Control of FES thumb force using slip information obtained from the cutaneous electroneurogram in quadriplegic man
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
A tetraplegic volunteer was implanted with percutaneous intramuscular electrodes in hand and forearm muscles. Furthermore, a sensory nerve cuff electrode was implanted on the volar digital nerve to the radial side of the index finger branching off the median nerve. In laboratory experiments a stimulation system was used to produce a lateral grasp (key grip) while the neural activity was recorded with the cuff electrode. The nerve signal contained information that could be used to detect the occurrence of slips and further to increase stimulation intensity to the thumb flexor/adductor muscles to stop the slip. Thereby the system provided a grasp that could catch an object if it started to slip due to, e.g., decreasing muscle force or changes in load forces tangential to the surface of the object. This method enabled an automatic adjustment of the stimulation intensity to the lowest possible level without loosing the grip and without any prior knowledge about the strength of the muscles and the weight and surface texture of the object.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Johansson, R. S., & Vallbo, A. B. (1979) · The Journal of Physiology · doi:10.1113/jphysiol.1979.sp012619 · Cited by 1,291
Johansson, R. S., & Westling, G. (1987) · Experimental Brain Research · doi:10.1007/bf00236210 · Cited by 865
Cutaneous whole nerve recordings used for correction of footdrop in hemiplegic man
Haugland, M. K., & Sinkjaer, T. (1995) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.481970 · Cited by 168
Self-citationSensory nerve recording for closed‐loop control to restore motor functions
Popovic, D. B., Stein, R. B., Jovanovic, K. L., Dai, R., Kostov, A., & Armstrong, W. W. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.247801 · Cited by 159
Upshaw, B., & Sinkjaer, T. (1998) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.681183 · Cited by 74
Research works printed but not linked: 39
- 10.1109/10.293216 · DOI · Paper page
- 10.1109/10.32102 · DOI · Paper page
- 10.1109/10.481986 · DOI · Paper page
- 10.1007/978-3-642-80211-9_40 · doi:10.1007/978-3-642-80211-9_40
- 10.1007/978-1-4612-2104-3_46 · DOI
- slot, 1997, effect of chronically implanted nerve cuff electrodes on the electrophysiological properties of human sensory nerves, Artificial Organs, 21
- lickel, 1998, Restoration of lateral hand grasp in a tetraplegic patient applying natural sensory feedback, 1
- riso, 1995, characterization of cutaneous nerve responses for control of neuromotor prostheses, Proc 5th Vienna Int Workshop Functional Electrostimulation, 335
- 10.1007/BF02476115 · DOI
- howe, 1992, touch sensing for robotic manipulation and recognition, Robotics Review 2, 55
- 10.1007/BF00237997 · DOI · Paper page
- stein, 1992, optimal stimulation of paralyzed muscle after human spinal cord injury, Amer Physiologic Soc, 1393
- 10.1016/0014-4886(68)90041-1 · DOI · Paper page
- 10.1113/jphysiol.1973.sp010279 · DOI · Paper page
- 10.1113/jphysiol.1975.sp010835 · DOI · Paper page
- 10.1113/jphysiol.1979.sp012809 · DOI · Paper page
- vallbo, 1984, properties of cutaneous mechanoreceptors in the human hand related to touch sensation, Human Neurobiol, 3, 3
- 10.1007/BF00236209 · DOI · Paper page
- 10.1109/10.68206 · DOI
- stein, 1975, principles underlying new methods for chronic neural recording, Le Journal Canadien des Sciences Neurologiques, 235
- 10.1109/TBME.1987.325979 · DOI · Paper page
- 10.1109/TBME.1986.325808 · DOI · Paper page
- 10.1109/10.68205 · DOI
- 10.1111/j.1525-1594.1997.tb04661.x · DOI · Paper page
- 10.1002/eej.4390960517 · doi:10.1002/eej.4390960517
- webster, 1992, artificial sensors suitable for closed-loop control of fns, Neural Prostheses Replacing Motor Function After Disease or Disability, 88
- nathan, 1993, control strategies in fns systems for the upper extremities, Crit Rev Biomed Eng, 21, 485
- 10.1109/IEMBS.1993.979133 · DOI
- 10.1109/10.32108 · DOI · Paper page
- 10.1007/BF00242914 · DOI
- 10.1109/86.296344 · DOI · Paper page
- 10.1109/86.296345 · DOI · Paper page
- 10.1016/0165-0270(81)90033-9 · DOI
- 10.1109/10.32109 · DOI · Paper page
- edgar, 1996, a multiple sensor recording pacemaker for diagnosis and research, IEE Colloquium on Cardiac Pacing and Electrical Stimulation of the Heart (Ref No 1996/169), 6/1
- 10.1109/86.331566 · DOI
- 10.1016/0006-8993(91)91126-L · DOI
- 10.1016/0006-8993(66)90056-4 · DOI · Paper page
- 10.1385/0-89603-185-3:65 · DOI · Paper page
Cited by
Implanted Neural Interfaces: Biochallenges and Engineered Solutions
Grill, W. M., Norman, S. E., & Bellamkonda, R. V. (2009) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-061008-124927 · Cited by 488
“Nerve cuff electrodes are well developed for recording from peripheral nerves in animals (19, 23) and have been applied in humans to detect heel-strike for closed-loop control of electrical stimulation to treat foot drop (43) and to detect the onset of an object slipping from grasp for closed-loop control of electrica…”
BackgroundSelective Stimulation of Cat Sciatic Nerve Using an Array of Varying-Length Microelectrodes
Branner, A., Stein, R. B., & Normann, R. A. (2001) · Journal of Neurophysiology · doi:10.1152/jn.2001.85.4.1585 · Cited by 359
Badia, J., Boretius, T., Andreu, D., Azevedo-Coste, C., Stieglitz, T., & Navarro, X. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/3/036023 · Cited by 227
Ortiz-Catalan, M., Brånemark, R., Håkansson, B., & Delbeke, J. (2012) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-11-33 · Cited by 144
“Closed-loop control using different NBEs has been reported in animal models [115] and human patients [40,62].”
BackgroundMethodRaspopovic, S., Carpaneto, J., Udina, E., Navarro, X., & Micera, S. (2010) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-7-17 · Cited by 81
Design of a low-noise preamplifier for nerve cuff electrode recording
Rieger, R., Taylor, J., Demosthenous, A., Donaldson, N., & Langlois, P. J. (2003) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2003.814437 · Cited by 78
Micera, S., Jensen, W., Sepulveda, F., Riso, R. R., & Sinkjaer, T. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.930903 · Cited by 58
Very Low-Noise ENG Amplifier System Using CMOS Technology
Rieger, R., Schuettler, M., Pal, D., Clarke, C., Langlois, P., Taylor, J., & Donaldson, N. (2006) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2006.886731 · Cited by 57
Long‐term biocompatibility of implanted polymer‐based intrafascicular electrodes
Lawrence, S. M., Larsen, J. O., Horch, K. W., Riso, R., & Sinkjær, T. (2002) · Journal of Biomedical Materials Research · doi:10.1002/jbm.10303 · Cited by 55
Self-citationElAnsary, M., Xu, J., Filho, J. S., Dutta, G., Long, L., Tejeiro, C., Shoukry, A., Tang, C., Kilinc, E., Joshi, J., et al. (2021) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2021.3113354 · Cited by 48
Cavallaro, E., Micera, S., Dario, P., Jensen, W., & Sinkjaer, T. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.816075 · Cited by 44
Self-citationInmann, A., & Haugland, M. (2004) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2004.03.003 · Cited by 40
Self-citation
Metadata
- Authors
- Haugland, M., Lickel, A., Haase, J., & Sinkjaer, T.
- Venue
- IEEE Transactions on Rehabilitation Engineering
- Published
- 1999-06
- Volume
- 7
- Issue
- 2
- Pages
- 215-227
- ISSN
- 1063-6528 (ISSN-L)
- OpenAlex
- W2130603866
- Cited by
- 112
- References
- 5
- FWCI
- 9.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.