TEER Measurement Techniques for In Vitro Barrier Model Systems
Open accessThe DOI matches its Crossref record; 126 of the 126 references it cites were found in a registry or an index.
Abstract
Transepithelial/transendothelial electrical resistance (TEER) is a widely accepted quantitative technique to measure the integrity of tight junction dynamics in cell culture models of endothelial and epithelial monolayers. TEER values are strong indicators of the integrity of the cellular barriers before they are evaluated for transport of drugs or chemicals. TEER measurements can be performed in real time without cell damage and generally are based on measuring ohmic resistance or measuring impedance across a wide spectrum of frequencies. The measurements for various cell types have been reported with commercially available measurement systems and also with custom-built microfluidic implementations. Some of the barrier models that have been widely characterized using TEER include the blood-brain barrier (BBB), gastrointestinal (GI) tract, and pulmonary models. Variations in these values can arise due to factors such as temperature, medium formulation, and passage number of cells. The aim of this article is to review the different TEER measurement techniques and analyze their strengths and weaknesses, determine the significance of TEER in drug toxicity studies, examine the various in vitro models and microfluidic organs-on-chips implementations using TEER measurements in some widely studied barrier models (BBB, GI tract, and pulmonary), and discuss the various factors that can affect TEER measurements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Impedance Spectroscopy: Theory, Experiment, and Applications
(2005) · Wiley eBooks · doi:10.1002/0471716243 · Cited by 5,322
Reconstituting organ-level lung functions on a chip
Huh, D., Matthews, B. D., Mammoto, A., Montoya-Zavala, M., Hsin, H. Y., & Ingber, D. E. (2010) · Science · doi:10.1126/science.1188302 · Cited by 4,250 · cited 1×
“ROS levels.(85) To date, none of the microfluidic systems built to measure pulmonary function have electrodes embedded to obtain real-time TEER measurements.”
BackgroundKim, H. J., Huh, D., Hamilton, G., & Ingber, D. E. (2012) · Lab on a Chip · doi:10.1039/c2lc40074j · Cited by 1,734 · cited 1×
“Those microfabricated systems that are designed for TEER measurements, however, can offer TEER data in addition to permeability coefficients.(78) With the system developed by Kim et al.”
Artursson, P., Palm, K., & Luthman, K. (2001) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(00)00128-9 · Cited by 1,543
Sambuy, Y., De Angelis, I., Ranaldi, G., Scarino, M. L., Stammati, A., & Zucco, F. (2005) · Cell Biology and Toxicology · doi:10.1007/s10565-005-0085-6 · Cited by 1,488
Yee, S. (1997) · Pharmaceutical Research · doi:10.1023/a:1012102522787 · Cited by 1,030
Controlled microfluidic interfaces
Atencia, J., & Beebe, D. J. (2005) · Nature · doi:10.1038/nature04163 · Cited by 1,006
Derivation of blood-brain barrier endothelial cells from human pluripotent stem cells
Lippmann, E. S., Azarin, S. M., Kay, J. E., Nessler, R. A., Wilson, H. K., Al-Ahmad, A., Palecek, S. P., & Shusta, E. V. (2012) · Nature Biotechnology · doi:10.1038/nbt.2247 · Cited by 800
Electrical resistance across the blood-brain barrier in anaesthetized rats: a developmental study.
Butt, A. M., Jones, H. C., & Abbott, N. J. (1990) · The Journal of Physiology · doi:10.1113/jphysiol.1990.sp018243 · Cited by 775
Characterization of a microfluidic in vitro model of the blood-brain barrier (μBBB)
Booth, R., & Kim, H. (2012) · Lab on a Chip · doi:10.1039/c2lc40094d · Cited by 739
Cited by
A guide to the organ-on-a-chip
Leung, C. M., de Haan, P., Ronaldson-Bouchard, K., Kim, G.-A., Ko, J., Rho, H. S., Chen, Z., Habibovic, P., Jeon, N. L., Takayama, S., et al. (2022) · Nature Reviews Methods Primers · doi:10.1038/s43586-022-00118-6 · Cited by 1,116
Self-citationHelms, H. C., Abbott, N. J., Burek, M., Cecchelli, R., Couraud, P.-O., Deli, M. A., Förster, C., Galla, H. J., Romero, I. A., Shusta, E. V., et al. (2016) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1177/0271678x16630991 · Cited by 843
“TEER obtained by separate groups in separate studies may differ somewhat, not only because of differences in actual junctional tightness but also because of differences in measuring equipment (chopstick electrodes, cup electrodes, impedance measurements), temperature, and handling of the cells during measurements.(52)…”
ResultPark, T.-E., Mustafaoglu, N., Herland, A., Hasselkus, R., Mannix, R., FitzGerald, E. A., Prantil-Baun, R., Watters, A., Henry, O., Benz, M., et al. (2019) · Nature Communications · doi:10.1038/s41467-019-10588-0 · Cited by 594
Wang, Y. I., Abaci, H. E., & Shuler, M. L. (2017) · Biotechnology and Bioengineering · doi:10.1002/bit.26045 · Cited by 563
Self-citationBacteriocins as a new generation of antimicrobials: toxicity aspects and regulations
Soltani, S., Hammami, R., Cotter, P. D., Rebuffat, S., Said, L. B., Gaudreau, H., Bédard, F., Biron, E., Drider, D., & Fliss, I. (2021) · FEMS Microbiology Reviews · doi:10.1093/femsre/fuaa039 · Cited by 544
Henry, O. Y. F., Villenave, R., Cronce, M. J., Leineweber, W. D., Benz, M. A., & Ingber, D. E. (2017) · Lab on a Chip · doi:10.1039/c7lc00155j · Cited by 482
Fetal Bovine Serum (FBS): past ‐ present ‐ future
van der Valk, J. (2018) · ALTEX · doi:10.14573/altex.1705101 · Cited by 481
“The generation of transepithelial electrical resistance (TEER) can be determined as an overall parameter for the integrity of the cultured epithelium (Srinivasan et al., 2015).”
BackgroundGeirnaert, A., Calatayud, M., Grootaert, C., Laukens, D., Devriese, S., Smagghe, G., De Vos, M., Boon, N., & Van de Wiele, T. (2017) · Scientific Reports · doi:10.1038/s41598-017-11734-8 · Cited by 451
Development of Polymeric Nanoparticles for Blood–Brain Barrier Transfer—Strategies and Challenges
Zhang, W., Mehta, A., Tong, Z., Esser, L., & Voelcker, N. H. (2021) · Advanced Science · doi:10.1002/advs.202003937 · Cited by 430
Neuronal regulation of the blood–brain barrier and neurovascular coupling
Kaplan, L., Chow, B. W., & Gu, C. (2020) · Nature Reviews Neuroscience · doi:10.1038/s41583-020-0322-2 · Cited by 430
Chitosan Nanoparticles at the Biological Interface: Implications for Drug Delivery
Aibani, N., Rai, R., Patel, P., Cuddihy, G., & Wasan, E. K. (2021) · Pharmaceutics · doi:10.3390/pharmaceutics13101686 · Cited by 419
Microfluidic organ-on-chip technology for blood-brain barrier research
van der Helm, M. W., van der Meer, A. D., Eijkel, J. C. T., van den Berg, A., & Segerink, L. I. (2016) · Tissue Barriers · doi:10.1080/21688370.2016.1142493 · Cited by 333
Organ-on-a-chip platforms: a convergence of advanced materials, cells, and microscale technologies
Ahadian, S., Civitarese, R., Bannerman, D., Mohammadi, M. H., Lu, R., Wang, E., Davenport‐Huyer, L., Lai, B., Zhang, B., Zhao, Y., et al. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201700506 · Cited by 315
Cong, X., & Kong, W. (2020) · Cellular Signalling · doi:10.1016/j.cellsig.2019.109485 · Cited by 302
Probiotics, Prebiotics, and Phytogenic Substances for Optimizing Gut Health in Poultry
Shehata, A. A., Yalçın, S., Latorre, J. D., Basiouni, S., Attia, Y. A., Abd El-Wahab, A., Visscher, C., El-Seedi, H. R., Huber, C., Hafez, H. M., et al. (2022) · Microorganisms · doi:10.3390/microorganisms10020395 · Cited by 285
Blanchard, J. W., Bula, M., Davila-Velderrain, J., Akay, L. A., Zhu, L., Frank, A., Victor, M. B., Bonner, J. M., Mathys, H., Lin, Y.-T., et al. (2020) · Nature Medicine · doi:10.1038/s41591-020-0886-4 · Cited by 283
Maoz, B. M., Herland, A., Henry, O. Y. F., Leineweber, W. D., Yadid, M., Doyle, J., Mannix, R., Kujala, V. J., FitzGerald, E. A., Parker, K. K., et al. (2017) · Lab on a Chip · doi:10.1039/c7lc00412e · Cited by 266
Engineered human blood–brain barrier microfluidic model for vascular permeability analyses
Hajal, C., Offeddu, G. S., Shin, Y., Zhang, S., Morozova, O., Hickman, D., Knutson, C. G., & Kamm, R. D. (2022) · Nature Protocols · doi:10.1038/s41596-021-00635-w · Cited by 257
A Novel Transwell Blood Brain Barrier Model Using Primary Human Cells
Stone, N. L., England, T. J., & O’Sullivan, S. E. (2019) · Frontiers in Cellular Neuroscience · doi:10.3389/fncel.2019.00230 · Cited by 251
Intestinal barrier permeability: the influence of gut microbiota, nutrition, and exercise
Dmytriv, T. R., Storey, K. B., & Lushchak, V. I. (2024) · Frontiers in Physiology · doi:10.3389/fphys.2024.1380713 · Cited by 246
Gut-on-a-chip: Current progress and future opportunities
Ashammakhi, N., Nasiri, R., Barros, N. R. D., Tebon, P., Thakor, J., Goudie, M., Shamloo, A., Martin, M. G., & Khademhosseini, A. (2020) · Biomaterials · doi:10.1016/j.biomaterials.2020.120196 · Cited by 235
Pentacyclic Triterpene Bioavailability: An Overview of In Vitro and In Vivo Studies
J. C. Furtado, N., Pirson, L., Edelberg, H., M. Miranda, L., Loira-Pastoriza, C., Preat, V., Larondelle, Y., & André, C. (2017) · Molecules · doi:10.3390/molecules22030400 · Cited by 232
“The increased permeability occurred with a concomitant reduction in the transepithelial electrical resistance (TEER), which is a widely-accepted quantitative technique to measure the integrity of the cell monolayer grown on membrane inserts in cell culture models [66].”
BackgroundFedi, A., Vitale, C., Ponschin, G., Ayehunie, S., Fato, M., & Scaglione, S. (2021) · Journal of Controlled Release · doi:10.1016/j.jconrel.2021.05.028 · Cited by 229
Lu, T. M., Houghton, S., Magdeldin, T., Durán, J. G. B., Minotti, A. P., Snead, A., Sproul, A., Nguyen, D.-H. T., Xiang, J., Fine, H. A., et al. (2021) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2016950118 · Cited by 224
“Using TEER measurement as a proxy for functional BBB tight junctions has some limitations, since it can only measure the paracellular, as opposed to transcellular, permeability.”
InfluentialTrapecar, M., Communal, C., Velazquez, J., Maass, C. A., Huang, Y.-J., Schneider, K., Wright, C. W., Butty, V., Eng, G., Yilmaz, O., et al. (2020) · Cell Systems · doi:10.1016/j.cels.2020.02.008 · Cited by 218
Microfabricated blood vessels for modeling the vascular transport barrier
Polacheck, W. J., Kutys, M. L., Tefft, J. B., & Chen, C. S. (2019) · Nature Protocols · doi:10.1038/s41596-019-0144-8 · Cited by 215
Functional 3D Printing for Microfluidic Chips
Weisgrab, G., Ovsianikov, A., & Costa, P. F. (2019) · Advanced Materials Technologies · doi:10.1002/admt.201900275 · Cited by 206
A lung/liver-on-a-chip platform for acute and chronic toxicity studies
Bovard, D., Sandoz, A., Luettich, K., Frentzel, S., Iskandar, A., Marescotti, D., Trivedi, K., Guedj, E., Dutertre, Q., Peitsch, M. C., et al. (2018) · Lab on a Chip · doi:10.1039/c8lc01029c · Cited by 195
LightBBB: computational prediction model of blood–brain-barrier penetration based on LightGBM
Shaker, B., Yu, M.-S., Song, J. S., Ahn, S., Ryu, J. Y., Oh, K.-S., & Na, D. (2021) · Bioinformatics · doi:10.1093/bioinformatics/btaa918 · Cited by 192
In-vitro blood–brain barrier modeling: A review of modern and fast-advancing technologies
Sivandzade, F., & Cucullo, L. (2018) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1177/0271678x18788769 · Cited by 189
Chitosan-coated mesoporous MIL-100(Fe) nanoparticles as improved bio-compatible oral nanocarriers
Hidalgo, T., Giménez-Marqués, M., Bellido, E., Avila, J., Asensio, M. C., Salles, F., Lozano, M. V., Guillevic, M., Simón-Vázquez, R., González-Fernández, A., et al. (2017) · Scientific Reports · doi:10.1038/srep43099 · Cited by 173
Multiorgan Microphysiological Systems for Drug Development: Strategies, Advances, and Challenges
Wang, Y. I., Carmona, C., Hickman, J. J., & Shuler, M. L. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201701000 · Cited by 167
Self-citationvan der Helm, M. W., Henry, O. Y. F., Bein, A., Hamkins-Indik, T., Cronce, M. J., Leineweber, W. D., Odijk, M., van der Meer, A. D., Eijkel, J. C. T., Ingber, D. E., et al. (2019) · Lab on a Chip · doi:10.1039/c8lc00129d · Cited by 161
Faal, T., Phan, D. T. T., Davtyan, H., Scarfone, V. M., Varady, E., Blurton-Jones, M., Hughes, C. C. W., & Inlay, M. A. (2019) · Stem Cell Reports · doi:10.1016/j.stemcr.2019.01.005 · Cited by 124
“Effects of Pericytes on Barrier Properties of ECs Electrical resistance across an endothelial layer is a crucial physiological property that can be used to examine the strength of various barrier systems (Srinivasan et al., 2015).”
BackgroundAstrocytic VEGFA : An essential mediator in blood–brain‐barrier disruption in Parkinson's disease
Lan, G., Wang, P., Chan, R. B., Liu, Z., Yu, Z., Liu, X., Yang, Y., & Zhang, J. (2022) · Glia · doi:10.1002/glia.24109 · Cited by 122
Fowler, S., Chen, W. L. K., Duignan, D. B., Gupta, A., Hariparsad, N., Kenny, J. R., Lai, W. G., Liras, J., Phillips, J. A., & Gan, J. (2020) · Lab on a Chip · doi:10.1039/c9lc00857h · Cited by 109
Wang, X., Sun, Q., & Pei, J. (2018) · Micromachines · doi:10.3390/mi9100493 · Cited by 106
“In addition to permeability measurement, transendothelial electrical resistance (TEER) is a widely accepted method to quantify vascular integrity by characterizing electric impedance across the endothelium (Figure 5(Cii)) [93,109].”
MethodYeste, J., García-Ramírez, M., Illa, X., Guimerà, A., Hernández, C., Simó, R., & Villa, R. (2018) · Lab on a Chip · doi:10.1039/c7lc00795g · Cited by 89
Zhao, X., Seah, I., Xue, K., Wong, W., Tan, Q. S. W., Ma, X., Lin, Q., Lim, J. Y. C., Liu, Z., Parikh, B. H., et al. (2022) · Advanced Materials · doi:10.1002/adma.202108360 · Cited by 84
Chaves, J. C. S., Dando, S. J., White, A. R., & Oikari, L. E. (2024) · Biochimica et Biophysica Acta (BBA) - Molecular Basis of Disease · doi:10.1016/j.bbadis.2023.166967 · Cited by 62
Self-contained, low-cost Body-on-a-Chip systems for drug development
Wang, Y. I., Oleaga, C., Long, C. J., Esch, M. B., McAleer, C. W., Miller, P. G., Hickman, J. J., & Shuler, M. L. (2017) · Experimental Biology and Medicine · doi:10.1177/1535370217694101 · Cited by 59
“It can be performed non-invasively on live cells with quantitative and real-time readouts.(54) Figure 2 Functional measurements for Body-on-a-Chip systems.”
BackgroundSelf-citationThe Role of Fatty Acid Metabolites in Vaginal Health and Disease: Application to Candidiasis
Baldewijns, S., Sillen, M., Palmans, I., Vandecruys, P., Van Dijck, P., & Demuyser, L. (2021) · Frontiers in Microbiology · doi:10.3389/fmicb.2021.705779 · Cited by 44
Critical Considerations for the Design of Multi-Organ Microphysiological Systems (MPS)
Malik, M., Yang, Y., Fathi, P., Mahler, G. J., & Esch, M. B. (2021) · Frontiers in Cell and Developmental Biology · doi:10.3389/fcell.2021.721338 · Cited by 43
Self-citationIn vitro Methods for the Development and Analysis of Human Primary Airway Epithelia
Gianotti, A., Delpiano, L., & Caci, E. (2018) · Frontiers in Pharmacology · doi:10.3389/fphar.2018.01176 · Cited by 38
“These include Ussing chamber and Trans-Epithelial Electrical Resistance (TEER) techniques (Li et al., 2004; Srinivasan et al., 2015).”
MethodZhang, C.-X., Zhao, W.-Y., Liu, L., Ju, R.-J., Mu, L.-M., Zhao, Y., Zeng, F., Xie, H.-J., Yan, Y., & Lu, W.-L. (2015) · Oncotarget · doi:10.18632/oncotarget.5354 · Cited by 38
“The integrity of the BBB model was successfully confirmed by measuring the transendothelial electrical resistance (TEER, 165 Ω cm2) [26].”
MethodPolewski, M. A., Esquivel-Alvarado, D., Wedde, N. S., Kruger, C. G., & Reed, J. D. (2020) · Journal of Agricultural and Food Chemistry · doi:10.1021/acs.jafc.9b01689 · Cited by 36
Gupta, R., Chauhan, A., Kaur, T., Kuanr, B. K., & Sharma, D. (2022) · Nanoscale · doi:10.1039/d2nr02210a · Cited by 35
Laminin-driven Epac/Rap1 regulation of epithelial barriers on decellularized matrix
Young, B. M., Shankar, K., Tho, C. K., Pellegrino, A. R., & Heise, R. L. (2019) · Acta Biomaterialia · doi:10.1016/j.actbio.2019.10.009 · Cited by 33
Toor, A., Culibrk, L., Singhera, G. K., Moon, K.-M., Prudova, A., Foster, L. J., Moore, M. M., Dorscheid, D. R., & Tebbutt, S. J. (2018) · PLOS ONE · doi:10.1371/journal.pone.0209652 · Cited by 32
Lee, D. F., Lethem, M. I., & Lansley, A. B. (2021) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2021.07.016 · Cited by 30
Tanaka, M., Araujo, A. C., Valenti, V. E., Guiguer, E. L., Catharin, V. C. S., Gualhardi, C. M., de Souza Bastos Mazuqueli Pereira, E., de Alvares Goulart, R., de Argolo Haber, R. S., de Carvalho, A. C. A., et al. (2026) · International Journal of Molecular Sciences · doi:10.3390/ijms27052370 · Cited by 13
Boussommier-Calleja, A. (2020) · Bioengineering Innovative Solutions for Cancer · doi:10.1016/b978-0-12-813886-1.00013-9 · Cited by 10
Measurement of Transendothelial Electrical Resistance in Blood-Brain Barrier Endothelial Cells
Waithe, O. Y., Peng, X., Childs, E. W., & Tharakan, B. (2024) · Methods in Molecular Biology · doi:10.1007/978-1-0716-3429-5_16 · Cited by 10
Use of the MicroSiM (µSiM) Barrier Tissue Platform for Modeling the Blood-Brain Barrier
McCloskey, M. C., Kasap, P., Trempel, M., Widom, L. P., Kuebel, J., Chen, K., Gaborski, T. R., Engelhardt, B., & McGrath, J. L. (2024) · Journal of Visualized Experiments · doi:10.3791/65258 · Cited by 8
Shaughnessey, E. M., Kann, S. H., Charest, J. L., & Vedula, E. M. (2024) · Advanced Biology · doi:10.1002/adbi.202300127 · Cited by 1
Metadata
- Authors
- Srinivasan, B., Kolli, A. R., Esch, M. B., Abaci, H. E., Shuler, M. L., & Hickman, J. J.
- Venue
- SLAS Technology
- Publisher
- Elsevier BV
- Published
- 2015-04
- Volume
- 20
- Issue
- 2
- Pages
- 107-126
- ISSN
- 2472-6303 (ISSN-L)
- OpenAlex
- W2154555351
- Cited by
- 2,145
- References
- 126
- FWCI
- 34.98
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.