Comparing temporal aspects of visual, tactile, and microstimulation feedback for motor control
Open accessThe DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Abstract
OBJECTIVES: Current brain-computer interfaces (BCIs) rely on visual feedback, requiring sustained visual attention to use the device. Improvements to BCIs may stem from the development of an effective way to provide quick feedback independent of vision. Tactile stimuli, either delivered on the skin surface, or directly to the brain via microstimulation in somatosensory cortex, could serve that purpose. We examined the effectiveness of vibrotactile stimuli and microstimulation as a means of non-visual feedback by using a fundamental element of feedback: the ability to react to a stimulus while already in motion. APPROACH: Human and monkey subjects performed a center-out reach task which was, on occasion, interrupted with a stimulus cue that instructed a change in reach target. MAIN RESULTS: Subjects generally responded faster to tactile cues than to visual cues. However, when we delivered cues via microstimuation in a monkey, its response was slower on average than for both tactile and visual cues. SIGNIFICANCE: Tactile and microstimulation feedback can be used to rapidly adjust movements mid-flight. The relatively slow speed of microstimulation is surprising and warrants further investigation. Overall, these results highlight the importance of considering temporal aspects of feedback when designing alternative forms of feedback for BCIs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Neuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295 · cited 1×
“BCI control has been demonstrated in sophisticated behaviors such as point-and-click cursor control [5, 6, 7, 8, 9, 10, 11, 12, 13], use of a robotic arm [14, 15, 16, 17, 18], and the voluntary control of paralyzed muscles [19, 20, 21].”
BackgroundReach and grasp by people with tetraplegia using a neurally controlled robotic arm
Hochberg, L. R., Bacher, D., Jarosiewicz, B., Masse, N. Y., Simeral, J. D., Vogel, J., Haddadin, S., Liu, J., Cash, S. S., van der Smagt, P., et al. (2012) · Nature · doi:10.1038/nature11076 · Cited by 2,719 · cited 1×
“BCI control has been demonstrated in sophisticated behaviors such as point-and-click cursor control [5, 6, 7, 8, 9, 10, 11, 12, 13], use of a robotic arm [14, 15, 16, 17, 18], and the voluntary control of paralyzed muscles [19, 20, 21].”
BackgroundCoding and use of tactile signals from the fingertips in object manipulation tasks
Johansson, R. S., & Flanagan, J. R. (2009) · Nature Reviews Neuroscience · doi:10.1038/nrn2621 · Cited by 2,063
Which elements are excited in electrical stimulation of mammalian central nervous system: A review
Ranck, J. B. (1975) · Brain Research · doi:10.1016/0006-8993(75)90364-9 · Cited by 2,024
High-performance neuroprosthetic control by an individual with tetraplegia
Collinger, J. L., Wodlinger, B., Downey, J. E., Wang, W., Tyler-Kabara, E. C., Weber, D. J., McMorland, A. J., Velliste, M., Boninger, M. L., & Schwartz, A. B. (2013) · The Lancet · doi:10.1016/s0140-6736(12)61816-9 · Cited by 1,848
Learning to control a brain–machine interface for reaching and grasping by primates
Carmena, J. M., Lebedev, M. A., Crist, R. E., O'Doherty, J. E., Santucci, D. M., Dimitrov, D. F., Patil, P. G., Henriquez, C. S., & Nicolelis, M. A. L. (2003) · PLoS Biology · doi:10.1371/journal.pbio.0000042 · Cited by 1,761 · cited 1×
“BCI control has been demonstrated in sophisticated behaviors such as point-and-click cursor control [5, 6, 7, 8, 9, 10, 11, 12, 13], use of a robotic arm [14, 15, 16, 17, 18], and the voluntary control of paralyzed muscles [19, 20, 21].”
BackgroundCortical control of a prosthetic arm for self-feeding
Velliste, M., Perel, S., Spalding, M. C., Whitford, A. S., & Schwartz, A. B. (2008) · Nature · doi:10.1038/nature06996 · Cited by 1,591
Control of a two-dimensional movement signal by a noninvasive brain-computer interface in humans
Wolpaw, J. R., & McFarland, D. J. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0403504101 · Cited by 1,512
The sensations produced by electrical stimulation of the visual cortex
Brindley, G. S., & Lewin, W. S. (1968) · The Journal of Physiology · doi:10.1113/jphysiol.1968.sp008519 · Cited by 1,170 · cited 1×
“Microstimulation in humans has been used to induce visual [50, 51], and tactile perceptions [52–54].”
MethodComplex Movements Evoked by Microstimulation of Precentral Cortex
Graziano, M. S. A., Taylor, C. S. R., & Moore, T. (2002) · Neuron · doi:10.1016/s0896-6273(02)00698-0 · Cited by 921
Cortical microstimulation influences perceptual judgements of motion direction
Salzman, C. D., Britten, K. H., & Newsome, W. T. (1990) · Nature · doi:10.1038/346174a0 · Cited by 881
Sensory substitution and the human-machine interface
Bach-y-Rita, P., & W. Kercel, S. (2003) · Trends in Cognitive Sciences · doi:10.1016/j.tics.2003.10.013 · Cited by 858
Chronic, multisite, multielectrode recordings in macaque monkeys
Nicolelis, M. A. L., Dimitrov, D., Carmena, J. M., Crist, R., Lehew, G., Kralik, J. D., & Wise, S. P. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1934665100 · Cited by 740 · cited 1×
“Cortically controlled brain-computer interfaces (BCIs) were first demonstrated over ten years ago in humans and monkeys [1, 2, 3, 4].”
BackgroundCognitive Control Signals for Neural Prosthetics
Musallam, S., Corneil, B. D., Greger, B., Scherberger, H., & Andersen, R. A. (2004) · Science · doi:10.1126/science.1097938 · Cited by 663 · cited 1×
“BCI control has been demonstrated in sophisticated behaviors such as point-and-click cursor control [5, 6, 7, 8, 9, 10, 11, 12, 13], use of a robotic arm [14, 15, 16, 17, 18], and the voluntary control of paralyzed muscles [19, 20, 21].”
BackgroundControl of limb dynamics in normal subjects and patients without proprioception
Sainburg, R. L., Ghilardi, M. F., Poizner, H., & Ghez, C. (1995) · Journal of Neurophysiology · doi:10.1152/jn.1995.73.2.820 · Cited by 662 · cited 1×
“Their movements are slow and inaccurate, requiring a great deal of concentration to perform [24, 25].”
BackgroundA P300-based brain–computer interface for people with amyotrophic lateral sclerosis
Nijboer, F., Sellers, E. W., Mellinger, J., Jordan, M. A., Matuz, T., Furdea, A., Halder, S., Mochty, U., Krusienski, D. J., Vaughan, T. M., et al. (2008) · Clinical Neurophysiology · doi:10.1016/j.clinph.2008.03.034 · Cited by 633
Active tactile exploration using a brain–machine–brain interface
O’Doherty, J. E., Lebedev, M. A., Ifft, P. J., Zhuang, K. Z., Shokur, S., Bleuler, H., & Nicolelis, M. A. L. (2011) · Nature · doi:10.1038/nature10489 · Cited by 629
A high-performance neural prosthesis enabled by control algorithm design
Gilja, V., Nuyujukian, P., Chestek, C. A., Cunningham, J. P., Yu, B. M., Fan, J. M., Churchland, M. M., Kaufman, M. T., Kao, J. C., Ryu, S. I., et al. (2012) · Nature Neuroscience · doi:10.1038/nn.3265 · Cited by 564
Axons, but not cell bodies, are activated by electrical stimulation in cortical gray matter
Nowak, L. G., & Bullier, J. (1998) · Experimental Brain Research · doi:10.1007/s002210050304 · Cited by 492 · cited 1×
“Microstimulation presumably affects directly neurons in a small volume near the electrode tip, and indirectly affects neurons synaptically connected to the direct neurons [71, 72].”
BackgroundRestoration of grasp following paralysis through brain-controlled stimulation of muscles
Ethier, C., Oby, E. R., Bauman, M. J., & Miller, L. E. (2012) · Nature · doi:10.1038/nature10987 · Cited by 485
Electrical stimulation of neural tissue to evoke behavioral responses
Tehovnik, E. J. (1996) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(95)00131-x · Cited by 478 · cited 1×
“Microstimulation serves to evoke sensory effects that mimic the functional contribution of the stimulated area [40, 34, 35, 41, 42, 43, 44, 45, 46, 47].”
BackgroundRestoring sensorimotor function through intracortical interfaces: progress and looming challenges
Bensmaia, S. J., & Miller, L. E. (2014) · Nature Reviews Neuroscience · doi:10.1038/nrn3724 · Cited by 368 · cited 5×
“Most current BCIs function solely under visual feedback.”
BackgroundInfluentialRestoring the sense of touch with a prosthetic hand through a brain interface
Tabot, G. A., Dammann, J. F., Berg, J. A., Tenore, F. V., Boback, J. L., Vogelstein, R. J., & Bensmaia, S. J. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1221113110 · Cited by 320 · cited 5×
“Most current BCIs function solely under visual feedback.”
BackgroundInfluentialNeural Mechanisms for Forming a Perceptual Decision
Salzman, C. D., & Newsome, W. T. (1994) · Science · doi:10.1126/science.8146653 · Cited by 301 · cited 1×
“Microstimulation serves to evoke sensory effects that mimic the functional contribution of the stimulated area [40, 34, 35, 41, 42, 43, 44, 45, 46, 47].”
Background“Braille” reading by a blind volunteer by visual cortex stimulation
DOBELLE, W. H., MLADEJOVSKY, M. G., EVANS, J. R., ROBERTS, T. S., & GIRVIN, J. P. (1976) · Nature · doi:10.1038/259111a0 · Cited by 253 · cited 1×
“Microstimulation in humans has been used to induce visual [50, 51], and tactile perceptions [52–54].”
MethodButovas, S., & Schwarz, C. (2003) · Journal of Neurophysiology · doi:10.1152/jn.00245.2003 · Cited by 246 · cited 1×
“Microstimulation presumably activates excitatory and inhibitory cell bodies, as well as fibers of passage with minimal discrimination [46, 71].”
BackgroundForster, B., Cavina-Pratesi, C., Aglioti, S. M., & Berlucchi, G. (2002) · Experimental Brain Research · doi:10.1007/s00221-002-1017-9 · Cited by 207 · cited 2×
“Numerous studies have shown that tactile stimuli can improve performance in a wide range of tasks [28, 29], including driving [30], stimulus detection reaction time paradigms [31, 32], and target indication in BCI paradigms [33].”
BackgroundResultWhat electrical microstimulation has revealed about the neural basis of cognition
Cohen, M. R., & Newsome, W. T. (2004) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2004.03.016 · Cited by 165 · cited 1×
“Microstimulation serves to evoke sensory effects that mimic the functional contribution of the stimulated area [40, 34, 35, 41, 42, 43, 44, 45, 46, 47].”
BackgroundBehavioral Demonstration of a Somatosensory Neuroprosthesis
Berg, J. A., Dammann, J. F., Tenore, F. V., Tabot, G. A., Boback, J. L., Manfredi, L. R., Peterson, M. L., Katyal, K. D., Johannes, M. S., Makhlin, A., et al. (2013) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2244616 · Cited by 119 · cited 1×
“Microstimulation in sensory cortical areas has a long and impressive history as a means of providing sensory information to the brain [36, 63, 64].”
BackgroundA meta-analysis of vibrotactile and visual information displays for improving task performance
Prewett, M. S., Elliott, L. R., Walvoord, A. G., & Coovert, M. D. (2012) · IEEE Transactions on Systems, Man, and Cybernetics, Part C (Applications and Reviews) · doi:10.1109/tsmcc.2010.2103057 · Cited by 99 · cited 1×
“Numerous studies have shown that tactile stimuli can improve performance in a wide range of tasks [30, 31], including driving [32], stimulus detection reaction time paradigms [33, 34] and target indication in BCI paradigms [35].”
BackgroundInterfacing the Somatosensory System to Restore Touch and Proprioception: Essential Considerations
Weber, D. J., Friesen, R., & Miller, L. E. (2012) · Journal of Motor Behavior · doi:10.1080/00222895.2012.735283 · Cited by 98 · cited 3×
“Microstimulation patterning might be designed to mimic the responses that are recorded during actual touch [26].”
BackgroundInfluential
Cited by
Restoring the Sense of Touch Using a Sensorimotor Demultiplexing Neural Interface
Ganzer, P. D., Colachis, S. C., Schwemmer, M. A., Friedenberg, D. A., Dunlap, C. F., Swiftney, C. E., Jacobowitz, A. F., Weber, D. J., Bockbrader, M. A., & Sharma, G. (2020) · Cell · doi:10.1016/j.cell.2020.03.054 · Cited by 156
Kim, S., Callier, T., Tabot, G. A., Gaunt, R. A., Tenore, F. V., & Bensmaia, S. J. (2015) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1509265112 · Cited by 125
Biological and bionic hands: natural neural coding and artificial perception
Bensmaia, S. J. (2015) · Philosophical Transactions of the Royal Society B Biological Sciences · doi:10.1098/rstb.2014.0209 · Cited by 67
Metadata
- Authors
- Godlove, J. M., Whaite, E. O., & Batista, A. P.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2014-07-16
- Volume
- 11
- Issue
- 4
- Pages
- 046025
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W1999189233
- Cited by
- 44
- References
- 31
- FWCI
- 1.19
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.