A clock network for geodesy and fundamental science
Open accessThe DOI matches its Crossref record; 47 of the 53 references it cites were found in a registry or an index; 18 of the 22 sources its claims cite were checked for support.
Abstract
Leveraging the unrivalled performance of optical clocks as key tools for geo-science, for astronomy and for fundamental physics beyond the standard model requires comparing the frequency of distant optical clocks faithfully. Here, we report on the comparison and agreement of two strontium optical clocks at an uncertainty of 5 × 10(-17) via a newly established phase-coherent frequency link connecting Paris and Braunschweig using 1,415 km of telecom fibre. The remote comparison is limited only by the instability and uncertainty of the strontium lattice clocks themselves, with negligible contributions from the optical frequency transfer. A fractional precision of 3 × 10(-17) is reached after only 1,000 s averaging time, which is already 10 times better and more than four orders of magnitude faster than any previous long-distance clock comparison. The capability of performing high resolution international clock comparisons paves the way for a redefinition of the unit of time and an all-optical dissemination of the SI-second.
Overview
CoChat Summary
TL;DR
The paper demonstrates a direct all-optical comparison of two independent strontium lattice clocks in Paris and Braunschweig over 1,415 km of telecom fibre, achieving agreement at the 5 × 10−17 level. The fibre link contributes negligibly to the measurement, making the clock performance itself the limiting factor.
Key findings
- Two remote strontium optical clocks were compared with an uncertainty of 5 × 10−17 via a phase-coherent fibre link spanning 1,415 km of telecom fibre.
- A fractional precision of 3 × 10−17 was reached after 1,000 s averaging time, described as 10 times better and more than four orders of magnitude faster than any previous long-distance clock comparison.
- In the more extensive second campaign, the fractional offset between the clocks was (4.7 ± 5.0) × 10−17, with agreement within the combined uncertainties.
- The optical link’s fractional uncertainty was assessed as 2.5 × 10−19, and its instability averaged down faster than the clocks, so the remote comparison was limited by the clocks themselves.
Methods
- Two independent strontium optical lattice clocks were operated at LNE-SYRTE in Paris and PTB in Braunschweig; their frequencies were transferred to Strasbourg through stabilized fibre links and compared using femtosecond frequency combs.
- The study analyzed two measurement campaigns (March and June 2015) with 145 h of accumulated data; frequency ratios were corrected for systematic shifts, gravity-potential/redshift differences, and counter synchronization offsets.
- The main analysis combined local clock-to-transfer-laser comparisons, link-noise-cancelled fibre transfer, and Allan-deviation-based uncertainty evaluation for clock, link, and synchronization contributions.
Limitations
- The paper states that the comparison is limited by the instability and uncertainty of the strontium lattice clocks themselves, not by the optical transfer system.
- During the first campaign, counter gates in Paris and Strasbourg were accidentally not synchronized to UTC, requiring indirect reconstruction of the offset with an uncertainty of 10 ms; this is a stated experimental complication.
- Evident from the text: the results are for two clocks of the same species and under a specific fibre-network configuration, so the paper does not directly test broader clock types or fully general network conditions.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Figures



Verification
Claims the paper makes
8 Valid · 3 Not valid · 2 Not checked · 35 Own results and interpretations
The sources with a verdict support this claim; the rest weren’t checked yet, have no full text we could read, or their verdicts aren’t rated yet.
In the paper
“Our work not only enables the above mentioned applications, but also clears the path towards a redefinition of the unit of time, the SI second2425 through regular and practical international comparisons of optical clocks.”
§ A clock network for geodesy and fundamental science > Abstract
What the sources say
- Supportedcites [24] Riehle, F. Towards a redefinition of the second based on optical atomic clocks. C. R. Physique 16, 506–515 (2015). source
The Abstract (p. 1) identifies ways to compare remote optical clocks among the prerequisites for a future redefinition of the SI second. Section 4 (p. 12) discusses international clock comparisons and practical links for carrying them out. The citing authors’ statement that their own work ‘clears the path’ is their conclusion, not a finding attributed to Riehle. (LLM, conf=0.88)
- Not checked — no full text of the sourcecites [25] Margolis, H. Timekeepers of the future. Nat. Phys. 10, 82–83 (2014). source
boostedstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
Every source the paper cites for this claim was checked and supports it.
In the paper
“satellite link techniques do not reach significantly better performance either.”
§ A clock network for geodesy and fundamental science > Abstract
What the sources say
- Supportedcites [20] Hachisu, H. et al. Direct comparison of optical lattice clocks with an intercontinental baseline of 9000, km. Opt. Lett. 39, 4072–4075 (2014). source
On p. 3, the paper reports a 1.6 × 10⁻¹⁵ uncertainty for its satellite-linked clock comparison and gives 6 × 10⁻¹⁶ for a comparison using local Cs fountain clocks. Its p. 1 discussion also describes the performance limits of the GPSCP and TWCP satellite techniques. These passages support the claim that the satellite links did not deliver substantially better performance than the microwave-clock comparison discussed. (LLM, conf=0.84)
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“Complemented by phase-coherent telecom fibre links9101112 as extremely powerful tools for frequency dissemination on a continental scale”
§ A clock network for geodesy and fundamental science > Abstract
What the sources say
- Not checked — no full text of the sourcecites [9] Predehl, K. et al. A 920-Kilometer optical fiber link for frequency metrology at the 19th decimal place. Science 336, 441–444 (2012). source
- Supportedcites [10] Lopez, O. et al. Ultra-stable long distance optical frequency distribution using the Internet fiber network. Opt. Express 20, 23518–23526 (2012). source
The Introduction (p. 3) describes a phase-stabilized 540 km link on a public telecom network for disseminating ultra-stable optical signals and calls the approach scalable. It also discusses extending frequency distribution to a larger scale, supporting the claim about these links as tools for continental-scale dissemination. (LLM, conf=0.86)
- Partly supportedcites [11] Calosso, C. E. et al. Doppler-stabilized fiber link with 6 dB noise improvement below the classical limit. Opt. Lett. 40, 131–134 (2015). sourceExperimental — accuracy not yet measured
The passage labeled Abstract (p. 2) calls optical fiber links a key tool for frequency dissemination and describes coherent links using standard telecom fiber. But the reported experiment used a 47 km metropolitan link (Abstract, pp. 1, 3); our copy does not establish frequency dissemination on a continental scale. (LLM, conf=0.84)
boosted- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“The details of the actual implementation of state preparation and interrogation being quite different in the two experimental realizations of a Sr lattice clock5212223, systematic and statistical uncertainties are highly independent and uncorrelated.”
§ A clock network for geodesy and fundamental science > Results > Optical clock performance
What the sources say
- Partly supportedcites [5] Le Targat, R. et al. Experimental realization of an optical second with strontium lattice clocks. Nat. Commun. 4, 2109 (2013). sourceExperimental — accuracy not yet measured
The OLC architecture section says the two Sr clocks differ in key features, and the Figure 3 caption treats their combined systematic uncertainty as that of two uncorrelated clocks. Figure 1 describes independent probe feedback, but the paper does not establish that state preparation and interrogation are quite different or explicitly say that the clocks’ statistical uncertainties are uncorrelated. (LLM, conf=0.82)
- Could not verifycites [21] Falke, S. et al. A strontium lattice clock with 3 × 10−17 inaccuracy and its frequency. New J. Phys. 16, 073023 (2014). sourceExperimental — accuracy not yet measured
Section 2 describes the preparation and interrogation of this paper’s Sr clock, and section 5 compares its measured frequency with results from other laboratories. Neither passage describes differences between two Sr-clock implementations or says that their systematic and statistical uncertainties are independent or uncorrelated. Searches for those terms and the claimed comparison found no supporting passage. (LLM, conf=0.76)
- Could not verifycites [22] Grebing, C. et al. Realization of a time-scale with an optical clock. Optica 3, 563–569 (2016). sourceExperimental — accuracy not yet measured
Section II (p. 2) describes one Sr lattice clock operated in two campaigns, and the Supplementary Material (p. 7) describes its preparation and interrogation. The paper does not compare the implementations of two Sr clocks or say that their systematic and statistical uncertainties are uncorrelated; the independence mentioned in Data Analysis (p. 3) concerns two Cs fountain clocks. (LLM, conf=0.76)
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“This international all-optical clock measurement surpasses the accuracy of the best possible comparison achievable by measurements against primary caesium clocks by one order of magnitude5212223.”
§ A clock network for geodesy and fundamental science > Results > Campaigns to compare the strontium optical clocks
What the sources say
- Partly supportedcites [5] Le Targat, R. et al. Experimental realization of an optical second with strontium lattice clocks. Nat. Commun. 4, 2109 (2013). sourceExperimental — accuracy not yet measured
The Discussion (page unavailable) reports that a direct comparison of two strontium optical clocks achieved agreement better than three of the best caesium fountains could resolve. But the reported optical comparison uncertainty was 1.5 × 10⁻¹⁶ versus 3.1 × 10⁻¹⁶ for the caesium-based comparison—not an order of magnitude—and the Discussion describes comparisons between clocks at different institutes as future work, not this measurement. (LLM, conf=0.88)
- Partly supportedcites [21] Falke, S. et al. A strontium lattice clock with 3 × 10−17 inaccuracy and its frequency. New J. Phys. 16, 073023 (2014). sourceExperimental — accuracy not yet measured
The Introduction (page not available) says the best caesium fountain clocks limit absolute frequency measurements to about 2–4 × 10⁻¹⁶. Results and discussion (page not available) says direct optical-clock comparisons achieve smaller relative uncertainties, but does not quantify a tenfold advantage for an international all-optical measurement. This paper’s own absolute measurement used caesium fountains, so its nearly tenfold advantage refers to the strontium clock’s systematic uncertainty, not that measurement’s accuracy. (LLM, conf=0.85)
- Partly supportedcites [22] Grebing, C. et al. Realization of a time-scale with an optical clock. Optica 3, 563–569 (2016). sourceExperimental — accuracy not yet measured
Optical Clock Operation (p. 2) says the strontium clock’s systematic uncertainty is at least an order of magnitude below that of PTB’s primary caesium fountains. But this paper’s measurement compares a local strontium clock with caesium fountains; Data Analysis (p. 4) discusses agreement with measurements at other institutes, not the accuracy of the cited international all-optical measurement. (LLM, conf=0.86)
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
28 more claims · 1 with their cited sources checked
Create a free account to see all 48 claims and every source verdict.
- It may state two separate claims as one. 12
- Probably not a substantial claim. 3
- The quote only partly states this claim. 1
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Furthermore, the frequency of two atomic clocks can be compared via an interferometric fiber link (IFL), which supports sub-10 -19 accuracy over hundreds of kilometers [5-10].”
From Long-distance chronometric leveling with a portable optical clock (2024) · cites this paper as [6]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Phase compensated optical fiber links enable high accuracy atomic clocks separated by thousands of kilometers to be compared with unprecedented statistical resolution.”
From Test of Special Relativity Using a Fiber Network of Optical Clocks (2017) · cites this paper as [9]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“They reached the accuracy of 3×10 -17 using two Sr-lattice clocks with an uncertainty of 5×10 -17 between Paris and Braunschweig stations.”
From Time transfer and significance of vertical land motion in relativistic geodesy applications: a review paper (2023) · cites this paper as Lisdat et al. (2016)
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“A first attempt in this direction was the comparison of two strontium optical clocks between PTB and OBSPARIS via a fibre link, showing an uncertainty and agreement with the geodetic results of about 5 × 10 -17 (Lisdat et al. 2016).”
From Geodetic methods to determine the relativistic redshift at the level of 10 $$^{-18}$$ - 18 in the context of international timescales: a review and practical results (2018) · cites this paper as Lisdat et al. 2016
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Therefore, phase-coherent optical links have been developped using principally an optical fibre as a medium for the propagation [108, 109, 75, 74], attaining spectacular stability and accuracy in the range 10 -19 and below.”
From Chronometric Geodesy: Methods and Applications (2019) · cites this paper as [75]
Experimental — accuracy not yet measured
8 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Frequency Ratio of Al+and Hg+Single-Ion Optical Clocks; Metrology at the 17th Decimal Place
Rosenband, T., Hume, D. B., Schmidt, P. O., Chou, C. W., Brusch, A., Lorini, L., Oskay, W. H., Drullinger, R. E., Fortier, T. M., Stalnaker, J. E., et al. (2008) · Science · doi:10.1126/science.1154622 · Cited by 1,450
An optical lattice clock with accuracy and stability at the 10−18 level
Bloom, B. J., Nicholson, T. L., Williams, J. R., Campbell, S. L., Bishof, M., Zhang, X., Zhang, W., Bromley, S. L., & Ye, J. (2014) · Nature · doi:10.1038/nature12941 · Cited by 1,073
Nobel Lecture: Passion for precision
Hänsch, T. W. (2006) · Reviews of Modern Physics · doi:10.1103/revmodphys.78.1297 · Cited by 915
Frequency Comparison of Two High-Accuracy Al + Optical Clocks
Chou, C., Hume, D., Koelemeij, J., Wineland, D., & Rosenband, T. (2010) · Physical Review Letters · doi:10.1103/physrevlett.104.070802 · Cited by 903
Chou, C. W., Hume, D. B., Rosenband, T., & Wineland, D. J. (2010) · Science · doi:10.1126/science.1192720 · Cited by 828
An Atomic Clock with 10 –18 Instability
Hinkley, N., Sherman, J. A., Phillips, N. B., Schioppo, M., Lemke, N. D., Beloy, K., Pizzocaro, M., Oates, C. W., & Ludlow, A. D. (2013) · Science · doi:10.1126/science.1240420 · Cited by 817 · cited 1×
“Optical clocks are – due to their orders of magnitude better precision (1) and accuracy (2,3,4) than their microwave counterparts realizing the definition of the SI second – new sensors with highest resolving power to, e.”
BackgroundSystematic evaluation of an atomic clock at 2 × 10−18 total uncertainty
Nicholson, T. L., Campbell, S. L., Hutson, R. B., Marti, G. E., Bloom, B. J., McNally, R. L., Zhang, W., Barrett, M. D., Safronova, M. S., Strouse, G. F., et al. (2015) · Nature Communications · doi:10.1038/ncomms7896 · Cited by 780 · cited 1×
“Optical clocks are – due to their orders of magnitude better precision (1) and accuracy (2,3,4) than their microwave counterparts realizing the definition of the SI second – new sensors with highest resolving power to, e.”
BackgroundKómár, P., Kessler, E. M., Bishof, M., Jiang, L., Sørensen, A. S., Ye, J., & Lukin, M. D. (2014) · Nature Physics · doi:10.1038/nphys3000 · Cited by 768 · cited 1×
“Additionally, new geodetic reference frames based on relativistic geodesy (15,16) or a quantum network of clocks (17) can be established.”
BackgroundCryogenic optical lattice clocks
Ushijima, I., Takamoto, M., Das, M., Ohkubo, T., & Katori, H. (2015) · Nature Photonics · doi:10.1038/nphoton.2015.5 · Cited by 627 · cited 1×
“Optical clocks are – due to their orders of magnitude better precision (1) and accuracy (2,3,4) than their microwave counterparts realizing the definition of the SI second – new sensors with highest resolving power to, e.”
BackgroundNobel Lecture: Defining and measuring optical frequencies
Hall, J. L. (2006) · Reviews of Modern Physics · doi:10.1103/revmodphys.78.1279 · Cited by 614
Research works printed but not linked: 1
- Vermeer, M. Chronometric levelling, Reports of the Finnish Geodetic Institute 83, 2 (1983).
Cited by
Items 101–200 of 455
Low-loss reciprocal optical terminals for two-way time-frequency transfer
Swann, W. C., Sinclair, L. C., Khader, I. H., Bergeron, H., Deschênes, J.-D., & Newbury, N. R. (2017) · Applied Optics · doi:10.1364/ao.56.009406 · Cited by 30
Measuring absolute frequencies beyond the GPS limit via long-haul optical frequency dissemination
Clivati, C., Cappellini, G., Livi, L. F., Poggiali, F., de Cumis, M. S., Mancini, M., Pagano, G., Frittelli, M., Mura, A., Costanzo, G. A., et al. (2016) · PORTO Publications Open Repository TOrino (Politecnico di Torino) · Cited by 29
Optical atomic clock comparison through turbulent air
Bodine, M. I., Deschênes, J.-D., Khader, I. H., Swann, W. C., Leopardi, H., Beloy, K., Bothwell, T., Brewer, S. M., Bromley, S., Chen, J.-S., et al. (2020) · Physical Review Research · doi:10.1103/physrevresearch.2.033395 · Cited by 30
“[31] C.”
BackgroundSelf-citationHigh-Precision Time-Frequency Signal Simultaneous Transfer System via a WDM-Based Fiber Link
Zang, Q., Quan, H., Zhao, K., Zhang, X., Deng, X., Xue, W., Chen, F., Liu, T., Dong, R., & Zhang, S. (2021) · Photonics · doi:10.3390/photonics8080325 · Cited by 29
Robust optical clock transitions in trapped ions using dynamical decoupling
Aharon, N., Spethmann, N., Leroux, I. D., Schmidt, P. O., & Retzker, A. (2019) · New Journal of Physics · doi:10.1088/1367-2630/ab3871 · Cited by 34
Endo, M., & Schibli, T. R. (2018) · OSA Continuum · doi:10.1364/osac.1.000116 · Cited by 30
Enhanced Carrier to Noise Ratio by Brillouin Amplification for Optical Communications
Pelusi, M. D., Inoue, T., & Namiki, S. (2019) · Journal of Lightwave Technology · doi:10.1109/jlt.2019.2948226 · Cited by 27
“On the other hand, the unique narrow gain bandwidth is advantageous for more specialized applications including optical clock frequency transfer [3]–[5],”
BackgroundChronometric Geodesy: Methods and Applications
Delva, P., Denker, H., & Lion, G. (2019) · Fundamental Theories of Physics · doi:10.1007/978-3-030-11500-5_2 · Cited by 28
“racy and stability in the 10 17{10 19 range [104, 105, 76, 77, 106, 107]. Therefore, phase-coherent optical links have been developped using principally an optical bre as a medium for the propagation [108, 109, 75, 74], attaining spectacular stability and accuracy in the range 10 19 and below. However, phase coherent…”
BackgroundMethodSelf-citationFiber-optic joint time and frequency transmission with enhanced time precision
Zuo, F., Li, Q., Xie, K., et al. (2022) · Optics Letters · doi:10.1364/ol.450696 · Cited by 26
Wang, L., Liu, Y., Jiao, W., Hu, L., Chen, J., & Wu, G. (2022) · Optics Express · doi:10.1364/oe.462808 · Cited by 27
A way forward for fundamental physics in space
Bassi, A., Cacciapuoti, L., Capozzıello, S., Dell’Agnello, S., Diamanti, E., Giulini, D., IESS, L., Jetzer, P., Joshi, S. K., Landragin, A., et al. (2022) · npj Microgravity · doi:10.1038/s41526-022-00229-0 · Cited by 39
Schreiber, U. K., & Kodet, J. (2017) · Space Science Reviews · doi:10.1007/s11214-017-0457-2 · Cited by 26
Coherent fibre link for synchronization of delocalized atomic clocks
Cizek, M., Pravdova, L., Pham, T. M., Lesundak, A., Hrabina, J., Lazar, J., Pronebner, T., Aeikens, E., Premper, J., Havliš, O., et al. (2022) · Optics Express · doi:10.1364/oe.447498 · Cited by 27
Reduction of light shifts in Ramsey spectroscopy with a combined error signal
Shuker, M., Pollock, J. W., Boudot, R., Yudin, V. I., Taichenachev, A. V., Kitching, J., & Donley, E. A. (2019) · Applied Physics Letters · doi:10.1063/1.5093921 · Cited by 30
Using quantum optical sensors for determining the Earth’s gravity field from space
Müller, J., & Wu, H. (2020) · Journal of Geodesy · doi:10.1007/s00190-020-01401-8 · Cited by 32
Quadrupole Shift Cancellation Using Dynamic Decoupling
Shaniv, R., Akerman, N., Manovitz, T., Shapira, Y., & Ozeri, R. (2019) · Physical Review Letters · doi:10.1103/physrevlett.122.223204 · Cited by 31
“[5] Christian Lisdat, G Grosche, N Quintin, C Shi, SMF Raupach, C Grebing, D Nicolodi, Fabio Stefani, A Al-Masoudi, S Dörscher, et al.”
BackgroundLong-Haul High Precision Frequency Dissemination Based on Dispersion Correction
Chen, Y., Dai, H., Si, H., Wang, F., Wang, B., & Wang, L. (2022) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2022.3214617 · Cited by 27
“In the fields of radio telescope array [1], [2], [3], [4], time and frequency synchronization network [5], [6], real-time comparison of remote atomic clocks and their coordination [7], [8], [9], geodesy and fundamental science [10], [11], frequency dissemination spanning hundreds of kilometers fiber link will play a v…”
BackgroundShen, Z., Shen, W., Zhao, P., Liu, T., Zhang, S., & Chao, D. (2019) · Journal of Earth Science · doi:10.1007/s12583-018-0834-0 · Cited by 24
Ultralight Dark Matter Search with Space-Time Separated Atomic Clocks and Cavities
Filzinger, M., Caddell, A. R., Jani, D., Steinel, M., Giani, L., Huntemann, N., & Roberts, B. M. (2025) · Physical Review Letters · doi:10.1103/physrevlett.134.031001 · Cited by 45
“The fibre links allow state-of-the-art comparisons of optical frequencies over ∼ 10 3 km distances with ≲ 10 − 17 precision [34, 55].”
BackgroundAb initio quantum theory of mass defect and time dilation in trapped-ion optical clocks
Martínez-Lahuerta, V. J., Eilers, S., Mehlstäubler, T. E., Schmidt, P. O., & Hammerer, K. (2022) · Physical Review A · doi:10.1103/physreva.106.032803 · Cited by 30
Time and laser ranging: a window of opportunity for geodesy, navigation, and metrology
Exertier, P., Belli, A., Samain, É., Meng, W., Zhang, H., Tang, K., Schlicht, A., Schreiber, U. K., Hugentobler, U., Procházka, I., et al. (2018) · Journal of Geodesy · doi:10.1007/s00190-018-1173-8 · Cited by 25
20 Years and 20 Decimal Digits: A Journey With Optical Frequency Combs
Giunta, M., Fischer, M., Hänsel, W., Steinmetz, T., Lessing, M., Holzberger, S., Cleff, C., Hänsch, T. W., Mei, M., & Holzwarth, R. (2019) · IEEE Photonics Technology Letters · doi:10.1109/lpt.2019.2955096 · Cited by 24
“now reaching residual instabilities comparable to the one reached on fiber links [42].”
BackgroundIkeda, K., Okubo, S., Wada, M., Kashiwagi, K., Yoshii, K., Inaba, H., & Hong, F.-L. (2020) · Optics Express · doi:10.1364/oe.381961 · Cited by 28
Observation of an Inner-Shell Orbital Clock Transition in Neutral Ytterbium Atoms
Ishiyama, T., Ono, K., Takano, T., Sunaga, A., & Takahashi, Y. (2023) · Physical Review Letters · doi:10.1103/physrevlett.130.153402 · Cited by 32
Dual-comb-enhanced microwave clock synchronization over commercial fiber
Chen, Z., Yu, D., Lu, G., Zhang, Y., Yu, S., Luo, B., & Guo, H. M. (2024) · Optica · doi:10.1364/optica.530224 · Cited by 28
Time and frequency transfer over a 500 km cascaded White Rabbit network
Kaur, N., Frank, F., Pottie, P.-É., & Tuckey, P. A. (2017) · Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS) · doi:10.1109/fcs.2017.8088808 · Cited by 25
“Currently, the most accurate way of comparing remotely located atomic clocks is by the means of optical frequency transfer by coherent fiber links [2].”
BackgroundSelf-citationA Sub-ps Stability Time Transfer Method Based on Optical Modems
Frank, F., Stefani, F., Tuckey, P. A., & Pottie, P.-É. (2018) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2018.2833389 · Cited by 21
Self-citationA 500-km Cascaded White Rabbit Link for High-Performance Frequency Dissemination
Kaur, N., Frank, F., Pinto, J., Tuckey, P. A., & Pottie, P.-É. (2021) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2021.3134163 · Cited by 27
Self-citationLu, X., Guo, F., Wang, Y., Xu, Q., Zhou, C., Xia, J., Wu, W., & Chang, H. (2023) · Metrologia · doi:10.1088/1681-7575/acb05c · Cited by 24
Stability Limitations of Optical Frequency Transfer in Telecommunication DWDM Networks
Turza, K., Krehlik, P., & Śliwczyński, Ł. (2019) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2019.2957176 · Cited by 23
“spectroscopy [13]–[15], or geodesy and fundamental science [16].”
BackgroundTian, X., Hu, L., Wu, G., & Chen, J. (2020) · Journal of Lightwave Technology · doi:10.1109/jlt.2020.2989328 · Cited by 23
“isons [4], [5] and tests of fundamental physics [6], [7].”
BackgroundNon-reciprocity in optical fiber links: experimental evidence
Xu, D., Lopez, O., Amy‐Klein, A., & Pottie, P.-É. (2021) · Optics Express · doi:10.1364/oe.420661 · Cited by 25
Self-citationHigh-precision optical time and frequency transfer
Caldwell, E. D., Triano, T., & Sinclair, L. C. (2025) · Advances in Optics and Photonics · doi:10.1364/aop.545290 · Cited by 36
Time–frequency transfer over optical fiber
Chen, Z., Zhang, Y., Luo, B., & Guo, H. M. (2025) · National Science Review · doi:10.1093/nsr/nwaf236 · Cited by 24
Wu, L., Jiang, Y., Ma, C., Yu, H., Bi, Z., & Ma, L.-S. (2016) · Optics Letters · doi:10.1364/ol.41.004368 · Cited by 19
A re-evaluation of the relativistic redshift on frequency standards at NIST, Boulder, Colorado, USA
Pavlis, N. K., & Weiss, M. A. (2017) · Metrologia · doi:10.1088/1681-7575/aa765c · Cited by 25
“We note that in an experiment reported in August 2016 [37], describing the Metrologia 54 (2017) 535”
MethodUrban Fiber Based Laser Interferometry for Traffic Monitoring and Analysis
Wang, G., Pang, Z., Wang, F., Chen, Y., Dai, H., & Wang, B. (2022) · Journal of Lightwave Technology · doi:10.1109/jlt.2022.3209499 · Cited by 24
“use of fiber in more and more areas [1], [2], [3], [4], [5], [6], [7], [8], [9], [10].”
BackgroundFemtosecond Timekeeping: Slip-Free Clockwork for Optical Timescales
Herman, D. I., Droste, S., Baumann, E., Roslund, J., Churin, D., Cingöz, A., Deschênes, J.-D., Khader, I. H., Swann, W. C., Nelson, C. W., et al. (2018) · Physical Review Applied · doi:10.1103/physrevapplied.9.044002 · Cited by 21
Towards an International Height Reference Frame Using Clock Networks
Wu, H., & Müller, J. (2020) · International Association of Geodesy symposia · doi:10.1007/1345_2020_97 · Cited by 19
On-line estimation of local oscillator noise and optimisation of servo parameters in atomic clocks
Leroux, I. D., Scharnhorst, N., Hannig, S., Kramer, J., Pelzer, L., Stepanova, M., & Schmidt, P. O. (2017) · Institutional Repository of Leibniz Universität Hannover (Leibniz Universität Hannover) · doi:10.15488/1728 · Cited by 18
Atmospheric refraction corrections in ground-to-satellite optical time transfer
Stuhl, B. (2021) · Optics Express · doi:10.1364/oe.421620 · Cited by 20
A universal, plug-and-play synchronisation scheme for practical quantum networks
D’Auria, V., Fedrici, B., Ngah, L. A., Kaiser, F., Labonté, L., Alibart, O., & Tanzilli, S. (2020) · npj Quantum Information · doi:10.1038/s41534-020-0245-9 · Cited by 22
Coordinated international comparisons between optical clocks connected via fiber and satellite links
Lindvall, T., Pizzocaro, M., Godun, R. M., Abgrall, M., Akamatsu, D., Amy‐Klein, A., Benkler, E., Bhatt, N., Calonico, D., Cantin, E., et al. (2025) · Optica · doi:10.1364/optica.561754 · Cited by 37
“…do not introduce any appreciable uncertainty into the measurements should be chosen and so, where possible, the clocks were compared either locally (at NPL and PTB) or else connected via international optical fibers that have been shown to support comparisons at the 10 − 18 level and below [22–25].”
Self-citationOptical atomic clocks: defining the future of time and frequency metrology
Fortier, T. M., Luiten, A. N., & Margolis, H. S. (2025) · Optica · doi:10.1364/optica.575770 · Cited by 43
Zuo, F., Chen, Z., Hu, L., Chen, J., Jin, Y., & Wu, G. (2020) · Journal of Lightwave Technology · doi:10.1109/jlt.2020.3043340 · Cited by 20
Zhang, P., Zhang, Y., Li, M., Rao, B., Yan, L., Chen, F., Zhang, X.-F., Chen, Q., Jiang, H., & Zhang, S. (2021) · Chinese Physics B · doi:10.1088/1674-1056/ac40f6 · Cited by 19
Yu, D., Chen, Z., Zhang, Y., Jin, Z., Yu, S., Luo, B., & Guo, H. M. (2024) · Physical Review Research · doi:10.1103/physrevresearch.6.023005 · Cited by 20
Time transfer over a White Rabbit network
Kaur, N., Tuckey, P. A., & Pottie, P.-É. (2016) · European Frequency and Time Forum · doi:10.1109/eftf.2016.7477793 · Cited by 18
Self-citationSub-Hertz frequency stabilization of 1. 55 μ m laser on Higher order HG mn mode
Jiao, D., Gao, J., Deng, X., Xu, G., Liu, J., Liu, T., Dong, R., & Zhang, S. (2020) · Optics Communications · doi:10.1016/j.optcom.2020.125460 · Cited by 20
Improved frequency ratio measurement with 87 Sr and 171 Yb optical lattice clocks at NMIJ
Hisai, Y., Akamatsu, D., Kobayashi, T., Hosaka, K., Inaba, H., Hong, F.-L., & Yasuda, M. (2020) · Metrologia · doi:10.1088/1681-7575/abc104 · Cited by 17
“Longdistance fibre links that allow us to compare optical clocks have been demonstrated [11].”
Branching Optical Frequency Transfer With Enhanced Post Automatic Phase Noise Cancellation
Xue, R., Hu, L., Shen, J., Chen, J., & Wu, G. (2021) · Journal of Lightwave Technology · doi:10.1109/jlt.2021.3076182 · Cited by 18
“This optical-frequency transfer capability was developed for optical clock comparison and timekeeping [9], [10], [11], [12], [13].”
BackgroundIncubating advances in integrated photonics with emerging sensing and computational capabilities
Jain, S., Hlaing, M. H., Fan, K.-C., Midkiff, J., Ning, S., Feng, C., Hsiao, P.-Y., Camp, P. T., & Chen, R. T. (2025) · Applied Physics Reviews · doi:10.1063/5.0218564 · Cited by 21
Intensity interferometry for ultralight bosonic dark matter detection
Masia‐Roig, H., Figueroa, N. L., Bordon, A., Smiga, J. A., Stadnik, Y. V., Budker, D., Centers, G. P., Gramolin, A. V., Hamilton, P., Khamis, S., et al. (2023) · Physical review. D/Physical review. D. · doi:10.1103/physrevd.108.015003 · Cited by 26
“[105] Christian Lisdat, G Grosche, N Quintin, C Shi, SMF Raupach, C Grebing, D Nicolodi, F Stefani, A AlMasoudi, S Dörscher, et al.”
BackgroundInfluentialMulti-node optical frequency dissemination with post automatic phase correction
Hu, L., Tian, X., Wu, G., Kong, M., Shen, J., & Chen, J. (2020) · Journal of Lightwave Technology · doi:10.1109/jlt.2020.2976167 · Cited by 24
“To date, efforts have mainly focused on long-distance connections between just two locations connected by an optical fiber by correcting phase perturbations between the local and remote end [8], For example, frequency comparison between two separated Sr optical clocks located at PTB (Germany) and SYRTE (France) has be…”
BackgroundRobust optical frequency dissemination with a dual-polarization coherent receiver
Clivati, C., Savio, P., Abrate, S., Curri, V., Gaudino, R., Pizzocaro, M., & Calonico, D. (2020) · Optics Express · doi:10.1364/oe.378602 · Cited by 19
Two-Branch Fiber Link for International Clock Networks
Xu, D., Cantin, E., Frank, F., Quintin, N., Meynadier, F., Tuckey, P. A., Amy‐Klein, A., Lopez, O., & Pottie, P.-É. (2019) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2018.2886865 · Cited by 16
“1 is a four-span cascaded link of 2×705 km from SYRTE to the University of Strasbourg and back [1], [10].”
BackgroundMethodInfluentialSelf-citationGeneralized Ramsey methods in the spectroscopy of coherent-population-trapping resonances
Basalaev, M. Y., Yudin, V. I., Коваленко, Д. В., Zanon-Willette, T., & Тайченачев, А. В. (2020) · Physical Review A · doi:10.1103/physreva.102.013511 · Cited by 15
Reciprocity of propagation in optical fiber links demonstrated to 10−21
Xu, D., Delva, P., Lopez, O., Amy-Klein, A., & Pottie, P.-E. (2019) · Optics Express · doi:10.1364/oe.27.036965 · Cited by 15
Self-citationWDM-Based Fiber-Optic Time Synchronization Without Requiring Link Calibration
Zuo, F., Chen, Z., Hu, L., Chen, J., & Wu, G. (2020) · IEEE Access · doi:10.1109/access.2020.3003702 · Cited by 15
Hu, L., Xue, R., Cao, X., Liu, J., Wu, K., Wu, G., & Chen, J. (2022) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2022.3191656 · Cited by 14
“Overall, the system performance in terms of the phase noise PSDs, fractional frequency instabilities and uncertainty results are all suitable for the optical frequency transfer application for the state-of-the-art optical atomic clocks [1], [2], [3], [4], [5].”
BackgroundCorrelation measurement of co-located hydrogen masers
Guo, Y., Wang, B., W, H., Cai, Z., Zhang, A., Zhu, X., Yang, J., Feng, K. M., Han, C., Li, T. C., et al. (2018) · Metrologia · doi:10.1088/1681-7575/aad146 · Cited by 14
Methods for coherent optical Doppler orbitography
Dix-Matthews, B. P., Schediwy, S., Gozzard, D. R., Driver, S. P., Schreiber, U. K., Carman, R., & Tobar, M. E. (2020) · Journal of Geodesy · doi:10.1007/s00190-020-01380-w · Cited by 15
“This is extremely useful information in fields such as coherent optical communications (Khalighi and Uysal, 2014), and ground-space atomic clock comparisons (Riehle, 2017; Lisdat et al, 2016).”
BackgroundCoherent Optical Frequency Transfer via a 490 km Noisy Fiber Link
Zhang, X., Deng, X., Zang, Q., Jiao, D., Gao, J., Wang, D., Zhou, Q., Liu, J., Xu, G., Dong, R., et al. (2022) · Chinese Physics Letters · doi:10.1088/0256-307x/39/4/044201 · Cited by 14
Phase Noise and Frequency Stability of the Red-Pitaya Internal PLL
Cardenas-Olaya, A., Calosso, C. E., Friedt, J., Micalizio, S., & Rubiola, E. (2018) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2018.2883830 · Cited by 16
“oscillator is generally necessary to achieve the high-frequency resolution required in metrology applications [15]–[18].”
BackgroundMiyashita, T., Kondo, T., Ikeda, K., et al. (2021) · Japanese Journal of Applied Physics · doi:10.35848/1347-4065/ac2e67 · Cited by 13
Coherent fiber links operated for years: effect of missing data
Tønnes, M., Schüller, F., Cantin, E., Lopez, O., Targat, R. L., Amy‐Klein, A., & Pottie, P.-É. (2022) · Metrologia · doi:10.1088/1681-7575/ac938e · Cited by 14
“Coherent optical fiber links have shown great promise, allowing the comparison of optical clocks on a continental scale [10].”
BackgroundSelf-citationTime Reversal Enabled Fiber-Optic Time Synchronization
Chen, Y., Dai, H., Li, W., Wang, F., Wang, B., & Wang, L. (2023) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2023.3300428 · Cited by 20
“In addition, FOTS has been widely used in other fields such as deep-space communication and tracking [12], geodesy [14], [15], navigation, as well as telecommunication [16].”
MethodSimple Stabilized Radio-Frequency Transfer With Optical Phase Actuation
Gozzard, D. R., Schediwy, S., Courtney-Barrer, B., Whitaker, R., & Grainge, K. (2017) · IEEE Photonics Technology Letters · doi:10.1109/lpt.2017.2785363 · Cited by 17
“F IBER-optic frequency transfer networks, such as the European NEAT-FT [1]–[3] and the Beijing regional time and frequency network [4], [5], are now being rolled-out on national and international scales, driven by cutting-edge research in metrology and other physical sciences including the distant comparison of optica…”
BackgroundSimultaneous Transfer of Stabilized Optical and Microwave Frequencies Over Fiber
Gozzard, D. R., Schediwy, S., & Grainge, K. (2017) · IEEE Photonics Technology Letters · doi:10.1109/lpt.2017.2776243 · Cited by 16
“The NEAT-FT network and other high-precision frequency comparison experiments [6], [9], [10], have employed stabilized optical frequency transfer because of the superior fractional frequency stability of optical-frequency signals over radio-frequency (RF) and microwave (MW) signals [5], [11].”
BackgroundInfluentialRecent Advances Concerning the 87Sr Optical Lattice Clock at the National Time Service Center
Wang, Y., Lu, X., Lu, B., Kong, D., & Chang, H. (2018) · Applied Sciences · doi:10.3390/app8112194 · Cited by 14
Optical frequency divider: Capable of measuring optical frequency ratio in 22 digits
Shi, H., Jiang, Y., Yao, Y., Li, B., Wang, C., Yu, H., & Ma, L. (2023) · APL Photonics · doi:10.1063/5.0165602 · Cited by 14
GHZ protocols enhance frequency metrology despite spontaneous decay
Kielinski, T., Schmidt, P. O., & Hammerer, K. (2024) · Science Advances · doi:10.1126/sciadv.adr1439 · Cited by 33
“This unprecedented performance opens the path towards new applications in fundamental research and technology, such as the redefinition of the SI second [1], relativistic geodesy [16–19], tests of general relativity [14, 20–24] and the search for physics beyond the standard model [25–27].”
Highly vibration-resistant sub-Hertz ultra-stable laser passing over 1700 km transport test
Jiao, D., Deng, X., Gao, J., Zhang, L., Xu, G., Liu, T., Dong, R., & Zhang, S. (2023) · Infrared Physics & Technology · doi:10.1016/j.infrared.2023.104608 · Cited by 15
Kudeyarov, K. S., Vishnyakova, G. A., Khabarova, K. Y., & Kolachevsky, N. (2018) · Laser Physics · doi:10.1088/1555-6611/aacfa1 · Cited by 13
Shen, W., Sun, X. L., Cai, C., Wu, K., & Shen, Z. (2019) · Terrestrial Atmospheric and Oceanic Sciences · doi:10.3319/tao.2018.07.09.02 · Cited by 15
“Later Lisdat et al. (2016) and Grotti et al. (2018) successively provided relevant experimental results which confirmed the OFFT approach (Shen and Peng 2012; Shen 2013a, b; Shen et al. 2018b).”
ResultBrillouin Amplifier Noise Characterization by a Coherent Receiver and Digital Signal Processing
Pelusi, M. D., Inoue, T., & Namiki, S. (2020) · Journal of Lightwave Technology · doi:10.1109/jlt.2020.2987644 · Cited by 12
“frequency transfer, [1]–[3], high resolution spectroscopy [4], [5], frequency comb line extraction [5]–[7], and microwave photonic broadband RF phase shifters [8] and synthesized custom gain”
BackgroundYuan, Y., Cui, K., Liu, D., Yuan, J., Cao, J. Z., Wang, D., Chao, S., Shu, H., & Huang, X.-R. (2024) · Physical Review Applied · doi:10.1103/physrevapplied.21.044052 · Cited by 13
“However, numerous other applications require two or more optical clocks to establish a network, facilitating the desired observation by comparing frequency difference between each clock[12–16].”
BackgroundThe impact of femtosecond fiber lasers in technology and science
Fermann, M. E., & Rolland, A. (2024) · Optics Communications · doi:10.1016/j.optcom.2024.131197 · Cited by 14
Absolute phase synchronization over optical fiber
Si, H., Wang, B., Wang, F., Chen, Y., & Wang, L. (2020) · Optics Express · doi:10.1364/oe.387166 · Cited by 11
Digital Doppler-Cancellation Servo for Ultrastable Optical Frequency Dissemination Over Fiber
Mukherjee, S., Millo, J., Marechal, B., Denis, S., Goavec-Merou, G., Friedt, J., Kersalé, Y., & Lacroûte, C. (2021) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2021.3125066 · Cited by 16
“Several proposals have argued for the development of ultra-stable optical fiber networks on the continental scale [19], [20].”
BackgroundInhomogeneous light shifts of coherent population trapping resonances
Pollock, J. W., Yudin, V. I., Тайченачев, А. В., Basalaev, M. Y., Коваленко, Д. В., Hansen, A., Kitching, J. E., & McGehee, W. (2022) · Applied Physics Letters · doi:10.1063/5.0087391 · Cited by 12
Adaptive optics LEO uplink pre-compensation with finite spatial modes
Walsh, S. M., & Schediwy, S. (2023) · Optics Letters · doi:10.1364/ol.482550 · Cited by 14
Fully digital platform for local ultra-stable optical frequency distribution
Matusko, M., Rýger, I., Goavec-Merou, G., Millo, J., Lacroûte, C., Carry, É., Friedt, J., & Delehaye, M. (2023) · Review of Scientific Instruments · doi:10.1063/5.0138599 · Cited by 14
“Long-distance fiber networks now connect many European laboratories using dedicated infrastructures 17,19 .”
BackgroundJones, A. W., Cabrita, R., Korobko, M., van Beuzekom, M., Brown, D., Fafone, V., van Heijningen, J. V., Rocchi, A., Schiworski, M. G., & Tacca, M. (2023) · Optica · doi:10.1364/optica.511924 · Cited by 17
“In addition, we anticipate the routine use of integrated quantum photonics to produce vast entangled networks [156], imaging below the shot noise level (e.g. [157]) and define SI units [158].”
BackgroundSynchronous multi-color laser network with daily sub-femtosecond timing drift
Şafak, K., Xin, M., Peng, M. Y., & Käertner, F. X. (2018) · Scientific Reports · doi:10.1038/s41598-018-30348-2 · Cited by 14
8th Symposium on Frequency Standards and Metrology 2015
Riehle, F. (2016) · Journal of Physics Conference Series · doi:10.1088/1742-6596/723/1/011001 · Cited by 15
“Novel methods that can achieve this goal better use transportable frequency standards [16], the evaluation of direct frequency ratios between optical frequency standards [17, 18], or long haul fiber links for remote frequency comparisons that have been implemented [19].”
Laboratory demonstration of geopotential measurement using transportable optical clocks
Liu, D.-X., Cao, J., Yuan, J.-B., Cui, K.-F., Yuan, Y., Zhang, P., Chao, S.-J., Shu, H.-L., & Huang, X.-R. (2023) · Chinese Physics B · doi:10.1088/1674-1056/ac6337 · Cited by 10
Cai, C., Shen, W., Shen, Z., & Xu, W. S. (2020) · IEEE Access · doi:10.1109/access.2020.3036988 · Cited by 12
“Alternative approaches of determining the geopotential difference using clocks require connecting two clocks with optical fiber/coaxial cables or satellites to transmit frequency signals or time signals between two stations [9]–[13].”
BackgroundPerformance of digital servos in an optical frequency transfer network
Hu, L., Xue, R., Wu, G., & Chen, J. (2021) · Review of Scientific Instruments · doi:10.1063/5.0045168 · Cited by 10
Validating frequency transfer via interferometric fiber links for optical clock comparisons
Koke, S., Benkler, E., Kühl, A., & Grosche, G. (2021) · New Journal of Physics · doi:10.1088/1367-2630/ac21a0 · Cited by 11
Self-citationImproving Short-Term Stability in Optical Lattice Clocks by Quantum Nondemolition Measurement
Orenes, D. B., Sewell, R. J., Lodewyck, J., & Mitchell, M. W. (2022) · Physical Review Letters · doi:10.1103/physrevlett.128.153201 · Cited by 16
Self-citationDigital electronics based on red pitaya platform for coherent fiber links
Cardenas-Olaya, A., Micalizio, S., Ortolano, M., Calosso, C. E., Rubiola, E., & Friedt, J. (2016) · European Frequency and Time Forum · doi:10.1109/eftf.2016.7477826 · Cited by 15
Progress on the REFIMEVE+ project for optical frequency standard dissemination
Cantin, E., Quintin, N., Wiotte, F., Chardonnet, C., Amy‐Klein, A., Lopez, O., Pottie, P.-É., Santarelli, G., & Camisard, É. (2017) · Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS) · doi:10.1109/fcs.2017.8088897 · Cited by 11
Self-citationLiu, H., Jiang, K., Wang, J., Xiong, Z.-X., He, L., & Lü, B. (2018) · Chinese Physics B · doi:10.1088/1674-1056/27/5/053201 · Cited by 11
Relativistic geoid: Gravity potential and relativistic effects
Philipp, D., Hackmann, E., Lämmerzahl, C., & Müller, J. (2020) · Physical review. D/Physical review. D. · doi:10.1103/physrevd.101.064032 · Cited by 16
“[4, 5, 34–39].”
Universal formalism for data sharing and processing in clock comparison networks
Lodewyck, J., Targat, R. L., Pottie, P.-É., Benkler, E., Koke, S., & Kronjäger, J. (2020) · Physical Review Research · doi:10.1103/physrevresearch.2.043269 · Cited by 13
Self-citationPolarization Scramblers to Solve Practical Limitations of Frequency Transfer
Xu, D., Lopez, O., Amy‐Klein, A., & Pottie, P.-É. (2021) · Journal of Lightwave Technology · doi:10.1109/jlt.2021.3057804 · Cited by 12
Self-citationOptical frequency reference based on a cryogenic silicon resonator
Wiens, E., Kwong, C. J., Müller, T., Bongs, K., Singh, Y., & Schiller, S. (2023) · Optics Express · doi:10.1364/oe.497365 · Cited by 11
Tian, H., Cai, Y. J., Yang, T., Wang, Q., Wang, X., Lin, B., Meng, F., Li, Y., Fang, Z., Steinmeyer, G., et al. (2024) · Applied Physics Letters · doi:10.1063/5.0238480 · Cited by 9
Jitter analysis of timing-distribution and remote-laser synchronization systems
Şafak, K., Xin, M., Zhang, Q., Chia, S., Mücke, O. D., & Käertner, F. X. (2016) · Optics Express · doi:10.1364/oe.24.021752 · Cited by 11
Metadata
- Authors
- Lisdat, C., Grosche, G., Quintin, N., Shi, C., Raupach, S. M. F., Grebing, C., Nicolodi, D., Stefani, F., Al-Masoudi, A., Dörscher, S., Häfner, S., Robyr, J.-L., Chiodo, N., Bilicki, S., Bookjans, E., Koczwara, A., Koke, S., Kuhl, A., Wiotte, F., Meynadier, F., Camisard, E., Abgrall, M., Lours, M., Legero, T., Schnatz, H., Sterr, U., Denker, H., Chardonnet, C., Le Coq, Y., Santarelli, G., Amy-Klein, A., Le Targat, R., Lodewyck, J., Lopez, O., & Pottie, P.-E.
- Affiliations
- Physikalisch-Technische Bundesanstalt (DE)
- Centre National de la Recherche Scientifique (FR)
- Leibniz University Hannover (DE)
- Corresponding author
- Grosche, G.
- ORCID
- Venue
- Nature Communications
- Published
- 2016-08-09
- Volume
- 7
- Issue
- 1
- Pages
- 12443-12443
- ISSN
- 2041-1723 (ISSN-L)
- PMC
- PMC4980484
- OpenAlex
- W2233029113
- Semantic Scholar
- 0d0794a04d9b1159270897744230019a8f367c40
- Cited by
- 460
- References
- 53
- Citations by year
- 2026: 27 · 2025: 49 · 2024: 46 · 2023: 48 · 2022: 51 · 2021: 35 · 2020: 50 · 2019: 41 · 2018: 51 · 2017: 46 · 2016: 16
- FWCI
- 24.26
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by-sa
- creativecommons.org/licenses/by/4.0 (tdm)
- creativecommons.org/licenses/by/4.0 (vor)
- Locations
- Nature Communications (publishedVersion, cc-by-sa)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- arXiv (Cornell University) (submittedVersion)
- Institutional Repository of Leibniz Universität Hannover (Leibniz Universität Hannover) (submittedVersion, cc-by-nc-nd)
- HAL (submittedVersion, cc-by-nc)
- RePEc: Research Papers in Economics (submittedVersion)
- CINECA IRIS Institutial research information system (University of Pisa) (submittedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- arXiv (Cornell University)
- Leibniz Universität Hannover (cc-by)
- Funders
- European Association of National Metrology Institutes (SIB-02)
- Equipex
- European Commission
- Deutsche Forschungsgemeinschaft (CRC 1128 (“geo-Q”, RTG 1729, CRC 1128)
- Agence Nationale de la Recherche (Labex First-TF ANR-10-LABX-48-01, ANR 10 LABX 48 01, First-TF ANR-10-LABX-48-01, ANR blanc LIOM 2011-BS04-009-01, 009-01, 10-LABX-48-01, BS04-009-01, ANR-10-LABX-48, ANR-11-EQPX-0039, ANR-10, ANR-10-LABX, 2011-BS04-009-01)
- Centre National d’Etudes Spatiales
- Centre National de la Recherche Scientifique
- Leibniz-Gemeinschaft
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Frequency and Time Standards
- Physical Sciences › Computer Science › Computer Networks and Communications › Network Time Synchronization Technologies
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Quantum Information and Cryptography
- Keywords
- optical frequency transfer, clock distribution, geodesy, fundamental physics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
The claim verdicts this report counts are experimental: their accuracy is not yet measured.
A language model drew the claims from the paper on 2026-10-10, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-10 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (gpt-6-sol).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.