The DOI matches its Crossref record; 89 of the 89 references it cites were found in a registry or an index.
Review of tissue simulating phantoms for optical spectroscopy, imaging and dosimetry
Open accessAbstract
Optical spectroscopy, imaging, and therapy tissue phantoms must have the scattering and absorption properties that are characteristic of human tissues, and over the past few decades, many useful models have been created. In this work, an overview of their composition and properties is outlined, by separating matrix, scattering, and absorbing materials, and discussing the benefits and weaknesses in each category. Matrix materials typically are water, gelatin, agar, polyester or epoxy and polyurethane resin, room-temperature vulcanizing (RTV) silicone, or polyvinyl alcohol gels. The water and hydrogel materials provide a soft medium that is biologically and biochemically compatible with addition of organic molecules, and are optimal for scientific laboratory studies. Polyester, polyurethane, and silicone phantoms are essentially permanent matrix compositions that are suitable for routine calibration and testing of established systems. The most common three choices for scatters have been: (1.) lipid based emulsions, (2.) titanium or aluminum oxide powders, and (3.) polymer microspheres. The choice of absorbers varies widely from hemoglobin and cells for biological simulation, to molecular dyes and ink as less biological but more stable absorbers. This review is an attempt to indicate which sets of phantoms are optimal for specific applications, and provide links to studies that characterize main phantom material properties and recipes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Absorption and Scattering of Light by Small Particles
Bohren, C. F., & Huffman, D. R. (1998) · doi:10.1002/9783527618156 · Cited by 18,474
Optical Constants of Water in the 200-nm to 200-μm Wavelength Region
Hale, G. M., & Querry, M. R. (1973) · Applied Optics · doi:10.1364/ao.12.000555 · Cited by 4,468
A review of the optical properties of biological tissues
Cheong, W. F., Prahl, S. A., & Welch, A. J. (1990) · IEEE Journal of Quantum Electronics · doi:10.1109/3.64354 · Cited by 2,530
Estimation of optical pathlength through tissue from direct time of flight measurement
Delpy, D. T., Cope, M., Zee, P. V. D., Arridge, S., Wray, S., & Wyatt, J. (1988) · Physics in Medicine and Biology · doi:10.1088/0031-9155/33/12/008 · Cited by 2,245
Patterson, M. S., Chance, B., & Wilson, B. C. (1989) · Applied Optics · doi:10.1364/ao.28.002331 · Cited by 2,087
Self-citationElastic Moduli of Breast and Prostate Tissues under Compression
Krouskop, T. A., Wheeler, T. M., Kallel, F., Garra, B. S., & Hall, T. (1998) · Ultrasonic Imaging · doi:10.1177/016173469802000403 · Cited by 1,703
Optical-Thermal Response of Laser-Irradiated Tissue
(2011) · Springer eBooks · doi:10.1007/978-90-481-8831-4 · Cited by 1,424
Farrell, T. J., Patterson, M. S., & Wilson, B. (1992) · Medical Physics · doi:10.1118/1.596777 · Cited by 1,378
Self-citationOptical Coherence Tomography: An Emerging Technology for Biomedical Imaging and Optical Biopsy
Fujimoto, J. G., Pitris, C., Boppart, S. A., & Brezinski, M. E. (2000) · Neoplasia · doi:10.1038/sj.neo.7900071 · Cited by 1,138
Light scattering in lntralipid-10% in the wavelength range of 400–1100 nm
van Staveren, H. J., Moes, C. J. M., van Marie, J., Prahl, S. A., & van Gemert, M. J. C. (1991) · Applied Optics · doi:10.1364/ao.30.004507 · Cited by 1,106
Advances in In Vivo Bioluminescence Imaging of Gene Expression
Contag, C. H., & Bachmann, M. H. (2002) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.4.111901.093336 · Cited by 870
Fluorescence molecular tomography resolves protease activity in vivo
Ntziachristos, V., Tung, C.-H., Bremer, C., & Weissleder, R. (2002) · Nature Medicine · doi:10.1038/nm729 · Cited by 827
The multiplier method of Hestenes and Powell applied to convex programming
Rockafellar, R. T. (1973) · Journal of Optimization Theory and Applications · doi:10.1007/bf00934777 · Cited by 705
Arridge, S. R., Cope, M., & Delpy, D. T. (1992) · Physics in Medicine and Biology · doi:10.1088/0031-9155/37/7/005 · Cited by 595
Optical properties of intralipid: A phantom medium for light propagation studies
Flock, S. T., Jacques, S. L., Wilson, B. C., Star, W. M., & van Gemert, M. J. C. (1992) · Lasers in Surgery and Medicine · doi:10.1002/lsm.1900120510 · Cited by 578
Phantom materials for elastography
Hall, T. J., Bilgen, M., Insana, M. F., & Krouskop, T. A. (1997) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.656639 · Cited by 516
Kienle, A., Lilge, L., Patterson, M. S., Hibst, R., Steiner, R., & Wilson, B. C. (1996) · Applied Optics · doi:10.1364/ao.35.002304 · Cited by 495
Self-citationOptical reflectance and transmittance of tissues: principles and applications
Wilson, B. C., & Jacques, S. L. (1990) · IEEE Journal of Quantum Electronics · doi:10.1109/3.64355 · Cited by 421
Culver, J. P., Durduran, T., Furuya, D., Cheung, C., Greenberg, J. H., & Yodh, A. G. (2003) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/01.wcb.0000076703.71231.bb · Cited by 420
Troy, T., Jekic-McMullen, D., Sambucetti, L., & Rice, B. (2004) · Molecular Imaging · doi:10.1162/153535004773861688 · Cited by 418
Laser-Tissue Interactions: Photochemical, Photothermal, and Photomechanical
Jacques, S. L. (1992) · Surgical Clinics of North America · doi:10.1016/s0039-6109(16)45731-2 · Cited by 381
Yokoyama, F., Masada, I., Shimamura, K., Ikawa, T., & Monobe, K. (1986) · Colloid & Polymer Science · doi:10.1007/bf01412597 · Cited by 375
Imaging superficial tissues with polarized light
Jacques, S. L., Roman, J. R., & Lee, K. (2000) · Lasers in Surgery and Medicine · doi:10.1002/(sici)1096-9101(2000)26:2<119::aid-lsm3>3.0.co;2-y · Cited by 366
Hawrysz, D. J., & Sevick-Muraca, E. M. (2000) · Neoplasia · doi:10.1038/sj.neo.7900118 · Cited by 340
Fluorescence-enhanced, near infrared diagnostic imaging with contrast agents
Sevick-Muraca, E. M., Houston, J. P., & Gurfinkel, M. (2002) · Current Opinion in Chemical Biology · doi:10.1016/s1367-5931(02)00356-3 · Cited by 328
Oraevsky, A. A., Jacques, S. L., & Tittel, F. K. (1997) · Applied Optics · doi:10.1364/ao.36.000402 · Cited by 298
A solid tissue phantom for photon migration studies
Cubeddu, R., Pifferi, A., Taroni, P., Torricelli, A., & Valentini, G. (1997) · Physics in Medicine and Biology · doi:10.1088/0031-9155/42/10/011 · Cited by 289
Optical-based molecular imaging: contrast agents and potential medical applications
Bremer, C., Ntziachristos, V., & Weissleder, R. (2003) · European Radiology · doi:10.1007/s00330-002-1610-0 · Cited by 286
Srinivasan, S., Pogue, B. W., Jiang, S., Dehghani, H., Kogel, C., Soho, S., Gibson, J. J., Tosteson, T. D., Poplack, S. P., & Paulsen, K. D. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2032822100 · Cited by 267
Self-citationOptical image reconstruction using frequency-domain data: simulations and experiments
Jiang, H., Pogue, B. W., Patterson, M. S., Paulsen, K. D., & Osterberg, U. L. (1996) · Journal of the Optical Society of America A · doi:10.1364/josaa.13.000253 · Cited by 260
Self-citationModeling optical and thermal distributions in tissue during laser irradiation
Jacques, S. L., & Prahl, S. A. (1987) · Lasers in Surgery and Medicine · doi:10.1002/lsm.1900060604 · Cited by 259
It's not just about anatomy: In vivo bioluminescence imaging as an eyepiece into biology
Contag, C. H., & Ross, B. D. (2002) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10178 · Cited by 256
Patterson, M. S., & Pogue, B. W. (1994) · Applied Optics · doi:10.1364/ao.33.001963 · Cited by 248
Self-citationPerformance assessment of photon migration instruments: the MEDPHOT protocol
Pifferi, A., Torricelli, A., Bassi, A., Taroni, P., Cubeddu, R., Wabnitz, H., Grosenick, D., Möller, M., Macdonald, R., Swartling, J., et al. (2005) · Applied Optics · doi:10.1364/ao.44.002104 · Cited by 245
Determination of oxygen gradients in engineered tissue using a fluorescent sensor
Kellner, K., Liebsch, G., Klimant, I., Wolfbeis, O. S., Blunk, T., Schulz, M. B., & Göpferich, A. (2002) · Biotechnology and Bioengineering · doi:10.1002/bit.10352 · Cited by 238
Flock, S. T., Wilson, B. C., & Patterson, M. S. (1987) · Medical Physics · doi:10.1118/1.596010 · Cited by 212
Self-citationPoly(vinyl alcohol) gels for use as tissue phantoms in photoacoustic mammography
Kharine, A., Manohar, S., Seeton, R., Kolkman, R. G. M., Bolt, R. A., Steenbergen, W., & Mul, F. F. M. D. (2003) · Physics in Medicine and Biology · doi:10.1088/0031-9155/48/3/306 · Cited by 193
Measurements of scattering and absorption changes in muscle and brain
Gratton, E., Fantini, S., Franceschini, M. A., Gratton, G., & Fabiani, M. (1997) · Philosophical Transactions of the Royal Society of London. Series B: Biological Sciences · doi:10.1098/rstb.1997.0055 · Cited by 182
Firbank, M., Oda, M., & Delpy, D. T. (1995) · Physics in Medicine and Biology · doi:10.1088/0031-9155/40/5/016 · Cited by 181
Optical spectroscopy for detection of neoplasia
Sokolov, K., Follen, M. M., & Richards-Kortum, R. R. (2002) · Current Opinion in Chemical Biology · doi:10.1016/s1367-5931(02)00381-2 · Cited by 177
Ultrafast time-gated imaging in thick tissues: a step toward optical mammography
Das, B. B., Yoo, K. M., & Alfano, R. R. (1993) · Optics Letters · doi:10.1364/ol.18.001092 · Cited by 173
The use of India ink as an optical absorber in tissue-simulating phantoms
Madsen, S. J., Patterson, M. S., & Wilson, B. C. (1992) · Physics in Medicine and Biology · doi:10.1088/0031-9155/37/4/012 · Cited by 170
Self-citationAnisotropy of light propagation in human skin
Nickell, S., Hermann, M., Essenpreis, M., Farrell, T. J., Krämer, U., & Patterson, M. S. (2000) · Physics in Medicine and Biology · doi:10.1088/0031-9155/45/10/310 · Cited by 167
Self-citationMeasurement of cytochrome oxidase and mitochondrial energetics by near–infrared spectroscopy
Cooper, C. E., & Springett, R. (1997) · Philosophical Transactions of the Royal Society of London. Series B: Biological Sciences · doi:10.1098/rstb.1997.0048 · Cited by 160
Light dosimetry in optical phantoms and in tissues: I. Multiple flux and transport theory
Star, W., Marijnissen, J. P. A., & van Gemert, M. J. C. (1988) · Physics in Medicine and Biology · doi:10.1088/0031-9155/33/4/004 · Cited by 155
Time resolved propagation of ultrashort laser pulses within turbid tissues
Jacques, S. L. (1989) · Applied Optics · doi:10.1364/ao.28.002223 · Cited by 148
A design for a stable and reproducible phantom for use in near infra-red imaging and spectroscopy
Firbank, M., & Delpy, D. T. (1993) · Physics in Medicine and Biology · doi:10.1088/0031-9155/38/6/015 · Cited by 147
Cooper, C. E., Elwell, C. E., Meek, J. H., Matcher, S. J., Wyatt, J., Cope, M., & Delpy, D. T. (1996) · Pediatric Research · doi:10.1203/00006450-199601000-00005 · Cited by 147
Star, W. M. (1997) · Physics in Medicine and Biology · doi:10.1088/0031-9155/42/5/003 · Cited by 146
Deep subsurface imaging in tissues using spectral and polarization filtering
Demos, S. G., Radousky, H. B., & Alfano, R. R. (2000) · Optics Express · doi:10.1364/oe.7.000023 · Cited by 143
In Vivo Tomographic Imaging of Near-Infrared Fluorescent Probes
Ntziachristos, V., Bremer, C., Graves, E. E., Ripoll, J., & Weissleder, R. (2002) · Molecular Imaging · doi:10.1162/153535002320162732 · Cited by 141
Time-gated transillumination of biological tissues and tissuelike phantoms
Mitić, G., Kölzer, J., Otto, J., Plies, E., Sölkner, G., & Zinth, W. (1994) · Applied Optics · doi:10.1364/ao.33.006699 · Cited by 133
Clinical testing of a photoacoustic probe for port wine stain depth determination
Viator, J. A., Au, G., Paltauf, G., Jacques, S. L., Prahl, S. A., Ren, H., Chen, Z., & Nelson, J. S. (2002) · Lasers in Surgery and Medicine · doi:10.1002/lsm.10015 · Cited by 127
Wagnières, G., Cheng, S., Zellweger, M., Utke, N., Braichotte, D. R., Ballini, J., & van den Bergh, H. (1997) · Physics in Medicine and Biology · doi:10.1088/0031-9155/42/7/014 · Cited by 123
Shin, H., Temenoff, J. S., Bowden, G. C., Zygourakis, K., Farach‐Carson, M. C., Yaszemski, M. J., & Mikos, A. G. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2004.09.050 · Cited by 119
Vishwanath, K., Pogue, B. W., & Mycek, M. (2002) · Physics in Medicine and Biology · doi:10.1088/0031-9155/47/18/308 · Cited by 117
Self-citationRealistic three-dimensional epithelial tissue phantoms for biomedical optics
Sokolov, K., Galvan, J., Myakov, A. V., et al. (2002) · Journal of Biomedical Optics · doi:10.1117/1.1427052 · Cited by 106
Swartling, J., Dam, J. S., & Andersson‐Engels, S. (2003) · Applied Optics · doi:10.1364/ao.42.004612 · Cited by 104
Drezek, R. A., Richards-Kortum, R. R., BREWER, M. A., Feld, M. S., Pitris, C., Ferenczy, A. S., Faupel, M. L., & Follen, M. M. (2003) · Cancer · doi:10.1002/cncr.11678 · Cited by 100
Suzuki, K., Yamashita, Y., Ohta, K., Kaneko, M., Yoshida, M., & Chance, B. (1996) · Journal of Biomedical Optics · doi:10.1117/12.239902 · Cited by 99
Hull, E. L., Nichols, M. G., & Foster, T. H. (1998) · Physics in Medicine and Biology · doi:10.1088/0031-9155/43/11/014 · Cited by 99
Effects of the Menstrual Cycle on the Red and Near-infrared Optical Properties of the Human Breast ¶
Cubeddu, R., D’Andrea, C., Pifferi, A., et al. (2000) · Photochemistry and Photobiology · doi:10.1562/0031-8655(2000)0720383eotmco2.0.co2 · Cited by 97
Pifferi, A., Swartling, J., Chikoidze, E., Torricelli, A. M., Taroni, P., Bassi, A. L., Andersson‐Engels, S., & Cubeddu, R. (2004) · Journal of Biomedical Optics · doi:10.1117/1.1802171 · Cited by 96
Lualdi, M., Colombo, A., Farina, B., Tomatis, S., & Marchesini, R. (2001) · Lasers in Surgery and Medicine · doi:10.1002/lsm.1044 · Cited by 94
Wilson, B. C., Müller, P. J., & Yanch, J. C. (1986) · Physics in Medicine and Biology · doi:10.1088/0031-9155/31/2/002 · Cited by 87
Metabolic mapping with bioluminescence: basic and clinical relevance
Walenta, S., Schroeder, T., & Mueller‐Klieser, W. (2002) · Biomolecular Engineering · doi:10.1016/s1389-0344(01)00107-1 · Cited by 85
Heritabilities and paradigm shifts
Alatalo, R. V., Mappes, J., & Elgar, M. A. (1997) · Nature · doi:10.1038/385402a0 · Cited by 81
In Vivo NADH Fluorescence Monitoring as an Assay for Cellular Damage in Photodynamic Therapy¶
Pogue, B. W., Pitts, J. D., Mycek, M., Sloboda, R. D., Wilmot, C. M., Brandsema, J. F., & O’Hara, J. A. (2001) · Photochemistry and Photobiology · doi:10.1562/0031-8655(2001)0740817ivnfma2.0.co2 · Cited by 75
Self-citationIn vivo near-infrared spectral detection of pressure-induced changes in breast tissue
Jiang, S., Pogue, B. W., Paulsen, K. D., Kogel, C. A., & Poplack, S. P. (2003) · Optics Letters · doi:10.1364/ol.28.001212 · Cited by 74
Self-citationAdvances in optical imaging of the newborn infant brain
Hebden, J. C. (2003) · Psychophysiology · doi:10.1111/1469-8986.00052 · Cited by 72
Diaphanography in the diagnosis of breast cancer.
Drexler, B., Davis, J. L., & Schofield, G. (1985) · Radiology · doi:10.1148/radiology.157.1.4034975 · Cited by 70
Collier, T., Follen, M. M., Malpica, A. L., & Richards-Kortum, R. R. (2005) · Applied Optics · doi:10.1364/ao.44.002072 · Cited by 70
Nieman, L. T., Myakov, A. V., Aaron, J., & Sokolov, K. (2004) · Applied Optics · doi:10.1364/ao.43.001308 · Cited by 69
Durkin, A. J., Jaikumar, S., & Richards-Kortum, R. R. (1993) · Applied Spectroscopy · doi:10.1366/0003702934066244 · Cited by 65
Spectral priors improve near-infrared diffuse tomography more than spatial priors
Brooksby, B. A., Srinivasan, S., Jiang, S., Dehghani, H., Pogue, B. W., Paulsen, K. D., Weaver, J. B., Kogel, C. A., & Poplack, S. P. (2005) · Optics Letters · doi:10.1364/ol.30.001968 · Cited by 64
Self-citationThresholds for detecting and characterizing focal lesions using steady‐state MR elastography
Doyley, M. M., Weaver, J. B., Houten, E. E. W. V., Kennedy, F. E., & Paulsen, K. D. (2003) · Medical Physics · doi:10.1118/1.1556607 · Cited by 57
Pogue, B. W., Lilge, L. D., Patterson, M. S., Wilson, B. C., & Hasan, T. G. (1997) · Applied Optics · doi:10.1364/ao.36.007257 · Cited by 55
Self-citationA dynamic phantom brain model for near-infrared spectroscopy
Kurth, C. D., Liu, H., Thayer, W. S., & Chance, B. (1995) · Physics in Medicine and Biology · doi:10.1088/0031-9155/40/12/006 · Cited by 46
Doppler optical coherence tomography for measuring flow in engineered tissue
Mason, C., Markusen, J. F., Town, M. A., Dunnill, P., & Wang, R. K. (2004) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.03.035 · Cited by 46
Fenton, B. M., Rofstad, E. K., Degner, F. L., et al. (1988) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/80.20.1612 · Cited by 46
Near-infrared breast tomography calibration with optoelastic tissue simulating phantoms
Jiang, S., Pogue, B. W., McBride, T. O., Doyley, M. M., Poplack, S. P., & Paulsen, K. D. (2003) · Journal of Electronic Imaging · doi:10.1117/1.1587153 · Cited by 44
Self-citationKienle, A., Patterson, M. S., Ott, L., & Steiner, R. W. (1996) · Applied Optics · doi:10.1364/ao.35.003404 · Cited by 41
Self-citationLohwasser, R., & Soelkner, G. (1999) · Applied Optics · doi:10.1364/ao.38.002128 · Cited by 39
Design and Characterisation of a Tissue Phantom System for Optical Diagnostics
Beck, G. C., Akguen, N., Rück, A., & Steiner, R. W. (1998) · Lasers in Medical Science · doi:10.1007/s101030050070 · Cited by 36
Viehoever, A. R., Anderson, D., Jansen, D., & Mahadevan-Jansen, A. M. (2003) · Photochemistry and Photobiology · doi:10.1562/0031-8655(2003)0780517orcaae2.0.co2 · Cited by 32
Controlled temperature tissue fusion: Ho:YAG laser welding of rat intestine in vivo, Part Two
Çilesiz, I. F., Thomsen, S., Welch, A. J., & Chan, E. K. Y. (1997) · Lasers in Surgery and Medicine · doi:10.1002/(sici)1096-9101(1997)21:3<227::aid-lsm2>3.0.co;2-s · Cited by 30
Liu, Y., Kim, Y. L., & Backman, V. (2005) · Applied Optics · doi:10.1364/ao.44.002288 · Cited by 21
Gestational Age Correlates with Skin Reflectance in Newborn Infants of 24–42 Weeks Gestation
Lynn, C. J., Saidi, I. S., Oelberg, D. G., et al. (2009) · Biology of the Neonate · doi:10.1159/000243973 · Cited by 19
Olsen, J. B., & Sager, E. M. (1995) · British Journal of Radiology · doi:10.1259/0007-1285-68-806-160 · Cited by 8
Cited by
Why are double network hydrogels so tough?
Gong, J. P. (2010) · Soft Matter · doi:10.1039/b924290b · Cited by 2,328
Rare-earth-doped biological composites as in vivo shortwave infrared reporters
Naczynski, D. J., Tan, M. C., Zevon, M., Wall, B., Kohl, J., Kulesa, A., Chen, S., Roth, C. M., Riman, R. E., & Moghe, P. V. (2013) · Nature Communications · doi:10.1038/ncomms3199 · Cited by 759
Biomechanical Properties of In Vivo Human Skin From Dynamic Optical Coherence Elastography
Liang, X., & Boppart, S. A. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2033464 · Cited by 470
Light Sources and Dosimetry Techniques for Photodynamic Therapy
Kim, M. M., & Darafsheh, A. (2020) · Photochemistry and Photobiology · doi:10.1111/php.13219 · Cited by 454
Diffuse optical imaging using spatially and temporally modulated light
O’Sullivan, T. D., Cerussi, A. E., Cuccia, D. J., & Tromberg, B. J. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.17.7.071311 · Cited by 270
Metadata
- Authors
- Pogue, B. W., & Patterson, M. S.
- Venue
- Journal of Biomedical Optics
- Publisher
- SPIE-Intl Soc Optical Eng
- Published
- 2006
- Volume
- 11
- Issue
- 4
- Pages
- 041102
- ISSN
- 1083-3668 (ISSN-L)
- OpenAlex
- W2063461906
- Cited by
- 837
- References
- 89
- FWCI
- 14.86
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.