A clock network for geodesy and fundamental science
Open accessThe DOI matches its Crossref record; 47 of the 53 references it cites were found in a registry or an index; 18 of the 22 sources its claims cite were checked for support.
Abstract
Leveraging the unrivalled performance of optical clocks as key tools for geo-science, for astronomy and for fundamental physics beyond the standard model requires comparing the frequency of distant optical clocks faithfully. Here, we report on the comparison and agreement of two strontium optical clocks at an uncertainty of 5 × 10(-17) via a newly established phase-coherent frequency link connecting Paris and Braunschweig using 1,415 km of telecom fibre. The remote comparison is limited only by the instability and uncertainty of the strontium lattice clocks themselves, with negligible contributions from the optical frequency transfer. A fractional precision of 3 × 10(-17) is reached after only 1,000 s averaging time, which is already 10 times better and more than four orders of magnitude faster than any previous long-distance clock comparison. The capability of performing high resolution international clock comparisons paves the way for a redefinition of the unit of time and an all-optical dissemination of the SI-second.
Overview
CoChat Summary
TL;DR
The paper demonstrates a direct all-optical comparison of two independent strontium lattice clocks in Paris and Braunschweig over 1,415 km of telecom fibre, achieving agreement at the 5 × 10−17 level. The fibre link contributes negligibly to the measurement, making the clock performance itself the limiting factor.
Key findings
- Two remote strontium optical clocks were compared with an uncertainty of 5 × 10−17 via a phase-coherent fibre link spanning 1,415 km of telecom fibre.
- A fractional precision of 3 × 10−17 was reached after 1,000 s averaging time, described as 10 times better and more than four orders of magnitude faster than any previous long-distance clock comparison.
- In the more extensive second campaign, the fractional offset between the clocks was (4.7 ± 5.0) × 10−17, with agreement within the combined uncertainties.
- The optical link’s fractional uncertainty was assessed as 2.5 × 10−19, and its instability averaged down faster than the clocks, so the remote comparison was limited by the clocks themselves.
Methods
- Two independent strontium optical lattice clocks were operated at LNE-SYRTE in Paris and PTB in Braunschweig; their frequencies were transferred to Strasbourg through stabilized fibre links and compared using femtosecond frequency combs.
- The study analyzed two measurement campaigns (March and June 2015) with 145 h of accumulated data; frequency ratios were corrected for systematic shifts, gravity-potential/redshift differences, and counter synchronization offsets.
- The main analysis combined local clock-to-transfer-laser comparisons, link-noise-cancelled fibre transfer, and Allan-deviation-based uncertainty evaluation for clock, link, and synchronization contributions.
Limitations
- The paper states that the comparison is limited by the instability and uncertainty of the strontium lattice clocks themselves, not by the optical transfer system.
- During the first campaign, counter gates in Paris and Strasbourg were accidentally not synchronized to UTC, requiring indirect reconstruction of the offset with an uncertainty of 10 ms; this is a stated experimental complication.
- Evident from the text: the results are for two clocks of the same species and under a specific fibre-network configuration, so the paper does not directly test broader clock types or fully general network conditions.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Figures



Verification
Claims the paper makes
8 Valid · 3 Not valid · 2 Not checked · 35 Own results and interpretations
The sources with a verdict support this claim; the rest weren’t checked yet, have no full text we could read, or their verdicts aren’t rated yet.
In the paper
“Our work not only enables the above mentioned applications, but also clears the path towards a redefinition of the unit of time, the SI second2425 through regular and practical international comparisons of optical clocks.”
§ A clock network for geodesy and fundamental science > Abstract
What the sources say
- Supportedcites [24] Riehle, F. Towards a redefinition of the second based on optical atomic clocks. C. R. Physique 16, 506–515 (2015). source
The Abstract (p. 1) identifies ways to compare remote optical clocks among the prerequisites for a future redefinition of the SI second. Section 4 (p. 12) discusses international clock comparisons and practical links for carrying them out. The citing authors’ statement that their own work ‘clears the path’ is their conclusion, not a finding attributed to Riehle. (LLM, conf=0.88)
- Not checked — no full text of the sourcecites [25] Margolis, H. Timekeepers of the future. Nat. Phys. 10, 82–83 (2014). source
boostedstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
Every source the paper cites for this claim was checked and supports it.
In the paper
“satellite link techniques do not reach significantly better performance either.”
§ A clock network for geodesy and fundamental science > Abstract
What the sources say
- Supportedcites [20] Hachisu, H. et al. Direct comparison of optical lattice clocks with an intercontinental baseline of 9000, km. Opt. Lett. 39, 4072–4075 (2014). source
On p. 3, the paper reports a 1.6 × 10⁻¹⁵ uncertainty for its satellite-linked clock comparison and gives 6 × 10⁻¹⁶ for a comparison using local Cs fountain clocks. Its p. 1 discussion also describes the performance limits of the GPSCP and TWCP satellite techniques. These passages support the claim that the satellite links did not deliver substantially better performance than the microwave-clock comparison discussed. (LLM, conf=0.84)
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“Complemented by phase-coherent telecom fibre links9101112 as extremely powerful tools for frequency dissemination on a continental scale”
§ A clock network for geodesy and fundamental science > Abstract
What the sources say
- Not checked — no full text of the sourcecites [9] Predehl, K. et al. A 920-Kilometer optical fiber link for frequency metrology at the 19th decimal place. Science 336, 441–444 (2012). source
- Supportedcites [10] Lopez, O. et al. Ultra-stable long distance optical frequency distribution using the Internet fiber network. Opt. Express 20, 23518–23526 (2012). source
The Introduction (p. 3) describes a phase-stabilized 540 km link on a public telecom network for disseminating ultra-stable optical signals and calls the approach scalable. It also discusses extending frequency distribution to a larger scale, supporting the claim about these links as tools for continental-scale dissemination. (LLM, conf=0.86)
- Partly supportedcites [11] Calosso, C. E. et al. Doppler-stabilized fiber link with 6 dB noise improvement below the classical limit. Opt. Lett. 40, 131–134 (2015). sourceExperimental — accuracy not yet measured
The passage labeled Abstract (p. 2) calls optical fiber links a key tool for frequency dissemination and describes coherent links using standard telecom fiber. But the reported experiment used a 47 km metropolitan link (Abstract, pp. 1, 3); our copy does not establish frequency dissemination on a continental scale. (LLM, conf=0.84)
boosted- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“The details of the actual implementation of state preparation and interrogation being quite different in the two experimental realizations of a Sr lattice clock5212223, systematic and statistical uncertainties are highly independent and uncorrelated.”
§ A clock network for geodesy and fundamental science > Results > Optical clock performance
What the sources say
- Partly supportedcites [5] Le Targat, R. et al. Experimental realization of an optical second with strontium lattice clocks. Nat. Commun. 4, 2109 (2013). sourceExperimental — accuracy not yet measured
The OLC architecture section says the two Sr clocks differ in key features, and the Figure 3 caption treats their combined systematic uncertainty as that of two uncorrelated clocks. Figure 1 describes independent probe feedback, but the paper does not establish that state preparation and interrogation are quite different or explicitly say that the clocks’ statistical uncertainties are uncorrelated. (LLM, conf=0.82)
- Could not verifycites [21] Falke, S. et al. A strontium lattice clock with 3 × 10−17 inaccuracy and its frequency. New J. Phys. 16, 073023 (2014). sourceExperimental — accuracy not yet measured
Section 2 describes the preparation and interrogation of this paper’s Sr clock, and section 5 compares its measured frequency with results from other laboratories. Neither passage describes differences between two Sr-clock implementations or says that their systematic and statistical uncertainties are independent or uncorrelated. Searches for those terms and the claimed comparison found no supporting passage. (LLM, conf=0.76)
- Could not verifycites [22] Grebing, C. et al. Realization of a time-scale with an optical clock. Optica 3, 563–569 (2016). sourceExperimental — accuracy not yet measured
Section II (p. 2) describes one Sr lattice clock operated in two campaigns, and the Supplementary Material (p. 7) describes its preparation and interrogation. The paper does not compare the implementations of two Sr clocks or say that their systematic and statistical uncertainties are uncorrelated; the independence mentioned in Data Analysis (p. 3) concerns two Cs fountain clocks. (LLM, conf=0.76)
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“This international all-optical clock measurement surpasses the accuracy of the best possible comparison achievable by measurements against primary caesium clocks by one order of magnitude5212223.”
§ A clock network for geodesy and fundamental science > Results > Campaigns to compare the strontium optical clocks
What the sources say
- Partly supportedcites [5] Le Targat, R. et al. Experimental realization of an optical second with strontium lattice clocks. Nat. Commun. 4, 2109 (2013). sourceExperimental — accuracy not yet measured
The Discussion (page unavailable) reports that a direct comparison of two strontium optical clocks achieved agreement better than three of the best caesium fountains could resolve. But the reported optical comparison uncertainty was 1.5 × 10⁻¹⁶ versus 3.1 × 10⁻¹⁶ for the caesium-based comparison—not an order of magnitude—and the Discussion describes comparisons between clocks at different institutes as future work, not this measurement. (LLM, conf=0.88)
- Partly supportedcites [21] Falke, S. et al. A strontium lattice clock with 3 × 10−17 inaccuracy and its frequency. New J. Phys. 16, 073023 (2014). sourceExperimental — accuracy not yet measured
The Introduction (page not available) says the best caesium fountain clocks limit absolute frequency measurements to about 2–4 × 10⁻¹⁶. Results and discussion (page not available) says direct optical-clock comparisons achieve smaller relative uncertainties, but does not quantify a tenfold advantage for an international all-optical measurement. This paper’s own absolute measurement used caesium fountains, so its nearly tenfold advantage refers to the strontium clock’s systematic uncertainty, not that measurement’s accuracy. (LLM, conf=0.85)
- Partly supportedcites [22] Grebing, C. et al. Realization of a time-scale with an optical clock. Optica 3, 563–569 (2016). sourceExperimental — accuracy not yet measured
Optical Clock Operation (p. 2) says the strontium clock’s systematic uncertainty is at least an order of magnitude below that of PTB’s primary caesium fountains. But this paper’s measurement compares a local strontium clock with caesium fountains; Data Analysis (p. 4) discusses agreement with measurements at other institutes, not the accuracy of the cited international all-optical measurement. (LLM, conf=0.86)
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
28 more claims · 1 with their cited sources checked
Create a free account to see all 48 claims and every source verdict.
- It may state two separate claims as one. 12
- Probably not a substantial claim. 3
- The quote only partly states this claim. 1
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Furthermore, the frequency of two atomic clocks can be compared via an interferometric fiber link (IFL), which supports sub-10 -19 accuracy over hundreds of kilometers [5-10].”
From Long-distance chronometric leveling with a portable optical clock (2024) · cites this paper as [6]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Phase compensated optical fiber links enable high accuracy atomic clocks separated by thousands of kilometers to be compared with unprecedented statistical resolution.”
From Test of Special Relativity Using a Fiber Network of Optical Clocks (2017) · cites this paper as [9]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“They reached the accuracy of 3×10 -17 using two Sr-lattice clocks with an uncertainty of 5×10 -17 between Paris and Braunschweig stations.”
From Time transfer and significance of vertical land motion in relativistic geodesy applications: a review paper (2023) · cites this paper as Lisdat et al. (2016)
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“A first attempt in this direction was the comparison of two strontium optical clocks between PTB and OBSPARIS via a fibre link, showing an uncertainty and agreement with the geodetic results of about 5 × 10 -17 (Lisdat et al. 2016).”
From Geodetic methods to determine the relativistic redshift at the level of 10 $$^{-18}$$ - 18 in the context of international timescales: a review and practical results (2018) · cites this paper as Lisdat et al. 2016
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Therefore, phase-coherent optical links have been developped using principally an optical fibre as a medium for the propagation [108, 109, 75, 74], attaining spectacular stability and accuracy in the range 10 -19 and below.”
From Chronometric Geodesy: Methods and Applications (2019) · cites this paper as [75]
Experimental — accuracy not yet measured
8 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Frequency Ratio of Al+and Hg+Single-Ion Optical Clocks; Metrology at the 17th Decimal Place
Rosenband, T., Hume, D. B., Schmidt, P. O., Chou, C. W., Brusch, A., Lorini, L., Oskay, W. H., Drullinger, R. E., Fortier, T. M., Stalnaker, J. E., et al. (2008) · Science · doi:10.1126/science.1154622 · Cited by 1,450
An optical lattice clock with accuracy and stability at the 10−18 level
Bloom, B. J., Nicholson, T. L., Williams, J. R., Campbell, S. L., Bishof, M., Zhang, X., Zhang, W., Bromley, S. L., & Ye, J. (2014) · Nature · doi:10.1038/nature12941 · Cited by 1,073
Nobel Lecture: Passion for precision
Hänsch, T. W. (2006) · Reviews of Modern Physics · doi:10.1103/revmodphys.78.1297 · Cited by 915
Frequency Comparison of Two High-Accuracy Al + Optical Clocks
Chou, C., Hume, D., Koelemeij, J., Wineland, D., & Rosenband, T. (2010) · Physical Review Letters · doi:10.1103/physrevlett.104.070802 · Cited by 903
Chou, C. W., Hume, D. B., Rosenband, T., & Wineland, D. J. (2010) · Science · doi:10.1126/science.1192720 · Cited by 828
An Atomic Clock with 10 –18 Instability
Hinkley, N., Sherman, J. A., Phillips, N. B., Schioppo, M., Lemke, N. D., Beloy, K., Pizzocaro, M., Oates, C. W., & Ludlow, A. D. (2013) · Science · doi:10.1126/science.1240420 · Cited by 817 · cited 1×
“Optical clocks are – due to their orders of magnitude better precision (1) and accuracy (2,3,4) than their microwave counterparts realizing the definition of the SI second – new sensors with highest resolving power to, e.”
BackgroundSystematic evaluation of an atomic clock at 2 × 10−18 total uncertainty
Nicholson, T. L., Campbell, S. L., Hutson, R. B., Marti, G. E., Bloom, B. J., McNally, R. L., Zhang, W., Barrett, M. D., Safronova, M. S., Strouse, G. F., et al. (2015) · Nature Communications · doi:10.1038/ncomms7896 · Cited by 780 · cited 1×
“Optical clocks are – due to their orders of magnitude better precision (1) and accuracy (2,3,4) than their microwave counterparts realizing the definition of the SI second – new sensors with highest resolving power to, e.”
BackgroundKómár, P., Kessler, E. M., Bishof, M., Jiang, L., Sørensen, A. S., Ye, J., & Lukin, M. D. (2014) · Nature Physics · doi:10.1038/nphys3000 · Cited by 768 · cited 1×
“Additionally, new geodetic reference frames based on relativistic geodesy (15,16) or a quantum network of clocks (17) can be established.”
BackgroundCryogenic optical lattice clocks
Ushijima, I., Takamoto, M., Das, M., Ohkubo, T., & Katori, H. (2015) · Nature Photonics · doi:10.1038/nphoton.2015.5 · Cited by 627 · cited 1×
“Optical clocks are – due to their orders of magnitude better precision (1) and accuracy (2,3,4) than their microwave counterparts realizing the definition of the SI second – new sensors with highest resolving power to, e.”
BackgroundNobel Lecture: Defining and measuring optical frequencies
Hall, J. L. (2006) · Reviews of Modern Physics · doi:10.1103/revmodphys.78.1279 · Cited by 614
Research works printed but not linked: 1
- Vermeer, M. Chronometric levelling, Reports of the Finnish Geodetic Institute 83, 2 (1983).
Cited by
Items 401–455 of 455
Yudin, V. I., Basalaev, M. Y., Radnatarov, D. A., Gromov, I., Radchenko, M. D., Kobtsev, S. M., & Taychenachev, A. V. (2024) · Письма в Журнал экспериментальной и теоретической физики · doi:10.31857/s0370274x24100033
Contributions of the optical lattice clock NICT-Sr1 to TAI calibration and UTC(NICT) steering
Hachisu, H., Nemitz, N., Tønnes, M., Ito, H., Ohtsubo, N., Miyauchi, Y., Morikawa, M., Matsubara, K., Gotoh, T., & Ido, T. (2024) · Journal of Physics Conference Series · doi:10.1088/1742-6596/2889/1/012018 · Cited by 4
Curtis, E. A., Tofful, A., Parsons, A. O., Robertson, B., & Godun, R. M. (2024) · Journal of Physics Conference Series · doi:10.1088/1742-6596/2889/1/012044 · Cited by 1
Clock-offset measurement over a 50 km nonreciprocal fiber link with linear optical sampling
Meng, F., Wu, Y., Song, Y., Tang, B., & Zhang, Z. (2024) · Optics Continuum · doi:10.1364/optcon.545847
Meng, F., Ma, C., Zhang, D., Li, Y. L., Meng, L., Xing, C., & Jia, J. (2025) · Scientific Reports · doi:10.1038/s41598-025-85527-9
RetractedA, J. J. D. L. O., Ramírez, H. A. T., Cortés, N. B., Rodriguez, C. F. R., Guevara, A. G., S, A. D. R., L, M. A. G., & M, D. E. S. (2025) · Measurement Sensors · doi:10.1016/j.measen.2024.101531
Niedersachsen quantum communications testbed
Kadum, J. E., Kniggendorf, A., Kühl, A., Hreibi, A., Mukherjee, S., Kronjäger, J., & Kück, S. (2025) · Measurement Sensors · doi:10.1016/j.measen.2024.101774 · Cited by 3
Self-citationWang, B., Yang, Y., Zhang, H., Hu, R., Mao, H., Huang, Y., Gao, K., & Guan, H. (2025) · Sensors · doi:10.3390/s25041044
“…laser [6–9], and the femtosecond optical frequency comb [10,11], optical clocks play an important role in the measurement of basic physical constants [12], the verification of general relativity [13,14], gravitational wave measurement [15–17], and other precise measurement physics [18,19].”
Yu, D., Xue, X., Zhang, J., Zhang, S., & Chen, J. (2025) · Advanced Quantum Technologies · doi:10.1002/qute.202400491
Kühl, A., Koke, S., Koczwara, A., Waterholter, T., & Grosche, G. (2025) · Annalen der Physik · doi:10.1002/andp.202400414
Self-citationJingjing, 夏. X., Feng, 郭. G., Yanyan, 刘. L., Lu, X., & Chang, H. (2025) · Acta Optica Sinica · doi:10.3788/aos241628 · Cited by 2
Zhou, Q., Zhang, X., Zang, Q., Wu, M., Yuan, R., Zhang, Y., Wang, D., Liu, Y., Fan, L., Dong, R., et al. (2025) · Optical Fiber Technology · doi:10.1016/j.yofte.2025.104184
Fiber-optic round trip time transfer tolerant to OSNR degradation via forward frequency transmission
Dong, J., Li, G., Wang, Z., Yu, S., & Luo, B. (2025) · Optics Letters · doi:10.1364/ol.551558 · Cited by 1
Wang, H., Jiang, W., Zheng, B., et al. (2025) · IEEE International Conference on Power, Electronics and Computer Applications (ICPECA) · doi:10.1109/icpeca63937.2025.10928843
“Given the high demands for time synchronization accuracy in advanced timing services [1], relativistic geodesy [2], and meticulous measurement applications [3], precise time transfer is of critical importance.”
Differential Signals-of-Opportunity Timing Back-Up Method on VHF Band for Critical Infrastructures
Olkkonen, M., Mäkelä, M., & Kaasalainen, S. (2025) · IEEE Access · doi:10.1109/access.2025.3558991
“Currently, the most accurate long-distance GNSS-free time and frequency transfer is done using point-to-point fibre-optic links [8], [9], [10], [11].”
Performing MHz-Level Repetition Rate Tuning for Coherent Dual-Microcomb Interferometry
Yan, E., Peng, M., Tang, J., Huang, J., Tian, D., Liu, S., Meng, Z., Li, X., Zhu, L., Yan, S., et al. (2025) · Micromachines · doi:10.3390/mi16040448
“In recent years, optical frequency combs (OFCs) have emerged as revolutionary light sources, playing pivotal roles in various fields, including laser ranging [1–3], photonic microwave generation [4,5], spectroscopy [6,7], and atomic clocks [8,9].”
Sub-100 Femtosecond Precision Clock-Offset Measurement Over a 100 Km Fiber LinkPreprint
Meng, F., Zhang, Z., Wu, Y., & Song, Y. (2025) · SSRN Electronic Journal · doi:10.2139/ssrn.5243164
Dong, J., Wang, Z., Ding, S., Wang, B., Yu, S., Luo, B., & Guo, H. M. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3578711 · Cited by 2
“F IBER-OPTIC time transfer, a method for delivering precise timing signals, is widely used in fields such as positioning, navigation, timing (PNT) [1], [2], [3], fundamental physics [4], [5], [6], and geodesy [7], [8], [9].”
Interoperability in optical frequency transfer fiber optic links
Śliwczyński, Ł., Krehlik, P., Buczek, Ł., Schnatz, H., Kronjäger, J., Turza, K., & Binczewski, A. (2025) · Optics Express · doi:10.1364/oe.566863 · Cited by 1
Self-citationResearch on the ensemble timescale algorithm incorporated with an optical clock
Wang, X., Chen, G., Zhang, L., Jiang, D., Wang, H., Liu, K., Qiu, Z., & Wang, M. (2026) · Physica Scripta · doi:10.1088/1402-4896/ae73f9
Enhanced timing of a 113 km O-TWTFT link with complex maximum likelihood estimation process
方, Y.-C. 宇. F., Guan, J.-Y., Shen, Q., Han, J.-J., Hou, L., Lian, M.-Z., Wang, Y., Liu, W.-Y., Ren, J.-G., Peng, C.-Z., et al. (2025) · Chinese Physics B · doi:10.1088/1674-1056/ae1120
“These precision levels are essential for applications such as the redefinition of the second [6] and precision geodesy [7, 8].”
Making It Possible - Portable Strontium Lattice Clock
Smith, M., Palomurto, P., Catanach, T., Kale, Y. B., Singh, Y., Hill, I. R., Hussein, S., & Allen, B. P. (2025) · Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS) · doi:10.1109/eftf/ifcs64367.2025.11194418
“The work presented here, when completed, is expected to have a wide range of applications, from geodesy and gravitational red-shift measurements [4] to frequency references for applications such as quantum-enabled radar [5].”
Phase Noise Optimization of the Fiber-Based Frequency Dissemination System
Li, W., Dai, H., Pang, Z., & Wang, B. (2025) · Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS) · doi:10.1109/eftf/ifcs64367.2025.11194690
“High-precision time and frequency signals are of significant importance in many fundamental research and engineering applications [1-2].”
Velocity-comb modulation transfer spectroscopy
Guan, X., Zheng, X., Liu, Z., Wang, Z., Zhang, J., Gao, X., Chang, P., Shi, T., & Chen, J. (2025) · Physical Review Applied · doi:10.1103/rwzv-p2fj · Cited by 3
Hitachi, K., Imai, H., Nishiyama, K., et al. (2025) · IEEE Photonics Conference · doi:10.1109/ipc65510.2025.11282047
“This transfer enables long-distance optical frequency comparisons through optical fiber networks using fiber noise cancellation techniques and supports real-time monitoring of geophysical phenomena [1].”
Research progress on precision measurement based on optical clocks
Xiaotong, L., Jin, C., & Hong, C. S. (2025) · Acta Physica Sinica · doi:10.7498/aps.75.20251594 · Cited by 1
Determining of Geopotential Difference With Multi-GNSS Undifferenced Time–Frequency Signals
Xu, W. S., & Zhang, P. (2026) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2026.3664549
“Recent breakthroughs in fiber-optic and coaxial time transfer technologies have facilitated continental-scale clock networks for geopotential di ff erence determination [9], [10], [11], [12], [13], [14], [15].”
Robust phase stabilization of a dark quantum channel over a 120 km deployed fiber link
Ahn, D., Burenkov, I. A., Jabir, M. V., Merzouki, M., Kuo, P. S., Battou, A., Gerrits, T., & Polyakov, S. V. (2026) · Optica · doi:10.1364/optica.586649
OTSUKA, A. (2026) · SSRN Electronic Journal · doi:10.2139/ssrn.6345093
Fiber link stabilization with a multicore fiber amplifier
Liu, Y., Nakamura, T., Elson, D. J., Wakayama, Y., McLemore, C. A., Hayashi, T., Mazur, M., Fontaine, N. K., Quinlan, F., & Hoghooghi, N. (2026) · Optics Letters · doi:10.1364/ol.592028
OTSUKA, A. (2026) · SSRN Electronic Journal · doi:10.2139/ssrn.6502460
Bouchand, R. (2017) · theses.fr (ABES) · doi:10.70675/90fecec0z8394z414az84f9zfdbda855da65 · Cited by 1
Non-equilibrium long-range phase transition in cold atoms : theory and experiment
Mançois, V. (2018) · theses.fr (ABES) · doi:10.70675/0671a0cfzf84az4008zbf0ez4a79d376eed3
Cavity non destructive detection on an optical lattice clock
Vallet, G. (2018) · theses.fr (ABES) · doi:10.70675/85e7973fz4a2cz4b98zab1czbc647c3921c1 · Cited by 1
Tran, D. B. A. (2019) · theses.fr (ABES) · doi:10.70675/948b4b9cz0fcaz4a4cz9798za4789c7798fa · Cited by 1
Cambier, V. (2019) · theses.fr (ABES) · doi:10.70675/b79eb559z5f59z469cz99a6z5bc084c58e1b · Cited by 3
Spectral Hole Burning for Ultra-stable Lasers
Zhang, S. (2022) · theses.fr (ABES) · doi:10.70675/24492553zb5faz421ez9dffz9fc424d5be33
Foucault, Y. (2022) · theses.fr (ABES) · doi:10.70675/18f7a653zb116z498fz8a18zddca5d8bf64a · Cited by 1
Tønnes, M. (2022) · theses.fr (ABES) · doi:10.70675/1a6f6cbbz8313z461bza0e3z75d240cee613 · Cited by 2
Développement d'un système laser stabilisé en fréquence, compact, fibré, à vocation transportable
Mehlman, A. (2023) · theses.fr (ABES) · doi:10.70675/1bd6c3ccz4436z4ca3z8b50za91af286a290
An optical lattice clock with a bosonic isotope of mercury
Zyskind, C. (2024) · theses.fr (ABES) · doi:10.70675/80b88a7bz62ccz443cz84f2z3237076eba07 · Cited by 3
Zhao, W., Yu, S., Wang, X. E., Xue, W., Xing, Y., Zhang, Y., Liu, T., Ren, X., Li, T., & Zhang, S. (2026) · Metrologia · doi:10.1088/1681-7575/ae6c2c
Impact of Earth Tide Models on Reducing Uncertainty in Continuous Operation of Optical Atomic Clocks
Ichikawa, R., Tanaka, Y., & Honda, R. (2026) · International Association of Geodesy symposia · doi:10.1007/1345_2026_361
Elmaghraby, A., Krawinkel, T., Kersten, T., & Schön, S. (2026) · International Association of Geodesy symposia · doi:10.1007/1345_2026_382
Picosecond-Level Time Transfer Over a 656–km Desert Overhead Fiber Link
Guo, X. S., Liu, B., Wen, J., Wang, X., Chen, J., Chu, Z., Liu, T., Dong, R., & Zhang, S. (2026) · Journal of Lightwave Technology · doi:10.1109/jlt.2026.3708497
“T IME synchronization is a fundamental capability for modern scientific and engineering infrastructures, including navigation, communication, radio astronomy, deep-space exploration, and large-scale distributed measurement systems [1], [2], [3].”
Capture of Thulium Atoms into a Magneto-Optical Trap and Their Detection Using the 530-nm Transition
Provorchenko, D. I., Dvurechenskii, A. A., Bessmertnykh, B. A., Mishin, D., Трегубов, Д. О., Kolachevsky, N., & Golovizin, A. A. (2026) · Journal of Experimental and Theoretical Physics Letters · doi:10.1134/s0021364026601314 · Cited by 1
“…[1– 4], and due to their record-breaking accuracy and stability, such systems can be used in relativistic geodesy and gravity mapping of the Earth [5, 6], as well as in testing fundamental physical theories: from general relativity [7–9] to searching for variations in fundamental constants and…”
Fundamental Physics Studies with Molecules and Emerging Applications
Maddaloni, P., Consolino, L., & Natale, P. D. (2025) · Springer series on atomic, optical, and plasma physics · doi:10.1007/978-3-031-99439-5_6
Xu, R. L., Shen, W., Fok, H. S., Zhang, P., Li, L., Wang, L., Wu, K., Ning, A., Xie, Y., Shen, Z., et al. (2026) · The European Physical Journal C · doi:10.1140/epjc/s10052-026-15885-9 · Cited by 2
Compatibility of a Multicore EDFA for Ultrastable Frequency Transfer
Liu, Y., Nakamura, T., Elson, D. J., Wakayama, Y., McLemore, C. A., Hayashi, T., Mazur, M., Fontaine, N. K., Quinlan, F., & Hoghooghi, N. (2026) · Conference on Lasers and Electro-Optics · doi:10.1364/cleo_si.2026.stu2i.4
Sub-picosecond synchronized multi-faceted fronthaul with one-sample-per-symbol coherent detection
Zhang, C., Zhu, Y., Lin, J., Zou, Y., Fang, X., Hu, Y., Hu, W., Hu, W., Chen, Z., & Xie, X. (2026) · Nature Communications · doi:10.1038/s41467-026-76739-2
“Afterestablishinga feedback loop 38,39 , remote clock phases are locally extracted, allowing real-time compensation for fi ber link delay fl uctuations and enabling time synchronization with a stable propagation delay.”
Record-breaking optical frequency dissemination over 2,067 km fiber network
Chen, Z., KEmi, X., & Guo, H. (2026) · eLight · doi:10.1186/s43593-026-00137-w
“…dissemination supports a wide range of frontier applications, including international optical clock comparisons [1, 2], relativistic geodesy [3], very-long-baseline interferometry [4–6], distributed quantum networks [7], fundamental physics [8–10], and future redefinitions of the SI second…”
Local Determination of Comb Mode Number in Remote Optical Clock Comparison
Liu, H., Tian, H., Lu, B., Wang, Q., & Lin, Y. (2026) · Sensors · doi:10.3390/s26175360
“Connected by a 1415 km fiber link, this implementation of two OFCs verified the agreement of two clocks at an uncertainty of 5 × 10 − 17 [16].”
Liu, B., Guo, X., Chen, J., Hong, H., Zhou, Q., Zhang, X., Yuan, R., Lu, R., Liu, T., Dong, R., et al. (2026) · Optics Express · doi:10.1364/oe.612955
Metadata
- Authors
- Lisdat, C., Grosche, G., Quintin, N., Shi, C., Raupach, S. M. F., Grebing, C., Nicolodi, D., Stefani, F., Al-Masoudi, A., Dörscher, S., Häfner, S., Robyr, J.-L., Chiodo, N., Bilicki, S., Bookjans, E., Koczwara, A., Koke, S., Kuhl, A., Wiotte, F., Meynadier, F., Camisard, E., Abgrall, M., Lours, M., Legero, T., Schnatz, H., Sterr, U., Denker, H., Chardonnet, C., Le Coq, Y., Santarelli, G., Amy-Klein, A., Le Targat, R., Lodewyck, J., Lopez, O., & Pottie, P.-E.
- Affiliations
- Physikalisch-Technische Bundesanstalt (DE)
- Centre National de la Recherche Scientifique (FR)
- Leibniz University Hannover (DE)
- Corresponding author
- Grosche, G.
- ORCID
- Venue
- Nature Communications
- Published
- 2016-08-09
- Volume
- 7
- Issue
- 1
- Pages
- 12443-12443
- ISSN
- 2041-1723 (ISSN-L)
- PMC
- PMC4980484
- OpenAlex
- W2233029113
- Semantic Scholar
- 0d0794a04d9b1159270897744230019a8f367c40
- Cited by
- 460
- References
- 53
- Citations by year
- 2026: 27 · 2025: 49 · 2024: 46 · 2023: 48 · 2022: 51 · 2021: 35 · 2020: 50 · 2019: 41 · 2018: 51 · 2017: 46 · 2016: 16
- FWCI
- 24.26
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by-sa
- creativecommons.org/licenses/by/4.0 (tdm)
- creativecommons.org/licenses/by/4.0 (vor)
- Locations
- Nature Communications (publishedVersion, cc-by-sa)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- arXiv (Cornell University) (submittedVersion)
- Institutional Repository of Leibniz Universität Hannover (Leibniz Universität Hannover) (submittedVersion, cc-by-nc-nd)
- HAL (submittedVersion, cc-by-nc)
- RePEc: Research Papers in Economics (submittedVersion)
- CINECA IRIS Institutial research information system (University of Pisa) (submittedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- arXiv (Cornell University)
- Leibniz Universität Hannover (cc-by)
- Funders
- European Association of National Metrology Institutes (SIB-02)
- Equipex
- European Commission
- Deutsche Forschungsgemeinschaft (CRC 1128 (“geo-Q”, RTG 1729, CRC 1128)
- Agence Nationale de la Recherche (Labex First-TF ANR-10-LABX-48-01, ANR 10 LABX 48 01, First-TF ANR-10-LABX-48-01, ANR blanc LIOM 2011-BS04-009-01, 009-01, 10-LABX-48-01, BS04-009-01, ANR-10-LABX-48, ANR-11-EQPX-0039, ANR-10, ANR-10-LABX, 2011-BS04-009-01)
- Centre National d’Etudes Spatiales
- Centre National de la Recherche Scientifique
- Leibniz-Gemeinschaft
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Frequency and Time Standards
- Physical Sciences › Computer Science › Computer Networks and Communications › Network Time Synchronization Technologies
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Quantum Information and Cryptography
- Keywords
- optical frequency transfer, clock distribution, geodesy, fundamental physics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
The claim verdicts this report counts are experimental: their accuracy is not yet measured.
A language model drew the claims from the paper on 2026-10-10, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-10 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (gpt-6-sol).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.