Physical Activity Classification Using the GENEA Wrist-Worn Accelerometer
The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Abstract
Introduction Most accelerometer-based activity monitors are worn on the waist or lower back for assessment of habitual physical activity. Output is in arbitrary counts that can be classified by activity intensity according to published thresholds. The purpose of this study was to develop methods to classify physical activities into walking, running, household, or sedentary activities based on raw acceleration data from the GENEA (Gravity Estimator of Normal Everyday Activity) and compare classification accuracy from a wrist-worn GENEA with a waist-worn GENEA. Methods Sixty participants (age = 49.4 ± 6.5 yr, body mass index = 24.6 ± 3.4 kg·m⁻²) completed an ordered series of 10-12 semistructured activities in the laboratory and outdoor environment. Throughout, three GENEA accelerometers were worn: one at the waist, one on the left wrist, and one on the right wrist. Acceleration data were collected at 80 Hz. Features obtained from both fast Fourier transform and wavelet decomposition were extracted, and machine learning algorithms were used to classify four types of daily activities including sedentary, household, walking, and running activities. Results The computational results demonstrated that the algorithm we developed can accurately classify certain types of daily activities, with high overall classification accuracy for both waist-worn GENEA (0.99) and wrist-worn GENEA (right wrist = 0.97, left wrist = 0.96). Conclusions We have successfully developed algorithms suitable…
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“a strong random forest model with tried-and-tested time series features, which has often been neglected in baseline model comparisons8,48–50.”
From Self-supervised learning for human activity recognition using 700,000 person-days of wearable data (2024) · cites this paper as [48]
Citations
Cites
Gene selection for cancer classification using support vector machines
Guyon, I., Weston, J., Barnhill, S., & Vapnik, V. (2002) · Machine Learning · doi:10.1023/a:1012487302797 · Cited by 9,954 · cited 1×
“Before training and testing, all the features were standardized, and Support Vector Machine feature evaluation method was applied to select the feature set best for the classification (17).”
MethodPhysical Activity in the United States Measured by Accelerometer
TROIANO, R. P., BERRIGAN, D., DODD, K. W., MÂSSE, L. C., TILERT, T., & MCDOWELL, M. (2008) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31815a51b3 · Cited by 7,638 · cited 1×
“For example, in the National Health and Nutrition Examination Survey in the United States (2003–2004), only 26% of the sample had seven valid days of accelerometer wear (35).”
Background(2007) · Circulation · doi:10.1161/circulationaha.107.185649 · Cited by 6,545 · cited 1×
“P hysical activity (PA) is important in improving health and reducing risk of disease (18,22,23).”
BackgroundActivity Recognition from User-Annotated Acceleration Data
Bao, L., & Intille, S. S. (2004) · Lecture Notes in Computer Science · doi:10.1007/978-3-540-24646-6_1 · Cited by 3,147
Validation of Accelerometer Wear and Nonwear Time Classification Algorithm
CHOI, L., LIU, Z., MATTHEWS, C. E., & BUCHOWSKI, M. S. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181ed61a3 · Cited by 1,804
The Technology of Accelerometry-Based Activity Monitors: Current and Future
CHEN, K. Y., & BASSETT, D. R. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185571.49104.82 · Cited by 996
Accelerometer Data Reduction: A Comparison of Four Reduction Algorithms on Select Outcome Variables
MÂSSE, L. C., FUEMMELER, B. F., ANDERSON, C. B., MATTHEWS, C. E., TROST, S. G., CATELLIER, D. J., & TREUTH, M. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185674.09066.8a · Cited by 676
Validation of the GENEA Accelerometer
ESLIGER, D. W., ROWLANDS, A. V., HURST, T. L., CATT, M., MURRAY, P., & ESTON, R. G. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31820513be · Cited by 625 · cited 6×
“ther, the household activity contained activities that would be classed as light intensity, but also activities that would be classed as moderate intensity (14); further research will aim to separate out light- and moderate-intensity household activities.”
BackgroundMethodResultInfluentialSelf-citationDirect measurement of human movement by accelerometry
Godfrey, A., Conway, R., Meagher, D., & ÓLaighin, G. (2008) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2008.09.005 · Cited by 591
Objective measurement of physical activity and sedentary behaviour: review with new data
Reilly, J. J., Penpraze, V, Hislop, J., Davies, G., Grant, S., & Paton, J. Y. (2008) · Archives of Disease in Childhood · doi:10.1136/adc.2007.133272 · Cited by 564
Preece, S. J., Goulermas, J. Y., Kenney, L. P. J., & Howard, D. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2006190 · Cited by 551 · cited 1×
“The STFT still requires extra parameter choices, such as window size, to be made (28).”
BackgroundSedentary Activity Associated With Metabolic Syndrome Independent of Physical Activity
Bankoski, A., Harris, T. B., McClain, J. J., Brychta, R. J., Caserotti, P., Chen, K. Y., Berrigan, D., Troiano, R. P., & Koster, A. (2011) · Diabetes Care · doi:10.2337/dc10-0987 · Cited by 535
Validity of accelerometry for the assessment of moderate intensity physical activity in the field
HENDELMAN, D., MILLER, K., BAGGETT, C., DEBOLD, E., & FREEDSON, P. (2000) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200009001-00002 · Cited by 516
Detection of static and dynamic activities using uniaxial accelerometers
Veltink, P. H., Bussmann, H. J., de Vries, W., Martens, W. J., & Van Lummel, R. C. (1996) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.547939 · Cited by 491
Assessment of energy expenditure for physical activity using a triaxial accelerometer
BOUTEN, C. V., WESTERTERP, K. R., VERDUIN, M., & JANSSEN, J. D. (1994) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-199412000-00016 · Cited by 451
Evidence for secular trends in children's physical activity behaviour
Dollman, J., Norton, K., & Norton, L. (2005) · British Journal of Sports Medicine · doi:10.1136/bjsm.2004.016675 · Cited by 427 · cited 1×
“Accurate measurement of PA is essential in evaluating the efficacy of interventions and understanding of the relationship between PA and health (5,6,13,29,30).”
BackgroundClassifying household and locomotive activities using a triaxial accelerometer
Oshima, Y., Kawaguchi, K., Tanaka, S., Ohkawara, K., Hikihara, Y., Ishikawa-Takata, K., & Tabata, I. (2010) · Gait & Posture · doi:10.1016/j.gaitpost.2010.01.005 · Cited by 371
Staudenmayer, J., Pober, D., Crouter, S., Bassett, D., & Freedson, P. (2009) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00465.2009 · Cited by 361
A novel method for using accelerometer data to predict energy expenditure
Crouter, S. E., Clowers, K. G., & Bassett, D. R. (2006) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00818.2005 · Cited by 345
Physical Activity, Obesity, and the Incidence of Type 2 Diabetes in a High-Risk Population
Kriska, A. M. (2003) · American Journal of Epidemiology · doi:10.1093/aje/kwg191 · Cited by 259
Detection of Type, Duration, and Intensity of Physical Activity Using an Accelerometer
BONOMI, A. G., GORIS, A. H. C., YIN, B., & WESTERTERP, K. R. (2009) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181a24536 · Cited by 245
Development of Novel Techniques to Classify Physical Activity Mode Using Accelerometers
POBER, D. M., STAUDENMAYER, J., RAPHAEL, C., & FREEDSON, P. S. (2006) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000227542.43669.45 · Cited by 210
Discrimination of walking patterns using wavelet-based fractal analysis
Sekine, M., Tamura, T., Akay, M., Fujimoto, T., Togawa, T., & Fukui, Y. (2002) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2002.802879 · Cited by 201
Physical activity measurement- a primer for health promotion
Bauman, A., Phongsavan, P., Schoeppe, S., & Owen, N. (2006) · Promotion & Education · doi:10.1177/10253823060130020103 · Cited by 199
Lagerros, Y. T., & Lagiou, P. (2007) · European Journal of Epidemiology · doi:10.1007/s10654-007-9154-x · Cited by 178
Assessment of Differing Definitions of Accelerometer Nonwear Time
Evenson, K. R., & Terry, J. W. (2009) · Research Quarterly for Exercise and Sport · doi:10.1080/02701367.2009.10599570 · Cited by 121
Real-time Daily Activity Classification with Wireless Sensor Networks using Hidden Markov Model
He, J., Li, H., & Tan, J. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4353008 · Cited by 86
Evaluation of Neural Networks to Identify Types of Activity Using Accelerometers
DE VRIES, S. I., GARRE, F. G., ENGBERS, L. H., HILDEBRANDT, V. H., & VAN BUUREN, S. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181e5797d · Cited by 83
Walk Detection With a Kinematic Sensor: Frequency and Wavelet Comparison
Barralon, P., Vuillerme, N., & Noury, N. (2006) · 2006 International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2006.260770 · Cited by 79
Physical Activity and Body Mass Index of Children in an Old Order Amish Community
BASSETT, D. R., TREMBLAY, M. S., ESLIGER, D. W., COPELAND, J. L., BARNES, J. D., & HUNTINGTON, G. E. (2007) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31802d3aa7 · Cited by 70
Clinical use of physical activity measures
Reiser, L. M., & Schlenk, E. A. (2009) · Journal of the American Academy of Nurse Practitioners · doi:10.1111/j.1745-7599.2008.00389.x · Cited by 45
Classification of Daily Physical Activities from a Single Kinematic Sensor
Barralon, P., Noury, N., & Vuillerme, N. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2005.1616963 · Cited by 37
Estimation of Walking Energy Expenditure by Using Support Vector Regression
Su, S. W., Wang, L., Celler, B. G., Eliathamby Ambikairajah, A., & Savkin, A. V. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2005.1617240 · Cited by 31
Identification of Tasks Performed by Stroke Patients Using a Mobility Assistive Device
Hester, T., Sherrill, D. M., Hamel, M., Perreault, K., Boissy, P., & Bonato, P. (2006) · Conference proceedings · doi:10.1109/iembs.2006.259437 · Cited by 23
Noury, N., Barralon, P., Couturier, P., Favre-Reguillon, F., Guillemaud, R., Mestais, C., Caritu, Y., David, D., Moine, S., Franco, A., et al. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2004.1403929 · Cited by 7
Cited by
Age Group Comparability of Raw Accelerometer Output from Wrist- and Hip-Worn Monitors
HILDEBRAND, M., VAN HEES, V. T., HANSEN, B. H., & EKELUND, U. (2014) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000289 · Cited by 1,043
Strath, S. J., Kaminsky, L. A., Ainsworth, B. E., Ekelund, U., Freedson, P. S., Gary, R. A., Richardson, C. R., Smith, D. T., & Swartz, A. M. (2013) · Circulation · doi:10.1161/01.cir.0000435708.67487.da · Cited by 1,029
Evolution of accelerometer methods for physical activity research
Troiano, R. P., McClain, J. J., Brychta, R. J., & Chen, K. Y. (2014) · British Journal of Sports Medicine · doi:10.1136/bjsports-2014-093546 · Cited by 968
Accelerometry and physical activity questionnaires - a systematic review
Skender, S., Ose, J., Chang-Claude, J., Paskow, M., Brühmann, B., Siegel, E. M., Steindorf, K., & Ulrich, C. M. (2016) · BMC Public Health · doi:10.1186/s12889-016-3172-0 · Cited by 449
The Current State of Physical Activity Assessment Tools
Ainsworth, B., Cahalin, L., Buman, M., & Ross, R. (2015) · Progress in Cardiovascular Diseases · doi:10.1016/j.pcad.2014.10.005 · Cited by 438
Metadata
- Authors
- ZHANG, S., ROWLANDS, A. V., MURRAY, P., & HURST, T. L.
- Affiliations
- Unilever (United Kingdom) (GB)
- University of South Australia (AU)
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2012-04
- Volume
- 44
- Issue
- 4
- Pages
- 742-748
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2048606477
- Cited by
- 233
- References
- 35
- Citations by year
- 2026: 4 · 2025: 6 · 2024: 8 · 2023: 6 · 2022: 11 · 2021: 29 · 2020: 15 · 2019: 20 · 2018: 25 · 2017: 26 · 2016: 26 · 2015: 17 · 2014: 17 · 2013: 15 · 2012: 7
- FWCI
- 13.44
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Medicine & Science in Sports & Exercise (publishedVersion)
- PubMed (publishedVersion)
- Adelaide Research & Scholarship (AR&S) (University of Adelaide) (submittedVersion)
- Topics
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Physical Activity and Health
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Keywords
- physical activity classification, wrist-worn accelerometers, waist-worn accelerometers, walking, running, sedentary behavior, housework, physical activity intensity, wavelet decomposition, fast Fourier transform, machine learning classification, wearable activity trackers
- MeSH terms
- Activities of Daily Living, Adult, Algorithms, Female, Humans, Male, Middle Aged, Motor Activity, Running, Walking, Monitoring, Ambulatory
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.