The DOI matches its Crossref record; 49 of the 49 references it cites were found in a registry or an index.
Depth Sensitivity and Source-Detector Separations for Near Infrared Spectroscopy Based on the Colin27 Brain Template
Open accessAbstract
Understanding the spatial and depth sensitivity of non-invasive near-infrared spectroscopy (NIRS) measurements to brain tissue-i.e., near-infrared neuromonitoring (NIN) - is essential for designing experiments as well as interpreting research findings. However, a thorough characterization of such sensitivity in realistic head models has remained unavailable. In this study, we conducted 3,555 Monte Carlo (MC) simulations to densely cover the scalp of a well-characterized, adult male template brain (Colin27). We sought to evaluate: (i) the spatial sensitivity profile of NIRS to brain tissue as a function of source-detector separation, (ii) the NIRS sensitivity to brain tissue as a function of depth in this realistic and complex head model, and (iii) the effect of NIRS instrument sensitivity on detecting brain activation. We found that increasing the source-detector (SD) separation from 20 to 65 mm provides monotonic increases in sensitivity to brain tissue. For every 10 mm increase in SD separation (up to ~45 mm), sensitivity to gray matter increased an additional 4%. Our analyses also demonstrate that sensitivity in depth (S) decreases exponentially, with a "rule-of-thumb" formula S=0.75*0.85(depth). Thus, while the depth sensitivity of NIRS is not strictly limited, NIN signals in adult humans are strongly biased towards the outermost 10-15 mm of intracranial space. These general results, along with the detailed quantitation of sensitivity estimates around the head, can provide detailed guidance for interpreting the likely sources of NIRS signals, as well as help NIRS investigators design and plan better NIRS experiments, head probes and instruments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Advances in functional and structural MR image analysis and implementation as FSL
Smith, S. M., Jenkinson, M., Woolrich, M. W., Beckmann, C. F., Behrens, T. E. J., Johansen-Berg, H., Bannister, P. R., De Luca, M., Drobnjak, I., Flitney, D. E., et al. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.051 · Cited by 13,630 · cited 1×
“1 [42].”
Fast robust automated brain extraction
Smith, S. M. (2002) · Human Brain Mapping · doi:10.1002/hbm.10062 · Cited by 10,496
Ashburner, J., & Friston, K. J. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.02.018 · Cited by 7,507 · cited 1×
“To this scan, we applied the default SPM8 segmentation process [43] which generated three tissue type probability images: gray matter, white matter and cerebrospinal fluid (CSF).”
MCML—Monte Carlo modeling of light transport in multi-layered tissues
Wang, L., Jacques, S. L., & Zheng, L. (1995) · Computer Methods and Programs in Biomedicine · doi:10.1016/0169-2607(95)01640-f · Cited by 3,324
Dynamics of the Hippocampal Ensemble Code for Space
Wilson, M. A., & McNaughton, B. L. (1993) · Science · doi:10.1126/science.8351520 · Cited by 2,350
Patterson, M. S., Chance, B., & Wilson, B. C. (1989) · Applied Optics · doi:10.1364/ao.28.002331 · Cited by 2,087
Non-invasive optical spectroscopy and imaging of human brain function
Villringer, A., & Chance, B. (1997) · Trends in Neurosciences · doi:10.1016/s0166-2236(97)01132-6 · Cited by 1,618
Enhancement of MR Images Using Registration for Signal Averaging
Holmes, C. J., Hoge, R., Collins, L., Woods, R., Toga, A. W., & Evans, A. C. (1998) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199803000-00032 · Cited by 1,417
Okamoto, M., Dan, H., Sakamoto, K., Takeo, K., Shimizu, K., Kohno, S., Oda, I., Isobe, S., Suzuki, T., Kohyama, K., et al. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2003.08.026 · Cited by 1,320
Principles, Techniques, and Limitations of Near Infrared Spectroscopy
Ferrari, M., Mottola, L., & Quaresima, V. (2004) · Canadian Journal of Applied Physiology · doi:10.1139/h04-031 · Cited by 997
Non-invasive neuroimaging using near-infrared light
Strangman, G., Boas, D. A., & Sutton, J. P. (2002) · Biological Psychiatry · doi:10.1016/s0006-3223(02)01550-0 · Cited by 903
Self-citationSpectroscopy and Imaging with Diffusing Light
Yodh, A., & Chance, B. (1995) · Physics Today · doi:10.1063/1.881445 · Cited by 800
A finite element approach for modeling photon transport in tissue
Arridge, S. R., Schweiger, M., Hiraoka, M., & Delpy, D. T. (1993) · Medical Physics · doi:10.1118/1.597069 · Cited by 635
Boas, D. A., Culver, J. P., Stott, J. J., & Dunn, A. K. (2002) · Optics Express · doi:10.1364/oe.10.000159 · Cited by 599
Arridge, S. R., Cope, M., & Delpy, D. T. (1992) · Physics in Medicine and Biology · doi:10.1088/0031-9155/37/7/005 · Cited by 595
Okada, E., Firbank, M., Schweiger, M., Arridge, S. R., Cope, M., & Delpy, D. T. (1997) · Applied Optics · doi:10.1364/ao.36.000021 · Cited by 477
Duncan, A., Meek, J. H., Clemence, M., Elwell, C. E., Fallon, P., Tyszczuk, L., Cope, M., & Delpy, D. T. (1996) · Pediatric Research · doi:10.1203/00006450-199605000-00025 · Cited by 469
In vivo local determination of tissue optical properties: applications to human brain
Bevilacqua, F., Piguet, D., Marquet, P., Gross, J. D., Tromberg, B. J., & Depeursinge, C. (1999) · Applied Optics · doi:10.1364/ao.38.004939 · Cited by 456
Hiraoka, M., Firbank, M., Essenpreis, M., Cope, M., Arridge, S. R., Zee, P. V. D., & Delpy, D. T. (1993) · Physics in Medicine and Biology · doi:10.1088/0031-9155/38/12/011 · Cited by 374
Okada, E., & Delpy, D. T. (2003) · Applied Optics · doi:10.1364/ao.42.002915 · Cited by 364
Hielscher, A. H., Alcouffe, R. E., & Barbour, R. L. (1998) · Physics in Medicine and Biology · doi:10.1088/0031-9155/43/5/017 · Cited by 332
Diffusion of light in turbid material
Ishimaru, A. (1989) · Applied Optics · doi:10.1364/ao.28.002210 · Cited by 325
Profio, A. E. (1989) · Applied Optics · doi:10.1364/ao.28.002216 · Cited by 305
Fukui, Y., Ajichi, Y., & Okada, E. (2003) · Applied Optics · doi:10.1364/ao.42.002881 · Cited by 286
Okada, E., & Delpy, D. T. (2003) · Applied Optics · doi:10.1364/ao.42.002906 · Cited by 274
Monte Carlo Modeling of Light Transport in Tissues
Jacques, S. L., & Wang, L. (1995) · Optical-Thermal Response of Laser-Irradiated Tissue · doi:10.1007/978-1-4757-6092-7_4 · Cited by 252
Thickness and resistivity variations over the upper surface of the human skull
Law, S. K. (1993) · Brain Topography · doi:10.1007/bf01191074 · Cited by 208
An investigation of light transport through scattering bodies with non-scattering regions
Firbank, M., Arridge, S. R., Schweiger, M., & Delpy, D. T. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/4/012 · Cited by 189
Frequency-domain optical absorption spectroscopy of finite tissue volumes using diffusion theory
Pogue, B. W., & Patterson, M. S. (1994) · Physics in Medicine and Biology · doi:10.1088/0031-9155/39/7/008 · Cited by 184
Hybrid model of Monte Carlo simulation and diffusion theory for light reflectance by turbid media
Wang, L., & Jacques, S. L. (1993) · Journal of the Optical Society of America A · doi:10.1364/josaa.10.001746 · Cited by 181
Zhang, Q., Strangman, G. E., & Ganis, G. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2008.12.048 · Cited by 176
Self-citationTorricelli, A., Pifferi, A., Taroni, P., Giambattistelli, E., & Cubeddu, R. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/8/313 · Cited by 173
Zhang, Q., Brown, E. N., & Strangman, G. E. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2754714 · Cited by 163
Self-citationGRATTON, G., & CORBALLIS, P. M. (1995) · Psychophysiology · doi:10.1111/j.1469-8986.1995.tb02958.x · Cited by 160
Hueber, D. M., Franceschini, M. A., Ma, H. Y., Zhang, Q., Ballesteros, J. R., Fantini, S., Wallace, D., Ntziachristos, V, & Chance, B. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/1/304 · Cited by 158
Self-citationSaager, R. B., & Berger, A. J. (2008) · Journal of Biomedical Optics · doi:10.1117/1.2940587 · Cited by 155
Thickness of the normal skull in the American blacks and whites
Adeloye, A., Kattan, K. R., & Silverman, F. N. (1975) · American Journal of Physical Anthropology · doi:10.1002/ajpa.1330430105 · Cited by 151
Custo, A., Wells, W. M., Barnett, A. H., Hillman, E. M. C., & Boas, D. A. (2006) · Applied Optics · doi:10.1364/ao.45.004747 · Cited by 147
The missing link: analogous human and primate cortical gamma oscillations
Hall, S. D., Holliday, I. E., Hillebrand, A., Singh, K. D., Furlong, P. L., Hadjipapas, A., & Barnes, G. R. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.01.009 · Cited by 138
Zhang, Q., Brown, E. N., & Strangman, G. E. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2804706 · Cited by 132
Self-citationThe Thickness of Human Scalp: Normal and Bald
Hori, H., Moretti, G., Rebora, A., & Crovato, F. (1972) · Journal of Investigative Dermatology · doi:10.1111/1523-1747.ep12540633 · Cited by 115
The effect of overlying tissue on the spatial sensitivity profile of near-infrared spectroscopy
Okada, E., Firbank, M., & Delpy, D. T. (1995) · Physics in Medicine and Biology · doi:10.1088/0031-9155/40/12/007 · Cited by 106
Hasan, K. M., Sankar, A., Halphen, C., Kramer, L. A., Brandt, M. E., Juranek, J. J., Cirino, P. T., Fletcher, J. M., Papanicolaou, A. C., & Ewing‐Cobbs, L. (2007) · Neuroreport · doi:10.1097/wnr.0b013e3282f0d40c · Cited by 104
Li, T., Gong, H., & Luo, Q. (2011) · Journal of Biomedical Optics · doi:10.1117/1.3567085 · Cited by 99
Cui, W., & Ostrander, L. E. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.121651 · Cited by 64
Mansouri, C., L’Huillier, J.-P., Kashou, N. H., & Humeau‐Heurtier, A. (2010) · Lasers in Medical Science · doi:10.1007/s10103-010-0754-4 · Cited by 63
Li, H., Ruan, J., Xie, Z., Wang, H., & Liu, W. (2007) · International Journal of Vehicle Safety · doi:10.1504/ijvs.2007.016747 · Cited by 55
Babiloni, F., Babiloni, C., Carducci, F., Gaudio, M. D., Onorati, P., & Urbano, A. (1997) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(97)00035-7 · Cited by 31
Significance of tissue anisotropy in optical tomography of the infant brain
Heiskala, J., Neuvonen, T., Grant, P. E., & Nissila, I. T. (2007) · Applied Optics · doi:10.1364/ao.46.001633 · Cited by 15
Cited by
Pinti, P., Tachtsidis, I., Hamilton, A., Hirsch, J., Aichelburg, C., Gilbert, S., & Burgess, P. W. (2020) · Annals of the New York Academy of Sciences · doi:10.1111/nyas.13948 · Cited by 1,336
Zimeo Morais, G. A., Balardin, J. B., & Sato, J. R. (2018) · Scientific Reports · doi:10.1038/s41598-018-21716-z · Cited by 375
Brigadoi, S., & Cooper, R. J. (2015) · Neurophotonics · doi:10.1117/1.nph.2.2.025005 · Cited by 328
Prefrontal cortex and executive function in young children: a review of NIRS studies
Moriguchi, Y., & Hiraki, K. (2013) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2013.00867 · Cited by 288
“Nevertheless, more recent research has shown that the depth sensitivity at a depth of around 1 cm into the intracranial space is quite low by the thickness of several overlying tissue layers, such as scalp (Strangman et al., 2013).”
BackgroundMethodMulti-wavelength photoplethysmography method for skin arterial pulse extraction
Liu, J., Yan, B. P.-Y., Dai, W.-X., Ding, X.-R., Zhang, Y.-T., & Zhao, N. (2016) · Biomedical Optics Express · doi:10.1364/boe.7.004313 · Cited by 107
Metadata
- Authors
- Strangman, G. E., Li, Z., & Zhang, Q.
- Venue
- PLoS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2013-08-01
- Volume
- 8
- Issue
- 8
- Pages
- e66319
- ISSN
- 1932-6203 (ISSN-L)
- OpenAlex
- W2125956101
- Cited by
- 262
- References
- 49
- FWCI
- 7.37
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.