The DOI matches its Crossref record; 108 of the 111 references it cites were found in a registry or an index.
Recent Advances in Neural Recording Microsystems
Open accessAbstract
The accelerating pace of research in neuroscience has created a considerable demand for neural interfacing microsystems capable of monitoring the activity of large groups of neurons. These emerging tools have revealed a tremendous potential for the advancement of knowledge in brain research and for the development of useful clinical applications. They can extract the relevant control signals directly from the brain enabling individuals with severe disabilities to communicate their intentions to other devices, like computers or various prostheses. Such microsystems are self-contained devices composed of a neural probe attached with an integrated circuit for extracting neural signals from multiple channels, and transferring the data outside the body. The greatest challenge facing development of such emerging devices into viable clinical systems involves addressing their small form factor and low-power consumption constraints, while providing superior resolution. In this paper, we survey the recent progress in the design and the implementation of multi-channel neural recording Microsystems, with particular emphasis on the design of recording and telemetry electronics. An overview of the numerous neural signal modalities is given and the existing microsystem topologies are covered. We present energy-efficient sensory circuits to retrieve weak signals from neural probes and we compare them. We cover data management and smart power scheduling approaches, and we review advances in low-power telemetry. Finally, we conclude by summarizing the remaining challenges and by highlighting the emerging trends in the field.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Figures






Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“In the dc-coupled topology shown in Fig. 6(b), the input offsets are removed via an active low-pass filter in the feedback path, forming a Miller integrator and avoiding the need for large input capacitors, which saves considerable area [159], [172].”
From Active Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review (2024) · cites this paper as [159]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hodgkin, A. L., & Huxley, A. F. (1952) · The Journal of Physiology · doi:10.1113/jphysiol.1952.sp004764 · Cited by 23,191
Receptive fields of single neurones in the cat's striate cortex
Hubel, D. H., & Wiesel, T. N. (1959) · The Journal of Physiology · doi:10.1113/jphysiol.1959.sp006308 · Cited by 4,653
Neuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295
Neuronal Population Coding of Movement Direction
Georgopoulos, A. P., Schwartz, A. B., & Kettner, R. E. (1986) · Science · doi:10.1126/science.3749885 · Cited by 3,219
MODALITY AND TOPOGRAPHIC PROPERTIES OF SINGLE NEURONS OF CAT'S SOMATIC SENSORY CORTEX
Mountcastle, V. B. (1957) · Journal of Neurophysiology · doi:10.1152/jn.1957.20.4.408 · Cited by 2,411
A low-power low-noise cmos for amplifier neural recording applications
Harrison, R. R., & Charles, C. (2003) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2003.811979 · Cited by 1,695
Direct Cortical Control of 3D Neuroprosthetic Devices
Taylor, D. M., Tillery, S. I. H., & Schwartz, A. B. (2002) · Science · doi:10.1126/science.1070291 · Cited by 1,542
Real-time prediction of hand trajectory by ensembles of cortical neurons in primates
Wessberg, J., Stambaugh, C. R., Kralik, J. D., Beck, P. D., Laubach, M., Chapin, J. K., Kim, J., Biggs, S. J., Srinivasan, M. A., & Nicolelis, M. A. L. (2000) · Nature · doi:10.1038/35042582 · Cited by 1,491
A review of methods for spike sorting: the detection and classification of neural action potentials
Lewicki, M. S. (1998) · Network Computation in Neural Systems · doi:10.1088/0954-898x_9_4_001 · Cited by 1,372
RamRakhyani, A. K., Mirabbasi, S., & Chiao, M. (2010) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2010.2072782 · Cited by 950
Jow, U.-M., & Ghovanloo, M. (2007) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2007.913130 · Cited by 628
Schwartz, A., Kettner, R. E., & Georgopoulos, A. P. (1988) · Journal of Neuroscience · doi:10.1523/jneurosci.08-08-02913.1988 · Cited by 565
Verma, N., Shoeb, A. H., Bohorquez, J. L., Dawson, J. L., Guttag, J. V., & Chandrakasan, A. P. (2010) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2010.2042245 · Cited by 528
An Energy-Efficient Micropower Neural Recording Amplifier
Wattanapanitch, W., Fee, M., & Sarpeshkar, R. (2007) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2007.907868 · Cited by 441
A 1-V 450-nW fully integrated programmable biomedical sensor interface chip.
Zou, X., Xu, X., Yao, L., & Lian, Y. (2009) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2009.2014707 · Cited by 414
The Science of Neural Interface Systems
Hatsopoulos, N. G., & Donoghue, J. P. (2009) · Annual Review of Neuroscience · doi:10.1146/annurev.neuro.051508.135241 · Cited by 388
A 128-Channel 6 mW Wireless Neural Recording IC With Spike Feature Extraction and UWB Transmitter
Chae, M. S., Yang, Z., Yuce, M. R., Hoang, L., & Liu, W. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2021607 · Cited by 369
Microelectrodes, Microelectronics, and Implantable Neural Microsystems
Wise, K. D., Sodagar, A. M., Yao, Y., Gulari, M. N., Perlin, G. E., & Najafi, K. (2008) · Proceedings of the IEEE · doi:10.1109/jproc.2008.922564 · Cited by 342
Advanced Neurotechnologies for Chronic Neural Interfaces: New Horizons and Clinical Opportunities
Kipke, D. R., Shain, W. G., Buzsáki, G., Fetz, E. E., Henderson, J. M., Hetke, J. F., & Schalk, G. (2008) · Journal of Neuroscience · doi:10.1523/jneurosci.3879-08.2008 · Cited by 294
An Integrated 256-Channel Epiretinal Prosthesis
Chen, K., Yang, Z., Hoang, L., Weiland, J. D., Humayun, M. S., & Liu, W. (2010) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2010.2055371 · Cited by 266
A 30 $\mu$W Analog Signal Processor ASIC for Portable Biopotential Signal Monitoring
Yazıcıoğlu, R. F., Kim, S. Y., Torfs, T., Kim, H. J., & Hoof, C. A. V. (2010) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2010.2085930 · Cited by 263
The 128-Channel Fully Differential Digital Integrated Neural Recording and Stimulation Interface
Shahrokhi, F., Abdelhalim, K., Serletis, D., Carlen, P. L., & Genov, R. (2010) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2010.2041350 · Cited by 263
Evaluation of Spike-Detection Algorithms for a Brain-Machine Interface Application
Iyad Obeid, A., & Wolf, P. D. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.826683 · Cited by 262
Modeling and optimization of printed spiral coils in air, saline, and muscle tissue environments
Jow, U.-M., & Ghovanloo, M. (2009) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2009.2025366 · Cited by 241
Wireless multichannel biopotential recording using an integrated FM telemetry circuit
Mohseni, P., Najafi, K., Eliades, S. J., & Wang, X. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.853625 · Cited by 220
Lee, S. B., Lee, H.-M., Kiani, M., Jow, U.-M., & Ghovanloo, M. (2010) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2010.2078814 · Cited by 220
Wireless Neural Recording With Single Low-Power Integrated Circuit
Harrison, R. R., Kier, R. J., Chestek, C. A., Gilja, V., Nuyujukian, P., Ryu, S. I., Greger, B. E., Solzbacher, F., & Shenoy, K. V. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2023298 · Cited by 208
Ghovanloo, M., & Atluri, S. (2007) · IEEE Transactions on Circuits and Systems I Fundamental Theory and Applications · doi:10.1109/tcsi.2007.905187 · Cited by 206
A Mixed-Signal Multichip Neural Recording Interface With Bandwidth Reduction
Gosselin, B. J., Ayoub, A. E., Roy, J.-F., Sawan, M., Leporé, F., Chaudhuri, A., & Guitton, D. (2009) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2009.2013718 · Cited by 204
Self-citationWireless smart implants dedicated to multichannel monitoring and microstimulation
Sawan, M., Hu, Y., & Coulombe, J. (2005) · IEEE Circuits and Systems Magazine · doi:10.1109/mcas.2005.1405898 · Cited by 201
Atluri, S., & Ghovanloo, M. (2006) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2006.1692789 · Cited by 195
NeuroMEMS: Neural Probe Microtechnologies
Hajj-Hassan, M., Chodavarapu, V. P., & Musallam, S. (2008) · Sensors · doi:10.3390/s8106704 · Cited by 194
High-Speed OQPSK and Efficient Power Transfer Through Inductive Link for Biomedical Implants
Simard, G., Sawan, M., & Massicotte, D. (2010) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2009.2039212 · Cited by 193
256-Channel Neural Recording and Delta Compression Microsystem With 3D Electrodes
Aziz, J. N. Y., Abdelhalim, K., Shulyzki, R., Genov, R., Bardakjian, B. L., Derchansky, M., Serletis, D., & Carlen, P. L. (2009) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2008.2010997 · Cited by 184
OlssonIII, R. H., Buhl, D. L., Sirota, A. M., Buzsaki, G., & Wise, K. D. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.847540 · Cited by 181
A Low-Power Integrated Bioamplifier With Active Low-Frequency Suppression
Gosselin, B. J., Sawan, M., & Chapman, C. A. (2007) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2007.914490 · Cited by 176
Self-citationA Fully Integrated Neural Recording Amplifier With DC Input Stabilization
Mohseni, P., & Najafi, K. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.824126 · Cited by 173
Micropower Circuits for Bidirectional Wireless Telemetry in Neural Recording Applications
Neihart, N., & Harrison, R. R. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.856247 · Cited by 172
Integrated circuit amplifiers for multi-electrode intracortical recording
Jochum, T., Denison, T., & Wolf, P. D. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/1/012001 · Cited by 169
Mollazadeh, M., Murari, K., Cauwenberghs, G., & Thakor, N. V. (2009) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2008.2005297 · Cited by 163
Power-Efficient Impedance-Modulation Wireless Data Links for Biomedical Implants
Mandal, S., & Sarpeshkar, R. (2008) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2008.2005295 · Cited by 163
Miranda, H. C., Gilja, V., Chestek, C. A., Shenoy, K. V., & Meng, T. H. Y. (2010) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2010.2044573 · Cited by 161
Low-Power Ultrawideband Wireless Telemetry Transceiver for Medical Sensor Applications
Gao, Y., Zheng, Y., Diao, S., Toh, W.-D., Ang, C.-W., Je, M., & Heng, C.-H. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2097262 · Cited by 152
A 5 $\mu$W/Channel Spectral Analysis IC for Chronic Bidirectional Brain–Machine Interfaces
Avestruz, A.-T., Santa, W. A., Carlson, D., Jensen, R. M., Stanslaski, S. R., Helfenstine, A., & Denison, T. (2008) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2008.2006460 · Cited by 142
Implantable biomedical microsystems for neural prostheses
Stieglitz, T., Schuetter, M., & Koch, K. P. (2005) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2005.1511501 · Cited by 139
A low-power integrated circuit for adaptive detection of action potentials in noisy signals
Harrison, R. R. (2004) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2003.1280856 · Cited by 138
A Fully Integrated Mixed-Signal Neural Processor for Implantable Multichannel Cortical Recording
Sodagar, A. M., Wise, K. D., & Najafi, K. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.894986 · Cited by 133
A Low-Noise Preamplifier with Adjustable Gain and Bandwidth for Biopotential Recording Applications
Yin, M., & Ghovanloo, M. (2007) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2007.378400 · Cited by 131
VLSI Potentiostat Array With Oversampling Gain Modulation for Wide-Range Neurotransmitter Sensing
Stanaćević, M., Murari, K., Rege, A., Cauwenberghs, G., & Thakor, N. V. (2007) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2007.893176 · Cited by 129
Nurmikko, A. V., Donoghue, J. P., Hochberg, L. R., Patterson, W. R., Song, Y., Bull, C. W., Borton, D. A., Laiwalla, F., Park, S., Yin, M., et al. (2010) · Proceedings of the IEEE · doi:10.1109/jproc.2009.2038949 · Cited by 128
The Development of Brain-Machine Interface Neuroprosthetic Devices
Patil, P. G., & Turner, D. A. (2008) · Neurotherapeutics · doi:10.1016/j.nurt.2007.11.002 · Cited by 119
Amperometric Electrochemical Microsystem for a Miniaturized Protein Biosensor Array
Yang, C., Huang, Y., Hassler, B. L., Worden, R. M., & Mason, A. J. (2009) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2009.2015650 · Cited by 119
Perelman, Y., & Ginosar, R. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.883732 · Cited by 116
A Sub-Microwatt Low-Noise Amplifier for Neural Recording
Holleman, J. H., & Otis, B. P. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4353193 · Cited by 111
Design of a CMOS Potentiostat Circuit for Electrochemical Detector Arrays
Ayers, S., Gillis, K. D., Lindau, M., & Minch, B. A. (2007) · IEEE Transactions on Circuits and Systems I Regular Papers · doi:10.1109/tcsi.2006.888777 · Cited by 109
Active Microelectronic Neurosensor Arrays for Implantable Brain Communication Interfaces
Song, Y., Borton, D. A., Park, S., Patterson, W. R., Bull, C. W., Laiwalla, F., Mislow, J. M. K., Simeral, J. D., Donoghue, J. P., & Nurmikko, A. V. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2024310 · Cited by 94
A low-power CMOS neural amplifier with amplitude measurements for spike sorting
Horiuchi, T. K., Swindell, T., Sander, D., & Abshier, P. (2004) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2004.1328932 · Cited by 92
An Ultra Low-Power CMOS Automatic Action Potential Detector
Gosselin, B. J., & Sawan, M. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2018103 · Cited by 92
Self-citationLow-Power Circuits for Brain–Machine Interfaces
Sarpeshkar, R., Wattanapanitch, W., Arfin, S. K., Rapoport, B. I., Mandal, S., Baker, M. W., Fee, M. S., Musallam, S., & Andersen, R. A. (2008) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2008.2003198 · Cited by 91
A Wireless Implantable Microsystem for Multichannel Neural Recording
Sodagar, A. M., Wise, K. D., & Najafi, K. (2009) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2009.2029957 · Cited by 90
Low-Power Impulse UWB Architectures and Circuits
Chandrakasan, A. P., Lee, F. S., Wentzloff, D. D., Sze, V., Ginsburg, B. P., Mercier, P. P., Daly, D. C., & Blázquez, R. (2009) · Proceedings of the IEEE · doi:10.1109/jproc.2008.2008787 · Cited by 85
Zhu, Y., Zuegel, J. D., Marciante, J. R., & Wu, H. (2009) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2009.2013770 · Cited by 77
Kamboh, A. M., Raetz, M., Oweiss, K. G., & Mason, A. J. (2007) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2007.907557 · Cited by 74
Rizk, M., Obeid, I., Callender, S. H., & Wolf, P. D. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/3/016 · Cited by 71
Validation of adaptive threshold spike detector for neural recording
Watkins, P., Santhanam, G., Shenoy, K. V., & Harrison, R. R. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2004.1404138 · Cited by 67
Very Low-Noise ENG Amplifier System Using CMOS Technology
Rieger, R., Schuettler, M., Pal, D., Clarke, C., Langlois, P., Taylor, J., & Donaldson, N. (2006) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2006.886731 · Cited by 57
In-vivo EEG recording using a wireless implantable neural transceiver
Irazoqui-Pastor, P., Módy, I., & Judy, J. W. (2004) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/cne.2003.1196905 · Cited by 55
A 500µW neural tag with 2µVrms AFE and frequency-multiplying MICS/ISM FSK transmitter
Rai, S., Holleman, J. H., Pandey, J., Zhang, F., & Otis, B. P. (2009) · Digest of technical papers/Digest of technical papers - IEEE International Solid-State Circuits Conference · doi:10.1109/isscc.2009.4977383 · Cited by 54
Mollazadeh, M., Murari, K., Cauwenberghs, G., & Thakor, N. V. (2009) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2009.2031877 · Cited by 53
Wideband Near-Field Data Transmission Using Pulse Harmonic Modulation
Inanlou, F., & Ghovanloo, M. (2010) · IEEE Transactions on Circuits and Systems I Regular Papers · doi:10.1109/tcsi.2010.2055351 · Cited by 51
Integrated potentiostat for neurotransmitter sensing
Murari, K., Stanaćević, M., Cauwenberghs, G., & Thakor, N. V. (2005) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2005.1549726 · Cited by 49
Linear-Phase Delay Filters for Ultra-Low-Power Signal Processing in Neural Recording Implants
Gosselin, B. J., Sawan, M., & Kerhervé, É. (2010) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2010.2045756 · Cited by 48
Self-citationAn Adaptive Sampling System for Sensor Nodes in Body Area Networks
Rieger, R., & Taylor, J. T. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.2008648 · Cited by 38
Towards a next generation neural interface: Optimizing power, bandwidth and data quality
Eftekhar, A., Sivylla, E. P., & Constandinou, T. G. (2010) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2010.5709586 · Cited by 38
A micro-power neural spike detector and feature extractor in .13μm CMOS
Holleman, J. H., Mishra, A., Diorio, C., & Otis, B. P. (2008) · Custom Integrated Circuits Conference · doi:10.1109/cicc.2008.4672089 · Cited by 34
Roham, M., Daberkow, D. P., Ramsson, E. S., Covey, D. P., Pakdeeronachit, S., Garris, P. A., & Mohseni, P. (2008) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2008.918282 · Cited by 32
Fully-differential self-biased bio-potential amplifier
Chae, M. S., Kim, J., & Liu, W. (2008) · Electronics Letters · doi:10.1049/el:20089097 · Cited by 31
Low-Power Circuits for Brain-Machine Interfaces
Sarpeshkar, R., Wattanapanitch, W., Rapoport, B. I., Arfin, S. K., Baker, M., Mandal, S., Fee, M. S., Musallam, S., & Andersen, R. A. (2007) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2007.378505 · Cited by 31
A 1V 22µW 32-channel implantable EEG recording IC
Zou, X., Liew, W.-S., Yao, L., & Lian, Y. (2010) · Digest of technical papers/Digest of technical papers - IEEE International Solid-State Circuits Conference · doi:10.1109/isscc.2010.5434024 · Cited by 30
A Tunable Biquad Switched-Capacitor Amplifier-Filter for Neural Recording
Lee, J., Johnson, M. D., & Kipke, D. R. (2010) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2010.2066272 · Cited by 30
Embedded Neural Recording With TinyOS-Based Wireless-Enabled Processor Modules
Farshchi, S., Pesterev, A. A., Nuyujukian, P., Guenterberg, E., Módy, I., & Judy, J. W. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2039606 · Cited by 30
Patch-clamp amplifiers on a chip
Weerakoon, P., Culurciello, E., Yang, Y., Santos‐Sacchi, J., Kindlmann, P. J., & Sigworth, F. J. (2010) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2010.06.030 · Cited by 28
Design strategies for multi-channel low-noise recording systems
Rieger, R., & Taylor, J. T. (2008) · Analog Integrated Circuits and Signal Processing · doi:10.1007/s10470-008-9230-5 · Cited by 28
Neural Probes for Concurrent Detection of Neurochemical and Electrophysiological Signals in vivo
Johnson, M. D., Franklin, R. K., Scott, K., Brown, R. B., & Kipke, D. R. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2005.1616203 · Cited by 27
Bonfanti, A. G., Ceravolo, M., Zambra, G., Gusmeroli, R., Spinelli, A. S., Lacaita, A. L., Angotzi, G. N., Baranauskas, G., & Fadiga, L. (2010) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2010.5626696 · Cited by 24
Djemouai, A., & Sawan, M. (1999) · Wiley Encyclopedia of Electrical and Electronics Engineering · doi:10.1002/047134608x.w6605 · Cited by 23
Song, Y., Stein, J., Patterson, W. R., Bull, C. W., Davitt, K. M., Serruya, M. D., Zhang, J., Nurmikko, A. V., & Donoghue, J. P. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/3/006 · Cited by 23
A neural amplifier with high programmable gain and tunable bandwidth
Perlin, G. E., Sodagar, A. M., & Wise, K. D. (2008) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2008.4649873 · Cited by 20
Adaptive detection of action potentials using ultra low-power CMOS circuits
Gosselin, B. J., & Sawan, M. (2008) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2008.4696911 · Cited by 20
Self-citationA low-power analog spike detector for extracellular neural recordings
Rogers, C. L., & Harris, J. G. (2005) · IEEE International Conference on Electronics, Circuits and Systems (ICECS) · doi:10.1109/icecs.2004.1399675 · Cited by 18
Towards Next Generation Neural Interfaces: Optimizing Power, Bandwidth and Data Quality
Eftekhar, A., Paraskevopoulou, S. E., & Constandinou, T. G. (2010) · Spiral (Imperial College London) · Cited by 16
Real-time variance based template matching spike sorting system
Haas, A. M., Cohen, M. H., & Abshire, P. (2007) · IEEE/NIH Life Science Systems and Applications Workshop · doi:10.1109/lssa.2007.4400895 · Cited by 16
Real-Time Decision Fusion for Multimodal Neural Prosthetic Devices
White, J. R., Levy, T. J., Bishop, W. E., & Beaty, J. D. (2010) · PLoS ONE · doi:10.1371/journal.pone.0009493 · Cited by 14
Integrated electrochemical neurosensors
Strong, T. D., Martin, S. M., Franklin, R. F., & Brown, R. B. (2006) · 2006 IEEE International Symposium on Circuits and Systems · doi:10.1109/iscas.2006.1693533 · Cited by 13
Toward Energy Efficient Neural Interfaces
Peng, C.-C., Xiao, Z., & Bashirullah, R. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2029704 · Cited by 13
A compact, nano-power CMOS action potential detector
Hiseni, S., Sawigun, C., Ngamkham, W., & Serdijn, W. A. (2009) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2009.5372074 · Cited by 13
Circuits techniques and microsystems assembly for intracortical multichannel ENG recording
Gosselin, B. J., & Sawan, M. (2009) · Custom Integrated Circuits Conference · doi:10.1109/cicc.2009.5280894 · Cited by 12
Self-citationAn adaptive neural spike detector with threshold-lock loop
Peng, C.-C., Sabharwal, P., & Bashirullah, R. (2009) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2009.5118217 · Cited by 11
Charvet, G., Billoint, O., Gharbi, S., Heuschkel, M. O., Georges, C., Kauffmann, T., Pellissier, A., Yvert, B., & Guillemaud, R. (2010) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2010.5626403 · Cited by 10
A high-performance analog front-end for an intraoral tongue-operated assistive technology
Gosselin, B. J., & Ghovanloo, M. (2011) · doi:10.1109/iscas.2011.5938140 · Cited by 10
Self-citationZamani, H. A., & Mohseni, P. (2010) · Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2010.5626697 · Cited by 9
Guest Editorial Special Section on Wireless Neural Interfaces
Judy, J. W., & Markovi, D. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2029261 · Cited by 6
Wireless switch for implantable medical devices based on passive RF receiver
Jiang, H., Zhang, L., Zhang, C., & Wang, Z. (2008) · Electronics Letters · doi:10.1049/el:20081228 · Cited by 5
High-speed fluorescence imaging system for freely moving animals
Park, J. H., Pieribone, V. A., Kim, D.-S., Verhagen, J. V., von Hehn, C., & Culurciello, E. (2009) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2009.5118291 · Cited by 5
Gosselin, B. J., Khayat, S. S. H., Quotb, A., & Sawan, M. (2011) · PolyPublie (École Polytechnique de Montréal) · Cited by 3
Self-citationExtracellular recording system based on amplitude modulation for CMOS microelectrode arrays
Joye, N., Schmid, A., & Leblebici, Y. (2010) · doi:10.1109/biocas.2010.5709581 · Cited by 2
Guest Editorial - Special Issue on Selected Papers From ISCAS 2009
Hafliger, P. D., & Constandinou, T. G. (2010) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2010.2050363 · Cited by 1
Guest Editorial—Special Issue on Selected Papers From BioCAS 2011
Constandinou, T. G., & Hafliger, P. D. (2012) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2012.2226072 · Cited by 1
Research works printed but not linked: 1
- Kandel, ER, Schwartz, JH, and Jessell, TM (2000). Principles of Neural Science, McGraw-Hill Medical.
Cited by
Sorted by citations
Revealing neuronal function through microelectrode array recordings
Obien, M. E. J., Deligkaris, K., Bullmann, T., Bakkum, D. J., & Frey, U. (2015) · Frontiers in Neuroscience · doi:10.3389/fnins.2014.00423 · Cited by 705
Implantable devices: issues and challenges
Bazaka, K., & Jacob, M. (2012) · Electronics · doi:10.3390/electronics2010001 · Cited by 358
Marx, U. (2016) · ALTEX · doi:10.14573/altex.1603161 · Cited by 295
Blind source identification from the multichannel surface electromyogram
Holobar, A., & Farina, D. (2014) · Physiological Measurement · doi:10.1088/0967-3334/35/7/r143 · Cited by 238
Dragas, J., Viswam, V., Shadmani, A., Chen, Y., Bounik, R., Stettler, A., Radivojević, M., Geissler, S. A., Obien, M. E. J., Müller, J., et al. (2017) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2017.2686580 · Cited by 207
Metadata
- Authors
- Gosselin, B.
- Affiliations
- Université Laval (CA)
- Corresponding author
- Gosselin, Benoit
- ORCID
- Gosselin, Benoit
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2011-04-27
- Volume
- 11
- Issue
- 5
- Pages
- 4572-4597
- ISSN
- 1424-8220 (ISSN-L)
- PMC
- PMC3231370
- OpenAlex
- W2153710474
- Cited by
- 138
- References
- 111
- Citations by year
- 2026: 4 · 2025: 2 · 2024: 7 · 2023: 7 · 2022: 10 · 2021: 9 · 2020: 8 · 2019: 5 · 2018: 9 · 2017: 12 · 2016: 12 · 2015: 21 · 2014: 19 · 2013: 5 · 2012: 7
- FWCI
- 0.82
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Sensors (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- CMC Microsystems
- Natural Sciences and Engineering Research Council of Canada
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
- Keywords
- neural interfaces, multichannel neural recording, neural probes, low-power circuits, data management, brain-computer interface, neural prostheses
- MeSH terms
- Equipment Design, Humans, Neurons, Telemetry, Biosensing Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review