Droplet microfluidic technology for single-cell high-throughput screening
Open accessThe DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
We present a droplet-based microfluidic technology that enables high-throughput screening of single mammalian cells. This integrated platform allows for the encapsulation of single cells and reagents in independent aqueous microdroplets (1 pL to 10 nL volumes) dispersed in an immiscible carrier oil and enables the digital manipulation of these reactors at a very high-throughput. Here, we validate a full droplet screening workflow by conducting a droplet-based cytotoxicity screen. To perform this screen, we first developed a droplet viability assay that permits the quantitative scoring of cell viability and growth within intact droplets. Next, we demonstrated the high viability of encapsulated human monocytic U937 cells over a period of 4 days. Finally, we developed an optically-coded droplet library enabling the identification of the droplets composition during the assay read-out. Using the integrated droplet technology, we screened a drug library for its cytotoxic effect against U937 cells. Taken together our droplet microfluidic platform is modular, robust, uses no moving parts, and has a wide range of potential applications including high-throughput single-cell analyses, combinatorial screening, and facilitating small sample analyses.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Monolithic Microfabricated Valves and Pumps by Multilayer Soft Lithography
Unger, M. A., Chou, H.-P., Thorsen, T., Scherer, A., & Quake, S. R. (2000) · Science · doi:10.1126/science.288.5463.113 · Cited by 4,010
Quantum-dot-tagged microbeads for multiplexed optical coding of biomolecules
Han, M., Gao, X., Su, J. Z., & Nie, S. (2001) · Nature Biotechnology · doi:10.1038/90228 · Cited by 2,631
Formation of dispersions using “flow focusing” in microchannels
Anna, S. L., Bontoux, N., & Stone, H. A. (2003) · Applied Physics Letters · doi:10.1063/1.1537519 · Cited by 2,302
Dynamic Pattern Formation in a Vesicle-Generating Microfluidic Device
Thorsen, T., Roberts, R. W., Arnold, F. H., & Quake, S. R. (2001) · Physical Review Letters · doi:10.1103/physrevlett.86.4163 · Cited by 2,051
Reactions in Droplets in Microfluidic Channels
Song, H., Chen, D. L., & Ismagilov, R. F. (2006) · Angewandte Chemie International Edition · doi:10.1002/anie.200601554 · Cited by 1,847
A Microfluidic System for Controlling Reaction Networks in Time
Song, H., Tice, J. D., & Ismagilov, R. F. (2003) · Angewandte Chemie International Edition · doi:10.1002/anie.200390203 · Cited by 1,082
Micro/Nano encapsulation via electrified coaxial liquid jets
Loscertales, I. G., Barrero, A., Guerrero, I., Cortijo, R., Marquez, M., & Gañán-Calvo, A. M. (2002) · Science · doi:10.1126/science.1067595 · Cited by 1,017 · cited 1×
“For this study, we used a flow-focusing nozzle (20, 21) to encapsulate monocytic U937 cells into 700 pL ( 110 m) droplets at a rate of 100 droplets/s.”
MethodElectric Control of Droplets in Microfluidic Devices
Link, D. R., Grasland‐Mongrain, E., Duri, A., Sarrazin, F., Cheng, Z., Cristobal, G., Márquez, M., & Weitz, D. A. (2006) · Angewandte Chemie International Edition · doi:10.1002/anie.200503540 · Cited by 843
Self-citationMultifunctional Encoded Particles for High-Throughput Biomolecule Analysis
Pregibon, D. C., Toner, M., & Doyle, P. S. (2007) · Science · doi:10.1126/science.1134929 · Cited by 726
Clausell-Tormos, J., Lieber, D., Baret, J.-C., El-Harrak, A., Miller, O. J., Frenz, L., Blouwolff, J., Humphry, K. J., Köster, S., Duan, H., et al. (2008) · Chemistry & Biology · doi:10.1016/j.chembiol.2008.04.004 · Cited by 720
Cited by
Emerging Droplet Microfluidics
Shang, L., Cheng, Y., & Zhao, Y. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00848 · Cited by 1,584
Single-cell analysis and sorting using droplet-based microfluidics
Mazutis, L., Gilbert, J., Ung, W. L., Weitz, D. A., Griffiths, A. D., & Heyman, J. A. (2013) · Nature Protocols · doi:10.1038/nprot.2013.046 · Cited by 1,355
Microdroplets in Microfluidics: An Evolving Platform for Discoveries in Chemistry and Biology
Theberge, A. B., Courtois, F., Schaerli, Y., Fischlechner, M., Abell, C., Hollfelder, F., & Huck, W. T. S. (2010) · Angewandte Chemie International Edition · doi:10.1002/anie.200906653 · Cited by 1,059
Droplet microfluidics for high-throughput biological assays
Guo, M. T., Rotem, A., Heyman, J. A., & Weitz, D. A. (2012) · Lab on a Chip · doi:10.1039/c2lc21147e · Cited by 1,040
Microfluidic Bioprinting of Heterogeneous 3D Tissue Constructs Using Low‐Viscosity Bioink
Colosi, C., Shin, S. R., Manoharan, V., Massa, S., Costantini, M., Barbetta, A., Dokmeci, M. R., Dentini, M., & Khademhosseini, A. (2016) · Advanced Materials · doi:10.1002/adma.201503310 · Cited by 863
Single-cell barcoding and sequencing using droplet microfluidics
Zilionis, R., Nainys, J., Veres, A., Savova, V., Zemmour, D., Klein, A. M., & Mazutis, L. (2017) · Nature Protocols · doi:10.1038/nprot.2016.154 · Cited by 727
Surfactants in droplet-based microfluidics
Baret, J.-C. (2012) · Lab Chip · doi:10.1039/c1lc20582j · Cited by 649
Microfluidic Devices for Bioapplications
Yeo, L. Y., Chang, H., Chan, P. P. Y., & Friend, J. R. (2011) · Small · doi:10.1002/smll.201000946 · Cited by 622
Precision medicine for cancer with next-generation functional diagnostics
Friedman, A. A., Letai, A., Fisher, D. E., & Flaherty, K. T. (2015) · Nature Reviews Cancer · doi:10.1038/nrc4015 · Cited by 570
Luka, G., Ahmadi, A., Najjaran, H., Alocilja, E., DeRosa, M., Wolthers, K., Malki, A., Aziz, H., Althani, A., & Hoorfar, M. (2015) · Sensors · doi:10.3390/s151229783 · Cited by 566
Droplet Microfluidics—A Tool for Single‐Cell Analysis
Joensson, H. N., & Andersson Svahn, H. (2012) · Angewandte Chemie International Edition · doi:10.1002/anie.201200460 · Cited by 557
Quantitative and sensitive detection of rare mutations using droplet-based microfluidics
Pekin, D., Skhiri, Y., Baret, J.-C., Le Corre, D., Mazutis, L., Ben Salem, C., Millot, F., El Harrak, A., Hutchison, J. B., Larson, J. W., et al. (2011) · Lab on a Chip · doi:10.1039/c1lc20128j · Cited by 540
Self-citationScreening out irrelevant cell-based models of disease
Horvath, P., Aulner, N., Bickle, M., Davies, A. M., Nery, E. D., Ebner, D., Montoya, M. C., Östling, P., Pietiäinen, V., Price, L. S., et al. (2016) · Nature Reviews Drug Discovery · doi:10.1038/nrd.2016.175 · Cited by 525
Collins, D. J., Neild, A., deMello, A., Liu, A.-Q., & Ai, Y. (2015) · Lab on a Chip · doi:10.1039/c5lc00614g · Cited by 528
Single-cell analysis tools for drug discovery and development
Heath, J. R., Ribas, A., & Mischel, P. S. (2016) · Nature Reviews Drug Discovery · doi:10.1038/nrd.2015.16 · Cited by 473
“Several alternative approaches, typically with reduced levels of multiplexing, have been reported, including high-throughput microdroplet-based screening approaches 29,83–86 , some of which have been reviewed elsewhere 87 .”
Revisiting lab-on-a-chip technology for drug discovery
Neužil, P., Giselbrecht, S., Länge, K., Huang, T. J., & Manz, A. (2012) · Nature Reviews Drug Discovery · doi:10.1038/nrd3799 · Cited by 487
Technologies for Single-Cell Isolation
Gross, A., Schoendube, J., Zimmermann, S., Steeb, M., Zengerle, R., & Koltay, P. (2015) · International Journal of Molecular Sciences · doi:10.3390/ijms160816897 · Cited by 445
Microfluidics for single cell analysis
Yin, H., & Marshall, D. (2012) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2011.11.002 · Cited by 394
Yi, D., Bayer, T., Badenhorst, C. P. S., Wu, S., Doerr, M., Höhne, M., & Bornscheuer, U. T. (2021) · Chemical Society Reviews · doi:10.1039/d0cs01575j · Cited by 383
Shembekar, N., Chaipan, C., Utharala, R., & Merten, C. A. (2016) · Lab on a Chip · doi:10.1039/c6lc00249h · Cited by 372
Single-cell technologies for monitoring immune systems
Chattopadhyay, P. K., Gierahn, T. M., Roederer, M., & Love, J. C. (2014) · Nature Immunology · doi:10.1038/ni.2796 · Cited by 369
Analytical detection techniques for droplet microfluidics—A review
Zhu, Y., & Fang, Q. (2013) · Analytica Chimica Acta · doi:10.1016/j.aca.2013.04.064 · Cited by 365
Recent Advances in Droplet Microfluidics
Ding, Y., Howes, P. D., & deMello, A. J. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.9b05047 · Cited by 357
Droplet microfluidics: recent developments and future applications
Casadevall i Solvas, X., & deMello, A. (2011) · Chem. Commun. · doi:10.1039/c0cc02474k · Cited by 353
Profiling metabolites and peptides in single cells
Rubakhin, S. S., Romanova, E. V., Nemes, P., & Sweedler, J. V. (2011) · Nature Methods · doi:10.1038/nmeth.1549 · Cited by 347
Microfluidic Platforms for Single-Cell Analysis
Zare, R. N., & Kim, S. (2010) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-070909-105238 · Cited by 318
1-Million droplet array with wide-field fluorescence imaging for digital PCR
Hatch, A. C., Fisher, J. S., Tovar, A. R., Hsieh, A. T., Lin, R., Pentoney, S. L., Yang, D. L., & Lee, A. P. (2011) · Lab on a Chip · doi:10.1039/c1lc20561g · Cited by 317
3D-printed microfluidic devices: fabrication, advantages and limitations—a mini review
Chen, C., Mehl, B. T., Munshi, A. S., Townsend, A. D., Spence, D. M., & Martin, R. S. (2016) · Analytical Methods · doi:10.1039/c6ay01671e · Cited by 303
Kang, D.-K., Ali, M. M., Zhang, K., Huang, S. S., Peterson, E., Digman, M. A., Gratton, E., & Zhao, W. (2014) · Nature Communications · doi:10.1038/ncomms6427 · Cited by 297
Droplet digital PCR of viral DNA/RNA, current progress, challenges, and future perspectives
Kojabad, A. A., Farzanehpour, M., Galeh, H. E. G., Dorostkar, R., Jafarpour, A., Bolandian, M., & Nodooshan, M. M. (2021) · Journal of Medical Virology · doi:10.1002/jmv.26846 · Cited by 297
Single Cell Optical Imaging and Spectroscopy
Stender, A. S., Marchuk, K., Liu, C., Sander, S., Meyer, M. W., Smith, E. A., Neupane, B., Wang, G., Li, J., Cheng, J.-X., et al. (2013) · Chemical Reviews · doi:10.1021/cr300336e · Cited by 292
Advances in digital polymerase chain reaction (dPCR) and its emerging biomedical applications
Cao, L., Cui, X., Hu, J., Li, Z., Choi, J. R., Yang, Q., Lin, M., Ying Hui, L., & Xu, F. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.09.082 · Cited by 291
High-resolution dose–response screening using droplet-based microfluidics
Miller, O. J., Harrak, A. E., Mangeat, T., Baret, J.-C., Frenz, L., Debs, B. E., Mayot, E., Samuels, M. L., Rooney, E. K., Dieu, P., et al. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1113324109 · Cited by 286
Self-citationSingle‐Cell Analysis Using Droplet Microfluidics
Matuła, K., Rivello, F., & Huck, W. T. S. (2020) · Advanced Biosystems · doi:10.1002/adbi.201900188 · Cited by 277
Microfluidics for cell-based high throughput screening platforms—A review
Du, G., Fang, Q., & den Toonder, J. M. J. (2016) · Analytica Chimica Acta · doi:10.1016/j.aca.2015.11.023 · Cited by 276
“The throughput of microfluidic technology has been proven to reach the million level [58], however, the throughput is not the only limitation of microfluidic technology currently applied in drug discovery.”
Fallah-Araghi, A., Baret, J.-C., Ryckelynck, M., & Griffiths, A. D. (2012) · Lab on a Chip · doi:10.1039/c2lc21035e · Cited by 261
Overview of single-cell analyses: microdevices and applications
Lindström, S., & Andersson-Svahn, H. (2010) · Lab on a Chip · doi:10.1039/c0lc00150c · Cited by 260
Development and future of droplet microfluidics
Nan, L., Zhang, H., Weitz, D. A., & Shum, H. C. (2024) · Lab on a Chip · doi:10.1039/d3lc00729d · Cited by 253
Shen, F., Davydova, E. K., Du, W., Kreutz, J. E., Piepenburg, O., & Ismagilov, R. F. (2011) · Analytical Chemistry · doi:10.1021/ac200247e · Cited by 240
A Bioactive Carbon Nanotube‐Based Ink for Printing 2D and 3D Flexible Electronics
Shin, S. R., Farzad, R., Tamayol, A., Manoharan, V., Mostafalu, P., Zhang, Y. S., Akbari, M., Jung, S. M., Kim, D., Comotto, M., et al. (2016) · Advanced Materials · doi:10.1002/adma.201506420 · Cited by 236
High-Performance Single Cell Genetic Analysis Using Microfluidic Emulsion Generator Arrays
Zeng, Y., Novak, R., Shuga, J., Smith, M. T., & Mathies, R. A. (2010) · Analytical Chemistry · doi:10.1021/ac902683t · Cited by 232
Microfluidic single cell analysis: from promise to practice
Lecault, V., White, A. K., Singhal, A., & Hansen, C. L. (2012) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2012.03.022 · Cited by 229
Concentration gradient generation methods based on microfluidic systems
Wang, X., Liu, Z., & Pang, Y. (2017) · RSC Advances · doi:10.1039/c7ra04494a · Cited by 219
Lagus, T. P., & Edd, J. F. (2013) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/46/11/114005 · Cited by 213
“These include screening cells for enzyme activity [170], screening drug libraries for cytotoxicity [15] (figure 7) and screening engineered proteins for directed evolution [217].”
BackgroundPrinted droplet microfluidics for on demand dispensing of picoliter droplets and cells
Cole, R. H., Tang, S.-Y., Siltanen, C. A., Shahi, P., Zhang, J. Q., Poust, S., Gartner, Z. J., & Abate, A. R. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1704020114 · Cited by 204
“While in flowing droplet microfluidics it is possible to generate varying concentrations of reagents using oscillating flows or random droplet merger (16, 17), it is far more difficult to determine what was combined in each droplet afterwards, since they are not neatly stored on an array.”
BackgroundHuang, M., Bai, Y., Sjostrom, S. L., Hallström, B. M., Liu, Z., Petranovic, D., Uhlén, M., Joensson, H. N., Andersson-Svahn, H., & Nielsen, J. (2015) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1506460112 · Cited by 196
“Recently, droplet microfluidics-based cell sorting has emerged as a novel and powerful technology for high-throughput screening (6, 7).”
BackgroundMicrofluidic droplet handling by bulk acoustic wave (BAW) acoustophoresis
Leibacher, I., Reichert, P., & Dual, J. (2015) · Lab on a Chip · doi:10.1039/c5lc00083a · Cited by 192
High-throughput combinatorial cell co-culture using microfluidics
Tumarkin, E., Tzadu, L., Csaszar, E., Seo, M., Zhang, H., Lee, A., Peerani, R., Purpura, K., Zandstra, P. W., & Kumacheva, E. (2011) · Integrative Biology · doi:10.1039/c1ib00002k · Cited by 192
Miniaturization and Parallelization of Biological and Chemical Assays in Microfluidic Devices
Vyawahare, S., Griffiths, A. D., & Merten, C. A. (2010) · Chemistry & Biology · doi:10.1016/j.chembiol.2010.09.007 · Cited by 167
The Potential Impact of Droplet Microfluidics in Biology
Schneider, T., Kreutz, J., & Chiu, D. T. (2013) · Analytical Chemistry · doi:10.1021/ac400257c · Cited by 166
Recent advances in single cell manipulation and biochemical analysis on microfluidics
Gao, D., Jin, F., Zhou, M., & Jiang, Y. (2019) · The Analyst · doi:10.1039/c8an01186a · Cited by 161
Polymer-Based Microfluidic Devices for Pharmacy, Biology and Tissue Engineering
Alrifaiy, A., Lindahl, O. A., & Ramser, K. (2012) · Polymers · doi:10.3390/polym4031349 · Cited by 161
“Micro-beads composed of hydrogels, cells and test compounds have been produced in microfluidic systems with a stop-and-flow lithographic method or via microfluidic droplet generation [314,315].”
MethodDroplet-based single cell RNAseq tools: a practical guide
Salomon, R., Kaczorowski, D., Valdes-Mora, F., Nordon, R. E., Neild, A., Farbehi, N., Bartonicek, N., & Gallego-Ortega, D. (2019) · Lab on a Chip · doi:10.1039/c8lc01239c · Cited by 109
Microfluidic single-cell analysis for systems immunology
Junkin, M., & Tay, S. (2014) · Lab on a Chip · doi:10.1039/c3lc51182k · Cited by 96
Growth kinetics of microalgae in microfluidic static droplet arrays
Dewan, A., Kim, J., McLean, R. H., Vanapalli, S. A., & Karim, M. N. (2012) · Biotechnology and Bioengineering · doi:10.1002/bit.24568 · Cited by 92
“…studies have exploited microfluidic drops for analysis of single cells including bacteria (Huebner et al., 2007; Lee et al., 2006; Shim et al., 2009), mammalian (Brouzes et al., 2009), yeast (Falconnet et al., 2011; Kortmann et al., 2009; Koster et al., 2008), and algae cells (Pan et al., 2011).”
BackgroundControlled 3D culture in Matrigel microbeads to analyze clonal acinar development
Dolega, M. E., Abeille, F., Picollet-D'hahan, N., & Gidrol, X. (2015) · Biomaterials · doi:10.1016/j.biomaterials.2015.02.042 · Cited by 91
Single-cell screening of photosynthetic growth and lactate production by cyanobacteria
Hammar, P., Angermayr, S. A., Sjostrom, S. L., van der Meer, J., Hellingwerf, K. J., Hudson, E. P., & Joensson, H. N. (2015) · Biotechnology for Biofuels · doi:10.1186/s13068-015-0380-2 · Cited by 50
“The droplet platform also allows comparison of growth rates between different clones or strains [20, 21].”
Benz, C., Retzbach, H., Nagl, S., & Belder, D. (2013) · Lab on a Chip · doi:10.1039/c3lc00057e · Cited by 38
Sun, M., & Vanapalli, S. A. (2013) · Analytical Chemistry · doi:10.1021/ac303526y · Cited by 26
Zhu, Y., Li, J., Lin, X., Huang, X., & Hoffmann, M. R. (2021) · ACS Applied Bio Materials · doi:10.1021/acsabm.0c01615 · Cited by 18
Metadata
- Authors
- Brouzes, E., Medkova, M., Savenelli, N., Marran, D., Twardowski, M., Hutchison, J. B., Rothberg, J. M., Link, D. R., Perrimon, N., & Samuels, M. L.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2009-08-25
- Volume
- 106
- Issue
- 34
- Pages
- 14195-14200
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W1980221373
- Cited by
- 1,069
- References
- 34
- FWCI
- 38.63
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.