An epidermal patch for the simultaneous monitoring of haemodynamic and metabolic biomarkers
Open accessPublished version of a preprint
The DOI matches its Crossref record; 58 of the 58 references it cites were found in a registry or an index.
Abstract
Monitoring the effects of daily activities on the physiological responses of the body calls for wearable devices that can simultaneously track metabolic and haemodynamic parameters. Here we describe a non-invasive skin-worn device for the simultaneous monitoring of blood pressure and heart rate via ultrasonic transducers and of multiple biomarkers via electrochemical sensors. We optimized the integrated device so that it provides mechanical resiliency and flexibility while conforming to curved skin surfaces, and to ensure reliable sensing of glucose in interstitial fluid and of lactate, caffeine and alcohol in sweat, without crosstalk between the individual sensors. In human volunteers, the device captured physiological effects of food intake and exercise, in particular the production of glucose after food digestion, the consumption of glucose via glycolysis, and increases in blood pressure and heart rate compensating for oxygen depletion and lactate generation. Continuous and simultaneous acoustic and electrochemical sensing via integrated wearable devices should enrich the understanding of the body's response to daily activities, and could facilitate the early prediction of abnormal physiological changes.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Sweat detection can respond in real-time to changes in the volume and rate of sweat loss,[241,242] as well as the concentration of various ions and metabolites in the body.[45,243–245]”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [245]
Citations
Cites
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087
Yang, J., Zheng, Y., Gou, X., Pu, K., Chen, Z., Guo, Q., Ji, R., Wang, H., Wang, Y., & Zhou, Y. (2020) · International Journal of Infectious Diseases · doi:10.1016/j.ijid.2020.03.017 · Cited by 4,206
Wearable biosensors for healthcare monitoring
Kim, J., Campbell, A. S., de Ávila, B. E.-F., & Wang, J. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0045-y · Cited by 3,373
Self-citationMonitoring of Vital Signs with Flexible and Wearable Medical Devices
Khan, Y., Ostfeld, A. E., Lochner, C. M., Pierre, A., & Arias, A. C. (2016) · Advanced Materials · doi:10.1002/adma.201504366 · Cited by 1,408
Lee, H., Song, C., Hong, Y. S., Kim, M., Cho, H. R., Kang, T., Shin, K., Choi, S. H., Hyeon, T., & Kim, D.-H. (2017) · Science Advances · doi:10.1126/sciadv.1601314 · Cited by 1,118
Dagdeviren, C., Su, Y., Joe, P., Yona, R., Liu, Y., Kim, Y.-S., Huang, Y., Damadoran, A. R., Xia, J., Martin, L. W., et al. (2014) · Nature Communications · doi:10.1038/ncomms5496 · Cited by 987
Monitoring of the central blood pressure waveform via a conformal ultrasonic device
Wang, C., Li, X., Hu, H., Zhang, L., Huang, Z., Lin, M., Zhang, Z., Yin, Z., Huang, B., Gong, H., et al. (2018) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0287-x · Cited by 895
Self-citationImani, S., Bandodkar, A. J., Mohan, A. M. V., Kumar, R., Yu, S., Wang, J., & Mercier, P. P. (2016) · Nature Communications · doi:10.1038/ncomms11650 · Cited by 861
Self-citationEmaminejad, S., Gao, W., Wu, E., Davies, Z. A., Yin Yin Nyein, H., Challa, S., Ryan, S. P., Fahad, H. M., Chen, K., Shahpar, Z., et al. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1701740114 · Cited by 839
Cardiovascular Effects and Benefits of Exercise
Nystoriak, M. A., & Bhatnagar, A. (2018) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2018.00135 · Cited by 833
Binodal, wireless epidermal electronic systems with in-sensor analytics for neonatal intensive care
Chung, H. U., Kim, B. H., Lee, J. Y., Lee, J., Xie, Z., Ibler, E. M., Lee, K., Banks, A., Jeong, J. Y., Kim, J., et al. (2019) · Science · doi:10.1126/science.aau0780 · Cited by 807
Self-citationSensor and biosensor preparation, optimisation and applications of Prussian Blue modified electrodes
Ricci, F., & Palleschi, G. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.12.001 · Cited by 781
Enzyme‐Based Glucose Sensor: From Invasive to Wearable Device
Lee, H., Hong, Y. J., Baik, S., Hyeon, T., & Kim, D. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201701150 · Cited by 778
Tattoo-Based Noninvasive Glucose Monitoring: A Proof-of-Concept Study
Bandodkar, A. J., Jia, W., Yardımcı, C., Wang, X., Ramirez, J., & Wang, J. (2015) · Analytical Chemistry · doi:10.1021/ac504300n · Cited by 700
Self-citationMaterials and Structures toward Soft Electronics
Wang, C., Wang, C., Huang, Z., & Xu, S. (2018) · Advanced Materials · doi:10.1002/adma.201801368 · Cited by 662
Self-citationDiabetes mellitus and hypertension.
Epstein, M., & Sowers, J. R. (1992) · Hypertension · doi:10.1161/01.hyp.19.5.403 · Cited by 600
Wearable non-invasive epidermal glucose sensors: A review
Kim, J., Campbell, A. S., & Wang, J. (2018) · Talanta · doi:10.1016/j.talanta.2017.08.077 · Cited by 586
Self-citationDiabetes and Hypertension: Is There a Common Metabolic Pathway?
Cheung, B. M. Y., & Li, C. (2012) · Current Atherosclerosis Reports · doi:10.1007/s11883-012-0227-2 · Cited by 576
Roerecke, M., Kaczorowski, J., Tobe, S. W., Gmel, G., Hasan, O. S. M., & Rehm, J. (2017) · The Lancet Public Health · doi:10.1016/s2468-2667(17)30003-8 · Cited by 552
Mechanisms and Clinical Implications of Post-exercise Hypotension in Humans
Halliwill, J. R. (2001) · Exercise and Sport Sciences Reviews · doi:10.1097/00003677-200104000-00005 · Cited by 534
Simultaneous Monitoring of Sweat and Interstitial Fluid Using a Single Wearable Biosensor Platform
Kim, J., Sempionatto, J. R., Imani, S., Hartel, M. C., Barfidokht, A., Tang, G., Campbell, A. S., Mercier, P. P., & Wang, J. (2018) · Advanced Science · doi:10.1002/advs.201800880 · Cited by 526
Self-citationPotential causes, mechanisms, and implications of post exercise hypotension
MacDonald, J. R. (2002) · Journal of Human Hypertension · doi:10.1038/sj.jhh.1001377 · Cited by 502
Flexible Piezoresistive Sensor Patch Enabling Ultralow Power Cuffless Blood Pressure Measurement
Luo, N., Dai, W., Li, C., Zhou, Z., Lu, L., Poon, C. C. Y., Chen, S., Zhang, Y., & Zhao, N. (2016) · Advanced Functional Materials · doi:10.1002/adfm.201504560 · Cited by 467
Wireless sensor network based wearable smart shirt for ubiquitous health and activity monitoring
Lee, Y.-D., & Chung, W.-Y. (2009) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2009.04.040 · Cited by 382
Coffee, caffeine and blood pressure: a critical review
Nurminen, M.-L., Niittynen, L., Korpela, R., & Vapaatalo, H. (1999) · European Journal of Clinical Nutrition · doi:10.1038/sj.ejcn.1600899 · Cited by 351
Flexible Electrochemical Bioelectronics: The Rise of In Situ Bioanalysis
Yu, Y., Nyein, H. Y. Y., Gao, W., & Javey, A. (2020) · Advanced Materials · doi:10.1002/adma.201902083 · Cited by 349
Epidermal Biofuel Cells: Energy Harvesting from Human Perspiration
Jia, W., Valdés‐Ramírez, G., Bandodkar, A. J., Windmiller, J. R., & Wang, J. (2013) · Angewandte Chemie International Edition · doi:10.1002/anie.201302922 · Cited by 324
Self-citationChen, L., Davey Smith, G., Harbord, R. M., & Lewis, S. J. (2008) · PLoS Medicine · doi:10.1371/journal.pmed.0050052 · Cited by 314
Monte-Moreno, E. (2011) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2011.05.001 · Cited by 311
Methylxanthine Drug Monitoring with Wearable Sweat Sensors
Tai, L., Gao, W., Chao, M., Bariya, M., Ngo, Q. P., Shahpar, Z., Nyein, H. Y. Y., Park, H., Sun, J., Jung, Y., et al. (2018) · Advanced Materials · doi:10.1002/adma.201707442 · Cited by 310
A Fully Integrated and Self-Powered Smartwatch for Continuous Sweat Glucose Monitoring
Zhao, J., Lin, Y., Wu, J., Nyein, H. Y. Y., Bariya, M., Tai, L.-C., Chao, M., Ji, W., Zhang, G., Fan, Z., et al. (2019) · ACS Sensors · doi:10.1021/acssensors.9b00891 · Cited by 280
Graphene-clad textile electrodes for electrocardiogram monitoring
Yapici, M. K., Alkhidir, T., Samad, Y. A., & Liao, K. (2015) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2015.07.111 · Cited by 239
Hong, Y. J., Lee, H., Kim, J., Lee, M., Choi, H. J., Hyeon, T., & Kim, D. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201805754 · Cited by 229
Highly flexible, wearable, and disposable cardiac biosensors for remote and ambulatory monitoring
Lee, S. P., Ha, G., Wright, D. E., Ma, Y., Sen-Gupta, E., Haubrich, N. R., Branche, P. C., Li, W., Huppert, G. L., Johnson, M., et al. (2018) · npj Digital Medicine · doi:10.1038/s41746-017-0009-x · Cited by 225
Blood viscosity and blood pressure: role of temperature and hyperglycemia
Çinar, Y. (2001) · American Journal of Hypertension · doi:10.1016/s0895-7061(00)01260-7 · Cited by 190
Relationship between Lactate Concentrations in Active Muscle Sweat and Whole Blood
Sakharov, D. A., Shkurnikov, M. Y., Vagin, M. Y., Yashina, E. I., Karyakin, A. A., & Tonevitsky, A. (2010) · Bulletin of Experimental Biology and Medicine · doi:10.1007/s10517-010-1075-0 · Cited by 177
Hauke, A., Simmers, P., Ojha, Y. R., Cameron, B. D., Ballweg, R., Zhang, T., Twine, N., Brothers, M., Gomez, E., & Heikenfeld, J. (2018) · Lab on a Chip · doi:10.1039/c8lc01082j · Cited by 156
Cardiorespiratory Fitness, Exercise, and Blood Pressure
Kokkinos, P. F. (2014) · Hypertension · doi:10.1161/hypertensionaha.114.03616 · Cited by 139
Filipovsky, J., Ducimetiere, P., Eschwege, E., Richard, J. L., Rosselin, G., & Claude, J. R. (1996) · Journal of Hypertension · doi:10.1097/00004872-199602000-00012 · Cited by 137
Treatment of Obesity Hypertension and Diabetes Syndrome
Zanella, M. T., Kohlmann, O., & Ribeiro, A. B. (2001) · Hypertension · doi:10.1161/01.hyp.38.3.705 · Cited by 135
Alcohol Consumption, Blood Pressure, and the Risk of Stroke
Hillbom, M., Saloheimo, P., & Juvela, S. (2011) · Current Hypertension Reports · doi:10.1007/s11906-011-0194-y · Cited by 133
Ohira, T., Tanigawa, T., Tabata, M., Imano, H., Kitamura, A., Kiyama, M., Sato, S., Okamura, T., Cui, R., Koike, K. A., et al. (2009) · Hypertension · doi:10.1161/hypertensionaha.108.114835 · Cited by 115
DEEDWANIA, P. C. (2010) · Journal of Clinical Hypertension · doi:10.1111/j.1751-7176.2010.00386.x · Cited by 107
Effects of exercise, diet and their combination on blood pressure
Fagard, R. H. (2005) · Journal of Human Hypertension · doi:10.1038/sj.jhh.1001956 · Cited by 101
Acute effects of physical exercise in type 2 diabetes: A review
Asano, R. Y. (2014) · World Journal of Diabetes · doi:10.4239/wjd.v5.i5.659 · Cited by 99
Timing of Blood Pressure Measurement Related to Caffeine Consumption
Mort, J. R., & Kruse, H. R. (2008) · Annals of Pharmacotherapy · doi:10.1345/aph.1k337 · Cited by 98
Chemical Sensing at the Robot Fingertips: Toward Automated Taste Discrimination in Food Samples
Ciui, B., Martin, A., Mishra, R. K., Nakagawa, T., Dawkins, T. J., Lyu, M., Cristea, C., Sandulescu, R., & Wang, J. (2018) · ACS Sensors · doi:10.1021/acssensors.8b00778 · Cited by 98
Self-citationRosa, B. M. G., Anastasova, S., & Yang, G. (2019) · Sensors · doi:10.3390/s19071616 · Cited by 68
High blood pressure due to alcohol. A rapidly reversible effect.
Maheswaran, R., Gill, J. S., Davies, P., & Beevers, D. G. (1991) · Hypertension · doi:10.1161/01.hyp.17.6.787 · Cited by 64
Sarker, R., Valkhoff, V. E., Zachos, N. C., Lin, R., Cha, B., Chen, T.-E., Guggino, S., Zizak, M., de Jonge, H., Hogema, B., et al. (2011) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.00119.2010 · Cited by 52
Gómez, H., & Kellum, J. A. (2015) · JAMA · doi:10.1001/jama.2014.13811 · Cited by 44
Influence of acute alcohol ingestion on sympathetic neural responses to orthostatic stress in humans
Carter, J. R., Stream, S. F., Durocher, J. J., & Larson, R. A. (2011) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.00674.2010 · Cited by 44
Sensors in neonatal monitoring: Current practice and future trends
Murković, I., Steinberg, M. D., & Murković, B. (2003) · Technology and Health Care · doi:10.3233/thc-2003-11602 · Cited by 42
A Combined Approach of Field Data and Earth Observation for Coastal Risk Assessment
Bruno, M. F., Molfetta, M. G., Pratola, L., Mossa, M., Nutricato, R., Morea, A., Nitti, D. O., & Chiaradia, M. T. (2019) · Sensors · doi:10.3390/s19061399 · Cited by 40
Effect of differences in post-exercise lactate accumulation in athletes’ haemodynamics
Crisafulli, A., Tocco, F., Pittau, G., Lorrai, L., Porru, C., Salis, E., Pagliaro, P., Melis, F., & Concu, A. (2006) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/h06-017 · Cited by 38
Severe hypotension and hypothermia caused by acute ethanol toxicity
Wilson, E. M., & Waring, W. S. (2007) · Emergency Medicine Journal · doi:10.1136/emj.2006.041590 · Cited by 24
Ho, K. K. Y., Peng, Y.-W., Ye, M., Tchouta, L., Schneider, B., Hayes, M., Toomasian, J. M., Cornell, M. S., Rojas-Peña, Á., Charpie, J. R., et al. (2020) · Chemosensors · doi:10.3390/chemosensors8030056 · Cited by 11
Alcohol-Induced Coma, Hypothermia and Hypotension
Klarić, D., & Klarić, V. (2015) · Journal of Membrane Science & Technology · doi:10.4172/2155-9589.1000137 · Cited by 3
Cited by
Technology Roadmap for Flexible Sensors
Luo, Y., Abidian, M. R., Ahn, J.-H., Akinwande, D., Andrews, A. M., Antonietti, M., Bao, Z., Berggren, M., Berkey, C. A., Bettinger, C. J., et al. (2023) · ACS Nano · doi:10.1021/acsnano.2c12606 · Cited by 1,383
A wearable electrochemical biosensor for the monitoring of metabolites and nutrients
Wang, M., Yang, Y., Min, J., Song, Y., Tu, J., Mukasa, D., Ye, C., Xu, C., Heflin, N., McCune, J. S., et al. (2022) · Nature Biomedical Engineering · doi:10.1038/s41551-022-00916-z · Cited by 896
Wearable and flexible electrochemical sensors for sweat analysis: a review
Gao, F., Liu, C., Zhang, L., Liu, T., Wang, Z., Song, Z., Cai, H., Fang, Z., Chen, J., Wang, J., et al. (2023) · Microsystems & Nanoengineering · doi:10.1038/s41378-022-00443-6 · Cited by 764
Self-citationSkin-Interfaced Wearable Sweat Sensors for Precision Medicine
Min, J., Tu, J., Xu, C., Lukas, H., Shin, S., Yang, Y., Solomon, S. A., Mukasa, D., & Gao, W. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.2c00823 · Cited by 712
Electronic Textiles for Wearable Point-of-Care Systems
Chen, G., Xiao, X., Zhao, X., Tat, T., Bick, M., & Chen, J. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00502 · Cited by 688
Metadata
- Authors
- Sempionatto, J. R., Lin, M., Yin, L., De la paz, E., Pei, K., Sonsa-ard, T., de Loyola Silva, A. N., Khorshed, A. A., Zhang, F., Tostado, N., Xu, S., & Wang, J.
- Affiliations
- University of California San Diego (US)
- Corresponding author
- Xu, Sheng
- Wang, Joseph
- Venue
- Nature Biomedical Engineering
- Published
- 2021-02-15
- Volume
- 5
- Issue
- 7
- Pages
- 737-748
- ISSN
- 2157-846X (ISSN-L)
- OpenAlex
- W3132782516
- Cited by
- 658
- References
- 58
- Citations by year
- 2026: 87 · 2025: 139 · 2024: 133 · 2023: 128 · 2022: 115 · 2021: 56
- FWCI
- 32.81
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- www.springernature.com/gp/researchers/text-and-data-mining (tdm)
- www.springernature.com/gp/researchers/text-and-data-mining (vor)
- Locations
- Nature Biomedical Engineering (publishedVersion)
- Research Square (acceptedVersion, cc-by)
- PubMed (publishedVersion)
- Zenodo (CERN European Organization for Nuclear Research) (cc-by)
- Funders
- Ministry of Science, Technology and Innovation | Conselho Nacional de Desenvolvimento Científico e Tecnológico (216981/2014-0)
- University of California Institute for Mexico and the United States (2017-2022)
- Thailand Research Fund
- Fulbright Egyptian Scholar Program
- Foundation for the National Institutes of Health (1R21EB027303-01A1)
- UCSD Center of Wearable Sensors
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Keywords
- wearable sensors, blood pressure monitoring, heart rate monitoring, glucose detection, lactate sensing, alcohol detection, sweat biomarkers, interstitial glucose, ultrasonic transducers, electrochemical sensor, flexible electronics, dietary intake, physical activity, glycolysis
- MeSH terms
- Wearable Electronic Devices, Blood Pressure, Eating, Glucose, Heart Rate, Hemodynamics, Humans, Sweat, Biosensing Techniques, Biomarkers, Exercise, Lactic Acid, Electrochemical Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.