The DOI matches its Crossref record; 81 of the 81 references it cites were found in a registry or an index.
A practical guide to microfluidic perfusion culture of adherent mammalian cells
Abstract
Culturing cells at microscales allows control over microenvironmental cues, such as cell-cell and cell-matrix interactions; the potential to scale experiments; the use of small culture volumes; and the ability to integrate with microsystem technologies for on-chip experimentation. Microfluidic perfusion culture in particular allows controlled delivery and removal of soluble biochemical molecules in the extracellular microenvironment, and controlled application of mechanical forces exerted via fluid flow. There are many challenges to designing and operating a robust microfluidic perfusion culture system for routine culture of adherent mammalian cells. The current literature on microfluidic perfusion culture treats microfluidic design, device fabrication, cell culture, and micro-assays independently. Here we systematically present and discuss important design considerations in the context of the entire microfluidic perfusion culture system. These design considerations include the choice of materials, culture configurations, microfluidic network fabrication and micro-assays. We also present technical issues such as sterilization; seeding cells in both 2D and 3D configurations; and operating the system under optimized mass transport and shear stress conditions, free of air-bubbles. The integrative and systematic treatment of the microfluidic system design and fabrication, cell culture, and micro-assays provides novices with an effective starting point to build and operate a robust microfludic perfusion culture system for various applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fabrication of microfluidic systems in poly(dimethylsiloxane)
McDonald, J. C., Duffy, D. C., Anderson, J. R., Chiu, D. T., Wu, H., Schueller, O. J. A., & Whitesides, G. M. (2000) · Electrophoresis · doi:10.1002/(sici)1522-2683(20000101)21:1<27::aid-elps27>3.0.co;2-c · Cited by 3,329
The Fluorescent Toolbox for Assessing Protein Location and Function
Giepmans, B. N. G., Adams, S. R., Ellisman, M. H., & Tsien, R. Y. (2006) · Science · doi:10.1126/science.1124618 · Cited by 2,770
Poly(dimethylsiloxane) as a Material for Fabricating Microfluidic Devices
McDonald, J. C., & Whitesides, G. M. (2002) · Accounts of Chemical Research · doi:10.1021/ar010110q · Cited by 2,454
Capturing complex 3D tissue physiology in vitro
Griffith, L. G., & Swartz, M. A. (2006) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm1858 · Cited by 2,290
Microfluidic Large-Scale Integration
Thorsen, T., Maerkl, S. J., & Quake, S. R. (2002) · Science · doi:10.1126/science.1076996 · Cited by 2,222
El-Ali, J., Sorger, P. K., & Jensen, K. F. (2006) · Nature · doi:10.1038/nature05063 · Cited by 2,102
Lab-on-a-chip: microfluidics in drug discovery
Dittrich, P. S., & Manz, A. (2006) · Nature Reviews Drug Discovery · doi:10.1038/nrd1985 · Cited by 1,844
Physics and Applications of Microfluidics in Biology
Beebe, D. J., Mensing, G. A., & Walker, G. M. (2002) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.4.112601.125916 · Cited by 1,800
Microfluidic devices fabricated in Poly(dimethylsiloxane) for biological studies
Sia, S. K., & Whitesides, G. M. (2003) · ELECTROPHORESIS · doi:10.1002/elps.200305584 · Cited by 1,717
Mediation of biomaterial-cell interactions by adsorbed proteins: a review
Wilson, C. J., Clegg, R. E., Leavesley, D. I., & Pearcy, M. J. (2005) · Tissue Engineering · doi:10.1089/ten.2005.11.1 · Cited by 1,696
Cited by
A guide to the organ-on-a-chip
Leung, C. M., de Haan, P., Ronaldson-Bouchard, K., Kim, G.-A., Ko, J., Rho, H. S., Chen, Z., Habibovic, P., Jeon, N. L., Takayama, S., et al. (2022) · Nature Reviews Methods Primers · doi:10.1038/s43586-022-00118-6 · Cited by 1,116
Self-citationAdvantages and challenges of microfluidic cell culture in polydimethylsiloxane devices
Halldorsson, S., Lucumi, E., Gómez-Sjöberg, R., & Fleming, R. M. T. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.07.029 · Cited by 1,027
Design of pressure-driven microfluidic networks using electric circuit analogy
Oh, K. W., Lee, K., Ahn, B., & Furlani, E. P. (2012) · Lab Chip · doi:10.1039/c2lc20799k · Cited by 685
Fundamentals of microfluidic cell culture in controlled microenvironments
Young, E. W. K., & Beebe, D. J. (2010) · Chemical Society Reviews · doi:10.1039/b909900j · Cited by 615
Microfluidic heart on a chip for higher throughput pharmacological studies
Agarwal, A., Goss, J. A., Cho, A., McCain, M. L., & Parker, K. K. (2013) · Lab on a Chip · doi:10.1039/c3lc50350j · Cited by 494
A microfluidic device for a pharmacokinetic–pharmacodynamic (PK–PD) model on a chip
Sung, J. H., Kam, C., & Shuler, M. L. (2010) · Lab on a Chip · doi:10.1039/b917763a · Cited by 484
Perfused multiwell plate for 3D liver tissue engineering
Domansky, K., Inman, W., Serdy, J., Dash, A., Lim, M. H. M., & Griffith, L. G. (2010) · Lab Chip · doi:10.1039/b913221j · Cited by 444
A microfluidic 3D hepatocyte chip for drug toxicity testing
Toh, Y.-C., Lim, T. C., Tai, D., Xiao, G., van Noort, D., & Yu, H. (2009) · Lab on a Chip · doi:10.1039/b900912d · Cited by 419
Self-citationCell Culture Models in Microfluidic Systems
Meyvantsson, I., & Beebe, D. J. (2008) · Annual Review of Analytical Chemistry · doi:10.1146/annurev.anchem.1.031207.113042 · Cited by 345
Acoustofluidics 12: Biocompatibility and cell viability in microfluidic acoustic resonators
Wiklund, M. (2012) · Lab on a Chip · doi:10.1039/c2lc40201g · Cited by 338
Marx, U. (2016) · ALTEX · doi:10.14573/altex.1603161 · Cited by 295
3D-printing of transparent bio-microfluidic devices in PEG-DA
Urrios, A., Parra-Cabrera, C., Bhattacharjee, N., Gonzalez-Suarez, A. M., Rigat-Brugarolas, L. G., Nallapatti, U., Samitier, J., DeForest, C. A., Posas, F., Garcia-Cordero, J. L., et al. (2016) · Lab on a Chip · doi:10.1039/c6lc00153j · Cited by 274
Moshksayan, K., Kashaninejad, N., Warkiani, M. E., Lock, J. G., Moghadas, H., Firoozabadi, B., Saidi, M. S., & Nguyen, N.-T. (2018) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2018.01.223 · Cited by 267
Flow-induced stress on adherent cells in microfluidic devices
Shemesh, J., Jalilian, I., Shi, A., Heng Yeoh, G., Knothe Tate, M. L., & Ebrahimi Warkiani, M. (2015) · Lab on a Chip · doi:10.1039/c5lc00633c · Cited by 144
Metabolic Patterning on a Chip: Towards in vitro Liver Zonation of Primary Rat and Human Hepatocytes
Kang, Y. B., Eo, J., Mert, S., Yarmush, M. L., & Usta, O. B. (2018) · Scientific Reports · doi:10.1038/s41598-018-27179-6 · Cited by 122
Microfluidic devices for in vitro studies on liver drug metabolism and toxicity
van Midwoud, P. M., Verpoorte, E., & Groothuis, G. M. M. (2011) · Integrative Biology · doi:10.1039/c0ib00119h · Cited by 115
Vacuum-assisted cell loading enables shear-free mammalian microfluidic culture
Kolnik, M., Tsimring, L. S., & Hasty, J. (2012) · Lab on a Chip · doi:10.1039/c2lc40569e · Cited by 86
Disease-on-a-chip: mimicry of tumor growth in mammary ducts
Vidi, P.-A., Maleki, T., Ochoa, M., Wang, L., Clark, S. M., Leary, J. F., & Lelièvre, S. A. (2014) · Lab Chip · doi:10.1039/c3lc50819f · Cited by 71
Study on Invadopodia Formation for Lung Carcinoma Invasion with a Microfluidic 3D Culture Device
Wang, S., Li, E., Gao, Y., Wang, Y., Guo, Z., He, J., Zhang, J., Gao, Z., & Wang, Q. (2013) · PLoS ONE · doi:10.1371/journal.pone.0056448 · Cited by 65
Teng, Y., Zhao, Z., Tasnim, F., Huang, X., & Yu, H. (2021) · Biomaterials · doi:10.1016/j.biomaterials.2021.120904 · Cited by 62
Self-citationSynthetic tumor networks for screening drug delivery systems
Prabhakarpandian, B., Shen, M.-C., Nichols, J. B., Garson, C. J., Mills, I. R., Matar, M. M., Fewell, J. G., & Pant, K. (2015) · Journal of Controlled Release · doi:10.1016/j.jconrel.2015.01.018 · Cited by 57
Microfluidic Biopsy Trapping Device for the Real-Time Monitoring of Tumor Microenvironment
Holton, A. B., Sinatra, F. L., Kreahling, J., Conway, A. J., Landis, D. A., & Altiok, S. (2017) · PLOS ONE · doi:10.1371/journal.pone.0169797 · Cited by 35
Al‐Abboodi, A., Tjeung, R., Doran, P. M., Yeo, L. Y., Friend, J., & Yik Chan, P. P. (2014) · Advanced Healthcare Materials · doi:10.1002/adhm.201400072 · Cited by 27
Advances in microfluidic 3D cell culture for preclinical drug development
(2022) · Progress in Molecular Biology and Translational Science · doi:10.1016/bs.pmbts.2021.07.022 · Cited by 23
Balakrishnan, S., Suma, M. S., Raju, S. R., Bhargav, S. D. B., Arunima, S., Das, S., & Ananthasuresh, G. K. (2015) · BioResearch open access · doi:10.1089/biores.2015.0024 · Cited by 20
Microfluidic Systems for Neural Cell Studies
Babaliari, E., Ranella, A., & Stratakis, E. (2023) · Bioengineering · doi:10.3390/bioengineering10080902 · Cited by 13
Application of Perfluoropolyether Elastomers in Microfluidic Drug Metabolism Assays
Wang, M., Tsuda, M., Deguchi, S., Higuchi, Y., So, K., Torisawa, Y.-S., Takayama, K., & Yamashita, F. (2022) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2022.122253 · Cited by 10
Metadata
- Authors
- Kim, L., Toh, Y.-C., Voldman, J., & Yu, H.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2007
- Volume
- 7
- Issue
- 6
- Pages
- 681
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2016915024
- Cited by
- 455
- References
- 81
- FWCI
- 21.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.