The five percent electrode system for high-resolution EEG and ERP measurements
The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The ten-twenty electrode system of the international federation
Jasper, H. H. (1958) · Electroencephalography and Clinical Neurophysiology · Cited by 6,567
Talairach, J., Tournoux, P., & Rayport, M. (1988) · Thieme eBooks · Cited by 5,058
Picton, T. W., Bentin, S., Berg, P., Donchin, E., Hillyard, S. A., Johnson, R., Miller, G. A., Ritter, W., Ruchkin, D. S., Rugg, M. D., et al. (2000) · Psychophysiology · doi:10.1111/1469-8986.3720127 · Cited by 2,157
Imaging unconscious semantic priming
Dehaene, S., Naccache, L., Le Clec'H, G., Koechlin, E., Mueller, M., Dehaene-Lambertz, G., van de Moortele, P.-F., & Le Bihan, D. (1998) · Nature · doi:10.1038/26967 · Cited by 1,081
Ten Percent Electrode System for Topographic Studies of Spontaneous and Evoked EEG Activities
Chatrian, G. E., Lettich, E., & Nelson, P. L. (1985) · American Journal of EEG Technology · doi:10.1080/00029238.1985.11080163 · Cited by 681
IFCN standards for digital recording of clinical EEG
Nuwer, M. R., Comi, G., Emerson, R., Fuglsang-Frederiksen, A., Guérit, J.-M., Hinrichs, H., Ikeda, A., Jose C. Luccas, F., & Rappelsburger, P. (1998) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(97)00106-5 · Cited by 671
Guideline Thirteen: Guidelines for Standard Electrode Position Nomenclature
&NA; (1994) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199401000-00014 · Cited by 556
Craniocerebral topography within the international 10–20 system
Steinmetz, H., Fürst, G., & Meyer, B.-U. (1989) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(89)90227-7 · Cited by 256
Topography of the N400: brain electrical activity reflecting semantic expectancy
Curran, T., Tucker, D. M., Kutas, M., & Posner, M. I. (1993) · Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section · doi:10.1016/0168-5597(93)90004-9 · Cited by 237
Auditory Evoked Magnetic Fields and Electric Potentials
(1990) · Advances in Audiology · doi:10.1159/isbn.978-3-8055-5001-7 · Cited by 227
Cited by
Jurcak, V., Tsuzuki, D., & Dan, I. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2006.09.024 · Cited by 1,489
A technical guide to tDCS, and related non-invasive brain stimulation tools
Woods, A. J., Antal, A., Bikson, M., Boggio, P. S., Brunoni, A. R., Celnik, P., Cohen, L. G., Fregni, F., Herrmann, C. S., Kappenman, E. S., et al. (2016) · Clinical Neurophysiology · doi:10.1016/j.clinph.2015.11.012 · Cited by 1,439
Topographic ERP Analyses: A Step-by-Step Tutorial Review
Murray, M. M., Brunet, D., & Michel, C. M. (2008) · Brain Topography · doi:10.1007/s10548-008-0054-5 · Cited by 1,127
FASTER: Fully Automated Statistical Thresholding for EEG artifact Rejection
Nolan, H., Whelan, R., & Reilly, R. B. (2010) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2010.07.015 · Cited by 1,077
Keil, A., Debener, S., Gratton, G., Junghöfer, M., Kappenman, E. S., Luck, S. J., Luu, P., Miller, G. A., & Yee, C. M. (2014) · Psychophysiology · doi:10.1111/psyp.12147 · Cited by 699
Kayser, J., & Tenke, C. E. (2006) · Clinical Neurophysiology · doi:10.1016/j.clinph.2005.08.034 · Cited by 634
Virtual spatial registration of stand-alone fNIRS data to MNI space
Tsuzuki, D., Jurcak, V., Singh, A. K., Okamoto, M., Watanabe, E., & Dan, I. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2006.10.043 · Cited by 630
Koessler, L., Maillard, L., Benhadid, A., Vignal, J. P., Felblinger, J., Vespignani, H., & Braun, M. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.02.006 · Cited by 584
The standardized EEG electrode array of the IFCN
Seeck, M., Koessler, L., Bast, T., Leijten, F., Michel, C., Baumgartner, C., He, B., & Beniczky, S. (2017) · Clinical Neurophysiology · doi:10.1016/j.clinph.2017.06.254 · Cited by 489
MEG: An Introduction to Methods
(2010) · Oxford University Press eBooks · doi:10.1093/acprof:oso/9780195307238.001.0001 · Cited by 408
Emotion Assessment From Physiological Signals for Adaptation of Game Difficulty
Chanel, G., Rebetez, C., Bétrancourt, M., & Pun, T. (2011) · IEEE Transactions on Systems, Man, and Cybernetics - Part A: Systems and Humans · doi:10.1109/tsmca.2011.2116000 · Cited by 398
Musso, F., Brinkmeyer, J., Mobascher, A., Warbrick, T., & Winterer, G. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.01.093 · Cited by 387
“The standard electrode positions on the MNI152 scalp were taken from Jurcak et al. (2007) and Oostenveld and Praamstra (2001).”
MethodSleep Stage Classification Using EEG Signal Analysis: A Comprehensive Survey and New Investigation
Aboalayon, K., Faezipour, M., Almuhammadi, W., & Moslehpour, S. (2016) · Entropy · doi:10.3390/e18090272 · Cited by 382
Babayan, A., Erbey, M., Kumral, D., Reinelt, J. D., Reiter, A. M. F., Röbbig, J., Schaare, H. L., Uhlig, M., Anwander, A., Bazin, P.-L., et al. (2019) · Scientific Data · doi:10.1038/sdata.2018.308 · Cited by 364
Gola, M., Magnuski, M., Szumska, I., & Wróbel, A. (2013) · International Journal of Psychophysiology · doi:10.1016/j.ijpsycho.2013.05.007 · Cited by 362
EEG source localization: Sensor density and head surface coverage
Song, J., Davey, C., Poulsen, C., Luu, P., Turovets, S., Anderson, E., Li, K., & Tucker, D. (2015) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2015.08.015 · Cited by 356
Oddo, C. M., Raspopovic, S., Artoni, F., Mazzoni, A., Spigler, G., Petrini, F., Giambattistelli, F., Vecchio, F., Miraglia, F., Zollo, L., et al. (2016) · eLife · doi:10.7554/elife.09148 · Cited by 332
Clinical utility of EEG in diagnosing and monitoring epilepsy in adults
Tatum, W. O., Rubboli, G., Kaplan, P. W., Mirsatari, S. M., Radhakrishnan, K., Gloss, D., Caboclo, L. O., Drislane, F. W., Koutroumanidis, M., Schomer, D. L., et al. (2018) · Clinical Neurophysiology · doi:10.1016/j.clinph.2018.01.019 · Cited by 314
Li, Y., Zheng, W., Wang, L., Zong, Y., & Cui, Z. (2022) · IEEE Transactions on Affective Computing · doi:10.1109/taffc.2019.2922912 · Cited by 313
Very high density EEG elucidates spatiotemporal aspects of early visual processing
Robinson, A. K., Venkatesh, P., Boring, M. J., Tarr, M. J., Grover, P., & Behrmann, M. (2017) · Scientific Reports · doi:10.1038/s41598-017-16377-3 · Cited by 302
Wagner, J., Solis-Escalante, T., Grieshofer, P., Neuper, C., Müller-Putz, G., & Scherer, R. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.08.019 · Cited by 301
Kayser, J., & Tenke, C. E. (2006) · Clinical Neurophysiology · doi:10.1016/j.clinph.2005.08.033 · Cited by 290
Trends in EEG-BCI for daily-life: Requirements for artifact removal
Minguillon, J., Lopez-Gordo, M. A., & Pelayo, F. (2017) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2016.09.005 · Cited by 289
Maurer, U., Brandeis, D., & McCandliss, B. D. (2005) · Behavioral and Brain Functions · doi:10.1186/1744-9081-1-13 · Cited by 284
Functional brain network efficiency predicts intelligence
Langer, N., Pedroni, A., Gianotti, L. R. R., Hänggi, J., Knoch, D., & Jäncke, L. (2012) · Human Brain Mapping · doi:10.1002/hbm.21297 · Cited by 282
Kayser, J., & Tenke, C. E. (2003) · Clinical Neurophysiology · doi:10.1016/s1388-2457(03)00241-4 · Cited by 282
Acharya, J. N., Hani, A., Cheek, J., Thirumala, P., & Tsuchida, T. N. (2016) · Journal of Clinical Neurophysiology · doi:10.1097/wnp.0000000000000316 · Cited by 278
Grandy, T. H., Werkle‐Bergner, M., Chicherio, C., Schmiedek, F., Lövdén, M., & Lindenberger, U. (2013) · Psychophysiology · doi:10.1111/psyp.12043 · Cited by 276
Tsuzuki, D., & Dan, I. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.07.025 · Cited by 265
Huang, Y., Parra, L. C., & Haufe, S. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2015.12.019 · Cited by 259
EEG default mode network in the human brain: Spectral regional field powers
Chen, A. C. N., Feng, W., Zhao, H., Yin, Y., & Wang, P. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2007.12.064 · Cited by 257
Walking through Architectural Spaces: The Impact of Interior Forms on Human Brain Dynamics
Banaei, M., Hatami, J., Yazdanfar, A., & Gramann, K. (2017) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2017.00477 · Cited by 244
“Electrodes were placed in an elastic cap (EASYCAP, Herrsching, Germany) using a custom layout with equidistant distribution of electrodes approximating the 5% system (Oostenveld and Praamstra, 2001).”
MethodSubcortical sources dominate the neuroelectric auditory frequency-following response to speech
Bidelman, G. M. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2018.03.060 · Cited by 241
“Neuroelectric activity was recorded from 64 sintered Ag/AgCl electrodes at standard 10-10 scalp locations (Oostenveld and Praamstra, 2001).”
Kayser, J., & Tenke, C. E. (2015) · International Journal of Psychophysiology · doi:10.1016/j.ijpsycho.2015.04.012 · Cited by 234
“Scalp potentials were simulated for a fully-balanced, 81-channel 10–10 system EEG montage (Oostenveld and Praamstra, 2001) using a four-shell forward solution (Berg, 2006) with radial dipoles located 14 mm below the outer scalp surface (85 mm head radius), expanding in ‘cap size’ from a focal…”
InfluentialElectroencephalography (EEG) Technology Applications and Available Devices
Soufineyestani, M., Dowling, D., & Khan, A. (2020) · Applied Sciences · doi:10.3390/app10217453 · Cited by 230
“Electrode positions and labels in the 10 ± 20 system [8].”
BackgroundInfluentialeConnectome: A MATLAB toolbox for mapping and imaging of brain functional connectivity
He, B., Dai, Y., Astolfi, L., Babiloni, F., Yuan, H., & Yang, L. (2011) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2010.11.015 · Cited by 229
“Connectivity patterns at the EEG sensor level can also be visualized overlaying on a spherical head model, where the standard 10-5 electrode system (Oostenveld and Praamstra, 2001) is used.”
MethodIndividual alpha peak frequency is related to latent factors of general cognitive abilities
Grandy, T. H., Werkle-Bergner, M., Chicherio, C., Lövdén, M., Schmiedek, F., & Lindenberger, U. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.04.059 · Cited by 228
Recognition of human emotions using EEG signals: A review
Rahman, M. M., Sarkar, A. K., Hossain, M. A., Hossain, M. S., Islam, M. R., Hossain, M. B., Quinn, J. M. W., & Moni, M. A. (2021) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2021.104696 · Cited by 227
Balconi, M., Grippa, E., & Vanutelli, M. E. (2015) · Brain and Cognition · doi:10.1016/j.bandc.2015.02.001 · Cited by 227
Electroencephalography and High-Density Electrophysiological Source Localization
Pizzagalli, D. A. (2009) · Handbook of Psychophysiology · doi:10.1017/cbo9780511546396.003 · Cited by 226
“In recent years, this system has been extended to the so-called 10–10 system (American Electroencephalographic Society, 1991) and the 5–5 system (Oostenveld & Praamstra, 2001), in which intermediate positions between those of the 10–20 system have been derived (Figure 3.3).”
MethodInfluentialPrecise Slow Oscillation–Spindle Coupling Promotes Memory Consolidation in Younger and Older Adults
Muehlroth, B. E., Sander, M. C., Fandakova, Y., Grandy, T. H., Rasch, B., Shing, Y. L., & Werkle-Bergner, M. (2019) · Scientific Reports · doi:10.1038/s41598-018-36557-z · Cited by 226
EEG beta suppression and low gamma modulation are different elements of human upright walking
Seeber, M., Scherer, R., Wagner, J., Solis-Escalante, T., & Müller-Putz, G. R. (2014) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2014.00485 · Cited by 219
“The electrode montage was in accordance with the 5% international 10/20 EEG system (EasyCap, Germany; Oostenveld and Praamstra, 2001).”
Simultaneous acquisition of EEG and NIRS during cognitive tasks for an open access dataset
Shin, J., von Lühmann, A., Kim, D.-W., Mehnert, J., Hwang, H.-J., & Müller, K.-R. (2018) · Scientific Data · doi:10.1038/sdata.2018.3 · Cited by 218
D’Anna, E., Petrini, F. M., Artoni, F., Popovic, I., Simanić, I., Raspopovic, S., & Micera, S. (2017) · Scientific Reports · doi:10.1038/s41598-017-11306-w · Cited by 215
Neurophysiology of Implicit Timing in Serial Choice Reaction-Time Performance
Praamstra, P., Kourtis, D., Fei Kwok, H., & Oostenveld, R. (2006) · The Journal of Neuroscience · doi:10.1523/jneurosci.0440-06.2006 · Cited by 214
“The electrodes were placed according to the 10 –5 electrode system (Oostenveld and Praamstra, 2001) using a nylon electrode cap.”
MethodSelf-citationEEG Source Connectivity Analysis: From Dense Array Recordings to Brain Networks
Hassan, M., Dufor, O., Merlet, I., Berrou, C., & Wendling, F. (2014) · PLoS ONE · doi:10.1371/journal.pone.0105041 · Cited by 208
GMSS: Graph-Based Multi-Task Self-Supervised Learning for EEG Emotion Recognition
Li, Y., Chen, J., Li, F., Fu, B., Wu, H., Ji, Y., Zhou, Y., Niu, Y., Shi, G., & Zheng, W. (2023) · IEEE Transactions on Affective Computing · doi:10.1109/taffc.2022.3170428 · Cited by 207
“Due to the different effects of brain regions on emotion expression, the spatial jigsaw puzzle task is defined as a series of brain region permutations [56], [57], [58], [59].”
BackgroundMethodPourtois, G., Sander, D., Andres, M., Grandjean, D., Reveret, L., Olivier, E., & Vuilleumier, P. (2004) · European Journal of Neuroscience · doi:10.1111/j.1460-9568.2004.03794.x · Cited by 205
“Using the 5% electrode system (Oostenveld & Praamstra, 2001), the right somatosensory and right superior lateral temporal cortices were located and marked over the EEG cap on the right side (C4 and CP6, respectively) of the head (for a similar approach to localize primary somatosensory cortex, see…”
Multimodal data as a means to understand the learning experience
Giannakos, M. N., Sharma, K., Pappas, I. O., Kostakos, V., & Velloso, E. (2019) · International Journal of Information Management · doi:10.1016/j.ijinfomgt.2019.02.003 · Cited by 202
On the Potential of a New Generation of Magnetometers for MEG: A Beamformer Simulation Study
Boto, E., Bowtell, R., Krüger, P., Fromhold, T. M., Morris, P. G., Meyer, S. S., Barnes, G. R., & Brookes, M. J. (2016) · PLOS ONE · doi:10.1371/journal.pone.0157655 · Cited by 194
Simultaneous recording of EEG and facial muscle reactions during spontaneous emotional mimicry
Achaibou, A., Pourtois, G., Schwartz, S., & Vuilleumier, P. (2008) · Neuropsychologia · doi:10.1016/j.neuropsychologia.2007.10.019 · Cited by 194
Hou, X., Liu, Y., Sourina, O., Tan, Y. R. E., Wang, L., & Mueller-Wittig, W. (2015) · 2015 IEEE International Conference on Systems, Man, and Cybernetics · doi:10.1109/smc.2015.540 · Cited by 186
Seeber, M., Scherer, R., Wagner, J., Solis-Escalante, T., & Müller-Putz, G. R. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.03.045 · Cited by 186
“Multichannel EEG (120 channels) was recorded by combining four 32-channel amplifiers (BrainAmp, Brainproducts, Germany).”
MethodInfluentialJobert, M., Wilson, F. J., Ruigt, G. S. F., Brunovsky, M., Prichep, L. S., Drinkenburg, W. H. I. M., & The IPEG Pharmaco-EEG Guideline Committee (2012) · Neuropsychobiology · doi:10.1159/000343478 · Cited by 185
“If additional EEG electrodes are used (e.g. for mapping or localisation studies), then the international extended 10–20 electrode placement sys-tem (also known as 10% system [39–41] ) should be utilised.”
BackgroundArtoni, F., Fanciullacci, C., Bertolucci, F., Panarese, A., Makeig, S., Micera, S., & Chisari, C. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2017.07.013 · Cited by 183
“With the pre-computed high-resolution lead field matrix (2054 × 7850) relating all the scalp surface voxels to the source voxels, a specific lead field matrix for a user-defined electrode montage (standard 10–20 System in this case) can be constructed as a subset of the precomputed lead field matrix and then used to s…”
MethodMu rhythm desynchronization reveals motoric influences of hand action on object recognition
Kumar, S., Riddoch, M. J., & Humphreys, G. (2013) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2013.00066 · Cited by 183
“The electrodes were placed according to the 10-5 electrode system (Oostenveld and Praamstra, 2001) using a nylon electrode cap.”
Method128-Channel EEG Source Imaging in Epilepsy: Clinical Yield and Localization Precision
Michel, C. M., Lantz, G., Spinelli, L., de Peralta, R. G., Landis, T., & Seeck, M. (2004) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-200403000-00001 · Cited by 183
“It has not been until recently that EEG systems with the same high number of sensors and very fast scalp application have become available (Oostenveld and Praamstra, 2001; Suarez et al., 2000; Tucker, 1993).”
BackgroundThe effects of working memory training on functional brain network efficiency
Langer, N., von Bastian, C. C., Wirz, H., Oberauer, K., & Jäncke, L. (2013) · Cortex · doi:10.1016/j.cortex.2013.01.008 · Cited by 176
“The standard electrode positions on the MNI152 scalp were taken from Jurcak et al. (2007) and Oostenveld and Praamstra (2001).”
BackgroundMethodBCI Demographics II: How Many (and What Kinds of) People Can Use a High-Frequency SSVEP BCI?
Volosyak, I., Valbuena, D., Luth, T., Malechka, T., & Graser, A. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2121919 · Cited by 175
“They were placed on for ground and as the input electrodes on the international system of EEG measurement [ 37 ].”
MethodDecoding Brain Representations by Multimodal Learning of Neural Activity and Visual Features
Palazzo, S., Spampinato, C., Kavasidis, I., Giordano, D., Schmidt, J., & Shah, M. (2021) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2020.2995909 · Cited by 175
Gramann, K., Onton, J., Riccobon, D., Mueller, H. J., Bardins, S., & Makeig, S. (2010) · Journal of Cognitive Neuroscience · doi:10.1162/jocn.2009.21369 · Cited by 172
Yao, D., Wang, L., Oostenveld, R., Nielsen, K. D., Arendt-Nielsen, L., & Chen, A. C. N. (2005) · Physiological Measurement · doi:10.1088/0967-3334/26/3/003 · Cited by 172
“Electrodes were applied to the scalp using a carefully positioned nylon cap in accordance with the 10–5 extension of the International 10–20 electrode system (Oostenveld and Praamstra 2001).”
MethodSelf-citationVanneste, S., van de Heyning, P., & De Ridder, D. (2011) · European Journal of Neuroscience · doi:10.1111/j.1460-9568.2011.07793.x · Cited by 171
“The standard electrode positions on theMNI152 scalp were taken from (Jurcak et al., 2007) and (Oostenveld & Praamstra, 2001).”
BackgroundOfner, P., Schwarz, A., Pereira, J., Wyss, D., Wildburger, R., & Müller-Putz, G. R. (2019) · Scientific Reports · doi:10.1038/s41598-019-43594-9 · Cited by 166
It's how you get there: walking down a virtual alley activates premotor and parietal areas
Wagner, J., Solis-Escalante, T., Scherer, R., Neuper, C., & Müller-Putz, G. (2014) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2014.00093 · Cited by 163
“Electrodes were mounted in an electrode cap (EasyCap, Germany) according to the 5% 10/20 system (Oostenveld and Praamstra, 2001).”
MethodHuang, D., Chen, S., Liu, C., Zheng, L., Tian, Z., & Jiang, D. (2021) · Neurocomputing · doi:10.1016/j.neucom.2021.03.105 · Cited by 163
Bidelman, G. M. (2015) · Hearing Research · doi:10.1016/j.heares.2015.01.011 · Cited by 161
“Multichannel speech-evoked FFRs were recorded from 64 sintered Ag/AgCl electrodes at standard 10e20 locations around the scalp (Oostenveld and Praamstra, 2001).”
MethodCerebral peak alpha frequency predicts individual differences in pain sensitivity
Furman, A. J., Meeker, T. J., Rietschel, J. C., Yoo, S., Muthulingam, J., Prokhorenko, M., Keaser, M. L., Goodman, R. N., Mazaheri, A., & Seminowicz, D. A. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2017.11.042 · Cited by 161
“95 EEG 96 Scalp EEG was collected from an EEG cap housing a 64 channel Brain Vision actiCAP system (Brain Products GmbH, 97 Munich, Germany) labeled in accord with an extended international 10–20 system (Oostenveld and Praamstra, 2001).”
InfluentialWagner, J., Wessel, J. R., Ghahremani, A., & Aron, A. R. (2018) · Journal of Cognitive Neuroscience · doi:10.1162/jocn_a_01183 · Cited by 112
Bashivan, P., Bidelman, G. M., & Yeasin, M. (2014) · European Journal of Neuroscience · doi:10.1111/ejn.12749 · Cited by 91
“%)”
MethodRapid extraction of auditory feature contingencies
Bendixen, A., Prinz, W., Horváth, J., Trujillo-Barreto, N. J., & Schröger, E. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2008.03.040 · Cited by 88
“htm), which roughly corresponds to the 10–5 extension of the international 10–20 system (Oostenveld and Praamstra, 2001).”
BackgroundMethodTang, M. F., Smout, C. A., Arabzadeh, E., & Mattingley, J. B. (2018) · eLife · doi:10.7554/elife.33123 · Cited by 83
“The 64 active scalp Ag/AgCl electrodes were arranged according to the international standard 10–20 system for electrode placement (Oostenveld & Praamstra, 2001) using a nylon head cap.”
Whitford, T. J., Kubicki, M., Ghorashi, S., Schneiderman, J. S., Hawley, K. J., McCarley, R. W., Shenton, M. E., & Spencer, K. M. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.10.048 · Cited by 83
“Image modified from Oostenveld and Praamstra (2001).”
Stylianou, M., Murphy, N., Peraza, L. R., Graziadio, S., Cromarty, R., Killen, A., O' Brien, J. T., Thomas, A. J., LeBeau, F. E. N., & Taylor, J.-P. (2018) · Clinical Neurophysiology · doi:10.1016/j.clinph.2018.03.013 · Cited by 79
Douglas, Z. H., Maniscalco, B., Hallett, M., Wassermann, E. M., & He, B. J. (2015) · The Journal of Neuroscience · doi:10.1523/jneurosci.4894-14.2015 · Cited by 51
“Electrode nomenclature follows the 128-channel high-density EEG based on the extended International 10 –20 system (Oostenveld and Praamstra, 2001).”
MethodElectrophysiological evidence for a general auditory prediction deficit in adults who stutter
Daliri, A., & Max, L. (2015) · Brain and Language · doi:10.1016/j.bandl.2015.08.008 · Cited by 50
“EEG signals were recorded from 128 standard sites on the scalp according to an extension of the international 10-20 electrode system (Gilmore, 1994; Oostenveld & Praamstra, 2001).”
Wong, W., Noreika, V., Móró, L., Revonsuo, A., Windt, J., Valli, K., & Tsuchiya, N. (2020) · Neuroscience of Consciousness · doi:10.1093/nc/niaa006 · Cited by 40
Vase, L., Egsgaard, L. L., Nikolajsen, L., Svensson, P., Jensen, T. S., & Arendt-Nielsen, L. (2012) · Experimental Brain Research · doi:10.1007/s00221-012-3027-6 · Cited by 35
Rezaee, Z., Kaura, S., Solanki, D., Dash, A., Srivastava, M. V. P., Lahiri, U., & Dutta, A. (2020) · Brain Sciences · doi:10.3390/brainsci10020094 · Cited by 31
“A subject-specific cap fitted to the individual head model was created using the high-density 10-05 EEG locations [43], EGI net-based system (https://www.”
MethodDzafic, I., Larsen, K. M., Darke, H., Pertile, H., Carter, O., Sundram, S., & Garrido, M. I. (2021) · Schizophrenia Bulletin · doi:10.1093/schbul/sbaa188 · Cited by 24
Cortical Tracking of Continuous Speech Under Bimodal Divided Attention
Xie, Z., Brodbeck, C., & Chandrasekaran, B. (2023) · Neurobiology of Language · doi:10.1162/nol_a_00100 · Cited by 21
Olson, R. L., Cleveland, D. J., & Materia, M. (2023) · Behavioral Sciences · doi:10.3390/bs13050401 · Cited by 11
“P3 Event-Related Potential (ERP) Continuous EEG was recorded from 28 monopolar electrode sites (FP1, FP2, F3, F4, F7, F8, FC1, FC2, FC5, FC6, C3, C4, CP1, CP2, CP5, CP6, TP9, TP10, P3, P4, P7, P8, O1, O2, Fz, Cz, Pz, Oz) arranged in accordance with the international 10–20 system [44] using a Brain Vision actiCap with…”
MethodCreaser, J. L., Storr, J., & Karl, A. (2022) · Frontiers in Psychology · doi:10.3389/fpsyg.2022.765602 · Cited by 9
Collaborative rule learning promotes interbrain information alignment
Moerel, D., Grootswagers, T., Quek, G. L., Smit, S., & Varlet, M. (2025) · PLOS Biology · doi:10.1371/journal.pbio.3003479 · Cited by 4
Metadata
- Authors
- Oostenveld, R., & Praamstra, P.
- Venue
- Clinical Neurophysiology
- Publisher
- Elsevier BV
- Published
- 2001-04
- Volume
- 112
- Issue
- 4
- Pages
- 713-719
- ISSN
- 1388-2457 (ISSN-L)
- OpenAlex
- W2105957367
- Cited by
- 1,909
- References
- 15
- FWCI
- 2.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.