Development of neural interfaces and energy harvesters towards self-powered implantable systems for healthcare monitoring and rehabilitation purposes
The DOI matches its Crossref record; 52 of the 52 references it cites were found in a registry or an index.
Abstract
Despite its great promise, neural interface has yet to substantially impact modern healthcare monitoring and therapeutic interventions. However, considering the recent development of self-power solutions, data transmission technologies, and artificial intelligence, neural interface has the potential to transform future clinical applications. Together with the recent self-powered energy harvesting technologies, neural interfaces are evolving towards fully implantable systems. Here, we first review the progress and current status of neural interfaces, start from the well-established neuromodulation protocols and efforts to translational applications, then move on to milestones of neural interface development, and end with the review on considerations and requirements of active and inactive materials. With the knowledge of neural interface current status, we further review implantable systems which are built on top of the neural interfaces. Particularly, we review well-established powering solutions. Furthermore, we summarize the recent demonstrations of direct tissue stimulation with self-powered energy harvesters in chronological order. In the end, we discuss the future opportunities and challenges in the direction towards self-powered systems for healthcare monitoring and rehabilitation purposes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Artificial intelligence in healthcare
Yu, K.-H., Beam, A. L., & Kohane, I. S. (2018) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0305-z · Cited by 2,817
Neural Stimulation and Recording Electrodes
Cogan, S. F. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160518 · Cited by 2,243 · cited 1×
“In addition to the consideration of electrode-tissue interaction, all neural interfaces have to fulfill general requirements to become approved as a medical device: they must not harm the body and should stay stable and functional over a certain life-time which is in most cases in the range of decades [79].”
BackgroundFully integrated silicon probes for high-density recording of neural activity
Jun, J. J., Steinmetz, N. A., Siegle, J. H., Denman, D. J., Bauza, M., Barbarits, B., Lee, A. K., Anastassiou, C. A., Andrei, A., Aydın, Ç., et al. (2017) · Nature · doi:10.1038/nature24636 · Cited by 2,190 · cited 4×
“Ranging from the commercialization of high-density brain probes, including the Neuropixels and Utah Electrode Array (UEA), to the exploratory stretchable peripheral nerve electrodes, neural interfaces have evolved for both CNS and PNS applications.”
BackgroundInfluentialResponse of brain tissue to chronically implanted neural electrodes
Polikov, V. S., Tresco, P. A., & Reichert, W. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.08.015 · Cited by 1,896
Dissolvable films of silk fibroin for ultrathin conformal bio-integrated electronics
Kim, D.-H., Viventi, J., Amsden, J. J., Xiao, J., Vigeland, L., Kim, Y.-S., Blanco, J. A., Panilaitis, B., Frechette, E. S., Contreras, D., et al. (2010) · Nature Materials · doi:10.1038/nmat2745 · Cited by 1,721 · cited 1×
“Natural polymer materials are also used as inactive substrates, such as silk, which dissolves to enhance adhesion to the biological tissue surface [69].”
BackgroundTargeted neurotechnology restores walking in humans with spinal cord injury
Wagner, F. B., Mignardot, J.-B., Le Goff-Mignardot, C. G., Demesmaeker, R., Komi, S., Capogrosso, M., Rowald, A., Seáñez, I., Caban, M., Pirondini, E., et al. (2018) · Nature · doi:10.1038/s41586-018-0649-2 · Cited by 1,087
Electronic dura mater for long-term multimodal neural interfaces
Minev, I. R., Musienko, P., Hirsch, A., Barraud, Q., Wenger, N., Moraud, E. M., Gandar, J., Capogrosso, M., Milekovic, T., Asboth, L., et al. (2015) · Science · doi:10.1126/science.1260318 · Cited by 1,082 · cited 1×
“electrode [41], bladder implant [42], and muscle electrode [43].”
Conformal piezoelectric energy harvesting and storage from motions of the heart, lung, and diaphragm
Dagdeviren, C., Yang, B. D., Su, Y., Tran, P. L., Joe, P., Anderson, E., Xia, J., Doraiswamy, V., Dehdashti, B., Feng, X., et al. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1317233111 · Cited by 975
Speech synthesis from neural decoding of spoken sentences
Anumanchipalli, G. K., Chartier, J., & Chang, E. F. (2019) · Nature · doi:10.1038/s41586-019-1119-1 · Cited by 883 · cited 1×
“Electrical recording from the brain has long been employed to decode motor intentions to achieve movement control [25,26], and more recently, it is proven that brain recording can be used to decipher complicated human speech [27].”
BackgroundCampbell, P. K., Jones, K. E., Huber, R. J., Horch, K. W., & Normann, R. A. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.83588 · Cited by 881
Transcutaneous ultrasound energy harvesting using capacitive triboelectric technology
Hinchet, R., Yoon, H.-J., Ryu, H., Kim, M.-K., Choi, E.-K., Kim, D.-S., & Kim, S.-W. (2019) · Science · doi:10.1126/science.aan3997 · Cited by 854
Soft and elastic hydrogel-based microelectronics for localized low-voltage neuromodulation
Liu, Y., Liu, J., Chen, S., Lei, T., Kim, Y., Niu, S., Wang, H., Wang, X., Foudeh, A. M., Tok, J. B.-H., et al. (2019) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0335-6 · Cited by 811
Soft, stretchable, fully implantable miniaturized optoelectronic systems for wireless optogenetics
Park, S. I., Brenner, D. S., Shin, G., Morgan, C. D., Copits, B. A., Chung, H. U., Pullen, M. Y., Noh, K. N., Davidson, S., Oh, S. J., et al. (2015) · Nature Biotechnology · doi:10.1038/nbt.3415 · Cited by 794
Direct effects of transcranial electric stimulation on brain circuits in rats and humans
Vöröslakos, M., Takeuchi, Y., Brinyiczki, K., Zombori, T., Oliva, A., Fernández-Ruiz, A., Kozák, G., Kincses, Z. T., Iványi, B., Buzsáki, G., et al. (2018) · Nature Communications · doi:10.1038/s41467-018-02928-3 · Cited by 735
A high-performance brain–computer interface
Santhanam, G., Ryu, S. I., Yu, B. M., Afshar, A., & Shenoy, K. V. (2006) · Nature · doi:10.1038/nature04968 · Cited by 698 · cited 1×
“Electrical recording from the brain has long been employed to decode motor intentions to achieve movement control [25,26], and more recently, it is proven that brain recording can be used to decipher complicated human speech [27].”
BackgroundSyringe-injectable electronics
Liu, J., Fu, T.-M., Cheng, Z., Hong, G., Zhou, T., Jin, L., Duvvuri, M., Jiang, Z., Kruskal, P., Xie, C., et al. (2015) · Nature Nanotechnology · doi:10.1038/nnano.2015.115 · Cited by 687
Canales, A., Jia, X., Froriep, U. P., Koppes, R. A., Tringides, C. M., Selvidge, J., Lu, C., Hou, C., Wei, L., Fink, Y., et al. (2015) · Nature Biotechnology · doi:10.1038/nbt.3093 · Cited by 668
Neural recording and modulation technologies
Chen, R., Canales, A., & Anikeeva, P. (2017) · Nature Reviews Materials · doi:10.1038/natrevmats.2016.93 · Cited by 655 · cited 1×
“conditions, for example, epilepsy, Alzheimer disease, depressive disorder, and multiple sclerosis, respectively, cause a huge social and economic burden on a global scale [8,9].”
BackgroundA Review of Organic and Inorganic Biomaterials for Neural Interfaces
Fattahi, P., Yang, G., Kim, G., & Abidian, M. R. (2014) · Advanced Materials · doi:10.1002/adma.201304496 · Cited by 580
Pandarinath, C., Nuyujukian, P., Blabe, C. H., Sorice, B. L., Saab, J., Willett, F. R., Hochberg, L. R., Shenoy, K. V., & Henderson, J. M. (2017) · eLife · doi:10.7554/elife.18554 · Cited by 566 · cited 1×
“Electrical recording from the brain has long been employed to decode motor intentions to achieve movement control [25,26], and more recently, it is proven that brain recording can be used to decipher complicated human speech [27].”
BackgroundWirelessly powered, fully internal optogenetics for brain, spinal and peripheral circuits in mice
Montgomery, K. L., Yeh, A. J., Ho, J. S., Tsao, V., Mohan Iyer, S., Grosenick, L., Ferenczi, E. A., Tanabe, Y., Deisseroth, K., Delp, S. L., et al. (2015) · Nature Methods · doi:10.1038/nmeth.3536 · Cited by 565
Park, D.-W., Schendel, A. A., Mikael, S., Brodnick, S. K., Richner, T. J., Ness, J. P., Hayat, M. R., Atry, F., Frye, S. T., Pashaie, R., et al. (2014) · Nature Communications · doi:10.1038/ncomms6258 · Cited by 565 · cited 1×
“To allow simultaneous optogenetics observations together with electrical stimulation, graphene is developed as an optically transparent active layer [68].”
BackgroundWireless Recording in the Peripheral Nervous System with Ultrasonic Neural Dust
Seo, D., Neely, R. M., Shen, K., Singhal, U., Alon, E., Rabaey, J. M., Carmena, J. M., & Maharbiz, M. M. (2016) · Neuron · doi:10.1016/j.neuron.2016.06.034 · Cited by 557 · cited 2×
“In addition to EM power transfer, the recently reported ultrasonic energy transfer opens another possibility of wireless energy supply [92].”
BackgroundYu, K. J., Kuzum, D., Hwang, S.-W., Kim, B. H., Juul, H., Kim, N. H., Won, S. M., Chiang, K., Trumpis, M., Richardson, A. G., et al. (2016) · Nature Materials · doi:10.1038/nmat4624 · Cited by 523
Next-generation probes, particles, and proteins for neural interfacing
Rivnay, J., Wang, H., Fenno, L., Deisseroth, K., & Malliaras, G. G. (2017) · Science Advances · doi:10.1126/sciadv.1601649 · Cited by 514
Wearable and Implantable Triboelectric Nanogenerators
Liu, Z., Li, H., Shi, B., Fan, Y., Wang, Z. L., & Li, Z. (2019) · Advanced Functional Materials · doi:10.1002/adfm.201808820 · Cited by 514
Koo, J., MacEwan, M. R., Kang, S.-K., Won, S. M., Stephen, M., Gamble, P., Xie, Z., Yan, Y., Chen, Y.-Y., Shin, J., et al. (2018) · Nature Medicine · doi:10.1038/s41591-018-0196-2 · Cited by 496 · cited 1×
“magnesium and silicon oxide opens a possibility to future transient electronics [71].”
BackgroundA transverse intrafascicular multichannel electrode (TIME) to interface with the peripheral nerve
Boretius, T., Badia, J., Pascual-Font, A., Schuettler, M., Navarro, X., Yoshida, K., & Stieglitz, T. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.05.010 · Cited by 468 · cited 2×
“(TIME) [56], longitudinal intrafascicular electrode (LIFE) [57], slanted Utah electrode array (SUEA) [58], and highly selective 3D spiked ultraflexible neural (SUN) interface [59].”
BackgroundThree-dimensional macroporous nanoelectronic networks as minimally invasive brain probes
Xie, C., Liu, J., Fu, T.-M., Dai, X., Zhou, W., & Lieber, C. M. (2015) · Nature Materials · doi:10.1038/nmat4427 · Cited by 404 · cited 3×
“Conventional silicon is engineered into ultrathin silicon layers to explore dissolvability of the silicon-based neural interface [84].”
BackgroundFunctionally selective peripheral nerve stimulation with a flat interface nerve electrode
Tyler, D. J., & Durand, D. M. (2002) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2002.806840 · Cited by 398 · cited 2×
“examples include flat-interface nerve electrode (FINE) [54], self-adaptive neural ribbon [38], pelvic nerve clip electrode [42], twining elec-”
BackgroundEffective Wound Healing Enabled by Discrete Alternative Electric Fields from Wearable Nanogenerators
Long, Y., Wei, H., Li, J., Yao, G., Yu, B., Ni, D., Gibson, A. L., Lan, X., Jiang, Y., Cai, W., et al. (2018) · ACS Nano · doi:10.1021/acsnano.8b07038 · Cited by 397 · cited 1×
“wound healing [127] by generating an electric field.”
BackgroundFormento, E., Minassian, K., Wagner, F., Mignardot, J. B., Le Goff-Mignardot, C. G., Rowald, A., Bloch, J., Micera, S., Capogrosso, M., & Courtine, G. (2018) · Nature Neuroscience · doi:10.1038/s41593-018-0262-6 · Cited by 370
Ma, Y., Zheng, Q., Liu, Y., Shi, B., Xue, X., Ji, W., Liu, Z., Jin, Y., Zou, Y., An, Z., et al. (2016) · Nano Letters · doi:10.1021/acs.nanolett.6b01968 · Cited by 367
Zhang, Y., Zheng, N., Cao, Y., Wang, F., Wang, P., Ma, Y., Lu, B., Hou, G., Fang, Z., Liang, Z., et al. (2019) · Science Advances · doi:10.1126/sciadv.aaw1066 · Cited by 314 · cited 1×
“trodes using shape memory material [55].”
Long-term stimulation and recording with a penetrating microelectrode array in cat sciatic nerve
Branner, A., Stein, R. B., Fernandez, E., Aoyagi, Y., & Normann, R. A. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.820321 · Cited by 301 · cited 2×
“(TIME) [56], longitudinal intrafascicular electrode (LIFE) [57], slanted Utah electrode array (SUEA) [58], and highly selective 3D spiked ultraflexible neural (SUN) interface [59].”
BackgroundChina Brain Project: Basic Neuroscience, Brain Diseases, and Brain-Inspired Computing
Poo, M.-M., Du, J.-L., Ip, N. Y., Xiong, Z.-Q., Xu, B., & Tan, T. (2016) · Neuron · doi:10.1016/j.neuron.2016.10.050 · Cited by 271
BION ™ system for distributed neural prosthetic interfaces
Loeb, G. E., Peck, R. A., Moore, W. H., & Hood, K. (2001) · Medical Engineering & Physics · doi:10.1016/s1350-4533(01)00011-x · Cited by 243
A multielectrode array for intrafascicular recording and stimulation in sciatic nerve of cats
Branner, A., & Normann, R. A. (2000) · Brain Research Bulletin · doi:10.1016/s0361-9230(99)00231-2 · Cited by 234
Lewis, P. M., Ackland, H. M., Lowery, A. J., & Rosenfeld, J. V. (2015) · Brain Research · doi:10.1016/j.brainres.2014.11.020 · Cited by 228
Orderly recruitment of motor units under optical control in vivo
Llewellyn, M. E., Thompson, K. R., Deisseroth, K., & Delp, S. L. (2010) · Nature Medicine · doi:10.1038/nm.2228 · Cited by 217
Zhang, Y., Mickle, A. D., Gutruf, P., McIlvried, L. A., Guo, H., Wu, Y., Golden, J. P., Xue, Y., Grajales-Reyes, J. G., Wang, X., et al. (2019) · Science Advances · doi:10.1126/sciadv.aaw5296 · Cited by 195
Design and validation of a foldable and photovoltaic wide-field epiretinal prosthesis
Ferlauto, L., Airaghi Leccardi, M. J. I., Chenais, N. A. L., Gilliéron, S. C. A., Vagni, P., Bevilacqua, M., Wolfensberger, T. J., Sivula, K., & Ghezzi, D. (2018) · Nature Communications · doi:10.1038/s41467-018-03386-7 · Cited by 183 · cited 1×
“tissues, examples include retinal prosthesis [35], cochlear implant [36], cardiac pacemaker [37], peripheral nerve electrode [38], brain electrode [39,40], spinal cord”
BackgroundShi, Q., & Lee, C. (2019) · Advanced Science · doi:10.1002/advs.201900617 · Cited by 174
Self-citationBeyond the brain: Optogenetic control in the spinal cord and peripheral nervous system
Montgomery, K. L., Iyer, S. M., Christensen, A. J., Deisseroth, K., & Delp, S. L. (2016) · Science Translational Medicine · doi:10.1126/scitranslmed.aad7577 · Cited by 147 · cited 1×
“merely the cortex to various biological tissues, including the spinal cord, the peripheral nerves [14,15], skeletal muscle tissues [16–18],”
BackgroundDeep Brain Stimulation: A Paradigm Shifting Approach to Treat Parkinson's Disease
Hickey, P., & Stacy, M. (2016) · Frontiers in Neuroscience · doi:10.3389/fnins.2016.00173 · Cited by 125 · cited 1×
“proval deep brain stimulation therapy for the treatment of Parkinson's disease [20], epilepsy [21], and dystonia [22].”
BackgroundXiang, Z., Yen, S., Sheshadri, S., Wang, J., Lee, S., Liu, Y., Liao, L., Thakor, N. V., & Lee, C. (2016) · Advanced Materials · doi:10.1002/adma.201503423 · Cited by 116
Self-citationA slowly penetrating interfascicular nerve electrode for selective activation of peripheral nerves
Tyler, D. J., & Durand, D. M. (1997) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.559349 · Cited by 108
Xiang, Z., Liu, J., & Lee, C. (2016) · Microsystems & Nanoengineering · doi:10.1038/micronano.2016.12 · Cited by 100
Self-citationToward Bioelectronic Medicine—Neuromodulation of Small Peripheral Nerves Using Flexible Neural Clip
Lee, S., Peh, W. Y. X., Wang, J., Yang, F., Ho, J. S., Thakor, N. V., Yen, S., & Lee, C. (2017) · Advanced Science · doi:10.1002/advs.201700149 · Cited by 96 · cited 2×
“examples include flat-interface nerve electrode (FINE) [54], self-adaptive neural ribbon [38], pelvic nerve clip electrode [42], twining elec-”
BackgroundSelf-citationImplanted stimulators for restoration of function in spinal cord injury
Bhadra, N., Kilgore, K. L., & Peckham, P. H. (2001) · Medical Engineering & Physics · doi:10.1016/s1350-4533(01)00012-1 · Cited by 92
Wang, J., Thow, X. Y., Wang, H., Lee, S., Voges, K., Thakor, N. V., Yen, S., & Lee, C. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201700987 · Cited by 43 · cited 1×
“(TIME) [56], longitudinal intrafascicular electrode (LIFE) [57], slanted Utah electrode array (SUEA) [58], and highly selective 3D spiked ultraflexible neural (SUN) interface [59].”
BackgroundSelf-citationMuceli, S., Bergmeister, K. D., Hoffmann, K.-P., Aman, M., Vukajlija, I., Aszmann, O. C., & Farina, D. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/aaed85 · Cited by 30
Cited by
Self‐Powered Respiration Monitoring Enabled By a Triboelectric Nanogenerator
Su, Y., Chen, G., Chen, C., Gong, Q., Xie, G., Yao, M., Tai, H., Jiang, Y., & Chen, J. (2021) · Advanced Materials · doi:10.1002/adma.202101262 · Cited by 481
Wen, F., Sun, Z., He, T., Shi, Q., Zhu, M., Zhang, Z., Li, L., Zhang, T., & Lee, C. (2020) · Advanced Science · doi:10.1002/advs.202000261 · Cited by 478
Self-citationZhang, Z., Wen, F., Sun, Z., Guo, X., He, T., & Lee, C. (2022) · Advanced Intelligent Systems · doi:10.1002/aisy.202100228 · Cited by 464
Self-citationDeep learning-enabled triboelectric smart socks for IoT-based gait analysis and VR applications
Zhang, Z., He, T., Zhu, M., Sun, Z., Shi, Q., Zhu, J., Dong, B., Yuce, M. R., & Lee, C. (2020) · npj Flexible Electronics · doi:10.1038/s41528-020-00092-7 · Cited by 413
Self-citationLiu, H., Fu, H., Sun, L., Lee, C., & Yeatman, E. M. (2021) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2020.110473 · Cited by 405
Self-citation
Metadata
- Authors
- Wang, J., He, T., & Lee, C.
- Venue
- Nano Energy
- Publisher
- Elsevier BV
- Published
- 2019-11
- Volume
- 65
- Pages
- 104039
- ISSN
- 2211-2855 (ISSN-L)
- OpenAlex
- W2967435171
- Cited by
- 129
- References
- 52
- FWCI
- 8.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.