The DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.
A Wearable Microfluidic Sensing Patch for Dynamic Sweat Secretion Analysis
Open accessAbstract
Wearable sweat sensing is a rapidly rising research area driven by its promising potential in health, fitness, and diagnostic applications. Despite the growth in the field, major challenges in relation to sweat metrics remain to be addressed. These challenges include sweat rate monitoring for its complex relation with sweat compositions and sweat sampling for sweat dynamics studies. In this work, we present a flexible microfluidic sweat sensing patch that enhances real-time electrochemical sensing and sweat rate analysis via sweat sampling. The device contains a spiral-patterned microfluidic component that is embedded with ion-selective sensors and an electrical impedance-based sweat rate sensor on a flexible plastic substrate. The patch is enabled to autonomously perform sweat analysis by interfacing the sensing component with a printed circuit board that is capable of on-site signal conditioning, analysis, and transmission. Progressive sweat flow in the microfluidic device, governed by the pressure induced by the secreted sweat, enhances sweat sampling and electrochemical detection via a defined sweat collection chamber and a directed sweat route. The characteristic of the sweat rate sensor is validated through a theoretical simulation, and the precision and accuracy of the flow rate is verified with a commercial syringe pump and a Macroduct sweat collector. On-body simultaneous monitoring of ion (H +, Na +, K +, Cl – ) concentration and sweat rate is also demonstrated for sensor functionality. This sweat sensing patch provides an integrated platform for a comprehensive sweat secretion analysis and facilitates physiological and clinical investigations by closely monitoring interrelated sweat parameters.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087
Self-citationAn ultra-lightweight design for imperceptible plastic electronics
Kaltenbrunner, M., Sekitani, T., Reeder, J., Yokota, T., Kuribara, K., Tokuhara, T., Drack, M., Schwödiauer, R., Graz, I., Bauer-Gogonea, S., et al. (2013) · Nature · doi:10.1038/nature12314 · Cited by 2,485
Schwartz, G., Tee, B. C.-K., Mei, J., Appleton, A. L., Kim, D. H., Wang, H., & Bao, Z. (2013) · Nature Communications · doi:10.1038/ncomms2832 · Cited by 2,042
A soft, wearable microfluidic device for the capture, storage, and colorimetric sensing of sweat
Koh, A., Kang, D., Xue, Y., Lee, S., Pielak, R. M., Kim, J., Hwang, T., Min, S., Banks, A., Bastien, P., et al. (2016) · Science Translational Medicine · doi:10.1126/scitranslmed.aaf2593 · Cited by 1,308
Soft Microfluidic Assemblies of Sensors, Circuits, and Radios for the Skin
Xu, S., Zhang, Y., Jia, L., Mathewson, K. E., Jang, K.-I., Kim, J., Fu, H., Huang, X., Chava, P., Wang, R., et al. (2014) · Science · doi:10.1126/science.1250169 · Cited by 1,199
User-interactive electronic skin for instantaneous pressure visualization
Wang, C., Hwang, D., Yu, Z., Takei, K., Park, J., Chen, T., Ma, B., & Javey, A. (2013) · Nature Materials · doi:10.1038/nmat3711 · Cited by 1,182
Self-citationA skin-inspired organic digital mechanoreceptor
Tee, B. C.-K., Chortos, A., Berndt, A., Nguyen, A. K., Tom, A., McGuire, A., Lin, Z. C., Tien, K., Bae, W.-G., Wang, H., et al. (2015) · Science · doi:10.1126/science.aaa9306 · Cited by 882
Emaminejad, S., Gao, W., Wu, E., Davies, Z. A., Yin Yin Nyein, H., Challa, S., Ryan, S. P., Fahad, H. M., Chen, K., Shahpar, Z., et al. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1701740114 · Cited by 839
Self-citationWearable Chemical Sensors: Present Challenges and Future Prospects
Bandodkar, A. J., Jeerapan, I., & Wang, J. (2016) · ACS Sensors · doi:10.1021/acssensors.6b00250 · Cited by 778
Sonner, Z., Wilder, E., Heikenfeld, J., Kasting, G., Beyette, F., Swaile, D., Sherman, F., Joyce, J., Hagen, J., Kelley-Loughnane, N., et al. (2015) · Biomicrofluidics · doi:10.1063/1.4921039 · Cited by 724
A Wearable Electrochemical Platform for Noninvasive Simultaneous Monitoring of Ca2+ and pH
Nyein, H. Y. Y., Gao, W., Shahpar, Z., Emaminejad, S., Challa, S., Chen, K., Fahad, H. M., Tai, L.-C., Ota, H., Davis, R. W., et al. (2016) · ACS Nano · doi:10.1021/acsnano.6b04005 · Cited by 669
Self-citationWearable Microfluidic Diaphragm Pressure Sensor for Health and Tactile Touch Monitoring
Gao, Y., Ota, H., Schaler, E. W., Chen, K., Zhao, A., Gao, W., Fahad, H. M., Leng, Y., Zheng, A., Xiong, F., et al. (2017) · Advanced Materials · doi:10.1002/adma.201701985 · Cited by 614
Self-citationNoninvasive Alcohol Monitoring Using a Wearable Tattoo-Based Iontophoretic-Biosensing System
Kim, J., Jeerapan, I., Imani, S., Cho, T. N., Bandodkar, A., Cinti, S., Mercier, P. P., & Wang, J. (2016) · ACS Sensors · doi:10.1021/acssensors.6b00356 · Cited by 599
Martín, A., Kim, J., Kurniawan, J. F., Sempionatto, J. R., Moreto, J. R., Tang, G., Campbell, A. S., Shin, A., Lee, M. Y., Liu, X., et al. (2017) · ACS Sensors · doi:10.1021/acssensors.7b00729 · Cited by 475
A wearable multisensing patch for continuous sweat monitoring
Anastasova, S., Crewther, B., Bembnowicz, P., Curto, V., Ip, H. M., Rosa, B., & Yang, G.-Z. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.09.038 · Cited by 443
Li, X., Dunn, J., Salins, D., Zhou, G., Zhou, W., Schüssler-Fiorenza Rose, S. M., Perelman, D., Colbert, E., Runge, R., Rego, S., et al. (2017) · PLOS Biology · doi:10.1371/journal.pbio.2001402 · Cited by 431
Adhesive RFID Sensor Patch for Monitoring of Sweat Electrolytes
Rose, D. P., Ratterman, M. E., Griffin, D. K., Hou, L., Kelley-Loughnane, N., Naik, R. R., Hagen, J. A., Papautsky, I., & Heikenfeld, J. C. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2369991 · Cited by 416
Wearable Microsensor Array for Multiplexed Heavy Metal Monitoring of Body Fluids
Gao, W., Nyein, H. Y. Y., Shahpar, Z., Fahad, H. M., Chen, K., Emaminejad, S., Gao, Y., Tai, L.-C., Ota, H., Wu, E., et al. (2016) · ACS Sensors · doi:10.1021/acssensors.6b00287 · Cited by 391
Self-citationNon‐invasive Analyte Access and Sensing through Eccrine Sweat: Challenges and Outlook circa 2016
Heikenfeld, J. (2016) · Electroanalysis · doi:10.1002/elan.201600018 · Cited by 294
A wearable electrochemical sensor for the real-time measurement of sweat sodium concentration
Schazmann, B., Morris, D., Slater, C., Beirne, S., Fay, C., Reuveny, R., Moyna, N., & Diamond, D. (2010) · Analytical Methods · doi:10.1039/b9ay00184k · Cited by 286
A facile route for irreversible bonding of plastic-PDMS hybrid microdevices at room temperature
Tang, L., & Lee, N. Y. (2010) · Lab on a Chip · doi:10.1039/b924753j · Cited by 267
Gavish, N., & Promislow, K. (2016) · Physical Review E · doi:10.1103/physreve.94.012611 · Cited by 253
Shirreffs, S. M., & Maughan, R. J. (1997) · Journal of Applied Physiology · doi:10.1152/jappl.1997.82.1.336 · Cited by 251
Portable biosensor for monitoring cortisol in low-volume perspired human sweat
Kinnamon, D., Ghanta, R., Lin, K.-C., Muthukumar, S., & Prasad, S. (2017) · Scientific Reports · doi:10.1038/s41598-017-13684-7 · Cited by 231
Flexible Substrate-Based Devices for Point-of-Care Diagnostics
Wang, S., Chinnasamy, T., Lifson, M. A., Inci, F., & Demirci, U. (2016) · Trends in Biotechnology · doi:10.1016/j.tibtech.2016.05.009 · Cited by 209
Sodium ion concentration vs. sweat rate relationship in humans
Buono, M. J., Ball, K. D., & Kolkhorst, F. W. (2007) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00015.2007 · Cited by 186
Hammond, K. B., Turcios, N. L., & Gibson, L. E. (1994) · The Journal of Pediatrics · doi:10.1016/s0022-3476(94)70314-0 · Cited by 178
The Current Status of Sweat Testing For Drugs of Abuse: A Review
De Giovanni, N., & Fucci, N. (2013) · Current Medicinal Chemistry · doi:10.2174/092986713804910139 · Cited by 164
Soft, thin skin-mounted power management systems and their use in wireless thermography
Lee, J. W., Xu, R., Lee, S., Jang, K.-I., Yang, Y., Banks, A., Yu, K. J., Kim, J., Xu, S., Ma, S., et al. (2016) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1605720113 · Cited by 162
Relationship between Lactate Concentrations in Active Muscle Sweat and Whole Blood
Sakharov, D. A., Shkurnikov, M. Y., Vagin, M. Y., Yashina, E. I., Karyakin, A. A., & Tonevitsky, A. (2010) · Bulletin of Experimental Biology and Medicine · doi:10.1007/s10517-010-1075-0 · Cited by 155
3D Printed “Earable” Smart Devices for Real-Time Detection of Core Body Temperature
Ota, H., Chao, M., Gao, Y., Wu, E., Tai, L.-C., Chen, K., Matsuoka, Y., Iwai, K., Fahad, H. M., Gao, W., et al. (2017) · ACS Sensors · doi:10.1021/acssensors.7b00247 · Cited by 154
Self-citationA Wearable Sensor for Measuring Sweat Rate
Salvo, P., Francesco, F. D., Costanzo, D., Ferrari, C., Trivella, M. G., & Rossi, D. D. (2010) · IEEE Sensors Journal · doi:10.1109/jsen.2010.2046634 · Cited by 146
Sweat Composition in Relation to Rate of Sweating in Patients with Cystic Fibrosis of the Pancreas
Emrich, H. M., Stoll, E., Friolet, B., Colombo, J. P., Richterich, R., & Rossi, E. (1968) · Pediatric Research · doi:10.1203/00006450-196811000-00004 · Cited by 130
Lima, L. F., Vieira, A. L., Mukai, H., Andrade, C. M. G., & Fernandes, P. R. G. (2017) · Journal of Molecular Liquids · doi:10.1016/j.molliq.2017.06.069 · Cited by 74
The non-linear relationship between nerve conduction velocity and skin temperature.
Todnem, K., Knudsen, G. T. M., Riise, T., Nyland, H., & Aarli, J. (1989) · Journal of Neurology Neurosurgery & Psychiatry · doi:10.1136/jnnp.52.4.497 · Cited by 72
Textile sensors to measure sweat pH and sweat-rate during exercise
Coyle, S. M., Morris, D., Lau, K., Diamond, D., Francesco, F. D., Taccini, N., Trivella, M. G., Costanzo, D., Salvo, P., Porchet, J.-A., et al. (2009) · International Conference on Pervasive Computing Technologies for Healthcare · doi:10.4108/icst.pervasivehealth2009.5957 · Cited by 68
Yamamoto, D., Nakata, S., Kanao, K., Arie, T., Akita, S., & Takei, K. (2017) · Advanced Materials Technologies · doi:10.1002/admt.201700057 · Cited by 52
Exercise-Induced Trace Mineral Element Concentration in Regional Versus Whole-Body Wash-Down Sweat
Baker, L. B., Stofan, J. R., Lukaski, H. C., & Horswill, C. A. (2011) · International Journal of Sport Nutrition and Exercise Metabolism · doi:10.1123/ijsnem.21.3.233 · Cited by 35
Nutritional Assessment of Athletes
(2010) · CRC Press eBooks · doi:10.1201/b10203 · Cited by 16
Cited by
Bio-Integrated Wearable Systems: A Comprehensive Review
Ray, T. R., Choi, J., Bandodkar, A. J., Krishnan, S., Gutruf, P., Tian, L., Ghaffari, R., & Rogers, J. A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00573 · Cited by 1,350
End-to-end design of wearable sensors
Ates, H. C., Nguyen, P. Q., Gonzalez-Macia, L., Morales-Narváez, E., Güder, F., Collins, J. J., & Dincer, C. (2022) · Nature Reviews Materials · doi:10.1038/s41578-022-00460-x · Cited by 1,306
A laser-engraved wearable sensor for sensitive detection of uric acid and tyrosine in sweat
Yang, Y., Song, Y., Bo, X., Min, J., Pak, O. S., Zhu, L., Wang, M., Tu, J., Kogan, A., Zhang, H., et al. (2020) · Nature Biotechnology · doi:10.1038/s41587-019-0321-x · Cited by 1,270
Self-citationFlexible Electronics toward Wearable Sensing
Gao, W., Ota, H., Kiriya, D., Takei, K., & Javey, A. (2019) · Accounts of Chemical Research · doi:10.1021/acs.accounts.8b00500 · Cited by 1,265
Self-citationDevice integration of electrochemical biosensors
Wu, J., Liu, H., Chen, W., Ma, B., & Ju, H. (2023) · Nature Reviews Bioengineering · doi:10.1038/s44222-023-00032-w · Cited by 895
Metadata
- Authors
- Nyein, H. Y. Y., Tai, L.-C., Ngo, Q. P., Chao, M., Zhang, G. B., Gao, W., Bariya, M., Bullock, J., Kim, H., Fahad, H. M., & Javey, A.
- Venue
- ACS Sensors
- Publisher
- American Chemical Society (ACS)
- Published
- 2018-05-09
- Volume
- 3
- Issue
- 5
- Pages
- 944-952
- ISSN
- 2379-3694 (ISSN-L)
- OpenAlex
- W2802678962
- Cited by
- 446
- References
- 39
- FWCI
- 14.44
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.