Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 2,690

The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.

Dialysis Dose and Intradialytic Hypotension: Results from the HEMO Study

Open access
Mc Causland, Finnian R., Brunelli, Steven M., Waikar, Sushrut S. · 2013 · American Journal of Nephrology

Abstract

Background: Intradialytic hypotension (IDH) is common and is associated with increased morbidity and mortality in chronic hemodialysis patients. A higher dialysis ‘dose' may generate transient intradialytic osmotic gradients, predisposing to intracellular fluid shifts and resulting in hypotension. Study Design: We performed a post hoc analysis of the HEMO study, a multicenter trial that randomized chronic hemodialysis patients to high versus standard Kt/V and higher versus lower membrane flux. In order to achieve dose targets, per protocol, adjustments were made in membrane efficiency, blood flow or dialysate flow before changing session length. Detailed hemodynamic and urea kinetic modeling data were abstracted from 1,825 individuals. The primary outcome was the occurrence of hypotensive events necessitating clinical intervention (saline infusion, lowering of ultrafiltration rate or reduced blood flow). Results: Intradialytic hypotensive events occurred more frequently in the higher-Kt/V group (18.3 vs. 16.8%; p < 0.001). Participants randomized to higher-target Kt/V had a greater adjusted risk of IDH than those randomized to standard Kt/V [odds ratio (OR) 1.12; 95% confidence interval (CI) 1.01-1.25]. Higher vs. lower dialyzer mass transfer-area coefficient for urea and rate of urea removal were associated with greater adjusted odds of IDH (OR 1.15; 95% CI 1.04-1.27 and OR 1.05; 95% CI 1.04-1.06 per mg/dl/h, respectively). Conclusions: Higher dialysis dose, at relatively constrained treatment times, may associate with an increased risk of IDH. These findings support the possibility that rapidity of intradialytic reductions in plasma osmolality may play an important role in mediating hemodynamic instability during dialysis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1159/000355958

Cites

20 of 20 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 20 references

Research works printed but not linked: 21

  1. 10.1159/000076745 · doi:10.1159/000076745
  2. 10.1681/ASN.2007091006 · doi:10.1681/asn.2007091006
  3. 10.1046/j.1523-1755.2001.0590031175.x · doi:10.1046/j.1523-1755.2001.0590031175.x
  4. 10.1111/j.1542-4758.2009.00365.x · doi:10.1111/j.1542-4758.2009.00365.x
  5. 10.1046/j.1523-1755.1999.00737.x · doi:10.1046/j.1523-1755.1999.00737.x
  6. 10.1038/ki.1992.339 · doi:10.1038/ki.1992.339
  7. 10.1681/ASN.2004070581 · doi:10.1681/asn.2004070581
  8. 10.7326/0003-4819-104-3-358 · doi:10.7326/0003-4819-104-3-358
  9. 10.1038/ki.1994.199 · doi:10.1038/ki.1994.199
  10. 10.1093/ndt/gfg590 · doi:10.1093/ndt/gfg590
  11. 10.1081/JDI-100107360 · doi:10.1081/jdi-100107360
  12. 10.1093/ndt/11.supp8.10 · doi:10.1093/ndt/11.supp8.10
  13. 10.1111/j.1525-139X.2008.00474.x · DOI
  14. 10.1038/ki.1980.161 · doi:10.1038/ki.1980.161
  15. 10.7326/0003-4819-86-5-554 · doi:10.7326/0003-4819-86-5-554
  16. 10.1038/ki.1973.51 · doi:10.1038/ki.1973.51
  17. 10.1093/ndt/gfh102 · doi:10.1093/ndt/gfh102
  18. 10.1038/ki.1973.51 · doi:10.1038/ki.1973.51
  19. 10.1093/ndt/gfs091 · doi:10.1093/ndt/gfs091
  20. 10.1053/j.ajkd.2008.03.024 · doi:10.1053/j.ajkd.2008.03.024
  21. 10.1159/000341273 · doi:10.1159/000341273

Cited by

Metadata

Authors
Mc Causland, F. R., Brunelli, S. M., & Waikar, S. S.
Venue
American Journal of Nephrology
Publisher
S. Karger AG
Published
2013
Volume
38
Issue
5
Pages
388-396
ISSN
  • 0250-8095 (ISSN-L)
  • 1421-9670
OpenAlex
W2030235211
Cited by
2,690
References
20
FWCI
135.01
Type
journal article
Language
en
Open access
bronze
Licence

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.