Biomimetic encoding model for restoring touch in bionic hands through a nerve interface
Open accessThe DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: Hand function can be restored in upper-limb amputees by equipping them with anthropomorphic prostheses controlled with signals from residual muscles. The dexterity of these bionic hands is severely limited in large part by the absence of tactile feedback about interactions with objects. We propose that, to the extent that artificial touch mimics its natural counterpart, these sensory signals will be more easily integrated into the motor plan for object manipulation. APPROACH: We describe an approach to convey tactile feedback through electrical stimulation of the residual somatosensory nerves that mimics the aggregate activity of tactile fibers that would be produced in the nerve of a native hand during object interactions. Specifically, we build a parsimonious model that maps the stimulus-described as time-varying indentation depth, indentation rate, and acceleration-into continuous estimates of the time-varying population firing rate and of the size of the recruited afferent population. MAIN RESULTS: The simple model can reconstruct aggregate afferent responses to a wide range of stimuli, including those experienced during activities of daily living. SIGNIFICANCE: We discuss how the proposed model can be implemented with a peripheral nerve interface and anticipate it will lead to improved dexterity for prosthetic hands.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Coding and use of tactile signals from the fingertips in object manipulation tasks
Johansson, R. S., & Flanagan, J. R. (2009) · Nature Reviews Neuroscience · doi:10.1038/nrn2621 · Cited by 2,063
Restoring natural sensory feedback in real-time bidirectional hand prostheses
Raspopovic, S., Capogrosso, M., Petrini, F. M., Bonizzato, M., Rigosa, J., Di Pino, G., Carpaneto, J., Controzzi, M., Boretius, T., Fernandez, E., et al. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3006820 · Cited by 1,001 · cited 3×
“…and demonstrate that it far outperforms more traditional sensory encoding algorithms in reconstructing the nerve activity evoked during activities of daily living (Gurpreet Singh Dhillon and Horch 2005, Clark et al 2014, Raspopovic 2014, Tan et al 2014, Graczyk et al 2016, Schiefer et al 2016).”
BackgroundInfluentialA neural interface provides long-term stable natural touch perception
Tan, D. W., Schiefer, M. A., Keith, M. W., Anderson, J. R., Tyler, J., & Tyler, D. J. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3008669 · Cited by 751
Direct neural sensory feedback and control of a prosthetic arm
Dhillon, G. S., & Horch, K. W. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.856072 · Cited by 573
A transverse intrafascicular multichannel electrode (TIME) to interface with the peripheral nerve
Boretius, T., Badia, J., Pascual-Font, A., Schuettler, M., Navarro, X., Yoshida, K., & Stieglitz, T. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.05.010 · Cited by 468
Spatial and temporal codes mediate the tactile perception of natural textures
Weber, A. I., Saal, H. P., Lieber, J. D., Cheng, J.-W., Manfredi, L. R., Dammann, J. F., & Bensmaia, S. J. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1305509110 · Cited by 421
Functionally selective peripheral nerve stimulation with a flat interface nerve electrode
Tyler, D. J., & Durand, D. M. (2002) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2002.806840 · Cited by 398
Restoring sensorimotor function through intracortical interfaces: progress and looming challenges
Bensmaia, S. J., & Miller, L. E. (2014) · Nature Reviews Neuroscience · doi:10.1038/nrn3724 · Cited by 368
Dhillon, G. S., Lawrence, S. M., Hutchinson, D. T., & Horch, K. W. (2004) · The Journal of Hand Surgery · doi:10.1016/j.jhsa.2004.02.006 · Cited by 354
Robotic touch shifts perception of embodiment to a prosthesis in targeted reinnervation amputees
Marasco, P. D., Kim, K., Colgate, J. E., Peshkin, M. A., & Kuiken, T. A. (2011) · Brain · doi:10.1093/brain/awq361 · Cited by 335
Touch is a team effort: interplay of submodalities in cutaneous sensibility
Saal, H. P., & Bensmaia, S. J. (2014) · Trends in Neurosciences · doi:10.1016/j.tins.2014.08.012 · Cited by 280
The neural basis of perceived intensity in natural and artificial touch
Graczyk, E. L., Schiefer, M. A., Saal, H. P., Delhaye, B. P., Bensmaia, S. J., & Tyler, D. J. (2016) · Science Translational Medicine · doi:10.1126/scitranslmed.aaf5187 · Cited by 258
Schiefer, M., Tan, D., Sidek, S. M., & Tyler, D. J. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/1/016001 · Cited by 255
Muniak, M. A., Ray, S., Hsiao, S. S., Dammann, J. F., & Bensmaia, S. J. (2007) · The Journal of Neuroscience · doi:10.1523/jneurosci.1486-07.2007 · Cited by 235
The cutaneous contribution to adaptive precision grip
Witney, A. G., Wing, A., Thonnard, J.-L., & Smith, A. M. (2004) · Trends in Neurosciences · doi:10.1016/j.tins.2004.08.006 · Cited by 203
Biomimetic approaches to bionic touch through a peripheral nerve interface
Saal, H. P., & Bensmaia, S. J. (2015) · Neuropsychologia · doi:10.1016/j.neuropsychologia.2015.06.010 · Cited by 179
Self-citationMillisecond precision spike timing shapes tactile perception
Mackevicius, E. L., Best, M. D., Saal, H. P., & Bensmaia, S. J. (2012) · The Journal of Neuroscience · doi:10.1523/jneurosci.2161-12.2012 · Cited by 171
Fascicular perineurium thickness, size, and position affect model predictions of neural excitation
Grinberg, Y., Schiefer, M. A., Tyler, D. J., & Gustafson, K. J. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.2010348 · Cited by 145
The effect of surface wave propagation on neural responses to vibration in primate glabrous skin
Manfredi, L. R., Baker, A. T., Elias, D. O., Dammann, J. F., Zielinski, M. C., Polashock, V. S., & Bensmaia, S. J. (2012) · PLoS ONE · doi:10.1371/journal.pone.0031203 · Cited by 117
Gustafson, K. J., Pinault, G. C. J., Neville, J. J., Syed, I., Jr, J. A. D., Jean-Claude, J., & Triolo, R. J. (2009) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2008.08.0097 · Cited by 107
Clark, G. A., Wendelken, S., Page, D. M., Davis, T., Wark, H. A. C., Normann, R. A., Warren, D. J., & Hutchinson, D. T. (2014) · 2014 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/embc.2014.6944001 · Cited by 78 · cited 1×
“In the majority of sensory feedback algorithms implemented to date in experiments with human amputees (see Dhillon and Horch (2005), Clark et al (2014), Raspopovic (2014), Tan et al (2014), Graczyk et al (2016) and Schiefer et al (2016)), the firing rate of the nerve F̂Rt linearly tracks the…”
Intrafascicular stimulation of monkey arm nerves evokes coordinated grasp and sensory responses
Ledbetter, N. M., Ethier, C., Oby, E. R., Hiatt, S. D., Wilder, A. M., Ko, J. H., Agnew, S. P., Miller, L. E., & Clark, G. A. (2013) · Journal of Neurophysiology · doi:10.1152/jn.00688.2011 · Cited by 69
Quantification of human upper extremity nerves and fascicular anatomy
Brill, N. A., & Tyler, D. J. (2017) · Muscle & Nerve · doi:10.1002/mus.25534 · Cited by 64 · cited 1×
“In many cases, spatial factors are idiosyncratic and must be assessed on a subject by subject basis, for example, the distribution of nerve fascicles at the current injection site and the geometry of the channel rela tive to the nerve fibers (Gustafson et al 2009, Brill and Tyler 2011, 2017).”
Chronic Measurement of the Stimulation Selectivity of the Flat Interface Nerve Electrode
Leventhal, D. K., & Durand, D. M. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.827535 · Cited by 55
A simple model of mechanotransduction in primate glabrous skin
Dong, Y., Mihalas, S., Kim, S. S., Yoshioka, T., Bensmaia, S., & Niebur, E. (2013) · Journal of Neurophysiology · doi:10.1152/jn.00395.2012 · Cited by 47
Cited by
George, J. A., Kluger, D. T., Davis, T. S., Wendelken, S. M., Okorokova, E. V., He, Q., Duncan, C. C., Hutchinson, D. T., Thumser, Z. C., Beckler, D. T., et al. (2019) · Science Robotics · doi:10.1126/scirobotics.aax2352 · Cited by 388
Self-citationEnhancing functional abilities and cognitive integration of the lower limb prosthesis
Petrini, F. M., Valle, G., Bumbasirevic, M., Barberi, F., Bortolotti, D., Cvancara, P., Hiairrassary, A., Mijovic, P., Sverrisson, A. Ö., Pedrocchi, A., et al. (2019) · Science Translational Medicine · doi:10.1126/scitranslmed.aav8939 · Cited by 265
Restoration of sensory information via bionic hands
Bensmaia, S. J., Tyler, D. J., & Micera, S. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-020-00630-8 · Cited by 257
Self-citationThe neural mechanisms of manual dexterity
Sobinov, A. R., & Bensmaia, S. J. (2021) · Nature Reviews Neuroscience · doi:10.1038/s41583-021-00528-7 · Cited by 248
Sensitivity to temporal parameters of intraneural tactile sensory feedback
Valle, G., Strauss, I., D’Anna, E., Granata, G., Di Iorio, R., Stieglitz, T., Rossini, P. M., Raspopovic, S., Petrini, F. M., & Micera, S. (2020) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-020-00737-8 · Cited by 20
Metadata
- Authors
- Okorokova, E. V., He, Q., & Bensmaia, S. J.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2018-10-31
- Volume
- 15
- Issue
- 6
- Pages
- 066033
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2892583765
- Cited by
- 94
- References
- 25
- FWCI
- 3.60
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.