The DOI matches its Crossref record; 160 of the 160 references it cites were found in a registry or an index.
Biodegradable metals
Abstract
After decades of developing strategies to minimize the corrosion of metallic biomaterials, there is now an increasing interest to use corrodible metals in a number of medical device applications. The term ‘‘biodegradable metal’’ (BM) has been used worldwide to describe these new kinds of degradable metallic biomaterials for medical applications and there were many new findings reported over the last decade. In this paper, the definition of BM and its classification are given for the first time, along with the summary of the degradation mechanisms of BMs and its environmental influencing factors, which includes the degeneration of mechanical integrity and the metabolism of the degradation products. The recentlydeveloped representative Mg-based BMs (pure Mg, Mg–Ca alloy, Mg–Zn alloy, etc.), Fe-based BMs (pure Fe, Fe–Mn-based alloys, etc.) and other BMs (pure W, pure Zn and its alloys, Ca-based and Sr-based bulk metallic glasses, etc.) were comprehensively reviewed with emphases on their microstructures, mechanical properties and degradation behaviors, in vitro and in vivo performances, pre-clinical and clinical trials. Moreover, current approaches to control their biodegradation rates to match the healing rates of the host tissues with various surface modification techniques and novel structural designs are summarized. Finally, this paper comprehensively discusses the directions of future development and the challenges of transitioning BMs from raw materials to semi-products to final medical devices. All in all, BM belongs to ‘‘bioactive’’ biomaterials and its future research and development direction should lean towards ‘‘third-generation biomedical materials’’ with ‘‘multifunctional capabilities’’ in a controllable manner to benefit the local tissue reconstruction. 2014 Elsevier B.V. All rights reserved.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Synthesis and surface engineering of iron oxide nanoparticles for biomedical applications
Gupta, A. K., & Gupta, M. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.10.012 · Cited by 6,771
(2013) · doi:10.1016/c2009-0-02433-7 · Cited by 5,127
Third-Generation Biomedical Materials
Hench, L. L., & Polak, J. M. (2002) · Science · doi:10.1126/science.1067404 · Cited by 2,789
Synthetic biodegradable polymers as orthopedic devices
Middleton, J. C., & Tipton, A. J. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00101-0 · Cited by 2,741
Journal of The American College of Cardiology
(2015) · Wilderness & Environmental Medicine · doi:10.1016/j.wem.2015.03.023 · Cited by 2,584
Hydrogen acts as a therapeutic antioxidant by selectively reducing cytotoxic oxygen radicals
Ohsawa, I., Ishikawa, M., Takahashi, K., Watanabe, M., Nishimaki, K., Yamagata, K., Katsura, K.-I., Katayama, Y., Asoh, S., & Ohta, S. (2007) · Nature Medicine · doi:10.1038/nm1577 · Cited by 2,560
In vivo corrosion of four magnesium alloys and the associated bone response
Witte, F., Kaese, V., Haferkamp, H., Switzer, E., Meyer-Lindenberg, A., Wirth, C. J., & Windhagen, H. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.09.049 · Cited by 2,395
Self-citationMahmoudi, M., Sant, S., Wang, B., Laurent, S., & Sen, T. (2011) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2010.05.006 · Cited by 1,881
The history of biodegradable magnesium implants: A review☆
Witte, F. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2010.02.028 · Cited by 1,860
Self-citationDegradable biomaterials based on magnesium corrosion
Witte, F., Hort, N., Vogt, C., Cohen, S., Kainer, K. U., Willumeit, R., & Feyerabend, F. (2008) · Current Opinion in Solid State and Materials Science · doi:10.1016/j.cossms.2009.04.001 · Cited by 1,820
Self-citationThe development of binary Mg–Ca alloys for use as biodegradable materials within bone
Li, Z., Gu, X., Lou, S., & Zheng, Y. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2007.12.021 · Cited by 1,593
Self-citationControl of biodegradation of biocompatable magnesium alloys
Song, G. (2007) · Corrosion Science · doi:10.1016/j.corsci.2007.01.001 · Cited by 1,514
In vitro and in vivo corrosion measurements of magnesium alloys
Witte, F., Fischer, J., Nellesen, J., Crostack, H.-A., Kaese, V., Pisch, A., Beckmann, F., & Windhagen, H. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.07.037 · Cited by 1,386
Self-citationIn vitro corrosion and biocompatibility of binary magnesium alloys
Gu, X., Zheng, Y., Cheng, Y., Zhong, S., & Xi, T. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2008.10.021 · Cited by 1,343
Self-citationResearch on an Mg–Zn alloy as a degradable biomaterial
Zhang, S., Zhang, X., Zhao, C., Li, J., Song, Y., Xie, C., Tao, H., Zhang, Y., He, Y., Jiang, Y., et al. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2009.06.028 · Cited by 1,336
A Physically Transient Form of Silicon Electronics
Hwang, S.-W., Tao, H., Kim, D.-H., Cheng, H., Song, J.-K., Rill, E., Brenckle, M. A., Panilaitis, B., Won, S. M., Kim, Y.-S., et al. (2012) · Science · doi:10.1126/science.1226325 · Cited by 1,286
Journal of Materials Science: Materials in Medicine
(2013) · Journal of Materials Science Materials in Medicine · doi:10.1007/10856.1573-4838 · Cited by 1,219
Nanoscale zero-valent iron: Future prospects for an emerging water treatment technology
Crane, R. A., & Scott, T. B. (2012) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2011.11.073 · Cited by 1,154
Journal of Achievements in Materials and Manufacturing Engineering
(2017) · Journal of Achievements of Materials and Manufacturing Engineering · doi:10.5604/17348412 · Cited by 978
Serruys, P. W., Luijten, H. E., Beatt, K. J., Geuskens, R., de Feyter, P. J., van den Brand, M., Reiber, J. H., ten Katen, H. J., van Es, G. A., & Hugenholtz, P. G. (1988) · Circulation · doi:10.1161/01.cir.77.2.361 · Cited by 931
Present Knowledge in Nutrition
(2012) · doi:10.1002/9781119946045 · Cited by 907
Erbel, R., Di Mario, C., Bartunek, J., Bonnier, J., de Bruyne, B., Eberli, F. R., Erne, P., Haude, M., Heublein, B., Horrigan, M., et al. (2007) · The Lancet · doi:10.1016/s0140-6736(07)60853-8 · Cited by 907
MgZnCa glasses without clinically observable hydrogen evolution for biodegradable implants
Zberg, B., Uggowitzer, P. J., & Löffler, J. F. (2009) · Nature Materials · doi:10.1038/nmat2542 · Cited by 899
Biocorrosion of magnesium alloys: a new principle in cardiovascular implant technology?
Heublein, B., Rohde, R., Kaese, V, Niemeyer, M., Hartung, W., & Haverich, A. (2003) · Heart · doi:10.1136/heart.89.6.651 · Cited by 806
In vitro studies of biomedical magnesium alloys in a simulated physiological environment: A review
Xin, Y., Hu, T., & Chu, P. K. (2011) · Acta Biomaterialia · doi:10.1016/j.actbio.2010.12.004 · Cited by 729
Vojtěch, D., Kubásek, J., Šerák, J., & Novák, P. (2011) · Acta Biomaterialia · doi:10.1016/j.actbio.2011.05.008 · Cited by 708
Processing of biocompatible porous Ti and Mg
Wen, C. E., Mabuchi, M., Yamada, Y., Shimojima, K., Chino, Y., & Asahina, T. (2001) · Scripta Materialia · doi:10.1016/s1359-6462(01)01132-0 · Cited by 665
Biodegradable magnesium–hydroxyapatite metal matrix composites
Witte, F., Feyerabend, F., Maier, P., Fischer, J., Störmer, M., Blawert, C., Dietzel, W., & Hort, N. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2006.12.027 · Cited by 642
Self-citationMagnesium alloys as implant materials – Principles of property design for Mg–RE alloys☆
Hort, N., Huang, Y., Fechner, D., Störmer, M., Blawert, C., Witte, F., Vogt, C., Drücker, H., Willumeit‐Römer, R., & Kainer, K. U. (2009) · Acta Biomaterialia · doi:10.1016/j.actbio.2009.09.010 · Cited by 608
Self-citationBiodegradable Metals for Cardiovascular Stent Application: Interests and New Opportunities
Moravej, M., & Mantovani, D. (2011) · International Journal of Molecular Sciences · doi:10.3390/ijms12074250 · Cited by 600
Feyerabend, F., Fischer, J., Holtz, J., Witte, F., Willumeit, R., Drücker, H., Vogt, C., & Hort, N. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2009.09.024 · Cited by 598
Self-citationWong, H. M., Yeung, K. W. K., Lam, K. O., Tam, V., Chu, P. K., Luk, K. D. K., & Cheung, K. M. C. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2009.11.111 · Cited by 579
Peuster, M., Wohlsein, P., Brügmann, M., Ehlerding, M., Seidler, K., Fink, C., Brauer, H., Fischer, A., & Hausdorf, G. (2001) · Heart · doi:10.1136/heart.86.5.563 · Cited by 569
Cytotoxicity evaluation of 43 metal salts using murine fibroblasts and osteoblastic cells
Yamamoto, A., Honma, R., & Sumita, M. (1998) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199802)39:2<331::aid-jbm22>3.0.co;2-e · Cited by 569
Long-term biocompatibility of a corrodible peripheral iron stent in the porcine descending aorta
Peuster, M., Hesse, C., Schloo, T., Fink, C., Beerbaum, P., & von Schnakenburg, C. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2006.05.029 · Cited by 558
Forrester, J. S., Fishbein, M., Helfant, R., & Fagin, J. (1991) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(10)80196-2 · Cited by 557
Kannan, M. B., & Raman, R. K. S. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.02.003 · Cited by 545
Windhagen, H., Radtke, K., Weizbauer, A., Diekmann, J., Noll, Y., Kreimeyer, U., Schavan, R., Stukenborg-Colsman, C., & Waizy, H. (2013) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-12-62 · Cited by 521
In vivo corrosion behavior of Mg‐Mn‐Zn alloy for bone implant application
Xu, L., Yu, G., Zhang, E., Pan, F., & Yang, K. (2007) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31273 · Cited by 520
Xu, L., Pan, F., Yu, G., Yang, L., Zhang, E., & Yang, K. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2008.12.001 · Cited by 505
Zhang, E., Yin, D., Xu, L., Yang, L., & Yang, K. (2009) · Materials Science and Engineering: C · doi:10.1016/j.msec.2008.08.024 · Cited by 480
Gu, X. N., Xie, X. H., Li, N., Zheng, Y. F., & Qin, L. (2012) · Acta Biomaterialia · doi:10.1016/j.actbio.2012.02.018 · Cited by 478
Self-citationLi, L., Gao, J., & Wang, Y. (2004) · Surface and Coatings Technology · doi:10.1016/j.surfcoat.2004.01.004 · Cited by 441
In vivo corrosion and corrosion protection of magnesium alloy LAE442☆
Witte, F., Fischer, J., Nellesen, J., Vogt, C., Vogt, J., Donath, T., & Beckmann, F. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2009.10.012 · Cited by 438
Self-citationCastellani, C., Lindtner, R. A., Hausbrandt, P., Tschegg, E., Stanzl-Tschegg, S. E., Zanoni, G., Beck, S., & Weinberg, A.-M. (2011) · Acta Biomaterialia · doi:10.1016/j.actbio.2010.08.020 · Cited by 436
Drug‐Eluting Bioabsorbable Magnesium Stent
DI MARIO, C., GRIFFITHS, H., GOKTEKIN, O., PEETERS, N., VERBIST, J., BOSIERS, M., DELOOSE, K., HEUBLEIN, B., ROHDE, R., KASESE, V., et al. (2004) · Journal of Interventional Cardiology · doi:10.1111/j.1540-8183.2004.04081.x · Cited by 428
Haude, M., Erbel, R., Erne, P., Verheye, S., Degen, H., Böse, D., Vermeersch, P., Wijnbergen, I., Weissman, N., Prati, F., et al. (2013) · The Lancet · doi:10.1016/s0140-6736(12)61765-6 · Cited by 423
Corrosion of, and cellular responses to Mg–Zn–Ca bulk metallic glasses
Gu, X., Zheng, Y., Zhong, S., Xi, T., Wang, J., & Wang, W. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2009.11.015 · Cited by 413
Self-citationBiodegradable magnesium scaffolds: Part 1: Appropriate inflammatory response
Witte, F., Ulrich, H., Rudert, M., & Willbold, E. (2007) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31170 · Cited by 409
Self-citationXin, Y., Huo, K., Tao, H., Tang, G., & Chu, P. K. (2008) · Acta Biomaterialia · doi:10.1016/j.actbio.2008.05.014 · Cited by 408
A method for the preparation of stable dispersion of zero-valent iron nanoparticles
Sun, Y.-P., Li, X.-Q., Zhang, W.-X., & Wang, H. P. (2007) · Colloids and Surfaces A: Physicochemical and Engineering Aspects · doi:10.1016/j.colsurfa.2007.05.029 · Cited by 407
Liu, B., & Zheng, Y. F. (2011) · Acta Biomaterialia · doi:10.1016/j.actbio.2010.11.001 · Cited by 396
Self-citationJournal-Cardiovascular Surgery
(2017) · Journal-Cardiovascular Surgery · doi:10.5455/jcvs · Cited by 386
Electrodeposition of Ca–P coatings on biodegradable Mg alloy: In vitro biomineralization behavior☆
Song, Y., Zhang, S., Li, J., Zhao, C., & Zhang, X. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2009.12.020 · Cited by 385
Corrosion resistance and surface biocompatibility of a microarc oxidation coating on a Mg–Ca alloy
Gu, X. N., Li, N., Zhou, W. R., Zheng, Y. F., Zhao, X., Cai, Q. Z., & Ruan, L. (2011) · Acta Biomaterialia · doi:10.1016/j.actbio.2010.11.034 · Cited by 383
Self-citationFe–Mn alloys for metallic biodegradable stents: Degradation and cell viability studies☆
Hermawan, H., Purnama, A., Dube, D., Couet, J., & Mantovani, D. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2009.11.025 · Cited by 372
Enhancement of Learning and Memory by Elevating Brain Magnesium
Slutsky, I., Abumaria, N., Wu, L.-J., Huang, C., Zhang, L., Li, B., Zhao, X., Govindarajan, A., Zhao, M.-G., Zhuo, M., et al. (2010) · Neuron · doi:10.1016/j.neuron.2009.12.026 · Cited by 371
Effect of inorganic salts, amino acids and proteins on the degradation of pure magnesium in vitro
Yamamoto, A., & Hiromoto, S. (2009) · Materials Science and Engineering: C · doi:10.1016/j.msec.2008.12.015 · Cited by 368
Wang, H. X., Guan, S. K., Wang, X., Ren, C. X., & Wang, L. G. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2009.12.009 · Cited by 359
Robinson, D. A., Griffith, R. W., Shechtman, D., Evans, R. B., & Conzemius, M. G. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2009.10.007 · Cited by 351
Corrosion fatigue behaviors of two biomedical Mg alloys – AZ91D and WE43 – In simulated body fluid
Gu, X. N., Zhou, W. R., Zheng, Y. F., Cheng, Y., Wei, S. C., Zhong, S. P., Xi, T. F., & Chen, L. J. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2010.07.026 · Cited by 350
Self-citationZartner, P., Cesnjevar, R., Singer, H., & Weyand, M. (2005) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.20520 · Cited by 347
Degradable metallic biomaterials: Design and development of Fe–Mn alloys for stents
Hermawan, H., Dube, D., & Mantovani, D. (2009) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.32224 · Cited by 332
Safety and efficacy of bioabsorbable magnesium alloy stents in porcine coronary arteries
Waksman, R., Pakala, R., Kuchulakanti, P. K., Baffour, R., Hellinga, D., Seabron, R., Tio, F. O., Wittchow, E., Hartwig, S., Harder, C., et al. (2006) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.20727 · Cited by 330
Janning, C., Willbold, E., Vogt, C., Nellesen, J., Meyer-Lindenberg, A., Windhagen, H., Thorey, F., & Witte, F. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2009.12.037 · Cited by 321
Self-citationBiodegradable magnesium scaffolds: Part II: Peri‐implant bone remodeling
Witte, F., Ulrich, H., Palm, C., & Willbold, E. (2007) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31293 · Cited by 312
Self-citationWen, C., Guan, S., Peng, L., Ren, C., Wang, X., & Hu, Z. (2009) · Applied Surface Science · doi:10.1016/j.apsusc.2008.09.078 · Cited by 312
Mg–Zr–Sr alloys as biodegradable implant materials
Li, Y., Wen, C., Mushahary, D., Sravanthi, R., Harishankar, N., Pande, G., & Hodgson, P. (2012) · Acta Biomaterialia · doi:10.1016/j.actbio.2012.04.028 · Cited by 309
Pu, Z., Song, G.-L., Yang, S., Outeiro, J. C., Dillon, O. W., Puleo, D. A., & Jawahir, I. S. (2012) · Corrosion Science · doi:10.1016/j.corsci.2011.12.018 · Cited by 303
Zhang, B., Hou, Y., Wang, X., Wang, Y., & Geng, L. (2011) · Materials Science and Engineering: C · doi:10.1016/j.msec.2011.07.015 · Cited by 303
Calcium orthophosphate-based biocomposites and hybrid biomaterials
Dorozhkin, S. V. (2009) · Journal of Materials Science · doi:10.1007/s10853-008-3124-x · Cited by 300
Iron–manganese: new class of metallic degradable biomaterials prepared by powder metallurgy
Hermawan, H., Alamdari, H., Mantovani, D., & Dubé, D. (2008) · Powder Metallurgy · doi:10.1179/174329008x284868 · Cited by 287
Bornapour, M., Muja, N., Shum-Tim, D., Cerruti, M., & Pekguleryuz, M. (2013) · Acta Biomaterialia · doi:10.1016/j.actbio.2012.07.045 · Cited by 287
Zhang, E., Yang, L. J., Xu, J., & Chen, H. (2009) · Acta Biomaterialia · doi:10.1016/j.actbio.2009.11.024 · Cited by 282
Preparation and characterization of a new biomedical magnesium–calcium alloy
Wan, Y., Xiong, G., Luo, H., He, F., Huang, Y., & Zhou, X. (2008) · Materials & Design · doi:10.1016/j.matdes.2008.04.017 · Cited by 280
Concentration‐ and composition‐dependent effects of metal ions on human MG‐63 osteoblasts
Hallab, N. J., Vermes, C., Messina, C., Roebuck, K. A., Glant, T. T., & Jacobs, J. J. (2002) · Journal of Biomedical Materials Research · doi:10.1002/jbm.10106 · Cited by 280
Peeters, P., Bosiers, M., Verbist, J., Deloose, K., & Heublein, B. (2005) · Journal of Endovascular Therapy · doi:10.1583/04-1349r.1 · Cited by 275
Novel processing of iron–manganese alloy-based biomaterials by inkjet 3-D printing
Chou, D.-T., Wells, D., Hong, D., Lee, B., Kuhn, H., & Kumta, P. N. (2013) · Acta Biomaterialia · doi:10.1016/j.actbio.2013.04.016 · Cited by 259
In vivo evaluation of biodegradable magnesium alloy bone implant in the first 6 months implantation
Zhang, E., Xu, L., Yu, G., Pan, F., & Yang, K. (2009) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.32132 · Cited by 256
Revolutionizing biodegradable metals
Yun, Y., Dong, Z., Lee, N., Liu, Y., Xue, D., Guo, X., Kuhlmann, J., Doepke, A., Halsall, H. B., Heineman, W., et al. (2009) · Materials Today · doi:10.1016/s1369-7021(09)70273-1 · Cited by 252
Comparative in vitro Study on Pure Metals (Fe, Mn, Mg, Zn and W) as Biodegradable Metals
Cheng, J., Liu, B., Wu, Y. H., & Zheng, Y. F. (2013) · Journal of Materials Science & Technology · doi:10.1016/j.jmst.2013.03.019 · Cited by 249
Self-citationShort‐Term Effects of Biocorrodible Iron Stents in Porcine Coronary Arteries
WAKSMAN, R., PAKALA, R., BAFFOUR, R., SEABRON, R., HELLINGA, D., & TIO, F. O. (2008) · Journal of Interventional Cardiology · doi:10.1111/j.1540-8183.2007.00319.x · Cited by 244
Pu, Z., Outeiro, J. C., Batista, A. C., Dillon, O. W., Puleo, D. A., & Jawahir, I. S. (2011) · International Journal of Machine Tools and Manufacture · doi:10.1016/j.ijmachtools.2011.12.006 · Cited by 235
A study on alkaline heat treated Mg–Ca alloy for the control of the biocorrosion rate
Gu, X. N., Zheng, W., Cheng, Y., & Zheng, Y. F. (2009) · Acta Biomaterialia · doi:10.1016/j.actbio.2009.01.048 · Cited by 226
Self-citationZhang, X., Yuan, G., Mao, L., Niu, J., Fu, P., & Ding, W. (2011) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2011.05.026 · Cited by 224
Characteristics and cytocompatibility of biodegradable polymer film on magnesium by spin coating
Xu, L., & Yamamoto, A. (2012) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/j.colsurfb.2011.12.009 · Cited by 217
Kirkland, N. T., Birbilis, N., Walker, J., Woodfield, T., Dias, G. J., & Staiger, M. P. (2010) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.31687 · Cited by 216
Growth and characterization of Mg(OH)2 film on magnesium alloy AZ31
Zhu, Y., Wu, G., Zhang, Y.-H., & Zhao, Q. (2011) · Applied Surface Science · doi:10.1016/j.apsusc.2011.02.017 · Cited by 210
A corrosion model for bioabsorbable metallic stents
Grogan, J. A., O’Brien, B. J., Leen, S. B., & McHugh, P. E. (2011) · Acta Biomaterialia · doi:10.1016/j.actbio.2011.05.032 · Cited by 200
Zhang, X., Yuan, G., Niu, J., Fu, P., & Ding, W. (2012) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2012.02.002 · Cited by 200
Qiao, Z., Shi, Z., Hort, N., Zainal Abidin, N. I., & Atrens, A. (2012) · Corrosion Science · doi:10.1016/j.corsci.2012.04.030 · Cited by 199
Fluoride treatment and in vitro corrosion behavior of an AZ31B magnesium alloy
Yan, T., Tan, L., Xiong, D., Liu, X., Zhang, B., & Yang, K. (2010) · Materials Science and Engineering: C · doi:10.1016/j.msec.2010.03.007 · Cited by 198
Influence of Ca on the corrosion properties of magnesium for biomaterials
Kim, W.-C., Kim, J.-G., Lee, J.-Y., & Seok, H.-K. (2008) · Materials Letters · doi:10.1016/j.matlet.2008.06.028 · Cited by 195
A simplified in vivo approach for evaluating the bioabsorbable behavior of candidate stent materials
Pierson, D., Edick, J., Tauscher, A., Pokorney, E., Bowen, P., Gelbaugh, J., Stinson, J., Getty, H., Lee, C. H., Drelich, J., et al. (2012) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.31922 · Cited by 195
Zhang, X., Yuan, G., Mao, L., Niu, J., & Ding, W. (2012) · Materials Letters · doi:10.1016/j.matlet.2011.08.079 · Cited by 188
Preparation, mechanical properties and in vitro biodegradation of porous magnesium scaffolds
Zhuang, H., Han, Y., & Feng, A. (2008) · Materials Science and Engineering: C · doi:10.1016/j.msec.2008.04.001 · Cited by 185
Moravej, M., Purnama, A., Fiset, M., Couet, J., & Mantovani, D. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2010.01.008 · Cited by 184
In vitro degradation and cell attachment of a PLGA coated biodegradable Mg–6Zn based alloy
Li, J. N., Cao, P., Zhang, X. N., Zhang, S. X., & He, Y. H. (2010) · Journal of Materials Science · doi:10.1007/s10853-010-4688-9 · Cited by 177
A new nano-cryosurgical modality for tumor treatment using biodegradable MgO nanoparticles
Di, D.-R., He, Z.-Z., Sun, Z.-Q., & Liu, J. (2012) · Nanomedicine: Nanotechnology, Biology and Medicine · doi:10.1016/j.nano.2012.02.010 · Cited by 175
Continuum damage model for bioresorbable magnesium alloy devices — Application to coronary stents
Gastaldi, D., Sassi, V., Petrini, L., Vedani, M., Trasatti, S., & Migliavacca, F. (2011) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2010.11.003 · Cited by 173
Du, H., Wei, Z., Liu, X., & Zhang, E. (2011) · Materials Chemistry and Physics · doi:10.1016/j.matchemphys.2010.10.015 · Cited by 171
Molecular Hydrogen as an Emerging Therapeutic Medical Gas for Neurodegenerative and Other Diseases
Ohno, K., Ito, M., Ichihara, M., & Ito, M. (2012) · Oxidative Medicine and Cellular Longevity · doi:10.1155/2012/353152 · Cited by 169
Wen, Z., Wu, C., Dai, C., & Yang, F. (2009) · Journal of Alloys and Compounds · doi:10.1016/j.jallcom.2009.08.147 · Cited by 168
Cytotoxicity and cellular uptake of iron nanowires
Song, M.-M., Song, W., Bi, H., Wang, J., Wu, W., Sun, J., & Yu, M. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2009.11.034 · Cited by 158
In vitro degradation and cytotoxicity of Mg/Ca composites produced by powder metallurgy
Zheng, Y. F., Gu, X. N., Xi, Y. L., & Chai, D. L. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2009.10.009 · Cited by 158
Self-citationControl of magnesium corrosion and biocompatibility with biomimetic coatings
Keim, S., Brunner, J. G., Fabry, B., & Virtanen, S. (2010) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.31742 · Cited by 156
Thomann, M., Krause, C., Angrisani, N., Bormann, D., Hassel, T., Windhagen, H. J., & Meyer‐Lindenberg, A. (2010) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.32639 · Cited by 153
Control of smooth muscle cell proliferation by ferrous iron
Mueller, P. P., May, T., Perz, A., Häuser, H., & Peuster, M. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2005.10.042 · Cited by 148
Rettig, R., & Virtanen, S. (2007) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31550 · Cited by 148
Lei, T., Tang, W. N., Cai, S.-H., Feng, F.-F., & Li, N.-F. (2011) · Corrosion Science · doi:10.1016/j.corsci.2011.09.027 · Cited by 145
On the cytocompatibility of biodegradable Fe-based alloys
Schinhammer, M., Gerber, I., Hänzi, A. C., & Uggowitzer, P. J. (2012) · Materials Science and Engineering C · doi:10.1016/j.msec.2012.11.002 · Cited by 140
Low-modulus Mg/PCL hybrid bone substitute for osteoporotic fracture fixation
Wong, H. M., Wu, S., Chu, P. K.-H., Cheng, S. H., Luk, K. D. K., Cheung, K., & Yeung, K. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2013.05.062 · Cited by 132
Meng, E., Guan, S.-X., Wang, H. X., Wang, L. G., Zhu, S., Hu, J., Ren, C. X., Gao, J., & Feng, Y. (2010) · Applied Surface Science · doi:10.1016/j.apsusc.2010.12.073 · Cited by 131
Wegener, B., Sievers, B., Utzschneider, S., et al. (2011) · Materials Science and Engineering B · doi:10.1016/j.mseb.2011.04.017 · Cited by 129
Adjustment of the ratio of Ca/P in the ceramic coating on Mg alloy by plasma electrolytic oxidation
Yao, Z., Li, L., & Jiang, Z. (2009) · Applied Surface Science · doi:10.1016/j.apsusc.2009.02.082 · Cited by 128
Geometry parameterization and multidisciplinary constrained optimization of coronary stents
Pant, S., Bressloff, N. W., & Limbert, G. (2011) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-011-0293-3 · Cited by 122
Wang, H., Guan, S., Wang, Y.-S., Liu, H., Wang, H., Wang, L., Ren, C., Zhu, S., & Chen, K. (2011) · Colloids and Surfaces B Biointerfaces · doi:10.1016/j.colsurfb.2011.06.040 · Cited by 120
Liu, C., Xin, Y., Tian, X., & Chu, P. K.-H. (2007) · Thin Solid Films · doi:10.1016/j.tsf.2007.05.048 · Cited by 115
Thomann, M., Krause, C., Bormann, D., von der Höh, N., Windhagen, H. J., & Meyer‐Lindenberg, A. (2009) · Materialwissenschaft und Werkstofftechnik · doi:10.1002/mawe.200800412 · Cited by 112
Controlling the biodegradation rate of magnesium using biomimetic apatite coating
Zhang, Y., Zhang, G., & Wei, M. (2008) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.31228 · Cited by 111
Lu, P., Cao, L., Liu, Y., Xu, X., & Wu, X. (2010) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.31744 · Cited by 110
Surface modification of an Mg-1Ca alloy to slow down its biocorrosion by chitosan
Gu, X., Zheng, Y., Lan, Q., Cheng, Y., Zhang, Z., Xi, T., & ZHANG, D. (2009) · Biomedical Materials · doi:10.1088/1748-6041/4/4/044109 · Cited by 109
Self-citationIn vitro degradation of AZ31 magnesium alloy coated with nano TiO2 film by sol–gel method
Hu, J., Zhang, C., Cui, B., Bai, K., Guan, S., Wang, L., & Zhu, S. (2011) · Applied Surface Science · doi:10.1016/j.apsusc.2011.03.148 · Cited by 107
Zhang, W., Li, M., Chen, Q., Hu, W., Zhang, W., & Wang, X. (2012) · Materials & Design (1980-2015) · doi:10.1016/j.matdes.2012.03.006 · Cited by 99
Electrochemical deposition of conducting polymer coatings on magnesium surfaces in ionic liquid
Luo, X., & Cui, X. T. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2010.09.006 · Cited by 98
Cheng, J., & Zheng, Y. (2013) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.32783 · Cited by 97
Self-citationBiocompatibility of rapidly solidified magnesium alloy RS66 as a temporary biodegradable metal
Willbold, E., Kalla, K., Bartsch, I., et al. (2013) · Acta Biomaterialia · doi:10.1016/j.actbio.2013.02.015 · Cited by 95
Zartner, P. A., Buettner, M. J., Singer, H., & Sigler, M. (2007) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.20828 · Cited by 95
Srinivasan, P. B., Liang, J. Y., Blawert, C., Störmer, M., & Dietzel, W. (2010) · Applied Surface Science · doi:10.1016/j.apsusc.2010.01.069 · Cited by 92
Synthesis and characterization of Mg‐Ca‐Sr alloys for biodegradable orthopedic implant applications
Berglund, I. S., Brar, H. S., Dolgova, N. V., Acharya, A. P., Keselowsky, B. G., Sarntinoranont, M., & Manuel, M. V. (2012) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.32721 · Cited by 92
von der Höh, N., Bormann, D., Lucas, A., Denkena, B., Hackenbroich, C., & Meyer‐Lindenberg, A. (2009) · Advanced Engineering Materials · doi:10.1002/adem.200800273 · Cited by 87
Velikokhatnyi, O. I., & Kumta, P. N. (2009) · Acta Biomaterialia · doi:10.1016/j.actbio.2009.08.016 · Cited by 86
Li, Y., Hodgson, P. D., & Wen, C. (2010) · Journal of Materials Science · doi:10.1007/s10853-010-4843-3 · Cited by 85
Lu, P., Fan, H., Liu, Y., Cao, L., Wu, X., & Xu, X. (2010) · Colloids and Surfaces B Biointerfaces · doi:10.1016/j.colsurfb.2010.10.038 · Cited by 83
Chen, S., Guan, S., Li, W., Wang, H., Chen, J., Wang, Y.-S., & Wang, H. (2011) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.31982 · Cited by 77
Seitz, J., Collier, K., Wulf, E., Bormann, D., & Bach, F. (2011) · Advanced Engineering Materials · doi:10.1002/adem.201080144 · Cited by 72
Wu, G., Xu, R., Feng, K., Wu, S., Wu, Z., Sun, G., Zheng, G., Li, G., & Chu, P. K.-H. (2012) · Applied Surface Science · doi:10.1016/j.apsusc.2012.04.112 · Cited by 71
Gu, X., Wang, X., Li, N., Li, L., Zheng, Y. F., & Miao, X. (2011) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.31879 · Cited by 70
Self-citationMueller, P. P., Arnold, S., Badar, M., Bormann, D., Bach, F., Drynda, A., Meyer‐Lindenberg, A., Häuser, H., & Peuster, M. (2012) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.34223 · Cited by 70
Effect of heat treatment on the microstructures and damping properties of biomedical Mg–Zr alloy
Tsai, M.-H., Chen, M.-S., Lin, L.-H., Lin, M., Wu, C.-Z., Ou, K., & Yu, C.-H. (2010) · Journal of Alloys and Compounds · doi:10.1016/j.jallcom.2010.09.098 · Cited by 65
Novel sol–gel derived calcium phosphate coatings on Mg4Y alloy
Roy, A., Singh, S. S., Datta, M. K., Lee, B., Ohodnicki, J., & Kumta, P. N. (2011) · Materials Science and Engineering B · doi:10.1016/j.mseb.2011.08.007 · Cited by 59
da Conceição, T. F., Scharnagl, N., Dietzel, W., et al. (2010) · Corrosion Science · doi:10.1016/j.corsci.2010.09.040 · Cited by 59
Controllable degradation of biomedical magnesium by chromium and oxygen dual ion implantation
Xu, R., Wu, G., Yang, X., Hu, T., Lu, Q., & Chu, P. K.-H. (2011) · Materials Letters · doi:10.1016/j.matlet.2011.04.043 · Cited by 57
Wu, G., Feng, K., Shanaghi, A., Zhao, Y., Xu, R., Yuan, G., & Chu, P. K.-H. (2012) · Surface and Coatings Technology · doi:10.1016/j.surfcoat.2012.01.001 · Cited by 54
MAGNESIUM SCREW AND NAIL TRANSFIXION IN FRACTURES
McBride, E. D. (1938) · Southern Medical Journal · doi:10.1097/00007611-193805000-00010 · Cited by 51
Biocompatibility of Fe–O films synthesized by plasma immersion ion implantation and deposition
Zhu, S., Huang, N., Xu, S. L., Zhang, Y., Liu, H., Lei, Y., Sun, H. L., & Yao, Y. (2008) · Surface and Coatings Technology · doi:10.1016/j.surfcoat.2008.11.033 · Cited by 50
Formation and electrochemical behavior of Al and O plasma-implanted biodegradable Mg-Y-RE alloy
Zhao, Y., Wu, G., Pan, H., Yeung, K., & Chu, P. K.-H. (2011) · Materials Chemistry and Physics · doi:10.1016/j.matchemphys.2011.11.028 · Cited by 46
Liu, X. L., Zhou, W., Wu, Y., Cheng, Y., & Zheng, Y. (2013) · Materials Science and Engineering C · doi:10.1016/j.msec.2013.06.004 · Cited by 41
Self-citationCorrosion resistance and blood compatibility of lanthanum ion implanted pure iron by MEVVA
Zhu, S., Huang, N., Shu, H., Wu, Y., & Xu, S. L. (2009) · Applied Surface Science · doi:10.1016/j.apsusc.2009.07.082 · Cited by 38
Gu, X., Li, X., Zhou, W., et al. (2010) · Biomedical Materials · doi:10.1088/1748-6041/5/3/035013 · Cited by 36
Self-citationFreeing the vessel from metallic cage: what can we achieve with bioresorbable vascular scaffolds?
Onuma, Y., Muramatsu, T., Kharlamov, A., & Serruys, P. W. J. C. (2012) · Cardiovascular Intervention and Therapeutics · doi:10.1007/s12928-012-0101-8 · Cited by 32
Magnesium seeds in the treatment of lymph- and haemangiomata
Wilflingseder, P., Martin, R., & Papp, C. (1981) · European Journal of Plastic Surgery · doi:10.1007/bf00289635 · Cited by 28
Wessels, V., Mené, G. L., Fischerauer, S., Kraus, T., Weinberg, A., Uggowitzer, P. J., & Löffler, J. F. (2012) · Advanced Engineering Materials · doi:10.1002/adem.201180200 · Cited by 28
von der Höh, N., von Rechenberg, B., Bormann, D., et al. (2009) · Materialwissenschaft und Werkstofftechnik · doi:10.1002/mawe.200800378 · Cited by 26
Maier, O. (1940) · Deutsche Zeitschrift für Chirurgie · doi:10.1007/bf02794837 · Cited by 24
Potential antiosteoporosis effect of biodegradable magnesium implanted in STZ‐induced diabetic rats
Yang, W., Zhang, Y., Yang, J., Tan, L., & Yang, K. (2011) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.33201 · Cited by 23
Ueber Verwendung von Magnesium zur Behandlung von Blutgefässerkrankungen
Payr, E. (1902) · Deutsche Zeitschrift für Chirurgie · doi:10.1007/bf02816557 · Cited by 21
Vandamme, T. (1996) · International Journal of Pharmaceutics · doi:10.1016/s0378-5173(96)04727-8 · Cited by 17
Experimentelle Studie über die Resorption parenteral zugeführten metallischen Magnesiums
Hoffheinz, S., & Dimitroff, N. (1928) · Deutsche Zeitschrift für Chirurgie · doi:10.1007/bf02827373 · Cited by 10
Klinische und experimentelle Untersuchungen über die Payrsche Magnesiumpfeilbehandlung von Angiomen
Glass, E. (1926) · Deutsche Zeitschrift für Chirurgie · doi:10.1007/bf02795178 · Cited by 6
Cited by
Wang, X., Xu, S., Zhou, S., Xu, W., Leary, M., Choong, P., Qian, M., Brandt, M., & Xie, Y. M. (2016) · Biomaterials · doi:10.1016/j.biomaterials.2016.01.012 · Cited by 2,121
Fundamentals and advances in magnesium alloy corrosion
Esmaily, M., Svensson, J. E., Fajardo, S., Birbilis, N., Frankel, G. S., Virtanen, S., Arrabal, R., Thomas, S., & Johansson, L. G. (2017) · Progress in Materials Science · doi:10.1016/j.pmatsci.2017.04.011 · Cited by 2,073
The rise of plastic bioelectronics
Someya, T., Bao, Z., & Malliaras, G. G. (2016) · Nature · doi:10.1038/nature21004 · Cited by 1,884
Recent advances on the development of magnesium alloys for biodegradable implants
Chen, Y., Xu, Z., Smith, C., & Sankar, J. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2014.07.005 · Cited by 1,236
Corrosion of Metallic Biomaterials: A Review
Eliaz, N. (2019) · Materials · doi:10.3390/ma12030407 · Cited by 984
Metadata
- Authors
- Zheng, Y. F., Gu, X. N., & Witte, F.
- Venue
- Materials Science and Engineering: R: Reports
- Publisher
- Elsevier BV
- Published
- 2014-03
- Volume
- 77
- Pages
- 1-34
- ISSN
- 0927-796X (ISSN-L)
- OpenAlex
- W4211147970
- Cited by
- 2,436
- References
- 160
- FWCI
- 49.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.