The DOI matches its Crossref record.
Probing Proteomes Using Capillary Isoelectric Focusing-Electrospray Ionization Fourier Transform Ion Cyclotron Resonance Mass Spectrometry
Abstract
Unlike the genome, the proteome is exquisitely sensitive to cellular conditions and will consist of proteins having abundances dependent upon stage in the cell cycle, cell differentiation, response to environmental conditions (nutrients, temperature, stress etc.), or disease state(s). Therefore, the study of proteomes under well-defined conditions can provide a better understanding of complex biological processes and inference of protein function. Thus, much faster, more sensitive, and precise capabilities for the characterization of cellular constituents are desired. We describe progress in the development and initial application of the powerful combination of capillary isoelectric focusing (CIEF) and Fourier transform ion cyclotron resonance (FTICR) mass spectrometry for measurements of the proteome of the model system Escherichia coli. Isotope depletion of the growth media has been used to improve mass measurement accuracy, and the comparison of CIEF-FTICR results for the analysis of cell lysates harvested from E. coli cultured in normal and isotopically depleted media are presented. The initial studies have revealed 400-1000 putative proteins in the mass range 2-100 kDa from total injections of approximately 300 ng of E. coli proteins in a single CIEF-FTICR analysis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Proteomics to study genes and genomes
Pandey, A., & Mann, M. (2000) · Nature · doi:10.1038/35015709 · Cited by 2,373
Analysis of Proteins and Proteomes by Mass Spectrometry
Mann, M., Hendrickson, R. C., & Pandey, A. (2001) · Annual Review of Biochemistry · doi:10.1146/annurev.biochem.70.1.437 · Cited by 1,219
Electron Capture Dissociation for Structural Characterization of Multiply Charged Protein Cations
Zubarev, R. A., Horn, D. M., Fridriksson, E. K., Kelleher, N. L., Kruger, N. A., Lewis, M. A., Carpenter, B. K., & McLafferty, F. W. (2000) · Analytical Chemistry · doi:10.1021/ac990811p · Cited by 986
Analysis of protein phosphorylation using mass spectrometry: deciphering the phosphoproteome
Mann, M., Ong, S.-E., Grønborg, M., Steen, H., Jensen, O. N., & Pandey, A. (2002) · Trends in Biotechnology · doi:10.1016/s0167-7799(02)01944-3 · Cited by 900
Shevchenko, A., Sunyaev, S., Loboda, A., Shevchenko, A., Bork, P., Ens, W., & Standing, K. G. (2001) · Analytical Chemistry · doi:10.1021/ac0013709 · Cited by 582
Automated reduction and interpretation of
Horn, D. M., Zubarev, R. A., & McLafferty, F. W. (2000) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(99)00157-9 · Cited by 507
Top Down proteomics: Facts and perspectives
Catherman, A. D., Skinner, O. S., & Kelleher, N. L. (2014) · Biochemical and Biophysical Research Communications · doi:10.1016/j.bbrc.2014.02.041 · Cited by 507
“Improvements to the cIEF separation and data acquisition, as well as the use of isotopically-depleted growth media for improved sensitivity, allowed for the detection of 1,000 polypeptides/proteins from ~300 ng of protein [66,67].”
MethodProteomics by FTICR mass spectrometry: Top down and bottom up
Bogdanov, B., & Smith, R. D. (2005) · Mass Spectrometry Reviews · doi:10.1002/mas.20015 · Cited by 447
Self-citationGlobal analysis of the Deinococcus radiodurans proteome by using accurate mass tags
Lipton, M. S., Paša-Tolić, L., Anderson, G. A., Anderson, D. J., Auberry, D. L., Battista, J. R., Daly, M. J., Fredrickson, J., Hixson, K. K., Kostandarithes, H., et al. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.172170199 · Cited by 392
Self-citationAdvances in proteomics data analysis and display using an accurate mass and time tag approach
Zimmer, J. S. D., Monroe, M. E., Qian, W., & Smith, R. D. (2006) · Mass Spectrometry Reviews · doi:10.1002/mas.20071 · Cited by 304
Self-citation‘Top down’ protein characterization via tandem mass spectrometry
Reid, G. E., & McLuckey, S. A. (2002) · Journal of Mass Spectrometry · doi:10.1002/jms.346 · Cited by 285
Utility of Accurate Mass Tags for Proteome-Wide Protein Identification
Conrads, T. P., Anderson, G. A., Veenstra, T. D., Paša-Tolić, L., & Smith, R. D. (2000) · Analytical Chemistry · doi:10.1021/ac0002386 · Cited by 281
Self-citationMartin, S. E., Shabanowitz, J., Hunt, D. F., & Marto, J. A. (2000) · Analytical Chemistry · doi:10.1021/ac000497v · Cited by 276
Mischak, H., Coon, J. J., Novak, J., Weissinger, E. M., Schanstra, J. P., & Dominiczak, A. F. (2009) · Mass Spectrometry Reviews · doi:10.1002/mas.20205 · Cited by 193
Capillary electrophoresis–mass spectrometry for the analysis of intact proteins
Haselberg, R., de Jong, G. J., & Somsen, G. W. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.05.048 · Cited by 185
Lubeckyj, R. A., McCool, E. N., Shen, X., Kou, Q., Liu, X., & Sun, L. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b02532 · Cited by 96
Capillary electrophoresis applied to proteomic analysis
Fonslow, B. R., & Yates III, J. R. (2009) · Journal of Separation Science · doi:10.1002/jssc.200800592 · Cited by 92
CE‐MS‐based proteomics in biomarker discovery and clinical application
Pontillo, C., Filip, S., Borràs, D. M., Mullen, W., Vlahou, A., & Mischak, H. (2015) · PROTEOMICS – Clinical Applications · doi:10.1002/prca.201400115 · Cited by 77
Han, X., Wang, Y., Aslanian, A., Bern, M., Lavallée-Adam, M., & Yates, J. R. (2014) · Analytical Chemistry · doi:10.1021/ac503439n · Cited by 77
Zhao, Y., Sun, L., Champion, M. M., Knierman, M. D., & Dovichi, N. J. (2014) · Analytical Chemistry · doi:10.1021/ac500092q · Cited by 56
Zhao, Y., Riley, N. M., Sun, L., Hebert, A. S., Yan, X., Westphall, M. S., Rush, M. J. P., Zhu, G., Champion, M. M., Medie, F. M., et al. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b00883 · Cited by 55
Simplified capillary isoelectric focusing with chemical mobilization for intact protein analysis
Zhu, G., Sun, L., & Dovichi, N. J. (2017) · Journal of Separation Science · doi:10.1002/jssc.201601051 · Cited by 23
Jung, H. Y., Kim, D. W., Nam, S. M., Kim, J. W., Chung, J. Y., Won, M.-H., Seong, J. K., Yoon, Y. S., Yoo, D. Y., & Hwang, I. K. (2017) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/j.bbagen.2017.09.006 · Cited by 23
Metadata
- Authors
- Jensen, P. K., Paša-Tolić, L., Anderson, G. A., Horner, J. A., Lipton, M. S., Bruce, J. E., & Smith, R. D.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1999-05-04
- Volume
- 71
- Issue
- 11
- Pages
- 2076-2084
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2046557218
- Cited by
- 231
- References
- 0
- FWCI
- 18.34
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.