The DOI matches its Crossref record; 47 of the 53 references it cites were found in a registry or an index; 18 of the 22 sources its claims cite were checked for support.
A clock network for geodesy and fundamental science
Open accessAbstract
Leveraging the unrivalled performance of optical clocks as key tools for geo-science, for astronomy and for fundamental physics beyond the standard model requires comparing the frequency of distant optical clocks faithfully. Here, we report on the comparison and agreement of two strontium optical clocks at an uncertainty of 5 × 10(-17) via a newly established phase-coherent frequency link connecting Paris and Braunschweig using 1,415 km of telecom fibre. The remote comparison is limited only by the instability and uncertainty of the strontium lattice clocks themselves, with negligible contributions from the optical frequency transfer. A fractional precision of 3 × 10(-17) is reached after only 1,000 s averaging time, which is already 10 times better and more than four orders of magnitude faster than any previous long-distance clock comparison. The capability of performing high resolution international clock comparisons paves the way for a redefinition of the unit of time and an all-optical dissemination of the SI-second.
Overview
CoChat Summary
TL;DR
The paper demonstrates a direct all-optical comparison of two independent strontium lattice clocks in Paris and Braunschweig over 1,415 km of telecom fibre, achieving agreement at the 5 × 10−17 level. The fibre link contributes negligibly to the measurement, making the clock performance itself the limiting factor.
Key findings
- Two remote strontium optical clocks were compared with an uncertainty of 5 × 10−17 via a phase-coherent fibre link spanning 1,415 km of telecom fibre.
- A fractional precision of 3 × 10−17 was reached after 1,000 s averaging time, described as 10 times better and more than four orders of magnitude faster than any previous long-distance clock comparison.
- In the more extensive second campaign, the fractional offset between the clocks was (4.7 ± 5.0) × 10−17, with agreement within the combined uncertainties.
- The optical link’s fractional uncertainty was assessed as 2.5 × 10−19, and its instability averaged down faster than the clocks, so the remote comparison was limited by the clocks themselves.
Methods
- Two independent strontium optical lattice clocks were operated at LNE-SYRTE in Paris and PTB in Braunschweig; their frequencies were transferred to Strasbourg through stabilized fibre links and compared using femtosecond frequency combs.
- The study analyzed two measurement campaigns (March and June 2015) with 145 h of accumulated data; frequency ratios were corrected for systematic shifts, gravity-potential/redshift differences, and counter synchronization offsets.
- The main analysis combined local clock-to-transfer-laser comparisons, link-noise-cancelled fibre transfer, and Allan-deviation-based uncertainty evaluation for clock, link, and synchronization contributions.
Limitations
- The paper states that the comparison is limited by the instability and uncertainty of the strontium lattice clocks themselves, not by the optical transfer system.
- During the first campaign, counter gates in Paris and Strasbourg were accidentally not synchronized to UTC, requiring indirect reconstruction of the offset with an uncertainty of 10 ms; this is a stated experimental complication.
- Evident from the text: the results are for two clocks of the same species and under a specific fibre-network configuration, so the paper does not directly test broader clock types or fully general network conditions.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Figures



Verification
Claims the paper makes
8 Valid · 3 Not valid · 2 Not checked · 35 Own results and interpretations
The sources with a verdict support this claim; the rest weren’t checked yet, have no full text we could read, or their verdicts aren’t rated yet.
In the paper
“Our work not only enables the above mentioned applications, but also clears the path towards a redefinition of the unit of time, the SI second2425 through regular and practical international comparisons of optical clocks.”
§ A clock network for geodesy and fundamental science > Abstract
What the sources say
- Supportedcites [24] Riehle, F. Towards a redefinition of the second based on optical atomic clocks. C. R. Physique 16, 506–515 (2015). source
The Abstract (p. 1) identifies ways to compare remote optical clocks among the prerequisites for a future redefinition of the SI second. Section 4 (p. 12) discusses international clock comparisons and practical links for carrying them out. The citing authors’ statement that their own work ‘clears the path’ is their conclusion, not a finding attributed to Riehle. (LLM, conf=0.88)
- Not checked — no full text of the sourcecites [25] Margolis, H. Timekeepers of the future. Nat. Phys. 10, 82–83 (2014). source
boostedstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
Every source the paper cites for this claim was checked and supports it.
In the paper
“satellite link techniques do not reach significantly better performance either.”
§ A clock network for geodesy and fundamental science > Abstract
What the sources say
- Supportedcites [20] Hachisu, H. et al. Direct comparison of optical lattice clocks with an intercontinental baseline of 9000, km. Opt. Lett. 39, 4072–4075 (2014). source
On p. 3, the paper reports a 1.6 × 10⁻¹⁵ uncertainty for its satellite-linked clock comparison and gives 6 × 10⁻¹⁶ for a comparison using local Cs fountain clocks. Its p. 1 discussion also describes the performance limits of the GPSCP and TWCP satellite techniques. These passages support the claim that the satellite links did not deliver substantially better performance than the microwave-clock comparison discussed. (LLM, conf=0.84)
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“Complemented by phase-coherent telecom fibre links9101112 as extremely powerful tools for frequency dissemination on a continental scale”
§ A clock network for geodesy and fundamental science > Abstract
What the sources say
- Not checked — no full text of the sourcecites [9] Predehl, K. et al. A 920-Kilometer optical fiber link for frequency metrology at the 19th decimal place. Science 336, 441–444 (2012). source
- Supportedcites [10] Lopez, O. et al. Ultra-stable long distance optical frequency distribution using the Internet fiber network. Opt. Express 20, 23518–23526 (2012). source
The Introduction (p. 3) describes a phase-stabilized 540 km link on a public telecom network for disseminating ultra-stable optical signals and calls the approach scalable. It also discusses extending frequency distribution to a larger scale, supporting the claim about these links as tools for continental-scale dissemination. (LLM, conf=0.86)
- Partly supportedcites [11] Calosso, C. E. et al. Doppler-stabilized fiber link with 6 dB noise improvement below the classical limit. Opt. Lett. 40, 131–134 (2015). sourceExperimental — accuracy not yet measured
The passage labeled Abstract (p. 2) calls optical fiber links a key tool for frequency dissemination and describes coherent links using standard telecom fiber. But the reported experiment used a 47 km metropolitan link (Abstract, pp. 1, 3); our copy does not establish frequency dissemination on a continental scale. (LLM, conf=0.84)
boosted- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“The details of the actual implementation of state preparation and interrogation being quite different in the two experimental realizations of a Sr lattice clock5212223, systematic and statistical uncertainties are highly independent and uncorrelated.”
§ A clock network for geodesy and fundamental science > Results > Optical clock performance
What the sources say
- Partly supportedcites [5] Le Targat, R. et al. Experimental realization of an optical second with strontium lattice clocks. Nat. Commun. 4, 2109 (2013). sourceExperimental — accuracy not yet measured
The OLC architecture section says the two Sr clocks differ in key features, and the Figure 3 caption treats their combined systematic uncertainty as that of two uncorrelated clocks. Figure 1 describes independent probe feedback, but the paper does not establish that state preparation and interrogation are quite different or explicitly say that the clocks’ statistical uncertainties are uncorrelated. (LLM, conf=0.82)
- Could not verifycites [21] Falke, S. et al. A strontium lattice clock with 3 × 10−17 inaccuracy and its frequency. New J. Phys. 16, 073023 (2014). sourceExperimental — accuracy not yet measured
Section 2 describes the preparation and interrogation of this paper’s Sr clock, and section 5 compares its measured frequency with results from other laboratories. Neither passage describes differences between two Sr-clock implementations or says that their systematic and statistical uncertainties are independent or uncorrelated. Searches for those terms and the claimed comparison found no supporting passage. (LLM, conf=0.76)
- Could not verifycites [22] Grebing, C. et al. Realization of a time-scale with an optical clock. Optica 3, 563–569 (2016). sourceExperimental — accuracy not yet measured
Section II (p. 2) describes one Sr lattice clock operated in two campaigns, and the Supplementary Material (p. 7) describes its preparation and interrogation. The paper does not compare the implementations of two Sr clocks or say that their systematic and statistical uncertainties are uncorrelated; the independence mentioned in Data Analysis (p. 3) concerns two Cs fountain clocks. (LLM, conf=0.76)
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“This international all-optical clock measurement surpasses the accuracy of the best possible comparison achievable by measurements against primary caesium clocks by one order of magnitude5212223.”
§ A clock network for geodesy and fundamental science > Results > Campaigns to compare the strontium optical clocks
What the sources say
- Partly supportedcites [5] Le Targat, R. et al. Experimental realization of an optical second with strontium lattice clocks. Nat. Commun. 4, 2109 (2013). sourceExperimental — accuracy not yet measured
The Discussion (page unavailable) reports that a direct comparison of two strontium optical clocks achieved agreement better than three of the best caesium fountains could resolve. But the reported optical comparison uncertainty was 1.5 × 10⁻¹⁶ versus 3.1 × 10⁻¹⁶ for the caesium-based comparison—not an order of magnitude—and the Discussion describes comparisons between clocks at different institutes as future work, not this measurement. (LLM, conf=0.88)
- Partly supportedcites [21] Falke, S. et al. A strontium lattice clock with 3 × 10−17 inaccuracy and its frequency. New J. Phys. 16, 073023 (2014). sourceExperimental — accuracy not yet measured
The Introduction (page not available) says the best caesium fountain clocks limit absolute frequency measurements to about 2–4 × 10⁻¹⁶. Results and discussion (page not available) says direct optical-clock comparisons achieve smaller relative uncertainties, but does not quantify a tenfold advantage for an international all-optical measurement. This paper’s own absolute measurement used caesium fountains, so its nearly tenfold advantage refers to the strontium clock’s systematic uncertainty, not that measurement’s accuracy. (LLM, conf=0.85)
- Partly supportedcites [22] Grebing, C. et al. Realization of a time-scale with an optical clock. Optica 3, 563–569 (2016). sourceExperimental — accuracy not yet measured
Optical Clock Operation (p. 2) says the strontium clock’s systematic uncertainty is at least an order of magnitude below that of PTB’s primary caesium fountains. But this paper’s measurement compares a local strontium clock with caesium fountains; Data Analysis (p. 4) discusses agreement with measurements at other institutes, not the accuracy of the cited international all-optical measurement. (LLM, conf=0.86)
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
28 more claims · 1 with their cited sources checked
Create a free account to see all 48 claims and every source verdict.
- It may state two separate claims as one. 12
- Probably not a substantial claim. 3
- The quote only partly states this claim. 1
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Furthermore, the frequency of two atomic clocks can be compared via an interferometric fiber link (IFL), which supports sub-10 -19 accuracy over hundreds of kilometers [5-10].”
From Long-distance chronometric leveling with a portable optical clock (2024) · cites this paper as [6]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Phase compensated optical fiber links enable high accuracy atomic clocks separated by thousands of kilometers to be compared with unprecedented statistical resolution.”
From Test of Special Relativity Using a Fiber Network of Optical Clocks (2017) · cites this paper as [9]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“They reached the accuracy of 3×10 -17 using two Sr-lattice clocks with an uncertainty of 5×10 -17 between Paris and Braunschweig stations.”
From Time transfer and significance of vertical land motion in relativistic geodesy applications: a review paper (2023) · cites this paper as Lisdat et al. (2016)
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“A first attempt in this direction was the comparison of two strontium optical clocks between PTB and OBSPARIS via a fibre link, showing an uncertainty and agreement with the geodetic results of about 5 × 10 -17 (Lisdat et al. 2016).”
From Geodetic methods to determine the relativistic redshift at the level of 10 $$^{-18}$$ - 18 in the context of international timescales: a review and practical results (2018) · cites this paper as Lisdat et al. 2016
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Therefore, phase-coherent optical links have been developped using principally an optical fibre as a medium for the propagation [108, 109, 75, 74], attaining spectacular stability and accuracy in the range 10 -19 and below.”
From Chronometric Geodesy: Methods and Applications (2019) · cites this paper as [75]
Experimental — accuracy not yet measured
8 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Frequency Ratio of Al+and Hg+Single-Ion Optical Clocks; Metrology at the 17th Decimal Place
Rosenband, T., Hume, D. B., Schmidt, P. O., Chou, C. W., Brusch, A., Lorini, L., Oskay, W. H., Drullinger, R. E., Fortier, T. M., Stalnaker, J. E., et al. (2008) · Science · doi:10.1126/science.1154622 · Cited by 1,450
An optical lattice clock with accuracy and stability at the 10−18 level
Bloom, B. J., Nicholson, T. L., Williams, J. R., Campbell, S. L., Bishof, M., Zhang, X., Zhang, W., Bromley, S. L., & Ye, J. (2014) · Nature · doi:10.1038/nature12941 · Cited by 1,073
Nobel Lecture: Passion for precision
Hänsch, T. W. (2006) · Reviews of Modern Physics · doi:10.1103/revmodphys.78.1297 · Cited by 915
Frequency Comparison of Two High-Accuracy Al + Optical Clocks
Chou, C., Hume, D., Koelemeij, J., Wineland, D., & Rosenband, T. (2010) · Physical Review Letters · doi:10.1103/physrevlett.104.070802 · Cited by 903
Chou, C. W., Hume, D. B., Rosenband, T., & Wineland, D. J. (2010) · Science · doi:10.1126/science.1192720 · Cited by 828
An Atomic Clock with 10 –18 Instability
Hinkley, N., Sherman, J. A., Phillips, N. B., Schioppo, M., Lemke, N. D., Beloy, K., Pizzocaro, M., Oates, C. W., & Ludlow, A. D. (2013) · Science · doi:10.1126/science.1240420 · Cited by 817 · cited 1×
“Optical clocks are – due to their orders of magnitude better precision (1) and accuracy (2,3,4) than their microwave counterparts realizing the definition of the SI second – new sensors with highest resolving power to, e.”
BackgroundSystematic evaluation of an atomic clock at 2 × 10−18 total uncertainty
Nicholson, T. L., Campbell, S. L., Hutson, R. B., Marti, G. E., Bloom, B. J., McNally, R. L., Zhang, W., Barrett, M. D., Safronova, M. S., Strouse, G. F., et al. (2015) · Nature Communications · doi:10.1038/ncomms7896 · Cited by 780 · cited 1×
“Optical clocks are – due to their orders of magnitude better precision (1) and accuracy (2,3,4) than their microwave counterparts realizing the definition of the SI second – new sensors with highest resolving power to, e.”
BackgroundKómár, P., Kessler, E. M., Bishof, M., Jiang, L., Sørensen, A. S., Ye, J., & Lukin, M. D. (2014) · Nature Physics · doi:10.1038/nphys3000 · Cited by 768 · cited 1×
“Additionally, new geodetic reference frames based on relativistic geodesy (15,16) or a quantum network of clocks (17) can be established.”
BackgroundCryogenic optical lattice clocks
Ushijima, I., Takamoto, M., Das, M., Ohkubo, T., & Katori, H. (2015) · Nature Photonics · doi:10.1038/nphoton.2015.5 · Cited by 627 · cited 1×
“Optical clocks are – due to their orders of magnitude better precision (1) and accuracy (2,3,4) than their microwave counterparts realizing the definition of the SI second – new sensors with highest resolving power to, e.”
BackgroundNobel Lecture: Defining and measuring optical frequencies
Hall, J. L. (2006) · Reviews of Modern Physics · doi:10.1103/revmodphys.78.1279 · Cited by 614
Research works printed but not linked: 1
- Vermeer, M. Chronometric levelling, Reports of the Finnish Geodetic Institute 83, 2 (1983).
Cited by
Items 201–300 of 455
Characterization of AM-to-PM Conversion in Silicon p-i-n Photodiodes
Kang, L., & Kolner, B. H. (2019) · IEEE Photonics Technology Letters · doi:10.1109/lpt.2019.2914607 · Cited by 11
Real-time free-running time scale with remote clocks on fiber-based frequency network
Guo, Y. C., Wang, B., Wang, F. M., Shi, F. F., Zhang, A. M., Zhu, X., Yang, J., Feng, K. M., Han, C. H., Li, T. C., et al. (2019) · Metrologia · doi:10.1088/1681-7575/ab299d · Cited by 9
Polarization Effects on Thermally Stable Latency in Hollow-Core Photonic Bandgap Fibers
Fokoua, E. N., Zhu, W., Ding, M., et al. (2020) · Journal of Lightwave Technology · doi:10.1109/jlt.2020.3043832 · Cited by 9
“complex and costly engineering approaches such as bidirectional signal propagation and active fiber length stabilization [3], [7].”
BackgroundSalwik, K., Śliwczyński, Ł., Krehlik, P., & Kołodziej, J. (2021) · Optical Fiber Technology · doi:10.1016/j.yofte.2021.102465 · Cited by 9
Hoang, A. T., Shen, Z., Wu, K., Ning, A., & Shen, W. (2022) · Remote Sensing · doi:10.3390/rs14194850 · Cited by 10
Ultrastable laser referenced on velocity-grating atom interferometry
Shang, H., Pan, D., Zhang, X., Xue, X., Shi, T., & Chen, J. (2022) · Physical Review A · doi:10.1103/physreva.105.l051101 · Cited by 8
Lunar laser ranging with high-power continuous-wave lasers
Turyshev, S. G. (2025) · Physical Review Applied · doi:10.1103/hqtm-y5pg · Cited by 12
Wu, Y., & Shen, W. (2021) · Advances in Space Research · doi:10.1016/j.asr.2021.05.005 · Cited by 9
Coherent optical frequency transfer via 972-km fiber link
邓, X. 雪. D., 张, X. 翔. Z., 臧, Q. 琦. Z., 焦, D.-D. 东. J., 王, D. 丹. W., 刘, J. 杰. L., 高, J. 静. G., 许, G.-J. 冠. X., 董, R.-F. 瑞. D., 刘, T. 涛. L., et al. (2023) · Chinese Physics B · doi:10.1088/1674-1056/ad0629 · Cited by 8
Determination of the time-variable geopotential by means of orbiting clocks
Giuliani, S., Tapley, B. D., & Ries, J. (2024) · Journal of Geodesy · doi:10.1007/s00190-024-01868-9 · Cited by 9
Phase noise cancellation in polarisation-maintaining fibre links
Rauf, B., Lopez, M., Thoumany, P., Pizzocaro, M., & Calonico, D. (2018) · Review of Scientific Instruments · doi:10.1063/1.5016514 · Cited by 11
Strontium optical lattice clock
Yi-Ge, L., & Fang, Z. (2018) · Acta Physica Sinica · doi:10.7498/aps.67.20181097 · Cited by 8
Unidirectional two-way optical frequency comparison and its fundamental limitations
Xu, D., Lopez, O., Amy‐Klein, A., & Pottie, P.-É. (2020) · Optics Letters · doi:10.1364/ol.404866 · Cited by 8
Self-citationKadum, J. E., Ji, J., Kühl, A., Misera, M., Waterholter, T., & Koke, S. (2023) · APL Photonics · doi:10.1063/5.0133919 · Cited by 7
Self-citationMulti-Band and Multi-Service Open Optical Networks: Applications and Perspectives
Curri, V., & Calonico, D. (2020) · International Conference on Transparent Optical Networks · doi:10.1109/icton51198.2020.9203143 · Cited by 7
“Coherent optical fiber links demonstrated the best performances achievable in frequency dissemination [10], and they have been employed also for scientific applications such as geodesy and ra-dioastronomy among others [11, 12].”
BackgroundOpen-loop polarization mode dispersion mitigation for fibre-optic time and frequency transfer
Fordell, T. (2022) · Optics Express · doi:10.1364/oe.448553 · Cited by 9
Transfer of laser frequency from 729 nm to 1.5 µm with precision at the level of 10−20
Fang, P., Sun, H., Wang, Y., Xu, Y., & Chen, Q. (2022) · Chinese Optics Letters · doi:10.3788/col202220.081403 · Cited by 8
Lu, B., & Chang, H. (2022) · Chinese Physics B · doi:10.1088/1674-1056/ac90b0 · Cited by 8
Ultra-long-distance distribution of low-phase-noise reference lightwave for optical communications
Sakaguchi, J., Awaji, Y., & Furukawa, H. (2023) · Optics Express · doi:10.1364/oe.492367 · Cited by 8
Zhang, Y., Chen, Z., Yu, D., Niu, J., Chen, X., & Guo, H. M. (2023) · Review of Scientific Instruments · doi:10.1063/5.0157499 · Cited by 7
Wu, K., Shen, W., Sun, X. L., Cai, C., & Shen, Z. (2023) · Geo-spatial Information Science · doi:10.1080/10095020.2023.2231515 · Cited by 9
“Some successful clock-transportation experiments have been conducted for testing gravitational redshift or measuring geopotentials via fiber links (Grotti et al. 2018; Lisdat et al. 2016; Takamoto et al. 2020; Takano et al. 2016).”
A compact and robust cooling laser system for an optical strontium lattice clock
Schwarz, R., Dörscher, S., Al-Masoudi, A., Vogt, S., Li, Y., & Lisdat, C. (2019) · Review of Scientific Instruments · doi:10.1063/1.5063552 · Cited by 7
Self-citationAblewski, P., Bober, M., & Zawada, M. (2019) · Metrologia · doi:10.1088/1681-7575/ab63ae · Cited by 8
Piotrowski, M., Scarabel, J., Lobino, M., Streed, E. W., & Gensemer, S. D. (2020) · OSA Continuum · doi:10.1364/osac.396290 · Cited by 10
Qiu, Z., Li, R., Chen, W., Zhou, Z., Liu, J., Hu, L., Wu, G., & Chen, J. (2024) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2024.3460878 · Cited by 6
“T HE establishment of ultrastable and high-precision optical clock networks is crucial for a variety of applications, including navigation [1], gravitational sensing [2], precision spectroscopy [3], and fundamental physics experiments [4].”
BackgroundZhao, H., Xu, X., Li, W., Shi, H., Qian, Z., Sun, W., & Zhai, J. (2022) · Measurement · doi:10.1016/j.measurement.2022.111995 · Cited by 6
Integrated, reliable laser system for an 87Rb cold atom fountain clock
Zhang, Z., Xiang, J., Xu, B. S., et al. (2022) · Chinese Physics B · doi:10.1088/1674-1056/ac9e95 · Cited by 6
Investigation of proper time and inter-satellite clock difference using general relativity theory
Jia, Q., Li, Q., Liang, J. X., & Liu, L. (2022) · Aerospace Science and Technology · doi:10.1016/j.ast.2022.108071 · Cited by 6
Improving the Resolution of Comb-Based Frequency Measurements Using a Track-And-Hold Amplifier
Risaro, M., Savio, P., Pizzocaro, M., Levi, F., Calonico, D., & Clivati, C. (2022) · Physical Review Applied · doi:10.1103/physrevapplied.18.064010 · Cited by 8
“In our laboratory, the optical comb enables the spectral transfer between the sub-harmonic wavelengths of our (171)Yb and (88)Sr lattice clocks [25, 26] at 1156 nm and 1396 nm and a 1542 nm ultrastable radiation that is distributed between distant metrological institutes in Europe using optical fibers, to enable the c…”
BackgroundJürß, T., Grosche, G., & Koke, S. (2023) · Photonics Research · doi:10.1364/prj.485899 · Cited by 6
Self-citationNode-downloadable frequency transfer system based on a mode-locked laser with over 100 km of fiber
Jin, Z., Chen, Z., Wu, K. M., Yu, D., Wu, G., Song, Y., Luo, B., & Guo, H. M. (2023) · Optics Express · doi:10.1364/oe.505299 · Cited by 6
“Fiber-based time and frequency transfer has been widely demonstrated to be one of the mature technologies for long-distance time and frequency transfer[10–15, 18, 19, 25–27].”
BackgroundAn active method for coupling laser with a high-finesse Fabry–Pérot cavity in ultra-stable lasers
Meng, F., Li, Z., Li, J., Meng, L., Yin, X., Bian, W., Jia, J., & Wang, J. (2023) · Optics & Laser Technology · doi:10.1016/j.optlastec.2023.110371 · Cited by 6
Zalialiutdinov, T. A., Solovyev, D. A., Labzowsky, L. N., & Plunien, G. (2017) · Physical Review A · doi:10.1103/physreva.96.012512 · Cited by 6
Effect of a timebase mismatch in two-way optical frequency transfer
Tampellini, A., Clivati, C., Levi, F., Mura, A., & Calonico, D. (2017) · Metrologia · doi:10.1088/1681-7575/aa8a41 · Cited by 6
“In recent years, the transfer of optical frequencies via phasestabilized telecom fibers has proved to be the most performing technique to compare distant frequency standards, allowing uncertainties below the mid 10−19 level [1–4] and enabling remote comparisons of optical clocks over thousands of kilometers at their i…”
BackgroundHigh-precision multi-node clock network distribution
Chen, X., Cui, Y., Lu, X., Ci, C., Zhang, X., Liu, B., Wu, H., Tang, T., Shi, K., & Zhang, Z. (2017) · Review of Scientific Instruments · doi:10.1063/1.5006521 · Cited by 6
Schröder, S., Stellmer, S., & Kusche, J. (2021) · Geophysical Journal International · doi:10.1093/gji/ggab132 · Cited by 11
All-Passive Cascaded Optical Frequency Transfer
Zhang, X., Hu, L., Deng, X., Zang, Q., Liu, J., Jiao, D., Gao, J., Dong, R., Liu, T., Wu, G., et al. (2022) · IEEE Photonics Technology Letters · doi:10.1109/lpt.2022.3164406 · Cited by 7
Wave-front curvature in optical atomic beam clocks
Strathearn, A., Offer, R. F., Hilton, A. P., Klantsataya, E., Luiten, A. N., Anderson, R. P., Sparkes, B. M., & Stace, T. M. (2023) · Physical Review A · doi:10.1103/physreva.108.013105 · Cited by 5
Hoang, A. T., Shen, Z., & Shen, W. (2023) · IEEE Access · doi:10.1109/access.2023.3308519 · Cited by 7
“[13], [14], [15], [16], [17], [18], [19], [20].”
Ratchet loading and multi-ensemble operation in an optical lattice clock
Hassan, Y. S., Kobayashi, T., Bothwell, T., Siegel, J. L., Hunt, B. D., Beloy, K., Gibble, K., Grogan, T., & Ludlow, A. D. (2024) · Quantum Science and Technology · doi:10.1088/2058-9565/ad6286 · Cited by 6
“Their exceptional metrics have enabled novel applications beyond frequency metrology such as geodesy [6, 7], searches for dark matter [8–10], and tests of fundamental physics [11, 12].”
BackgroundTemperature-Induced Noise-Insensitive Laser Repeater Station for Optical Frequency Transfer
Qiu, Z., Zhou, Z., Hu, L., Liu, J., Wu, G., Chen, J., Zhang, X., Dong, R., Liu, T., & Zhang, S. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3561397 · Cited by 6
“Currently, high-performance optical clock networks are also widely used in time and frequency metrology [3], [4], radio astronomy [5], [6], gravitational-wave detection [7], and testing of fundamental physics [8].”
Zeng, T., Shen, Q., Cao, Y. W., Guan, J.-Y., Lian, M.-Z., Han, J.-J., Hou, L., Lu, J., Peng, X., Li, M., et al. (2024) · Photonics Research · doi:10.1364/prj.511141 · Cited by 5
REFIMEVE frequency and time network and applications
Cantin, E., Lopez, O., Chardonnet, C., Amy‐Klein, A., Rabault, M., Coget, G., Rosenbusch, P., Ménoret, V., Quintin, N., Tønnes, M., et al. (2024) · Journal of Physics Conference Series · doi:10.1088/1742-6596/2889/1/012031 · Cited by 7
Self-citationPast and Future of Optical Clocks Toward Redefinition of the SI Second
Ido, T. (2018) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2018.2874333 · Cited by 7
“Recent state-of-the-art optical clocks indicate the possibility that optical clocks may work as geodetic sensors [17], [18].”
BackgroundTowards precise one-way fiber-based frequency dissemination using phase-sensitive amplification
Bogris, A., Νίκας, Θ., & Slavı́k, R. (2019) · Optics Letters · doi:10.1364/ol.44.000550 · Cited by 5
Cai, Y., Zhang, T., Pan, R., et al. (2020) · IEEE photonics journal · doi:10.1109/jphot.2020.3010558 · Cited by 5
“powerful tools in the fields of low-phase-noise microwave generation [5], [6], comb-based spectroscopy [7], [8], high-precision laser detection and ranging [9], [10], and atomic clock networks [11], [12].”
MethodHoang, A. T., Shen, Z., Shen, W., Cai, C., Xu, W. S., Ning, A., & Wu, Y. (2021) · Geodesy and Geodynamics · doi:10.1016/j.geog.2021.08.003 · Cited by 6
Scientific Data Processing of a Fiber Network for Optical Frequency Transfer: Methods and Studies
Tønnes, M., Cantin, E., Xu, D., Lopez, O., Amy‐Klein, A., & Pottie, P.-É. (2021) · URSI Radio Science Letters · doi:10.46620/21-0011 · Cited by 4
“This makes it suitable for the comparison of optical clocks and cavities [1], very long baseline interferometry (VLBI) [2], spectroscopy [3], along with many other applications.”
BackgroundSelf-citationHigh‐stability optical frequency transfer with all‐fiber architecture for optical lattice clocks
Ohmae, N., Sakama, S., & Katori, H. (2019) · Electronics and Communications in Japan · doi:10.1002/ecj.12167 · Cited by 5
Multi-access fiber-optic time dissemination with bidirectional optical–electrical–optical nodes
Liu, Y., Wu, G., Zhang, H., Zuo, F., Hu, L., & Chen, J. (2020) · Review of Scientific Instruments · doi:10.1063/1.5134650 · Cited by 5
Improving the stability of real-time PPP solutions by receiver clock modeling
Mikoś, M., Kaźmierski, K., Schön, S., et al. (2026) · GPS Solutions · doi:10.1007/s10291-026-02048-2 · Cited by 4
“…realistic, as ultra-stable optical lattice clocks and cryogenic sapphire oscillators already demonstrate frequency stabilities superior to those of hydrogen masers and are being considered for applications in geodesy and time-transfer (Hartnett et al. 2012; Lisdat et al. 2016; Grotti et al. 2018).”
Narożnik, M., Bober, M., & Zawada, M. (2023) · Physics Letters B · doi:10.1016/j.physletb.2023.138260 · Cited by 5
Ren, J., Hu, L., Chen, J., & Wu, G. (2024) · Optics Express · doi:10.1364/oe.541349 · Cited by 4
Krehlik, P., Śliwczyński, Ł., Turza, K., Salwik, K., & Buczek, Ł. (2023) · Optics Express · doi:10.1364/oe.484923 · Cited by 4
Kalman filter framework for a regional mass change model from GRACE satellite gravity
Wöhnke, V., Eicker, A., Weigelt, M., Reich, M., Güntner, A., Kvas, A., & Mayer‐Gürr, T. (2024) · GEM - International Journal on Geomathematics · doi:10.1007/s13137-024-00260-1 · Cited by 4
“The principle is described, for example in Lisdat et al. (2016) and Müller et al. (2018).”
Hybrid fiber-based frequency dissemination and vibration sensing system
Li, W., Pang, Z., Dai, H., Li, C., & Wang, B. (2025) · Optics Letters · doi:10.1364/ol.551324 · Cited by 4
Lee, K. A., & Gunter, B. C. (2023) · Journal of Spacecraft and Rockets · doi:10.2514/1.a35515 · Cited by 4
Entanglement-enhanced synchronous differential comparison
Yu, D., Chen, J., & Zhang, S. (2023) · Physical Review A · doi:10.1103/physreva.107.043120 · Cited by 4
Microwave Frequency Dissemination over a 250 km Fiber Link with Stability at the 10−18 Level
Yu, S., Zhao, W., Xue, W., & Zhang, S. (2023) · Photonics · doi:10.3390/photonics10080872 · Cited by 4
Time and Frequency Metrology in the Context of Relativistic Geodesy
Bauch, A. (2019) · Fundamental theories of physics · doi:10.1007/978-3-030-11500-5_1 · Cited by 5
An active optical frequency reference using a pulsed superradiant laser
Silva, J. M., Cline, J., Thompson, J. K., & Norcia, M. A. (2019) · Optical and Quantum Sensing and Precision Metrology II · doi:10.1117/12.2515582 · Cited by 4
Direct phase-locking of a Ti:Sapphire optical frequency comb to a remote optical frequency standard
Chae, E., Nakashima, K., Ikeda, T., Sugiyama, K., & Yoshioka, K. (2019) · Optics Express · doi:10.1364/oe.27.015649 · Cited by 5
A strontium optical lattice clock apparatus for precise frequency metrology and beyond
Tarallo, M. G., Calonico, D., Levi, F., Barbiero, M., Lamporesi, G., & Ferrari, G. (2017) · Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS) · doi:10.1109/fcs.2017.8089020 · Cited by 4
“Frequency comparisons of Sr clocks have been already used to constrain gravitational theories [2] and are foreseen to be used in relativistic geodesy [3].”
MethodZhicheng, 金. J., Shenhui, 薛. X., Zhiyuan, 徐. X., Fei, 杨. Y., Kang, 应. Y., & Youzhen, 桂. G. (2024) · Chinese Journal of Lasers · doi:10.3788/cjl240642 · Cited by 3
Ishiyama, T., Ono, K., Kawase, H., Takano, T., Asano, R., Sunaga, A., Yamamoto, Y., Tanaka, M., & Takahashi, Y. (2026) · Nature Photonics · doi:10.1038/s41566-026-01857-8 · Cited by 10
“Accuracy of optical clocks has been improved dramatically and is now reaching the 10 − 19 level [1], enabling the redefinition of the second [2] and various applications such as geodesy [3, 4] and new physics searches [5].”
Tanaka, Y., & Aoki, Y. (2022) · International Association of Geodesy symposia · doi:10.1007/1345_2022_147 · Cited by 3
Two-Way Single-Photon Laser Time Transfer for High-Speed Moving Platforms
Zhu, X., Wang, Y., Li, Z., Li, X., & Wu, G. (2024) · Photonics · doi:10.3390/photonics11111028 · Cited by 3
Liu, Q., Gao, H., Dong, J., Wang, Z., Yu, S., & Luo, B. (2024) · Optics Letters · doi:10.1364/ol.537502 · Cited by 3
Quantum sensing using atomic clocks for nuclear and particle physics
Kawasaki, A. (2025) · Applied Physics Reviews · doi:10.1063/5.0273813 · Cited by 10
Temperature-dependent mechanical losses of Eu3+:Y2SiO5 for spectral hole burning laser stabilization
Wagner, N., Hartman, M. T., Fang, B., Dickmann, J., & Kroker, S. (2025) · APL Materials · doi:10.1063/5.0258703 · Cited by 4
Trapped-ion optical Atomic Clocks at the Quantum Limits
Leibrandt, D. R., Brewer, S. M., Chen, J.-S., Chou, C. W., Hankin, A. M., Hume, D. B., & Wineland, D. J. (2017) · Proceedings of the ... annual Precise Time and Time Interval (PTTI) Systems and Applications Meeting/Proceedings of a meeting - Precise Time and Time Interval (PTTI) Systems and Applications Meeting · doi:10.33012/2017.15003 · Cited by 3
“In addition to the possibility of a redefinition of the SI second based on optical atomic clocks [7], optical clocks may also find applications ranging from advanced navigation systems and relativistic geodesy to tests of fundamental physics [8, 9].”
BackgroundGround-to-satellite time and frequency synchronization link with active carrier phase compensation
Sun, S., Bai, Y., Liang, H. J., Wang, S., & Wang, L. (2019) · Review of Scientific Instruments · doi:10.1063/1.5086362 · Cited by 3
REFIMEVE Fiber Network for Time and Frequency Dissemination and Applications
Cantin, E., Lopez, O., Cahuzac, N., Liu, Y., Manceau, M., Darquié, B., Chardonnet, C., Amy‐Klein, A., Quintin, N., Rabault, M., et al. (2023) · Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS) · doi:10.1109/eftf/ifcs57587.2023.10272084 · Cited by 6
“It is also very interesting for applications to chronometric geodesy, using these clocks comparison campaigns [9] or with the planned development of a mobile platform which can be placed at the output end of any links providing transportable comb and clock for clock comparisons.”
Self-citationSearching for scalar ultralight dark matter via refractive index changes in fibers
Manley, J. P., Stump, R., Petery, R. B., & Singh, S. (2023) · Physical review. D/Physical review. D. · doi:10.1103/physrevd.108.075008 · Cited by 3
Free space optical link to a tethered balloon for frequency transfer and chronometric geodesy
Maron, N. G. J., Fernandez, S., Esnault, F.-X., Lévèque, T., Muzeau, T., & Wolf, P. (2024) · Optics Express · doi:10.1364/oe.511244 · Cited by 3
Analysis and Reduction of Nonlinear Effects in Optical Fiber Frequency Transfer
Gao, J., Zhang, L., Jiao, D., Xu, G., Bu, J., Wu, M., Zang, Q., Zhang, X., Dong, R., Liu, T., et al. (2023) · Applied Sciences · doi:10.3390/app132312762 · Cited by 4
Xie, K., Hu, L., Chen, J., & Wu, G. (2024) · Science China Information Sciences · doi:10.1007/s11432-024-4058-9 · Cited by 3
“Moreover, OFT can perform a comparison between state-of-the-art optical atomic clocks and implement coherent optical phase transfer over long distances to support geodesy [1,3].”
BackgroundRemote Comparison of Two Sr Optical Lattice Clocks through a 58 km Fiber Link
廖, T.-Y. 堂. L., 刘, H. 豪. L., Meng, F., Wang, Q., Yang, T., Tian, H., Lu, B.-K., Zhu, L., Li, Y., Lin, B., et al. (2025) · Chinese Physics Letters · doi:10.1088/0256-307x/42/3/034201 · Cited by 4
REFIMEVE+: Optical Frequency Dissemination Over 2x1300 km of a Telecom Network
Cantin, E., Lopez, O., Amy‐Klein, A., Chardonnet, C., Cantin, E., Tønnes, M., Meynadier, F., Pottie, P.-É., Quintin, N., Camisard, É., et al. (2019) · Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS) · doi:10.1109/fcs.2019.8856085 · Cited by 3
Self-citationAnalysis of non-tidal ocean loading for gravitational potential observations in northern Europe
Leßmann, L., & Müller, J. (2018) · Journal of Geodynamics · doi:10.1016/j.jog.2018.05.008 · Cited by 5
Bilicki, S. (2017) · theses.fr (ABES) · doi:10.70675/4b3e81f4z8872z4d16z8156z517133a256ac · Cited by 9
“Nowadays, the best Yb+ ion clock at PTB can reach an accuracy of 3× 10−18 in fractional units [41].”
BackgroundMethodInfluentialSelf-citationBagherbandi, M., Shirazian, M., Amin, H., & Horemuz, M. (2023) · Frontiers in Earth Science · doi:10.3389/feart.2023.1139211 · Cited by 2
“Currently, there are some optical clock network projects, such as Paris and Braunschweig’s network based on using 1,415 km of telecom fiber (Lisdat et al., 2016) of which the accuracy is studied by Lisdat et al.”
BackgroundXiong, C., Liu, D., Wu, L., Bao, L., & Zhang, P. (2022) · Remote Sensing · doi:10.3390/rs14174141 · Cited by 3
ELT: An Optical Time Transfer Method Based on SLR and One-Way Ranging
Schlicht, A., Marz, S., Kodet, J., et al. (2026) · International Association of Geodesy symposia · doi:10.1007/1345_2026_330 · Cited by 2
Zalialiutdinov, T. A., Solovyev, D. A., & Labzowsky, L. N. (2018) · Journal of Experimental and Theoretical Physics · doi:10.1134/s1063776118010119 · Cited by 2
Liang, H.-J., Wang, S., Bai, Y., Sun, S., & Wang, L. (2021) · Chinese Physics B · doi:10.1088/1674-1056/ac05a6 · Cited by 5
Witkowski, M., Bilicki, S., Bober, M., Kovačić, D., Singh, V., Tonoyan, A., & Zawada, M. (2022) · Optics Express · doi:10.1364/oe.460554 · Cited by 5
Self-citationLaser cooling of thulium atoms to ground vibrational state in an optical lattice
Provorchenko, D. I., Tregubov, D. O., Golovizin, A. A., & Kolachevsky, N. (2024) · Physics-Uspekhi · doi:10.3367/ufne.2024.05.039678 · Cited by 4
A Tampering Risk of Fiber-Based Frequency Synchronization Networks
Dai, H., Chen, Y., Li, W., Wang, F., Wang, G., Pang, Z., & Wang, B. (2024) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2024.3414551 · Cited by 2
“The related instruments have been successfully applied in various fields, such as metrology [6], [8], [13], communication [14], navigation [15], and radio astronomy [16], [17], as shown in Fig.”
BackgroundMethodOptical frequency transfer link with remote site compensation
Zang, Q., Zhang, X., Deng, X., Zhou, Q., Wang, D., Zhang, Y., Gao, J., Jiao, D., Xu, G., Liu, T., et al. (2024) · Chinese Optics Letters · doi:10.3788/col202422.090601 · Cited by 2
Optical-Comb-Based Frequency Stability Transfer Across the Spectrum With a Multichannel FPGA
Savio, P., Goti, I., Pizzocaro, M., Levi, F., Calonico, D., & Clivati, C. (2025) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2025.3526761 · Cited by 4
“…the generation of advanced timescales [6], [7], [8], [9] in the frame of the forthcoming redefinition of the second [10], [11], chronometric leveling with cm-level resolution [12], [13], [14], [15], and advanced tests of fundamental physics both at local [16], [17] or distributed scale [18].”
Advances in time-frequency based geopotential determination
Sun, H., Shen, W., Gao, K., Gao, Y., Hou, M., Bao, L., Zhang, P., & Shen, Z. (2025) · Geodesy and Geodynamics · doi:10.1016/j.geog.2025.04.002 · Cited by 4
Liu, L., Cheng, N., Wang, J., Cao, Q., Tong, Z., Kang, Y. B., & Gui, Y. (2022) · IEEE photonics journal · doi:10.1109/jphot.2022.3191320 · Cited by 2
Tausendmal genauer: Optische Atomuhren
Tamm, C., & Peik, E. (2017) · Physik in unserer Zeit · doi:10.1002/piuz.201701470 · Cited by 2
Earthquakes detection with optical fibers
Clivati, C., Baptie, B. J., Xuereb, A., Mura, A., Levi, F., Calonico, D., Marra, G., Kronjäger, J., Wright, L., Robinson, S. P., et al. (2019) · Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS) · doi:10.1109/fcs.2019.8855993 · Cited by 3
“Our approach is based on coherent transmission of a continuous wave, narrow-linewidth laser and on heterodyne detection [2], and it is based on techniques developed for the dissemination of ultra-stable frequencies over optical fiber [3-5].”
MethodThe path to continuous Bose-Einstein condensation
Chen, C.-C., Bennetts, S., & Schreck, F. (2023) · Advances in atomic, molecular, and optical physics · doi:10.1016/bs.aamop.2023.04.004 · Cited by 2
Shaoshao, 鱼. Y., Honglei, 全. Q., Wenyu, 赵. Z., Wenxiang, 薛. X., Xin, 王. W., & Zhang, S. (2024) · Acta Optica Sinica · doi:10.3788/aos231680 · Cited by 2
Hoghooghi, N., Mazur, M., Fontaine, N. K., Liu, Y., Hayashi, T., Sciullo, G. D., Shaji, D. A., Mecozzi, A., Antonelli, C., & Quinlan, F. (2024) · Optical Fiber Communication Conference · doi:10.1364/ofc.2024.th4a.5 · Cited by 2
Laser cooling of thulium atoms to ground vibrational state in an optical lattice
Provorchenko, D. I., Tregubov, D. O., Golovizin, A. A., & Kolachevsky, N. (2024) · Uspekhi Fizicheskih Nauk · doi:10.3367/ufnr.2024.05.039678 · Cited by 2
Study of Accuracy and Stability of Sr Lattice Clocks at LNE-SYRTE
Vallet, G., Bilicki, S., Targat, R. L., & Lodewyck, J. (2018) · Conference on Precision Electromagnetic Measurements · doi:10.1109/cpem.2018.8500833 · Cited by 2
“The two clocks are able to operate quasi-autonomously over extended periods of time of several weeks, facilitating their use for international clock comparisons [1] or tests of fundamental physics [2].”
BackgroundSelf-citation
Metadata
- Authors
- Lisdat, C., Grosche, G., Quintin, N., Shi, C., Raupach, S. M. F., Grebing, C., Nicolodi, D., Stefani, F., Al-Masoudi, A., Dörscher, S., Häfner, S., Robyr, J.-L., Chiodo, N., Bilicki, S., Bookjans, E., Koczwara, A., Koke, S., Kuhl, A., Wiotte, F., Meynadier, F., Camisard, E., Abgrall, M., Lours, M., Legero, T., Schnatz, H., Sterr, U., Denker, H., Chardonnet, C., Le Coq, Y., Santarelli, G., Amy-Klein, A., Le Targat, R., Lodewyck, J., Lopez, O., & Pottie, P.-E.
- Affiliations
- Physikalisch-Technische Bundesanstalt (DE)
- Centre National de la Recherche Scientifique (FR)
- Leibniz University Hannover (DE)
- Corresponding author
- Grosche, G.
- ORCID
- Venue
- Nature Communications
- Published
- 2016-08-09
- Volume
- 7
- Issue
- 1
- Pages
- 12443-12443
- ISSN
- 2041-1723 (ISSN-L)
- PMC
- PMC4980484
- OpenAlex
- W2233029113
- Semantic Scholar
- 0d0794a04d9b1159270897744230019a8f367c40
- Cited by
- 460
- References
- 53
- Citations by year
- 2026: 27 · 2025: 49 · 2024: 46 · 2023: 48 · 2022: 51 · 2021: 35 · 2020: 50 · 2019: 41 · 2018: 51 · 2017: 46 · 2016: 16
- FWCI
- 24.26
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by-sa
- creativecommons.org/licenses/by/4.0 (tdm)
- creativecommons.org/licenses/by/4.0 (vor)
- Locations
- Nature Communications (publishedVersion, cc-by-sa)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- arXiv (Cornell University) (submittedVersion)
- Institutional Repository of Leibniz Universität Hannover (Leibniz Universität Hannover) (submittedVersion, cc-by-nc-nd)
- HAL (submittedVersion, cc-by-nc)
- RePEc: Research Papers in Economics (submittedVersion)
- CINECA IRIS Institutial research information system (University of Pisa) (submittedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- arXiv (Cornell University)
- Leibniz Universität Hannover (cc-by)
- Funders
- European Association of National Metrology Institutes (SIB-02)
- Equipex
- European Commission
- Deutsche Forschungsgemeinschaft (CRC 1128 (“geo-Q”, RTG 1729, CRC 1128)
- Agence Nationale de la Recherche (Labex First-TF ANR-10-LABX-48-01, ANR 10 LABX 48 01, First-TF ANR-10-LABX-48-01, ANR blanc LIOM 2011-BS04-009-01, 009-01, 10-LABX-48-01, BS04-009-01, ANR-10-LABX-48, ANR-11-EQPX-0039, ANR-10, ANR-10-LABX, 2011-BS04-009-01)
- Centre National d’Etudes Spatiales
- Centre National de la Recherche Scientifique
- Leibniz-Gemeinschaft
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Frequency and Time Standards
- Physical Sciences › Computer Science › Computer Networks and Communications › Network Time Synchronization Technologies
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Quantum Information and Cryptography
- Keywords
- optical frequency transfer, clock distribution, geodesy, fundamental physics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
The claim verdicts this report counts are experimental: their accuracy is not yet measured.
A language model drew the claims from the paper on 2026-10-10, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-10 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (gpt-6-sol).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.