CoChat

A clock network for geodesy and fundamental science

Open access

The DOI matches its Crossref record; 47 of the 53 references it cites were found in a registry or an index; 18 of the 22 sources its claims cite were checked for support.

Abstract

Leveraging the unrivalled performance of optical clocks as key tools for geo-science, for astronomy and for fundamental physics beyond the standard model requires comparing the frequency of distant optical clocks faithfully. Here, we report on the comparison and agreement of two strontium optical clocks at an uncertainty of 5 × 10(-17) via a newly established phase-coherent frequency link connecting Paris and Braunschweig using 1,415 km of telecom fibre. The remote comparison is limited only by the instability and uncertainty of the strontium lattice clocks themselves, with negligible contributions from the optical frequency transfer. A fractional precision of 3 × 10(-17) is reached after only 1,000 s averaging time, which is already 10 times better and more than four orders of magnitude faster than any previous long-distance clock comparison. The capability of performing high resolution international clock comparisons paves the way for a redefinition of the unit of time and an all-optical dissemination of the SI-second.

Overview

CoChat Summary

TL;DR

The paper demonstrates a direct all-optical comparison of two independent strontium lattice clocks in Paris and Braunschweig over 1,415 km of telecom fibre, achieving agreement at the 5 × 10−17 level. The fibre link contributes negligibly to the measurement, making the clock performance itself the limiting factor.

Key findings

  • Two remote strontium optical clocks were compared with an uncertainty of 5 × 10−17 via a phase-coherent fibre link spanning 1,415 km of telecom fibre.
  • A fractional precision of 3 × 10−17 was reached after 1,000 s averaging time, described as 10 times better and more than four orders of magnitude faster than any previous long-distance clock comparison.
  • In the more extensive second campaign, the fractional offset between the clocks was (4.7 ± 5.0) × 10−17, with agreement within the combined uncertainties.
  • The optical link’s fractional uncertainty was assessed as 2.5 × 10−19, and its instability averaged down faster than the clocks, so the remote comparison was limited by the clocks themselves.

Methods

  • Two independent strontium optical lattice clocks were operated at LNE-SYRTE in Paris and PTB in Braunschweig; their frequencies were transferred to Strasbourg through stabilized fibre links and compared using femtosecond frequency combs.
  • The study analyzed two measurement campaigns (March and June 2015) with 145 h of accumulated data; frequency ratios were corrected for systematic shifts, gravity-potential/redshift differences, and counter synchronization offsets.
  • The main analysis combined local clock-to-transfer-laser comparisons, link-noise-cancelled fibre transfer, and Allan-deviation-based uncertainty evaluation for clock, link, and synchronization contributions.

Limitations

  • The paper states that the comparison is limited by the instability and uncertainty of the strontium lattice clocks themselves, not by the optical transfer system.
  • During the first campaign, counter gates in Paris and Strasbourg were accidentally not synchronized to UTC, requiring indirect reconstruction of the offset with an uncertainty of 10 ms; this is a stated experimental complication.
  • Evident from the text: the results are for two clocks of the same species and under a specific fibre-network configuration, so the paper does not directly test broader clock types or fully general network conditions.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.1038/ncomms12443

Cites

47 of 47 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Figures

Figure 1 Schematic of the clock comparison. The strontium lattice clocks are located at the national metrology institutes SYRTE and PTB in Paris and Braunschweig, respectively. The course and lay-out of the fibre link sections to Strasbourg (705 km from Paris, 710 km from Braunschweig) are indicated on the map. Additionally, the individual setups consisting of a clock laser, optical lattice, fs frequency comb, transfer laser and stabilized link are shown schematically. In Strasbourg, the frequency difference between the transfer lasers is measured. For details see the main text and Methods. Country border data available at http://thematicmapping.org/ under a Creative Commons Attribution-ShareAlike 3.0 Unported. Full terms at http://creativecommons.org/licenses/by-sa/3.0/.
Figure 1 Schematic of the clock comparison. The strontium lattice clocks are located at the national metrology institutes SYRTE and PTB in Paris and Braunschweig, respectively. The course and lay-out of the fibre link sections to Strasbourg (705 km from Paris, 710 km from Braunschweig) are indicated on the map. Additionally, the individual setups consisting of a clock laser, optical lattice, fs frequency comb, transfer laser and stabilized link are shown schematically. In Strasbourg, the frequency difference between the transfer lasers is measured. For details see the main text and Methods. Country border data available at http://thematicmapping.org/ under a Creative Commons Attribution-ShareAlike 3.0 Unported. Full terms at http://creativecommons.org/licenses/by-sa/3.0/.CC BY · PubMed Central
Figure 2 Instability of the clock comparison. The instability is expressed as total Allan deviation σy, as a function of averaging time τ for the first (circles; modified Julian date MJD 57092) and second measurement campaign (diamonds; MJD 57177–57198). We attribute the slightly different instabilities to different clock performances. An instability of 1.2 × 10−15 (τ/s)−1/2 is observed during the first campaign (red line). A statistical measurement uncertainty of 2 × 10−17 is thus achieved after only 3,000 s measurement time. The squares with connecting lines show the link's contribution to the statistical uncertainty for the data recorded in the 2nd campaign (see Methods). The error bars indicate 1σ uncertainties.
Figure 2 Instability of the clock comparison. The instability is expressed as total Allan deviation σy, as a function of averaging time τ for the first (circles; modified Julian date MJD 57092) and second measurement campaign (diamonds; MJD 57177–57198). We attribute the slightly different instabilities to different clock performances. An instability of 1.2 × 10−15 (τ/s)−1/2 is observed during the first campaign (red line). A statistical measurement uncertainty of 2 × 10−17 is thus achieved after only 3,000 s measurement time. The squares with connecting lines show the link's contribution to the statistical uncertainty for the data recorded in the 2nd campaign (see Methods). The error bars indicate 1σ uncertainties.CC BY · PubMed Central
Figure 3 Frequency ratio (−1). (a) Time trace of the valid data. (b) Aggregate segments of 6,000 s length (1st campaign) and 125,000 s (2nd campaign). Error bars (1σ) include statistical and systematic uncertainties (Table 1). The error bars are dominated by the systematic uncertainty, which is not reduced further by averaging. On average, the clocks agree within the ±1σ interval of uncertainty (shaded area) around the expected result of zero, demonstrating the very good agreement between the two systems.
Figure 3 Frequency ratio (−1). (a) Time trace of the valid data. (b) Aggregate segments of 6,000 s length (1st campaign) and 125,000 s (2nd campaign). Error bars (1σ) include statistical and systematic uncertainties (Table 1). The error bars are dominated by the systematic uncertainty, which is not reduced further by averaging. On average, the clocks agree within the ±1σ interval of uncertainty (shaded area) around the expected result of zero, demonstrating the very good agreement between the two systems.CC BY · PubMed Central

Verification

Claims the paper makes

8 Valid · 3 Not valid · 2 Not checked · 35 Own results and interpretations

28 more claims · 1 with their cited sources checked

Create a free account to see all 48 claims and every source verdict.

See all claims — free account
  • It may state two separate claims as one. 12
  • Probably not a substantial claim. 3
  • The quote only partly states this claim. 1

Create a free account to see these claims.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

8 more claims about this paper

Create a free account to see every claim other papers make about this one.

See all claims — free account

Citations

Cites

Research works printed but not linked: 1

  1. Vermeer, M. Chronometric levelling, Reports of the Finnish Geodetic Institute 83, 2 (1983).

Cited by

See all 460

Metadata

Authors
Lisdat, C., Grosche, G., Quintin, N., Shi, C., Raupach, S. M. F., Grebing, C., Nicolodi, D., Stefani, F., Al-Masoudi, A., Dörscher, S., Häfner, S., Robyr, J.-L., Chiodo, N., Bilicki, S., Bookjans, E., Koczwara, A., Koke, S., Kuhl, A., Wiotte, F., Meynadier, F., Camisard, E., Abgrall, M., Lours, M., Legero, T., Schnatz, H., Sterr, U., Denker, H., Chardonnet, C., Le Coq, Y., Santarelli, G., Amy-Klein, A., Le Targat, R., Lodewyck, J., Lopez, O., & Pottie, P.-E.
Affiliations
  • Physikalisch-Technische Bundesanstalt (DE)
  • Centre National de la Recherche Scientifique (FR)
  • Leibniz University Hannover (DE)
Corresponding author
Grosche, G.
Venue
Nature Communications
Published
2016-08-09
Volume
7
Issue
1
Pages
12443-12443
ISSN
2041-1723 (ISSN-L)
OpenAlex
W2233029113
Cited by
460
References
53
Citations by year
2026: 27 · 2025: 49 · 2024: 46 · 2023: 48 · 2022: 51 · 2021: 35 · 2020: 50 · 2019: 41 · 2018: 51 · 2017: 46 · 2016: 16
FWCI
24.26
Type
journal article
Language
en
Open access
Licence
Locations
  • Nature Communications (publishedVersion, cc-by-sa)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • arXiv (Cornell University) (submittedVersion)
  • Institutional Repository of Leibniz Universität Hannover (Leibniz Universität Hannover) (submittedVersion, cc-by-nc-nd)
  • HAL (submittedVersion, cc-by-nc)
  • RePEc: Research Papers in Economics (submittedVersion)
  • CINECA IRIS Institutial research information system (University of Pisa) (submittedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
  • arXiv (Cornell University)
  • Leibniz Universität Hannover (cc-by)
Funders
  • European Association of National Metrology Institutes (SIB-02)
  • Equipex
  • European Commission
  • Deutsche Forschungsgemeinschaft (CRC 1128 (“geo-Q”, RTG 1729, CRC 1128)
  • Agence Nationale de la Recherche (Labex First-TF ANR-10-LABX-48-01, ANR 10 LABX 48 01, First-TF ANR-10-LABX-48-01, ANR blanc LIOM 2011-BS04-009-01, 009-01, 10-LABX-48-01, BS04-009-01, ANR-10-LABX-48, ANR-11-EQPX-0039, ANR-10, ANR-10-LABX, 2011-BS04-009-01)
  • Centre National d’Etudes Spatiales
  • Centre National de la Recherche Scientifique
  • Leibniz-Gemeinschaft
Topics
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Frequency and Time Standards
  • Physical Sciences › Computer Science › Computer Networks and Communications › Network Time Synchronization Technologies
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Quantum Information and Cryptography
Keywords
optical frequency transfer, clock distribution, geodesy, fundamental physics

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

The claim verdicts this report counts are experimental: their accuracy is not yet measured.

A language model drew the claims from the paper on 2026-10-10, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-10-10 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Cited sources are checked with a language model’s help (gpt-6-sol).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.