An implantable wireless neural interface for recording cortical circuit dynamics in moving primates
Open accessThe DOI matches its Crossref record; 59 of the 59 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: Neural interface technology suitable for clinical translation has the potential to significantly impact the lives of amputees, spinal cord injury victims and those living with severe neuromotor disease. Such systems must be chronically safe, durable and effective. APPROACH: We have designed and implemented a neural interface microsystem, housed in a compact, subcutaneous and hermetically sealed titanium enclosure. The implanted device interfaces the brain with a 510k-approved, 100-element silicon-based microelectrode array via a custom hermetic feedthrough design. Full spectrum neural signals were amplified (0.1 Hz to 7.8 kHz, 200× gain) and multiplexed by a custom application specific integrated circuit, digitized and then packaged for transmission. The neural data (24 Mbps) were transmitted by a wireless data link carried on a frequency-shift-key-modulated signal at 3.2 and 3.8 GHz to a receiver 1 m away by design as a point-to-point communication link for human clinical use. The system was powered by an embedded medical grade rechargeable Li-ion battery for 7 h continuous operation between recharge via an inductive transcutaneous wireless power link at 2 MHz. MAIN RESULTS: Device verification and early validation were performed in both swine and non-human primate freely-moving animal models and showed that the wireless implant was electrically stable, effective in capturing and delivering broadband neural data, and safe for over one year of testing. In addition, we have used the multichannel data from these mobile animal models to demonstrate the ability to decode neural population dynamics associated with motor activity. SIGNIFICANCE: We have developed an implanted wireless broadband neural recording device evaluated in non-human primate and swine. The use of this new implantable neural interface technology can provide insight into how to advance human neuroprostheses beyond the present early clinical trials. Further, such tools enable mobile patient use, have the potential for wider diagnosis of neurological conditions and will advance brain research.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Analysis of Tissue and Arterial Blood Temperatures in the Resting Human Forearm
Pennes, H. H. (1998) · Journal of Applied Physiology · doi:10.1152/jappl.1998.85.1.5 · Cited by 3,982
Neuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295
Reach and grasp by people with tetraplegia using a neurally controlled robotic arm
Hochberg, L. R., Bacher, D., Jarosiewicz, B., Masse, N. Y., Simeral, J. D., Vogel, J., Haddadin, S., Liu, J., Cash, S. S., van der Smagt, P., et al. (2012) · Nature · doi:10.1038/nature11076 · Cited by 2,719
A low-power low-noise cmos for amplifier neural recording applications
Harrison, R. R., & Charles, C. (2003) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2003.811979 · Cited by 1,695
Cortical control of a prosthetic arm for self-feeding
Velliste, M., Perel, S., Spalding, M. C., Whitford, A. S., & Schwartz, A. B. (2008) · Nature · doi:10.1038/nature06996 · Cited by 1,591
Better speech recognition with cochlear implants
Wilson, B. S., Finley, C. C., Lawson, D. T., Wolford, R. D., Eddington, D. K., & Rabinowitz, W. M. (1991) · Nature · doi:10.1038/352236a0 · Cited by 1,190
A brain–computer interface using electrocorticographic signals in humans
Leuthardt, E. C., Schalk, G., Wolpaw, J. R., Ojemann, J. G., & Moran, D. W. (2004) · Journal of Neural Engineering · doi:10.1088/1741-2560/1/2/001 · Cited by 1,188
Chronic, multisite, multielectrode recordings in macaque monkeys
Nicolelis, M. A. L., Dimitrov, D., Carmena, J. M., Crist, R., Lehew, G., Kralik, J. D., & Wise, S. P. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1934665100 · Cited by 740
Yu, B. M., Cunningham, J. P., Santhanam, G., Ryu, S. I., Shenoy, K. V., & Sahani, M. (2009) · Journal of Neurophysiology · doi:10.1152/jn.90941.2008 · Cited by 656
Chronic recording capability of the Utah Intracortical Electrode Array in cat sensory cortex
Rousche, P. J., & Normann, R. A. (1998) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(98)00031-4 · Cited by 646
Epilepsy as a Disorder of Cortical Network Organization
Kramer, M. A., & Cash, S. S. (2012) · The Neuroscientist · doi:10.1177/1073858411422754 · Cited by 572
The use of pigs in neuroscience: Modeling brain disorders
Lind, N. M., Moustgaard, A., Jelsing, J., Vajta, G., Cumming, P., & Hansen, A. K. (2007) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2007.02.003 · Cited by 515
Single-neuron dynamics in human focal epilepsy
Truccolo, W., Donoghue, J. A., Hochberg, L. R., Eskandar, E. N., Madsen, J. R., Anderson, W. S., Brown, E. N., Halgren, E., & Cash, S. S. (2011) · Nature Neuroscience · doi:10.1038/nn.2782 · Cited by 514
Simeral, J. D., Kim, S.-P., Black, M. J., Donoghue, J. P., & Hochberg, L. R. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/2/025027 · Cited by 496
Denison, T., Consoer, K., Santa, W., Avestruz, A.-T., Cooley, J., & Kelly, A. (2007) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2007.908664 · Cited by 451
Heat Transfer in Medicine and Biology: Analysis and Applications. Volume 2
Shitzer, A., & Eberhart, R. C. (1985) · Springer eBooks · doi:10.1007/978-1-4684-8285-0 · Cited by 436
Suner, S., Fellows, M. R., Vargas-Irwin, C., Nakata, G. K., & Donoghue, J. P. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.857687 · Cited by 415
A 128-Channel 6 mW Wireless Neural Recording IC With Spike Feature Extraction and UWB Transmitter
Chae, M. S., Yang, Z., Yuce, M. R., Hoang, L., & Liu, W. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2021607 · Cited by 369 · cited 1×
“Examples of advances at the subsystem microchip electronics level include powerful digital signal processors [17, 32, 33] that feed digitized multichannel neural data to on-board radio-frequency transmitters [12,34,35].”
BackgroundSingle unit recording capabilities of a 100 microelectrode array
Nordhausen, C. T., Maynard, E. M., & Normann, R. A. (1996) · Brain Research · doi:10.1016/0006-8993(96)00321-6 · Cited by 358
A glass/silicon composite intracortical electrode array
Jones, K. E., Campbell, P. K., & Normann, R. A. (1992) · Annals of Biomedical Engineering · doi:10.1007/bf02368134 · Cited by 354
Congruent Activity during Action and Action Observation in Motor Cortex
Tkach, D., Reimer, J., & Hatsopoulos, N. G. (2007) · The Journal of Neuroscience · doi:10.1523/jneurosci.2895-07.2007 · Cited by 297
Primary Motor Cortex Tuning to Intended Movement Kinematics in Humans with Tetraplegia
Truccolo, W., Friehs, G. M., Donoghue, J. P., & Hochberg, L. R. (2008) · The Journal of Neuroscience · doi:10.1523/jneurosci.4415-07.2008 · Cited by 272
Decoding Complete Reach and Grasp Actions from Local Primary Motor Cortex Populations
Vargas-Irwin, C. E., Shakhnarovich, G., Yadollahpour, P., Mislow, J. M. K., Black, M. J., & Donoghue, J. P. (2010) · Journal of Neuroscience · doi:10.1523/jneurosci.5443-09.2010 · Cited by 268
Single-Trial Neural Correlates of Arm Movement Preparation
Afshar, A., Santhanam, G., Yu, B. M., Ryu, S. I., Sahani, M., & Shenoy, K. V. (2011) · Neuron · doi:10.1016/j.neuron.2011.05.047 · Cited by 255
Wireless Neural Recording With Single Low-Power Integrated Circuit
Harrison, R. R., Kier, R. J., Chestek, C. A., Gilja, V., Nuyujukian, P., Ryu, S., Greger, B., Solzbacher, F., & Shenoy, K. V. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2023298 · Cited by 209
A wireless multi-channel neural amplifier for freely moving animals
Szuts, T. A., Fadeyev, V., Kachiguine, S., Sher, A., Grivich, M. V., Agrochão, M., Hottowy, P., Dabrowski, W., Lubenov, E. V., Siapas, A. G., et al. (2011) · Nature Neuroscience · doi:10.1038/nn.2730 · Cited by 183
Temperature Changes in Blood Flowing in Arteries and Veins in Man
Bazett, H. C., Love, L., Newton, M., Eisenberg, L., Day, R., & Forster, R. (1948) · Journal of Applied Physiology · doi:10.1152/jappl.1948.1.1.3 · Cited by 172
A 100-Channel Hermetically Sealed Implantable Device for Chronic Wireless Neurosensing Applications
Yin, M., Borton, D. A., Aceros, J., Patterson, W. R., & Nurmikko, A. V. (2013) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2013.2255874 · Cited by 165
Self-citationCorrelation of thermal properties of some human tissue with water content.
Cooper, T., & Trezek, G. J. (1971) · PubMed · Cited by 162
Miranda, H., Gilja, V., Chestek, C. A., Shenoy, K. V., & Meng, T. H. (2010) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2010.2044573 · Cited by 161
Bansal, A. K., Vargas-Irwin, C. E., Truccolo, W., & Donoghue, J. P. (2011) · Journal of Neurophysiology · doi:10.1152/jn.00532.2010 · Cited by 148
Choi, J. H., Jung, H., & Kim, T. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.870239 · Cited by 145
HermesC: Low-Power Wireless Neural Recording System for Freely Moving Primates
Chestek, C. A., Gilja, V., Nuyujukian, P., Kier, R. J., Solzbacher, F., Ryu, S. I., Harrison, R. R., & Shenoy, K. V. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2023293 · Cited by 130
Chase, S. M., Kass, R. E., & Schwartz, A. B. (2012) · Journal of Neurophysiology · doi:10.1152/jn.00371.2011 · Cited by 127
Nurmikko, A. V., Donoghue, J. P., Hochberg, L. R., Patterson, W. R., Song, Y.-K., Bull, C. W., Borton, D. A., Laiwalla, F., Park, S., Ming, Y., et al. (2010) · Proceedings of the IEEE · doi:10.1109/jproc.2009.2038949 · Cited by 127
Self-citationFactor-Analysis Methods for Higher-Performance Neural Prostheses
Santhanam, G., Yu, B. M., Gilja, V., Ryu, S. I., Afshar, A., Sahani, M., & Shenoy, K. V. (2009) · Journal of Neurophysiology · doi:10.1152/jn.00097.2009 · Cited by 116
Continuous neuronal ensemble control of simulated arm reaching by a human with tetraplegia
Chadwick, E. K., Blana, D., Simeral, J. D., Lambrecht, J., Kim, S. P., Cornwell, A. S., Taylor, D. M., Hochberg, L. R., Donoghue, J. P., & Kirsch, R. F. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/3/034003 · Cited by 109
Human cortical prostheses: lost in translation?
Ryu, S. I., & Shenoy, K. V. (2009) · Neurosurgical Focus · doi:10.3171/2009.4.focus0987 · Cited by 104
A Microelectrode/Microelectronic Hybrid Device for Brain Implantable Neuroprosthesis Applications
Patterson, W. R., Song, Y.-K., Bull, C. W., Ozden, I., Deangellis, A. P., Lay, C., McKay, J. L., Nurmikko, A. V., Donoghue, J. D., & Connors, B. W. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.831521 · Cited by 100
Self-citationEncoding of Coordinated Reach and Grasp Trajectories in Primary Motor Cortex
Saleh, M., Takahashi, K., & Hatsopoulos, N. G. (2012) · Journal of Neuroscience · doi:10.1523/jneurosci.2438-11.2012 · Cited by 97
Active Microelectronic Neurosensor Arrays for Implantable Brain Communication Interfaces
Song, Y.-K., Borton, D. A., Park, S., Patterson, W. R., Bull, C. W., Laiwalla, F., Mislow, J., Simeral, J. D., Donoghue, J. P., & Nurmikko, A. V. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2024310 · Cited by 95
Self-citationA Wireless Implantable Microsystem for Multichannel Neural Recording
Sodagar, A. M., Wise, K. D., & Najafi, K. (2009) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2009.2029957 · Cited by 90
A fully implantable 96-channel neural data acquisition system
Rizk, M., Bossetti, C. A., Jochum, T. A., Callender, S. H., Nicolelis, M. A. L., Turner, D. A., & Wolf, P. D. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/2/026002 · Cited by 89
A miniaturized neuroprosthesis suitable for implantation into the brain
Mojarradi, M. M., Binkley, D. M., Blalock, B. J., Andersen, R. A., Ulshoefer, N., Johnson, T., & Castillo, L. D. (2003) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.810431 · Cited by 88
Rizk, M., Obeid, I., Callender, S. H., & Wolf, P. D. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/3/016 · Cited by 71
Free-paced high-performance brain–computer interfaces
Achtman, N., Afshar, A., Santhanam, G., Yu, B. M., Ryu, S. I., & Shenoy, K. V. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/3/018 · Cited by 70
The challenge of integrating devices into the central nervous system.
Tresco, P. A., & Winslow, B. D. (2011) · Critical Reviews™ in Biomedical Engineering · doi:10.1615/critrevbiomedeng.v39.i1.30 · Cited by 65
Yin, M., & Ghovanloo, M. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2023302 · Cited by 40
Self-citationKim, S.-P., Simeral, J. D., Hochberg, L. R., Donoghue, J. P., Friehs, G. M., & Black, M. J. (2007) · 2007 3rd International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/cne.2007.369715 · Cited by 37
Miranda, H. C., & Meng, T. H. Y. (2010) · Custom Integrated Circuits Conference · doi:10.1109/cicc.2010.5617608 · Cited by 35
Yin, M., & Ghovanloo, M. (2010) · Analog Integrated Circuits and Signal Processing · doi:10.1007/s10470-010-9557-6 · Cited by 27
Self-citationA clockless ultra low-noise low-power wireless implantable neural recording system
Yin, M., & Ghovanloo, M. (2008) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2008.4541778 · Cited by 21
Self-citationA 100-channel hermetically sealed implantable device for wireless neurosensing applications
Yin, M., Borton, D. A., Aceros, J. C., Patterson, W. R., & Nurmikko, A. V. (2012) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2012.6271845 · Cited by 19
Self-citationDeveloping implantable neuroprosthetics: A new model in pig
Borton, D. A., Yin, M., Aceros, J. C., Agha, N. S., Minxha, J., Komar, J., Patterson, W., Bull, C. W., & Nurmikko, A. V. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6090828 · Cited by 17
Self-citationA penetrating, cortical electrode array: design considerations
Normann, R. A. (2002) · Conference proceedings/Conference proceedings - IEEE International Conference on Systems, Man, and Cybernetics · doi:10.1109/icsmc.1990.142258 · Cited by 15
Aceros, J. C., Yin, M., Borton, D. A., Patterson, W. R., & Nurmikko, A. V. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6090579 · Cited by 14
Self-citationA statistical description of neural ensemble dynamics
Long, J. D., & Carmena, J. M. (2011) · Frontiers in Computational Neuroscience · doi:10.3389/fncom.2011.00052 · Cited by 11
Afshar, P., Moran, D. W., Rouse, A. G., Wei, X., & Denison, T. (2011) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2011.5910645 · Cited by 10
An 8μW Heterodyning Chopper Amplifier for Direct Extraction of 2μVrms Neuronal Biomarkers
Denison, T., Santa, W., Jensen, R. M., Carlson, D., Molnar, G. F., & Avestruz, A.-T. (2008) · Digest of technical papers/Digest of technical papers - IEEE International Solid-State Circuits Conference · doi:10.1109/isscc.2008.4523107 · Cited by 9
Cited by
Failure mode analysis of silicon-based intracortical microelectrode arrays in non-human primates
Barrese, J. C., Rao, N., Paroo, K., Triebwasser, C., Vargas-Irwin, C., Franquemont, L., & Donoghue, J. P. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/6/066014 · Cited by 600
Pandarinath, C., Nuyujukian, P., Blabe, C. H., Sorice, B. L., Saab, J., Willett, F. R., Hochberg, L. R., Shenoy, K. V., & Henderson, J. M. (2017) · eLife · doi:10.7554/elife.18554 · Cited by 566
“Such a system may be achievable by combining the advances in this report with previous advances in self-calibration and in fully-implantable wireless interfaces ( Jarosiewicz et al., 2015 ; Borton et al., 2013 ).”
MethodWireless Power Transfer Strategies for Implantable Bioelectronics
Agarwal, K., Jegadeesan, R., Guo, Y.-X., & Thakor, N. V. (2017) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2017.2683520 · Cited by 540
A Materials Roadmap to Functional Neural Interface Design
Wellman, S. M., Eles, J. R., Ludwig, K. A., Seymour, J. P., Michelson, N. J., McFadden, W. E., Vazquez, A. L., & Kozai, T. D. Y. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201701269 · Cited by 389
Restoring sensorimotor function through intracortical interfaces: progress and looming challenges
Bensmaia, S. J., & Miller, L. E. (2014) · Nature Reviews Neuroscience · doi:10.1038/nrn3724 · Cited by 368
Metadata
- Authors
- Borton, D. A., Yin, M., Aceros, J., & Nurmikko, A.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2013-02-21
- Volume
- 10
- Issue
- 2
- Pages
- 026010
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2075351013
- Cited by
- 321
- References
- 59
- FWCI
- 15.44
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.