State of Sweat: Emerging Wearable Systems for Real-Time, Noninvasive Sweat Sensing and Analytics
Open accessThe DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Abstract
Skin-interfaced wearable systems with integrated colorimetric assays, microfluidic channels, and electrochemical sensors offer powerful capabilities for noninvasive, real-time sweat analysis. This Perspective details recent progress in the development and translation of novel wearable sensors for personalized assessment of sweat dynamics and biomarkers, with precise sampling and real-time analysis. Sensor accuracy, system ruggedness, and large-scale deployment in remote environments represent key opportunity areas, enabling broad deployment in the context of field studies, clinical trials, and recent commercialization. On-body measurements in these contexts show good agreement compared to conventional laboratory-based sweat analysis approaches. These device demonstrations highlight the utility of biochemical sensing platforms for personalized assessment of performance, wellness, and health across a broad range of applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gibson, L. E., & Cooke, R. E. (1959) · Pediatrics · doi:10.1542/peds.23.3.545 · Cited by 1,434 · cited 1×
“Established clinically in 1959 148 , quantitative evaluation of sweat chloride in neonates remains the only widely available method for confirmatory diagnosis of cystic fibrosis.”
Bio-Integrated Wearable Systems: A Comprehensive Review
Ray, T. R., Choi, J., Bandodkar, A. J., Krishnan, S., Gutruf, P., Tian, L., Ghaffari, R., & Rogers, J. A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00573 · Cited by 1,350
Self-citationWearable and flexible electronics for continuous molecular monitoring
Yang, Y., & Gao, W. (2019) · Chemical Society Reviews · doi:10.1039/c7cs00730b · Cited by 1,315
A soft, wearable microfluidic device for the capture, storage, and colorimetric sensing of sweat
Koh, A., Kang, D., Xue, Y., Lee, S., Pielak, R. M., Kim, J., Hwang, T., Min, S., Banks, A., Bastien, P., et al. (2016) · Science Translational Medicine · doi:10.1126/scitranslmed.aaf2593 · Cited by 1,308
Self-citationA laser-engraved wearable sensor for sensitive detection of uric acid and tyrosine in sweat
Yang, Y., Song, Y., Bo, X., Min, J., Pak, O. S., Zhu, L., Wang, M., Tu, J., Kogan, A., Zhang, H., et al. (2020) · Nature Biotechnology · doi:10.1038/s41587-019-0321-x · Cited by 1,270 · cited 1×
“Recent examples of wearable electrochemical sensing platforms demonstrate the promise of sweat analytics for monitoring biomolecular changes relevant to diseases such as gout 142 (uric acid, Fig.”
Progress in evidence-based medicine: a quarter century on
Djulbegovic, B., & Guyatt, G. H. (2017) · The Lancet · doi:10.1016/s0140-6736(16)31592-6 · Cited by 1,022 · cited 1×
“The shifting paradigm in clinical practice to an evidence-based care underscores the critical need for an expanded suite of capabilities for the rapid and continuous assessment of digital and metabolic biomarkers relevant to human health 1,2 .”
An epidermal patch for the simultaneous monitoring of haemodynamic and metabolic biomarkers
Sempionatto, J. R., Lin, M., Yin, L., De la paz, E., Pei, K., Sonsa-ard, T., de Loyola Silva, A. N., Khorshed, A. A., Zhang, F., Tostado, N., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00685-1 · Cited by 658
Yu, Y., Nassar, J., Xu, C., Min, J., Yang, Y., Dai, A., Doshi, R., Huang, A., Song, Y., Gehlhar, R., et al. (2020) · Science Robotics · doi:10.1126/scirobotics.aaz7946 · Cited by 655
Wireless battery-free wearable sweat sensor powered by human motion
Song, Y., Min, J., Yu, Y., Wang, H., Yang, Y., Zhang, H., & Gao, W. (2020) · Science Advances · doi:10.1126/sciadv.aay9842 · Cited by 652
Investigation of Cortisol Dynamics in Human Sweat Using a Graphene-Based Wireless mHealth System
Torrente-Rodríguez, R. M., Tu, J., Yang, Y., Min, J., Wang, M., Song, Y., Yu, Y., Xu, C., Ye, C., IsHak, W. W., et al. (2020) · Matter · doi:10.1016/j.matt.2020.01.021 · Cited by 479 · cited 1×
“Other wearable sensor designs seek to harness blood-correlated biomarkers beyond chloride and glucose (e.g. lactate 161-165 , ethanol 156 , cortisol 166,167 ) to address diagnostic challenges related to diabetes and other diseases.”
A wearable patch for continuous analysis of thermoregulatory sweat at rest
Nyein, H. Y. Y., Bariya, M., Tran, B., Ahn, C. H., Brown, B. J., Ji, W., Davis, N., & Javey, A. (2021) · Nature Communications · doi:10.1038/s41467-021-22109-z · Cited by 437 · cited 1×
“Another recent demonstration device 146 (Fig.”
Skin-interfaced systems for sweat collection and analytics
Choi, J., Ghaffari, R., Baker, L. B., & Rogers, J. A. (2018) · Science Advances · doi:10.1126/sciadv.aar3921 · Cited by 433
Self-citationBaker, L. B. (2017) · Sports Medicine · doi:10.1007/s40279-017-0691-5 · Cited by 403
Nyein, H. Y. Y., Bariya, M., Kivimäki, L., Uusitalo, S., Liaw, T. S., Jansson, E., Ahn, C. H., Hangasky, J. A., Zhao, J., Lin, Y., et al. (2019) · Science Advances · doi:10.1126/sciadv.aaw9906 · Cited by 388
Wearable Sensors for Biochemical Sweat Analysis
Bandodkar, A. J., Jeang, W. J., Ghaffari, R., & Rogers, J. A. (2019) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-061318-114910 · Cited by 387 · cited 2×
“Although the performance of these sensing platforms has been extensively validated for a variety of biomolecular targets and sensor architectures 23,43 , there is an absence of studies correlating regional measurements from such wearable sensors and the whole-body sweat response.”
Self-citationWearable flexible sweat sensors for healthcare monitoring: a review
Chung, M., Fortunato, G., & Radacsi, N. (2019) · Journal of The Royal Society Interface · doi:10.1098/rsif.2019.0217 · Cited by 378
Physiological mechanisms determining eccrine sweat composition
Baker, L. B., & Wolfe, A. S. (2020) · European Journal of Applied Physiology · doi:10.1007/s00421-020-04323-7 · Cited by 367 · cited 3×
“Intense physical activity, exposure to heat stress, and localized chemical inducement are the core methods for generating sufficient microliter volumes of sweat for biochemical analysis with suitability defined by target application 16,100-104 .”
Choi, J., Bandodkar, A. J., Reeder, J. T., Ray, T. R., Turnquist, A., Kim, S. B., Nyberg, N., Hourlier-Fargette, A., Model, J. B., Aranyosi, A. J., et al. (2019) · ACS Sensors · doi:10.1021/acssensors.8b01218 · Cited by 365
Self-citationMethylxanthine Drug Monitoring with Wearable Sweat Sensors
Tai, L., Gao, W., Chao, M., Bariya, M., Ngo, Q. P., Shahpar, Z., Nyein, H. Y. Y., Park, H., Sun, J., Jung, Y., et al. (2018) · Advanced Materials · doi:10.1002/adma.201707442 · Cited by 310
Reeder, J. T., Choi, J., Xue, Y., Gutruf, P., Hanson, J., Liu, M., Ray, T., Bandodkar, A. J., Avila, R., Xia, W., et al. (2019) · Science Advances · doi:10.1126/sciadv.aau6356 · Cited by 308
Self-citationSekine, Y., Kim, S. B., Zhang, Y., Bandodkar, A. J., Xu, S., Choi, J., Irie, M., Ray, T. R., Kohli, P., Kozai, N., et al. (2018) · Lab on a Chip · doi:10.1039/c8lc00530c · Cited by 242
Self-citationSelf-Powered Wearable Biosensors
Song, Y., Mukasa, D., Zhang, H., & Gao, W. (2021) · Accounts of Materials Research · doi:10.1021/accountsmr.1c00002 · Cited by 237
Kwon, K., Kim, J. U., Deng, Y., Krishnan, S. R., Choi, J., Jang, H., Lee, K., Su, C.-J., Yoo, I., Wu, Y., et al. (2021) · Nature Electronics · doi:10.1038/s41928-021-00556-2 · Cited by 230
Self-citationAchievements and Challenges for Real-Time Sensing of Analytes in Sweat within Wearable Platforms
Brothers, M. C., DeBrosse, M., Grigsby, C. C., Naik, R. R., Hussain, S. M., Heikenfeld, J., & Kim, S. S. (2019) · Accounts of Chemical Research · doi:10.1021/acs.accounts.8b00555 · Cited by 207
Hauke, A., Simmers, P., Ojha, Y. R., Cameron, B. D., Ballweg, R., Zhang, T., Twine, N., Brothers, M., Gomez, E., & Heikenfeld, J. (2018) · Lab on a Chip · doi:10.1039/c8lc01082j · Cited by 156 · cited 2×
“Other wearable sensor designs seek to harness blood-correlated biomarkers beyond chloride and glucose (e.g. lactate 161-165 , ethanol 156 , cortisol 166,167 ) to address diagnostic challenges related to diabetes and other diseases.”
Glove-based sensors for multimodal monitoring of natural sweat
Bariya, M., Li, L., Ghattamaneni, R., Ahn, C. H., Nyein, H. Y. Y., Tai, L.-C., & Javey, A. (2020) · Science Advances · doi:10.1126/sciadv.abb8308 · Cited by 154
Lee, H.-B., Meeseepong, M., Trung, T. Q., Kim, B.-Y., & Lee, N.-E. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112133 · Cited by 153 · cited 2×
“In addition to fluid and chloride loss, the concentration of glucose 125,134 , lactate 135,136 , ammonia 137 , and cortisol 138 in sweat have value for monitoring athletic training and conditioning.”
A passive perspiration biofuel cell: High energy return on investment
Yin, L., Moon, J.-M., Sempionatto, J. R., Lin, M., Cao, M., Trifonov, A., Zhang, F., Lou, Z., Jeong, J.-M., Lee, S.-J., et al. (2021) · Joule · doi:10.1016/j.joule.2021.06.004 · Cited by 134
Stress Monitoring and Recent Advancements in Wearable Biosensors
Samson, C., & Koh, A. (2020) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2020.01037 · Cited by 129
Baker, L. B., Ungaro, C. T., Sopeña, B. C., Nuccio, R. P., Reimel, A. J., Carter, J. M., Stofan, J. R., & Barnes, K. A. (2018) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00867.2017 · Cited by 116 · cited 1×
“Practitioners and athletes typically estimate whole-body sweat loss by recording changes in body mass after physical activity 103 .”
Comparison of Colorimetric Analyses to Determine Cortisol in Human Sweat
Tu, E., Pearlmutter, P., Tiangco, M., Derose, G., Begdache, L., & Koh, A. (2020) · ACS Omega · doi:10.1021/acsomega.0c00498 · Cited by 90
Eccrine Sweat as a Biofluid for Profiling Immune Biomarkers
Katchman, B. A., Zhu, M., Blain Christen, J., & Anderson, K. S. (2018) · PROTEOMICS – Clinical Applications · doi:10.1002/prca.201800010 · Cited by 86 · cited 2×
“Intense physical activity, exposure to heat stress, and localized chemical inducement are the core methods for generating sufficient microliter volumes of sweat for biochemical analysis with suitability defined by target application 16,100-104 .”
Wearable sweat sensing for prolonged, semicontinuous, and nonobtrusive health monitoring
Moonen, E. J. M., Haakma, J. R., Peri, E., Pelssers, E., Mischi, M., & den Toonder, J. M. J. (2020) · VIEW · doi:10.1002/viw.20200077 · Cited by 86
Sweat test for cystic fibrosis: Wearable sweat sensor vs. standard laboratory test
Choi, D.-H., Thaxton, A., Jeong, I. C., Kim, K., Sosnay, P. R., Cutting, G. R., & Searson, P. C. (2018) · Journal of Cystic Fibrosis · doi:10.1016/j.jcf.2018.03.005 · Cited by 80 · cited 1×
“Another embodiment 149 integrates a salt-bridge based potentiometric sensor with wireless Bluetooth communications to monitor sweat chloride concentration from a smartphone in real-time during exercise.”
Ultra-simple wearable local sweat volume monitoring patch based on swellable hydrogels
Zhao, F. J., Bonmarin, M., Chen, Z. C., Larson, M., Fay, D., Runnoe, D., & Heikenfeld, J. (2020) · Lab on a Chip · doi:10.1039/c9lc00911f · Cited by 71
Choi, J., Chen, S., Deng, Y., Xue, Y., Reeder, J. T., Franklin, D., Oh, Y. S., Model, J. B., Aranyosi, A. J., Lee, S. P., et al. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202000722 · Cited by 67
Modeling Glucose Transport From Systemic Circulation to Sweat
La Count, T. D., Jajack, A., Heikenfeld, J., & Kasting, G. B. (2019) · Journal of Pharmaceutical Sciences · doi:10.1016/j.xphs.2018.09.026 · Cited by 60
Enhancing glucose flux into sweat by increasing paracellular permeability of the sweat gland
Jajack, A., Brothers, M., Kasting, G., & Heikenfeld, J. (2018) · PLOS ONE · doi:10.1371/journal.pone.0200009 · Cited by 35
Souza, S. L., Graça, G., & Oliva, A. (2018) · Skin Research and Technology · doi:10.1111/srt.12412 · Cited by 34 · cited 1×
“For a given sensing application, a key consideration in tandem with mode of deployment (ambulatory vs. stationary individual) is the dependence of both the rate of sweat production 105 and biochemical composition 100,106,107 on the stimulation method.”
Measurement of sodium concentration in sweat samples: comparison of 5 analytical techniques
Goulet, E. D. B., Asselin, A., Gosselin, J., & Baker, L. B. (2017) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/apnm-2017-0059 · Cited by 28
Cited by
Skin bioelectronics towards long-term, continuous health monitoring
Wang, Y., Haick, H., Guo, S., Wang, C., Lee, S., Yokota, T., & Someya, T. (2022) · Chemical Society Reviews · doi:10.1039/d2cs00207h · Cited by 318
Reshaping healthcare with wearable biosensors
Smith, A. A., Li, R., & Tse, Z. T. H. (2023) · Scientific Reports · doi:10.1038/s41598-022-26951-z · Cited by 267
Sweat as a diagnostic biofluid
Yang, D. S., Ghaffari, R., & Rogers, J. A. (2023) · Science · doi:10.1126/science.abq5916 · Cited by 200
Self-citation
Metadata
- Authors
- Ghaffari, R., Yang, D. S., Kim, J., Mansour, A., Wright, J. A., Model, J. B., Wright, D. E., Rogers, J. A., & Ray, T. R.
- Venue
- ACS Sensors
- Publisher
- American Chemical Society (ACS)
- Published
- 2021-08-05
- Volume
- 6
- Issue
- 8
- Pages
- 2787-2801
- ISSN
- 2379-3694 (ISSN-L)
- OpenAlex
- W3189520890
- Cited by
- 178
- References
- 40
- FWCI
- 7.35
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.