The DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
A Wearable Cellulose Acetate-Coated Mouthguard Biosensor for In Vivo Salivary Glucose Measurement
Abstract
In this study, a cellulose acetate (CA) membrane is formed as an interference rejection membrane on a glucose sensor to measure glucose in saliva. Glucose in saliva is successfully measured in vivo without any pretreatment of human saliva. A mouthguard (MG) glucose sensor is developed to monitor salivary glucose, which is reported to be correlated with the blood glucose level. Salivary components of ascorbic acid (AA) and uric acid (UA) hinder the accurate measurement of the glucose concentration of human saliva. CA-coated electrodes are prepared to investigate the interference rejection membrane. To measure hydrogen peroxide, which is a reaction product of glucose oxidase, effects of AA and UA are examined. Characteristics of the fabricated biosensor are examined on the basis of artificial saliva. The as-developed MG sensor can quantify the glucose concentration in the range of 1.75-10 000 μmol/L, which includes a salivary sugar concentration of 20-200 μmol/L. For the measurement of saliva samples collected from healthy subjects, the output corresponding to the concentration is confirmed; this suggests the possibility of glucose measurement. This MG glucose sensor can provide a useful method for the unrestricted and noninvasive monitoring of saliva glucose for the management of diabetes patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Forouzanfar, M. H., Afshin, A., Alexander, L. T., Anderson, H. R., Bhutta, Z. A., Biryukov, S., Brauer, M., Burnett, R., Cercy, K., Charlson, F. J., et al. (2016) · The Lancet · doi:10.1016/s0140-6736(16)31679-8 · Cited by 7,698
Wearable biosensors for healthcare monitoring
Kim, J., Campbell, A. S., de Ávila, B. E.-F., & Wang, J. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0045-y · Cited by 3,373
The worldwide epidemiology of type 2 diabetes mellitus—present and future perspectives
Chen, L., Magliano, D. J., & Zimmet, P. Z. (2012) · Nature Reviews Endocrinology · doi:10.1038/nrendo.2011.183 · Cited by 2,227
Glucose Transporters and Insulin Action — Implications for Insulin Resistance and Diabetes Mellitus
Shepherd, P. R., & Kahn, B. B. (1999) · New England Journal of Medicine · doi:10.1056/nejm199907223410406 · Cited by 1,295
Non-invasive wearable electrochemical sensors: a review
Bandodkar, A. J., & Wang, J. (2014) · Trends in Biotechnology · doi:10.1016/j.tibtech.2014.04.005 · Cited by 1,247
Lee, H., Song, C., Hong, Y. S., Kim, M., Cho, H. R., Kang, T., Shin, K., Choi, S. H., Hyeon, T., & Kim, D.-H. (2017) · Science Advances · doi:10.1126/sciadv.1601314 · Cited by 1,118
Electrochemical Tattoo Biosensors for Real-Time Noninvasive Lactate Monitoring in Human Perspiration
Jia, W., Bandodkar, A. J., Valdés-Ramírez, G., Windmiller, J. R., Yang, Z., Ramírez, J., Chan, G., & Wang, J. (2013) · Analytical Chemistry · doi:10.1021/ac401573r · Cited by 862
Glucose Sensing for Diabetes Monitoring: Recent Developments
Bruen, D., Delaney, C., Florea, L., & Diamond, D. (2017) · Sensors · doi:10.3390/s17081866 · Cited by 777
Tattoo-Based Noninvasive Glucose Monitoring: A Proof-of-Concept Study
Bandodkar, A. J., Jia, W., Yardımcı, C., Wang, X., Ramirez, J., & Wang, J. (2015) · Analytical Chemistry · doi:10.1021/ac504300n · Cited by 700
The Performance and Usability of a Factory-Calibrated Flash Glucose Monitoring System
Bailey, T., Bode, B. W., Christiansen, M. P., Klaff, L. J., & Alva, S. (2015) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2014.0378 · Cited by 685
Wearable salivary uric acid mouthguard biosensor with integrated wireless electronics
Kim, J., Imani, S., de Araujo, W. R., Warchall, J., Valdés-Ramírez, G., Paixão, T. R. L. C., Mercier, P. P., & Wang, J. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.07.039 · Cited by 678
Wearable non-invasive epidermal glucose sensors: A review
Kim, J., Campbell, A. S., & Wang, J. (2018) · Talanta · doi:10.1016/j.talanta.2017.08.077 · Cited by 586
Biocompatibility of dental casting alloys: A review
Wataha, J. C. (2000) · The Journal of Prosthetic Dentistry · doi:10.1016/s0022-3913(00)80016-5 · Cited by 514
Non-invasive mouthguard biosensor for continuous salivary monitoring of metabolites
Kim, J., Valdés-Ramírez, G., Bandodkar, A. J., Jia, W., Martinez, A. G., Ramírez, J., Mercier, P., & Wang, J. (2014) · The Analyst · doi:10.1039/c3an02359a · Cited by 367
Mouthguard biosensor with telemetry system for monitoring of saliva glucose: A novel cavitas sensor
Arakawa, T., Kuroki, Y., Nitta, H., Chouhan, P., Toma, K., Sawada, S.-I., Takeuchi, S., Sekita, T., Akiyoshi, K., Minakuchi, S., et al. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.12.014 · Cited by 356
Self-citationIwasaki, Y., & Ishihara, K. (2012) · Science and Technology of Advanced Materials · doi:10.1088/1468-6996/13/6/064101 · Cited by 346
Recent advances in cortisol sensing technologies for point-of-care application
Kaushik, A., Vasudev, A., Arya, S. K., Pasha, S. K., & Bhansali, S. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.09.060 · Cited by 316
Eyeglasses based wireless electrolyte and metabolite sensor platform
Sempionatto, J. R., Nakagawa, T., Pavinatto, A., Mensah, S. T., Imani, S., Mercier, P., & Wang, J. (2017) · Lab on a Chip · doi:10.1039/c7lc00192d · Cited by 311
Corrosion of Gold and Amalgam Placed in Contact with Each other
Fusayama, T., Katayori, T., & Nomoto, S. (1963) · Journal of Dental Research · doi:10.1177/00220345630420051301 · Cited by 295
Karpova, E. V., Shcherbacheva, E. V., Galushin, A. A., Vokhmyanina, D. V., Karyakina, E. E., & Karyakin, A. A. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.8b05928 · Cited by 242
Pacifier Biosensor: Toward Noninvasive Saliva Biomarker Monitoring
García-Carmona, L., Martín, A., Sempionatto, J. R., Moreto, J. R., González, M. C., Wang, J., & Escarpa, A. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b03379 · Cited by 230
Corrie, S. R., Coffey, J. W., Islam, J., Markey, K. A., & Kendall, M. A. F. (2015) · The Analyst · doi:10.1039/c5an00464k · Cited by 211
de Castro, L. F., de Freitas, S. V., Duarte, L. C., de Souza, J. A. C., Paixão, T. R. L. C., & Coltro, W. K. T. (2019) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-019-01788-0 · Cited by 184
Nonenzymatic Sensor for Lactate Detection in Human Sweat
Zaryanov, N. V., Nikitina, V. N., Karpova, E. V., Karyakina, E. E., & Karyakin, A. A. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b03662 · Cited by 160
Diabetes in Japan: a review of disease burden and approaches to treatment
Neville, S. E., Boye, K. S., Montgomery, W. S., Iwamoto, K., Okamura, M., & Hayes, R. P. (2009) · Diabetes/Metabolism Research and Reviews · doi:10.1002/dmrr.1012 · Cited by 152
Smartphone-based sensing system using ZnO and graphene modified electrodes for VOCs detection
Liu, L., Zhang, D., Zhang, Q. Y., Chen, X., Xu, G., Lu, Y., & Liu, Q. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.09.084 · Cited by 119
Immunologic and Tissue Biocompatibility of Flexible/Stretchable Electronics and Optoelectronics
Park, G., Chung, H., Kim, K., Lim, S. A., Kim, J., Kim, Y., Liu, Y., Yeo, W., Kim, R.-H., Kim, S. S., et al. (2013) · Advanced Healthcare Materials · doi:10.1002/adhm.201300220 · Cited by 116
Ilea, A., Andrei, V., Feurdean, C. N., Băbțan, A.-M., Petrescu, N. B., Câmpian, R. S., Boşca, A. B., Ciui, B., Tertiş, M., Săndulescu, R., et al. (2019) · Biosensors · doi:10.3390/bios9010027 · Cited by 114
A Wearable Paper‐Based Sweat Sensor for Human Perspiration Monitoring
Parrilla, M., Guinovart, T., Ferré, J. F., Blondeau, P., & Andrade, F. J. (2019) · Advanced Healthcare Materials · doi:10.1002/adhm.201900342 · Cited by 114
Ye, M., Chien, P.-J., Toma, K., Arakawa, T., & Mitsubayashi, K. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.04.023 · Cited by 109
Self-citationBiomedical soft contact-lens sensor for in situ ocular biomonitoring of tear contents
Chu, M., Shirai, T., Takahashi, D., Arakawa, T., Kudo, H., Sano, K., Sawada, S.-I., Yano, K., Iwasaki, Y., Akiyoshi, K., et al. (2011) · Biomedical Microdevices · doi:10.1007/s10544-011-9530-x · Cited by 85
Self-citationChien, P.-J., Suzuki, T., Tsujii, M., Ye, M., Minami, I., Toda, K., Otsuka, H., Toma, K., Arakawa, T., Araki, K., et al. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b03191 · Cited by 79
Self-citationRecent trends in the development of diagnostic tools for diabetes mellitus using patient saliva
Viswanath, B., Choi, C. S., Lee, K., & Kim, S. (2017) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2017.01.011 · Cited by 75
Miyashita, M., Ito, N., Ikeda, S., Murayama, T., Oguma, K., & Kimura, J. (2008) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2008.07.072 · Cited by 75
Cavitas Sensors: Contact Lens Type Sensors & Mouthguard Sensors
Mitsubayashi, K., & Arakawa, T. (2016) · Electroanalysis · doi:10.1002/elan.201600083 · Cited by 71
Self-citationAn On-Chip Disposable Salivary Glucose Sensor for Diabetes Control
Du, Y., Zhang, W., & Wang, M. (2016) · Journal of Diabetes Science and Technology · doi:10.1177/1932296816642251 · Cited by 58
Salivary glucose as a non-invasive biomarker of type 2 diabetes mellitus
Tiongco, R. E., Bituin, A., Arceo, E. S., Rivera, N., & Singian, E. (2018) · Journal of Clinical and Experimental Dentistry · doi:10.4317/jced.55009 · Cited by 53
Reverse Iontophoresis for Noninvasive Glucose Monitoring: The Internal Standard Concept
Sieg, A., Guy, R. H., & Delgado-Charro, M. B. (2003) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.10492 · Cited by 45
Yamada, Y., Hiyama, S., Toyooka, T., Takeuchi, S., Itabashi, K., Okubo, T., & Tabata, H. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b00296 · Cited by 40
Self-citationManaging diabetes through the skin
Guy, R. H. (2016) · Nature Nanotechnology · doi:10.1038/nnano.2016.53 · Cited by 31
Cited by
Device integration of electrochemical biosensors
Wu, J., Liu, H., Chen, W., Ma, B., & Ju, H. (2023) · Nature Reviews Bioengineering · doi:10.1038/s44222-023-00032-w · Cited by 895
Flexible Wearable Sensors for Cardiovascular Health Monitoring
Chen, S., Qi, J., Fan, S., Qiao, Z., Yeo, J. C., & Lim, C. T. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202100116 · Cited by 453
Wearable Electrochemical Glucose Sensors in Diabetes Management: A Comprehensive Review
Saha, T., Del Caño, R., Mahato, K., De la Paz, E., Chen, C., Ding, S., Yin, L., & Wang, J. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00078 · Cited by 442
Applied body-fluid analysis by wearable devices
Brasier, N., Wang, J., Gao, W., Sempionatto, J. R., Dincer, C., Ates, H. C., Güder, F., Olenik, S., Schauwecker, I., Schaffarczyk, D., et al. (2024) · Nature · doi:10.1038/s41586-024-08249-4 · Cited by 298
AI-Assisted Detection of Biomarkers by Sensors and Biosensors for Early Diagnosis and Monitoring
Wasilewski, T., Kamysz, W., & Gębicki, J. (2024) · Biosensors · doi:10.3390/bios14070356 · Cited by 290
Metadata
- Authors
- Arakawa, T., Tomoto, K., Nitta, H., Toma, K., Takeuchi, S., Sekita, T., Minakuchi, S., & Mitsubayashi, K.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2020-08-11
- Volume
- 92
- Issue
- 18
- Pages
- 12201-12207
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W3048679509
- Cited by
- 313
- References
- 40
- FWCI
- 10.97
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.