The DOI matches its Crossref record; 150 of the 150 references it cites were found in a registry or an index.
Brain-Computer Interfaces Using Electrocorticographic Signals
Abstract
Many studies over the past two decades have shown that people and animals can use brain signals to convey their intent to a computer using brain-computer interfaces (BCIs). BCI systems measure specific features of brain activity and translate them into control signals that drive an output. The sensor modalities that have most commonly been used in BCI studies have been electroencephalographic (EEG) recordings from the scalp and single-neuron recordings from within the cortex. Over the past decade, an increasing number of studies has explored the use of electrocorticographic (ECoG) activity recorded directly from the surface of the brain. ECoG has attracted substantial and increasing interest, because it has been shown to reflect specific details of actual and imagined actions, and because its technical characteristics should readily support robust and chronic implementations of BCI systems in humans. This review provides general perspectives on the ECoG platform; describes the different electrophysiological features that can be detected in ECoG; elaborates on the signal acquisition issues, protocols, and online performance of ECoG-based BCI studies to date; presents important limitations of current ECoG studies; discusses opportunities for further research; and finally presents a vision for eventual clinical implementation. In summary, the studies presented to date strongly encourage further research using the ECoG platform for basic neuroscientific research, as well as for translational neuroprosthetic applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927
Neuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295
Farwell, L. A., & Donchin, E. (1988) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(88)90149-6 · Cited by 3,228
Neuronal Population Coding of Movement Direction
Georgopoulos, A. P., Schwartz, A. B., & Kettner, R. E. (1986) · Science · doi:10.1126/science.3749885 · Cited by 3,161
BCI2000: A General-Purpose Brain-Computer Interface (BCI) System
Schalk, G., McFarland, D. J., Hinterberger, T., Birbaumer, N., & Wolpaw, J. R. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.827072 · Cited by 3,024
Self-citationHigh Gamma Power Is Phase-Locked to Theta Oscillations in Human Neocortex
Canolty, R. T., Edwards, E., Dalal, S. S., Soltani, M., Nagarajan, S. S., Kirsch, H. E., Berger, M. S., Barbaro, N. M., & Knight, R. T. (2006) · Science · doi:10.1126/science.1128115 · Cited by 2,650
The functional role of cross-frequency coupling
Canolty, R. T., & Knight, R. T. (2010) · Trends in Cognitive Sciences · doi:10.1016/j.tics.2010.09.001 · Cited by 2,101
Electroencephalography: Basic Principles, Clinical Applications and Related Fields
Torres, F. (1983) · Archives of Neurology · doi:10.1001/archneur.1983.04050030085025 · Cited by 1,812
Dissolvable films of silk fibroin for ultrathin conformal bio-integrated electronics
Kim, D.-H., Viventi, J., Amsden, J. J., Xiao, J., Vigeland, L., Kim, Y.-S., Blanco, J. A., Panilaitis, B., Frechette, E. S., Contreras, D., et al. (2010) · Nature Materials · doi:10.1038/nmat2745 · Cited by 1,721
Cortical control of a prosthetic arm for self-feeding
Velliste, M., Perel, S., Spalding, M. C., Whitford, A. S., & Schwartz, A. B. (2008) · Nature · doi:10.1038/nature06996 · Cited by 1,591
A spelling device for the paralysed
Birbaumer, N., Ghanayim, N., Hinterberger, T., Iversen, I., Kotchoubey, B., Kübler, A., Perelmouter, J., Taub, E., & Flor, H. (1999) · Nature · doi:10.1038/18581 · Cited by 1,577
Direct Cortical Control of 3D Neuroprosthetic Devices
Taylor, D. M., Tillery, S. I. H., & Schwartz, A. B. (2002) · Science · doi:10.1126/science.1070291 · Cited by 1,540
Control of a two-dimensional movement signal by a noninvasive brain-computer interface in humans
Wolpaw, J. R., & McFarland, D. J. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0403504101 · Cited by 1,512
Instant neural control of a movement signal
Serruya, M. D., Hatsopoulos, N. G., Paninski, L., Fellows, M. R., & Donoghue, J. P. (2002) · Nature · doi:10.1038/416141a · Cited by 1,409
A brain–computer interface using electrocorticographic signals in humans
Leuthardt, E. C., Schalk, G., Wolpaw, J. R., Ojemann, J. G., & Moran, D. W. (2004) · Journal of Neural Engineering · doi:10.1088/1741-2560/1/2/001 · Cited by 1,188
Self-citationAn EEG-based brain-computer interface for cursor control
Wolpaw, J. R., McFarland, D. J., Neat, G. W., & Forneris, C. A. (1991) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(91)90040-b · Cited by 1,114
Crone, N. (1998) · Brain · doi:10.1093/brain/121.12.2301 · Cited by 1,044
The Temporal Structures and Functional Significance of Scale-free Brain Activity
He, B. J., Zempel, J. M., Snyder, A. Z., & Raichle, M. E. (2010) · Neuron · doi:10.1016/j.neuron.2010.04.020 · Cited by 990
Manning, J. R., Jacobs, J., Fried, I., & Kahana, M. J. (2009) · The Journal of Neuroscience · doi:10.1523/jneurosci.2041-09.2009 · Cited by 973
Hemodynamic Signals Correlate Tightly with Synchronized Gamma Oscillations
Niessing, J., Ebisch, B., Schmidt, K. E., Niessing, M., Singer, W., & Galuske, R. A. W. (2005) · Science · doi:10.1126/science.1110948 · Cited by 806
A comparison of classification techniques for the P300 Speller
Krusienski, D. J., Sellers, E. W., Cabestaing, F., Bayoudh, S., McFarland, D. J., Vaughan, T. M., & Wolpaw, J. R. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/4/007 · Cited by 762
Power-Law Scaling in the Brain Surface Electric Potential
Miller, K. J., Sorensen, L. B., Ojemann, J. G., & den Nijs, M. (2009) · PLoS Computational Biology · doi:10.1371/journal.pcbi.1000609 · Cited by 742
Noninvasive Brain-Actuated Control of a Mobile Robot by Human EEG
del R. Millan, J., Renkens, F., Mourino, J., & Gerstner, W. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.827086 · Cited by 740
Spectral Changes in Cortical Surface Potentials during Motor Movement
Miller, K. J., Leuthardt, E. C., Schalk, G., Rao, R. P. N., Anderson, N. R., Moran, D. W., Miller, J. W., & Ojemann, J. G. (2007) · The Journal of Neuroscience · doi:10.1523/jneurosci.3886-06.2007 · Cited by 738
Self-citationRay, S., Crone, N. E., Niebur, E., Franaszczuk, P. J., & Hsiao, S. S. (2008) · The Journal of Neuroscience · doi:10.1523/jneurosci.2848-08.2008 · Cited by 722
A high-performance brain–computer interface
Santhanam, G., Ryu, S. I., Yu, B. M., Afshar, A., & Shenoy, K. V. (2006) · Nature · doi:10.1038/nature04968 · Cited by 698
Staba, R. J., Wilson, C. L., Bragin, A., Fried, I., & Engel, J. (2002) · Journal of Neurophysiology · doi:10.1152/jn.2002.88.4.1743 · Cited by 666
How many people are able to control a P300-based brain-computer interface (BCI)?
Guger, C., Daban, S., Sellers, E., Holzner, C., Krausz, G., Carabalona, R., Gramatica, F., & Edlinger, G. (2009) · Neuroscience Letters · doi:10.1016/j.neulet.2009.06.045 · Cited by 652
Flexible polyimide-based intracortical electrode arrays with bioactive capability
Rousche, P. J., Pellinen, D. S., Pivin, D. P., Williams, J. C., Vetter, R. J., & Kipke, D. R. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.914800 · Cited by 644
A P300-based brain–computer interface for people with amyotrophic lateral sclerosis
Nijboer, F., Sellers, E. W., Mellinger, J., Jordan, M. A., Matuz, T., Furdea, A., Halder, S., Mochty, U., Krusienski, D. J., Vaughan, T. M., et al. (2008) · Clinical Neurophysiology · doi:10.1016/j.clinph.2008.03.034 · Cited by 633
Cortical activity during motor execution, motor imagery, and imagery-based online feedback
Miller, K. J., Schalk, G., Fetz, E. E., den Nijs, M., Ojemann, J. G., & Rao, R. P. N. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0913697107 · Cited by 622
Self-citationPatients with ALS can use sensorimotor rhythms to operate a brain-computer interface
Kübler, A., Nijboer, F., Mellinger, J., Vaughan, T. M., Pawelzik, H., Schalk, G., McFarland, D. J., Birbaumer, N., & Wolpaw, J. R. (2005) · Neurology · doi:10.1212/01.wnl.0000158616.43002.6d · Cited by 539
Self-citationDecoding two-dimensional movement trajectories using electrocorticographic signals in humans
Schalk, G., Kubánek, J., Miller, K. J., Anderson, N. R., Leuthardt, E. C., Ojemann, J. G., Limbrick, D., Moran, D., Gerhardt, L. A., & Wolpaw, J. R. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/3/012 · Cited by 527
Self-citationBrain-Computer Interface—a new communication device for handicapped persons
Pfurtscheller, G., Flotzinger, D., & Kalcher, J. (1993) · Journal of Microcomputer Applications · doi:10.1006/jmca.1993.1030 · Cited by 502
Simeral, J. D., Kim, S.-P., Black, M. J., Donoghue, J. P., & Hochberg, L. R. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/2/025027 · Cited by 496
Two-dimensional movement control using electrocorticographic signals in humans
Schalk, G., Miller, K. J., Anderson, N. R., Wilson, J. A., Smyth, M. D., Ojemann, J. G., Moran, D. W., Wolpaw, J. R., & Leuthardt, E. C. (2008) · Journal of Neural Engineering · doi:10.1088/1741-2560/5/1/008 · Cited by 482
Self-citationBrain oscillations control hand orthosis in a tetraplegic
Pfurtscheller, G., Guger, C., Müller, G., Krausz, G., & Neuper, C. (2000) · Neuroscience Letters · doi:10.1016/s0304-3940(00)01471-3 · Cited by 472
Electroencephalographic (EEG) control of three-dimensional movement
McFarland, D. J., Sarnacki, W. A., & Wolpaw, J. R. (2010) · Journal of Neural Engineering · doi:10.1088/1741-2560/7/3/036007 · Cited by 454
Multichannel EEG-based brain-computer communication
Wolpaw, J. R., & McFarland, D. J. (1994) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(94)90135-x · Cited by 449
Pfurtscheller, G., Graimann, B., Huggins, J. E., Levine, S. P., & Schuh, L. A. (2003) · Clinical Neurophysiology · doi:10.1016/s1388-2457(03)00067-1 · Cited by 448
Changes in Spatial Patterns of Rabbit Olfactory EEG with Conditioning to Odors
Freeman, W. J., & Schneider, W. (1982) · Psychophysiology · doi:10.1111/j.1469-8986.1982.tb02598.x · Cited by 439
The brain response interface: communication through visually-induced electrical brain responses
Sutter, E. E. (1992) · Journal of Microcomputer Applications · doi:10.1016/0745-7138(92)90045-7 · Cited by 417
Signal quality of simultaneously recorded invasive and non-invasive EEG
Ball, T., Kern, M., Mutschler, I., Aertsen, A., & Schulze-Bonhage, A. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.02.028 · Cited by 403
An improved P300-based brain-computer interface
Serby, H., Yom-Tov, E., & Inbar, G. F. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2004.841878 · Cited by 403
A brain-computer interface for long-term independent home use
Sellers, E. W., Vaughan, T. M., & Wolpaw, J. R. (2010) · Amyotrophic Lateral Sclerosis · doi:10.3109/17482961003777470 · Cited by 400
Complex impedance spectroscopy for monitoring tissue responses to inserted neural implants
Williams, J. C., Hippensteel, J. A., Dilgen, J., Shain, W., & Kipke, D. R. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/4/007 · Cited by 399
A MEMS-based flexible multichannel ECoG-electrode array
Rubehn, B., Bosman, C., Oostenveld, R., Fries, P., & Stieglitz, T. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/3/036003 · Cited by 387
Spatial spectra of scalp EEG and EMG from awake humans
Freeman, W. J., Holmes, M. D., Burke, B. C., & Vanhatalo, S. (2003) · Clinical Neurophysiology · doi:10.1016/s1388-2457(03)00045-2 · Cited by 370
Miller, K. J., Zanos, S., Fetz, E. E., den Nijs, M., & Ojemann, J. G. (2009) · The Journal of Neuroscience · doi:10.1523/jneurosci.5506-08.2009 · Cited by 350
Long-term asynchronous decoding of arm motion using electrocorticographic signals in monkey
Chao (2010) · Frontiers in Neuroengineering · doi:10.3389/fneng.2010.00003 · Cited by 341
The wadsworth BCI research and development program: at home with BCI
Vaughan, T. M., McFarland, D. J., Schalk, G., Sarnacki, W. A., Krusienski, D. J., Sellers, E. W., & Wolpaw, J. R. (2006) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2006.875577 · Cited by 334
Self-citationSelecting the signals for a brain–machine interface
Andersen, R. A., Musallam, S., & Pesaran, B. (2004) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2004.10.005 · Cited by 332
Prediction of arm movement trajectories from ECoG-recordings in humans
Pistohl, T., Ball, T., Schulze-Bonhage, A., Aertsen, A., & Mehring, C. (2008) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2007.10.001 · Cited by 331
Lachaux, J., Fonlupt, P., Kahane, P., Minotti, L., Hoffmann, D., Bertrand, O., & Baciu, M. (2007) · Human Brain Mapping · doi:10.1002/hbm.20352 · Cited by 329
Towards an independent brain–computer interface using steady state visual evoked potentials
Allison, B. Z., McFarland, D. J., Schalk, G., Zheng, S. D., Jackson, M. M., & Wolpaw, J. R. (2008) · Clinical Neurophysiology · doi:10.1016/j.clinph.2007.09.121 · Cited by 327
Self-citationSpatial spectral analysis of human electrocorticograms including the alpha and gamma bands
Freeman, W. J., Rogers, L. J., Holmes, M. D., & Silbergeld, D. L. (2000) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(99)00160-0 · Cited by 323
Spatial properties of an EEG event in the olfactory bulb and cortex
Freeman, W. J. (1978) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(78)90126-8 · Cited by 309
Electrocorticographic gamma activity during word production in spoken and sign language
Crone, N. E., Hao, L., Hart, J., Boatman, D., Lesser, R. P., Irizarry, R., & Gordon, B. (2001) · Neurology · doi:10.1212/wnl.57.11.2045 · Cited by 299
(2006) · Human Kinetics eBooks · doi:10.5040/9781492596851 · Cited by 297
Kübler, A., Kotchoubey, B., Hinterberger, T., Ghanayim, N., Perelmouter, J., Schauer, M., Fritsch, C., Taub, E., & Birbaumer, N. (1999) · Experimental Brain Research · doi:10.1007/s002210050617 · Cited by 297
Lebedev, M. A., Carmena, J. M., O'Doherty, J. E., Zacksenhouse, M., Henriquez, C. S., Principe, J. C., & Nicolelis, M. A. L. (2005) · The Journal of Neuroscience · doi:10.1523/jneurosci.4088-04.2005 · Cited by 290
Decoding flexion of individual fingers using electrocorticographic signals in humans
Kubánek, J., Miller, K. J., Ojemann, J. G., Wolpaw, J. R., & Schalk, G. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/6/066001 · Cited by 285
Self-citationKasanetz, F., Riquelme, L. A., O'Donnell, P., & Murer, M. G. (2006) · The Journal of Physiology · doi:10.1113/jphysiol.2006.113050 · Cited by 281
Spatial patterns of visual cortical fast EEG during conditioned reflex in a rhesus monkey
Freeman, W. J., & van Dijk, B. W. (1987) · Brain Research · doi:10.1016/0006-8993(87)90933-4 · Cited by 280
Electrocorticographic high gamma activity versus electrical cortical stimulation mapping of naming
Sinai, A., Bowers, C. W., Crainiceanu, C. M., Boatman, D., Gordon, B., Lesser, R. P., Lenz, F. A., & Crone, N. E. (2005) · Brain · doi:10.1093/brain/awh491 · Cited by 266
Decoding natural grasp types from human ECoG
Pistohl, T., Schulze-Bonhage, A., Aertsen, A., Mehring, C., & Ball, T. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.06.084 · Cited by 249
Electrocorticography-based brain computer Interface-the seattle experience
Leuthardt, E. C., Miller, K. J., Schalk, G., Rao, R. P. N., & Ojemann, J. G. (2006) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2006.875536 · Cited by 245
Self-citationPei, X., Barbour, D. L., Leuthardt, E. C., & Schalk, G. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/4/046028 · Cited by 237
Self-citationFrequency dependence of the transmission of the EEG from cortex to scalp
Pfurtscheller, G., & Cooper, R. (1975) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(75)90215-1 · Cited by 237
Decoding spoken words using local field potentials recorded from the cortical surface
Kellis, S., Miller, K., Thomson, K., Brown, R., House, P., & Greger, B. (2010) · Journal of Neural Engineering · doi:10.1088/1741-2560/7/5/056007 · Cited by 235
Shain, W., Spataro, L., Dilgen, J., Haverstick, K., Retterer, S., Isaacson, M., Saltzman, M., & Turner, J. N. (2003) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.814800 · Cited by 227
Spatiotemporal dynamics of word processing in the human brain
Canolty, R. T. (2007) · Frontiers in Neuroscience · doi:10.3389/neuro.01.1.1.014.2007 · Cited by 226
A Practical Guide to Brain–Computer Interfacing with BCI2000
Schalk, G., & Mellinger, J. (2010) · Springer eBooks · doi:10.1007/978-1-84996-092-2 · Cited by 216
Self-citationEEG Control of a Virtual Helicopter in 3-Dimensional Space Using Intelligent Control Strategies
Royer, A. S., Doud, A. J., Rose, M. L., & He, B. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2010.2077654 · Cited by 216
Spatiotemporal imaging of cortical activation during verb generation and picture naming
Edwards, E., Nagarajan, S. S., Dalal, S. S., Canolty, R. T., Kirsch, H. E., Barbaro, N. M., & Knight, R. T. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2009.12.035 · Cited by 216
Simultaneous EEG 10 Hz desynchronization and 40 Hz synchronization during finger movements
Pfurtscheller, G., & Neuper, C. (1992) · NeuroReport · doi:10.1097/00001756-199212000-00006 · Cited by 212
Real-time control of a prosthetic hand using human electrocorticography signals: Technical note
Yanagisawa, T., Hirata, M., Saitoh, Y., Goto, T., Kishima, H., Fukuma, R., Yokoi, H., Kamitani, Y., & Yoshimine, T. (2011) · Journal of Neurosurgery · doi:10.3171/2011.1.jns101421 · Cited by 208
Spatio-temporal correlations in human gamma band electrocorticograms
Menon, V., Freeman, W. J., Cutillo, B. A., Desmond, J. E., Ward, M. F., Bressler, S. L., Laxer, K. D., Barbaro, N., & Gevins, A. S. (1996) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(95)00206-5 · Cited by 205
Pei, X., Leuthardt, E. C., Gaona, C. M., Brunner, P., Wolpaw, J. R., & Schalk, G. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.10.029 · Cited by 204
Self-citationEmulation of computer mouse control with a noninvasive brain–computer interface
McFarland, D. J., Krusienski, D. J., Sarnacki, W. A., & Wolpaw, J. R. (2008) · Journal of Neural Engineering · doi:10.1088/1741-2560/5/2/001 · Cited by 202
Donoghue, J. P., Nurmikko, A., Black, M., & Hochberg, L. R. (2007) · The Journal of Physiology · doi:10.1113/jphysiol.2006.127209 · Cited by 197
A direct brain interface based on event-related potentials
Levine, S. P., Huggins, J. E., BeMent, S. L., Kushwaha, R. K., Schuh, L. A., Rohde, M. M., Passaro, E. A., Ross, D. A., Elisevich, K. V., & Smith, B. J. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.847809 · Cited by 197
Implant Size and Fixation Mode Strongly Influence Tissue Reactions in the CNS
Thelin, J., Jörntell, H., Psouni, E., Garwicz, M., Schouenborg, J., Danielsen, N., & Linsmeier, C. E. (2011) · PLoS ONE · doi:10.1371/journal.pone.0016267 · Cited by 191
Neural prosthetic control signals from plan activity
Shenoy, K. V., Meeker, D., Cao, S., Kureshi, S. A., Pesaran, B., Buneo, C. A., Batista, A. P., Mitra, P. P., Burdick, J. W., & Andersen, R. A. (2003) · NeuroReport · doi:10.1097/00001756-200303240-00013 · Cited by 191
An Adaptive P300-Based Online Brain–Computer Interface
Lenhardt, A., Kaper, M., & Ritter, H. J. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.912816 · Cited by 190
Neurophysiologic correlates of fMRI in human motor cortex
Hermes, D., Miller, K. J., Vansteensel, M. J., Aarnoutse, E. J., Leijten, F. S. S., & Ramsey, N. F. (2012) · Human Brain Mapping · doi:10.1002/hbm.21314 · Cited by 188
Increased gamma-range activity in human sensorimotor cortex during performance of visuomotor tasks
Aoki, F., Fetz, E. E., Shupe, L., Lettich, E., & Ojemann, G. A. (1999) · Clinical Neurophysiology · doi:10.1016/s1388-2457(98)00064-9 · Cited by 177
Conner, C. R., Ellmore, T. M., Pieters, T. A., DiSano, M. A., & Tandon, N. (2011) · The Journal of Neuroscience · doi:10.1523/jneurosci.1457-11.2011 · Cited by 177
Darvas, F., Scherer, R., Ojemann, J. G., Rao, R. P. N., Miller, K. J., & Sorensen, L. B. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.08.041 · Cited by 173
EEG Event-related Desynchronization (ERD) and Event-related Synchronization (ERS)
Pfurtscheller, G., & da Silva, F. L. (2005) · Cited by 164
ECoG factors underlying multimodal control of a brain-computer interface
Wilson, J. A., Felton, E. A., Garell, P. C., Schalk, G., & Williams, J. C. (2006) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2006.875570 · Cited by 163
Self-citationFelton, E. A., Wilson, J. A., Williams, J. C., & Garell, P. C. (2007) · Journal of neurosurgery · doi:10.3171/jns.2007.106.3.495 · Cited by 162
Using the electrocorticographic speech network to control a brain–computer interface in humans
Leuthardt, E. C., Gaona, C., Sharma, M., Szrama, N., Roland, J., Freudenberg, Z., Solis, J., Breshears, J., & Schalk, G. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/3/036004 · Cited by 161
Self-citationOptimal spacing of surface electrode arrays for brain–machine interface applications
Slutzky, M. W., Jordan, L. R., Krieg, T., Chen, M., Mogul, D. J., & Miller, L. E. (2010) · Journal of Neural Engineering · doi:10.1088/1741-2560/7/2/026004 · Cited by 161
Miranda, H., Gilja, V., Chestek, C. A., Shenoy, K. V., & Meng, T. H. (2010) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2010.2044573 · Cited by 161
Sellers, E. W., Kubler, A., & Donchin, E. (2006) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2006.875580 · Cited by 160
Real-time functional brain mapping using electrocorticography
Miller, K. J., den Nijs, M., Shenoy, P., Miller, J. W., Rao, R. P. N., & Ojemann, J. G. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.05.029 · Cited by 159
Electrocorticographic amplitude predicts finger positions during slow grasping motions of the hand
Acharya, S., Fifer, M. S., Benz, H. L., Crone, N. E., & Thakor, N. V. (2010) · Journal of Neural Engineering · doi:10.1088/1741-2560/7/4/046002 · Cited by 157
Broadband Spectral Change: Evidence for a Macroscale Correlate of Population Firing Rate?: Figure 1.
Miller, K. J. (2010) · Journal of Neuroscience · doi:10.1523/jneurosci.6401-09.2010 · Cited by 154
Rapid Communication with a “P300” Matrix Speller Using Electrocorticographic Signals (ECoG)
Brunner, P., Ritaccio, A. L., Emrich, J. F., Bischof, H., & Schalk, G. (2011) · Frontiers in Neuroscience · doi:10.3389/fnins.2011.00005 · Cited by 150
Self-citationBrunner, P., Ritaccio, A. L., Lynch, T. M., Emrich, J. F., Wilson, J. A., Williams, J. C., Aarnoutse, E. J., Ramsey, N. F., Leuthardt, E. C., Bischof, H., et al. (2009) · Epilepsy & Behavior · doi:10.1016/j.yebeh.2009.04.001 · Cited by 145
Self-citationA 5 $\mu$W/Channel Spectral Analysis IC for Chronic Bidirectional Brain–Machine Interfaces
Avestruz, A.-T., Santa, W. A., Carlson, D., Jensen, R. M., Stanslaski, S. R., Helfenstine, A., & Denison, T. (2008) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2008.2006460 · Cited by 142
Jacobs, J., & Kahana, M. J. (2009) · Journal of Neuroscience · doi:10.1523/jneurosci.2187-09.2009 · Cited by 138
Jokeit, H., & Makeig, S. (1994) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.91.14.6339 · Cited by 137
Evolution of brain-computer interfaces: going beyond classic motor physiology
Leuthardt, E. C., Schalk, G., Roland, J. L., Rouse, A. G., & Moran, D. W. (2009) · Neurosurgical FOCUS · doi:10.3171/2009.4.focus0979 · Cited by 136
Self-citationWang, W., Degenhart, A. D., Collinger, J. L., Vinjamuri, R. K., Sudre, G. P., Adelson, P. D., Holder, D. L., Leuthardt, E. C., Moran, D. W., Boninger, M. L., et al. (2009) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2009.5333704 · Cited by 128
Self-citationGaona, C. M., Sharma, M., Freudenburg, Z. V., Breshears, J. D., Bundy, D. T., Roland, J. L., Barbour, D. L., Schalk, G., & Leuthardt, E. C. (2011) · Journal of Neuroscience · doi:10.1523/jneurosci.4722-10.2011 · Cited by 114
Self-citationBrain–computer interfacing based on cognitive control
Vansteensel, M. J., Hermes, D., Aarnoutse, E. J., Bleichner, M. G., Schalk, G., van Rijen, P. C., Leijten, F. S. S., & Ramsey, N. F. (2010) · Annals of Neurology · doi:10.1002/ana.21985 · Cited by 113
Self-citationNeurotrophic electrode: Method of assembly and implantation into human motor speech cortex
Bartels, J., Andreasen, D., Ehirim, P., Mao, H., Seibert, S., Wright, E. J., & Kennedy, P. (2008) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2008.06.030 · Cited by 108
Toda, H., Suzuki, T., Sawahata, H., Majima, K., Kamitani, Y., & Hasegawa, I. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.08.003 · Cited by 108
An EEG-based method for graded cursor control
McFarland, D. J., Neat, G. W., Read, R. F., & Wolpaw, J. R. (1993) · Psychobiology · doi:10.3758/bf03327130 · Cited by 107
Toward noninvasive brain-computer interfaces
Müller, K. R., & Blankertz, B. (2006) · IEEE Signal Processing Magazine · doi:10.1109/msp.2006.1708426 · Cited by 104
Mehring, C., Nawrot, M. P., de Oliveira, S. C., Vaadia, E., Schulze‐Bonhage, A., Aertsen, A., & Ball, T. (2004) · Journal of Physiology-Paris · doi:10.1016/j.jphysparis.2005.09.016 · Cited by 102
Leuthardt, E. C., Miller, K. J., Anderson, N., Schalk, G., Dowling, J. L., Miller, J. W., Moran, D. W., & Ojemann, J. G. (2007) · Operative Neurosurgery · doi:10.1227/01.neu.0000255413.70807.6e · Cited by 101
Self-citationLanguage-Related Potentials Specific to Human Language Cortex
Fried, I., Ojemann, G. A., & Fetz, E. E. (1981) · Science · doi:10.1126/science.7209537 · Cited by 100
Extraction and localization of mesoscopic motor control signals for human ECoG neuroprosthetics
Sanchez, J. C., Gunduz, A., Carney, P. R., & Príncipe, J. C. (2007) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2007.04.019 · Cited by 100
Margalit, E., Weiland, J. D., Clatterbuck, R. E., Fujii, G. Y., Maia, M., Tameesh, M., Torres, G. F., D’Anna, S. A., Desai, S., Piyathaisere, D. V., et al. (2003) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(02)00345-x · Cited by 96
Loeb, G. E., Walker, A. E., Uematsu, S., & Konigsmark, B. W. (1977) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820110206 · Cited by 95
Leuthardt, E. C., Freudenberg, Z., Bundy, D. T., & Roland, J. L. (2009) · Neurosurgical FOCUS · doi:10.3171/2009.4.focus0980 · Cited by 92
Self-citationTissue response to potential neuroprosthetic materials implanted subdurally
Yuen, T. G. H., Agnew, W. F., & Bullara, L. A. (1987) · Biomaterials · doi:10.1016/0142-9612(87)90103-7 · Cited by 91
Robust, long-term control of an electrocorticographic brain-computer interface with fixed parameters
Blakely, T. M., Miller, K. J., Zanos, S. P., Rao, R. P. N., & Ojemann, J. G. (2009) · Neurosurgical FOCUS · doi:10.3171/2009.4.focus0977 · Cited by 86
Identification of Electrocorticogram Patterns as the Basis for a Direct Brain Interface
Levine, S. P., Huggins, J. E., BeMent, S. L., Kushwaha, R. K., Schuh, L. A., Passaro, E. A., Rohde, M. M., & Ross, D. A. (1999) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199909000-00005 · Cited by 86
Cortical Spatio-temporal Dynamics Underlying Phonological Target Detection in Humans
Chang, E. F., Edwards, E., Nagarajan, S. S., Fogelson, N., Dalal, S. S., Canolty, R. T., Kirsch, H. E., Barbaro, N. M., & Knight, R. T. (2010) · Journal of Cognitive Neuroscience · doi:10.1162/jocn.2010.21466 · Cited by 82
Can Electrocorticography (ECoG) Support Robust and Powerful Brain-Computer Interfaces?
Schalk, G. (2010) · Frontiers in Neuroengineering · doi:10.3389/fneng.2010.00009 · Cited by 81
Self-citationReal-time detection of event-related brain activity
Schalk, G., Leuthardt, E. C., Brunner, P., Ojemann, J. G., Gerhardt, L. A., & Wolpaw, J. R. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2008.07.037 · Cited by 79
Self-citationKellis, S., House, P. A., Thomson, K. E., Brown, R. B., & Greger, B. E. (2009) · Neurosurgical FOCUS · doi:10.3171/2009.4.focus0974 · Cited by 75
Miller, K. J., Hermes, D., Honey, C. J., Sharma, M., Rao, R. P. N., den Nijs, M., Fetz, E. E., B, T. J. S. A., Hebb, A. O., Ojemann, J. G., et al. (2010) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2010.00197 · Cited by 72
Self-citationOjemann, G. A., Fried, I., & Lettich, E. (1989) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(89)90095-3 · Cited by 69
Schürmann, M., Demıralp, T., Başar, E., & Başar‐Eroğlu, C. (2000) · Neuroscience Letters · doi:10.1016/s0304-3940(00)01456-7 · Cited by 64
Schalk, G. (2008) · Journal of Neural Engineering · doi:10.1088/1741-2560/5/1/p01 · Cited by 63
Self-citationToro, C., Cox, C. L., Friehs, G. M., Ojakangas, C. L., Maxwell, R. E., Gates, J. R., Gumnit, R. J., & Ebner, T. J. (1994) · Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section · doi:10.1016/0168-5597(94)90127-9 · Cited by 61
Detection of Event-Related Potentials for Development of a Direct Brain Interface
Huggins, J. E., Levine, S. P., BeMent, S. L., et al. (1999) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199909000-00006 · Cited by 55
Chapter 63 Development of neuromotor prostheses for humans
Donoghue, J. P., Nurmikko, A. V., Friehs, G. M., & Black, M. J. (2004) · Supplements to Clinical neurophysiology · doi:10.1016/s1567-424x(09)70399-x · Cited by 54
Detection of movement-related patterns in ongoing single-channel electrocorticogram
Graimann, B., Huggins, J. E., Schlögl, A., Levine, S. P., & Pfurtscheller, G. (2003) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.816863 · Cited by 53
Neural Correlates of Visual?Spatial Attention in Electrocorticographic Signals in Humans
Gunduz, A., Brunner, P., Daitch, A. L., Leuthardt, E. C., Ritaccio, A. L., Pesaran, B., & Schalk, G. (2011) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2011.00089 · Cited by 51
Self-citationControl of a Visual Keyboard Using an Electrocorticographic Brain–Computer Interface
Krusienski, D. J., & Shih, J. J. (2010) · Neurorehabilitation and neural repair · doi:10.1177/1545968310382425 · Cited by 49
Enhanced gamma (30–150 Hz) frequency in the human medial temporal lobe
Hirai, N., Uchida, S., Maehara, T., Okubo, Y., & Shimizu, H. (1999) · Neuroscience · doi:10.1016/s0306-4522(98)00513-2 · Cited by 46
Rouse, A. G., & Moran, D. W. (2009) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2009.5333180 · Cited by 46
Evaluation of Electrode Array Material for Neural Prostheses
Bullara, L. A., Agnew, W. F., Yuen, T. G. H., Jacques, S., & Pudenz, R. H. (1979) · Neurosurgery · doi:10.1227/00006123-197912000-00006 · Cited by 43
Voluntary brain regulation and communication with electrocorticogram signals
Hinterberger, T., Widman, G., Lal, T. N., Hill, J., Tangermann, M., Rosenstiel, W., Schölkopf, B., Elger, C. E., & Birbaumer, N. (2008) · Epilepsy & Behavior · doi:10.1016/j.yebeh.2008.03.014 · Cited by 42
Quality estimation of subdurally recorded, event-related potentials based on signal-to-noise ratio
Rohde, M. M., BeMent, S. L., Huggins, J. E., Levine, S. P., Kushwaha, R. K., & Schuh, L. A. (2002) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.972837 · Cited by 36
Krusienski, D. J., & Shih, J. J. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/2/025006 · Cited by 34
Breshears, J. D., Gaona, C. M., Roland, J. L., Sharma, M., Anderson, N., Bundy, D. T., Freudenburg, Z. V., Smyth, M. D., Zempel, J. M., Limbrick, D. D., et al. (2011) · PEDIATRICS · doi:10.1542/peds.2010-1519 · Cited by 29
Self-citationElectrocorticography of waves associated with eye movements in man during wakefulness
Fourment, A., Calvet, J., & Bancaud, J. (1976) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(76)90076-6 · Cited by 28
A Cortical Recording Platform Utilizing ¿ECoG Electrode Arrays
Kim, J., Wilson, J. A., & Williams, J. C. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4353551 · Cited by 25
Roland, J. L., Miller, K. J., Freudenburg, Z. V., Sharma, M., Smyth, M. D., Gaona, C. M., Breshears, J. D., Corbetta, M., & Leuthardt, E. C. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/4/046013 · Cited by 23
Self-citationElectrocortical activity in fetal sheep in the last seven days of gestation
Shinozuka, N., & Nathanielsz, P. W. (1998) · The Journal of Physiology · doi:10.1111/j.1469-7793.1998.273by.x · Cited by 14
Wireless integrated circuit for the acquisition of electrocorticogram signals
Anderson, G. S., & Harrison, R. R. (2010) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2010.5538020 · Cited by 8
Evaluation of micro-electrocorticographic electrodes for electrostimulation
Wilks, S. J., Koivuniemi, A. S., Thongpang, S., Williams, J. C., & Otto, K. J. (2009) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2009.5333178 · Cited by 6
Cited by
Promises and limitations of human intracranial electroencephalography
Parvizi, J., & Kastner, S. (2018) · Nature Neuroscience · doi:10.1038/s41593-018-0108-2 · Cited by 631
Quo vadis artificial intelligence?
Jiang, Y., Li, X., Luo, H., Yin, S., & Kaynak, O. (2022) · Discover Artificial Intelligence · doi:10.1007/s44163-022-00022-8 · Cited by 544
Bi, L., Feleke, A. >., & Guan, C. (2019) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2019.02.011 · Cited by 418
An Electrocorticographic Brain Interface in an Individual with Tetraplegia
Wang, W., Collinger, J. L., Degenhart, A. D., Tyler-Kabara, E. C., Schwartz, A. B., Moran, D. W., Weber, D. J., Wodlinger, B., Vinjamuri, R. K., Ashmore, R. C., et al. (2013) · PLoS ONE · doi:10.1371/journal.pone.0055344 · Cited by 402
Davis, T. S., Wark, H. A. C., Hutchinson, D. T., Warren, D. J., O’Neill, K., Scheinblum, T., Clark, G. A., Normann, R. A., & Greger, B. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/3/036001 · Cited by 314
Metadata
- Authors
- Schalk, G., & Leuthardt, E. C.
- Venue
- IEEE Reviews in Biomedical Engineering
- Published
- 2011
- Volume
- 4
- Pages
- 140-154
- ISSN
- 1937-3333 (ISSN-L)
- 1941-1189
- OpenAlex
- W2142501675
- Cited by
- 427
- References
- 150
- FWCI
- 7.69
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.