The DOI matches its Crossref record.
The Design and Fabrication of Three-Chamber Microscale Cell Culture Analog Devices with Integrated Dissolved Oxygen Sensors
Abstract
Whole animal testing is an essential part in evaluating the toxicological and pharmacological profiles of chemicals and pharmaceuticals, but these experiments are expensive and cumbersome. A cell culture analog (CCA) system, when used in conjunction with a physiologically based pharmacokinetic (PBPK) model, provides an in vitro supplement to animal studies and the possibility of a human surrogate for predicting human response in clinical trials. A PBPK model mathematically simulates animal metabolism by modeling the absorption, distribution, metabolism, and elimination kinetics of a chemical in interconnected tissue compartments. A CCA uses mammalian cells cultured in interconnected chambers to physically represent the corresponding PBPK. These compartments are connected by recirculating tissue culture medium that acts as a blood surrogate. The purpose of this article is to describe the design and basic operation of the microscale manifestation of such a system. Microscale CCAs offer the potential for inexpensive, relatively high throughput evaluation of chemicals while minimizing demand for reagents and cells. Using microfabrication technology, a three-chamber ("lung"-"liver"-"other") microscale cell culture analog (microCCA) device was fabricated on a 1 in. (2.54 cm) square silicon chip. With a design flow rate of 1.76 microL/min, this microCCA device achieves approximate physiological liquid-to-cell ratio and hydrodynamic shear stress while replicating the liquid residence time parameters in the PBPK model. A dissolved oxygen sensor based on collision quenching of a fluorescent ruthenium complex by oxygen molecules was integrated into the system, demonstrating the potential to integrate real-time sensors into such devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Reconstituting organ-level lung functions on a chip
Huh, D., Matthews, B. D., Mammoto, A., Montoya-Zavala, M., Hsin, H. Y., & Ingber, D. E. (2010) · Science · doi:10.1126/science.1188302 · Cited by 4,250
Bhatia, S. N., & Ingber, D. E. (2014) · Nature Biotechnology · doi:10.1038/nbt.2989 · Cited by 3,305
From 3D cell culture to organs-on-chips
Huh, D., Hamilton, G. A., & Ingber, D. E. (2011) · Trends in Cell Biology · doi:10.1016/j.tcb.2011.09.005 · Cited by 1,834
A guide to the organ-on-a-chip
Leung, C. M., de Haan, P., Ronaldson-Bouchard, K., Kim, G.-A., Ko, J., Rho, H. S., Chen, Z., Habibovic, P., Jeon, N. L., Takayama, S., et al. (2022) · Nature Reviews Methods Primers · doi:10.1038/s43586-022-00118-6 · Cited by 1,116
Self-citationAdvances in organ-on-a-chip engineering
Zhang, B., Korolj, A., Lai, B. F. L., & Radisic, M. (2018) · Nature Reviews Materials · doi:10.1038/s41578-018-0034-7 · Cited by 1,017
Organs-on-chips: into the next decade
Low, L. A., Mummery, C., Berridge, B. R., Austin, C. P., & Tagle, D. A. (2021) · Nature Reviews Drug Discovery · doi:10.1038/s41573-020-0079-3 · Cited by 1,029
Perfused multiwell plate for 3D liver tissue engineering
Domansky, K., Inman, W., Serdy, J., Dash, A., Lim, M. H. M., & Griffith, L. G. (2010) · Lab Chip · doi:10.1039/b913221j · Cited by 444
Organ-on-a-chip devices advance to market
Zhang, B., & Radisic, M. (2017) · Lab on a Chip · doi:10.1039/c6lc01554a · Cited by 437
Organ/body-on-a-chip based on microfluidic technology for drug discovery
Kimura, H., Sakai, Y., & Fujii, T. (2018) · Drug Metabolism and Pharmacokinetics · doi:10.1016/j.dmpk.2017.11.003 · Cited by 435
Organ-on-a-chip platforms for studying drug delivery systems
Bhise, N. S., Ribas, J., Manoharan, V., Zhang, Y. S., Polini, A., Massa, S., Dokmeci, M. R., & Khademhosseini, A. (2014) · Journal of Controlled Release · doi:10.1016/j.jconrel.2014.05.004 · Cited by 381
Lee, H., & Cho, D.-W. (2016) · Lab on a Chip · doi:10.1039/c6lc00450d · Cited by 363
Differentiation-on-a-chip: A microfluidic platform for long-term cell culture studies
Tourovskaia, A., Figueroa-Masot, X., & Folch, A. (2005) · Lab on a Chip · doi:10.1039/b405719h · Cited by 363
Industrial lab-on-a-chip: Design, applications and scale-up for drug discovery and delivery
Vladisavljević, G. T., Khalid, N., Neves, M. A., Kuroiwa, T., Nakajima, M., Uemura, K., Ichikawa, S., & Kobayashi, I. (2013) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2013.07.017 · Cited by 313
Marx, U. (2016) · ALTEX · doi:10.14573/altex.1603161 · Cited by 295
Recent advances in microfluidic technologies for cell-to-cell interaction studies
Rothbauer, M., Zirath, H., & Ertl, P. (2018) · Lab on a Chip · doi:10.1039/c7lc00815e · Cited by 277
Recent Advances in Body-on-a-Chip Systems
Sung, J. H., Wang, Y. I., Narasimhan Sriram, N., Jackson, M., Long, C., Hickman, J. J., & Shuler, M. L. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.8b05293 · Cited by 268
Self-citationOrgans-on-a-chip models for biological research
Vunjak-Novakovic, G., Ronaldson-Bouchard, K., & Radisic, M. (2021) · Cell · doi:10.1016/j.cell.2021.08.005 · Cited by 248
“‘‘Organs-on-a-chip’’ (OOC) evolved in the late 1990s, with the idea of ‘‘human-body-on-a-chip’’ for studies of human physiology being introduced shortly thereafter by the Shuler lab (Sin et al., 2004).”
BackgroundTsamandouras, N., Chen, W. L. K., Edington, C. D., Stokes, C. L., Griffith, L. G., & Cirit, M. (2017) · The AAPS Journal · doi:10.1208/s12248-017-0122-4 · Cited by 222
Long‐term maintenance of a microfluidic 3D human liver sinusoid
Prodanov, L., Jindal, R., Bale, S. S., Hegde, M., McCarty, W. J., Golberg, I., Bhushan, A., Yarmush, M. L., & Usta, O. B. (2016) · Biotechnology and Bioengineering · doi:10.1002/bit.25700 · Cited by 214
Satoh, T., Sugiura, S., Shin, K., Onuki-Nagasaki, R., Ishida, S., Kikuchi, K., Kakiki, M., & Kanamori, T. (2018) · Lab on a Chip · doi:10.1039/c7lc00952f · Cited by 181
Prantil-Baun, R., Novak, R., Das, D., Somayaji, M. R., Przekwas, A., & Ingber, D. E. (2018) · Annual Review of Pharmacology and Toxicology · doi:10.1146/annurev-pharmtox-010716-104748 · Cited by 176
Integrated gut/liver microphysiological systems elucidates inflammatory inter‐tissue crosstalk
Chen, W. L. K., Edington, C., Suter, E., Yu, J., Velazquez, J. J., Velazquez, J. G., Shockley, M., Large, E. M., Venkataramanan, R., Hughes, D. J., et al. (2017) · Biotechnology and Bioengineering · doi:10.1002/bit.26370 · Cited by 172
On being the right size: scaling effects in designing a human-on-a-chip
Moraes, C., Labuz, J. M., Leung, B. M., Inoue, M., Chun, T.-H., & Takayama, S. (2013) · Integrative Biology · doi:10.1039/c3ib40040a · Cited by 134
3D spherical microtissues and microfluidic technology for multi-tissue experiments and analysis
Kim, J.-Y., Fluri, D. A., Marchan, R., Boonen, K., Mohanty, S., Singh, P., Hammad, S., Landuyt, B., Hengstler, J. G., Kelm, J. M., et al. (2015) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2015.01.003 · Cited by 126
Microfluidic devices for in vitro studies on liver drug metabolism and toxicity
van Midwoud, P. M., Verpoorte, E., & Groothuis, G. M. M. (2011) · Integrative Biology · doi:10.1039/c0ib00119h · Cited by 115
Organs-on-a-chip: a union of tissue engineering and microfabrication
Zhao, Y., Wang, E. Y., Lai, F. B. L., Cheung, K., & Radisic, M. (2023) · Trends in Biotechnology · doi:10.1016/j.tibtech.2022.12.018 · Cited by 93
Lee, J. B., & Sung, J. H. (2013) · Biotechnology Journal · doi:10.1002/biot.201300086 · Cited by 92
Organ-Tumor-on-a-Chip for Chemosensitivity Assay: A Critical Review
Kashaninejad, N., Nikmaneshi, M., Moghadas, H., Kiyoumarsi Oskouei, A., Rismanian, M., Barisam, M., Saidi, M., & Firoozabadi, B. (2016) · Micromachines · doi:10.3390/mi7080130 · Cited by 79
Sung, J. H., Wang, Y., & Shuler, M. L. (2019) · APL Bioengineering · doi:10.1063/1.5097675 · Cited by 66
Self-citationSelf-contained, low-cost Body-on-a-Chip systems for drug development
Wang, Y. I., Oleaga, C., Long, C. J., Esch, M. B., McAleer, C. W., Miller, P. G., Hickman, J. J., & Shuler, M. L. (2017) · Experimental Biology and Medicine · doi:10.1177/1535370217694101 · Cited by 59
Self-citationRivera, K. R., Yokus, M. A., Erb, P. D., Pozdin, V. A., & Daniele, M. (2019) · The Analyst · doi:10.1039/c8an02201a · Cited by 57
Critical Considerations for the Design of Multi-Organ Microphysiological Systems (MPS)
Malik, M., Yang, Y., Fathi, P., Mahler, G. J., & Esch, M. B. (2021) · Frontiers in Cell and Developmental Biology · doi:10.3389/fcell.2021.721338 · Cited by 43
In vitro micro-physiological models for translational immunology
Ramadan, Q., & Gijs, M. A. M. (2015) · Lab on a Chip · doi:10.1039/c4lc01271b · Cited by 41
Alternative strategies in cardiac preclinical research and new clinical trial formats
Kreutzer, F. P., Meinecke, A., Schmidt, K., Fiedler, J., & Thum, T. (2022) · Cardiovascular Research · doi:10.1093/cvr/cvab075 · Cited by 36
Metadata
- Authors
- Sin, A., Chin, K. C., Jamil, M. F., Kostov, Y., Rao, G., & Shuler, M. L.
- Venue
- Biotechnology Progress
- Publisher
- Wiley
- Published
- 2008-09-05
- Volume
- 20
- Issue
- 1
- Pages
- 338-345
- ISSN
- 1520-6033 (ISSN-L)
- 8756-7938
- OpenAlex
- W2099191040
- Cited by
- 368
- References
- 0
- FWCI
- 8.83
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.