CoChat

Sampling of fluid through skin with magnetohydrodynamics for noninvasive glucose monitoring

Hakala, Tuuli A., García Pérez, Alejandro, Wardale, Melissa, Ruuth, Ida A., Vänskä, Risto T., Nurminen, Teemu A., Kemp, Emily, Boeva, Zhanna A., Alakoskela, Juha-Matti, Pettersson-Fernholm, Kim, Hæggström, Edward, Bobacka, Johan · 2021 · Scientific Reports
Cited by 32

The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.

Abstract

Out of 463 million people currently with diabetes, 232 million remain undiagnosed. Diabetes is a threat to human health, which could be mitigated via continuous self-monitoring of glucose. In addition to blood, interstitial fluid is considered to be a representative sample for glucose monitoring, which makes it highly attractive for wearable on-body sensing. However, new technologies are needed for efficient and noninvasive sampling of interstitial fluid through the skin. In this report, we introduce the use of Lorentz force and magnetohydrodynamics to noninvasively extract dermal interstitial fluid. Using porcine skin as an ex-vivo model, we demonstrate that the extraction rate of magnetohydrodynamics is superior to that of reverse iontophoresis. This work seeks to provide a safe, effective, and noninvasive sampling method to unlock the potential of wearable sensors in needle-free continuous glucose monitoring devices that can benefit people living with diabetes.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41598-021-86931-7

Cites

19 of 19 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 38

  1. IDF Atlas 9th edition (International Diabetes Foundation, Brussels, 2019). https://diabetesatlas.org/en/resources/. ISBN: 978-2-930229-87-4.
  2. Saeedi, P. et al. Global and regional diabetes prevalence estimates for 2019 and projections for 2030 and 2045: Results from the International Diabetes Federation Diabetes Atlas, 9th edition. Diabetes Res. Clin. Pract. 157, 107843 (2019). · DOI · Paper page
  3. DCCT Research Group. Diabetes control and complications trial (DCCT): Update. Diabetes Care 13, 427–433 (1990). · DOI · Paper page
  4. Wang, J. Electrochemical glucose biosensors. Chem. Rev. 108, 814–825 (2008). · DOI · Paper page
  5. Cefalu, W. T. et al. Update and next steps for real-world translation of interventions for type 2 diabetes prevention: Reflections from a diabetes care editors’ expert forum. Diabetes Care 39, 1186–1201 (2016). · DOI · Paper page
  6. Kim, J., Campbell, A. S., de Ávila, B. E. F. & Wang, J. Wearable biosensors for healthcare monitoring. Nat. Biotechnol. 37, 389–406 (2019). · DOI · Paper page
  7. Kim, J., Campbell, A. S. & Wang, J. Wearable non-invasive epidermal glucose sensors: A review. Talanta 177, 163–170 (2018). · DOI · Paper page
  8. Matzeu, G., Florea, L. & Diamond, D. Advances in wearable chemical sensor design for monitoring biological fluids. Sens. Actuators B Chem. 211, 403–418 (2015). · DOI · Paper page
  9. McCormick, C., Heath, D. & Connolly, P. Towards blood free measurement of glucose and potassium in humans using reverse iontophoresis. Sens. Actuators B Chem. 166–167, 593–600 (2012). · DOI
  10. Zhang, X. et al. Point-of-care diagnoses: Flexible patterning technique for self-powered wearable sensors. Anal. Chem. 90, 11780–11784 (2018). · DOI
  11. Zhu, X., Ju, Y., Chen, J., Liu, D. & Liu, H. Nonenzymatic wearable sensor for electrochemical analysis of perspiration glucose. ACS Sensors 3, 1135–1141 (2018). · DOI · Paper page
  12. Zhao, Y. et al. Highly stretchable and strain-insensitive fiber-based wearable electrochemical biosensor to monitor glucose in the sweat. Anal. Chem. 91, 6569–6576 (2019). · DOI · Paper page
  13. Gao, W., Ota, H., Kiriya, D., Takei, K. & Javey, A. Flexible electronics toward wearable sensing. Acc. Chem. Res. 52, 523–533 (2019). · DOI · Paper page
  14. Lee, S. J. et al. A patch type non-enzymatic biosensor based on 3D SUS micro-needle electrode array for minimally invasive continuous glucose monitoring. Sens. Actuators B Chem. 222, 1144–1151 (2016). · DOI
  15. Sharma, S. et al. A pilot study in humans of microneedle sensor arrays for continuous glucose monitoring. Anal. Methods 10, 2088–2095 (2018). · DOI · Paper page
  16. Zhu, J. et al. Gelatin methacryloyl microneedle patches for minimally invasive extraction of skin interstitial fluid. Small 16, 1905910 (2020). · DOI · Paper page
  17. Samant, P. P. & Prausnitz, M. R. Mechanisms of sampling interstitial fluid from skin using a microneedle patch. Proc. Natl. Acad. Sci. 115, 4583–4588 (2018). · DOI · Paper page
  18. Christodouleas, D. C., Kaur, B. & Chorti, P. From point-of-care testing to eHealth diagnostic devices (eDiagnostics). ACS Cent. Sci. 4, 1600–1616 (2018). · DOI · Paper page
  19. Lemoff, A. V. & Lee, A. P. AC magnetohydrodynamic micropump. Sensors Actuators B Chem. 63, 178–185 (2000). · DOI · Paper page
  20. Jang, J. & Lee, S. S. Theoretical and experimental study of MHD (magnetohydrodynamic) micropump. Sens. Actuators A Phys 80, 84–89 (2000). · doi:10.1016/s0924-4247(99)00302-7
  21. Das, C., Wang, G. & Payne, F. Some practical applications of magnetohydrodynamic pumping. Sens. Actuators A Phys 201, 43–48 (2013). · doi:10.1016/j.sna.2013.06.023
  22. Chang, J. H., Hogan, N. C. & Hunter, I. W. A needle-free technique for interstitial fluid sample acquisition using a Lorentz-force actuated jet injector. J. Control. Release 211, 37–43 (2015). · DOI
  23. Ching, C. T. S., Fu, L. S., Sun, T. P., Hsu, T. H. & Chang, K. M. Use of electroporation and reverse iontophoresis for extraction of transdermal multibiomarkers. Int. J. Nanomed. 7, 885–894 (2012). · doi:10.2147/ijn.s27421
  24. Debeer, S. et al. Comparative histology and immunohistochemistry of porcine versus human skin. Eur. J. Dermatol. 23, 456–466 (2013). · DOI · Paper page
  25. Sekkat, N., Kalia, Y. N. & Guy, R. H. Biophysical study of porcine ear skin in vitro and its comparison to human skin in vivo. J. Pharm. Sci. 91, 2376–2381 (2002). · DOI · Paper page
  26. Yue, K. et al. Synthesis, properties, and biomedical applications of gelatin methacryloyl (GelMA) hydrogels. Biomaterials 73, 254–271 (2015). · DOI · Paper page
  27. Ching, C. T. S., Chou, T. R., Sun, T. P., Huang, S. Y. & Shieh, H. L. Simultaneous, noninvasive, and transdermal extraction of urea and homocysteine by reverse iontophoresis. Int. J. Nanomed. 6, 417–423 (2011). · DOI
  28. Giri, T. K., Chakrabarty, S. & Ghosh, B. Transdermal reverse iontophoresis: A novel technique for therapeutic drug monitoring. J. Control. Release 246, 30–38 (2017). · DOI
  29. Potts, R. O., Tamada, J. A. & Tierney, M. J. Glucose monitoring by reverse iontophoresis. Diabetes Metab. Res. Rev. 18, S49–S53 (2002). · DOI · Paper page
  30. Rao, G. et al. Reverse iontophoresis: Noninvasive glucose monitoring in vivo in humans. Pharm. Res. 12, 1869–1873 (1995). · DOI
  31. Rao, G., Glikfeld, P. & Guy, R. H. Reverse iontophoresis: Development of a noninvasive approach for glucose monitoring. Pharm. Res. 10, 1751–1755 (1993). · DOI
  32. Leboulanger, B., Guy, R. H. & Delgado-Charro, M. B. Reverse iontophoresis for non-invasive transdermal monitoring. Physiol. Meas. 25, R35-50 (2004). · DOI · Paper page
  33. Varadharaj, E. K. & Jampana, N. Effect of potassium present in stratum corneum during non-invasive measurement of potassium in human subjects using reverse iontophoresis. Skin Res. Technol. 22, 89–97 (2016). · DOI
  34. Wascotte, V. et al. Monitoring of urea and potassium by reverse iontophoresis in vitro. Pharm. Res. 24, 1131–1137 (2007). · DOI
  35. Kalia, Y. N., Nonato, L. B. & Guy, R. H. The effect of iontophoresis on skin barrier integrity: Non-invasive evaluation by impedance spectroscopy and transepidermal water loss. Pharm. Res. 13, 957–960 (1996). · doi:10.1023/a:1016081902162
  36. Thysman, S., van Neste, D. & Préat, V. Noninvasive investigation of human skin after in vivo iontophoresis. Skin Pharmacol. Physiol. 8, 229–236 (1995). · doi:10.1159/000211352
  37. Pahoff, S. et al. Effect of gelatin source and photo initiator type on chondrocyte redifferentiation in gelatin methacryloyl-based tissue-engineered cartilage constructs. J. Mater. Chem. B 7, 1761–1772 (2019). · DOI
  38. Bergmeyer, H. U. & Bernt, E. Methods of Enzymatic Analysis 2nd edn. (Academic Press, 1974).

Cited by

See all 32

Metadata

Authors
Hakala, T. A., García Pérez, A., Wardale, M., Ruuth, I. A., Vänskä, R. T., Nurminen, T. A., Kemp, E., Boeva, Z. A., Alakoskela, J.-M., Pettersson-Fernholm, K., Hæggström, E., & Bobacka, J.
Venue
Scientific Reports
Published
2021-04-07
Volume
11
Issue
1
ISSN
2045-2322
Cited by
32
References
19
Language
en
Licence
Funders
  • Business Finland (1258/31/2016)
  • Academy of Finland (306041)

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.