Neurological Tremor: Sensors, Signal Processing and Emerging Applications
Open accessThe DOI matches its Crossref record; 78 of the 82 references it cites were found in a registry or an index; 2 of the 70 sources its claims cite were checked for support.
Abstract
Neurological tremor is the most common movement disorder, affecting more than 4% of elderly people. Tremor is a non linear and non stationary phenomenon, which is increasingly recognized. The issue of selection of sensors is central in the characterization of tremor. This paper reviews the state-of-the-art instrumentation and methods of signal processing for tremor occurring in humans. We describe the advantages and disadvantages of the most commonly used sensors, as well as the emerging wearable sensors being developed to assess tremor instantaneously. We discuss the current limitations and the future applications such as the integration of tremor sensors in BCIs (brain-computer interfaces) and the need for sensor fusion approaches for wearable solutions.
Overview
CoChat Summary
## TL;DR
This review surveys sensors and signal-processing methods used to characterize neurological tremor, emphasizing accelerometers, EMG, and emerging wearable/MEMS solutions. It argues that clinical usefulness depends on sensors that are stable, lightweight, and correlated with clinical and functional scores, with sensor fusion and BCI applications highlighted as future directions.
## Key findings
- Neurological tremor affects “more than 4%” of people older than 65 years, and more than two-thirds of people with upper-limb tremor face serious daily-life difficulties.
- The paper identifies accelerometers and EMG as the most commonly used tools for tremor assessment, while noting that wearable sensors, MEMS devices, and hybrid/sensor-fusion approaches are expanding quickly.
- Accelerometers are described as simple and relatively reliable for measuring oscillation frequency and amplitude, but they cannot directly separate linear acceleration from gravity and require calibration.
- The paper notes reported associations between instrumentation and clinical use cases, including:
- accelerometers for estimating Parkinson’s disease symptom severity and for intra-operative DBS electrode placement,
- long-term EMG as a valid and reliable method for quantifying pathological tremor and classifying parkinsonian versus essential tremor,
- haptic/force-sensor devices achieving “high accuracy” in reproducibility of frequency and amplitudes of imposed oscillations.
- For signal processing, the review lists common tremor descriptors such as peak frequency, median frequency, PSD in the 1–20 Hz and 1–33 Hz bands, crest factor, harmonic index, and frequency dispersion; it also highlights wavelets, FFT, autoregression, and EMD as useful methods for nonstationary tremor signals.
## Methods
- This is a narrative review of the state of the art in tremor instrumentation and signal processing; no original experimental sample or dataset is reported.
- The paper synthesizes published evidence on sensors (EMG, accelerometers, gyroscopes, goniometers, video, force sensors, wearable orthoses, optoelectronic devices) and on signal-processing approaches (editing, filtering, spectral estimation, wavelets, cross-spectrum/coherence).
- The analysis is descriptive/comparative, focusing on advantages, disadvantages, and proposed applications rather than a formal meta-analysis.
## Limitations
- The paper states that several future studies are still required, including better sensor fusion approaches for wearable solutions, reliable/stable hybrid sensors, and integration of sensors and actuators into comfortable textiles.
- It also explicitly notes practical limitations of current methods: accelerometers need calibration and cannot distinguish gravity from acceleration without a validated model; video analysis can be time-consuming; haptic devices can be nonportable and expensive; wearable orthoses face aesthetic/cosmetic and affordability issues.
- Evident from the text: no systematic review protocol, search strategy, inclusion criteria, or quantitative synthesis is described, so the review’s scope and completeness cannot be assessed from the paper itself.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Figures









Verification
Claims the paper makes
2 Valid · 1 Not valid · 56 Not checked · 14 Own results and interpretations
Every source the paper cites for this claim was checked and supports it.
In the paper
“The feasibility of using data recorded with accelerometers to estimate the severity of symptoms and motor complications in patients with Parkinson’s disease has been shown recently [27].”
§ Neurological Tremor: Sensors, Signal Processing and Emerging Applications > Sensors and Instrumentation for the Characterization of Tremor > Accelerometers
What the sources say
- Supportedcites [27] Patel, 2009, Monitoring motor fluctuations in patients with Parkinson’s disease using wearable sensors, IEEE Trans. Inf. Technol. Biomed source
The Discussion and Conclusions states that the study estimated tremor, bradykinesia, and dyskinesia severity from accelerometer data. The Results section reports estimation-error analyses for those clinical scores, supporting the claimed feasibility in patients with Parkinson’s disease. Page numbers are not provided in our copy. (LLM, conf=0.94)
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
Every source the paper cites for this claim was checked and supports it.
In the paper
“Data from accelerometers are composed of a combination of linear acceleration, gravity, and additive noise [16].”
§ Neurological Tremor: Sensors, Signal Processing and Emerging Applications > Sensors and Instrumentation for the Characterization of Tremor > Accelerometers
What the sources say
- Supportedcites [16] Luinge, 2005, Measuring orientation of human body segments using miniature gyroscopes and accelerometers, Med. Biol. Eng. Comput source
Section 2.2 models accelerometer signals as linear acceleration, a gravity contribution, and additive white Gaussian measurement noise. The gravity term is subtracted under the paper’s sign convention, but this supports the claim that all three contribute to the signal. (LLM, conf=0.95)
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
In the paper
“Measuring devices based on video imaging are effective in quantifying motor impairments in clinical settings [34].”
§ Neurological Tremor: Sensors, Signal Processing and Emerging Applications > Sensors and Instrumentation for the Characterization of Tremor > Videos
What the sources say
- Not checked — no full text of the sourcecites [34] Swider, 1998, The application of video image processing to quantitative analysis of extremity tremor in humans, J. Neurosci. Methods source
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
In the paper
“Recent works indicate that these recordings allow a rater-independent classification of parkinsonian versus essential tremor [23].”
§ Neurological Tremor: Sensors, Signal Processing and Emerging Applications > Sensors and Instrumentation for the Characterization of Tremor > Electromyography (EMG)
What the sources say
- Not checked — no full text of the sourcecites [23] Breit, 2008, Long-term EMG recordings differentiate between parkinsonian and essential tremor, J. Neurol source
hedgedstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
In the paper
“However, the videotaped motor examination may present some limitations when patients have mild symptoms [35].”
§ Neurological Tremor: Sensors, Signal Processing and Emerging Applications > Sensors and Instrumentation for the Characterization of Tremor > Videos
What the sources say
- Not checked — no full text of the sourcecites [35] Louis, 2002, Diagnosing Parkinson’s disease using videotaped neurological examinations: validity and factors that contribute to incorrect diagnoses, Mov. Disord source
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
22 more claims
Create a free account to see all 73 claims and every source verdict.
- Probably not a substantial claim. 32
- It may state two separate claims as one. 25
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“However, kinematic data have been shown to lack precision since they are affected by increased segment acceleration or the presence of drifts (algorithms have been developed to decrease the effect of drifting in accelerometers) [4,5,6].”
From Validity and Reliability of Wearable Sensors for Joint Angle Estimation: A Systematic Review (2019) · cites this paper as [4]
Experimental — accuracy not yet measured
Citations
Cites
Adult Norms for the Box and Block Test of Manual Dexterity
Mathiowetz, V., Volland, G., Kashman, N., & Weber, K. (1985) · The American Journal of Occupational Therapy · doi:10.5014/ajot.39.6.386 · Cited by 2,105 · cited 1×
“C-TES (Clinical-TES) Anamnesis Assessment of disability (Activities of Daily Living scales / ADL-T24) Physical and Neurological examination Tremor evaluation - Body segments involved (head, trunk, upper limbs, lower limbs) - Enhancing/reducing effect (effect of mental calculation/contralateral contractions) - Distribu…”
MethodConsensus Statement of the Movement Disorder Society on Tremor
Deuschl, G., Bain, P., & Brin, M. (2008) · Movement Disorders · doi:10.1002/mds.870131303 · Cited by 1,981
Human movement analysis using stereophotogrammetry
Leardini, A., Chiari, L., Croce, U. D., & Cappozzo, A. (2005) · Gait & Posture · doi:10.1016/j.gaitpost.2004.05.002 · Cited by 1,239 · cited 3×
“…axis of hips, knees and ankles can be determined reliably, but motion about other axes at those joints should be interpreted cautiously, as the soft tissue artefact produces spurious effects with amplitudes comparable to the amount of motion actually occurring in those joints [46].”
BackgroundInfluentialWhat is the Bereitschaftspotential?
Shibasaki, H., & Hallett, M. (2006) · Clinical Neurophysiology · doi:10.1016/j.clinph.2006.04.025 · Cited by 1,169 · cited 2×
“The early BP might reflect slowly increasing cortical excitability and subconscious readiness for the forthcoming movement [64].”
BackgroundAdult Norms for the Nine Hole Peg Test of Finger Dexterity
Mathiowetz, V., Weber, K., Kashman, N., & Volland, G. (1985) · The Occupational Therapy Journal of Research · doi:10.1177/153944928500500102 · Cited by 972 · cited 1×
“C-TES (Clinical-TES) Anamnesis Assessment of disability (Activities of Daily Living scales / ADL-T24) Physical and Neurological examination Tremor evaluation - Body segments involved (head, trunk, upper limbs, lower limbs) - Enhancing/reducing effect (effect of mental calculation/contralateral contractions) - Distribu…”
MethodMeasuring orientation of human body segments using miniature gyroscopes and accelerometers
Luinge, H. J., & Veltink, P. H. (2005) · Medical & Biological Engineering & Computing · doi:10.1007/bf02345966 · Cited by 647 · cited 1×
“Data from accelerometers are composed of a combination of linear acceleration, gravity, and additive noise [16].”
BackgroundMonitoring Motor Fluctuations in Patients With Parkinson's Disease Using Wearable Sensors
Patel, S., Lorincz, K., Hughes, R., Huggins, N., Growdon, J., Standaert, D., Akay, M., Dy, J., Welsh, M., & Bonato, P. (2009) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2009.2033471 · Cited by 623 · cited 1×
“The feasibility of using data recorded with accelerometers to estimate the severity of symptoms and motor complications in patients with Parkinson's disease has been shown recently [27].”
MethodRoetenberg, D., Luinge, H. J., Baten, C. T. M., & Veltink, P. H. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.847353 · Cited by 588 · cited 1×
“Low-pass filtering is commonly used [25].”
Human movement analysis using stereophotogrammetry
Chiari, L., Croce, U. D., Leardini, A., & Cappozzo, A. (2005) · Gait & Posture · doi:10.1016/j.gaitpost.2004.04.004 · Cited by 441 · cited 4×
“Recognition of passive markers can be performed either via recognition software or with a dedicated hardware circuit [42-44].”
BackgroundMethodInfluentialSalarian, A., Russmann, H., Wider, C., Burkhard, P. R., Vingerhoets, F. J. G., & Aminian, K. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.886670 · Cited by 416 · cited 1×
“Flexible angular sensors are commonly used in rehabilitation and sports, but have not been disseminated at a large scale for studies of tremor [8,31,32].”
BackgroundHuman movement analysis using stereophotogrammetryPart 1: theoretical background
CAPPOZZO, A., DELLACROCE, U., LEARDINI, A., & CHIARI, L. (2005) · Gait & Posture · doi:10.1016/s0966-6362(04)00025-6 · Cited by 398
Wearable sensors/systems and their impact on biomedical engineering
Bonato, P. (2003) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2003.1213622 · Cited by 382 · cited 1×
“The field of wearable sensors in bioengineering applications and medicine is growing rapidly [52].”
BackgroundStacy, M. A., Elble, R. J., Ondo, W. G., Wu, S., Hulihan, J., & TRS Study Group (2007) · Movement Disorders · doi:10.1002/mds.21412 · Cited by 296
McAuley, J. H., Rothwell, J. C., & Marsden, C. D. (1997) · Experimental Brain Research · doi:10.1007/pl00005662 · Cited by 285 · cited 1×
“For human tremor applications, the following parameters are extracted [71-73]: -spectrum shape with identification of single or multiple peaks -peak frequency -median frequency -power spectral density (PSD), in particular in the band 1–20 Hz (PSD 1-20Hz ) and 1–33 Hz (PSD 1-33Hz ), with…”
MethodElble, R. J. (1996) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199603000-00004 · Cited by 271 · cited 1×
“It occurs in healthy individuals as the so-called physiological tremor, which is composed of two distinct oscillations (mechanical reflex and central neurogenic) superimposed on a background of irregular fluctuations in muscle forces and displacements [4,5].”
BackgroundDaube, J. R., & Rubin, D. I. (2009) · Muscle & Nerve · doi:10.1002/mus.21180 · Cited by 243
Clinical Applications of Sensors for Human Posture and Movement Analysis: A Review
Wong, W. Y., Wong, M. S., & Lo, K. H. (2007) · Prosthetics & Orthotics International · doi:10.1080/03093640600983949 · Cited by 193 · cited 4×
“Impedance, signal level, effects of gravitational component and cost are some important parameters related to this technique [15].”
BackgroundMethodInfluential(1995) · M. Dekker eBooks · Cited by 171
Characteristics of physiologic tremor in young and elderly adults
Elble, R. J. (2003) · Clinical Neurophysiology · doi:10.1016/s1388-2457(03)00006-3 · Cited by 163 · cited 1×
“It occurs in healthy individuals as the so-called physiological tremor, which is composed of two distinct oscillations (mechanical reflex and central neurogenic) superimposed on a background of irregular fluctuations in muscle forces and displacements [4,5].”
BackgroundSporadic ataxias in Japan – a population-based epidemiological study
Tsuji, S., Onodera, O., Goto, J., Nishizawa, M., & On Behalf of the Study Group on Ataxic Diseases* (2008) · The Cerebellum · doi:10.1007/s12311-008-0028-x · Cited by 160
Reliability between two observers using a protocol for diagnosing essential tremor
Louis, E. D., Ford, B., & Bismuth, B. (1998) · Movement Disorders · doi:10.1002/mds.870130215 · Cited by 150 · cited 1×
“Experimental procedures for assessment of tremor as well as validation of new methods benefit from videotaping [36-37].”
MethodLouis, E. D., Marder, K., Cote, L., Pullman, S., Ford, B., Wilder, D., Tang, M.-X., Lantigua, R., Gurland, B., & Mayeux, R. (1995) · Archives of Neurology · doi:10.1001/archneur.1995.00540360079019 · Cited by 149 · cited 1×
“Its incidence and prevalence increase with ageing, affecting more than 4% of the patients older than 65 years [1].”
BackgroundLin, C.-T., Ko, L.-W., Chang, M.-H., Duann, J.-R., Chen, J.-Y., Su, T.-P., & Jung, T.-P. (2010) · Gerontology · doi:10.1159/000230807 · Cited by 133 · cited 1×
“A different approach to the direct measurement of trembling legs or arms is to use the EEG signal in the framework of a Brain Computer Interface (BCI) [62].”
MethodA teaching videotape for the assessment of essential tremor
Louis, E. D., Barnes, L., Wendt, K. J., Ford, B., Sangiorgio, M., Tabbal, S., Lewis, L., Kaufmann, P., Moskowitz, C., Comella, C. L., et al. (2001) · Movement Disorders · doi:10.1002/1531-8257(200101)16:1<89::aid-mds1001>3.0.co;2-l · Cited by 121
Balance and motor speech impairment in essential tremor
Kronenbuerger, M., Konczak, J., Ziegler, W., Buderath, P., Frank, B., Coenen, V. A., Kiening, K., Reinacher, P., Noth, J., & Timmann, D. (2009) · The Cerebellum · doi:10.1007/s12311-009-0111-y · Cited by 118 · cited 1×
“Essential tremor is the commonest cause [9].”
Attitude and gyro bias estimation for a VTOL UAV
Metni, N., Pflimlin, J.-M., Hamel, T., & Souères, P. (2006) · Control Engineering Practice · doi:10.1016/j.conengprac.2006.02.015 · Cited by 110 · cited 2×
“Low-cost ‘‘strap down’’ gyroscopes are now internally compensated in temperature and therefore the bias vector slowly oscillates around a constant average value [30].”
BackgroundLesion-Symptom Mapping of the Human Cerebellum
Timmann, D., Brandauer, B., Hermsdörfer, J., Ilg, W., Konczak, J., Gerwig, M., Gizewski, E. R., & Schoch, B. (2008) · The Cerebellum · doi:10.1007/s12311-008-0066-4 · Cited by 107 · cited 1×
“Detailed lesion-mapping studies have now delineated the regions of the cerebellum that cause deficits in limbs or trunk [11].”
BackgroundInertial measurements of upper limb motion
Zhou, H., Hu, H., & Tao, Y. (2006) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-006-0063-z · Cited by 106 · cited 1×
“Flexible angular sensors are commonly used in rehabilitation and sports, but have not been disseminated at a large scale for studies of tremor [8,31,32].”
BackgroundIdentification of psychogenic, dystonic, and other organic tremors by a coherence entrainment test
McAuley, J., & Rothwell, J. (2004) · Movement Disorders · doi:10.1002/mds.10707 · Cited by 101 · cited 1×
“Interestingly, tremor recordings during a tapping exercise with the controlateral arm provide a quantified electrophysiological entrainment test which is a sensitive and specific procedure to distinguish psychogenic tremor from dystonic and other organic tremors [22].”
BackgroundInfluence of alcohol on gait in patients with essential tremor
Klebe, S., Stolze, H., Grensing, K., Volkmann, J., Wenzelburger, R., & Deuschl, G. (2005) · Neurology · doi:10.1212/01.wnl.0000167550.97413.1f · Cited by 99 · cited 1×
“Most optoelectronic devices use reflective (passive) or active markers (such as infra-red light emitting diodes LEDs) fixed on anatomical landmarks of the body, such as bone landmarks [39,40].”
BackgroundAdaptive mode tuning for vibrational gyroscopes
Leland, R. P. (2003) · IEEE Transactions on Control Systems Technology · doi:10.1109/tcst.2003.809240 · Cited by 99 · cited 1×
“Several control algorithms have been proposed, including a sliding mode control with a force balancing control strategy and an adaptative controller for tuning the natural frequency of the drive axis of a vibratory gyroscope [58-60].”
MethodSliding mode control of a simulated MEMS gyroscope
Batur, C., Sreeramreddy, T., & Khasawneh, Q. (2006) · ISA Transactions · doi:10.1016/s0019-0578(07)60069-x · Cited by 98
Estimation of Upper-Limb Orientation Based on Accelerometer and Gyroscope Measurements
Hyde, R. A., Ketteringham, L. P., Neild, S. A., & Jones, R. J. S. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.912647 · Cited by 98 · cited 1×
“Estimation of upper-limb orientation using miniature accelerometers and gyroscopes is accurate and renders the measurement system less obtrusive [66].”
BackgroundA novel adaptive sliding mode control with application to MEMS gyroscope
Fei, J., & Batur, C. (2009) · ISA Transactions · doi:10.1016/j.isatra.2008.10.008 · Cited by 97 · cited 2×
“…proportional-integral sliding mode adaptative control proposed by Fei and Batur takes into account both matched and unmatched uncertainties and shows consistent estimation of gyroscope parameters including angular velocity and large robustness to parameter variations and external disturbances [57].”
BackgroundDietz, V., Hillesheimer, W., & Freund, H. J. (1974) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.37.8.927 · Cited by 94 · cited 1×
“Participating motor units usually discharge at about 8–13 Hz [6].”
BackgroundPostural and resting tremor in the upper limb
Morrison, S., & Newell, K. M. (2000) · Clinical Neurophysiology · doi:10.1016/s1388-2457(99)00302-8 · Cited by 92 · cited 1×
“Various levels of support of the limbs have been proposed [26].”
BackgroundPattern recognition in 3D automatic human motion analysis
Ferrigno, G., Borghese, N. A., & Pedotti, A. (1990) · ISPRS Journal of Photogrammetry and Remote Sensing · doi:10.1016/0924-2716(90)90046-e · Cited by 86
Braune, W., & Fischer, O. (1987) · Springer eBooks · doi:10.1007/978-3-642-70326-3 · Cited by 79 · cited 1×
“The estimation of three-dimensional positioning from digitized data is based on the geometrical properties of a central projection [41].”
MethodMagnetic resonance imaging in spinocerebellar ataxias
Döhlinger, S., Hauser, T., Borkert, J., Luft, A. R., & Schulz, J. B. (2008) · The Cerebellum · doi:10.1007/s12311-008-0025-0 · Cited by 71 · cited 1×
“Concerning imaging, brain MRI has become a routine procedure in the evaluation and follow-up of neurological patients [12].”
Quantification of the drawing of an Archimedes spiral through the analysis of its digitized picture
Miralles, F., Tarongí, S., & Espino, A. (2006) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.08.007 · Cited by 70 · cited 1×
“Quantification of drawings of Archimedes’ spiral is either based on the off-line analysis of the digitized picture obtained from a commercial scanner [51], or from data collected from one or two accelerometers fixed on the pen.”
MethodMechanical suppression of essential tremor
Rocon, E., Manto, M., Pons, J., Camut, S., & Belda, J. M. (2007) · The Cerebellum · doi:10.1080/14734220601103037 · Cited by 68 · cited 2×
“Although tremor is not life-threatening, it causes functional disability and social inconvenience, contaminating daily life activities, such as writing, pouring, eating, and so on [2].”
BackgroundSelf-citationTremor analysis in two normal cohorts
Raethjen, J., Lauk, M., Köster, B., Fietzek, U. M., Friege, L., Timmer, J., Lücking, C. H., & Deuschl, G. (2004) · Clinical Neurophysiology · doi:10.1016/j.clinph.2004.04.006 · Cited by 66
Rest and postural tremors in patients with Parkinson's disease
Duval, C. (2006) · Brain Research Bulletin · doi:10.1016/j.brainresbull.2005.11.010 · Cited by 63 · cited 1×
“For human tremor applications, the following parameters are extracted [71-73]: -spectrum shape with identification of single or multiple peaks”
MethodLong-term EMG recordings differentiate between parkinsonian and essential tremor
Breit, S., Spieker, S., Schulz, J. B., & Gasser, T. (2008) · Journal of Neurology · doi:10.1007/s00415-008-0712-2 · Cited by 63 · cited 1×
“Recent works indicate that these recordings allow a rater-independent classification of parkinsonian versus essential tremor [23].”
BackgroundBraune, W., & Fischer, O. (1987) · Medical Entomology and Zoology · Cited by 60
An automated motion measurement system for clinical gait analysis
Taylor, K. D., Mottier, F. M., Simmons, D. W., Cohen, W. W., Pavlak, R., Cornell, D. P., & Hankins, G. B. (1982) · Journal of Biomechanics · doi:10.1016/0021-9290(82)90004-5 · Cited by 53
New Adaptive Mode of Operation for MEMS Gyroscopes
Park, S., & Horowitz, R. (2004) · Journal of Dynamic Systems, Measurement, and Control · doi:10.1115/1.1849252 · Cited by 52 · cited 1×
“Several control algorithms have been proposed, including a sliding mode control with a force balancing control strategy and an adaptative controller for tuning the natural frequency of the drive axis of a vibratory gyroscope [58-60].”
MethodIdentification of task parameters from movement-related cortical potentials
Gu, Y., do Nascimento, O. F., Lucas, M.-F., & Farina, D. (2009) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-009-0523-3 · Cited by 51 · cited 4×
“Pattern recognition techniques have been proposed for the classification of single-trial MRCPs, based upon optimization of wavelets and support vector machine (SVM) [63].”
BackgroundInfluentialManto, M. U., & Marmolino, D. (2009) · The Cerebellum · doi:10.1007/s12311-009-0127-3 · Cited by 47 · cited 1×
“There are also applications outside human disorders, for instance in animal models of tremor [29].”
BackgroundSelf-citationSpinocerebellar ataxias caused by polyglutamine expansions: A review of therapeutic strategies
Underwood, B. R., & Rubinsztein, D. C. (2008) · The Cerebellum · doi:10.1007/s12311-008-0026-z · Cited by 44 · cited 1×
“The need for reliable sensors will increase in the future, because new therapeutic strategies for disorders previously considered as not treatable are emerging [75,76].”
BackgroundLouis, E. D., Levy, G., Côte, L. J., Mejia, H., Fahn, S., & Marder, K. (2002) · Movement Disorders · doi:10.1002/mds.10119 · Cited by 41 · cited 1×
“However, the videotaped motor examination may present some limitations when patients have mild symptoms [35].”
BackgroundIndexes for identification of abnormal tremor using computer tremor evaluation systems
Edwards, R., & Beuter, A. (1999) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.771207 · Cited by 38 · cited 1×
“For human tremor applications, the following parameters are extracted [71-73]: -spectrum shape with identification of single or multiple peaks -peak frequency -median frequency -power spectral density (PSD), in particular in the band 1–20 Hz (PSD 1-20Hz ) and 1–33 Hz (PSD 1-33Hz ), with…”
MethodMaterial Fatigue and Reliability of MEMS Accelerometers
Xiong, X., Wu, Y.-L., & Jone, W.-B. (2008) · 2008 IEEE International Symposium on Defect and Fault Tolerance of VLSI Systems · doi:10.1109/dft.2008.37 · Cited by 33 · cited 1×
“However, because most of MEMS devices contain movable parts, material fatigue and aging under long-term repeated cycling load may cause potential device failure, which in turn decreases the device reliability [56].”
BackgroundPellegrini, B., Faes, L., Nollo, G., & Schena, F. F. (2004) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.04.025 · Cited by 31 · cited 1×
“Most optoelectronic devices use reflective (passive) or active markers (such as infra-red light emitting diodes LEDs) fixed on anatomical landmarks of the body, such as bone landmarks [39,40].”
BackgroundTremor: From Pathogenesis to Treatment
Grimaldi, G., & Manto, M. (2008) · Synthesis Lectures on Biomedical Engineering · doi:10.1007/978-3-031-01627-1 · Cited by 28 · cited 9×
“Rest tremor frequency is typically in the 3–6 Hz frequency range [7,8] and may increase with mental stress ( i.e. , counting backwards) or contralateral voluntary motion [8].”
BackgroundMethodInfluentialSelf-citationIntraoperative neurophysiological assessment of disabling symptoms in DBS surgery
Journee, H. L., Postma, A. A., & Staal, M. J. (2007) · Neurophysiologie Clinique/Clinical Neurophysiology · doi:10.1016/j.neucli.2007.10.006 · Cited by 27 · cited 1×
“Accelerometers are also used for intra-operative assessment of the best position to implant electrodes for deep brain stimulation (DBS) and neurophysiological monitoring of stereotactic intervention of movement disorders [28].”
MethodComparative assessment of two algorithms for calibrating stereophotogrammetric systems
Gazzani, F. (1993) · Journal of Biomechanics · doi:10.1016/0021-9290(93)90095-v · Cited by 26 · cited 1×
“Calibration inaccuracies, image distortion, electrical noise, errors in positioning of markers and marker flickering (imprecision related to image conversion), as well as experimental mistakes related to the selection of the environment may occur [42,45].”
BackgroundEffect of medication in Parkinson’s disease: a wavelet analysis of EMG signals
Strambi, S.-K., Rossi, B., De Michele, G., & Sello, S. (2004) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2004.01.006 · Cited by 22 · cited 1×
“Wavelet transforms co-localize in both frequency domain and time domain and are effective for non stationary signals such as neurological tremor [70].”
BackgroundQuantitative Assessment of Neuromotor Function in Workers With Current Low Exposure to Mercury Vapor
Wastensson, G., Lamoureux, D., Sällsten, G., et al. (2007) · NeuroToxicology · doi:10.1016/j.neuro.2008.03.005 · Cited by 19 · cited 1×
“Both the clinical examination and quantification of tremor should be performed by the same examiner if possible, in order to reduce the anxiety effect, which may cause noticeable differences in results [18].”
BackgroundTimmann, D., Lee, P., Watts, S., & Hore, J. (2008) · The Cerebellum · doi:10.1007/s12311-008-0037-9 · Cited by 19 · cited 1×
“Their main clinical application remains the assessment or upper limb kinematics [55].”
BackgroundApplication of EMD as a novel technique for the study of tremor time series
Rocon, E., Pons, J. L., Andrade, A. O., & Nasuto, S. J. (2006) · 2006 International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2006.260871 · Cited by 19 · cited 1×
“Second, the empirical mode decomposition (EMD) can be used to isolate tremor movements from non oscillatory movements [74].”
MethodTremor Suppression Using Smart Textile Fibre Systems
Wang, L. (2008) · Journal of Fiber Bioengineering and Informatics · doi:10.3993/jfbi03200902 · Cited by 18 · cited 2×
“Active and semi-active control devices have been proposed to suppress oscillations [54].”
BackgroundBioinformatic Approaches Used in Modelling Human Tremor
Mario, M., Giuliana, G., Thomas, L., Dario, F., Lana, P., Silvia, C., Tommaso, D., Juan-Manuel, B.-L., Jose-Luis, P., & Eduardo, R. (2009) · Current Bioinformatics · doi:10.2174/157489309788184747 · Cited by 17 · cited 2×
“Editing remains a critical step in digital processing of tremor series [8,67,68].”
BackgroundA recording and analysis system for human tremor
Engin, M. (2007) · Measurement · doi:10.1016/j.measurement.2006.05.015 · Cited by 16 · cited 2×
“The FFT is the most popular method to perform transformation in the frequency domain, being computationally simple and fast [24].”
BackgroundMethodThe highly heterogeneous spinocerebellar ataxias: From genes to targets for therapeutic intervention
Matilla-Dueñas, A. (2008) · The Cerebellum · doi:10.1007/s12311-008-0020-5 · Cited by 15 · cited 1×
“The need for reliable sensors will increase in the future, because new therapeutic strategies for disorders previously considered as not treatable are emerging [75,76].”
BackgroundRozman, J., Bartolić, A., & Ribarič, S. (2007) · Journal of Medical Engineering & Technology · doi:10.1080/03091900600992064 · Cited by 13 · cited 1×
“Rozman et al. have developed a method based on force transducers to evaluate rest tremor of the wrist and metacarpophalangeal joints in two degrees of freedom for each joint [50].”
MethodJournée, H. L., Postma, A. A., Sun, M., & Staal, M. J. (2008) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2006.12.005 · Cited by 13 · cited 2×
“Editing remains a critical step in digital processing of tremor series [8,67,68].”
BackgroundMethodOptimizing deep brain stimulation settings using wearable sensing technology
Patel, S., Mancinelli, C., Hughes, R. L., Dalton, A. F., Shih, L. C., & Bonato, P. (2009) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2009.5109221 · Cited by 13 · cited 1×
“Parkinson’s disease is a typical disorder under investigation [53].”
BackgroundReply to Johnson E. Needle Electromyography MUS 2009; 40(4)
Rubin, D. I., & Daube, J. R. (2009) · Muscle & Nerve · doi:10.1002/mus.21417 · Cited by 12
Grimaldi, G., Lammertse, P., Van Den Braber, N., Meuleman, J., & Manto, M. (2008) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2008.926726 · Cited by 11 · cited 1×
“…angular motion, torques and corresponding EMG activities (in case of combination with EMG sensors), and can be used to obtain real-time spectral analysis, to apply loads and mechanical oscillations as well as characterize the effects of damping on voluntary motion in neurological patients [48].”
BackgroundSelf-citationThe application of video image processing to quantitative analysis of extremity tremor in humans
Świder, M. (1998) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(98)00111-3 · Cited by 11 · cited 1×
“Measuring devices based on video imaging are effective in quantifying motor impairments in clinical settings [34].”
Background(1999) · PubMed · Cited by 11
Tracking Tremor Frequency in Spike Trains Using the Extended Kalman Filter
Kim, S., & McNames, J. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2005.1616265 · Cited by 10 · cited 1×
“Alternatives include the use of extended Kalman filter (EKF) to estimate the instantaneous tremor frequency, as applied in spike trains detected from microelectrode recordings [69].”
MethodGrimaldi, G., Lammertse, P., & Manto, M. U. (2007) · IEEE/EMBS International Summer School on Medical Devices and Biosensors (ISSS-MDBS) · doi:10.1109/issmdbs.2007.4338288 · Cited by 7
Self-citationBrunetti, F. J., Rocon, E., Pons, J. L., & Manto, M. (2005) · The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2004.1403090 · Cited by 6 · cited 1×
“Wireless inertial sensor with the combination of different types of sensors (for instance three linear accelerometers, three gyroscopes and three magnetometers [61]) is now being applied.”
MethodSelf-citationUnifying hypothesis for the motoneuronal code in neurological disorders
Manto, M., Sauvage, C., & Roark, R. M. (2008) · Bioscience Hypotheses · doi:10.1016/j.bihy.2008.02.011 · Cited by 5 · cited 1×
“Patterns of motoneuronal discharges might constitute “motoneuronal signatures” which takes into account the size of the recruited motor units, the timing of their respective firings, their firing rates and their modulation [21].”
BackgroundSelf-citationLocalization of a Tremor Generator
Safronov, V. A., Shevelev, I. N., Shabalov, V. A., & Panin, V. V. (2001) · Human Physiology · doi:10.1023/a:1010966904144 · Cited by 2 · cited 2×
“The issue of the localization of tremor generators remains central in the field of tremor research [19].”
BackgroundEvaluation of Mucuna utilis germplasm for higher biomass production, L-DOPA and seed yield.
Mamatha, B., Siddaramappa, R., & Shivananda, T. N. (2008) · IEEE Transactions on Biomedical Engineering · Cited by 2
Cited by
Validity and Reliability of Wearable Sensors for Joint Angle Estimation: A Systematic Review
Poitras, I., Dupuis, F., Bielmann, M., Campeau-Lecours, A., Mercier, C., Bouyer, L., & Roy, J.-S. (2019) · Sensors · doi:10.3390/s19071555 · Cited by 309
“This is explained by the movement artifacts added to the acceleration signals, which no longer allow consideration of the Z axis as pure gravity acceleration [4].”
BackgroundLiao, L.-D., Chen, C.-Y., Wang, I.-J., Chen, S.-F., Li, S.-Y., Chen, B.-W., Chang, J.-Y., & Lin, C.-T. (2012) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-9-5 · Cited by 258
“The brain-computer interface (BCI) technique has become a major tool that provides a direct communication pathway between the brain and the external world by translating signals from brain activities into machine codes or commands [2-5].”
BackgroundLópez-de-Ipiña, K., Alonso, J.-B., Travieso, C., Solé-Casals, J., Egiraun, H., Faundez-Zanuy, M., Ezeiza, A., Barroso, N., Ecay-Torres, M., Martinez-Lage, P., et al. (2013) · Sensors · doi:10.3390/s130506730 · Cited by 190
“Particularly, because they do not require specialized personnel or laboratory equipment, so that anyone in the habitual environment of the patient could perform (after proper training) without altering or blocking the patient’s abilities [14–19].”
BackgroundTowards remote monitoring of Parkinson’s disease tremor using wearable motion capture systems
Delrobaei, M., Memar, S., Pieterman, M., Stratton, T. W., McIsaac, K., & Jog, M. (2017) · Journal of the Neurological Sciences · doi:10.1016/j.jns.2017.11.004 · Cited by 120
“Accelerometers function by combining linear acceleration data, which may include gravity and additive noise, to measure the amplitude of oscillations of individual body segments [3], [13], [14].”
InfluentialRoh, E., Lee, H., Kim, D., & Lee, N. (2017) · Advanced Materials · doi:10.1002/adma.201703004 · Cited by 96
Metadata
- Authors
- Grimaldi, G., & Manto, M.
- Affiliations
- FNRS, Neurologie ULB-Erasme, 808 Route de Lennik, 1070 Bruxelles, Belgium
- Corresponding author
- Manto, Mario
- ORCID
- Manto, Mario
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2010-02-24
- Volume
- 10
- Issue
- 2
- Pages
- 1399-1422
- ISSN
- 1424-8220 (ISSN-L)
- PMC
- PMC3244020
- OpenAlex
- W2123354643
- Cited by
- 138
- References
- 82
- Citations by year
- 2026: 4 · 2025: 5 · 2024: 5 · 2023: 7 · 2022: 12 · 2021: 17 · 2020: 19 · 2019: 8 · 2018: 7 · 2017: 12 · 2016: 10 · 2015: 5 · 2014: 7 · 2013: 8 · 2012: 9
- FWCI
- 0.46
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Sensors (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Dépôt institutionnel de l'Université libre de Bruxelles (Université Libre de Bruxelles) (submittedVersion, other-oa)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- Fonds De La Recherche Scientifique - FNRS
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › Motor Control and Adaptation
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Keywords
- movement disorders, wearable sensors, sensor fusion, brain-computer interface, signal processing, non-stationary signals, older adults
- MeSH terms
- Biofeedback, Psychology, Electrodes, Humans, Man-Machine Systems, Movement, Signal Processing, Computer-Assisted, Therapy, Computer-Assisted, Tremor, User-Computer Interface
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-10-10, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-10 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (gpt-6-sol).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.