Cited by 14Per- and polyfluoroalkyl substances researchUrban Stormwater Management SolutionsPharmaceutical and Antibiotic Environmental Impacts

Using a Time-of-Travel Sampling Approach to Quantify Per- and Polyfluoroalkyl Substances (PFAS) Stream Loading and Source Inputs in a Mixed-Source, Urban Catchment

Open access
Woodward, Emily E., Senior, Lisa A., Fleck, Jacob A., Barber, Larry B., Hansen, Angela M., Duris, Joseph W.·2024·ACS ES&T Water

Abstract

High Resolution Image Download MS PowerPoint Slide Understanding per- and polyfluoroalkyl substances (PFAS) mass distribution in surface and groundwater systems can support source prioritization, load reduction, and water management. Thirteen sites within an urban catchment were sampled utilizing a time-of-travel sampling approach to minimize the influence of subdaily fluctuations in mass from PFAS point sources and to quantify PFAS and ancillary chemical loads from various PFAS sources. A larger increase in perfluoroalkyl sulfonate (PFSA) loads (8 to 11 μg/s, up to 618%) than in perfluoroalkyl carboxylate (PFCA) loads (no change to 3.4 μg/s, up to 122%) was observed at sites below tributaries influenced by military bases with known groundwater discharge. Point discharges from two sewage treatment plants (STPs) resulted in increases in PFCA and PFSA loads that were similar (6 and 10 μg/s respectively) below the first STP and greater for PFCA compared to PFSA loads (23 and 13 μg/s respectively) below the second STP. Overall, percent increases in total PFAS load ranged from 20 to 277% for military base inputs and 44 to 77% for STP inputs. A focus catchment that represents only 14% (76.9 km 2 ) of the drainage area at the most downstream site (544 km 2 ) accounted for about 70% of PFSA and 40% of PFCA loads observed at the most downstream site. Results show that by using a time-of-travel sampling approach in mixed, urban settings with several PFAS sources, it is possible to quantify stream loads from individual PFAS sources, thereby improving source attribution and providing actionable data for water-resource managers.

AI snapshot

Written from the paper’s full text.

TL;DR

A time-of-travel sampling approach was used at 13 sites in an urbanized Neshaminy Creek catchment to quantify PFAS stream loads and attribute inputs from military-base tributaries and sewage treatment plants. The study found larger PFSA load increases below military-base-influenced tributaries and mixed PFCA/PFSA increases below STPs, with a small focus reach accounting for most downstream PFSA load.

Key findings

  • Military-base-influenced tributary inputs produced PFSA load increases of 8.0, 6.8, and 11 μg/s at site pairs 2–3, 5–6, and 9–10, compared with PFCA load differences of 3.4, no difference, and 2.9 μg/s; percent increases in total PFAS load ranged from 20 to 277% for military base inputs.
  • STP inputs increased PFCA and PFSA loads similarly below PCSTP (6.0 μg/s PFCA, 75%; 10 μg/s PFSA, 76%) but more for PFCA below LCSTP (23 μg/s PFCA, 76%; 13 μg/s PFSA, 27%); STP-related percent increases in total PFAS load ranged from 44 to 77%.
  • The focus catchment (76.9 km², about 14% of the 544 km² drainage area at the most downstream site) accounted for about 70% of PFSA and 40% of PFCA loads at the most downstream site; total PFAS load increased from 118 μg/s at site 12 to 223 μg/s at site 13.
  • PCA explained 75% of variability in the first two components (PC1 50%, PC2 25%) and separated municipal wastewater indicators from a mixture of wastewater, military base, and possible industrial sources.

Methods

  • Thirteen sites in the Neshaminy Creek watershed (600 km²), southeastern Pennsylvania, were sampled November 16–18, 2021, under approximate base-flow conditions (3 days after ~6 mm precipitation) and near long-term median streamflow; 12 sites were sampled on day one in the focus reach, and site 13 was sampled on day three.
  • Samples were collected using a time-of-travel approach so the same parcel of water was targeted at each site, with discrete surface-water samples collected by equal-width, depth-integrated USGS protocols; analyses included 40 target PFAS by EPA Method 1633, TOPA, DOC, optical properties, VOCs, major and trace elements, and pharmaceuticals.
  • Instantaneous streamflow was measured at each site (FlowTracker at sites 1–12; USGS streamgage at site 13) and used to convert concentrations to loads; multivariate PCA used 31 normalized variables in R.

Limitations

  • The paper states that study design limitations prevented targeting specific source inputs between sites 12 and 13, and that exact apportionment between sites would require detailed flow models or measurements and precise source-loading information.
  • The paper notes that STP diurnal flow variability could account for an estimated 12–30% variation in PFAS load from PCSTP and 33–82% from LCSTP assuming constant PFAS concentration, and that streamflow losses were within measurement uncertainty but may reflect pumping and complex groundwater/surface-water interactions.
  • The paper states that 6:2 FTS mass decreased between sites 7–9 (−0.48 μg/s, −31%), indicating possible nonconservative transport, but the transformation pathway is uncertain; it also notes that larger catchments with multiple sources can be more challenging and that groundwater flux could be missed.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.1021/acsestwater.4c00288

Cites

52 of 52 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Claims the paper makes

8 of 61 cited sources checked · 6 supported · 0 flagged · accuracy not yet measured

  • Premisecitation

    With many potential source inputs, it is difficult to identify the origin of PFAS in a water sample.

    “With many potential source inputs, it is difficult to identify the origin of PFAS in a water sample.”
    Quote in the paperSubstantial claim1 of 2 sources checked
    • cites [3] source
    • cites [6] source
  • Premisecitation

    Evaluation of PFAS loads from different sources in a stream can be challenging in systems with wastewater treatment plant effluent inputs that produce subdaily fluctuations in load and systems underlain by heavily pumped fractured rock aquifers.

    “Evaluation of PFAS loads from different sources in a stream can be challenging in systems with wastewater treatment plant effluent inputs that produce subdaily fluctuations in load 12 and systems underlain by heavily pumped fractured rock aquifers.11”
    Quote in the paperSubstantial claim1 of 2 sources checked
    • cites [12] source

      Section 3.3 (page unavailable) reports that PFAS input from a wastewater treatment plant varied across sampling days and that this variability complicated load estimation. It does not establish subdaily fluctuations. The fractured-rock-aquifer clause carries a different citation and is not attributed to this paper. (LLM, conf=0.84)

      Experimental — accuracy not yet measured
    • cites [11] source
  • Interpretationcitation

    The observed sulfonate signature, especially high concentrations of PFHxS and PFOS, can be characteristic of historic AFFF use.

    “This type of observed sulfonate signature, especially high concentrations of PFHxS and PFOS, can be characteristic of historic AFFF use.”
    Quote in the paperSubstantial claim2 of 3 sources checked
    • cites [29] source
    • cites [30] source
    • cites [31] source
  • Findingown data

    A focus catchment representing only 14% (76.9 km2) of the drainage area at the most downstream site (544 km2) accounted for about 70% of PFSA and 40% of PFCA loads observed at the most downstream site.

    “A focus catchment that represents only 14% (76.9 km 2 ) of the drainage area at the most downstream site (544 km 2 ) accounted for about 70% of PFSA and 40% of PFCA loads observed at the most downstream site.”
    Quote in the paperSubstantial claim
  • Findingown data

    Increases in PFSA load between the three site groupings that isolated military base inputs (2-3, 5-6, and 9-10) were 8.0, 6.8, and 11 μg/s.

    “Increases in PFSA load between the three site groupings that isolated military base inputs (2-3, 5-6, and 9-10) were 8.0, 6.8, and 11 μg/s.”
    Quote in the paperSubstantial claim
  • Classified as probably not a substantial claim. 27
  • May combine two claims. 51
  • The quote only partly states this claim. 1
  • Probably not a substantial claim: may not pass S2 (checkable).

    Premisecitation

    There is a critical need for catchment-scale PFAS loading data.

    “One study went as far as to state that there is a critical need for this type of catchment-scale PFAS loading data.16”
    Quote in the paperNot a substantial claim1 of 1 sources checked
  • Probably not a substantial claim: may not pass S3 (load-bearing).

    Premisecitation

    Multivariate analyses have been used to establish PFAS source signatures and distinguish PFAS source inputs in surface water.

    “Multivariate analyses have been used to establish PFAS source signatures and distinguish PFAS source inputs in surface water.”
    Quote in the paperNot a substantial claim2 of 3 sources checked
    • cites [7] source
    • cites [8] source
    • cites [9] source
  • Probably not a substantial claim: may not pass S3 (load-bearing).

    Interpretationreasoning

    Tributaries that join Little Neshaminy Creek between sites 11-12 could also be a potential source of PFDA in the system.

    “Tributaries that join Little Neshaminy Creek between sites 11-12 could also be a potential source of PFDA in the system, although several studies have observed PFDA in STP outfalls.”
    Quote in the paperNot a substantial claim1 of 3 sources checked
    • cites [44] source
    • cites [45] source

      The Results and discussion section, “PFAS in WWTP matrices” (page unavailable), reports a significant increase in PFDA between influent and final effluent at Australian wastewater treatment plants. It does not address Little Neshaminy Creek, tributaries between sites 11–12, or whether those tributaries could supply PFDA; searches for those locations and for tributary sources found no relevant passage. (LLM, conf=0.78)

      Experimental — accuracy not yet measured
    • cites [46] source
  • May combine two claims.

    Findingown data

    Diurnal fluctuations from STPs could account for an estimated 12-30% diurnal variation in PFAS load from PCSTP and an estimated 33-82% variation in load from LCSTP, assuming constant PFAS concentration from the STP.

    “Diurnal fluctuations from STPs could account for an estimated 12-30% diurnal variation in PFAS load from PCSTP and an estimated 33-82% variation in load from LCSTP, assuming constant PFAS concentration from the sewage treatment plant (Table S6).”
    Quote in the paperNot a substantial claim
    • The authors state this as an assumption: PFAS concentration from the sewage treatment plant is constant for the diurnal variation estimate.
  • May combine two claims.

    Findingown data

    Point discharges from two sewage treatment plants resulted in similar PFCA and PFSA load increases (6 and 10 μg/s respectively) below the first STP and greater PFCA than PFSA load increases (23 and 13 μg/s respectively) below the second STP.

    “Point discharges from two sewage treatment plants (STPs) resulted in increases in PFCA and PFSA loads that were similar (6 and 10 μg/s respectively) below the first STP and greater for PFCA compared to PFSA loads (23 and 13 μg/s respectively) below the second STP.”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Findingown data

    Overall percent increases in total PFAS load ranged from 20 to 277% for military base inputs and 44 to 77% for STP inputs.

    “Overall, percent increases in total PFAS load ranged from 20 to 277% for military base inputs and 44 to 77% for STP inputs.”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Findingown data

    Under November 2021 near-average conditions, percent increases in total PFAS loads between sites 4-5 and 12-13 ranged from 44 to 77% and increases of streamflow ranged from 36 to 83%.

    “Under the November 2021 near-average conditions, the relative effects of STP effluent (assumed as a constant input) are shown as percent increases in loads and streamflow between sites 4-5 and 12-13 in Table S7, with increases of total PFAS loads ranging from 44 to 77% and increases of streamflow ranging from 36 to 83%.”
    Quote in the paperSubstantial claim
    • The authors state this as an assumption: STP effluent is a constant input for the percent increases in loads and streamflow between sites 4-5 and 12-13.
  • May combine two claims.

    Findingown data

    Measured streamflow generally increased in the downstream direction throughout the focus reach, reflecting inflows from tributaries, point sources, and groundwater discharge; however, there were two instances of measured streamflow loss between upstream and downstream sites.

    “Measured streamflow generally increased in the downstream direction throughout the focus reach, reflecting inflows from tributaries, point sources, and groundwater discharge; however, there were two instances of measured streamflow loss between upstream and downstream sites (Table S1).”
    Quote in the paperNot a substantial claim
  • Probably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.

    Findingown data

    Daily fluctuations of about 0.5 ft3/s and 6 to 8 ft3/s are commonly observed at gages below Park Creek Sewage Treatment Plant and Log College Sewage Treatment Plant, respectively.

    “Daily fluctuations of about 0.5 ft 3 /s and 6 to 8 ft 3 /s are commonly observed at gages below Park Creek Sewage Treatment Plant (PCSTP) and Log College Sewage Treatment Plant (LCSTP), respectively.”
    Quote in the paperNot a substantial claim
  • Probably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.

    Findingown data

    Streamflow losses were measured between site 1 (3.21 ft3/s) and site 2 (3.06 ft3/s) and between site 5 (6.99 ft3/s) and site 6 (6.44 ft3/s).

    “Losses were measured between site 1 (3.21 ft 3 /s) and site 2 (3.06 ft 3 /s) and between site 5 (6.99 ft 3 /s) and site 6 (6.44 ft 3 /s) (Figure S2).”
    Quote in the paperNot a substantial claim
  • May combine two claims.

    Findingown data

    Of the 40 target PFAS measured, 13 were detected: seven perfluoroalkyl carboxylates, five perfluoroalkyl sulfonates, and one perfluoroalkyl acid precursor.

    “Of the 40 target PFAS measured, 19 13 were detected: seven perfluoroalkyl carboxylates (PFCA), five perfluoroalkyl sulfonates (PFSA), and one perfluoroalkyl acid (PFAA) precursor (Figure 2, Table S1).”
    Quote in the paperNot a substantial claim
  • May combine two claims.

    Findingown data

    Around 70% of the total PFSA load at site 13 was derived from the focus catchment including sites 1 to 12, indicating only 30% of the total PFSA load at site 13 is derived from other sources in the other catchments.

    “In contrast, around 70% of the total PFSA load at site 13 was derived from the focus catchment including sites 1 to 12, indicating only 30% of the total PFSA load at site 13 is derived from other sources in the other catchments (Figure 3B).”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Findingown data

    Input from PCSTP and any other potential unidentified sources between sites 4 and 5 increased PFCA loads by 6.0 μg/s (75%) and PFSA loads by 10 μg/s (76%).

    “The input from PCSTP and any other potential, unidentified sources between sites 4 and 5 increased PFCA loads by 6.0 μg/s (75%) and PFSA loads by 10 μg/s (76%) whereas the input from LCSTP and other potential unidentified sources between sites 11 and 12 increased PFCA loads by 23 μg/s (76%) and PFSA loads by only 13 μg/s (27%) (Table 1; Table S7).”
    Quote in the paperSubstantial claim
  • Probably not a substantial claim: may not pass S3 (load-bearing).

    Findingown data

    Stream samples analyzed for pharmaceutical compounds had 50 of 113 analytes detected at one or more sites.

    “Stream samples collected and analyzed for pharmaceutical compounds (to aid in source attribution) had numerous detections, with 50 of 113 analytes detected at one or more sites (Figure S4; Table S1).”
    Quote in the paperNot a substantial claim
  • May combine two claims.

    Findingnone given

    Reported monthly average flow from the STP effluents represents 30% and 24% of the measured streamflow downstream of the LCSTP and PCSTP outfalls, respectively, on the day of sampling.

    “The reported monthly average flow from the STP effluents represents 30% and 24% of the measured streamflow downstream of the LCSTP and PCSTP outfalls, respectively, on the day of sampling.”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Findingown data

    Around 40% of the total PFCA load at site 13 was derived from the focus catchment that includes sites 1 through 12, indicating about 60% of the total PFCA load at site 13 is coming from other sources in the other stream catchments that were not specifically targeted.

    “Around 40% of the total PFCA load at site 13 was derived from the focus catchment that includes sites 1 through 12, indicating ∼60% of the total PFCA load at site 13 is coming from other sources in the other stream catchments that were not specifically targeted (Figure 3A).”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Findingcitation

    Percent mass increases of 6:2 FTS occurred between sites 4-5, 5-6, and 9-10, all downstream of STP or military base inputs.

    “Percent mass increases of 6:2 FTS occurred between sites 4-5, 5-6, and 9-10, all downstream of STP or military base inputs, both of which are recognized potential sources of 6:2 FTS. 32,40”
    Quote in the paperSubstantial claim0 of 2 sources checked
    • cites [32] source
    • cites [40]

      Couldn’t be matched to a paper in Crossref, so it can’t be checked.

  • May combine two claims.

    Findingown data

    PC2 separated the anthropogenic end of PC1 into two groupings: municipal wastewater indicators (quadrant 4) and a mixture of wastewater, military base sources, and possible industrial sources including a source correlated with the VOC n-pentanal along PC2 (quadrant 3).

    “PC2 separated the anthropogenic end of PC1 into two groupings: 1) municipal wastewater indicators (quadrant 4) and 2) a mixture of wastewater, military base sources, and possible industrial sources including a source correlated with the VOC, n-pentanal along PC2 (quadrant 3).”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Findingown data

    The total PFAS load at site 12 was 118 μg/s and at site 13 was 223 μg/s, representing an approximately 2-fold increase in total PFAS load from the other catchments.

    “The total PFAS load at site 12 was 118 μg/s and at site 13 was 223 μg/s, representing an ∼2× increase in total PFAS load from the other catchments, assuming conservative transport and no loss to groundwater/surface water interactions (Figure 2).”
    Quote in the paperSubstantial claim
    • The authors state this as an assumption: Transport from site 12 to site 13 is conservative and there is no loss to groundwater/surface water interactions.
  • May combine two claims.

    Findingcitation

    Reported monthly average discharge for November 2021 was 8.51 ft3/s for LCSTP and 1.65 ft3/s for PCSTP.

    “Discharged effluent fluxes typically were greater at LCSTP than PCSTP; reported monthly average discharge for November 2021 was 8.51 ft 3 /s for LCSTP and 1.65 ft 3 /s for PCSTP.48”
    Quote in the paperSubstantial claim0 of 1 sources checked
    • cites [48] source
  • May combine two claims.

    Findingown data

    The highest loading variables for PC2 were n-pentanal (-), SUV254 (-), Flr_D:C (-), Gd (+), B (+), and certain PFAS (-), predominately PFSA compounds.

    “The highest loading variables for PC2 were n-pentanal (-), SUV254 (-), Flr_D:C (-), Gd (+), B (+), and certain PFAS (-), predominately PFSA compounds.”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Findingown data

    An increase in flow from site 6 to 7 of 1.5 ft3/s (23%) was measured that was not attributable to any known point sources.

    “Supporting this observation, an increase in flow from site 6 to 7 of 1.5 ft 3 /s (23%) (Table 1; Figure S2; Table S7) was measured that was not attributable to any known point sources, indicating a potential contribution of groundwater flow to the stream reach.”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Findingnone given

    Further downstream, LCSTP and other potential sources contributed a similar array of PFAS as PCSTP, except for the absence of 6:2 FTS and including the presence of PFDA.

    “Further downstream, LCSTP and other potential sources contributed a similar array of PFAS as PCSTP, except for the absence of 6:2 FTS and including the presence of PFDA.”
    Quote in the paperNot a substantial claim
  • May combine two claims.

    Findingown data

    PC1 alone explained 50% of the variation and was generally separated along a gradient across optical properties from natural organic matter indicators to anthropogenic organic matter indicators and contaminant concentrations.

    “PC1 alone explained 50% of the variation and was generally separated along a gradient across optical properties from natural organic matter indicators (left of the axis) to optical properties from anthropogenic organic matter indicators and contaminant concentrations (right of the axis).”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Findingown data

    Input from LCSTP and other potential unidentified sources between sites 11 and 12 increased PFCA loads by 23 μg/s (76%) and PFSA loads by only 13 μg/s (27%).

    “The input from PCSTP and any other potential, unidentified sources between sites 4 and 5 increased PFCA loads by 6.0 μg/s (75%) and PFSA loads by 10 μg/s (76%) whereas the input from LCSTP and other potential unidentified sources between sites 11 and 12 increased PFCA loads by 23 μg/s (76%) and PFSA loads by only 13 μg/s (27%) (Table 1; Table S7).”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Findingown data

    Measured streamflow on the day of sampling indicates that actual STP effluent flows (estimated by downstream site flow minus upstream site flow) were greater than reported monthly average values, representing closer to 45% (12.9 ft3/s) and 26% (1.85 ft3/s) of streamflow downstream from LCSTP and PCSTP, respectively.

    “However, measured streamflow on the day of sampling (Table S1) indicates that the actual STP effluent flows (estimated by the downstream site flow minus the upstream site flow) were greater than reported monthly average values, representing closer to 45% (12.9 ft 3 /s) and 26% (1.85 ft 3 /s) of the streamflow downstream from LCSTP and PCSTP, respectively.”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Findingown data

    Pharmaceutical loads were variable but reflected two main point sources, with large load increases computed downstream of STP inputs followed by decreases in downstream loads of some compounds.

    “Pharmaceutical loads were variable but reflected two main point sources, with large load increases computed downstream of STP inputs followed by decreases in downstream loads of some compounds indicating potential nonconservative transport and/or time-varying composition of effluent.”
    Quote in the paperNot a substantial claim
  • May combine two claims.

    Findingown data

    The first detection of 6:2 fluorotelomer sulfonate occurred downstream from PCSTP, and the first detection of perfluorodecanoate occurred downstream from LCSTP.

    “The first detection of two additional PFAS occurred downstream from the STPs: 6:2 fluorotelomer sulfonate (6:2 FTS; possible sources include AFFF and STP effluent) occurred downstream from PCSTP, and perfluorodecanoate (PFDA; long chain PFCA, wetting agent, flame retardant, consumer products like fabrics and cookware) 39 occurred downstream from LCSTP (Figure 2).”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Findingown data

    Pharmaceutical-compound load increases were up to 2 orders of magnitude higher than PFAS load increases between sampling sites, with load differences most pronounced downstream of LCSTP but also observed downstream of PCSTP.

    “Pharmaceutical-compound load increases were up to 2 orders of magnitude higher than PFAS load increases between sampling sites (mass/time), with load differences most pronounced downstream of LCSTP but also observed downstream of PCSTP; direct human use contributes these compounds to wastewater (Figure S4).”
    Quote in the paperNot a substantial claim
  • May combine two claims.

    Findingown data

    Increases in PFAS concentrations occurred between sites 4 and 5, but the largest concentration increases occurred for metformin, fexofenadine, Gd, B, and Zn, consistent with wastewater effluent input.

    “Increases in PFAS concentrations occurred between these two sites, but the largest concentration increases occurred for metformin, fexofenadine, Gd, B, and Zn, which are consistent with wastewater effluent input (Table S1).[52][53][54][55]”
    Quote in the paperSubstantial claim0 of 1 sources checked
    • cites [52][53][54][55]

      Couldn’t be matched to a paper in Crossref, so it can’t be checked.

  • Probably not a substantial claim: may not pass S3 (load-bearing).

    Findingown data

    The first two PCs account for 75% of variability in the data set.

    “The first two PCs account for 75% of variability in the data set.”
    Quote in the paperNot a substantial claim
  • May combine two claims.

    Findingown data

    PFPeA plotted toward the wastewater grouping and PFNA plotted toward n-pentanal in the PCA.

    “Of the PFAS compounds, PFPeA plotted toward the wastewater grouping and PFNA plotted toward the compound n-pentanal.”
    Quote in the paperSubstantial claim
  • The quote only partly states this claim.

    Findingown data

    Sites 8 and 13 are linked to numerous potential PFAS sources including metal manufacturing and plating, plastics and resins, paints and coatings, and more diffuse STPs in the upstream catchments.

    “Sites 8 and 13, though plotting more toward the”
    Quote in the paperNot a substantial claim
  • Classified as probably not a substantial claim.

    Premisecitation

    A time-of-travel approach that tracks a parcel of surface water as it moves, sampling and measuring sites directly upstream and downstream of PFAS point sources and tributary inputs, is one technique to quantify chemical loading from sources.

    “One technique to quantify chemical loading from sources is to use a time-of-travel approach that tracks a parcel of surface water as it moves, sampling and measuring sites directly upstream and downstream of PFAS point sources and tributary inputs.13”
    Quote in the paperSubstantial claim0 of 1 sources checked
    • cites [13]

      Couldn’t be matched to a paper in Crossref, so it can’t be checked.

  • Classified as probably not a substantial claim. May combine two claims.

    Study design and conductcitation

    Sites were sampled under approximate base-flow conditions (3 days after about 6 mm of precipitation) and near long-term median mean daily streamflow values for those days of the year at nearby streamgages.

    “Sites were sampled under approximate base-flow conditions (3 days after ∼6 mm of precipitation) 21 and near long-term median mean daily streamflow values for those days of the year at nearby streamgages.22”
    Quote in the paperSubstantial claim0 of 2 sources checked
    • cites [21]

      Couldn’t be matched to a paper in Crossref, so it can’t be checked.

    • cites [22] source
  • Classified as probably not a substantial claim. May combine two claims.

    Study design and conductcitation

    At each sampling location, discrete surface water samples were collected following standard U.S. Geological Survey sampling protocols and utilized a spatially integrated sampling approach (equal width intervals, depth integrated) across the stream channel.

    “At each sampling location, discrete surface water samples were collected following standard U.S. Geological Survey (USGS) sampling protocols and utilized a spatially integrated sampling approach (equal width intervals, depth integrated) across the stream channel.24”
    Quote in the paperSubstantial claim0 of 1 sources checked
    • cites [24]

      Couldn’t be matched to a paper in Crossref, so it can’t be checked.

  • Classified as probably not a substantial claim.

    Study design and conductnone given

    Samples were collected using a time-of-travel approach such that sampling occurred on the day and time when the same parcel of water was computed to reach each site.

    “Over a three-day period (November 16-18, 2021), samples were collected using a time-of-travel approach such that sampling occurred on the day/time when the same parcel of water was computed to reach each site.”
    Quote in the paperSubstantial claim
  • Classified as probably not a substantial claim. May combine two claims.

    Premisecitation

    Time-of-travel approaches allow for estimations of the rate of movement of a contaminant through a river reach, the rate of attenuation of the highest concentration, and the approximate length of time required for a contaminant to pass a point in the river.

    “Time-of-travel approaches allow for estimations of the rate of movement of a contaminant through a river reach, the rate of attenuation of the highest concentration, and the approximate length of time required for a contaminant to pass a point in the river.13”
    Quote in the paperSubstantial claim0 of 1 sources checked
    • cites [13]

      Couldn’t be matched to a paper in Crossref, so it can’t be checked.

  • Probably not a substantial claim: may not pass S3 (load-bearing).

    Study design and conductown data

    A replicate PFAS sample was collected for quality control at Site 5.

    “A replicate PFAS sample was collected for quality control at Site 5 (SW-16, USGS station no.014648955).”
    Quote in the paperNot a substantial claim
  • May combine two claims.

    Premisecitation

    The study catchment contains documented PFAS point sources (military bases with AFFF releases and STP outfalls) and diffuse sources (urban runoff and groundwater with documented PFAS contamination) and consequently PFAS surface and groundwater contamination.

    “The catchment contains documented PFAS point sources (military bases with AFFF releases and STP outfalls that discharge to streams) and diffuse sources (urban runoff and groundwater with documented PFAS contamination that discharge to streams) and consequently, PFAS surface and groundwater contamination.4,11,18”
    Quote in the paperSubstantial claim0 of 3 sources checked
    • cites [4] source
    • cites [11] source
    • cites [18] source
  • Probably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.

    Premisecitation

    Sources of PFAS to surface water include PFAS manufacturing, microchip manufacturing, metal-plating, textile industries, sewage treatment plants, combined sewer overflows, landfills, and aqueous film-forming foam releases.

    “Sources of PFAS to surface water include PFAS manufacturing, microchip manufacturing, metal-plating, textile industries, sewage treatment plants (STPs), combined sewer overflows, landfills, and aqueous film-forming foam (AFFF) releases, among others.”
    Quote in the paperNot a substantial claim0 of 3 sources checked
    • cites [4] source
    • cites [5] source
    • cites [6] source
  • Probably not a substantial claim: may not pass S3 (load-bearing).

    Interpretationreasoning

    Those percent increases may be larger or smaller depending on variable STP discharge.

    “Those percent increases may be larger or smaller depending on variable STP discharge.”
    Quote in the paperNot a substantial claim
  • Probably not a substantial claim: may not pass S3 (load-bearing).

    Study design and conductcitation

    For PFAS collection, additional steps were added to standard procedures to reduce sample contamination, focused on sampling equipment types, equipment cleaning, and the clean-hands/dirty-hands procedure.

    “For PFAS collection, additional steps were added to standard procedures to reduce sample contamination, and these additional steps focused on sampling equipment types, equipment cleaning, and details on the clean-hands/dirty-hands procedure.4”
    Quote in the paperNot a substantial claim0 of 1 sources checked
    • cites [4] source
  • Probably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.

    Interpretationcitation

    Pumping wells in the vicinity and complex groundwater/surface water interactions in this fractured-rock setting could be contributing to streamflow loss.

    “Pumping wells in the vicinity and complex groundwater/surface water interactions in this fractured-rock setting could be contributing to streamflow loss.11”
    Quote in the paperNot a substantial claim0 of 1 sources checked
    • cites [11] source
  • Probably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.

    Study design and conductcitation

    Equipment blanks and field blanks were not part of this synoptic study but were part of a larger Pennsylvania statewide study.

    “Equipment blanks and field blanks were not part of this synoptic study but were part of a larger Pennsylvania statewide study and are described by Breitmeyer et al. (2023).4”
    Quote in the paperNot a substantial claim0 of 1 sources checked
    • cites Breitmeyer et al. (2023) source
  • May combine two claims.

    Premisecitation

    Reports have quantified concentrations of PFCA and PFSA compounds in groundwater at and near the base, and when above background, PFSA compound concentrations, especially PFOS and PFHxS, routinely exceed PFCA (PFOA) concentrations.

    “Moreover, reports have also quantified concentrations of PFCA and PFSA compounds in groundwater at and near the base, and when above background, PFSA compound concentrations, especially PFOS and PFHxS, routinely exceed PFCA (PFOA) concentrations.36,37”
    Quote in the paperSubstantial claim0 of 2 sources checked
    • cites [36]

      Couldn’t be matched to a paper in Crossref, so it can’t be checked.

    • cites [37]

      Couldn’t be matched to a paper in Crossref, so it can’t be checked.

  • Probably not a substantial claim: may not pass S3 (load-bearing).

    Interpretationreasoning

    Daily fluctuations in effluent flows, treatment technologies, and general waste differences by plants could account for the differences in both PFAS and pharmaceutical loading from these plants.

    “Daily fluctuations in effluent flows, treatment technologies, and general waste differences by plants could account for the differences in both PFAS (Figure 2) and pharmaceutical (Figure S4) loading from these plants.”
    Quote in the paperNot a substantial claim
  • Probably not a substantial claim: may not pass S3 (load-bearing).

    Premisecitation

    Other studies have shown decreases in 6:2 FTS mass in sediment and water from chemical oxidation or biotransformation of 6:2 FTS into terminal PFAS under certain environmental conditions.

    “Other studies have shown decreases in 6:2 FTS mass in sediment and water from chemical oxidation or biotransformation of 6:2 FTS into terminal PFAS under certain environmental conditions (presence of ultraviolet light, hydrogen peroxide concentration, and dissolved oxygen concentration).32,41,42”
    Quote in the paperNot a substantial claim0 of 3 sources checked
    • cites [32] source
    • cites [41] source
    • cites [42] source
  • Classified as probably not a substantial claim. May combine two claims.

    Premisecitation

    Optical brighteners are fluorescent chemical agents used to whiten and brighten materials, and their removal during STP treatment varies by compound.

    “Optical brighteners are fluorescent chemical agents used to whiten and brighten materials, and their removal during STP treatment varies by compound.56,57”
    Quote in the paperSubstantial claim0 of 2 sources checked
    • cites [56] source
    • cites [57] source
  • May combine two claims.

    Premisecitation

    Permitted influent for LCSTP included two industrial dischargers: an industrial user in the electronics and manufacturing sector and an industrial user in the food production sector.

    “Permitted influent for LCSTP included two industrial dischargers: an industrial user in the electronics and manufacturing sector and an industrial user in the food production sector.”
    Quote in the paperNot a substantial claim0 of 1 sources checked
    • cites written communication, December 4, 2023

      Couldn’t be matched to a paper in Crossref, so it can’t be checked.

  • May combine two claims.

    Premisecitation

    Neither PCSTP nor LCSTP accepted any hauled waste.

    “Neither PCSTP nor LCSTP accepted any hauled waste.”
    Quote in the paperSubstantial claim0 of 1 sources checked
    • cites written communication, December 4, 2023

      Couldn’t be matched to a paper in Crossref, so it can’t be checked.

  • Probably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.

    Premisecitation

    Hamid et al. (2020) indicate that indirect photolysis of 6:2 FTS is a relevant transformation pathway with a 15-day half-life using simulated sunlight in the presence of landfill leachate, suggesting that photolysis is a likely transformation catalyst in sunlit aquatic environments.

    “Hamid et al. (2020) 43 indicate that indirect photolysis of 6:2 FTS is a relevant transformation pathway with a 15-day half-life using simulated sunlight in the presence of landfill leachate, suggesting that photolysis is a likely transformation catalyst in sunlit aquatic environments.”
    Quote in the paperNot a substantial claim0 of 2 sources checked
    • cites Hamid et al. (2020)

      Couldn’t be matched to a paper in Crossref, so it can’t be checked.

    • cites [43] source
  • Classified as probably not a substantial claim.

    Premisecitation

    Pharmaceutical compounds fexofenadine and metformin, combined with the elements Zn, Gd, and B, have been used to trace and/or characterize wastewater effluent source inputs.

    “The pharmaceutical compounds fexofenadine and metformin, combined with the elements Zn, Gd, and B, have been used to trace and/or characterize wastewater effluent source inputs.5,[52][53][54][55]”
    Quote in the paperSubstantial claim0 of 3 sources checked
    • cites [5] source
    • cites [52]

      Couldn’t be matched to a paper in Crossref, so it can’t be checked.

    • cites [53]

      Couldn’t be matched to a paper in Crossref, so it can’t be checked.

  • Probably not a substantial claim: may not pass S3 (load-bearing).

    Interpretationreasoning

    Four additional potential sources located near the tributary that enters between sites 9 and 10 could be contributing PFAS loads in addition to military base drainage.

    “There are four additional potential sources located near the tributary that enters between sites 9 and 10 (Figure S5) that could be contributing PFAS loads in addition to military base drainage (Figure 2).”
    Quote in the paperNot a substantial claim
  • May combine two claims.

    Interpretationreasoning

    For PCSTP, the only permitted waste discharged to streams was from domestic sources, and for LCSTP, the only permitted waste discharged was from domestic sources and the two noted industrial sources.

    “Thus, for PCSTP, the only permitted waste that was discharged to streams was from domestic sources, and for LCSTP, the only permitted waste that was discharged was from domestic sources and the two noted industrial sources.”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Interpretationreasoning

    Surface-water PFAS sources from NASJRB Willow Grove and BANG could be from direct runoff, outfall discharge, and/or groundwater discharge.

    “Surface-water PFAS sources from NASJRB Willow Grove and BANG could be from direct runoff, outfall discharge, and/or groundwater discharge.”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Interpretationreasoning

    Additional sources, as well as potential atmospheric deposition, may help explain the total PFAS load increase between sites 12 and 13 and suggest that many other potential sources in the catchment could warrant further investigation.

    “These additional sources, as well as potential atmospheric deposition, may help explain the total PFAS load increase between sites 12 (118 μg/s) and 13 (223 μg/s) and suggest that while this study focused on a few major inputs, there are many other potential sources in the catchment that could warrant further investigation.”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Interpretationown data

    A PCA model used as an exploratory tool discriminates source inputs within the study catchment and provides a second line of evidence corroborating the load analysis.

    “A PCA model was used as an exploratory tool to discriminate source inputs within the study catchment and provides a second line of evidence corroborating the load analysis (Figure 4; Table S5).”
    Quote in the paperSubstantial claim
  • Probably not a substantial claim: may not pass S3 (load-bearing).

    Premisecitation

    n-Pentanal is a chemical used in the food additives, packaging, printing, and plastic industries.

    “The compound n-pentanal is a chemical used in the food additives, packaging, printing, and plastic industries [60][61][62]”
    Quote in the paperNot a substantial claim0 of 1 sources checked
    • cites [60][61][62]

      Couldn’t be matched to a paper in Crossref, so it can’t be checked.

  • May combine two claims.

    Interpretationcitation

    HMTA likely reflected use in either industrial applications, medicine, or AFFF formulations.

    “which likely reflected use in either industrial applications, medicine, or AFFF formulations.65”
    Quote in the paperNot a substantial claim0 of 1 sources checked
    • cites [65]

      Couldn’t be matched to a paper in Crossref, so it can’t be checked.

  • May combine two claims.

    Interpretationown data

    Site 8 plotted in quadrant 1, reflecting a more background-like chemical signature.

    “Site 8, which represented the Little Neshaminy drainage upstream from Park Creek, plotted in quadrant 1, reflecting a more”
    Quote in the paperNot a substantial claim
  • May combine two claims.

    Interpretationreasoning

    Site 12 is downstream of LCSTP, and thus it is expected that this site would plot in Quadrant 4 with chemical variables indicative of municipal wastewater effluent.

    “Site 12 is downstream of LCSTP, and thus it is expected that this site would plot in Quadrant 4 with chemical variables that are indicative of municipal wastewater effluent.[52][53][54][55]58,67,68”
    Quote in the paperNot a substantial claim0 of 1 sources checked
    • cites [52][53][54][55]58,67,68

      Couldn’t be matched to a paper in Crossref, so it can’t be checked.

  • May combine two claims.

    Interpretationreasoning

    Although no source inputs were documented between sites 6 and 7, there was a shift between these two sites that suggested potential influence from municipal wastewater.

    “Although no source inputs were documented between sites 6 and 7, there was a shift between these two sites that suggested potential influence from municipal wastewater”
    Quote in the paperNot a substantial claim
  • Classified as probably not a substantial claim.

    Premisecitation

    The ratio of fluorescence in the Flr_T region (more labile DOM) to the Flr_C region (more humic DOM) has also been widely used to indicate the presence of wastewater in surface waters.

    “The ratio of fluorescence in the “Flr_T” region (more labile DOM) to the “Flr_C” region (more humic DOM) has also been widely used to indicate the presence of wastewater in surface waters.58,59”
    Quote in the paperSubstantial claim0 of 2 sources checked
    • cites [58]

      Couldn’t be matched to a paper in Crossref, so it can’t be checked.

    • cites [59] source
  • May combine two claims.

    Interpretationreasoning

    The shift from site 5 to site 6 resembled the shift between sites 2 and 3, indicative of industrial and potential AFFF sources in the tributaries draining the military base, in particular BANG.

    “The shift from site 5 to site 6 resembled the shift between sites 2 and 3, which again is indicative of industrial and potential AFFF sources in the tributaries draining the military base, in particular BANG (Figure 1).”
    Quote in the paperSubstantial claim
  • Classified as probably not a substantial claim.

    Study design and conductnone given

    Sampling locations were chosen to capture loads directly upstream and downstream of source inputs.

    “sampling locations were chosen to capture loads directly upstream and downstream of these source inputs.”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Interpretationown data

    From sites 10 to 11 there was minimal change suggesting that either new source inputs were limited or were similar in chemical signature.

    “From sites 10 to 11 there was minimal change suggesting that either new source inputs were limited or were similar in chemical signature.”
    Quote in the paperNot a substantial claim
  • May combine two claims.

    Interpretationreasoning

    In larger catchments with multiple sources, identifying specific source loadings can be more challenging, and inputs such as current and legacy groundwater flux could be missed.

    “In larger catchments with multiple sources, identifying specific source loadings can be more challenging, and inputs such as current and legacy groundwater flux could be missed.”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Interpretationown data

    This study quantified PFAS loadings from known sources and discriminated sampling sites using time-of-travel sampling, flow-integrated sampling, streamflow measurements, and varied chemical data sets.

    “Utilizing a time-of-travel sampling approach, flow-integrated sampling, and streamflow measurements, this study quantified PFAS loadings from known sources and further discriminated sampling sites (i.e., source inputs) using a combination of varied chemical data sets.”
    Quote in the paperSubstantial claim
69 of 69
  • The authors state this as an assumption.

    PFAS concentration from the sewage treatment plant is constant for the diurnal variation estimate.

    “assuming constant PFAS concentration from the sewage treatment plant (Table S6)”
  • The authors state this as an assumption.

    Transport from site 12 to site 13 is conservative and there is no loss to groundwater/surface water interactions.

    “assuming conservative transport and no loss to groundwater/surface water interactions”
  • The authors state this as an assumption.

    STP effluent is a constant input for the percent increases in loads and streamflow between sites 4-5 and 12-13.

    “STP effluent (assumed as a constant input)”
3 of 3

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

Each contradiction between two passages listed here was confirmed by an independent check.

  • Site 6 has two different streamgage identifiers

    Minor

    The streamflow discussion and Figure 1 give different station numbers for the gage at site 6.

  • Site 13 has two different streamgage identifiers

    Minor

    The methods and Figure 1 assign different USGS streamgage numbers to site 13.

  • Abstract omits the smallest reported military-base PFSA increase

    Minor

    The abstract gives the range of PFSA load increases as 8 to 11 μg/s, but the results report a 6.8 μg/s increase for one of the three military-base site groupings.

  • Figure 4 points to a different table for PCA variables

    Minor

    The statistical methods say Table S5 describes the PCA variables, whereas the Figure 4 caption directs readers to Table S3 for their descriptions.

  • Gage downstream of site 12 has two identifiers

    Minor

    The streamflow discussion identifies the gage downstream of site 12 as 01464894, while Figure 1 identifies it as 01464984.

5 of 5

Cites

Flagged first, then by citations

Research works printed but not linked: 3

  1. Posit team, 2023, RStudio: Integrated development environment for R
  2. U.S. Navy Former Naval Air Warfare Center (NAWC) Warminster technical review committee (TRC) Meeting August 3, 2023 presentation
  3. Hagedorn C., 2005, Fluorometric detection of optical brighteners as an indicator of human sources of water pollution. Part I: Description and detection of optical brighteners

Cited by

Sorted by citations

Authors
Woodward, E. E., Senior, L. A., Fleck, J. A., Barber, L. B., Hansen, A. M., & Duris, J. W.
Affiliations
  • Pennsylvania Water Science Center (US)
  • California Water Science Center (US)
  • United States Geological Survey (US)
Corresponding author
Woodward, Emily E.
Venue
ACS ES&T Water
Published
2024-09-16
Volume
4
Issue
10
Pages
4356-4367
ISSN
2690-0637 (ISSN-L)
OpenAlex
W4402818450
Cited by
14
References
49
Citations by year
2026: 8 · 2025: 5 · 2024: 1
FWCI
1.84
Type
journal article
Language
en
Open access
Locations
ACS ES&T Water (publishedVersion, cc-by)
Funders
  • U.S. Geological Survey
  • Pennsylvania Department of Environmental Protection
Topics
  • Physical Sciences › Environmental Science › Environmental Chemistry › Per- and polyfluoroalkyl substances research
  • Physical Sciences › Environmental Science › Environmental Engineering › Urban Stormwater Management Solutions
  • Physical Sciences › Environmental Science › Pollution › Pharmaceutical and Antibiotic Environmental Impacts
Keywords
per- and polyfluoroalkyl substances, source attribution, perfluoroalkyl sulfonates, perfluoroalkyl carboxylates, sewage treatment plant discharge, urban watersheds, groundwater discharge, water resources management

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Claims read by deepseek-v4.1-flash under definition version 3 (extract-v3) on 2026-10-07.

Classified by jev-1.13-20260917 (gold-guideline-v0.2) on 2026-10-07.

Cited sources are checked by gpt-6-sol.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review