CoChat

A PDMS-Based Integrated Stretchable Microelectrode Array (isMEA) for Neural and Muscular Surface Interfacing

Liang Guo, Guvanasen, G. S., Xi Liu, Tuthill, C., Nichols, T. R., DeWeerth, S. P. · 2013 · IEEE Transactions on Biomedical Circuits and Systems
Cited by 139

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Abstract

Numerous applications in neuroscience research and neural prosthetics, such as electrocorticogram (ECoG) recording and retinal prosthesis, involve electrical interactions with soft excitable tissues using a surface recording and/or stimulation approach. These applications require an interface that is capable of setting up high-throughput communications between the electrical circuit and the excitable tissue and that can dynamically conform to the shape of the soft tissue. Being a compliant material with mechanical impedance close to that of soft tissues, polydimethylsiloxane (PDMS) offers excellent potential as a substrate material for such neural interfaces. This paper describes an integrated technology for fabrication of PDMS-based stretchable microelectrode arrays (MEAs). Specifically, as an integral part of the fabrication process, a stretchable MEA is directly fabricated with a rigid substrate, such as a thin printed circuit board (PCB), through an innovative bonding technology-via-bonding-for integrated packaging. This integrated strategy overcomes the conventional challenge of high-density packaging for this type of stretchable electronics. Combined with a high-density interconnect technology developed previously, this stretchable MEA technology facilitates a high-resolution, high-density integrated system solution for neural and muscular surface interfacing. In this paper, this PDMS-based integrated stretchable MEA (isMEA) technology is demonstrated by an example design that packages a stretchable MEA with a small PCB. The resulting isMEA is assessed for its biocompatibility, surface conformability, electrode impedance spectrum, and capability to record muscle fiber activity when applied epimysially.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tbcas.2012.2192932

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 42

  1. guo, 2009, PDMS-based conformable microelectrode arrays with selectable novel 3-D microelectrode geometries for surface stimulation and recording, Proc IEEE Engineering in Medicine and Biology Society Conf, 1623
  2. guo, 2010, A PDMS -based conical-well microelectrode array for surface stimulation of neural tissues, IEEE Trans Biomed Eng, 57, 2485, 10.1109/TBME.2010.2052617 · DOI
  3. 10.1002/smll.201001456 · DOI
  4. 10.1088/1741-2560/2/1/013 · DOI · Paper page
  5. 10.1109/ICSENS.2005.1597774 · DOI
  6. 10.1109/MMB.2002.1002269 · DOI · Paper page
  7. 10.1109/NER.2011.5910642 · doi:10.1109/ner.2011.5910642
  8. 10.1109/BIOCAS.2010.5709604 · DOI
  9. 10.1109/BIOCAS.2009.5372075 · DOI
  10. 10.1002/adma.201000515 · DOI · Paper page
  11. 10.1109/TBCAS.2007.893186 · DOI
  12. 10.1109/TBCAS.2010.2078508 · DOI
  13. 10.1007/s10544-007-9132-9 · DOI
  14. 10.1007/s10544-010-9505-3 · DOI
  15. 10.1088/1741-2560/5/1/008 · DOI · Paper page
  16. 10.1088/1741-2560/4/3/012 · DOI · Paper page
  17. 10.1523/JNEUROSCI.3879-08.2008 · DOI · Paper page
  18. 10.1016/B978-044452190-3.00027-6 · DOI
  19. 10.1088/0957-0233/18/5/R01 · DOI
  20. 10.1109/IEMBS.2004.1404166 · DOI
  21. 10.1109/IEMBS.2010.5627717 · DOI
  22. 10.3389/fneng.2011.00005 · DOI
  23. 10.1016/S0165-0270(96)02202-9 · DOI
  24. 10.1021/am1002537 · DOI
  25. navarro, 1998, Stimulation and recording from regenerated peripheral nerves through polyimide sieve electrodes, J Peripher Nerv Syst, 3, 91
  26. lapatki, 2004, A thin, flexible multielectrode grid for high-density surface EMG, J Appl Phys, 96, 327
  27. 10.1016/j.snb.2007.10.069 · DOI · Paper page
  28. 10.1109/JSEN.2008.2006261 · DOI · Paper page
  29. 10.1016/j.mee.2008.01.033 · DOI
  30. 10.1109/10.936367 · DOI · Paper page
  31. 10.1109/TBME.1975.324562 · DOI · Paper page
  32. 10.1109/TBCAS.2011.2162840 · DOI · Paper page
  33. 10.1038/2855 · DOI · Paper page
  34. 10.1007/BF02368134 · DOI · Paper page
  35. 10.1002/adma.200801984 · DOI · Paper page
  36. 10.1063/1.2201874 · DOI · Paper page
  37. 10.1109/JPROC.2005.851502 · DOI · Paper page
  38. 10.1063/1.123478 · DOI · Paper page
  39. 10.1063/1.3469919 · DOI
  40. timpano, 2005, Mechanical characterization of gold thin films for RF-MEMS, Proc Virginia Space Grant Consortium Student Research Conf
  41. lin, 2008, Viscoelastic characterization of soft micropillars for cellular mechanics study, Proc 12th Int Conf Miniaturized Systems for Chemistry and Life Sciences, 278
  42. 10.1016/j.physe.2004.06.032 · DOI · Paper page

Cited by

See all 139

Metadata

Authors
Guo, L., Guvanasen, G. S., Liu, X., Tuthill, C., Nichols, T. R., & DeWeerth, S. P.
Venue
IEEE Transactions on Biomedical Circuits and Systems
Published
2013-02
Volume
7
Issue
1
Pages
1-10
ISSN
  • 1932-4545 (ISSN-L)
  • 1940-9990
OpenAlex
W2027910517
Cited by
139
References
10
FWCI
5.97
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.