A clock network for geodesy and fundamental science
Open accessThe DOI matches its Crossref record; 47 of the 53 references it cites were found in a registry or an index; 18 of the 22 sources its claims cite were checked for support.
Abstract
Leveraging the unrivalled performance of optical clocks as key tools for geo-science, for astronomy and for fundamental physics beyond the standard model requires comparing the frequency of distant optical clocks faithfully. Here, we report on the comparison and agreement of two strontium optical clocks at an uncertainty of 5 × 10(-17) via a newly established phase-coherent frequency link connecting Paris and Braunschweig using 1,415 km of telecom fibre. The remote comparison is limited only by the instability and uncertainty of the strontium lattice clocks themselves, with negligible contributions from the optical frequency transfer. A fractional precision of 3 × 10(-17) is reached after only 1,000 s averaging time, which is already 10 times better and more than four orders of magnitude faster than any previous long-distance clock comparison. The capability of performing high resolution international clock comparisons paves the way for a redefinition of the unit of time and an all-optical dissemination of the SI-second.
Overview
CoChat Summary
TL;DR
The paper demonstrates a direct all-optical comparison of two independent strontium lattice clocks in Paris and Braunschweig over 1,415 km of telecom fibre, achieving agreement at the 5 × 10−17 level. The fibre link contributes negligibly to the measurement, making the clock performance itself the limiting factor.
Key findings
- Two remote strontium optical clocks were compared with an uncertainty of 5 × 10−17 via a phase-coherent fibre link spanning 1,415 km of telecom fibre.
- A fractional precision of 3 × 10−17 was reached after 1,000 s averaging time, described as 10 times better and more than four orders of magnitude faster than any previous long-distance clock comparison.
- In the more extensive second campaign, the fractional offset between the clocks was (4.7 ± 5.0) × 10−17, with agreement within the combined uncertainties.
- The optical link’s fractional uncertainty was assessed as 2.5 × 10−19, and its instability averaged down faster than the clocks, so the remote comparison was limited by the clocks themselves.
Methods
- Two independent strontium optical lattice clocks were operated at LNE-SYRTE in Paris and PTB in Braunschweig; their frequencies were transferred to Strasbourg through stabilized fibre links and compared using femtosecond frequency combs.
- The study analyzed two measurement campaigns (March and June 2015) with 145 h of accumulated data; frequency ratios were corrected for systematic shifts, gravity-potential/redshift differences, and counter synchronization offsets.
- The main analysis combined local clock-to-transfer-laser comparisons, link-noise-cancelled fibre transfer, and Allan-deviation-based uncertainty evaluation for clock, link, and synchronization contributions.
Limitations
- The paper states that the comparison is limited by the instability and uncertainty of the strontium lattice clocks themselves, not by the optical transfer system.
- During the first campaign, counter gates in Paris and Strasbourg were accidentally not synchronized to UTC, requiring indirect reconstruction of the offset with an uncertainty of 10 ms; this is a stated experimental complication.
- Evident from the text: the results are for two clocks of the same species and under a specific fibre-network configuration, so the paper does not directly test broader clock types or fully general network conditions.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Figures



Verification
Claims the paper makes
8 Valid · 3 Not valid · 2 Not checked · 35 Own results and interpretations
The sources with a verdict support this claim; the rest weren’t checked yet, have no full text we could read, or their verdicts aren’t rated yet.
In the paper
“Our work not only enables the above mentioned applications, but also clears the path towards a redefinition of the unit of time, the SI second2425 through regular and practical international comparisons of optical clocks.”
§ A clock network for geodesy and fundamental science > Abstract
What the sources say
- Supportedcites [24] Riehle, F. Towards a redefinition of the second based on optical atomic clocks. C. R. Physique 16, 506–515 (2015). source
The Abstract (p. 1) identifies ways to compare remote optical clocks among the prerequisites for a future redefinition of the SI second. Section 4 (p. 12) discusses international clock comparisons and practical links for carrying them out. The citing authors’ statement that their own work ‘clears the path’ is their conclusion, not a finding attributed to Riehle. (LLM, conf=0.88)
- Not checked — no full text of the sourcecites [25] Margolis, H. Timekeepers of the future. Nat. Phys. 10, 82–83 (2014). source
boostedstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
Every source the paper cites for this claim was checked and supports it.
In the paper
“satellite link techniques do not reach significantly better performance either.”
§ A clock network for geodesy and fundamental science > Abstract
What the sources say
- Supportedcites [20] Hachisu, H. et al. Direct comparison of optical lattice clocks with an intercontinental baseline of 9000, km. Opt. Lett. 39, 4072–4075 (2014). source
On p. 3, the paper reports a 1.6 × 10⁻¹⁵ uncertainty for its satellite-linked clock comparison and gives 6 × 10⁻¹⁶ for a comparison using local Cs fountain clocks. Its p. 1 discussion also describes the performance limits of the GPSCP and TWCP satellite techniques. These passages support the claim that the satellite links did not deliver substantially better performance than the microwave-clock comparison discussed. (LLM, conf=0.84)
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“Complemented by phase-coherent telecom fibre links9101112 as extremely powerful tools for frequency dissemination on a continental scale”
§ A clock network for geodesy and fundamental science > Abstract
What the sources say
- Not checked — no full text of the sourcecites [9] Predehl, K. et al. A 920-Kilometer optical fiber link for frequency metrology at the 19th decimal place. Science 336, 441–444 (2012). source
- Supportedcites [10] Lopez, O. et al. Ultra-stable long distance optical frequency distribution using the Internet fiber network. Opt. Express 20, 23518–23526 (2012). source
The Introduction (p. 3) describes a phase-stabilized 540 km link on a public telecom network for disseminating ultra-stable optical signals and calls the approach scalable. It also discusses extending frequency distribution to a larger scale, supporting the claim about these links as tools for continental-scale dissemination. (LLM, conf=0.86)
- Partly supportedcites [11] Calosso, C. E. et al. Doppler-stabilized fiber link with 6 dB noise improvement below the classical limit. Opt. Lett. 40, 131–134 (2015). sourceExperimental — accuracy not yet measured
The passage labeled Abstract (p. 2) calls optical fiber links a key tool for frequency dissemination and describes coherent links using standard telecom fiber. But the reported experiment used a 47 km metropolitan link (Abstract, pp. 1, 3); our copy does not establish frequency dissemination on a continental scale. (LLM, conf=0.84)
boosted- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“The details of the actual implementation of state preparation and interrogation being quite different in the two experimental realizations of a Sr lattice clock5212223, systematic and statistical uncertainties are highly independent and uncorrelated.”
§ A clock network for geodesy and fundamental science > Results > Optical clock performance
What the sources say
- Partly supportedcites [5] Le Targat, R. et al. Experimental realization of an optical second with strontium lattice clocks. Nat. Commun. 4, 2109 (2013). sourceExperimental — accuracy not yet measured
The OLC architecture section says the two Sr clocks differ in key features, and the Figure 3 caption treats their combined systematic uncertainty as that of two uncorrelated clocks. Figure 1 describes independent probe feedback, but the paper does not establish that state preparation and interrogation are quite different or explicitly say that the clocks’ statistical uncertainties are uncorrelated. (LLM, conf=0.82)
- Could not verifycites [21] Falke, S. et al. A strontium lattice clock with 3 × 10−17 inaccuracy and its frequency. New J. Phys. 16, 073023 (2014). sourceExperimental — accuracy not yet measured
Section 2 describes the preparation and interrogation of this paper’s Sr clock, and section 5 compares its measured frequency with results from other laboratories. Neither passage describes differences between two Sr-clock implementations or says that their systematic and statistical uncertainties are independent or uncorrelated. Searches for those terms and the claimed comparison found no supporting passage. (LLM, conf=0.76)
- Could not verifycites [22] Grebing, C. et al. Realization of a time-scale with an optical clock. Optica 3, 563–569 (2016). sourceExperimental — accuracy not yet measured
Section II (p. 2) describes one Sr lattice clock operated in two campaigns, and the Supplementary Material (p. 7) describes its preparation and interrogation. The paper does not compare the implementations of two Sr clocks or say that their systematic and statistical uncertainties are uncorrelated; the independence mentioned in Data Analysis (p. 3) concerns two Cs fountain clocks. (LLM, conf=0.76)
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“This international all-optical clock measurement surpasses the accuracy of the best possible comparison achievable by measurements against primary caesium clocks by one order of magnitude5212223.”
§ A clock network for geodesy and fundamental science > Results > Campaigns to compare the strontium optical clocks
What the sources say
- Partly supportedcites [5] Le Targat, R. et al. Experimental realization of an optical second with strontium lattice clocks. Nat. Commun. 4, 2109 (2013). sourceExperimental — accuracy not yet measured
The Discussion (page unavailable) reports that a direct comparison of two strontium optical clocks achieved agreement better than three of the best caesium fountains could resolve. But the reported optical comparison uncertainty was 1.5 × 10⁻¹⁶ versus 3.1 × 10⁻¹⁶ for the caesium-based comparison—not an order of magnitude—and the Discussion describes comparisons between clocks at different institutes as future work, not this measurement. (LLM, conf=0.88)
- Partly supportedcites [21] Falke, S. et al. A strontium lattice clock with 3 × 10−17 inaccuracy and its frequency. New J. Phys. 16, 073023 (2014). sourceExperimental — accuracy not yet measured
The Introduction (page not available) says the best caesium fountain clocks limit absolute frequency measurements to about 2–4 × 10⁻¹⁶. Results and discussion (page not available) says direct optical-clock comparisons achieve smaller relative uncertainties, but does not quantify a tenfold advantage for an international all-optical measurement. This paper’s own absolute measurement used caesium fountains, so its nearly tenfold advantage refers to the strontium clock’s systematic uncertainty, not that measurement’s accuracy. (LLM, conf=0.85)
- Partly supportedcites [22] Grebing, C. et al. Realization of a time-scale with an optical clock. Optica 3, 563–569 (2016). sourceExperimental — accuracy not yet measured
Optical Clock Operation (p. 2) says the strontium clock’s systematic uncertainty is at least an order of magnitude below that of PTB’s primary caesium fountains. But this paper’s measurement compares a local strontium clock with caesium fountains; Data Analysis (p. 4) discusses agreement with measurements at other institutes, not the accuracy of the cited international all-optical measurement. (LLM, conf=0.86)
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
28 more claims · 1 with their cited sources checked
Create a free account to see all 48 claims and every source verdict.
- It may state two separate claims as one. 12
- Probably not a substantial claim. 3
- The quote only partly states this claim. 1
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Furthermore, the frequency of two atomic clocks can be compared via an interferometric fiber link (IFL), which supports sub-10 -19 accuracy over hundreds of kilometers [5-10].”
From Long-distance chronometric leveling with a portable optical clock (2024) · cites this paper as [6]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Phase compensated optical fiber links enable high accuracy atomic clocks separated by thousands of kilometers to be compared with unprecedented statistical resolution.”
From Test of Special Relativity Using a Fiber Network of Optical Clocks (2017) · cites this paper as [9]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“They reached the accuracy of 3×10 -17 using two Sr-lattice clocks with an uncertainty of 5×10 -17 between Paris and Braunschweig stations.”
From Time transfer and significance of vertical land motion in relativistic geodesy applications: a review paper (2023) · cites this paper as Lisdat et al. (2016)
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“A first attempt in this direction was the comparison of two strontium optical clocks between PTB and OBSPARIS via a fibre link, showing an uncertainty and agreement with the geodetic results of about 5 × 10 -17 (Lisdat et al. 2016).”
From Geodetic methods to determine the relativistic redshift at the level of 10 $$^{-18}$$ - 18 in the context of international timescales: a review and practical results (2018) · cites this paper as Lisdat et al. 2016
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Therefore, phase-coherent optical links have been developped using principally an optical fibre as a medium for the propagation [108, 109, 75, 74], attaining spectacular stability and accuracy in the range 10 -19 and below.”
From Chronometric Geodesy: Methods and Applications (2019) · cites this paper as [75]
Experimental — accuracy not yet measured
8 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Frequency Ratio of Al+and Hg+Single-Ion Optical Clocks; Metrology at the 17th Decimal Place
Rosenband, T., Hume, D. B., Schmidt, P. O., Chou, C. W., Brusch, A., Lorini, L., Oskay, W. H., Drullinger, R. E., Fortier, T. M., Stalnaker, J. E., et al. (2008) · Science · doi:10.1126/science.1154622 · Cited by 1,450
An optical lattice clock with accuracy and stability at the 10−18 level
Bloom, B. J., Nicholson, T. L., Williams, J. R., Campbell, S. L., Bishof, M., Zhang, X., Zhang, W., Bromley, S. L., & Ye, J. (2014) · Nature · doi:10.1038/nature12941 · Cited by 1,073
Nobel Lecture: Passion for precision
Hänsch, T. W. (2006) · Reviews of Modern Physics · doi:10.1103/revmodphys.78.1297 · Cited by 915
Frequency Comparison of Two High-Accuracy Al + Optical Clocks
Chou, C., Hume, D., Koelemeij, J., Wineland, D., & Rosenband, T. (2010) · Physical Review Letters · doi:10.1103/physrevlett.104.070802 · Cited by 903
Chou, C. W., Hume, D. B., Rosenband, T., & Wineland, D. J. (2010) · Science · doi:10.1126/science.1192720 · Cited by 828
An Atomic Clock with 10 –18 Instability
Hinkley, N., Sherman, J. A., Phillips, N. B., Schioppo, M., Lemke, N. D., Beloy, K., Pizzocaro, M., Oates, C. W., & Ludlow, A. D. (2013) · Science · doi:10.1126/science.1240420 · Cited by 817 · cited 1×
“Optical clocks are – due to their orders of magnitude better precision (1) and accuracy (2,3,4) than their microwave counterparts realizing the definition of the SI second – new sensors with highest resolving power to, e.”
BackgroundSystematic evaluation of an atomic clock at 2 × 10−18 total uncertainty
Nicholson, T. L., Campbell, S. L., Hutson, R. B., Marti, G. E., Bloom, B. J., McNally, R. L., Zhang, W., Barrett, M. D., Safronova, M. S., Strouse, G. F., et al. (2015) · Nature Communications · doi:10.1038/ncomms7896 · Cited by 780 · cited 1×
“Optical clocks are – due to their orders of magnitude better precision (1) and accuracy (2,3,4) than their microwave counterparts realizing the definition of the SI second – new sensors with highest resolving power to, e.”
BackgroundKómár, P., Kessler, E. M., Bishof, M., Jiang, L., Sørensen, A. S., Ye, J., & Lukin, M. D. (2014) · Nature Physics · doi:10.1038/nphys3000 · Cited by 768 · cited 1×
“Additionally, new geodetic reference frames based on relativistic geodesy (15,16) or a quantum network of clocks (17) can be established.”
BackgroundCryogenic optical lattice clocks
Ushijima, I., Takamoto, M., Das, M., Ohkubo, T., & Katori, H. (2015) · Nature Photonics · doi:10.1038/nphoton.2015.5 · Cited by 627 · cited 1×
“Optical clocks are – due to their orders of magnitude better precision (1) and accuracy (2,3,4) than their microwave counterparts realizing the definition of the SI second – new sensors with highest resolving power to, e.”
BackgroundNobel Lecture: Defining and measuring optical frequencies
Hall, J. L. (2006) · Reviews of Modern Physics · doi:10.1103/revmodphys.78.1279 · Cited by 614
Research works printed but not linked: 1
- Vermeer, M. Chronometric levelling, Reports of the Finnish Geodetic Institute 83, 2 (1983).
Cited by
20 years of developments in optical frequency comb technology and applications
Fortier, T., & Baumann, E. (2019) · Communications Physics · doi:10.1038/s42005-019-0249-y · Cited by 963
Geodesy and metrology with a transportable optical clock
Grotti, J., Koller, S., Vogt, S., Häfner, S., Sterr, U., Lisdat, C., Denker, H., Voigt, C., Timmen, L., Rolland, A., et al. (2018) · Nature Physics · doi:10.1038/s41567-017-0042-3 · Cited by 495
“Its path was equipped with two dedicated bidirectional erbium-doped fibre amplifiers that allowed a phase stable signal to be generated at LSM through the Doppler noise cancellation technique 17,18 .”
InfluentialSelf-citationUltrastable laser interferometry for earthquake detection with terrestrial and submarine cables
Marra, G., Clivati, C., Luckett, R., Tampellini, A., Kronjäger, J., Wright, L., Mura, A., Levi, F., Robinson, S., Xuereb, A., et al. (2018) · Science · doi:10.1126/science.aat4458 · Cited by 407
“Metrological optical links up to 2,200 km long already connect some of the largest NMIs in Europe and network expansion is underway (17-20).”
BackgroundFrequency ratio measurements at 18-digit accuracy using an optical clock network
Boulder Atomic Clock Optical Network (BACON) Collaboration*, Beloy, K., Bodine, M. I., Bothwell, T., Brewer, S. M., Bromley, S. L., Chen, J.-S., Deschênes, J.-D., Diddams, S. A., Fasano, R. J., et al. (2021) · Nature · doi:10.1038/s41586-021-03253-4 · Cited by 390
Self-citationUltrastable optical clock with two cold-atom ensembles
Schioppo, M., Brown, R. C., McGrew, W. F., Hinkley, N., Fasano, R. J., Beloy, K., Yoon, T. H., Milani, G., Nicolodi, D., Sherman, J. A., et al. (2017) · Nature Photonics · doi:10.1038/nphoton.2016.231 · Cited by 385
Self-citationThe CIPM list of recommended frequency standard values: guidelines and procedures
Riehle, F., Gill, P., Arias, F., & Robertsson, L. (2018) · Metrologia · doi:10.1088/1681-7575/aaa302 · Cited by 281
“the Sr lattice clocks at SYRTE, NPL and PTB can be compared with such an uncertainty in the different laboratories linked via already-established fibre links [95, 103, 109].”
BackgroundEntanglement on an optical atomic-clock transition
Pedrozo-Peñafiel, E., Colombo, S., Shu, C., Adiyatullin, A. F., Li, Z., Mendez, E., Braverman, B., Kawasaki, A., Akamatsu, D., Xiao, Y., et al. (2020) · Nature · doi:10.1038/s41586-020-3006-1 · Cited by 275
Riehle, F. (2017) · Nature Photonics · doi:10.1038/nphoton.2016.235 · Cited by 264
Mehlstäubler, T. E., Grosche, G., Lisdat, C., Schmidt, P. O., & Denker, H. (2018) · Reports on Progress in Physics · doi:10.1088/1361-6633/aab409 · Cited by 263
“…the accuracy of this clock comparison — corresponding to about 18 m in terms of height difference — did not reach the resolution demonstrated by Lisdat et al (2016) and Takano et al (2016) or , it was the first demonstration of a full chronometric levelling experiment with an optical clock,…”
InfluentialSelf-citationGeopotential measurements with synchronously linked optical lattice clocks
Takano, T., Takamoto, M., Ushijima, I., Ohmae, N., Akatsuka, T., Yamaguchi, A., Kuroishi, Y., Munekane, H., Miyahara, B., & Katori, H. (2016) · Nature Photonics · doi:10.1038/nphoton.2016.159 · Cited by 245
Loss in hollow-core optical fibers: mechanisms, scaling rules, and limits
Numkam Fokoua, E., Abokhamis Mousavi, S., Jasion, G. T., Richardson, D. J., & Poletti, F. (2023) · Advances in Optics and Photonics · doi:10.1364/aop.470592 · Cited by 245
Transportable Optical Lattice Clock with 7 × 10 − 17 Uncertainty
Koller, S. B., Grotti, J., Vogt, S., Al-Masoudi, A., Dörscher, S., Häfner, S., Sterr, U., & Lisdat, C. (2017) · Physical Review Letters · doi:10.1103/physrevlett.118.073601 · Cited by 238
Self-citationTest of Special Relativity Using a Fiber Network of Optical Clocks
Delva, P., Lodewyck, J., Bilicki, S., Bookjans, E., Vallet, G., Le Targat, R., Pottie, P.-E., Guerlin, C., Meynadier, F., Le Poncin-Lafitte, C., et al. (2017) · Physical Review Letters · doi:10.1103/physrevlett.118.221102 · Cited by 227
Self-citationWhite Rabbit Precision Time Protocol on Long-Distance Fiber Links
Dierikx, E. F., Wallin, A. E., Fordell, T., Myyry, J., Koponen, P. S., Merimaa, M., Pinkert, T. J., Koelemeij, J. C. J., Peek, H., & Smets, R. (2016) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2016.2518122 · Cited by 162
Origlia, S., Pramod, M. S., Schiller, S., Singh, Y., Bongs, K., Schwarz, R., Al-Masoudi, A., Dörscher, S., Herbers, S., Häfner, S., et al. (2018) · Physical Review A · doi:10.1103/physreva.98.053443 · Cited by 142
Self-citationRoadmap towards the redefinition of the second
Dimarcq, N., Gertsvolf, M., Mileti, G., Bize, S., Oates, C. W., Peik, E., Calonico, D., Ido, T., Tavella, P., Meynadier, F., et al. (2023) · Metrologia · doi:10.1088/1681-7575/ad17d2 · Cited by 205
“→ Fulfilment level: 70%–90% [39, 87, 92–94] and www. bipm.org/en/time-ftp/data.”
BackgroundSelf-citationDetecting dark-matter waves with a network of precision-measurement tools
Derevianko, A. (2018) · Physical Review A · doi:10.1103/physreva.97.042506 · Cited by 141
Free-space dissemination of time and frequency with 10−19 instability over 113 km
Shen, Q., Guan, J.-Y., Ren, J.-G., Zeng, T., Hou, L., Li, M., Cao, Y. W., Han, J.-J., Lian, M.-Z., Chen, Y., et al. (2022) · Nature · doi:10.1038/s41586-022-05228-5 · Cited by 167
Coherent phase transfer for real-world twin-field quantum key distribution
Clivati, C., Meda, A., Donadello, S., Virzì, S., Genovese, M., Levi, F., Mura, A., Pittaluga, M., Yuan, Z. L., Shields, A. J., et al. (2022) · Nature Communications · doi:10.1038/s41467-021-27808-1 · Cited by 163
Long-distance telecom-fiber transfer of a radio-frequency reference for radio astronomy
He, Y., Baldwin, K. G. H., Orr, B. J., Warrington, R. B., Wouters, M. J., Luiten, A. N., Mirtschin, P., Tzioumis, A. K., Phillips, C. J., Stevens, J. B., et al. (2018) · Optica · doi:10.1364/optica.5.000138 · Cited by 133
A VLBI experiment using a remote atomic clock via a coherent fibre link
Clivati, C., Ambrosini, R., Artz, T., Bertarini, A., Bortolotti, C., Frittelli, M., Levi, F., Mura, A., Maccaferri, G., Nanni, M., et al. (2017) · Scientific Reports · doi:10.1038/srep40992 · Cited by 123
Essay: Quantum Sensing with Atomic, Molecular, and Optical Platforms for Fundamental Physics
Ye, J., & Zoller, P. (2024) · Physical Review Letters · doi:10.1103/physrevlett.132.190001 · Cited by 142
“…systems with photonics, we can take clock technology out of the laboratory to play an important role in future relativistic geodesy research, where the next generation of optical atomic clocks will help characterize and define the time-dependent properties of the Earth ’ s gravity field [65,66].”
BackgroundSchioppo, M., Kronjäger, J., Silva, A., Ilieva, R., Paterson, J. W., Baynham, C. F. A., Bowden, W., Hill, I. R., Hobson, R., Vianello, A., et al. (2022) · Nature Communications · doi:10.1038/s41467-021-27884-3 · Cited by 118
Self-citationRoberts, B. M., Delva, P., Al-Masoudi, A., Amy‐Klein, A., Bærentsen, C. Ø., Baynham, C. F. A., Benkler, E., Bilicki, S., Bize, S., Bowden, W., et al. (2020) · New Journal of Physics · doi:10.1088/1367-2630/abaace · Cited by 128
Self-citationOperational Magic Intensity for Sr Optical Lattice Clocks
Ushijima, I., Takamoto, M., & Katori, H. (2018) · Physical Review Letters · doi:10.1103/physrevlett.121.263202 · Cited by 116
Quantum Key Distribution over 658 km Fiber with Distributed Vibration Sensing
Chen, J.-P., Zhang, C., Liu, Y., Jiang, C., Zhao, D., Zhang, W., Chen, F., Li, H., You, L., Wang, Z., et al. (2022) · Physical Review Letters · doi:10.1103/physrevlett.128.180502 · Cited by 133
Frequency Measurements of Superradiance from the Strontium Clock Transition
Norcia, M. A., Cline, J. R. K., Muniz, J. A., Robinson, J. M., Hutson, R. B., Goban, A., Marti, G. E., Ye, J., & Thompson, J. K. (2018) · Physical Review X · doi:10.1103/physrevx.8.021036 · Cited by 139
Suslov, D., Komanec, M., Fokoua, E. N., et al. (2021) · Scientific Reports · doi:10.1038/s41598-021-88065-2 · Cited by 103
A compact, transportable single-ion optical clock with 7.8 × 10−17 systematic uncertainty
Cao, J., Zhang, P., Shang, J., Cui, K., Yuan, J., Chao, S., Wang, S., Shu, H., & Huang, X. (2017) · Applied Physics B · doi:10.1007/s00340-017-6671-5 · Cited by 101
Common-clock very long baseline interferometry using a coherent optical fiber link
Clivati, C., Aiello, R., Bianco, G., Bortolotti, C., De Natale, P., Di Sarno, V., Maddaloni, P., Maccaferri, G., Mura, A., Negusini, M., et al. (2020) · Optica · doi:10.1364/optica.393356 · Cited by 99
Quantum-limited optical time transfer for future geosynchronous links
Caldwell, E. D., Deschênes, J.-D., Ellis, J. L., Swann, W. C., Stuhl, B., Bergeron, H., Newbury, N. R., & Sinclair, L. C. (2023) · Nature · doi:10.1038/s41586-023-06032-5 · Cited by 112
Femtosecond time synchronization of optical clocks off of a flying quadcopter
Bergeron, H., Sinclair, L. C., Swann, W. C., Khader, I. H., Cossel, K. C., Cermak, M. A., Deschênes, J.-D., & Newbury, N. R. (2019) · Nature Communications · doi:10.1038/s41467-019-09768-9 · Cited by 100
Denker, H., Timmen, L., Voigt, C., Weyers, S., Peik, E., Margolis, H. S., Delva, P., Wolf, P., & Petit, G. (2018) · Journal of Geodesy · doi:10.1007/s00190-017-1075-1 · Cited by 91
Self-citationContinuous Bose–Einstein condensation
Chen, C.-C., Escudero, R. G., Minář, J., Pasquiou, B., Bennetts, S., & Schreck, F. (2022) · Nature · doi:10.1038/s41586-022-04731-z · Cited by 98
“Creating such a CW source of matter will benefit applications ranging from geodesy [17, 18], to tests of Einstein’s equivalence principle [5, 6], gravitational-wave detection [12, 13, 19– 21], and dark-matter and dark-energy searches [22, 23].”
MethodComparing a mercury optical lattice clock with microwave and optical frequency standards
Tyumenev, R., Favier, M., Bilicki, S., Bookjans, E., Targat, R. L., Lodewyck, J., Nicolodi, D., Coq, Y. L., Abgrall, M., Guéna, J., et al. (2016) · New Journal of Physics · doi:10.1088/1367-2630/18/11/113002 · Cited by 85
Self-citationGuéna, J., Weyers, S., Abgrall, M., Grebing, C., Gerginov, V, Rosenbusch, P., Bize, S., Lipphardt, B., Denker, H., Quintin, N., et al. (2017) · Metrologia · doi:10.1088/1681-7575/aa65fe · Cited by 83
Self-citationOptical frequency standards for time and length applications
Hong, F.-L. (2016) · Measurement Science and Technology · doi:10.1088/1361-6501/28/1/012002 · Cited by 90
“An international comparison of two Sr optical lattice clocks at PTB and SYRTE was undertaken using a 1415 km long optical fibre network to confirm that the two clocks agreed at an uncertainty of 5 × 10−17 [39].”
BackgroundMethodInfluentialPoint-to-point stabilized optical frequency transfer with active optics
Dix-Matthews, B. P., Schediwy, S., Gozzard, D. R., Savalle, E., Esnault, F.-X., Lévèque, T., Gravestock, C., D’Mello, D., Karpathakis, S., Tobar, M. E., et al. (2021) · Nature Communications · doi:10.1038/s41467-020-20591-5 · Cited by 79
Fokoua, E. N., Petrovich, M. N., Bradley, T. D., Poletti, F., Richardson, D. J., & Slavík, R. (2017) · Optica · doi:10.1364/optica.4.000659 · Cited by 75
Comparing Optical Oscillators across the Air to Milliradians in Phase and 10−17 in Frequency
Sinclair, L. C., Bergeron, H., Swann, W. C., Baumann, E., Deschênes, J.-D., & Newbury, N. R. (2018) · Physical Review Letters · doi:10.1103/physrevlett.120.050801 · Cited by 73
Precise time scales and navigation systems: mutual benefits of timekeeping and positioning
Tavella, P., & Petit, G. (2020) · Satellite Navigation · doi:10.1186/s43020-020-00012-0 · Cited by 74
Determination of a high spatial resolution geopotential model using atomic clock comparisons
Lion, G., Panet, I., Wolf, P., Guerlin, C., Bize, S., & Delva, P. (2017) · Journal of Geodesy · doi:10.1007/s00190-016-0986-6 · Cited by 66
“Currently two methods are available for such comparisons, fiber links (Lisdat et al. 2016) and free space optical links (Deschênes et al. 2016).”
BackgroundMethodShen, Q., Guan, J.-Y., Zeng, T., Lu, Q., Huang, L., Cao, Y. W., Chen, J.-P., Tao, T.-Q., Wu, J., Hou, L., et al. (2021) · Optica · doi:10.1364/optica.413114 · Cited by 69
Cold atoms in space: community workshop summary and proposed road-map
Alonso, I., Alpigiani, C., Altschul, B., Araújo, H. M., Arduini, G., Arlt, J., Badurina, L., Balaž, A., Bandarupally, S., Barish, B. C., et al. (2022) · EPJ Quantum Technology · doi:10.1140/epjqt/s40507-022-00147-w · Cited by 59
“Locally, fibreoptical links can be an alternative [39], but a global network is not within reach.”
BackgroundIntercontinental comparison of optical atomic clocks through very long baseline interferometry
Pizzocaro, M., Sekido, M., Takefuji, K., Ujihara, H., Hachisu, H., Nemitz, N., Tsutsumi, M., Kondo, T., Kawai, E., Ichikawa, R., et al. (2021) · Nature Physics · doi:10.1038/s41567-020-01038-6 · Cited by 64
Towards a transportable aluminium ion quantum logic optical clock
Hannig, S., Pelzer, L., Scharnhorst, N., Kramer, J., Stepanova, M., Xu, Z. T., Spethmann, N., Leroux, I. D., Mehlstäubler, T. E., & Schmidt, P. O. (2019) · Review of Scientific Instruments · doi:10.1063/1.5090583 · Cited by 70
Lattice-induced photon scattering in an optical lattice clock
Dörscher, S., Schwarz, R., Al-Masoudi, A., Falke, S., Sterr, U., & Lisdat, C. (2018) · Physical Review A · doi:10.1103/physreva.97.063419 · Cited by 60
Self-citationClone-comb-enabled high-capacity digital-analogue fronthaul with high-order modulation formats
Zhang, C., Zhu, Y., He, B., Lin, J., Liu, R., Xu, Y., Yi, L., Zhuge, Q., Hu, W., Hu, W., et al. (2023) · Nature Photonics · doi:10.1038/s41566-023-01273-2 · Cited by 64
“The synchronization of optical frequency combs supports the frequency comparison of high-precision off-site optical frequency clocks 21,22 .”
BackgroundAn accurate and robust metrological network for coherent optical frequency dissemination
Cantin, E., Tønnes, M., Le Targat, R., Amy-Klein, A., Lopez, O., & Pottie, P.-E. (2021) · New Journal of Physics · doi:10.1088/1367-2630/abe79e · Cited by 59
“Long-term stability (OADEV) of the SYRTE–Strasbourg–SYRTE link (C, solid line and blue squares) and the SYRTE–LPL–SYRTE link (A, solid line and red squares) calculated from the averaged frequencies on periods spanning 2160 s. 31% and 47% of the data have been removed for links A and C respectively.”
BackgroundInfluentialSelf-citationPizzocaro, M., Thoumany, P., Rauf, B., Bregolin, F., Milani, G., Clivati, C., Costanzo, G. A., Levi, F., & Calonico, D. (2017) · Metrologia · doi:10.1088/1681-7575/aa4e62 · Cited by 63
Terahertz Frequency Metrology for Spectroscopic Applications: a Review
Consolino, L., Bartalini, S., & Natale, P. D. (2017) · Journal of Infrared Millimeter and Terahertz Waves · doi:10.1007/s10762-017-0406-x · Cited by 66
“transfer method [191–196], and are also envisioned as key elements for the development of a new kind of high-accuracy relativistic geodesy [195, 197].”
MethodFemtosecond optical two-way time-frequency transfer in the presence of motion
Sinclair, L. C., Bergeron, H., Swann, W. C., Khader, I. H., Cossel, K. C., Cermak, M. A., Newbury, N. R., & Deschênes, J.-D. (2019) · Physical Review A · doi:10.1103/physreva.99.023844 · Cited by 62
Heisenberg-Limited Noisy Atomic Clock Using a Hybrid Coherent and Squeezed State Protocol
Pezzè, L., & Smerzi, A. (2020) · Physical Review Letters · doi:10.1103/physrevlett.125.210503 · Cited by 68
“[3] C.”
BackgroundTowards a transportable aluminium ion quantum logic optical clock
Hannig, S., Pelzer, L., Scharnhorst, N., Kramer, J., Stepanova, M., Xu, Z., Spethmann, N., Leroux, I. D., Mehlstäubler, T. E., & Schmidt, P. O. (2019) · Institutional Repository of Leibniz Universität Hannover (Leibniz Universität Hannover) · doi:10.15488/12800 · Cited by 56
Optical frequency distribution using laser repeater stations with planar lightwave circuits
Akatsuka, T., Goh, T., Imai, H., Oguri, K., Ishizawa, A., Ushijima, I., Ohmae, N., Takamoto, M., Katori, H., Hashimoto, T., et al. (2020) · Optics Express · doi:10.1364/oe.383526 · Cited by 55
Optical frequency transfer over submarine fiber links
Clivati, C., Tampellini, A., Mura, A., Levi, F., Marra, G., Galea, P., Xuereb, A., & Calonico, D. (2018) · Optica · doi:10.1364/optica.5.000893 · Cited by 55
First industrial-grade coherent fiber link for optical frequency standard dissemination
Camargo, F. A., Ménoret, V., Cantin, E., Lopez, O., Quintin, N., Camisard, É., Salmon, V., Merdy, J.-M. L., Santarelli, G., Amy‐Klein, A., et al. (2018) · Applied Optics · doi:10.1364/ao.57.007203 · Cited by 54
“Cascaded link technique was used in Europe for clock comparisons between National Metrology Institutes (NPL, PTB and LNE-SYRTE) [9–11].”
MethodSelf-citationOptical frequency ratio of a 171Yb+ single-ion clock and a 87Sr lattice clock
Dörscher, S., Huntemann, N., Schwarz, R., Lange, R., Benkler, E., Lipphardt, B., Sterr, U., Peik, E., & Lisdat, C. (2020) · Metrologia · doi:10.1088/1681-7575/abc86f · Cited by 61
Self-citationGeopotential measurement with a robust, transportable Ca+ optical clock
Huang, Y., Zhang, H., Zhang, B., Hao, Y., Guan, H., Zeng, M., Chen, Q., Lin, Y., Wang, Y., Cao, S., et al. (2020) · Physical Review A · doi:10.1103/physreva.102.050802 · Cited by 52
GENESIS: co-location of geodetic techniques in space
Delva, P., Altamimi, Z., Blazquez, A., Bloßfeld, M., Böhm, J., Bonnefond, P., Boy, J., Bruinsma, S., Bury, G., Chatzinikos, M., et al. (2023) · Earth Planets and Space · doi:10.1186/s40623-022-01752-w · Cited by 69
“Long-distance optical frequency transfer using phase-stabilized optical fibers has been demonstrated with a relative frequency inaccuracy at the 10−19 level (Lisdat et al., 2016), and even 10−21 on shorter distances (Xu et al., 2019).”
BackgroundVallet, G., Bookjans, E., Eismann, U., Bilicki, S., Targat, R. L., & Lodewyck, J. (2017) · New Journal of Physics · doi:10.1088/1367-2630/aa7c84 · Cited by 52
“Not only have they reached systematic uncertainties in the low 10−18 in fractional frequency units [1, 2], but they have proven to be reliable and reproducible as it has been demonstrated by various measurement and comparison campaigns [3, 4].”
BackgroundSelf-citationThe Companion of Enrico’s Chart for Phase Noise and Two-Sample Variances
Rubiola, E., & Vernotte, F. (2023) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2023.3238267 · Cited by 69
“Phase noise challenges the networks intended for fundamental science and clock comparison between metrological labs using optical fibers shared Internet data traffic [26], [27], [28], [29].”
A strontium lattice clock with both stability and uncertainty below 5 × 10 − 18
Li, J., Cui, X.-Y., Jia, Z.-P., Kong, D.-Q., Yu, H.-W., Zhu, X.-Q., Liu, X., Wang, D., Zhang, X., Huang, X.-Y., et al. (2024) · Metrologia · doi:10.1088/1681-7575/ad1a4c · Cited by 52
Inertial quantum sensors using light and matter
Barrett, B., Bertoldi, A. D., & Bouyer, P. (2016) · Physica Scripta · doi:10.1088/0031-8949/91/5/053006 · Cited by 49
Hobson, R., Bowden, W., Vianello, A., Silva, A., Baynham, C. F. A., Margolis, H. S., Baird, P. E. G., Gill, P. R., & Hill, I. R. (2020) · Metrologia · doi:10.1088/1681-7575/abb530 · Cited by 58
Optically synchronized fibre links using spectrally pure chip-scale lasers
Brodnik, G. M., Harrington, M. W., Dallyn, J. H., Bose, D., Zhang, W., Stern, L., Morton, P. A., Behunin, R. O., Papp, S. B., & Blumenthal, D. J. (2021) · Nature Photonics · doi:10.1038/s41566-021-00831-w · Cited by 57
Optical frequency divider with division uncertainty at the 10−21 level
Yao, Y., Jiang, Y., Yu, H., Bi, Z., & Ma, L. (2016) · National Science Review · doi:10.1093/nsr/nww063 · Cited by 57
Stabilized microwave-frequency transfer using optical phase sensing and actuation
Schediwy, S., Gozzard, D. R., Stobie, S., Malan, J. A., & Grainge, K. (2017) · Optics Letters · doi:10.1364/ol.42.001648 · Cited by 49
Stabilized Free-Space Optical Frequency Transfer
Gozzard, D. R., Schediwy, S., Stone, B., Messineo, M., & Tobar, M. E. (2018) · Physical Review Applied · doi:10.1103/physrevapplied.10.024046 · Cited by 54
“Over these atmospheric links, we achieved levels of fractional frequency stability, at integration times less than 64 s, comparable to the best achieved over optical fiber links of comparable length [5, 21], and exceeded the stability achieved by [12] and [38] using two-way time and frequency transfer of an optical co…”
BackgroundThe unit of time: Present and future directions
Bize, S. (2019) · Comptes Rendus Physique · doi:10.1016/j.crhy.2019.02.002 · Cited by 51
“om any place of interest on Earth. First proof-of-concept experiments used coherent optical fiber links between laboratories with already existing state-of-the-art optical frequency metrology programs [137][62]. Over the years, transportable optical frequency standards were developed and currently achieve uncertainties…”
BackgroundMethodInfluentialTesting gravity with cold-atom clocks in space: The ACES mission
Cacciapuoti, L., Armano, M., Much, R., Sy, O., Helm, A., Hess, M. P., Kehrer, J., Koller, S., Niedermaier, T., Esnault, F.-X., et al. (2020) · The European Physical Journal D · doi:10.1140/epjd/e2020-10167-7 · Cited by 48
Self-citationA null test of general relativity based on a long-term comparison of atomic transition frequencies
Ashby, N., Parker, T. E., & Patla, B. R. (2018) · Nature Physics · doi:10.1038/s41567-018-0156-2 · Cited by 53
Systematic evaluation of a 171Yb optical clock by synchronous comparison between two lattice systems
Gao, Q., Zhou, M., Han, C., Li, S., Zhang, S., Yao, Y., Li, B., Qiao, H., Ai, D., Lou, G., et al. (2018) · Scientific Reports · doi:10.1038/s41598-018-26365-w · Cited by 45
Terahertz Vibrational Molecular Clock with Systematic Uncertainty at the 10−14 Level
Leung, K. H., Iritani, B., Tiberi, E., Majewska, I., Borkowski, M., Moszyński, R., & Zelevinsky, T. (2023) · Physical Review X · doi:10.1103/physrevx.13.011047 · Cited by 42
Hybrid fiber links for accurate optical frequency comparison
Lee, W.-K., Stefani, F., Bercy, A., Lopez, O., Amy‐Klein, A., & Pottie, P.-É. (2017) · Applied Physics B · doi:10.1007/s00340-017-6736-5 · Cited by 38
“Optical fiber-based clock frequency comparison is not only useful for time–frequency metrology, but can also provide a powerful experimental tool in many applications, such as test of variation of fundamental constants [10], relativistic geodesy [6], and dark matter search [11].”
Self-citationSingle-ion, transportable optical atomic clocks
Delehaye, M., & Lacroûte, C. (2018) · Journal of Modern Optics · doi:10.1080/09500340.2018.1441917 · Cited by 54
On-line estimation of local oscillator noise and optimisation of servo parameters in atomic clocks
Leroux, I. D., Scharnhorst, N., Hannig, S., Kramer, J., Pelzer, L., Stepanova, M., & Schmidt, P. O. (2017) · Metrologia · doi:10.1088/1681-7575/aa66e9 · Cited by 50
Direct comparisons of European primary and secondary frequency standards via satellite techniques
Riedel, F., Al-Masoudi, A., Benkler, E., Dörscher, S., Gerginov, V, Grebing, C., Häfner, S., Huntemann, N., Lipphardt, B., Lisdat, C., et al. (2020) · Metrologia · doi:10.1088/1681-7575/ab6745 · Cited by 38
“0 × 10−16 49% 33% 98% 84% – 87% [20] [6] [4, 28] [4, 28]”
BackgroundInfluentialSelf-citationBouchand, R., Nicolodi, D., Xie, X., et al. (2017) · Optics Express · doi:10.1364/oe.25.012268 · Cited by 38
Self-citation13 134-Km Fiber-Optic Time Synchronization
Zuo, F., Xie, K., Hu, L., Chen, J., & Wu, G. (2021) · Journal of Lightwave Technology · doi:10.1109/jlt.2021.3102674 · Cited by 39
The permanent tide and the International Height Reference Frame IHRF
Mäkinen, J. (2021) · Journal of Geodesy · doi:10.1007/s00190-021-01541-5 · Cited by 45
“For geodesy, high accuracy in frequency comparisons at a distance are needed (Lisdat et al. 2016).”
BackgroundOhmae, N., Kuse, N., Fermann, M. E., & Katori, H. (2017) · Applied Physics Express · doi:10.7567/apex.10.062503 · Cited by 42
Wang, G., Pang, Z., Zhang, B., Wang, F., Chen, Y., Dai, H., Wang, B., & Wang, L. (2021) · Photonics Research · doi:10.1364/prj.443019 · Cited by 39
Gobron, O., Jung, K., Galland, N., Predehl, K., Targat, R. L., Ferrier, A., Goldner, P., Seidelin, S. L., & Coq, Y. L. (2017) · Optics Express · doi:10.1364/oe.25.015539 · Cited by 38
Probing Time Dilation in Coulomb Crystals in a High-Precision Ion Trap
Keller, J., Kalincev, D., Burgermeister, T., Kulosa, A. P., Didier, A., Nordmann, T., Kiethe, J., & Mehlstäubler, T. E. (2019) · Physical Review Applied · doi:10.1103/physrevapplied.11.011002 · Cited by 53
Ultra-broadband dual-branch optical frequency comb with 10 −18 instability
Rolland, A., Li, P., Kuse, N., Jiang, J., Cassinerio, M., Langrock, C., & Fermann, M. E. (2018) · Optica · doi:10.1364/optica.5.001070 · Cited by 39
SI-traceable frequency dissemination at 1572.06 nm in a stabilized fiber network with ring topology
Husmann, D., Bernier, L.-G., Bertrand, M., Calonico, D., Chaloulos, K. S., Clausen, G., Clivati, C., Faist, J., Heiri, E., Hollenstein, U., et al. (2021) · Optics Express · doi:10.1364/oe.427921 · Cited by 43
Votava, O., Kassi, S., Campargue, A., & Romanini, D. (2022) · Physical Chemistry Chemical Physics · doi:10.1039/d1cp04989e · Cited by 37
Golovizin, A. A., Tregubov, D. O., Fedorova, E. S., Mishin, D., Provorchenko, D. I., Khabarova, K. Y., Sorokin, V. N., & Kolachevsky, N. (2021) · Nature Communications · doi:10.1038/s41467-021-25396-8 · Cited by 34
Coherent Optical-Fiber Link Across Italy and France
Clivati, C., Pizzocaro, M., Bertacco, E. K., Condio, S., Costanzo, G. A., Donadello, S., Goti, I., Gozzelino, M., Levi, F., Mura, A., et al. (2022) · Physical Review Applied · doi:10.1103/physrevapplied.18.054009 · Cited by 43
Self-citationScharnhorst, N., Cerrillo, J., Kramer, J., Leroux, I. D., Wübbena, J. B., Retzker, A., & Schmidt, P. O. (2018) · Physical Review A · doi:10.1103/physreva.98.023424 · Cited by 36
Long-distance chronometric leveling with a portable optical clock
Grotti, J., Nosske, I., Koller, S. B., Herbers, S., Denker, H., Timmen, L., Vishnyakova, G., Grosche, G., Waterholter, T., Kuhl, A., et al. (2024) · Physical Review Applied · doi:10.1103/physrevapplied.21.l061001 · Cited by 33
“This leads to the concept of physical heights that are directly related to the geopotential (a physical quantity), in contrast to the purely geometrically defined el-lipsoidal heights (distance of a point from a given reference ellipsoid) from Global Navigation Satellite Systems (GNSS) measurements…”
Self-citationWicht, A., Bawamia, A., Krüger, M., Kürbis, C., Schiemangk, M., Smol, R., Peters, A., & Tränkle, G. (2017) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2253655 · Cited by 40
“Quantum optical sensors like atom interferometers [1], microwave [2][3] or optical atomic [4] clocks, or other implementations of precision spectroscopic methods find application in various fields ranging from inertial navigation [5][6][7] through geodesy, geophysics and exploration [8][9], time keeping [10], sensing…”
BackgroundFundamental constants: from measurement to the universe, a window on gravitation and cosmology
Uzan, J.-P. (2025) · Living Reviews in Relativity · doi:10.1007/s41114-025-00059-y · Cited by 36
Exploring potential applications of optical lattice clocks in a plate subduction zone
Tanaka, Y., & Katori, H. (2021) · Journal of Geodesy · doi:10.1007/s00190-021-01548-y · Cited by 31
“For example, continental-scale fiber links of optical clocks (Lisdat et al. 2016) are expected to unify height reference systems across countries, which improves accuracy and cost for geodetic leveling (Denker et al.”
BackgroundKoke, S., Kühl, A., Waterholter, T., Raupach, S. M. F., Lopez, O., Cantin, E., Quintin, N., Amy‐Klein, A., Pottie, P.-É., & Grosche, G. (2019) · New Journal of Physics · doi:10.1088/1367-2630/ab5d95 · Cited by 35
“June 2015 (parallel to the first international clock comparison campaign [8][16][32]); the second from 14.”
BackgroundMethodInfluentialSelf-citationPassive optical phase noise cancellation
Hu, L., Tian, X., Wu, G., & Chen, J. (2020) · Optics Letters · doi:10.1364/ol.393010 · Cited by 30
Entanglement-enhanced optical atomic clocks
Colombo, S., Pedrozo-Peñafiel, E., & Vuletić, V. (2022) · Applied Physics Letters · doi:10.1063/5.0121372 · Cited by 45
“22,23 Moreover, high timekeeping precision enables improvements in navigation systems, both GPS-based and inertial.”
BackgroundClock networks for height system unification: a simulation study
Wu, H., Müller, J., & Lämmerzahl, C. (2019) · Geophysical Journal International · doi:10.1093/gji/ggy508 · Cited by 30
Undifferenced and uncombined GNSS time and frequency transfer with integer ambiguity resolution
Mi, X., Zhang, B., El‐Mowafy, A., Wang, K., & Yuan, Y. (2023) · Journal of Geodesy · doi:10.1007/s00190-022-01689-8 · Cited by 33
Metadata
- Authors
- Lisdat, C., Grosche, G., Quintin, N., Shi, C., Raupach, S. M. F., Grebing, C., Nicolodi, D., Stefani, F., Al-Masoudi, A., Dörscher, S., Häfner, S., Robyr, J.-L., Chiodo, N., Bilicki, S., Bookjans, E., Koczwara, A., Koke, S., Kuhl, A., Wiotte, F., Meynadier, F., Camisard, E., Abgrall, M., Lours, M., Legero, T., Schnatz, H., Sterr, U., Denker, H., Chardonnet, C., Le Coq, Y., Santarelli, G., Amy-Klein, A., Le Targat, R., Lodewyck, J., Lopez, O., & Pottie, P.-E.
- Affiliations
- Physikalisch-Technische Bundesanstalt (DE)
- Centre National de la Recherche Scientifique (FR)
- Leibniz University Hannover (DE)
- Corresponding author
- Grosche, G.
- ORCID
- Venue
- Nature Communications
- Published
- 2016-08-09
- Volume
- 7
- Issue
- 1
- Pages
- 12443-12443
- ISSN
- 2041-1723 (ISSN-L)
- PMC
- PMC4980484
- OpenAlex
- W2233029113
- Semantic Scholar
- 0d0794a04d9b1159270897744230019a8f367c40
- Cited by
- 460
- References
- 53
- Citations by year
- 2026: 27 · 2025: 49 · 2024: 46 · 2023: 48 · 2022: 51 · 2021: 35 · 2020: 50 · 2019: 41 · 2018: 51 · 2017: 46 · 2016: 16
- FWCI
- 24.26
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by-sa
- creativecommons.org/licenses/by/4.0 (tdm)
- creativecommons.org/licenses/by/4.0 (vor)
- Locations
- Nature Communications (publishedVersion, cc-by-sa)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- arXiv (Cornell University) (submittedVersion)
- Institutional Repository of Leibniz Universität Hannover (Leibniz Universität Hannover) (submittedVersion, cc-by-nc-nd)
- HAL (submittedVersion, cc-by-nc)
- RePEc: Research Papers in Economics (submittedVersion)
- CINECA IRIS Institutial research information system (University of Pisa) (submittedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- arXiv (Cornell University)
- Leibniz Universität Hannover (cc-by)
- Funders
- European Association of National Metrology Institutes (SIB-02)
- Equipex
- European Commission
- Deutsche Forschungsgemeinschaft (CRC 1128 (“geo-Q”, RTG 1729, CRC 1128)
- Agence Nationale de la Recherche (Labex First-TF ANR-10-LABX-48-01, ANR 10 LABX 48 01, First-TF ANR-10-LABX-48-01, ANR blanc LIOM 2011-BS04-009-01, 009-01, 10-LABX-48-01, BS04-009-01, ANR-10-LABX-48, ANR-11-EQPX-0039, ANR-10, ANR-10-LABX, 2011-BS04-009-01)
- Centre National d’Etudes Spatiales
- Centre National de la Recherche Scientifique
- Leibniz-Gemeinschaft
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Frequency and Time Standards
- Physical Sciences › Computer Science › Computer Networks and Communications › Network Time Synchronization Technologies
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Quantum Information and Cryptography
- Keywords
- optical frequency transfer, clock distribution, geodesy, fundamental physics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
The claim verdicts this report counts are experimental: their accuracy is not yet measured.
A language model drew the claims from the paper on 2026-10-10, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-10 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (gpt-6-sol).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.