The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Electrospray interface for liquid chromatographs and mass spectrometers
Open accessAbstract
ADVERTISEMENT RETURN TO ISSUEPREVArticleNEXTElectrospray interface for liquid chromatographs and mass spectrometersCraig M. Whitehouse, Robert N. Dreyer, Masamichi. Yamashita, and John B. FennCite this: Anal. Chem. 1985, 57, 3, 675–679Publication Date (Print):March 1, 1985Publication History Published online1 May 2002Published inissue 1 March 1985https://pubs.acs.org/doi/10.1021/ac00280a023https://doi.org/10.1021/ac00280a023research-articleACS PublicationsRequest reuse permissionsArticle Views3745Altmetric-Citations1219LEARN ABOUT THESE METRICSArticle Views are the COUNTER-compliant sum of full text article downloads since November 2008 (both PDF and HTML) across all institutions and individuals. These metrics are regularly updated to reflect usage leading up to the last few days.Citations are the number of other articles citing this article, calculated by Crossref and updated daily. Find more information about Crossref citation counts.The Altmetric Attention Score is a quantitative measure of the attention that a research article has received online. Clicking on the donut icon will load a page at altmetric.com with additional details about the score and the social media presence for the given article. Find more information on the Altmetric Attention Score and how the score is calculated. Share Add toView InAdd Full Text with ReferenceAdd Description ExportRISCitationCitation and abstractCitation and referencesMore Options Share onFacebookTwitterWechatLinked InRedditEmail Other access optionsGet e-Alertsclose Get e-Alerts
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrospray ion source. Another variation on the free-jet theme
Yamashita, M., & Fenn, J. B. (1984) · The Journal of Physical Chemistry · doi:10.1021/j150664a002 · Cited by 2,082
Self-citationDole, M., Mack, L. L., Hines, R. L., Mobley, R. C., Ferguson, L. D., & Alice, M. B. (1968) · The Journal of Chemical Physics · doi:10.1063/1.1670391 · Cited by 1,613
On the evaporation of small ions from charged droplets
Iribarne, J. V., & Thomson, B. A. (1976) · The Journal of Chemical Physics · doi:10.1063/1.432536 · Cited by 1,281
Thermospray interface for liquid chromatography/mass spectrometry
Blakley, C. R., & Vestal, M. L. (1983) · Analytical Chemistry · doi:10.1021/ac00255a036 · Cited by 651
Field induced ion evaporation from liquid surfaces at atmospheric pressure
Thomson, B. A., & Iribarne, J. V. (1979) · The Journal of Chemical Physics · doi:10.1063/1.438198 · Cited by 631
Negative ion production with the electrospray ion source
Yamashita, M., & Fenn, J. B. (1984) · The Journal of Physical Chemistry · doi:10.1021/j150664a046 · Cited by 581
Self-citationA new soft ionization technique for mass spectrometry of complex molecules
Blakley, C. R., Carmody, J. J., & Vestal, M. L. (1980) · Journal of the American Chemical Society · doi:10.1021/ja00538a050 · Cited by 275
Liquid chromatograph-mass spectrometer for analysis of nonvolatile samples
Blakley, C. R., Carmody, J. J., & Vestal, M. L. (1980) · Analytical Chemistry · doi:10.1021/ac50061a025 · Cited by 201
Atmospheric pressure ion evaporation-mass spectrometry
Iribarne, J. V., Dziedzic, P. J., & Thomson, B. A. (1983) · International Journal of Mass Spectrometry and Ion Physics · doi:10.1016/0020-7381(83)87009-0 · Cited by 136
Simons, D. S., Colby, B. N., & Evans, C. A. (1974) · International Journal of Mass Spectrometry and Ion Physics · doi:10.1016/0020-7381(74)85006-0 · Cited by 128
Cited by
Electrospray Ionization for Mass Spectrometry of Large Biomolecules
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1989) · Science · doi:10.1126/science.2675315 · Cited by 7,634
Self-citationNew developments in biochemical mass spectrometry: electrospray ionization
Smith, R. D., Loo, J. A., Edmonds, C. G., Barinaga, C. J., & Udseth, H. R. (1990) · Analytical Chemistry · doi:10.1021/ac00208a002 · Cited by 1,051
Electrospray: From ions in solution to ions in the gas phase, what we know now
Kebarle, P., & Verkerk, U. H. (2009) · Mass Spectrometry Reviews · doi:10.1002/mas.20247 · Cited by 905
Definitions of terms relating to mass spectrometry (IUPAC Recommendations 2013)
Murray, K. K., Boyd, R. K., Eberlin, M. N., Langley, G. J., Li, L., & Naito, Y. (2013) · Pure and Applied Chemistry · doi:10.1351/pac-rec-06-04-06 · Cited by 687
Towards single-molecule nanomechanical mass spectrometry
Naik, A. K., Hanay, M. S., Hiebert, W. K., Feng, X. L., & Roukes, M. L. (2009) · Nature Nanotechnology · doi:10.1038/nnano.2009.152 · Cited by 683
Banerjee, S., & Mazumdar, S. (2012) · International Journal of Analytical Chemistry · doi:10.1155/2012/282574 · Cited by 662
Covey, T. R., Bonner, R. F., Shushan, B. I., Henion, J., & Boyd, R. K. (1988) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290021111 · Cited by 593
The fundamental flaws of immunoassays and potential solutions using tandem mass spectrometry
Hoofnagle, A. N., & Wener, M. H. (2009) · Journal of Immunological Methods · doi:10.1016/j.jim.2009.06.003 · Cited by 561
Improved electrospray ionization interface for capillary zone electrophoresis-mass spectrometry
Smith, R. D., Barinaga, C. J., & Udseth, H. R. (1988) · Analytical Chemistry · doi:10.1021/ac00169a022 · Cited by 535
[21] Electrospray ionization mass spectrometry
Fred Banks, J., & Whitehouse, C. M. (1996) · Methods in Enzymology · doi:10.1016/s0076-6879(96)70023-x · Cited by 522
Self-citation[22] Electrospray ionization mass spectrometry
Edmonds, C. G., & Smith, R. D. (1990) · Methods in Enzymology · doi:10.1016/0076-6879(90)93430-s · Cited by 508
Top Down proteomics: Facts and perspectives
Catherman, A. D., Skinner, O. S., & Kelleher, N. L. (2014) · Biochemical and Biophysical Research Communications · doi:10.1016/j.bbrc.2014.02.041 · Cited by 507
“In many cases, liquid chromatography can often be coupled to electrospray ionization (ESI), proving an effective method for on-line analysis [14].”
BackgroundLiquid chromatography/mass spectrometry
Covey, T. R., Lee, E. D., Bruins, A. P., & Henion, J. D. (1986) · Analytical Chemistry · doi:10.1021/ac00127a001 · Cited by 469
Covey, T. R., Huang, E. C., & Henion, J. D. (1991) · Analytical Chemistry · doi:10.1021/ac00013a003 · Cited by 446
Mallet, C. R., Lu, Z., & Mazzeo, J. R. (2004) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1276 · Cited by 441
Analytical Chemistry of Fruit BioflavonoidsA Review
Robards, K., & Antolovich, M. (1997) · The Analyst · doi:10.1039/a606499j · Cited by 436
Enke, C. G. (1997) · Analytical Chemistry · doi:10.1021/ac970095w · Cited by 419
The gas-phase basicities and proton affinities of amino acids and peptides
Harrison, A. G. (1997) · Mass Spectrometry Reviews · doi:10.1002/(sici)1098-2787(1997)16:4<201::aid-mas3>3.0.co;2-l · Cited by 403
Deciphering Protein–Protein Interactions. Part I. Experimental Techniques and Databases
Shoemaker, B. A., & Panchenko, A. R. (2007) · PLoS Computational Biology · doi:10.1371/journal.pcbi.0030042 · Cited by 398
Capillary zone electrophoresis-mass spectrometry using an electrospray ionization interface
Smith, R. D., Olivares, J. A., Nguyen, N. T., & Udseth, H. R. (1988) · Analytical Chemistry · doi:10.1021/ac00156a013 · Cited by 393
Weighing Naked Proteins: Practical, High-Accuracy Mass Measurement of Peptides and Proteins
Chait, B. T., & Kent, S. B. H. (1992) · Science · doi:10.1126/science.1411504 · Cited by 393
Mass Spectrometry, Review of the Basics: Electrospray, MALDI, and Commonly Used Mass Analyzers
El-Aneed, A., Cohen, A., & Banoub, J. (2009) · Applied Spectroscopy Reviews · doi:10.1080/05704920902717872 · Cited by 386
Electrospray mass spectrometry applied to inorganic and organometallic chemistry
Colton, R., D'Agostino, A., & Traeger, J. C. (1995) · Mass Spectrometry Reviews · doi:10.1002/mas.1280140203 · Cited by 379
Mechanism of electrospray mass spectrometry. Electrospray as an electrolysis cell
Blades, A. T., Ikonomou, M. G., & Kebarle, P. (1991) · Analytical Chemistry · doi:10.1021/ac00019a009 · Cited by 364
LC/MS applications in drug development
Lee, M. S., & Kerns, E. H. (1999) · Mass Spectrometry Reviews · doi:10.1002/(sici)1098-2787(1999)18:3/4<187::aid-mas2>3.0.co;2-k · Cited by 339
Internal energy and fragmentation of ions produced in electrospray sources
Gabelica, V., & Pauw, E. D. (2005) · Mass Spectrometry Reviews · doi:10.1002/mas.20027 · Cited by 338
Studies of alkaline earth and transition metal M++ gas phase ion chemistry
Blades, A. T., Jayaweera, P., Ikonomou, M. G., & Kebarle, P. (1990) · The Journal of Chemical Physics · doi:10.1063/1.458360 · Cited by 332
An electrospray‐ionization mass spectrometer with new features
Chowdhury, S. K., Katta, V., & Chait, B. T. (1990) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290040305 · Cited by 323
Electrospray-ion spray: a comparison of mechanisms and performance
Ikonomou, M. G., Blades, A. T., & Kebarle, P. (1991) · Analytical Chemistry · doi:10.1021/ac00018a017 · Cited by 322
Recent advances in capillary electrophoresis/electrospray/mass spectrometry
Banks, J. F. (1997) · ELECTROPHORESIS · doi:10.1002/elps.1150181216 · Cited by 308
Castañeda, O., Sotolongo, V., Amor, A. M., Stöcklin, R., Anderson, A. J., Harvey, A. L., Engström, Å., Wernstedt, C., & Karlsson, E. (1995) · Toxicon · doi:10.1016/0041-0101(95)00013-c · Cited by 283
Atmospheric pressure chemical ionization mass spectrometry for analysis of lipids
Byrdwell, W. C. (2001) · Lipids · doi:10.1007/s11745-001-0725-5 · Cited by 279
Progress in monitoring, modeling and control of bioprocesses during the last 20 years
Schügerl, K. (2001) · Journal of Biotechnology · doi:10.1016/s0168-1656(00)00361-8 · Cited by 278
Effect of reducing disulfide-containing proteins on electrospray ionization mass spectra
Loo, J. A., Edmonds, C. G., Udseth, H. R., & Smith, R. D. (1990) · Analytical Chemistry · doi:10.1021/ac00206a009 · Cited by 274
Sonic Spray Ionization Method for Atmospheric Pressure Ionization Mass Spectrometry
Hirabayashi, A., Sakairi, M., & Koizumi, H. (1994) · Analytical Chemistry · doi:10.1021/ac00096a025 · Cited by 273
Frontiers in the spectroscopy of mass-selected molecular ions
Duncan, M. A. (2000) · International Journal of Mass Spectrometry · doi:10.1016/s1387-3806(00)00366-3 · Cited by 270
Electrospray Ionization High-Field Asymmetric Waveform Ion Mobility Spectrometry−Mass Spectrometry
Purves, R. W., & Guevremont, R. (1999) · Analytical Chemistry · doi:10.1021/ac981380y · Cited by 265
Brügger, B. (2014) · Annual Review of Biochemistry · doi:10.1146/annurev-biochem-060713-035324 · Cited by 264
Atmospheric pressure ion sources
Covey, T. R., Thomson, B. A., & Schneider, B. B. (2009) · Mass Spectrometry Reviews · doi:10.1002/mas.20246 · Cited by 264
Broeckling, C. D., Afsar, F. A., Neumann, S., Ben-Hur, A., & Prenni, J. E. (2014) · Analytical Chemistry · doi:10.1021/ac501530d · Cited by 262
Tang, L., & Kebarle, P. (1991) · Analytical Chemistry · doi:10.1021/ac00023a009 · Cited by 260
Sabino, A. A., Machado, A. H. L., Correia, C. R. D., & Eberlin, M. N. (2004) · Angewandte Chemie International Edition · doi:10.1002/anie.200353076 · Cited by 254
Time-of-flight mass spectrometry (concepts, achievements, and prospects)
Mamyrin, B. A. (2001) · International Journal of Mass Spectrometry · doi:10.1016/s1387-3806(00)00392-4 · Cited by 251
Surfactant effects on protein structure examined by electrospray ionization mass spectrometry
Loo, R. R. O., Dales, N., & Andrews, P. C. (1994) · Protein Science · doi:10.1002/pro.5560031109 · Cited by 184
Staphyloferrin A: a structurally new siderophore from staphylococci
KONETSCHNY‐RAPP, S., JUNG, G., MEIWES, J., & ZÄHNER, H. (1990) · European Journal of Biochemistry · doi:10.1111/j.1432-1033.1990.tb19094.x · Cited by 160
Ugrin, S. A., English, A. M., Syka, J. E. P., Bai, D. L., Anderson, L. C., Shabanowitz, J., & Hunt, D. F. (2019) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-019-02290-8 · Cited by 44
Mokaddem, M., Gareil, P., Belgaied, J., & Varenne, A. (2009) · ELECTROPHORESIS · doi:10.1002/elps.200800480 · Cited by 45
Physical analysis of virus particles using electrospray differential mobility analysis
Pease, L. F. (2012) · Trends in Biotechnology · doi:10.1016/j.tibtech.2011.11.004 · Cited by 43
Boley, D. A., Zhang, Z., & Dovichi, N. J. (2017) · Journal of Chromatography A · doi:10.1016/j.chroma.2017.07.022 · Cited by 29
Metadata
- Authors
- Whitehouse, C. M., Dreyer, R. N., Yamashita, M., & Fenn, J. B.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1985-03-01
- Volume
- 57
- Issue
- 3
- Pages
- 675-679
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2000983103
- Cited by
- 1,512
- References
- 11
- FWCI
- 9.93
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.