Physical Activity Classification Using the GENEA Wrist-Worn Accelerometer
The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Abstract
Introduction Most accelerometer-based activity monitors are worn on the waist or lower back for assessment of habitual physical activity. Output is in arbitrary counts that can be classified by activity intensity according to published thresholds. The purpose of this study was to develop methods to classify physical activities into walking, running, household, or sedentary activities based on raw acceleration data from the GENEA (Gravity Estimator of Normal Everyday Activity) and compare classification accuracy from a wrist-worn GENEA with a waist-worn GENEA. Methods Sixty participants (age = 49.4 ± 6.5 yr, body mass index = 24.6 ± 3.4 kg·m⁻²) completed an ordered series of 10-12 semistructured activities in the laboratory and outdoor environment. Throughout, three GENEA accelerometers were worn: one at the waist, one on the left wrist, and one on the right wrist. Acceleration data were collected at 80 Hz. Features obtained from both fast Fourier transform and wavelet decomposition were extracted, and machine learning algorithms were used to classify four types of daily activities including sedentary, household, walking, and running activities. Results The computational results demonstrated that the algorithm we developed can accurately classify certain types of daily activities, with high overall classification accuracy for both waist-worn GENEA (0.99) and wrist-worn GENEA (right wrist = 0.97, left wrist = 0.96). Conclusions We have successfully developed algorithms suitable…
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“a strong random forest model with tried-and-tested time series features, which has often been neglected in baseline model comparisons8,48–50.”
From Self-supervised learning for human activity recognition using 700,000 person-days of wearable data (2024) · cites this paper as [48]
Citations
Cites
Gene selection for cancer classification using support vector machines
Guyon, I., Weston, J., Barnhill, S., & Vapnik, V. (2002) · Machine Learning · doi:10.1023/a:1012487302797 · Cited by 9,954 · cited 1×
“Before training and testing, all the features were standardized, and Support Vector Machine feature evaluation method was applied to select the feature set best for the classification (17).”
MethodPhysical Activity in the United States Measured by Accelerometer
TROIANO, R. P., BERRIGAN, D., DODD, K. W., MÂSSE, L. C., TILERT, T., & MCDOWELL, M. (2008) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31815a51b3 · Cited by 7,638 · cited 1×
“For example, in the National Health and Nutrition Examination Survey in the United States (2003–2004), only 26% of the sample had seven valid days of accelerometer wear (35).”
Background(2007) · Circulation · doi:10.1161/circulationaha.107.185649 · Cited by 6,545 · cited 1×
“P hysical activity (PA) is important in improving health and reducing risk of disease (18,22,23).”
BackgroundActivity Recognition from User-Annotated Acceleration Data
Bao, L., & Intille, S. S. (2004) · Lecture Notes in Computer Science · doi:10.1007/978-3-540-24646-6_1 · Cited by 3,147
Validation of Accelerometer Wear and Nonwear Time Classification Algorithm
CHOI, L., LIU, Z., MATTHEWS, C. E., & BUCHOWSKI, M. S. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181ed61a3 · Cited by 1,804
The Technology of Accelerometry-Based Activity Monitors: Current and Future
CHEN, K. Y., & BASSETT, D. R. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185571.49104.82 · Cited by 996
Accelerometer Data Reduction: A Comparison of Four Reduction Algorithms on Select Outcome Variables
MÂSSE, L. C., FUEMMELER, B. F., ANDERSON, C. B., MATTHEWS, C. E., TROST, S. G., CATELLIER, D. J., & TREUTH, M. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185674.09066.8a · Cited by 676
Validation of the GENEA Accelerometer
ESLIGER, D. W., ROWLANDS, A. V., HURST, T. L., CATT, M., MURRAY, P., & ESTON, R. G. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31820513be · Cited by 625 · cited 6×
“ther, the household activity contained activities that would be classed as light intensity, but also activities that would be classed as moderate intensity (14); further research will aim to separate out light- and moderate-intensity household activities.”
BackgroundMethodResultInfluentialSelf-citationDirect measurement of human movement by accelerometry
Godfrey, A., Conway, R., Meagher, D., & ÓLaighin, G. (2008) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2008.09.005 · Cited by 591
Objective measurement of physical activity and sedentary behaviour: review with new data
Reilly, J. J., Penpraze, V, Hislop, J., Davies, G., Grant, S., & Paton, J. Y. (2008) · Archives of Disease in Childhood · doi:10.1136/adc.2007.133272 · Cited by 564
Cited by
Age Group Comparability of Raw Accelerometer Output from Wrist- and Hip-Worn Monitors
HILDEBRAND, M., VAN HEES, V. T., HANSEN, B. H., & EKELUND, U. (2014) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000289 · Cited by 1,043
Strath, S. J., Kaminsky, L. A., Ainsworth, B. E., Ekelund, U., Freedson, P. S., Gary, R. A., Richardson, C. R., Smith, D. T., & Swartz, A. M. (2013) · Circulation · doi:10.1161/01.cir.0000435708.67487.da · Cited by 1,029
Evolution of accelerometer methods for physical activity research
Troiano, R. P., McClain, J. J., Brychta, R. J., & Chen, K. Y. (2014) · British Journal of Sports Medicine · doi:10.1136/bjsports-2014-093546 · Cited by 968
Accelerometry and physical activity questionnaires - a systematic review
Skender, S., Ose, J., Chang-Claude, J., Paskow, M., Brühmann, B., Siegel, E. M., Steindorf, K., & Ulrich, C. M. (2016) · BMC Public Health · doi:10.1186/s12889-016-3172-0 · Cited by 449
The Current State of Physical Activity Assessment Tools
Ainsworth, B., Cahalin, L., Buman, M., & Ross, R. (2015) · Progress in Cardiovascular Diseases · doi:10.1016/j.pcad.2014.10.005 · Cited by 438
LifeLogging: Personal Big Data
Gurrin, C., Smeaton, A. F., & Doherty, A. R. (2014) · Foundations and Trends® in Information Retrieval · doi:10.1561/1500000033 · Cited by 434
Activity Recognition Using a Single Accelerometer Placed at the Wrist or Ankle
MANNINI, A., INTILLE, S. S., ROSENBERGER, M., SABATINI, A. M., & HASKELL, W. (2013) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31829736d6 · Cited by 383
Ellis, K., Kerr, J., Godbole, S., Lanckriet, G., Wing, D., & Marshall, S. (2014) · Physiological Measurement · doi:10.1088/0967-3334/35/11/2191 · Cited by 344
Sabia, S., van Hees, V. T., Shipley, M. J., Trenell, M. I., Hagger-Johnson, G., Elbaz, A., Kivimaki, M., & Singh-Manoux, A. (2014) · American Journal of Epidemiology · doi:10.1093/aje/kwt330 · Cited by 304
Willetts, M., Hollowell, S., Aslett, L., Holmes, C., & Doherty, A. (2018) · Scientific Reports · doi:10.1038/s41598-018-26174-1 · Cited by 250
“This labelled dataset for machine learning development and held-out validation is many times larger (~159,504 minutes of behaviour) than previous lab-based studies [330–3,600 mins 15,18,22 ] and free-living studies with short periods of direct observation [3,400–24,000 mins 23,24 ].”
MethodResultEstimating Activity and Sedentary Behavior from an Accelerometer on the Hip or Wrist
ROSENBERGER, M. E., HASKELL, W. L., ALBINALI, F., MOTA, S., NAWYN, J., & INTILLE, S. (2013) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31827f0d9c · Cited by 237
A review of signals used in sleep analysis
Roebuck, A., Monasterio, V, Gederi, E., Osipov, M., Behar, J., Malhotra, A., Penzel, T., & Clifford, G. D. (2014) · Physiological Measurement · doi:10.1088/0967-3334/35/1/r1 · Cited by 223
Field evaluation of a random forest activity classifier for wrist-worn accelerometer data
Pavey, T. G., Gilson, N. D., Gomersall, S. R., Clark, B., & Trost, S. G. (2017) · Journal of Science and Medicine in Sport · doi:10.1016/j.jsams.2016.06.003 · Cited by 174
A Method to Estimate Free-Living Active and Sedentary Behavior from an Accelerometer
LYDEN, K., KEADLE, S. K., STAUDENMAYER, J., & FREEDSON, P. S. (2014) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3182a42a2d · Cited by 170
Quante, M., Kaplan, E. R., Rueschman, M., Cailler, M., Buxton, O. M., & Redline, S. (2015) · Sleep Health · doi:10.1016/j.sleh.2015.09.002 · Cited by 167
Self-supervised learning for human activity recognition using 700,000 person-days of wearable data
Yuan, H., Chan, S., Creagh, A. P., Tong, C., Acquah, A., Clifton, D. A., & Doherty, A. (2024) · npj Digital Medicine · doi:10.1038/s41746-024-01062-3 · Cited by 166
“…for a network of the same architecture but fully trained from scratch, and a strong random forest model with tried-and-tested time series features, which has often been neglected in baseline model comparisons (Zhang et al., 2012; Mannini et al., 2013; Ellis et al., 2016; Willetts et al., 2018).”
BackgroundBakrania, K., Yates, T., Rowlands, A. V., Esliger, D. W., Bunnewell, S., Sanders, J., Davies, M., Khunti, K., & Edwardson, C. L. (2016) · PLOS ONE · doi:10.1371/journal.pone.0164045 · Cited by 165
Self-citationFarrahi, V., Niemelä, M., Kangas, M., Korpelainen, R., & Jämsä, T. J. (2018) · Gait & Posture · doi:10.1016/j.gaitpost.2018.12.003 · Cited by 175
Comparison of physical activity assessed using hip- and wrist-worn accelerometers
Kamada, M., Shiroma, E. J., Harris, T. B., & Lee, I.-M. (2016) · Gait & Posture · doi:10.1016/j.gaitpost.2015.11.005 · Cited by 151
Staudenmayer, J., He, S., Hickey, A., Sasaki, J., & Freedson, P. (2015) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00026.2015 · Cited by 139
Montoye, A. H. K., Moore, R. W., Bowles, H. R., Korycinski, R. W., & Pfeiffer, K. A. (2016) · British Journal of Sports Medicine · doi:10.1136/bjsports-2015-095947 · Cited by 154
A smartwatch-based framework for real-time and online assessment and mobility monitoring
Kheirkhahan, M., Nair, S., Davoudi, A., Rashidi, P., Wanigatunga, A. A., Corbett, D. B., Mendoza, T., Manini, T. M., & Ranka, S. (2019) · Journal of Biomedical Informatics · doi:10.1016/j.jbi.2018.11.003 · Cited by 138
Assessing Sedentary Behavior with the GENEActiv: Introducing the Sedentary Sphere
ROWLANDS, A. V., OLDS, T. S., HILLSDON, M., PULSFORD, R., HURST, T. L., ESTON, R. G., GOMERSALL, S. R., JOHNSTON, K., & LANGFORD, J. (2014) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000224 · Cited by 117
Self-citationComparability and feasibility of wrist- and hip-worn accelerometers in free-living adolescents.
Scott, J. J., Rowlands, A. V., Cliff, D. P., Morgan, P. J., Plotnikoff, R. C., & Lubans, D. R. (2017) · Journal of Science and Medicine in Sport · doi:10.1016/j.jsams.2017.04.017 · Cited by 120
Self-citationA Framework to Evaluate Devices That Assess Physical Behavior
Keadle, S. K., Lyden, K. A., Strath, S. J., STAUDENMAYER, J. W., & Freedson, P. S. (2019) · Exercise and Sport Sciences Reviews · doi:10.1249/jes.0000000000000206 · Cited by 122
Performance of activity classification algorithms in free-living older adults
SASAKI, J. E., HICKEY, A. M., STAUDENMAYER, J. W., JOHN, D., KENT, J. A., & FREEDSON, P. S. (2016) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000844 · Cited by 112
“Previous studies have reported high recognition rates for their algorithms for predefined activity routines comprising activities of fixed durations in laboratory conditions (1,2,15,19).”
BackgroundMethodResultInfluentialMcClung, H. L., Ptomey, L. T., Shook, R. P., Aggarwal, A., Gorczyca, A. M., Sazonov, E. S., Becofsky, K., Weiss, R., & Das, S. K. (2018) · American Journal of Preventive Medicine · doi:10.1016/j.amepre.2018.06.011 · Cited by 98
Calibration of raw accelerometer data to measure physical activity: A systematic review
Mendes, M. D. A., Crochemore‐Silva, I., Ramires, V. V., Reichert, F. F., Martins, R. C., & Tomasi, E. (2017) · Gait & Posture · doi:10.1016/j.gaitpost.2017.12.028 · Cited by 117
Small, S. R., Bullock, G. S., Khalid, S., Barker, K. L., Trivella, M., & Price, A. J. (2019) · BMJ Open · doi:10.1136/bmjopen-2019-033832 · Cited by 115
Machine Learning Models for Classifying Physical Activity in Free-Living Preschool Children
Ahmadi, M. N., Pavey, T., & Trost, S. G. (2020) · Sensors · doi:10.3390/s20164364 · Cited by 106
Cepeda, M., Koolhaas, C. M., van Rooij, F. J. A., Tiemeier, H. W., Guxens, M., Franco, O. H., & Schoufour, J. D. (2018) · Maturitas · doi:10.1016/j.maturitas.2018.01.016 · Cited by 109
Comment on “Estimating Activity and Sedentary Behavior from an Accelerometer on the Hip and Wrist”
FREEDSON, P. S., & JOHN, D. (2013) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31827f024d · Cited by 90
Establishing and Evaluating Wrist Cutpoints for the GENEActiv Accelerometer in Youth
SCHAEFER, C. A., NIGG, C. R., HILL, J. O., BRINK, L. A., & BROWNING, R. C. (2014) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000150 · Cited by 80
Narayanan, A., Desai, F., Stewart, T. I., Duncan, S., & Mackay, L. M. (2020) · Journal of Physical Activity and Health · doi:10.1123/jpah.2019-0088 · Cited by 96
Energy Expenditure Prediction Using Raw Accelerometer Data in Simulated Free Living
Montoye, A. H. K., Mudd, L. M., Biswas, S. K., & Pfeiffer, K. A. (2014) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000597 · Cited by 84
Activity Recognition in Youth Using Single Accelerometer Placed at Wrist or Ankle
Mannini, A., Rosenberger, M. E., Haskell, W. L., Sabatini, A. M., & Intille, S. S. (2016) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001144 · Cited by 93
A comparison of subjective and objective measures of physical activity from the Newcastle 85+ study
Innerd, P., Catt, M., Collerton, J. C., Davies, K., Trenell, M. I., Kirkwood, T. B. L., & Jagger, C. (2015) · Age and Ageing · doi:10.1093/ageing/afv062 · Cited by 89
Chong, J. L., Tjurin, P., Niemelä, M., Jämsä, T. J., & Farrahi, V. (2021) · Gait & Posture · doi:10.1016/j.gaitpost.2021.06.017 · Cited by 84
Montoye, A. H. K., Begum, M., Henning, Z., & Pfeiffer, K. A. (2017) · Physiological Measurement · doi:10.1088/1361-6579/38/2/343 · Cited by 83
Comparison of Raw Acceleration from the GENEA and ActiGraph™ GT3X+ Activity Monitors
John, D., Sasaki, J. E., STAUDENMAYER, J. W., Mavilia, M. G., & Freedson, P. S. (2013) · Sensors · doi:10.3390/s131114754 · Cited by 71
Assessment of Physical Activity of Hospitalised Older Adults: A Systematic Review
Lim, S. E. R., Ibrahim, K., Sayer, A. A., & Roberts, H. C. (2017) · The journal of nutrition health & aging · doi:10.1007/s12603-017-0931-2 · Cited by 75
Cameron, D. S., Bertenshaw, E. J., & Sheeran, P. (2017) · Psychology and Health · doi:10.1080/08870446.2017.1314477 · Cited by 77
Mehrang, S., Pietilä, J., & Korhonen, I. (2018) · Sensors · doi:10.3390/s18020613 · Cited by 74
WELCH, W. A., BASSETT, D. R., THOMPSON, D. L., FREEDSON, P. S., STAUDENMAYER, J. W., JOHN, D., STEEVES, J. A., CONGER, S. A., CEASER, T., HOWE, C. A., et al. (2013) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3182965249 · Cited by 66
Measuring Children's Physical Activity: Compliance Using Skin-Taped Accelerometers
Schneller, M. B., Bentsen, P., Nielsen, G., Brønd, J. C., Ried‐Larsen, M., Mygind, E., & Schipperijn, J. (2017) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001222 · Cited by 67
Real-World Gait Speed Estimation Using Wrist Sensor: A Personalized Approach
Soltani, A., Dejnabadi, H., Savary, M., & Aminian, K. (2019) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2019.2914940 · Cited by 67
Activity Classification Using the GENEA: Optimum Sampling Frequency and Number of Axes
ZHANG, S., MURRAY, P., ZILLMER, R., ESTON, R. G., CATT, M., & ROWLANDS, A. V. (2012) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31825e19fd · Cited by 58
Self-citationJakubowski, K., Farrugia, N., Halpern, A. R., Sankarpandi, S. K., & Stewart, L. (2015) · Memory & Cognition · doi:10.3758/s13421-015-0531-5 · Cited by 64
Challenges and Opportunities for Harmonizing Research Methodology: Raw Accelerometry
van Hees, V., Thaler-Kall, K., Wolf, K.-H., Brønd, J., Bonomi, A., Schulze, M., Vigl, M., Morseth, B., Hopstock, L. A., Gorzelniak, L., et al. (2016) · Methods of Information in Medicine · doi:10.3414/me15-05-0013 · Cited by 58
Comparability of Measured Acceleration from Accelerometry-Based Activity Monitors
Rowlands, A. V., Fraysse, F., Catt, M., Stiles, V. H., Stanley, R. M., Eston, R. G., & Olds, T. S. (2015) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000394 · Cited by 60
Self-citationAwais, M., Raza, M., Ali, K., Ali, Z., Irfan, M., Chughtai, O., Khan, I., Kim, S., & Rehman, M. U. (2019) · Sensors · doi:10.3390/s19112498 · Cited by 66
Issues Related to Measuring and Interpreting Objectively Measured Sedentary Behavior Data
Janssen, X., & Cliff, D. P. (2015) · Measurement in Physical Education and Exercise Science · doi:10.1080/1091367x.2015.1045908 · Cited by 66
Assessment of walking, running, and jumping movement features by using the inertial measurement unit
Lee, Y.-S., Ho, C.-S., Shih, Y., Chang, S.-Y., Róbert, F. J., & Shiang, T.-Y. (2015) · Gait & Posture · doi:10.1016/j.gaitpost.2015.03.007 · Cited by 58
Actigraphy to Measure Physical Activity in the Intensive Care Unit: A Systematic Review
Schwab, K. E., To, A., Chang, J. J., Ronish, B., Needham, D. M., Martin, J. L., & Kamdar, B. B. (2019) · Journal of Intensive Care Medicine · doi:10.1177/0885066619863654 · Cited by 56
Wrist-worn accelerometers in assessment of energy expenditure during intensive training
Kinnunen, H., Tanskanen, M., Kyröläinen, H., & Westerterp, K. R. (2012) · Physiological Measurement · doi:10.1088/0967-3334/33/11/1841 · Cited by 53
Validation of the AX3 triaxial accelerometer in older functionally impaired people
Clarke, C., Taylor, J., Crighton, L. J., Goodbrand, J. A., McMurdo, M. E. T., & Witham, M. D. (2016) · Aging Clinical and Experimental Research · doi:10.1007/s40520-016-0604-8 · Cited by 53
Measurement of Physical Activity Using Accelerometers
Sasaki, J. E., da Silva, K. S., da Costa, B. G. G., & John, D. (2016) · Elsevier eBooks · doi:10.1016/b978-0-12-802075-3.00002-4 · Cited by 79
Accelerometry-based recognition of the placement sites of a wearable sensor
Mannini, A., Sabatini, A. M., & Intille, S. S. (2015) · Pervasive and Mobile Computing · doi:10.1016/j.pmcj.2015.06.003 · Cited by 58
Human Factors in AI-Driven Digital Solutions for Increasing Physical Activity: Scoping Review
Gabarrón, E., Larbi, D., Rivera-Romero, O., & Denecke, K. (2024) · JMIR Human Factors · doi:10.2196/55964 · Cited by 54
Impact of study design on development and evaluation of an activity-type classifier
van Hees, V. T., Golubic, R., Ekelund, U., & Brage, S. (2013) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00984.2012 · Cited by 49
Sit-to-Stand Transition Reveals Acute Fall Risk in Activities of Daily Living
Pozaic, T., Lindemann, U., Grebe, A.-K., & Stork, W. (2016) · IEEE Journal of Translational Engineering in Health and Medicine · doi:10.1109/jtehm.2016.2620177 · Cited by 48
Classifier Personalization for Activity Recognition Using Wrist Accelerometers
Mannini, A., & Intille, S. S. (2018) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2018.2869779 · Cited by 53
Daily physical activity patterns from hip- and wrist-worn accelerometers
Shiroma, E. J., Schepps, M. A., Harezlak, J., Chen, K. Y., Matthews, C. E., Koster, A., Caserotti, P., Glynn, N. W., & Harris, T. B. (2016) · Physiological Measurement · doi:10.1088/0967-3334/37/10/1852 · Cited by 50
Predicting Human Movement with Multiple Accelerometers Using Movelets
HE, B., BAI, J., ZIPUNNIKOV, V. V., KOSTER, A., CASEROTTI, P., LANGE-MAIA, B., GLYNN, N. W., HARRIS, T. B., & CRAINICEANU, C. M. (2014) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000285 · Cited by 40
Park, H. S., Dong, S.-Y., Lee, M., & Youn, I. (2017) · Sensors · doi:10.3390/s17071698 · Cited by 42
Early detection of physical activity for people with type 1 diabetes mellitus
Dasanayake, I. S., Bevier, W. C., Castorino, K., Pinsker, J. E., Seborg, D. E., Doyle, F. J., & Dassau, E. (2015) · Journal of Diabetes Science and Technology · doi:10.1177/1932296815592409 · Cited by 40
Montoye, A. H. K., Pivarnik, J. M., Mudd, L. M., Biswas, S. K., & Pfeiffer, K. A. (2016) · Measurement in Physical Education and Exercise Science · doi:10.1080/1091367x.2016.1192038 · Cited by 39
Neil‐Sztramko, S., Rafn, B. S., Gotay, C. C., & Campbell, K. L. (2017) · Physiology & Behavior · doi:10.1016/j.physbeh.2017.01.026 · Cited by 40
Orientações para utilização de acelerômetros no Brasil
Sasaki, J. E., Coutinho, A. P. P., Santos, C., Bertuol, C., Minatto, G., Berria, J., Tonosaki, L. M. D., de Lima, L. R. A., Marchesan, M., da Silveira, P. M., et al. (2017) · Revista Brasileira de Atividade Física & Saúde · doi:10.12820/rbafs.v.22n2p110-126 · Cited by 70
Montoye, A. H. K., Westgate, B. S., Fonley, M., & Pfeiffer, K. A. (2018) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00760.2017 · Cited by 39
Jung, S., Michaud, M., Oudre, L., Dorveaux, É., Gorintin, L., Vayatis, N., & Ricard, D. (2020) · Sensors · doi:10.3390/s20195625 · Cited by 41
Small, S. R., Khalid, S., Dhiman, P., Chan, S., Jackson, D., Doherty, A., & Price, A. J. (2021) · Journal for the Measurement of Physical Behaviour · doi:10.1123/jmpb.2020-0061 · Cited by 39
Buchan, D. S., McSeveney, F., & McLellan, G. (2018) · Clinical Physiology and Functional Imaging · doi:10.1111/cpf.12538 · Cited by 42
Akther, S., Saleheen, N., Samiei, S. A., Shetty, V., Ertin, E., & Kumar, S. (2019) · Proceedings of the ACM on Interactive Mobile Wearable and Ubiquitous Technologies · doi:10.1145/3314388 · Cited by 48
Koolhaas, C. M., van Rooij, F. J. A., Cepeda, M., Tiemeier, H. W., Franco, O. H., & Schoufour, J. D. (2017) · Clinical Epidemiology · doi:10.2147/clep.s147613 · Cited by 47
Kate, R. J., Swartz, A. M., Welch, W. A., & Strath, S. J. (2016) · Physiological Measurement · doi:10.1088/0967-3334/37/3/360 · Cited by 40
Sirichana, W., Dolezal, B. A., Neufeld, E. V., Wang, X., & Cooper, C. B. (2017) · Journal of science and medicine in sport · doi:10.1016/j.jsams.2017.01.233 · Cited by 38
Strath, S. J., Kate, R. J., Keenan, K. G., Welch, W. A., & Swartz, A. M. (2015) · Physiological Measurement · doi:10.1088/0967-3334/36/11/2335 · Cited by 34
Litt, J., Alaimo, K., Buchenau, M., Villalobos, A., Glueck, D. H., Crume, T., Fahnestock, L., Hamman, R. F., Hébert, J. R., Hurley, T. G., et al. (2018) · Contemporary Clinical Trials · doi:10.1016/j.cct.2018.03.005 · Cited by 35
Farrahi, V., Niemelä, M., Tjurin, P., Kangas, M., Korpelainen, R., & Jämsä, T. J. (2019) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2019.2917565 · Cited by 34
Review of Machine Learning and Deep Learning Based Recommender Systems for Health Informatics
Saha, J., Chowdhury, C., & Biswas, S. (2019) · Studies in big data · doi:10.1007/978-3-030-33966-1_6 · Cited by 39
Data Analytics in Physical Activity Studies With Accelerometers: Scoping Review
Liang, Y., Wang, C. I., & Hsiao, C. K. (2024) · Journal of Medical Internet Research · doi:10.2196/59497 · Cited by 34
Prediction of sustained harmonic walking in the free-living environment using raw accelerometry data
Urbanek, J. K., Zipunnikov, V., Harris, T. B., Fadel, W. F., Glynn, N. W., Koster, A., Caserotti, P., Crainiceanu, C., & Harezlak, J. (2018) · Physiological Measurement · doi:10.1088/1361-6579/aaa74d · Cited by 32
Activity recognition for medical teamwork based on passive RFID
Li, X., Yao, D., Pan, X., Johannaman, J., Yang, J., Webman, R. B., Sarcevic, A., Marsic, I., & Burd, R. S. (2016) · IEEE International Conference on RFID · doi:10.1109/rfid.2016.7488002 · Cited by 33
Real-World Gait Bout Detection Using a Wrist Sensor: An Unsupervised Real-Life Validation
Soltani, A., Paraschiv-Ionescu, A., Dejnabadi, H., Marques-Vidal, P. M., & Aminian, K. (2020) · IEEE Access · doi:10.1109/access.2020.2998842 · Cited by 30
Identifying Free-Living Physical Activities Using Lab-Based Models with Wearable Accelerometers
Dutta, A., Ma, O., Toledo, M. J. L., Flórez-Pregonero, A., Ainsworth, B. E., Buman, M. P., & Bliss, D. W. (2018) · Sensors · doi:10.3390/s18113893 · Cited by 32
O’Driscoll, R., Turicchi, J., Hopkins, M., Duarte, C., Horgan, G. W., Finlayson, G., & Stubbs, R. J. (2021) · JMIR mhealth and uhealth · doi:10.2196/23938 · Cited by 32
Deep Learning for Classifying Physical Activities from Accelerometer Data
Nunavath, V., Johansen, S., Johannessen, T. S., Jiao, L., Hansen, B. H., Berntsen, S., & Goodwin, M. (2021) · Sensors · doi:10.3390/s21165564 · Cited by 32
Physical activity characterization: does one site fit all?
Clark, C. C. T., Nobre, G. C., Fernandes, J. F. T., Moran, J., Drury, B., Mannini, A., Gronek, P., & Podstawski, R. (2018) · Physiological Measurement · doi:10.1088/1361-6579/aadad0 · Cited by 30
Wrist-independent energy expenditure prediction models from raw accelerometer data
Montoye, A. H. K., Pivarnik, J. M., Mudd, L. M., Biswas, S. K., & Pfeiffer, K. A. (2016) · Physiological Measurement · doi:10.1088/0967-3334/37/10/1770 · Cited by 27
On-Board Feature Extraction from Acceleration Data for Activity Recognition
Elsts, A., McConville, R., Fafoutis, X., Twomey, N., Piechocki, R. J., Santos‐Rodríguez, R., & Craddock, I. J. (2018) · Explore Bristol Research · doi:10.5555/3234847.3234868 · Cited by 27
Use of Accelerometry for Long Term Monitoring of Stroke Patients
Lucas, A., Hermiz, J., Labuzetta, J., Arabadzhi, Y., Karanjia, N., & Gilja, V. (2019) · IEEE Journal of Translational Engineering in Health and Medicine · doi:10.1109/jtehm.2019.2897306 · Cited by 26
ROAMM: A software infrastructure for real-time monitoring of personal health
Nair, S., Kheirkhahan, M., Davoudi, A., Rashidi, P., Wanigatunga, A. A., Corbett, D. B., Manini, T. M., & Ranka, S. (2016) · IEEE International Conference on e-Health Networking, Applications and Services (Healthcom) · doi:10.1109/healthcom.2016.7749479 · Cited by 25
Domingo, C. H., Hernando, C., Collado‐Boira, E., Panizo, N., Martínez‐Navarro, I., & Hernando, B. (2018) · PLoS ONE · doi:10.1371/journal.pone.0202815 · Cited by 25
Schwendinger, F., Wagner, J., Infanger, D., Schmidt‐Trucksäss, A., & Knaier, R. (2021) · BMC Medical Research Methodology · doi:10.1186/s12874-021-01350-6 · Cited by 25
Augustin, N. H., Mattocks, C., Faraway, J. J., Greven, S., & Ness, A. (2015) · Statistical Methods in Medical Research · doi:10.1177/0962280215595832 · Cited by 25
Gilmore, J., & Nasseri, M. (2024) · Sensors · doi:10.3390/s24103005 · Cited by 24
Sheng, B., Moosman, O. M., Cruz, B. D. P., del Pozo-Cruz, J., Alfonso‐Rosa, R. M., & Zhang, Y. (2020) · Measurement · doi:10.1016/j.measurement.2020.107480 · Cited by 29
Posture and Physical Activity Detection: Impact of Number of Sensors and Feature Type
Tang, Q., John, D., Thapa-Chhetry, B., ARGUELLO, D. J., & Intille, S. S. (2020) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000002306 · Cited by 26
Mehrang, S., Pietilä, J., Tolonen, J., Helander, E. E., Jimison, H. B., Pavel, M., & Korhonen, I. (2017) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-981-10-5122-7_147 · Cited by 27
Metadata
- Authors
- ZHANG, S., ROWLANDS, A. V., MURRAY, P., & HURST, T. L.
- Affiliations
- Unilever (United Kingdom) (GB)
- University of South Australia (AU)
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2012-04
- Volume
- 44
- Issue
- 4
- Pages
- 742-748
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2048606477
- Cited by
- 233
- References
- 35
- Citations by year
- 2026: 4 · 2025: 6 · 2024: 8 · 2023: 6 · 2022: 11 · 2021: 29 · 2020: 15 · 2019: 20 · 2018: 25 · 2017: 26 · 2016: 26 · 2015: 17 · 2014: 17 · 2013: 15 · 2012: 7
- FWCI
- 13.44
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Medicine & Science in Sports & Exercise (publishedVersion)
- PubMed (publishedVersion)
- Adelaide Research & Scholarship (AR&S) (University of Adelaide) (submittedVersion)
- Topics
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Physical Activity and Health
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Keywords
- physical activity classification, wrist-worn accelerometers, waist-worn accelerometers, walking, running, sedentary behavior, housework, physical activity intensity, wavelet decomposition, fast Fourier transform, machine learning classification, wearable activity trackers
- MeSH terms
- Activities of Daily Living, Adult, Algorithms, Female, Humans, Male, Middle Aged, Motor Activity, Running, Walking, Monitoring, Ambulatory
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.