AIRBORNE SPREAD OF MEASLES IN A SUBURBAN ELEMENTARY SCHOOL
The DOI matches its Crossref record.
Abstract
A measles epidemic in a modern suburban elementary school in upstate New York in spring, 1974, is analyzed in terms of a model which provides a basis for apportioning the chance of infection from classmates sharing the same home room, from airborne organisms recirculated by the ventilating system, and from exposure in school buses. The epidemic was notable because of its explosive nature and its occurrence in a school where 97% of the children had been vaccinated. Many had been vaccinated at less than one year of age. The index case was a girl in second grade who produced 28 secondary cases in 14 different classrooms. Organisms recirculated by the ventilating system were strongly implicated. After two subsequent generations, 60 children had been infected, and the epidemic subsided. From estimates of major physical and biologic factors, it was possible to calculate that the index case produced approximately 93 units of airborne infection (quanta) per minute. The epidemic pattern suggested that the secondaries were less infectious by an order of magnitude. The exceptional infectiousness of the index case, inadequate immunization of many of the children, and the high percentage of air recirculated throughout the school, are believed to account for the extent and sharpness of the outbreak.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Superspreading and the effect of individual variation on disease emergence
Lloyd-Smith, J. O., Schreiber, S. J., Kopp, P. E., & Getz, W. M. (2005) · Nature · doi:10.1038/nature04153 · Cited by 2,514
Airborne transmission of respiratory viruses
Wang, C. C., Prather, K. A., Sznitman, J., Jimenez, J. L., Lakdawala, S. S., Tufekci, Z., & Marr, L. C. (2021) · Science · doi:10.1126/science.abd9149 · Cited by 1,543
Li, Y., Leung, G. M., Tang, J. W., Yang, X., Chao, C. Y. H., Lin, J. Z., Lu, J. W., Nielsen, P. V., Niu, J., Qian, H., et al. (2007) · Indoor Air · doi:10.1111/j.1600-0668.2006.00445.x · Cited by 1,055
Buonanno, G., Stabile, L., & Morawska, L. (2020) · Environment International · doi:10.1016/j.envint.2020.105794 · Cited by 780
Recognition of aerosol transmission of infectious agents: a commentary
Tellier, R., Li, Y., Cowling, B. J., & Tang, J. W. (2019) · BMC Infectious Diseases · doi:10.1186/s12879-019-3707-y · Cited by 746
Miller, S. L., Nazaroff, W. W., Jimenez, J. L., Boerstra, A., Buonanno, G., Dancer, S. J., Kurnitski, J., Marr, L. C., Morawska, L., & Noakes, C. (2021) · Indoor Air · doi:10.1111/ina.12751 · Cited by 734
Probable airborne transmission of SARS-CoV-2 in a poorly ventilated restaurant
Li, Y., Qian, H., Hang, J., Chen, X., Cheng, P., Ling, H., Wang, S., Liang, P., Li, J., Xiao, S., et al. (2021) · Building and Environment · doi:10.1016/j.buildenv.2021.107788 · Cited by 689
Tang, J. W., Li, Y., Eames, I., Chan, P. K. S., & Ridgway, G. L. (2006) · Journal of Hospital Infection · doi:10.1016/j.jhin.2006.05.022 · Cited by 667
The efficacy of social distance and ventilation effectiveness in preventing COVID-19 transmission
Sun, C., & Zhai, Z. (2020) · Sustainable Cities and Society · doi:10.1016/j.scs.2020.102390 · Cited by 636
Rudnick, S. N., & Milton, D. K. (2003) · Indoor Air · doi:10.1034/j.1600-0668.2003.00189.x · Cited by 624
Transmission routes of respiratory viruses among humans
Kutter, J. S., Spronken, M. I., Fraaij, P. L., Fouchier, R. A., & Herfst, S. (2018) · Current Opinion in Virology · doi:10.1016/j.coviro.2018.01.001 · Cited by 611
Architectural design influences the diversity and structure of the built environment microbiome
Kembel, S. W., Jones, E., Kline, J., Northcutt, D., Stenson, J., Womack, A. M., Bohannan, B. J. M., Brown, G. Z., & Green, J. L. (2012) · The ISME Journal · doi:10.1038/ismej.2011.211 · Cited by 527
Influenza Virus in Human Exhaled Breath: An Observational Study
Fabian, P., McDevitt, J. J., DeHaan, W. H., Fung, R. O. P., Cowling, B. J., Chan, K. H., Leung, G. M., & Milton, D. K. (2008) · PLoS ONE · doi:10.1371/journal.pone.0002691 · Cited by 496
“Rudnick and Milton [30] used data from the influenza outbreak aboard an aircraft reported by Moser et al [31] and the WellsRiley equation for non-steady-state conditions [32] to estimate a quantum generation rate of from 79 to 128 quanta per hour for a highly infectious influenza case.”
MethodA guideline to limit indoor airborne transmission of COVID-19
Bazant, M. Z., & Bush, J. W. M. (2021) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2018995118 · Cited by 477
Vuorinen, V., Aarnio, M., Alava, M., Alopaeus, V., Atanasova, N., Auvinen, M., Balasubramanian, N., Bordbar, H., Erästö, P., Grande, R., et al. (2020) · Safety Science · doi:10.1016/j.ssci.2020.104866 · Cited by 472
“The coupling between the particle production and the ventilation rate could be modelled using classical methods, such as the Wells-Riley approach (Riley et al., 1978).”
MethodBuonanno, G., Morawska, L., & Stabile, L. (2020) · Environment International · doi:10.1016/j.envint.2020.106112 · Cited by 449
Effects of ventilation on the indoor spread of COVID-19
Bhagat, R. K., Davies Wykes, M. S., Dalziel, S. B., & Linden, P. F. (2020) · Journal of Fluid Mechanics · doi:10.1017/jfm.2020.720 · Cited by 414
Association of the infection probability of COVID-19 with ventilation rates in confined spaces
Dai, H., & Zhao, B. (2020) · Building Simulation · doi:10.1007/s12273-020-0703-5 · Cited by 409
Sze To, G. N., & Chao, C. Y. H. (2010) · Indoor Air · doi:10.1111/j.1600-0668.2009.00621.x · Cited by 383
Inhaling to mitigate exhaled bioaerosols
Edwards, D. A., Man, J. C., Brand, P., Katstra, J. P., Sommerer, K., Stone, H. A., Nardell, E., & Scheuch, G. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0408159101 · Cited by 362
Exhaled CO 2 as a COVID-19 Infection Risk Proxy for Different Indoor Environments and Activities
Peng, Z., & Jimenez, J. L. (2021) · Environmental Science & Technology Letters · doi:10.1021/acs.estlett.1c00183 · Cited by 321
COVID-19 Transmission, Current Treatment, and Future Therapeutic Strategies
Salian, V. S., Wright, J. A., Vedell, P. T., Nair, S., Li, C., Kandimalla, M., Tang, X., Carmona Porquera, E. M., Kalari, K. R., & Kandimalla, K. K. (2021) · Molecular Pharmaceutics · doi:10.1021/acs.molpharmaceut.0c00608 · Cited by 315
Mendell, M. J., Eliseeva, E. A., Davies, M. M., Spears, M., Lobscheid, A., Fisk, W. J., & Apte, M. G. (2013) · Indoor Air · doi:10.1111/ina.12042 · Cited by 299
Airborne spread of expiratory droplet nuclei between the occupants of indoor environments: A review
Ai, Z. T., & Melikov, A. K. (2018) · Indoor Air · doi:10.1111/ina.12465 · Cited by 278
Azuma, K., Yanagi, U., Kagi, N., Kim, H., Ogata, M., & Hayashi, M. (2020) · Environmental Health and Preventive Medicine · doi:10.1186/s12199-020-00904-2 · Cited by 263
Awada, M., Becerik-Gerber, B., Hoque, S., O'Neill, Z., Pedrielli, G., Wen, J., & Wu, T. (2021) · Building and Environment · doi:10.1016/j.buildenv.2020.107480 · Cited by 262
Airborne Infection: Theoretical Limits of Protection Achievable by Building Ventilation
Nardell, E. A., Keegan, J., Cheney, S. A., & Etkind, S. C. (1991) · American Review of Respiratory Disease · doi:10.1164/ajrccm/144.2.302 · Cited by 261
Ventilation control for airborne transmission of human exhaled bio-aerosols in buildings
Qian, H., & Zheng, X. (2018) · Journal of Thoracic Disease · doi:10.21037/jtd.2018.01.24 · Cited by 249
“They studied different wards in eight hospitals ventilated in Lima and Peru, and found that natural ventilation could provide much larger ventilation rates than mechanical ventilation system did, which helped reduce the airborne contagion, especially with the high ceiling and large windows according to the calculation…”
BackgroundMethodInfluentialEffect of impact stress on microbial recovery on an agar surface
Stewart, S. L., Grinshpun, S. A., Willeke, K., Terzieva, S., Ulevicius, V, & Donnelly, J. (1995) · Applied and Environmental Microbiology · doi:10.1128/aem.61.4.1232-1239.1995 · Cited by 237
“Examples of infections which may result from the presence of microorganisms in the air are tuberculosis (54), measles (53), legionellosis (10), and histoplasmosis (3).”
BackgroundUsing a Mathematical Model to Evaluate the Efficacy of TB Control Measures
Gammaitoni, L., & Nucci, M. C. (1997) · Emerging Infectious Diseases · doi:10.3201/eid0303.970310 · Cited by 225
“The following assumptions (4,24,25) are taken into consideration: differences in susceptibility are neglected; the rate at which quanta of infection are added to the air by infectious persons is considered constant; the latent period of the disease is longer than the time scale of the model, and the number of infectiv…”
BackgroundThe Airborne Transmission of Infection in Hospital Buildings: Fact or Fiction?
Beggs, C. B. (2003) · Indoor and Built Environment · doi:10.1177/1420326x03012001002 · Cited by 220
Airborne transmission of disease in hospitals
Eames, I., Tang, J. W., Li, Y., & Wilson, P. (2009) · Journal of The Royal Society Interface · doi:10.1098/rsif.2009.0407.focus · Cited by 216
Peng, Z., Rojas, A. L. P., Kropff, E., Bahnfleth, W., Buonanno, G., Dancer, S. J., Kurnitski, J., Li, Y., Loomans, M. G. L. C., Marr, L. C., et al. (2022) · Environmental Science & Technology · doi:10.1021/acs.est.1c06531 · Cited by 214
Clearing the Air: The Theory and Application of Ultraviolet Air Disinfection
Riley, R. L., & Nardell, E. A. (1989) · American Review of Respiratory Disease · doi:10.1164/ajrccm/139.5.1286 · Cited by 204
Self-citationAzimi, P., & Stephens, B. (2013) · Building and Environment · doi:10.1016/j.buildenv.2013.08.025 · Cited by 202
“Measles w570e5600 per hour [20] reasonable to assume that many passengers would also have been infected by longer-range aerosol transport.”
Basu, S., Andrews, J. R., Poolman, E. M., Gandhi, N. R., Shah, N. S., Moll, A., Moodley, P., Galvani, A. P., & Friedland, G. H. (2007) · The Lancet · doi:10.1016/s0140-6736(07)61636-5 · Cited by 201
Park, S., Choi, Y., Song, D., & Kim, E. K. (2021) · Science of The Total Environment · doi:10.1016/j.scitotenv.2021.147764 · Cited by 199
“The Wells–Riley equation is as follows (Riley et al., 1978):”
InfluentialBrowne, A., St-Onge Ahmad, S., Beck, C. R., & Nguyen-Van-Tam, J. S. (2016) · Journal of Travel Medicine · doi:10.1093/jtm/tav002 · Cited by 194
“Furuya (2014) used a Wells-Riley model [31] to determine that the mean reproduction number for influenza on a commuter train was >2 and the risk of transmission increased linearly with journey duration [47].”
MethodThe transmission of Mycobacterium tuberculosis in high burden settings
Yates, T. A., Khan, P. Y., Knight, G. M., Taylor, J. G., McHugh, T. D., Lipman, M., White, R. G., Cohen, T., Cobelens, F. G., Wood, R., et al. (2016) · The Lancet Infectious Diseases · doi:10.1016/s1473-3099(15)00499-5 · Cited by 192
Gao, N. P., Niu, J. L., Perino, M., & Heiselberg, P. (2008) · Building and Environment · doi:10.1016/j.buildenv.2007.10.023 · Cited by 188
“Based on the knowledge of infection dose (the number of organisms required to cause infection), the risk of airborne infection and ventilation rate per person can be correlated by Wells–Riley equation [31]:”
MethodAirborne infectious disease and the suppression of pulmonary bioaerosols
Fiegel, J., Clarke, R., & Edwards, D. A. (2006) · Drug Discovery Today · doi:10.1016/s1359-6446(05)03687-1 · Cited by 184
“Clear examples of the potential threat of airborne transmission include the dramatic spread of measles in the pre-vaccination era and the high death rate caused by airborne anthrax [1, 2] .”
Spatial distribution of infection risk of SARS transmission in a hospital ward
Qian, H., Li, Y., Nielsen, P. V., & Huang, X. (2009) · Building and Environment · doi:10.1016/j.buildenv.2008.11.002 · Cited by 181
Patterns of Transmission in Measles Outbreaks in the United States, 1985–1986
Markowitz, L. E., Preblud, S. R., Orenstein, W. A., Rovira, E. Z., Adams, N. C., Hawkins, C. E., & Hinman, A. R. (1989) · New England Journal of Medicine · doi:10.1056/nejm198901123200202 · Cited by 178
Di Gilio, A., Palmisani, J., Pulimeno, M., Cerino, F., Cacace, M., Miani, A., & de Gennaro, G. (2021) · Environmental Research · doi:10.1016/j.envres.2021.111560 · Cited by 178
“In fact, on the basis of the Wells-Riley model (Riley et al., 1978) and in order to describe the spread of airborne pathogens such as tuberculosis, measles, influenza, H1N1, coronavirus (SARSCoV) (Noakes et al., 2006; Liao et al., 2005; Nicas et al., 2005; Beggs et al., 2003; Rudnick and Milton,…”
Natural ventilation for reducing airborne infection in hospitals
Qian, H., Li, Y., Seto, W. H., Ching, P., Ching, W. H., & Sun, H. Q. (2010) · Building and Environment · doi:10.1016/j.buildenv.2009.07.011 · Cited by 170
“The risk of infection with an exposure can be calculated from the classical Wells–Riley equation [15], which was developed for predicting the risk of airborne transmission diseases; see Eq.”
Breathing, speaking, coughing or sneezing: What drives transmission of SARS‐CoV‐2?
Stadnytskyi, V., Anfinrud, P., & Bax, A. (2021) · Journal of Internal Medicine · doi:10.1111/joim.13326 · Cited by 162
Detection of Airborne Rhinovirus and Its Relation to Outdoor Air Supply in Office Environments
Myatt, T. A., Johnston, S. L., Zuo, Z., Wand, M., Kebadze, T., Rudnick, S., & Milton, D. K. (2004) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200306-760oc · Cited by 161
Building-Associated Risk of Febrile Acute Respiratory Diseases in Army Trainees
Brundage, J. F. (1988) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1988.03720140028029 · Cited by 158
Wainwright, C. E., France, M. W., O'Rourke, P., Anuj, S., Kidd, T. J., Nissen, M. D., Sloots, T. P., Coulter, C., Ristovski, Z., Hargreaves, M., et al. (2009) · Thorax · doi:10.1136/thx.2008.112466 · Cited by 135
“[24] [25] [26] The majority of respiratory pathogens have been thought to be spread by large droplets that settle within an approximate 1 m range of an individual, providing a low risk of airborne infection.”
BackgroundOu, C., Hu, S., Luo, K., Yang, H., Hang, J., Cheng, P., Hai, Z., Xiao, S., Qian, H., Xiao, S., et al. (2022) · Building and Environment · doi:10.1016/j.buildenv.2021.108414 · Cited by 110
“According to the well-known Wells-Riley equation [13], the requirement for the minimum ventilation rate at an acceptable infection risk may be estimated if the quanta generation rate is known.”
Poor ventilation worsens short-range airborne transmission of respiratory infection
Li, Y., Cheng, P., & Jia, W. (2022) · Indoor Air · doi:10.1111/ina.12946 · Cited by 110
Indoor Aerosol Science Aspects of SARS-CoV-2 Transmission
Nazaroff, W. W. (2022) · Indoor Air · doi:10.1111/ina.12970 · Cited by 70
Lygizos, M., Shenoi, S. V., Brooks, R. P., Bhushan, A., Brust, J. C., Zelterman, D., Deng, Y., Northrup, V., Moll, A. P., & Friedland, G. H. (2013) · BMC Infectious Diseases · doi:10.1186/1471-2334-13-300 · Cited by 51
“Previous work in healthcare facilities, but not in household settings, has demonstrated that ventilation, usually measured in air changes per hour (ACH), improves with larger windows and that greater room volume reduces the risk from airborne transmission as estimated using the Wells-Riley model [22-27].”
MethodEdwards, N. J., Widrick, R., Wilmes, J., Breisch, B., Gerschefske, M., Sullivan, J., Potember, R., & Espinoza-Calvio, A. (2021) · Aerosol Science and Technology · doi:10.1080/02786826.2021.1966376 · Cited by 45
“Most of the common guidance for reducing airborne infectious disease transmission is based primarily on the factor R, residence of particles (Mittal, Meneveau, and Wu 2020; Sze To and Chao 2010; Riley, Murphy, and Riley 1978).”
Background
Metadata
- Authors
- RILEY, E. C., MURPHY, G., & RILEY, R. L.
- Venue
- American Journal of Epidemiology
- Publisher
- Oxford University Press (OUP)
- Published
- 1978-05
- Volume
- 107
- Issue
- 5
- Pages
- 421-432
- ISSN
- 0002-9262 (ISSN-L)
- 1476-6256
- OpenAlex
- W2277854703
- Cited by
- 932
- References
- 0
- FWCI
- 3.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.