, E. C., Goel, M., Boriello, G., Heltshe, S., Rosenfeld, M., & Patel, S. N. (2012) · Proceedings of the 2012 ACM Conference on Ubiquitous Computing · doi:10.1145/2370216.2370261 · Cited by 245
Schwartz, G. J., Furth, S., Cole, S. R., Warady, B., & Muñoz, A. (2006) · Kidney International · doi:10.1038/sj.ki.5000385 · Cited by 242
Kurtze, N., Rangul, V., & Hustvedt, B.-E. (2008) · BMC Medical Research Methodology · doi:10.1186/1471-2288-8-63 · Cited by 247
Forecasting Emergency Department Crowding: A Discrete Event Simulation
Hoot, N. R., LeBlanc, L. J., Jones, I., Levin, S. R., Zhou, C., Gadd, C. S., & Aronsky, D. (2008) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2007.12.011 · Cited by 244
Blood lactate monitoring in critically ill patients: A systematic health technology assessment *
Jansen, T. C., van Bommel, J., & Bakker, J. (2009) · Critical Care Medicine · doi:10.1097/00003246-200910000-00022 · Cited by 247
Thickness of Acquired Salivary Pellicle as a Determinant of the Sites of Dental Erosion
Amaechi, B. T., Higham, S. M., Edgar, W. M., & Milosevic, A. (1999) · Journal of Dental Research · doi:10.1177/00220345990780120901 · Cited by 248
Dark, P. M., & Singer, M. (2004) · Intensive Care Medicine · doi:10.1007/s00134-004-2430-2 · Cited by 245
Neame, R. L., Carr, A. J., Muir, K., & Doherty, M. (2003) · Annals of the Rheumatic Diseases · doi:10.1136/ard.62.6.513 · Cited by 250
Lemmers, P. M. A., Toet, M. C., & van Bel, F. (2008) · Pediatrics · doi:10.1542/peds.2007-0925 · Cited by 244
Postsystolic Shortening in Ischemic Myocardium: Active Contraction or Passive Recoil?
Skulstad, H., Edvardsen, T., Urheim, S., Rabben, S. I., Stugaard, M., Lyseggen, E., Ihlen, H., & Smiseth, O. A. (2002) · Circulation · doi:10.1161/01.cir.0000024102.55150.b6 · Cited by 247
Can Wearable Devices Accurately Measure Heart Rate Variability? A Systematic Review
Georgiou, K., Larentzakis, A. V., Khamis, N. N., Alsuhaibani, G. I., Alaska, Y. A., & Giallafos, E. J. (2018) · Folia Medica · doi:10.2478/folmed-2018-0012 · Cited by 244
Fountoulakis, K. N., Papadopoulou, M., Kleanthous, S., Papadopoulou, A., Bizeli, V., Nimatoudis, I., Iacovides, A., & Kaprinis, G. S. (2006) · Annals of General Psychiatry · doi:10.1186/1744-859x-5-2 · Cited by 238
Quantitative Measurements of Autofluorescence with the Scanning Laser Ophthalmoscope
Delori, F., Greenberg, J. P., Woods, R. L., Fischer, J., Duncker, T., Sparrow, J., & Smith, R. T. (2011) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.11-8319 · Cited by 243
Alfakih, K., Plein, S., Bloomer, T., Jones, T., Ridgway, J., & Sivananthan, M. (2003) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10329 · Cited by 246
Boardman, J. P., Counsell, S. J., Rueckert, D., Kapellou, O., Bhatia, K. K., Aljabar, P., Hajnal, J., Allsop, J. M., Rutherford, M. A., & Edwards, A. D. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.03.029 · Cited by 247
Renal Volume Measurements: Accuracy and Repeatability of US Compared with That of MR Imaging
Bakker, J., Olree, M., Kaatee, R., de Lange, E. E., Moons, K. G. M., Beutler, J. J., & Beek, F. J. A. (1999) · Radiology · doi:10.1148/radiology.211.3.r99jn19623 · Cited by 248
Validity and Reliability Issues in Educational Research
Oluwatayo, J. A. (2012) · Journal of Educational and Social Research · Cited by 469
Monitoring blood glucose control in diabetes mellitus: a systematic review.
Coster, Gulliford, Seed, Powrie, & Swaminathan (2000) · Health Technology Assessment · doi:10.3310/hta4120 · Cited by 245
Meta-analysis of arterial oxygen saturation monitoring by pulse oximetry in adults
Jensen, L. A., Onyskiw, J. E., & Prasad, N. G. N. (1998) · Heart & Lung · doi:10.1016/s0147-9563(98)90086-3 · Cited by 243
Radiomorphometric indices of the mandible in a British female population
Ledgerton, D., Horner, K., Devlin, H., & Worthington, H. V. (1999) · Dentomaxillofacial Radiology · doi:10.1038/sj.dmfr.4600435 · Cited by 243
Moore, T., Johnson, S., Haider, S., Hennessy, E., & Marlow, N. (2012) · The Journal of Pediatrics · doi:10.1016/j.jpeds.2011.09.047 · Cited by 246
Lovett, P. B., Buchwald, J. M., Stürmann, K., & Bijur, P. (2005) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2004.06.016 · Cited by 244
Story, D. A., Morimatsu, H., & Bellomo, R. (2004) · British Journal of Anaesthesia · doi:10.1093/bja/aeh018 · Cited by 249
Comparative accuracy of Doppler echocardiographic methods for clinical stroke volume determination
Dubin, J., Wallerson, D. C., Cody, R. J., & Devereux, R. B. (1990) · American Heart Journal · doi:10.1016/0002-8703(90)90168-w · Cited by 244
The patient-centredness of consultations and outcome in primary care.
Kinnersley, P., Stott, N. C. H., Peters, T. J., & Harvey, I. M. (1999) · Europe PMC (PubMed Central) · Cited by 242
Balsalobre-Fernández, C., Tejero-González, C. M., del Campo-Vecino, J., & Bavaresco, N. (2014) · Journal of Strength and Conditioning Research · doi:10.1519/jsc.0b013e318299a52e · Cited by 240
Field Validation of the MTI Actigraph and BodyMedia Armband Monitor Using the IDEEA Monitor
Welk, G. J., McClain, J. J., Eisenmann, J. C., & Wickel, E. E. (2007) · Obesity · doi:10.1038/oby.2007.624 · Cited by 244
Schellingerhout, J. M., Verhagen, A. P., Heymans, M. W., Koes, B. W., de Vet, H. C., & Terwee, C. B. (2012) · Quality of Life Research · doi:10.1007/s11136-011-9965-9 · Cited by 241
Schelbert, E. B., Testa, S. M., Meier, C. G., Ceyrolles, W. J., Levenson, J. E., Blair, A. J., Kellman, P., Jones, B. L., Ludwig, D. R., Schwartzman, D., et al. (2011) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-13-16 · Cited by 242
Tae, W. S., Kim, S. S., Lee, K. U., Nam, E.-C., & Kim, K. W. (2008) · Neuroradiology · doi:10.1007/s00234-008-0383-9 · Cited by 244
Wolever, T. M. S. (2004) · British Journal of Nutrition · doi:10.1079/bjn20031054 · Cited by 242
The measurement of reticular basement membrane and submucosal collagen in the asthmatic airway
WILSON, J. W., & LI, X. (1997) · Clinical <html_ent glyph="@amp;" ascii="&"/> Experimental Allergy · doi:10.1046/j.1365-2222.1997.600864.x · Cited by 243
Geva, T., Greil, G. F., Marshall, A. C., Landzberg, M., & Powell, A. J. (2002) · Circulation · doi:10.1161/01.cir.0000023624.33478.18 · Cited by 245
Sanada, K., Kearns, C. F., Midorikawa, T., & Abe, T. (2006) · European Journal of Applied Physiology · doi:10.1007/s00421-005-0061-0 · Cited by 241
‘Structure–function relationship’ in glaucoma: past thinking and current concepts
Malik, R., Swanson, W. H., & Garway‐Heath, D. F. (2012) · Clinical & Experimental Ophthalmology · doi:10.1111/j.1442-9071.2012.02770.x · Cited by 235
Metabolomics Applied to Exhaled Breath Condensate in Childhood Asthma
Carraro, S., Rezzi, S., Reniero, F., Héberger, K., Giordano, G., Zanconato, S., Guillou, C., & Baraldi, E. (2007) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200606-769oc · Cited by 242
Halpern, S. D., & Taichman, D. B. (2009) · Chest · doi:10.1378/chest.08-2784 · Cited by 245
Galvão, K. N., Flaminio, M. J. B. F., Brittin, S. B., Sper, R., Fraga, M., Caixeta, L., Ricci, A., Guard, C. L., Butler, W. R., & Gilbert, R. O. (2010) · Journal of Dairy Science · doi:10.3168/jds.2009-2551 · Cited by 241
Grau, M., Elosua, R., Cabrera de León, A., Guembe, M. J., Baena-Díez, J. M., Vega Alonso, T., Javier Félix, F., Zorrilla, B., Rigo, F., Lapetra, J., et al. (2011) · Revista Española de Cardiología (English Edition) · doi:10.1016/j.rec.2010.11.005 · Cited by 240
Analytical and clinical validation of the 25 OH vitamin D assay for the LIAISON® automated analyzer
Ersfeld, D. L., Rao, D. S., Body, J.-J., Sackrison, J. L., Miller, A. B., Parikh, N., Eskridge, T. L., Polinske, A., Olson, G. T., & MacFarlane, G. D. (2004) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2004.06.006 · Cited by 243
Accuracy and reliability of the ParvoMedics TrueOne 2400 and MedGraphics VO2000 metabolic systems
Crouter, S. E., Antczak, A., Hudak, J. R., DellaValle, D. M., & Haas, J. D. (2006) · European Journal of Applied Physiology · doi:10.1007/s00421-006-0255-0 · Cited by 240
Walch, O., Huang, Y., Forger, D., & Goldstein, C. (2019) · Sleep · doi:10.1093/sleep/zsz180 · Cited by 240
Niven, D. J., Gaudet, J. E., Laupland, K. B., Mrklas, K. J., Roberts, D. J., & Stelfox, H. T. (2015) · Annals of Internal Medicine · doi:10.7326/m15-1150 · Cited by 240
Recall of severe hypoglycaemia and self‐estimated state of awareness in type 1 diabetes
Pedersen‐Bjergaard, U., Pramming, S., & Thorsteinsson, B. (2003) · Diabetes/Metabolism Research and Reviews · doi:10.1002/dmrr.377 · Cited by 240
A Hattori chart analysis of body mass index in infants and children
Wells, J. (2000) · International Journal of Obesity · doi:10.1038/sj.ijo.0801132 · Cited by 240
McCamley, J., Donati, M., Grimpampi, E., & Mazzà, C. (2012) · Gait & Posture · doi:10.1016/j.gaitpost.2012.02.019 · Cited by 241
D'Alto, M., Romeo, E., Argiento, P., D'Andrea, A., Vanderpool, R., Correra, A., Bossone, E., Sarubbi, B., Calabrò, R., Russo, M. G., et al. (2013) · International Journal of Cardiology · doi:10.1016/j.ijcard.2013.07.005 · Cited by 237
Shepherd, H. L., Barratt, A., Trevena, L. J., McGeechan, K., Carey, K., Epstein, R. M., Butow, P. N., Del Mar, C. B., Entwistle, V., & Tattersall, M. H. N. (2011) · Patient Education and Counseling · doi:10.1016/j.pec.2011.07.022 · Cited by 230
Quantitative monitoring of multispecies fish environmental DNA using high-throughput sequencing
Ushio, M., Murakami, H., Masuda, R., Sado, T., Miya, M., Sakurai, S., Yamanaka, H., Minamoto, T., & Kondoh, M. (2018) · Metabarcoding and Metagenomics · doi:10.3897/mbmg.2.23297 · Cited by 246
Asch, D. A., Sheils, N. E., Islam, M. N., Chen, Y., Werner, R. M., Buresh, J., & Doshi, J. A. (2021) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2020.8193 · Cited by 245
Ninh, N., Thissen, J., Collette, L., Gerard, G., Khoi, H., & Ketelslegers, J. (1996) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/63.4.514 · Cited by 239
Angerer, P., Störk, S., Kothny, W., Schmitt, P., & von Schacky, C. (2001) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/01.atv.21.2.262 · Cited by 240
On the statistical reliability of letter-chart visual acuity measurements.
Arditi, A. R., & Cagenello, R. (1993) · PubMed · Cited by 239
Della Rocca, G., Costa, M. G., Pompei, L., Coccia, C., & Pietropaoli, P. (2002) · British Journal of Anaesthesia · doi:10.1093/bja/88.3.350 · Cited by 239
Bekkers, J. E. J., de Windt, T. S., Raijmakers, N. J. H., Dhert, W. J. A., & Saris, D. B. F. (2009) · Osteoarthritis and Cartilage · doi:10.1016/j.joca.2009.04.019 · Cited by 239
Lee, K. H., Goo, J. M., Park, S. J., Wi, J. Y., Chung, D. H., Go, H., Park, H. S., Park, C. M., & Lee, S. M. (2014) · Journal of Thoracic Oncology · doi:10.1097/jto.0000000000000019 · Cited by 238
Retinal vascular tree morphology: a semi-automatic quantification
Martinez-Perez, M. E., Highes, A. D., Stanton, A. V., Thorn, S. A., Chapman, N., Bharath, A. A., & Parker, K. H. (2002) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2002.800789 · Cited by 241
Comparison of methods for the rapid laboratory assessment of children with malaria.
Planche, T., Krishna, S., Kombila, M., Engel, K., Faucher, J. F., Ngou-Milama, E., & Kremsner, P. G. (2001) · The American journal of tropical medicine and hygiene · doi:10.4269/ajtmh.2001.65.599 · Cited by 242
Earthman, C. P. (2015) · Journal of Parenteral and Enteral Nutrition · doi:10.1177/0148607115595227 · Cited by 234
Lombard, M. J., Steyn, N. P., Charlton, K. E., & Senekal, M. (2015) · Nutrition Journal · doi:10.1186/s12937-015-0027-y · Cited by 238
Cunha, R. S., Pannier, B., Benetos, A., Siché, J.-P., London, G. M., Mallion, J. M., & Safar, M. E. (1997) · Journal of Hypertension · doi:10.1097/00004872-199715120-00009 · Cited by 241
Messroghli, D. R., Plein, S., Higgins, D. M., Walters, K., Jones, T. R., Ridgway, J. P., & Sivananthan, M. U. (2006) · Radiology · doi:10.1148/radiol.2382041903 · Cited by 239
Increasing degrees of left ventricular filling impairment modulate left atrial function in humans
Prioli, A., Marino, P., Lanzoni, L., & Zardini, P. (1998) · The American Journal of Cardiology · doi:10.1016/s0002-9149(98)00452-4 · Cited by 237
Iversen, P. W., Eastwood, B. J., Sittampalam, G. S., & Cox, K. L. (2006) · SLAS Discovery · doi:10.1177/1087057105285610 · Cited by 237
Hoit, B. D., Khoury, S. F., Kranias, E. G., Ball, N., & Walsh, R. A. (1995) · Circulation Research · doi:10.1161/01.res.77.3.632 · Cited by 241
Freckmann, G., Schmid, C., Baumstark, A., Pleus, S., Link, M., & Haug, C. (2012) · Journal of Diabetes Science and Technology · doi:10.1177/193229681200600510 · Cited by 237
Lobbes, M. B. I., Prevos, R., Smidt, M., Tjan-Heijnen, V. C. G., van Goethem, M., Schipper, R., Beets-Tan, R. G., & Wildberger, J. E. (2013) · Insights into Imaging · doi:10.1007/s13244-013-0219-y · Cited by 237
Standardization of Bone Mineral Density at Femoral Neck, Trochanter and Ward's Triangle
Lu, Y., Fuerst, T., Hui, S., & Genant, H. K. (2001) · Osteoporosis International · doi:10.1007/s001980170087 · Cited by 237
Helbing, W. A., Niezen, R. A., Le Cessie, S., Van Der Geest, R. J., Ottenkamp, J., & De Roos, A. (1996) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(96)00387-7 · Cited by 239
Maximal values of sniff nasal inspiratory pressure in healthy subjects.
Uldry, C., & Fitting, J. W. (1995) · Thorax · doi:10.1136/thx.50.4.371 · Cited by 239
Aldehydes in Exhaled Breath Condensate of Patients with Chronic Obstructive Pulmonary Disease
Corradi, M., Rubinstein, I., Andreoli, R., Manini, P., Caglieri, A., Poli, D., Alinovi, R., & Mutti, A. (2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200210-1253oc · Cited by 242
Body size and composition in Polynesians
Swinburn, B., Ley, S., Carmichael, H., & Plank, L. (1999) · International Journal of Obesity · doi:10.1038/sj.ijo.0801053 · Cited by 241
Pitta, F., Troosters, T., Spruit, M. A., Decramer, M., & Gosselink, R. (2005) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2005.04.016 · Cited by 242
Determining Vitamin D Status: A Comparison between Commercially Available Assays
Snellman, G., Melhus, H., Gedeborg, R., Byberg, L., Berglund, L., Wernroth, L., & Michaëlsson, K. (2010) · PLoS ONE · doi:10.1371/journal.pone.0011555 · Cited by 236
Non‐parametric combination and related permutation tests for neuroimaging
Winkler, A. M., Webster, M. A., Brooks, J. C., Tracey, I., Smith, S. M., & Nichols, T. E. (2016) · Human Brain Mapping · doi:10.1002/hbm.23115 · Cited by 245
Accuracy of the Actiheart for the assessment of energy expenditure in adults
Crouter, S. E., Churilla, J. R., & Bassett, D. R. (2008) · European Journal of Clinical Nutrition · doi:10.1038/sj.ejcn.1602766 · Cited by 236
Smartwatch-Based Wearable EEG System for Driver Drowsiness Detection
Li, G., Lee, B.-L., & Chung, W.-Y. (2015) · IEEE Sensors Journal · doi:10.1109/jsen.2015.2473679 · Cited by 236
Antigen Assay with the Potential To Aid in Diagnosis of Blastomycosis
Durkin, M., Witt, J., LeMonte, A., Wheat, B., & Connolly, P. (2004) · Journal of Clinical Microbiology · doi:10.1128/jcm.42.10.4873-4875.2004 · Cited by 240
Liu, Y., Spulber, G., Lehtimäki, K. K., Könönen, M., Hallikainen, I., Gröhn, H., Kivipelto, M., Hallikainen, M., Vanninen, R., & Soininen, H. (2011) · Neurobiology of Aging · doi:10.1016/j.neurobiolaging.2009.10.006 · Cited by 236
Petersen, E. T., Mouridsen, K., & Golay, X. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2009.07.068 · Cited by 239
Soft Wearable Pressure Sensors for Beat‐to‐Beat Blood Pressure Monitoring
Kim, J., Chou, E., Le, J., Wong, S., Chu, M., & Khine, M. (2019) · Advanced Healthcare Materials · doi:10.1002/adhm.201900109 · Cited by 238
Noninvasive measurement of human forearm oxygen consumption by near infrared spectroscopy
De Blasi, R. A., Cope, M., Elwell, C., Safoue, F., & Ferrari, M. (1993) · European Journal of Applied Physiology and Occupational Physiology · doi:10.1007/bf00377698 · Cited by 238
Maqbool, S., Parkman, H. P., & Friedenberg, F. K. (2009) · Digestive Diseases and Sciences · doi:10.1007/s10620-009-0899-9 · Cited by 235
Reant, P., Labrousse, L., Lafitte, S., Bordachar, P., Pillois, X., Tariosse, L., Bonoron-Adele, S., Padois, P., Deville, C., Roudaut, R., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.07.088 · Cited by 237
Corneal Deformation Measurement Using Scheimpflug Noncontact Tonometry
Hon, Y., & Lam, A. K. C. (2013) · Optometry and Vision Science · doi:10.1097/opx.0b013e318279eb87 · Cited by 235
Zwart, J.-A., Dyb, G., Holmen, T., Stovner, L., & Sand, T. (2004) · Cephalalgia · doi:10.1111/j.1468-2982.2004.00680.x · Cited by 235
Serum surfactant protein D is steroid sensitive and associated with exacerbations of COPD
Lomas, D. A., Silverman, E. K., Edwards, L. D., Locantore, N. W., Miller, B. E., Horstman, D. H., & Tal-Singer, R. (2009) · European Respiratory Journal · doi:10.1183/09031936.00156508 · Cited by 235
Test–retest: Agreement or reliability?
Berchtold, A. (2016) · Methodological Innovations · doi:10.1177/2059799116672875 · Cited by 226
Markl, M., Wegent, F., Zech, T., Bauer, S., Strecker, C., Schumacher, M., Weiller, C., Hennig, J., & Harloff, A. (2010) · Circulation: Cardiovascular Imaging · doi:10.1161/circimaging.110.958504 · Cited by 232
A Review of Calibration Transfer Practices and Instrument Differences in Spectroscopy
Workman, J. J. (2018) · Applied Spectroscopy · doi:10.1177/0003702817736064 · Cited by 223
Noninvasive Monitoring of Cardiac Output in Critically Ill Patients Using Transesophageal Doppler
Valtier, B., Cholley, B., Belot, J.-P., Coussaye, J.-E. D. L., Matéo, J., & Payen, D. M. (1998) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.158.1.9707031 · Cited by 235
Association between plaque instability, angiogenesis and symptomatic carotid occlusive disease
Mofidi, R., Crotty, T. B., McCarthy, P., Sheehan, S. J., Mehigan, D., & Keaveny, T. V. (2001) · Journal of British Surgery · doi:10.1046/j.0007-1323.2001.01823.x · Cited by 235
Boot, A., Bouquet, J., de Ridder, M., Krenning, E., & de Muinck Keizer-Schrama, S. (1997) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/66.2.232 · Cited by 239
Detecting axon damage in spinal cord from a mouse model of multiple sclerosis
Kim, J. H., Budde, M. D., Liang, H.-F., Klein, R. S., Russell, J. H., Cross, A. H., & Song, S.-K. (2006) · Neurobiology of Disease · doi:10.1016/j.nbd.2005.09.009 · Cited by 235
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.