Selective motor unit recruitment via intrafascicular multielectrode stimulation
The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
Recruitment of force via independent asynchronous firing of large numbers of motor units produces the grace and endurance of physiological motion. We have investigated the possibility of reproducing this physiological recruitment strategy by determining the selectivity of access to large numbers of independent motor units through intrafascicular multielectrode stimulation (IFMS) of the peripheral nerve. A Utah Slanted Electrode Array containing 100, 0.5–1.5 mm-long penetrating electrodes was inserted into the sciatic nerve of a cat, and forces generated by the 3 heads of triceps surea in response to electrical stimulation of the nerve were monitored via force transducers attached to their tendons. We found a mean of 17.4 ± 4.9 (mean ± SEM) electrodes selectively excited maximal forces in medial gastrocnemius before exciting another muscle. Among electrodes demonstrating selectivity at threshold, a mean of 7.3 ± 2.7 electrodes were shown to recruit independent populations of motor units innervating medial gastrocnemius (overlap < 20%). Corresponding numbers of electrodes were reported for lateral gastrocnemius and soleus, as well. We used these stimulation data to emulate physiological recruitment strategies, and found that independent motor unit pool recruitment approximates physiological activation more closely than does intensity-based recruitment or frequency-based recruitment.Key words: functional neuromuscular stimulation (FNS), microelectrode array, neuroprosthesis, intrafascicular multielectrode stimulation (IFMS).
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Stimulation can produce undesirable side effects, such as cocontraction of muscles [11,12] or unnatural sensory percepts [8,13].”
From Fascicle specific targeting for selective peripheral nerve stimulation (2019) · cites this paper as [11]
Citations
Cites
Physiological types and histochemical profiles in motor units of the cat gastrocnemius
Burke, R. E., Levine, D. N., Tsairis, P., & Zajac, F. E. (1973) · The Journal of Physiology · doi:10.1113/jphysiol.1973.sp010369 · Cited by 1,565
The effects of length and stimulus rate on tension in the isometric cat soleus muscle
Rack, P. M. H., & Westbury, D. R. (1969) · The Journal of Physiology · doi:10.1113/jphysiol.1969.sp008923 · Cited by 1,144 · cited 2×
“The force generated by a muscle is a function of the size of this activated population, the type of the muscle fibers activated (fast-twitch or slow-twitch, oxidative (fatigue-resistant) or glycolytic (fatigable)), the size of individual excited motor units, and their firing frequencies (Rack and Westbury 1969; Burke…”
BackgroundCampbell, P. K., Jones, K. E., Huber, R. J., Horch, K. W., & Normann, R. A. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.83588 · Cited by 881 · cited 1×
“The recent development of new electrode array architectures (Branner et al. 2001; Campbell et al. 1991; Hoogerwerf and Wise 1994; McCreery et al. 1997; Rutten et al. 1991; Tyler and Durand 2002; Yoshida and Horch 1993b) offers the potential to achieve highly selective muscle activation.”
BackgroundSelf-citationForces produced by medial gastrocnemius and soleus muscles during locomotion in freely moving cats.
Walmsley, B., Hodgson, J. A., & Burke, R. E. (1978) · Journal of Neurophysiology · doi:10.1152/jn.1978.41.5.1203 · Cited by 722
Functionally selective peripheral nerve stimulation with a flat interface nerve electrode
Tyler, D. J., & Durand, D. M. (2002) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2002.806840 · Cited by 398 · cited 2×
“1997), slowly penetrating interfascicular cuff electrodes (Tyler and Durand 1997) and flat interface electrodes (Tyler and Durand 2002; Hoffer et al. 2000).”
BackgroundA three-dimensional microelectrode array for chronic neural recording
Hoogerwerf, A. C., & Wise, K. D. (1994) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.335862 · Cited by 371
Selective Stimulation of Cat Sciatic Nerve Using an Array of Varying-Length Microelectrodes
Branner, A., Stein, R. B., & Normann, R. A. (2001) · Journal of Neurophysiology · doi:10.1152/jn.2001.85.4.1585 · Cited by 359 · cited 3×
“The manufacturing processes for the USEA implanted in these experiments has been reported elsewhere (Branner et al. 2001).”
BackgroundMethodSelf-citationIsometric force production by motor units of extensor digitorum communis muscle in man
Monster, A. W., & Chan, H. (1977) · Journal of Neurophysiology · doi:10.1152/jn.1977.40.6.1432 · Cited by 320
A method for pneumatically inserting an array of penetrating electrodes into cortical tissue
Rousche, P. J., & Normann, R. A. (1992) · Annals of Biomedical Engineering · doi:10.1007/bf02368133 · Cited by 306
Self-citationA multielectrode array for intrafascicular recording and stimulation in sciatic nerve of cats
Branner, A., & Normann, R. A. (2000) · Brain Research Bulletin · doi:10.1016/s0361-9230(99)00231-2 · Cited by 234
Self-citation
Research works printed but not linked: 2
- Crago P.E., 1996, J. Rehab. Res. Dev., 33, 158
- Vilensky J.A., 1998, Science, 26, 2031
Cited by
Evaluation of novel stimulus waveforms for deep brain stimulation
Foutz, T. J., & McIntyre, C. C. (2010) · Journal of Neural Engineering · doi:10.1088/1741-2560/7/6/066008 · Cited by 158
Non-rectangular waveforms for neural stimulation with practical electrodes
Sahin, M., & Tie, Y. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/3/008 · Cited by 157
Selective stimulation of the human femoral nerve with a flat interface nerve electrode
Schiefer, M. A., Polasek, K. H., Triolo, R. J., Pinault, G. C. J., & Tyler, D. J. (2010) · Journal of Neural Engineering · doi:10.1088/1741-2560/7/2/026006 · Cited by 130
New functional electrical stimulation approaches to standing and walking
Mushahwar, V. K., Jacobs, P. L., Normann, R. A., Triolo, R. J., & Kleitman, N. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/3/s05 · Cited by 124
Self-citationInterfacing the Somatosensory System to Restore Touch and Proprioception: Essential Considerations
Weber, D. J., Friesen, R., & Miller, L. E. (2012) · Journal of Motor Behavior · doi:10.1080/00222895.2012.735283 · Cited by 98
Davis, T. S., Parker, R. A., House, P. A., Bagley, E., Wendelken, S., Normann, R. A., & Greger, B. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/6/065003 · Cited by 91
Self-citationTorab, K., Davis, T. S., Warren, D. J., House, P. A., Normann, R. A., & Greger, B. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/3/035001 · Cited by 90
Self-citationIntraspinal microstimulation for the recovery of function following spinal cord injury
Bamford, J. A., & Mushahwar, V. K. (2011) · Progress in brain research · doi:10.1016/b978-0-444-53815-4.00004-2 · Cited by 89
Recording sensory and motor information from peripheral nerves with Utah Slanted Electrode Arrays
Clark, G. A., Ledbetter, N. M., Warren, D. J., & Harrison, R. R. (2011) · 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2011.6091149 · Cited by 72
Self-citationJia, X., Koenig, M. A., Zhang, X., Zhang, J., Chen, T., & Chen, Z. (2007) · The Journal of Hand Surgery · doi:10.1016/j.jhsa.2007.02.021 · Cited by 70
Motor-commands decoding using peripheral nerve signals: a review
Hong, K.-S., Aziz, N., & Ghafoor, U. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aab383 · Cited by 63
Schiefer, M. A., Freeberg, M., Pinault, G. J. C., Anderson, J., Hoyen, H., Tyler, D. J., & Triolo, R. J. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/5/056006 · Cited by 57
Schiefer, M. A., Tyler, D. J., & Triolo, R. J. (2012) · Journal of Computational Neuroscience · doi:10.1007/s10827-011-0381-5 · Cited by 53
Christensen, M. B., Wark, H. A. C., & Hutchinson, D. T. (2016) · Biomaterials · doi:10.1016/j.biomaterials.2015.11.012 · Cited by 49
Regenerated sciatic nerve axons stimulated through a chronically implanted macro-sieve electrode
MacEwan, M. R., Zellmer, E. R., Wheeler, J. J., Burton, H., & Moran, D. W. (2016) · Frontiers in Neuroscience · doi:10.3389/fnins.2016.00557 · Cited by 48
Fascicle specific targeting for selective peripheral nerve stimulation
Overstreet, C. K., Cheng, J., & Keefer, E. W. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab4370 · Cited by 44
Optimization of selective stimulation parameters for multi-contact electrodes
Fisher, L. E., Tyler, D. J., & Triolo, R. J. (2013) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-10-25 · Cited by 45
Selective neural activation in a histologically derived model of peripheral nerve
Butson, C. R., Miller, I. O., Normann, R. A., & Clark, G. A. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/3/036009 · Cited by 42
Self-citationNormann, R. A., Dowden, B. R., Frankel, M. A., Wilder, A. M., Hiatt, S. D., Ledbetter, N. M., Warren, D. A., & Clark, G. A. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/2/026019 · Cited by 37
“Further, a number of the implanted electrodes selectively activate independent groups of motor units in a targeted muscle, allowing recruitment of muscle forces by more biomimetic, physiologically based mechanisms that can generate controllable muscle forces [20, 21].”
BackgroundSelf-citationMuscle‐selective block using intrafascicular high‐frequency alternating current
Dowden, B. R., Wark, H. A. C., & Normann, R. A. (2010) · Muscle & Nerve · doi:10.1002/mus.21678 · Cited by 30
Self-citationNataraj, R., Audu, M. L., & Triolo, R. J. (2017) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2017.01.023 · Cited by 26
Davids, M., Guérin, B., Klein, V., Schmelz, M., Schad, L. R., & Wald, L. L. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab52bd · Cited by 22
Bourbeau, D. J., Hokanson, J., Rubin, J. E., & Weber, D. J. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/5/056009 · Cited by 28
Resistance exercise performance variability at submaximal intensities in older and younger adults
Grosicki, G. J., Miller, M. E., & Marsh, A. P. (2014) · Clinical Interventions in Aging · doi:10.2147/cia.s55719 · Cited by 28
Selective and Graded Recruitment of Cat Hamstring Muscles With Intrafascicular Stimulation
Dowden, B. R., Wilder, A. M., Hiatt, S. D., Normann, R. A., Brown, N. A. T., & Clark, G. A. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.2011988 · Cited by 22
Self-citationA Flat Interface Nerve Electrode With Integrated Multiplexer
Lertmanorat, Z., Montague, F. W., & Durand, D. M. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.2009307 · Cited by 18
Biarticular hip extensor and knee flexor muscle moment arms of the feline hindlimb
MacFadden, L. N., & Brown, N. A. T. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.05.021 · Cited by 19
Normann, R. A., McDonnall, D., Clark, G. A., Stein, R. B., & Branner, A. (2006) · International Joint Conference on Neural Networks (IJCNN) · doi:10.1109/ijcnn.2005.1556422 · Cited by 15
Self-citationTemporal Modulation of the Response of Sensory Fibers to Paired-Pulse Stimulation
Brunton, E., Silveira, C. R. A., Rosenberg, J. V., Schiefer, M. A., Riddell, J. S., & Nazarpour, K. (2019) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2019.2935813 · Cited by 13
Interleaved neuromuscular electrical stimulation: Motor unit recruitment overlap
Wiest, M. J., Bergquist, A. J., Schimidt, H. L., Jones, K. E., & Collins, D. F. (2016) · Muscle & Nerve · doi:10.1002/mus.25249 · Cited by 15
Dowden, B. R., Frankel, M. A., Normann, R. A., & Clark, G. A. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/1/016006 · Cited by 11
Self-citationFinite Element Analysis of a Floating Microstimulator
Şahin, M., & Ur-Rahman, S. S. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.897027 · Cited by 11
Improved long‐term recording of nerve signal by modified intrafascicular electrodes in rabbits
Jia, X., Zhen, G., Püttgen, H. A., Zhang, J., & Chen, T. (2008) · Microsurgery · doi:10.1002/micr.20475 · Cited by 10
Eladly, A., del Valle, J., Minguillón, J., Mercadal, B., Becerra-Fajardo, L., Navarro, X., & Ivorra, A. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/aba99e · Cited by 9
MacFadden, L. N., & Brown, N. A. T. (2010) · Journal of Biomechanical Engineering · doi:10.1115/1.4001680 · Cited by 7
Control of Skeletal Muscle Force with Currents Injected Via an Intrafascicular, Microelectrode Array
Normann, R. A., McDonnall, D., & Clark, G. A. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2005.1616282 · Cited by 8
Self-citationThomas, W., Zuniga, S. A., Sondh, I., Leber, M., Solzbacher, F., Lenarz, T., Lim, H. H., Warren, D. J., Rieth, L. W., & Adams, M. E. (2024) · Frontiers in Neuroscience · doi:10.3389/fnins.2024.1308663 · Cited by 8
Sandercock, T. G. (2006) · Journal of Neurophysiology · doi:10.1152/jn.01304.2005 · Cited by 7
Functional Electrical Stimulation
Venkatasubramanian, G., Jung, R., & Sweeney, J. (2006) · Wiley eBooks · doi:10.1002/0471732877.emd119 · Cited by 8
The Role of Biomaterials in Stimulating Bioelectrodes
Peckham, P. H., Ackermann, D. M., & Moss, C. W. (2012) · Elsevier eBooks · doi:10.1016/b978-0-08-087780-8.00084-x · Cited by 8
Schiefer, M. A., Tyler, D. J., & Triolo, R. J. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6091011 · Cited by 7
Fisher, L. E., Anderson, J. S., Tyler, D. J., & Triolo, R. J. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6090831 · Cited by 3
Improving Neuroprosthesis-Assisted Standing with Nerve-Based Stimulating Electrodes
Fisher, L. E. (2012) · OhioLink ETD Center (Ohio Library and Information Network) · Cited by 5
Sinkjær, T., Yoshida, K., Jensen, W., & Schnabel, V. (2006) · Wiley eBooks · doi:10.1002/0471732877.emd098 · Cited by 3
Cavalcanti, L. M., Thomas, W., Warren, D. J., & Mathews, V. J. (2025) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2025.3530924 · Cited by 3
VENTRAL ROOT OR DORSAL ROOT GANGLION MICROSTIMULATION TO EVOKE HINDLIMB MOTOR RESPONSES
Bourbeau, D. J. (2011) · D-Scholarship@Pitt (University of Pittsburgh) · Cited by 2
Ainsley, E. N., Barss, T. S., & Collins, D. F. (2020) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/apnm-2019-0851 · Cited by 5
Intrafascicular multielectrode stimulation strategies for neuroprosthetic applications
Dowden, B. R. (2012) · J. Willard Marriott Library · doi:10.26053/0h-pjk4-w600 · Cited by 1
Progress in Peripheral Neural Interfaces
Qiao, S., Mauser, K. A., & Yoshida, K. (2013) · Wiley eBooks · doi:10.1002/9781118628522.ch4 · Cited by 1
Regenerative Peripheral Neurointerfacing Of Upper Extremity Prostheses
Garde, K. (2008) · UTA ResearchCommons (University of Texas Arlington)
Hokanson, J. (2014) · D-Scholarship@Pitt (University of Pittsburgh) · Cited by 1
Ainsley, E. N. (2018) · ERA: Education and Research Archive (University of Alberta) · doi:10.7939/r32n5000x
Chronic Nerve Interfacing Utilizing Graft-Embedded Regenerative Macro-Sieve Electrodes
Nishtala, A. (2018) · Open Scholarship Institutional Repository (Washington University in St. Louis) · doi:10.7936/k71n80j9
Metadata
- Authors
- McDonnall, D., Clark, G. A., & Normann, R. A.
- Affiliations
- University of Utah (US)
- ORCID
- Clark, Gregory A
- Venue
- Canadian Journal of Physiology and Pharmacology
- Publisher
- Canadian Science Publishing
- Published
- 2004-07-01
- Volume
- 82
- Issue
- 8-9
- Pages
- 599-609
- ISSN
- 0008-4212 (ISSN-L)
- 1205-7541
- OpenAlex
- W1967684732
- Semantic Scholar
- 88e0f3c1269ae660fb55df8fb75aed9cd67d5242
- Cited by
- 53
- References
- 29
- Citations by year
- 2025: 1 · 2024: 1 · 2020: 2 · 2019: 3 · 2018: 3 · 2017: 1 · 2016: 2 · 2015: 1 · 2014: 2 · 2013: 3 · 2012: 7
- FWCI
- 1.17
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.nrcresearchpress.com/page/about/CorporateTextAndDataMining (tdm)
- Locations
- Canadian Journal of Physiology and Pharmacology (publishedVersion)
- PubMed (publishedVersion)
- Funders
- University of Utah
- National Institutes of Health
- National Institute of Neurological Disorders and Stroke (1-R01-NS-39677, R01NS039677)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Life Sciences › Neuroscience › Neurology › Vagus Nerve Stimulation Research
- Keywords
- motor unit recruitment, peripheral nerve stimulation, sciatic nerve, triceps surae, gastrocnemius, soleus muscle, muscle force production
- MeSH terms
- Animals, Cats, Electric Stimulation, Electrodes, Sciatic Nerve, Muscle, Skeletal, Muscle Fibers, Skeletal
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.