A Review of the Biocompatibility of Implantable Devices: Current Challenges to Overcome Foreign Body Response
Open accessThe DOI matches its Crossref record; 134 of the 134 references it cites were found in a registry or an index.
Abstract
In recent years, a variety of devices (drug-eluting stents, artificial organs, biosensors, catheters, scaffolds for tissue engineering, heart valves, etc.) have been developed for implantation into patients. However, when such devices are implanted into the body, the body can react to these in a number of different ways. These reactions can result in an unexpected risk for patients. Therefore, it is important to assess and optimize the biocompatibility of implantable devices. To date, numerous strategies have been investigated to overcome body reactions induced by the implantation of devices. This review focuses on the foreign body response and the approaches that have been taken to overcome this. The biological response following device implantation and the methods for biocompatibility evaluation are summarized. Then the risks of implantable devices and the challenges to overcome these problems are introduced. Specifically, the challenges used to overcome the functional loss of glucose sensors, restenosis after stent implantation, and calcification induced by implantable devices are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Foreign body reaction to biomaterials
Anderson, J. M., Rodriguez, A., & Chang, D. T. (2008) · Seminars in Immunology · doi:10.1016/j.smim.2007.11.004 · Cited by 5,138
(2013) · doi:10.1016/c2009-0-02433-7 · Cited by 5,127
Biodegradation and biocompatibility of PLA and PLGA microspheres
Anderson, J. M., & Shive, M. S. (1997) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(97)00048-3 · Cited by 2,617
Bone Tissue Engineering: State of the Art and Future Trends
Salgado, A. J., Coutinho, O. P., & Reis, R. L. (2004) · Macromolecular Bioscience · doi:10.1002/mabi.200400026 · Cited by 1,681
Implantable applications of chitin and chitosan
Khor, E., & Lim, L. Y. (2003) · Biomaterials · doi:10.1016/s0142-9612(03)00026-7 · Cited by 1,672
Safety and Efficacy of Sirolimus- and Paclitaxel-Eluting Coronary Stents
Stone, G. W., Moses, J. W., Ellis, S. G., Schofer, J., Dawkins, K. D., Morice, M.-C., Colombo, A., Schampaert, E., Grube, E., Kirtane, A. J., et al. (2007) · New England Journal of Medicine · doi:10.1056/nejmoa067193 · Cited by 1,631
Biomaterials: Where We Have Been and Where We Are Going
Ratner, B. D., & Bryant, S. J. (2004) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.6.040803.140027 · Cited by 1,507
Athanasiou, K. A., Niederauer, G. G., & Agrawal, C. M. (1996) · Biomaterials · doi:10.1016/0142-9612(96)85754-1 · Cited by 1,497
Biological Responses to Materials
Anderson, J. M. (2001) · Annual Review of Materials Research · doi:10.1146/annurev.matsci.31.1.81 · Cited by 1,465
Hassan, C. M., & Peppas, N. A. (2007) · Advances in Polymer Science · doi:10.1007/3-540-46414-x_2 · Cited by 1,356
Cited by
Yang, J. C., Mun, J., Kwon, S. Y., Park, S., Bao, Z., & Park, S. (2019) · Advanced Materials · doi:10.1002/adma.201904765 · Cited by 1,641
Translational Applications of Hydrogels
Correa, S., Grosskopf, A. K., Lopez Hernandez, H., Chan, D., Yu, A. C., Stapleton, L. M., & Appel, E. A. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c01177 · Cited by 1,143
“Green” electronics: biodegradable and biocompatible materials and devices for sustainable future
Irimia-Vladu, M. (2014) · Chem. Soc. Rev. · doi:10.1039/c3cs60235d · Cited by 1,044
Degradation and stabilization of polyurethane elastomers
Xie, F., Zhang, T., Bryant, P., Kurusingal, V., Colwell, J. M., & Laycock, B. (2019) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2018.12.003 · Cited by 722
Biocompatibility and safety of PLA and its copolymers
Ramot, Y., Haim-Zada, M., Domb, A. J., & Nyska, A. (2016) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2016.03.012 · Cited by 576
Extracellular matrix-based biomaterial scaffolds and the host response
Aamodt, J. M., & Grainger, D. W. (2016) · Biomaterials · doi:10.1016/j.biomaterials.2016.02.003 · Cited by 509
Multifunctional “Hydrogel Skins” on Diverse Polymers with Arbitrary Shapes
Yu, Y., Yuk, H., Parada, G. A., Wu, Y., Liu, X., Nabzdyk, C. S., Youcef‐Toumi, K., Zang, J., & Zhao, X. (2019) · Advanced Materials · doi:10.1002/adma.201807101 · Cited by 482
Artificial intelligence biosensors: Challenges and prospects
Jin, X., Liu, C., Xu, T., Su, L., & Zhang, X. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112412 · Cited by 399
Biological responses to physicochemical properties of biomaterial surface
Rahmati, M., Silva, E. A., Reseland, J. E., A. Heyward, C., & Haugen, H. J. (2020) · Chemical Society Reviews · doi:10.1039/d0cs00103a · Cited by 391
Emerging synergy between nanotechnology and implantable biosensors: A review
Vaddiraju, S., Tomazos, I., Burgess, D. J., Jain, F. C., & Papadimitrakopoulos, F. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2009.12.001 · Cited by 368
Self-citationDevelopment of Implantable Medical Devices: From an Engineering Perspective
Joung, Y.-H. (2013) · International Neurourology Journal · doi:10.5213/inj.2013.17.3.98 · Cited by 367
“Then, immune and inflammatory cells, such as monocytes, leukocytes, and platelets, react to defend the body from the external specimen [37-39].”
BackgroundBernard, M., Jubeli, E., Pungente, M. D., & Yagoubi, N. (2018) · Biomaterials Science · doi:10.1039/c8bm00518d · Cited by 350
Long-term in vivo glucose monitoring using fluorescent hydrogel fibers
Heo, Y. J., Shibata, H., Okitsu, T., Kawanishi, T., & Takeuchi, S. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1104954108 · Cited by 310
Strategies for body-conformable electronics
Liu, S., Rao, Y., Jang, H., Tan, P., & Lu, N. (2022) · Matter · doi:10.1016/j.matt.2022.02.006 · Cited by 306
Zhang, D., Chen, Q., Shi, C., Chen, M., Ma, K., Wan, J., & Liu, R. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202007226 · Cited by 303
Biodegradable electronics: cornerstone for sustainable electronics and transient applications
Tan, M. J., Owh, C., Chee, P. L., Kyaw, A. K. K., Kai, D., & Loh, X. J. (2016) · Journal of Materials Chemistry C · doi:10.1039/c6tc00678g · Cited by 288
Technologies for Continuous Glucose Monitoring: Current Problems and Future Promises
Vaddiraju, S., Burgess, D. J., Tomazos, I., Jain, F. C., & Papadimitrakopoulos, F. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400632 · Cited by 285
Self-citationFang, H., Yu, K. J., Gloschat, C., Yang, Z., Song, E., Chiang, C.-H., Zhao, J., Won, S. M., Xu, S., Trumpis, M., et al. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-017-0038 · Cited by 278
Nonspecific Binding—Fundamental Concepts and Consequences for Biosensing Applications
Frutiger, A., Tanno, A., Hwu, S., Tiefenauer, R. F., Vörös, J., & Nakatsuka, N. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00044 · Cited by 278
Biocompatibility of Subcutaneously Implanted Plant-Derived Cellulose Biomaterials
Modulevsky, D. J., Cuerrier, C. M., & Pelling, A. E. (2016) · PLOS ONE · doi:10.1371/journal.pone.0157894 · Cited by 254
Xie, X., Doloff, J. C., Yesilyurt, V., Sadraei, A., McGarrigle, J. J., Omami, M., Veiseh, O., Farah, S., Isa, D., Ghani, S., et al. (2018) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0273-3 · Cited by 235
Biocompatibility evaluation of tissue-engineered decellularized scaffolds for biomedical application
Hussein, K. H., Park, K.-M., Kang, K.-S., & Woo, H.-M. (2016) · Materials Science and Engineering: C · doi:10.1016/j.msec.2016.05.068 · Cited by 218
Short-Term and Long-Term Effects of Orthopedic Biodegradable Implants
Amini, A. R., Wallace, J. S., & Nukavarapu, S. P. (2011) · Journal of Long-Term Effects of Medical Implants · doi:10.1615/jlongtermeffmedimplants.v21.i2.10 · Cited by 181
Biocompatibility of Resorbable Polymers: A Historical Perspective and Framework for the Future
Pappalardo, D., Mathisen, T., & Finne-Wistrand, A. (2019) · Biomacromolecules · doi:10.1021/acs.biomac.9b00159 · Cited by 177
Polymer integration for packaging of implantable sensors
Qin, Y., Howlader, M. M. R., Deen, M. J., Haddara, Y. M., & Selvaganapathy, P. R. (2014) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2014.05.063 · Cited by 163
Helton, K. L., Ratner, B. D., & Wisniewski, N. A. (2011) · Journal of Diabetes Science and Technology · doi:10.1177/193229681100500317 · Cited by 125
Wireless communication with implanted medical devices using the conductive properties of the body
Ferguson, J. E., & Redish, A. D. (2011) · Expert Review of Medical Devices · doi:10.1586/erd.11.16 · Cited by 112
Wang, R. M., Johnson, T. D., He, J., Rong, Z., Wong, M., Nigam, V., Behfar, A., Xu, Y., & Christman, K. L. (2017) · Biomaterials · doi:10.1016/j.biomaterials.2017.03.016 · Cited by 90
“This combined with our incomplete understanding of the human immune system has led to the removal of several well characterized materials from the market [14,15].”
BackgroundRamot, Y., Rotkopf, S., Gabai, R. M., Zorde Khvalevsky, E., Muravnik, S., Marzoli, G. A., Domb, A. J., Shemi, A., & Nyska, A. (2016) · Toxicologic Pathology · doi:10.1177/0192623316645860 · Cited by 64
“The capsule formation typically composed of a relatively thin mature fibrotic tissue, which was of comparable thickness in all these groups, as well as without any evidence of chronic active inflammation, necrosis, and/or mineralization, which may suggest potential adverse effects (Northup 1999; Nyska et al. 2014; Onu…”
BackgroundDevelopment of Cationic Polymer Coatings to Regulate Foreign‐Body Responses
Ma, M., Liu, W. F., Hill, P. S., Bratlie, K. M., Siegwart, D. J., Chin, J., Park, M., Guerreiro, J., & Anderson, D. G. (2011) · Advanced Materials · doi:10.1002/adma.201100513 · Cited by 59
Modification of Biomaterials with a Self‐Protein Inhibits the Macrophage Response
Kim, Y. K., Que, R., Wang, S., & Liu, W. F. (2014) · Advanced Healthcare Materials · doi:10.1002/adhm.201300532 · Cited by 56
Ramot, Y., Nyska, A., Markovitz, E., Dekel, A., Klaiman, G., Zada, M. H., Domb, A. J., & Maronpot, R. R. (2015) · Toxicologic Pathology · doi:10.1177/0192623315600275 · Cited by 55
Luo, L., He, Y., Chang, Q., Xie, G., Zhan, W., Wang, X., Zhou, T., Xing, M., & Lu, F. (2016) · International Journal of Nanomedicine · doi:10.2147/ijn.s114295 · Cited by 41
Printable microscale interfaces for long-term peripheral nerve mapping and precision control
Otchy, T. M., Michas, C., Lee, B., Gopalan, K., Nerurkar, V., Gleick, J., Semu, D., Darkwa, L., Holinski, B. J., Chew, D. J., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-18032-4 · Cited by 35
Metadata
- Authors
- Onuki, Y., Bhardwaj, U., Papadimitrakopoulos, F., & Burgess, D. J.
- Venue
- Journal of Diabetes Science and Technology
- Publisher
- SAGE Publications
- Published
- 2008-11
- Volume
- 2
- Issue
- 6
- Pages
- 1003-1015
- ISSN
- 1932-2968 (ISSN-L)
- OpenAlex
- W2146749893
- Cited by
- 418
- References
- 134
- Type
- conference abstract
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.