Binodal, wireless epidermal electronic systems with in-sensor analytics for neonatal intensive care
Open accessThe DOI matches its Crossref record; 44 of the 44 references it cites were found in a registry or an index; 12 of the 42 sources its claims cite were checked for support.
Abstract
Sensitive sensing Neonatal care, particularly for premature babies, is complicated by the infants' fragility and by the need for a large number of tethered sensors to be attached to their tiny bodies. Chung et al. developed a pair of sensors that only require water to adhere to the skin and allow for untethered monitoring of key vital signs (see the Perspective by Guinsburg). On-board data processing allowed for efficient wireless near-field communication using standard protocols. The absence of cables makes it easier to handle the infants and allows for skin-to-skin contact between the babies and their parents or caregivers. Science , this issue p. eaau0780 ; see also p. 924
Overview
CoChat Summary
TL;DR
The paper introduces a pair of ultrathin, wireless, battery-free epidermal electronic systems (EES) for neonatal intensive care: one chest-mounted ECG device and one foot-mounted PPG device. Pilot studies in neonates show clinical-grade agreement for heart rate, respiratory rate, and SpO₂, plus added capabilities for skin temperature and pulse arrival time as a systolic blood pressure surrogate.
Key findings
- The binodal EES continuously streams ECG, PPG, and skin temperature data, yielding HR, HRV, RR, SpO₂, and PAT; wireless data rates reach up to 800 bytes/s with dual channels, NFC operation works up to 25 cm through NICU materials, and BLE range reaches up to 20 m.
- The devices have effective moduli of 200 to 300 kPa, adhere via van der Waals forces, and show peel forces about a factor of ~10 lower than conventional NICU adhesives, with maximum von Mises stress on skin reduced by a factor of 4.3; the microfluidic channel reduces interfacial stresses by up to a factor of 2.5, and adhesion energy is G = 16 N/m.
- For MRI compatibility, mesh electrodes reduce the in-plane magnetic field gradient by a factor of ~3 and the out-of-plane gradient by a factor of 4 versus commercial electrodes; simulated copper heating is 1°C with maximum skin temperature change of 0.04°C, and experimental 3-T MRI measurements show ~0.1°C temperature difference, meeting FDA “MRI-safe” requirements.
- In neonates (n = 3, gestational age 28 to 40 weeks), mean differences versus standard-of-care monitors were –0.17 beats per minute for HR, 0.76 breaths per minute for RR, and 1.02% for SpO₂; additional studies in n = 18 neonates with gestational ages as low as 28 weeks and weights as low as 1470 g showed similar performance, and scaled production cost is estimated at less than $20 USD per unit.
Methods
- Fabrication used semiconductor processing, lamination, transfer printing, chip placement, and solder bonding; each EES includes serpentine Cu traces, chip-scale ICs, fractal mesh electrodes, an ionic-liquid microfluidic chamber, silicone encapsulation, and an NFC loop antenna for simultaneous wireless power and data.
- In-sensor analytics include a streamlined Pan-Tompkins algorithm for real-time QRS detection to yield HR and HRV, dynamic baseline control and SpO₂ calculation for PPG, and time-synchronized ECG/PPG processing for PAT.
- Validation included healthy adult volunteers (n = 3) against FDA-cleared monitoring equipment, and neonates in two tertiary-level NICUs: n = 3 with synchronous standard-of-care measurements and n = 18 using related device platforms with onboard power supplies; the protocol was IRB-approved and registered on ClinicalTrials.gov (NCT02865070).
Limitations
- The paper states that results are preliminary feasibility testing and validation; comprehensive clinical studies are ongoing to verify measurements across increased age groups and ethnic backgrounds, and remaining challenges include nursing acceptance, compatibility with legacy monitoring systems, and device sterilization for reuse.
- The paper notes that additional testing is needed for altered skin barrier function, such as burn victims or patients with epidermolysis bullosa.
- Evident from the text: the neonatal validation cohorts are small (n = 3 with synchronous standard-of-care comparisons; n = 18 using related platforms with onboard power supplies), adult validation is n = 3, and temperature and PAT data in neonates are shown without reference comparators because conventional devices acquire these only periodically.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Figures









Verification
Claims the paper makes
6 Valid · 2 Not valid · 18 Not checked · 82 Own results and interpretations
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“A key example is the measurement of pulse arrival time (PAT), defined by the time lapse between the maximum fiducial point in the ECG signal (R peak) and the corresponding minimal fiducial point in the PPG signal at valley as in Fig. 6H, as a direct correlate to systolic blood pressure (29 , 30).”
§ Binodal, wireless epidermal electronic systems with in-sensor analytics for neonatal intensive care > Real-time measurements, in-sensor analytics, and data transmission
What the sources say
- Partly supportedcites [29] Kim J. S., Chee Y. J., Park J. W., Choi J. W., Park K. S., A new approach for non-intrusive monitoring of blood pressure on a toilet seat. Physiol. Meas. 27, 203– 211 (2006). doi: 10.1088/0967-3334/27/2/010; pmid: 16400206 sourceExperimental — accuracy not yet measured
Section 4.1 reports that PAT was significantly, but moderately, correlated with systolic blood pressure. Section 2.2 defines the study’s PAT using the ECG R-peak and the PPG’s maximum first-derivative point, not the PPG valley; it says the minimum point was unclear in its signal. The claimed correlation is supported, but the attributed measurement definition is not. (LLM, conf=0.87)
- Not checked — no full text of the sourcecites [30] Geddes L. A., Voelz M. H., Babbs C. F., Bourland J. D., Tacker W. A., Pulse transit time as an indicator of arterial blood pressure. Psychophysiology 18, 71– 74 (1981). doi: 10.1111/j.1469-8986.1981.tb01545.x; pmid: 7465731 source
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“The inherently thin, soft mechanical properties of the sensors (Fig. 1A) reported here allow for adhesion via van derWaals forces alone.”
§ Binodal, wireless epidermal electronic systems with in-sensor analytics for neonatal intensive care > Low-modulus mechanics, soft interface adhesion, and implications for neonatal skin safety
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“The mechanical decoupling afforded by the microfluidic channel decreases these stresses by up to a factor of 2.5 (Fig. 2B) relative to otherwise similar designs without the microfluidics.”
§ Binodal, wireless epidermal electronic systems with in-sensor analytics for neonatal intensive care > Low-modulus mechanics, soft interface adhesion, and implications for neonatal skin safety
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Oscillations in the force only appear for holes larger than the characteristic size of the cohesive zone (~500 mm, as in Fig. 2I).”
§ Binodal, wireless epidermal electronic systems with in-sensor analytics for neonatal intensive care > Low-modulus mechanics, soft interface adhesion, and implications for neonatal skin safety
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Specifically, the interface starts to delaminate when the normal stress reaches ~20 kPa (Fig. 2G, inset).”
§ Binodal, wireless epidermal electronic systems with in-sensor analytics for neonatal intensive care > Low-modulus mechanics, soft interface adhesion, and implications for neonatal skin safety
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
61 more claims
Create a free account to see all 108 claims and to verify the 1 reference still open.
- Probably not a substantial claim. 14
- It may state two separate claims as one. 33
- The quote only partly states this claim. 2
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Researchers have developed various versatile epidermal electrodes with high performance that can universally measure EEG, EMG, EOG, and ECG through placing electrodes on different areas of the skin.[25,414]”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [414]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Previous reports validated the performance of an FDA-cleared physiological monitoring system against gold standard monitoring platforms [18–23].”
From Pregnancy outcomes in infertility patients diagnosed with sleep disordered breathing with wireless wearable sensors (2022) · cites this paper as [18]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“In previous work, we demonstrate the ability for the chest- and finger-mounted sensors to monitor vital signs in both children and adults; the abdominal sensor allows for maternal–fetal monitoring of pregnant women in both high- and low-resource settings as well as the clinical and home settings (22, 23).”
From Comprehensive pregnancy monitoring with a network of wireless, soft, and flexible sensors in high- and low-resource health settings (2021) · cites this paper as [23]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“and have been used in neonatal and pediatric intensive care units. 4,5”
From Advanced wireless monitoring for children in the cardiac perioperative setting (2023) · cites this paper as [4]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“However, this system is limited by (1) the modest maximum operating distances (~30 cm) supported by near-field communication (NFC) protocols used for power transfer and data communication, (2) the mechanically fragile nature of the ultrathin, compliant mechanics designs, (3) the sufficient, but constrained range of measurement capabilities, and (4) the demand for highly advanced device configur”
From Skin-interfaced biosensors for advanced wireless physiological monitoring in neonatal and pediatric intensive-care units (2020) · cites this paper as [9]
Experimental — accuracy not yet measured
5 more claims about this paper
Create a free account to see every claim other papers make about this one.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
Each contradiction between two passages listed here was confirmed by an independent check.
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
§ Binodal, wireless epidermal electronic systems with in-sensor analytics for neonatal intensive care > Compatibility with medical imaging techniques used in the NICU
“eliminating any parasitic heating from magnetically induced eddy currents.”
§ Binodal, wireless epidermal electronic systems with in-sensor analytics for neonatal intensive care > Compatibility with medical imaging techniques used in the NICU
“Full three-dimensional multi-physicsmodeling shows that, at the end of a single scan for 0.5 ms, the copper layer of an ECG EES undergoes heating by only 1°C (Fig. 3H).”
Citations
Cites
A Real-Time QRS Detection Algorithm
Pan, J., & Tompkins, W. J. (1985) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1985.325532 · Cited by 7,855
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087
Kim, D.-H., Lu, N., Ma, R., Kim, Y.-S., Kim, R.-H., Wang, S., Wu, J., Won, S. M., Tao, H., Islam, A., et al. (2011) · Science · doi:10.1126/science.1206157 · Cited by 4,836
Self-citationWearable Sensors for Remote Health Monitoring
Majumder, S., Mondal, T., & Deen, M. (2017) · Sensors · doi:10.3390/s17010130 · Cited by 1,375
Kiserud, T., Piaggio, G., Carroli, G., Widmer, M., Carvalho, J., Neerup Jensen, L., Giordano, D., Cecatti, J. G., Abdel Aleem, H., Talegawkar, S. A., et al. (2017) · PLOS Medicine · doi:10.1371/journal.pmed.1002220 · Cited by 729
Thermochemistry of ionic liquid heat-transfer fluids
Valkenburg, M. E. V., Vaughn, R. L., Williams, M., & Wilkes, J. S. (2005) · Thermochimica Acta · doi:10.1016/j.tca.2004.11.013 · Cited by 595
Halcox, J. P. J., Wareham, K., Cardew, A., Gilmore, M., Barry, J. P., Phillips, C., & Gravenor, M. B. (2017) · Circulation · doi:10.1161/circulationaha.117.030583 · Cited by 580
Self-assembled three dimensional network designs for soft electronics
Jang, K.-I., Li, K., Chung, H. U., Xu, S., Jung, H. N., Yang, Y., Kwak, J. W., Jung, H. H., Song, J., Yang, C., et al. (2017) · Nature Communications · doi:10.1038/ncomms15894 · Cited by 445
Self-citationChen, W., Kobayashi, T., Ichikawa, S., Takeuchi, Y., & Togawa, T. (2000) · Medical & Biological Engineering & Computing · doi:10.1007/bf02345755 · Cited by 425
Harris, K. D., Elias, A. L., & Chung, H.-J. (2016) · Journal of Materials Science · doi:10.1007/s10853-015-9643-3 · Cited by 403
Self-citation
Research works printed but not linked: 2
- O. Sharma, S. N. Lewis, U. Telang, L. D’Almeida, L. E. S. Lewis, Design of a Bluetooth Enabled Health Monitoring System for Infants Using Wearable Technology. J. Adv. Res. Dyn. Contrl. Syst. 15, 887–894 (2017). http://jardcs.org/papers/v9/sp/20181075.pdf
- C. H. Lund J. A. Tucker in Neonatal Skin: Structure and Function S. B. Hoath H. I. Maibach Eds. (Dekker ed. 2 2003) pp. 299–324.
Cited by
Items 601–700 of 800
Flexible Pressure Sensors with a Sandwich Structure Based on Vertical Graphene Nanowalls by HFCVD
Mao, W., Shen, H., Wang, Z., Liao, B., Zhang, J., Zhu, J., Li, Y., & Wu, T. (2022) · Journal of Electronic Materials · doi:10.1007/s11664-022-10101-2 · Cited by 6
Postbuckling analyses of ribbon-type 3D structures assembled on cylindrical substrates
Jin, T., Zhao, J., & Zhang, Y. (2024) · Acta Mechanica Sinica · doi:10.1007/s10409-024-24130-x · Cited by 5
Self-citationWearable microfluidic devices for multiplex body fluid monitoring
Sun, Y., Guo, X., Jiang, Y., Cui, J., Wu, J., Wang, J., Cheng, W. M., Shi, Y., & Pan, L. (2025) · The Analyst · doi:10.1039/d5an00739a · Cited by 5
Ding, L., Lin, Y. Q., Yang, C., & Kong, D. (2025) · Advanced Materials Technologies · doi:10.1002/admt.202501387 · Cited by 6
All‐Dry Self‐Adhesive Soft Electrodes with Subsurface Pores for Long‐Term Skin Recording
Jeon, M. S., Yi, J., Hong, S., Lee, J., Jang, H., Kim, B., Lee, H., Lee, C. H., & Kim, D. R. (2025) · Small · doi:10.1002/smll.202507416 · Cited by 6
Self-citationAccurate prediction of contact stiffnesses of irregular interfaces
Wang, Y., Chu, J., Yuan, J., Kang, G., Chen, W., & Li, X. (2025) · International Journal of Mechanical Sciences · doi:10.1016/j.ijmecsci.2025.110969 · Cited by 6
A battery-free wireless epidermal sensor network for continuous systolic blood pressure monitoring
Kurt, S. A., Kasper, K. A., Xu, Q., Yang, X. Y., Xiao, X., Zeng, Q., Stuart, T., Li, Z., Liu, Y., Song, J., et al. (2026) · Nature Electronics · doi:10.1038/s41928-026-01597-1 · Cited by 13
Highly conductive and ultrarobust elastic conductors for stretchable electronics
Zheng, T., Xiang, S., Shi, Q., Li, J., Wei, X., Liu, L., Xu, C., Duan, S., Chen, P., Xie, X., et al. (2026) · Science Advances · doi:10.1126/sciadv.aee8109 · Cited by 7
Sensor-Based Discovery of Search and Palpation Modes in the Clinical Breast Examination
Laufer, S., Klatzky, R. L., & Pugh, C. M. (2024) · Academic Medicine · doi:10.1097/acm.0000000000005614 · Cited by 5
Review of Wearable Antennas: Part 1: Materials, fabrication, and radiation characteristics.
Ye, Z., Zhao, G., Yang, M., & Chen, P. (2025) · IEEE Antennas and Propagation Magazine · doi:10.1109/map.2025.3530407 · Cited by 7
“Another widely employed strategy is to customize the metal materials as flexible and thin serpentine structures and integrate them with soft and stretch-able elastomers to construct antennas for wearable electronics and devices [3], [4], [28].”
InfluentialMorphable 3D architectures enabled by shear-guided approach
Li, K., Liu, Z., Hu, X., Xu, Z., Zhou, Y., Chen, L., Huang, Y. Y., Bo, R., & Zhang, Y. (2025) · Materials Today · doi:10.1016/j.mattod.2025.03.004 · Cited by 6
Self-citationMechanics and Strategies for Wrinkling Suppression: A Review
Zhang, Z., Zhao, L., & Shi, J. (2022) · Frontiers in Mechanical Engineering · doi:10.3389/fmech.2022.910415 · Cited by 8
Xia, L., Qian, J., Song, D., et al. (2022) · Advanced Materials Technologies · doi:10.1002/admt.202201223 · Cited by 5
Jiang, Q., Chai, Z., Zong, Z., Hu, Z., Zhang, S., & Wu, Z. (2023) · Chemosensors · doi:10.3390/chemosensors11030197 · Cited by 6
Interfacial fatigue fracture of elastomer bilayers under cyclic large deformation
Liu, J., Li, Y., Jiang, Z., Zhang, Q., Hu, N., Kang, G., & Qu, S. (2023) · Engineering Fracture Mechanics · doi:10.1016/j.engfracmech.2023.109295 · Cited by 8
Li, H., Yuan, J., Fennell, G., Abdulla, V., Nistala, R., Dandachi, D., Ho, K. C., & Zhang, Y. (2023) · Biophysics Reviews · doi:10.1063/5.0140900 · Cited by 6
Self-citationOptimal bilayer composites for temperature-tracking wireless electronics
Kim, D., Kim, W., Kim, J., Lee, H. K., Joo, J., Kim, B., Allen, M. G., Lu, D., Venkatesh, V., Huang, Y., et al. (2024) · Nanoscale · doi:10.1039/d3nr05784d · Cited by 5
Self-citationTwo-dimensional materials and hybrid systems for photodetection
Xiong, Z., & Tang, J. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-818475-2.00015-5 · Cited by 6
Ultraconformable organic devices
Ferrari, L. M., Taccola, S., Barsotti, J., Mattoli, V., & Greco, F. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-818890-3.00015-1 · Cited by 7
A New Light-to-Frequency Analog Front-End Circuit for Optical Sensing in Biomedical Applications
Stanchieri, G. D. P., Marcellis, A. D., Faccio, M., Palange, E., & Güler, Ü. (2021) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas49922.2021.9645038 · Cited by 5
Clinical Evaluation of a Wireless Device for Monitoring Vitals in Newborn Babies
Aggarwal, R., Gunaseelan, V., Manual, D., Sanker, M., & Prabaaker, S. (2023) · The Indian Journal of Pediatrics · doi:10.1007/s12098-022-04459-8 · Cited by 5
“Adult systems are minimally adapted for use in pediatrics and are limited by the use of rigid sensors that use strong adhesives to attach to the neonates’ skin and are connected to bulky units limiting movement of babies for feeding by mothers [15, 16].”
BackgroundXiong, K., Fan, C., He, D., Chen, H., Zhao, X., Xu, F., Zhang, Z., & Wu, X. (2025) · Energy · doi:10.1016/j.energy.2025.136434 · Cited by 5
Progress in the flexible and stretchable epidermal electrodes for wearable ECG monitoring
Ji, J., Su, T., Lu, J., Gao, X., & Zhang, L. (2025) · BME Horizon · doi:10.70401/bmeh.2025.0004 · Cited by 6
Wireless passive fabric sensor for multi-ion detection in human sweat
Xia, Z., Guo, F., Chen, X., Zhang, F., Zhang, Z., Li, J., Huang, L., Xu, Z., Ming, X., & Peng, Y. (2025) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2025.118090 · Cited by 7
Sénéchal, E., Maximov, A. G., Jeanne, E., Radeschi, D. J., Azevedo, V. M. G. D. O., Gross, A., Shalish, W., Kearney, R. E., & SantʼAnna, G. (2025) · Pediatric Research · doi:10.1038/s41390-025-04469-0 · Cited by 13
Advanced intelligent E-Skin: Multimodal sensing to AI-Driven clinical monitoring
Yu, Z., Feng, J., Dou, W., Ge, X., He, D., Zhang, M., Wang, H., & Zhou, Y. (2026) · Materials Today · doi:10.1016/j.mattod.2026.103211 · Cited by 5
Zha, X., Li, Q.-K., Chen, P., Liu, Y., Huang, J., Li, J.-B., & Zhou, Y. (2026) · Chemical Engineering Journal · doi:10.1016/j.cej.2026.175026 · Cited by 5
Ding, Y., Cui, W., Wu, J., et al. (2025) · Materials Today Communications · doi:10.1016/j.mtcomm.2025.113223 · Cited by 4
Advances in Skin-interfaced Wireless Physiological Monitoring Systems
Lim, E. S., Lee, S. H., Choi, J., Lim, Y.-J., & Chung, H. U. (2025) · Journal of Sensor Science and Technology · doi:10.46670/jsst.2025.34.5.458 · Cited by 5
Self-citationChetyrkina, M. R., Cvjetinovic, J., Fedorov, F. S., Perevoschikov, S. V., Сергеевна, П. Е., Mikladal, B. F., Gladush, Y. G., Nasibulin, A. G., & Gorin, D. A. (2022) · ACS Photonics · doi:10.1021/acsphotonics.2c01074 · Cited by 4
Baby Sock to Monitor Newboms to Detect Risk for Neonatal Compromise
Hode, P. K., Gulick, D. W., Devoe, L. D., et al. (2024) · Conference proceedings · doi:10.1109/mwscas60917.2024.10658791 · Cited by 4
“Recently, a wireless, stick-on biosensor for neonatal care has been developed and tested on neonates [10].”
BackgroundWang, S., Dong, M., He, J., Wu, G., Li, X., Pan, X., Wu, J., Bao, R., & Pan, C. (2025) · Microelectronic Engineering · doi:10.1016/j.mee.2025.112346 · Cited by 5
Stretchable thin film inductors for wireless sensing in wearable electronic devices
Ding, X., Shen, E., Zhu, Y., & Moran-Mirabal, J. M. (2022) · Flexible and Printed Electronics · doi:10.1088/2058-8585/ac8c50 · Cited by 6
“Wired connections can also complicate the most basic bedside tasks and interrupt the user’s routine activities [2].”
BackgroundWireless and Multi‐Person Respiration Monitoring using Facemask‐Integrated Flexible Meta‐Antennas
Zheng, Z., Xu, J., Li, Z., Xu, W., Wang, C., Yin, P., Zou, Y., Zhang, Y., Zhou, Z., Gan, G., et al. (2023) · Advanced Materials Technologies · doi:10.1002/admt.202202096 · Cited by 7
Self-citationDevices based on photoplethysmogram and pulse oximetry
Bolić, M. (2023) · Elsevier eBooks · doi:10.1016/b978-0-12-820947-9.00002-7 · Cited by 5
Inorganic Flexible Electronics: Materials, Strategies, and Applications
Qinglei, G., & Di, Z. (2022) · Wiley eBooks · doi:10.1002/9783527813933.ch4 · Cited by 5
Noninvasive Heart Rate and Respiration Rate Detection Enabled by Perovskite Single Crystal Detector
Chen, Y., Huang, L., Cui, Y., Ji, Y., Huang, Z., Liu, T., Liu, J., Ma, X., Tan, P., Hao, Y., et al. (2026) · Advanced Functional Materials · doi:10.1002/adfm.202516873 · Cited by 4
Self-citationMa, K., Zeng, R., Chen, S., Zhang, Y., Wang, J., Hu, X., Jiang, Y., Xu, H., Pan, H., Mei, D., et al. (2026) · Nano-Micro Letters · doi:10.1007/s40820-026-02071-5 · Cited by 3
Self-citationSun, Y., Zhang, B., Zhao, H., et al. (2023) · Journal of Physics D Applied Physics · doi:10.1088/1361-6463/acbce0 · Cited by 3
AI plays a crucial role in the diagnosis and prognosis cardio pregnant women
Hilal, S. (2024) · Elsevier eBooks · doi:10.1016/b978-0-443-22008-1.00010-5 · Cited by 3
Progress in the Assessment of Arterial Stiffness
Bolić, M., Dajani, H. R., Yoshida, M., & Groza, V. Z. (2021) · IEEE Instrumentation & Measurement Magazine · doi:10.1109/mim.2021.9400954 · Cited by 3
“New research on PPG sensors includes ultrathin, soft, skin-like electronic patch devices [15] as well as devices with a large number of LEDs and photodiodes (up to 16) placed in different orientations.”
BackgroundFlexible Electrodes as a Measuring System of Electrical Impedance Imaging
Wang, Y., Ping, X., Chen, X., & Wang, D. (2023) · Materials · doi:10.3390/ma16051901 · Cited by 3
Noninvasive medical microsystems on flexible substrates
Moghimi, M. J., Lim, E., Akula, C. R., Imtiaz, H., & Ray, E. (2023) · Microfluidics, BioMEMS, and Medical Microsystems · doi:10.1117/12.2657653 · Cited by 3
Liu, G., Xu, C., Ren, J., Liu, Y., Yao, L., Xie, Y., Zhang, T., & Liu, Y. (2023) · Journal of Materials Science Materials in Electronics · doi:10.1007/s10854-023-10599-0 · Cited by 3
Understanding the Challenges Nurses Encounter with Monitoring Technologies in a NICU
Venkatasubramanian, K., Ranalli, T.-M., Kirupaharan, P., Solanki, D., & Mankodiya, K. (2023) · International Journal of Human-Computer Interaction · doi:10.1080/10447318.2023.2278297 · Cited by 5
“Recent work in designing pulse oximeters for the NICU is a great start in this regard (Chung et al., 2019).”
Curvature-Matching Mechanics in Skin-Based Bioelectronics to Minimize Interfacial Stresses
Avila, R. O. (2023) · Journal of Applied Mechanics · doi:10.1115/1.4064211 · Cited by 4
Wireless wearable devices for continuous monitoring of body sounds and motions
Kim, S. H., Jeanne, E., Shalish, W., Yoo, J., & Rogers, J. A. (2024) · Clinical and Translational Medicine · doi:10.1002/ctm2.1593 · Cited by 4
Self-citationSkin‐Inspired in‐Sensor Encoding of Strain Vector Using Tunable Quantum Geometry
Liu, Z., Shi, J., Cao, J., Ma, Z., Yang, Z.-Z., Cui, Y., Wang, L., Dai, Y., Chen, M., Wang, P., et al. (2024) · Advanced Functional Materials · doi:10.1002/adfm.202416204 · Cited by 6
Self-citationFlexible Dual chip on-skin RFID Sensor for Body Temperature Monitoring
Occhiuzzi, C., Parrella, S., & Marrocco, G. (2020) · IEEE International Conference on Flexible and Printable Sensors and Systems (FLEPS) · doi:10.1109/fleps49123.2020.9239531 · Cited by 3
“The possibility to collect information on the personal healthstate directly and seamlessly from the human body skin is nowadays becoming real and feasible [1], especially thanks to the continuous progresses in low power and epidermal electronics [2].”
BackgroundUltra-thin PZT/Si chip integrated on paper substrates
Yamashita, T., Takeshita, T., Oouchi, A., & Kobayashi, T. (2021) · Japanese Journal of Applied Physics · doi:10.35848/1347-4065/ac1386 · Cited by 3
Multichip RFID Epidermal Sensor for Body Temperature Monitoring
Parrella, S., Occhiuzzi, C., & Marrocco, G. (2020) · European Conference on Antennas and Propagation · doi:10.23919/eucap48036.2020.9135880 · Cited by 3
“The possibility to collect information on the personal healthstate directly and seamlessly from the human body skin is nowadays becoming real and feasible [1], especially thanks”
BackgroundArrhythmia Classification Algorithm Based on Multi-Feature and Multi-type Optimized SVM
Li, H., Wei, X., Zuo, S., et al. (2020) · American Scientific Research Journal for Engineering, Technology, and Sciences · Cited by 3
Nan, K., Wong, K., Li, D., et al. (2024) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2024.04.25.591220 · Cited by 3
Advanced wireless monitoring for children in the cardiac perioperative setting
Chen, H., Soetikno, A., Xu, S., Suresh, S., & Walter, J. R. (2023) · Pediatric Anesthesia · doi:10.1111/pan.14684 · Cited by 2
Self-citationA Laser-Induced Graphene-Based Flexible Multimodal Sensor for Material and Texture Perception
Duo, Y., Duan, J., Chen, X., Liu, W., Wang, S., & Li, W. (2024) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros58592.2024.10802515 · Cited by 3
“In the last few years, flexible sensors have attracted great attention and have been under intensive investigation for their remarkable applications in areas including health monitoring [1], prosthetics [2], and robotics [3].”
Zhang, A., Tessier, A., & Ameri, S. K. (2025) · Advanced Materials Technologies · doi:10.1002/admt.202402189 · Cited by 2
Methods to Validate Digital Health Technologies for Dermatology
Park, J. J.-Y., Richards, D., Tseng, P.-H., Ebata, T., Ikoma, A., Vakharia, P. P., Rangel, S. M., Paller, A. S., & Xu, S. (2025) · Journal of Investigative Dermatology · doi:10.1016/j.jid.2025.08.013 · Cited by 2
Self-citationKim, J. U., Hyun, J., Koirala, G. R., Kim, J., Kim, S., Im, G., Kim, Y. H., Kim, Y. G., Lee, D., Park, H. S., et al. (2025) · Advanced Science · doi:10.1002/advs.202515490 · Cited by 2
Self-citationMultimodal flexible sensor system toward telediagnosis
Lee, D. H., & Takei, K. (2026) · Proceedings of the Japan Academy Series B · doi:10.2183/pjab.102.004 · Cited by 2
Machine Learning-Empowered Depression Detection With Wearable Skin Electronics: A Review
Xu, Y., Zhao, Z., Zhu, H., Lai, S., Jia, Y., & Liu, G. (2026) · IEEE Sensors Journal · doi:10.1109/jsen.2026.3660322 · Cited by 3
“For instance, Chung et al. [96] demonstrated a binodal monitoring system where anatomically distributed ECG and PPG modules share standardized wireless protocols and time-synchronized streaming.”
Self-citationKim, H. J., Kim, S., Yeo, C., Kim, M., Shin, W., & Kim, J. (2026) · Scientific Reports · doi:10.1038/s41598-026-38764-5 · Cited by 3
Self-citationChoi, M., Kim, Y., Han, H., Byeon, G., Lee, Y., Han, J. A., Lee, N. H., Kim, S. W., Lee, H., Loh, Y., et al. (2026) · Materials Horizons · doi:10.1039/d5mh02270c · Cited by 4
Self-citationStimulation Modalities in Wearable Haptic Systems: Single-Mode Feedback to Multiphysics Actuation
Guo, X. M., Avila, R. O., Wu, Z., Wang, X., Xu, P., Ju, P., Yang, Q., Liu, P., Choi, S., Nikitsin, A. V., et al. (2026) · Research · doi:10.34133/research.1192 · Cited by 4
“These actuators offer efficient and precise tunable haptic feedback across diverse platforms [ 91 , 92 ].”
Self-citationStretchable Antennas for Wearable Application: Materials Guideline With Design Considerations
Low, J.-H., Lim, E.-H., & Chee, P. S. (2026) · IEEE Journal of Radio Frequency Identification · doi:10.1109/jrfid.2026.3671254 · Cited by 3
“These sensors are usually coupled with wearable antennas to enable data communication in the Internet of Things (IoT) ecosystems [8], [9], [10], e ff ectively eliminating the need for physical wires [11], [12].”
Massively parallel in-sensor skinomorphic computing
Li, Y., Yang, Y., Wang, C., Dai, Y., Yan, X., Kong, D., Liao, Z., Wang, S., Ruan, G.-J., Wang, P., et al. (2026) · Nature Communications · doi:10.1038/s41467-026-71697-1 · Cited by 7
Multidirectional strain-insensitive stretchable RF electronics
Yang, F., Zhang, S., Zhang, J., Tong, Y., Zhong, J., Zheng, J., Li, J., Hu, Y., Yuan, Y., Zhu, J., et al. (2026) · Nature Communications · doi:10.1038/s41467-026-74900-5 · Cited by 3
Zhang, F., Xu, Z., Hou, C., Yin, L., Yin, M., Lian, M., He, W., Li, S., Cheng, P., & Huang, Y. (2026) · Science Advances · doi:10.1126/sciadv.aee4065 · Cited by 5
Self-citationA Novel Light-to-Frequency Converter Based Analog Front-End for Optical Sensing Applications
Stanchieri, G. D. P., Marcellis, A. D., Faccio, M., Palange, E., & Güler, Ü. (2021) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/sensors47087.2021.9639515 · Cited by 2
“Among them, optical electrodes (optrodes [4]) have found extensive use in applications such as photoplethysmography (PPG) [5,6], transcutaneous blood gas monitoring [7,8], and neural interfaces [4,9].”
Background11‐5: Invited Paper: Evolving into an Era of Natively Flexible Smart Systems
Costa, J. C., Barlier, V. S., Norman, H., Özer, E., Alkhalil, F. M., & Price, R. (2023) · SID Symposium Digest of Technical Papers · doi:10.1002/sdtp.16507 · Cited by 2
Gao, Z., Zhang, Y., Hu, Z., Zhang, D., Li, S., Xiao, H., Xiang, Z., Xu, D., Zhang, H., Wu, Y., et al. (2024) · Carbon Energy · doi:10.1002/cey2.640 · Cited by 2
Self-citationAdvancing Neonatal Care: A Deep Learning Approach for Non-Contact Heart Rate Monitoring
Grafton, A., Castelblanco, A., Warnecke, J. M., Thomson, L., Schubert, B., Hilgendorff, A., Schnabel, J. A., Lasenby, J., & Beardsall, K. (2024) · IEEE International Conference on e-Health Networking, Applications and Services (Healthcom) · doi:10.1109/healthcom60970.2024.10880770 · Cited by 3
“Moreover, the attachment of a large number of wired sensors to the infant can obstruct basic care tasks and highly limit parental bonding [3], [4].”
RF-Free infant ECG monitoring: Performance and signal quality assessment
Chehbani, A., Sahuguede, S., & Julien‐Vergonjanne, A. (2022) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc48229.2022.9871387 · Cited by 4
“ECG monitoring has progressed thanks to the continuous evolution of new technologies, which has led to the development of wearable and wireless sensor systems allowing continuous monitoring of the ECG signal with automatic detection of abnormalities in neonatology [1] and for supervision of children [2].”
BackgroundOrganic-inorganic heterostructures for stretchable electronics
Rojas, J. P. (2019) · Micro- and Nanotechnology Sensors, Systems, and Applications · doi:10.1117/12.2519017 · Cited by 2
Disorders in the neonatal period
Revenis, M. E., & Wong, E. C. C. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-817962-8.00006-8 · Cited by 2
A Wireless Fully-Passive Acquisition of Biopotentials
Liu, S., Meng, X., Zhang, J., & Chae, J. (2021) · Methods in molecular biology · doi:10.1007/978-1-0716-1803-5_45 · Cited by 2
Wireless sensors for the tiniest patients
Miller, J. L. (2019) · Physics Today · doi:10.1063/pt.3.4197 · Cited by 2
Editorial for the Special Issue on Wearable and Implantable Bio-MEMS Devices and Applications
Ji, B., & Gao, K. (2024) · Micromachines · doi:10.3390/mi15080955 · Cited by 2
Self-citationSoft, all-in-one, nanomembrane wearable system for advancing neonatal health monitoring in Ethiopia
Zhou, L., Joseph, M., Lee, Y. J., Yadav, D., Nayak, L., Woodall, J., Matthews, J., Soltis, I., Mekuria, F. M., Yeshanew, K. H., et al. (2025) · npj Digital Medicine · doi:10.1038/s41746-025-01974-8 · Cited by 3
“Previous wearables have been designed to condense the complicated setups in NICU monitoring into miniaturized wearables for facilitated monitoring 4 – 6 ; however, they encounter problems with device longevity with either single-use or short-term use before replacement.”
Self-citationFlexible Parametric Speaker with Ultra-Thin PZT/Si MEMS Chips Integrated On Paper Substrate
Kobayashi, T., Takeshita, T., & Oouchi, A. (2022) · Proceedings, IEEE micro electro mechanical systems · doi:10.1109/mems51670.2022.9699710 · Cited by 1
Skin‐customized wearable device adhesive without skin damage
Lee, B., Park, M., & Kim, B. H. (2023) · Journal of Applied Polymer Science · doi:10.1002/app.54967 · Cited by 1
Self-citationLi, X., Li, M., Qin, X., Li, Y., Wang, Y., Han, C., Ni, S., Sun, X., Dong, P., & Liu, J. (2024) · Frontiers in Pediatrics · doi:10.3389/fped.2023.1297563 · Cited by 1
Intrinsically stretchable electronics with high performance and large integration scale
Wang, Y., Huang, R., Wang, W., & Hu, Y. (2024) · 中国科学通报:英文版 · doi:10.1016/j.scib.2024.04.070 · Cited by 1
Thull, R., Goedicke‐Fritz, S., Schmiech, D., Marnach, A., Müller, S. N., Körbel, C., Laschke, M. W., Tutdibi, E., Nourkami‐Tutdibi, N., Kaiser, E., et al. (2024) · Biosensors · doi:10.3390/bios14090437 · Cited by 2
“In the search for better ways to monitor such vulnerable infants without causing distress, contactless measurement methods are becoming increasingly important [4,6].”
BackgroundReimagining apnea monitoring in the neonatal ICU
Jeanne, E., Alvaro, R. E., & Shalish, W. (2024) · Current Opinion in Pediatrics · doi:10.1097/mop.0000000000001432 · Cited by 1
Sénéchal, E., Radeschi, D. J., Kearney, R. E., Shalish, W., & SantʼAnna, G. (2025) · American Journal of Perinatology · doi:10.1055/a-2604-8329 · Cited by 4
Review of Self-Powered Wireless Sensors by Triboelectric Breakdown Discharge
Liu, S., Yi, J., Jiang, G., Hou, J., Yang, Y., Li, G., Sun, X., & Wen, Z. (2025) · Micromachines · doi:10.3390/mi16070765 · Cited by 2
Hua, J., Su, M., Cheng, W. M., Shi, Y., & Pan, L. (2025) · Review of Materials Research · doi:10.1016/j.revmat.2025.100089 · Cited by 5
Integrated Bioelectronics for Precision Health Monitoring
Xu, Y., Lee, M. S., Balaji, A., Uppal, A., Djassemi, O., Zhang, Y., Zhao, H., & Cauwenberghs, G. (2025) · Springer eBooks · doi:10.1007/978-981-95-2117-3_12 · Cited by 2
Self-citationWearable Flexible Triboelectric Sensor Array for a Self-Powered Infant Care System
Zheng, M., Chen, L., Ruan, L., et al. (2025) · ACS Omega · doi:10.1021/acsomega.5c08776 · Cited by 1
Yunxia, 赵. Z., Nan, 张. Z., Huayu, 欧. O., Zhengyu, 易. Y., Ning, 栗. L., He, 陈. C., Yining, 刘. L., Zhaoxuan, 胡. H., Zhaoxian, 苏. S., Lingling, 黄. H., et al. (2025) · Laser & Optoelectronics Progress · doi:10.3788/lop250784 · Cited by 1
Wu, X., Zhu, C., Zheng, L., Song, Y., Wang, J., Zhang, X., Yao, Z., Han, Y., Wang, Z., Jiang, Z., et al. (2026) · Nature Sensors · doi:10.1038/s44460-026-00044-0 · Cited by 8
Self-citationWang, Z., Jiang, C., An, Z., & Guo, R. (2026) · Science China Technological Sciences · doi:10.1007/s11431-025-3096-y · Cited by 1
Manufacturing, Sensing, and Applications of Data Gloves: A Review
Shao, S., Li, M., Hu, Y., & Li, M. (2026) · IEEE Sensors Journal · doi:10.1109/jsen.2026.3681433 · Cited by 2
“Leveraging reinforcement learning and transfer learning algorithms, data gloves can adapt to different user action habits and physiological characteristics, dynamically optimizing recognition models [192], [193].”
A Flexible Copper Electrode Array for High-Density Surface Electromyography
Li, C. Z., Lu, C., Li, J., & Guo, K. (2026) · Bioengineering · doi:10.3390/bioengineering13040467 · Cited by 1
Gonzalez, J. M., Ortiz, R., Amezcua, K.-L., Bedolla, C. N., Torres, S. I. H., Weitzel, E. K., Gorantla, V. S., Li, W., Aranyosi, A. J., Rogers, J. A., et al. (2026) · Sensors · doi:10.3390/s26082513 · Cited by 1
Self-citationLi, X., Tang, W., Wang, M., Moretti, G., Lin, J., & Shi, C. (2026) · Soft Matter · doi:10.1039/d6sm00123h · Cited by 1
Mei, J., Yang, Q., Tian, M., Deng, S., & Gong, Y. (2026) · Journal of Intensive Medicine · doi:10.1016/j.jointm.2026.03.004 · Cited by 1
From Materials Design to Device Assembly: Advanced Biosensors for Smart Healthcare
Xiao, Y., Sun, Y., Sun, T., Huang, G., Zhao, Z., & Xuanyong, L. I. U. (2026) · Advanced Functional Materials · doi:10.1002/adfm.75931 · Cited by 7
Pan, Y., Zou, B., Chen, H. H., Yao, D., Zhu, J., Xu, H. M., Xie, R., Gui, X., Tao, K., Huang, Z.-P., et al. (2026) · Advanced Functional Materials · doi:10.1002/adfm.202532013 · Cited by 1
Castelblanco, A., Ruggeri, E., Matzeu, G., Heydarian, M., Foerster, K., Bahnasy, A., Flemmer, A., Schnabel, J. A., Schubert, B., Omenetto, F. G., et al. (2026) · ACS Sensors · doi:10.1021/acssensors.5c04171 · Cited by 1
Metadata
- Authors
- Chung, H. U., Kim, B. H., Lee, J. Y., Lee, J., Xie, Z., Ibler, E. M., Lee, K., Banks, A., Jeong, J. Y., Kim, J., Ogle, C., Grande, D., Yu, Y., Jang, H., Assem, P., Ryu, D., Kwak, J. W., Namkoong, M., Park, J. B., Lee, Y., Kim, D. H., Ryu, A., Jeong, J., You, K., Ji, B., Liu, Z., Huo, Q., Feng, X., Deng, Y., Xu, Y., Jang, K.-I., Kim, J., Zhang, Y., Ghaffari, R., Rand, C. M., Schau, M., Hamvas, A., Weese-Mayer, D. E., Huang, Y., Lee, S. M., Lee, C. H., Shanbhag, N. R., Paller, A. S., Xu, S., & Rogers, J. A.
- Affiliations
- Northwestern University (US)
- University of Illinois Urbana-Champaign (US)
- Department of Materials Science and Engineering, Northwestern University, Evanston, IL 60208, USA.
- Agency for Science, Technology and Research (SG)
- Tsinghua University (CN)
- Daegu Gyeongbuk Institute of Science and Technology (KR)
- Lurie Children's Hospital (US)
- Center for Autonomic Medicine, Department of Pediatrics, Ann & Robert H. Lurie Children’s Hospital of Chicago, Chicago, IL 60611, USA.
- Kookmin University (KR)
- Purdue University West Lafayette (US)
- Corresponding author
- Chung, Ha Uk
- Kim, Bong Hoon
- Lee, Jong Yoon
- Lee, Jungyup
- Xie, Zhaoqian
- Paller, Amy S.
- Xu, Shuai
- Rogers, John A.
- ORCID
- Chung, Ha Uk
- Kim, Bong Hoon
- Lee, Jong Yoon
- Lee, Jungyup
- Xie, Zhaoqian
- Lee, KunHyuck
- Banks, Anthony
- Jeong, Ji Yoon
- Kim, Jongwon
- Grande, Dominic
- Yu, Yongjoon
- Jang, Hokyung
- Assem, Pourya
- Kwak, Jean Won
- Namkoong, Myeong
- Park, Jun Bin
- Lee, Yechan
- Kim, Do Hoon
- Ryu, Arin
- You, Kevin
- Ji, Bowen
- Liu, Zhuangjian
- Huo, Qingze
- Feng, Xue
- Deng, Yujun
- Xu, Yeshou
- Jang, Kyung-In
- Kim, Jeonghyun
- Zhang, Yihui
- Ghaffari, Roozbeh
- Rand, Casey M.
- Hamvas, Aaron
- Huang, Yonggang
- Lee, Seung Min
- Lee, Chi Hwan
- Shanbhag, Naresh R.
- Paller, Amy S.
- Xu, Shuai
- Rogers, John A.
- Venue
- Science
- Published
- 2019-03
- Volume
- 363
- Issue
- 6430
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- PMC
- PMC6510306
- OpenAlex
- W2916533817
- Semantic Scholar
- b0511afac0cc252946aa8f08a078b12e48030581
- Cited by
- 807
- References
- 43
- Citations by year
- 2026: 72 · 2025: 112 · 2024: 103 · 2023: 121 · 2022: 124 · 2021: 131 · 2020: 97 · 2019: 47
- FWCI
- 35.10
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- cc-by
- Locations
- Science (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Funders
- Bill and Melinda Gates Foundation (OPP1182909)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
- Keywords
- epidermal electronics, neonatal intensive care, battery-free operation, neonatal monitoring
- MeSH terms
- Diagnostic Imaging, Electronics, Equipment Design, Humans, Infant, Newborn, Monitoring, Physiologic, Skin, Intensive Care, Neonatal, Vital Signs, Lab-On-A-Chip Devices, Wireless Technology
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
The claim verdicts this report counts are experimental: their accuracy is not yet measured.
A language model drew the claims from the paper on 2026-10-10, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-10 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (gpt-6-sol).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.