A clock network for geodesy and fundamental science
Open accessThe DOI matches its Crossref record; 47 of the 53 references it cites were found in a registry or an index; 18 of the 22 sources its claims cite were checked for support.
Abstract
Leveraging the unrivalled performance of optical clocks as key tools for geo-science, for astronomy and for fundamental physics beyond the standard model requires comparing the frequency of distant optical clocks faithfully. Here, we report on the comparison and agreement of two strontium optical clocks at an uncertainty of 5 × 10(-17) via a newly established phase-coherent frequency link connecting Paris and Braunschweig using 1,415 km of telecom fibre. The remote comparison is limited only by the instability and uncertainty of the strontium lattice clocks themselves, with negligible contributions from the optical frequency transfer. A fractional precision of 3 × 10(-17) is reached after only 1,000 s averaging time, which is already 10 times better and more than four orders of magnitude faster than any previous long-distance clock comparison. The capability of performing high resolution international clock comparisons paves the way for a redefinition of the unit of time and an all-optical dissemination of the SI-second.
Overview
CoChat Summary
TL;DR
The paper demonstrates a direct all-optical comparison of two independent strontium lattice clocks in Paris and Braunschweig over 1,415 km of telecom fibre, achieving agreement at the 5 × 10−17 level. The fibre link contributes negligibly to the measurement, making the clock performance itself the limiting factor.
Key findings
- Two remote strontium optical clocks were compared with an uncertainty of 5 × 10−17 via a phase-coherent fibre link spanning 1,415 km of telecom fibre.
- A fractional precision of 3 × 10−17 was reached after 1,000 s averaging time, described as 10 times better and more than four orders of magnitude faster than any previous long-distance clock comparison.
- In the more extensive second campaign, the fractional offset between the clocks was (4.7 ± 5.0) × 10−17, with agreement within the combined uncertainties.
- The optical link’s fractional uncertainty was assessed as 2.5 × 10−19, and its instability averaged down faster than the clocks, so the remote comparison was limited by the clocks themselves.
Methods
- Two independent strontium optical lattice clocks were operated at LNE-SYRTE in Paris and PTB in Braunschweig; their frequencies were transferred to Strasbourg through stabilized fibre links and compared using femtosecond frequency combs.
- The study analyzed two measurement campaigns (March and June 2015) with 145 h of accumulated data; frequency ratios were corrected for systematic shifts, gravity-potential/redshift differences, and counter synchronization offsets.
- The main analysis combined local clock-to-transfer-laser comparisons, link-noise-cancelled fibre transfer, and Allan-deviation-based uncertainty evaluation for clock, link, and synchronization contributions.
Limitations
- The paper states that the comparison is limited by the instability and uncertainty of the strontium lattice clocks themselves, not by the optical transfer system.
- During the first campaign, counter gates in Paris and Strasbourg were accidentally not synchronized to UTC, requiring indirect reconstruction of the offset with an uncertainty of 10 ms; this is a stated experimental complication.
- Evident from the text: the results are for two clocks of the same species and under a specific fibre-network configuration, so the paper does not directly test broader clock types or fully general network conditions.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Figures



Verification
Claims the paper makes
8 Valid · 3 Not valid · 2 Not checked · 35 Own results and interpretations
The sources with a verdict support this claim; the rest weren’t checked yet, have no full text we could read, or their verdicts aren’t rated yet.
In the paper
“Our work not only enables the above mentioned applications, but also clears the path towards a redefinition of the unit of time, the SI second2425 through regular and practical international comparisons of optical clocks.”
§ A clock network for geodesy and fundamental science > Abstract
What the sources say
- Supportedcites [24] Riehle, F. Towards a redefinition of the second based on optical atomic clocks. C. R. Physique 16, 506–515 (2015). source
The Abstract (p. 1) identifies ways to compare remote optical clocks among the prerequisites for a future redefinition of the SI second. Section 4 (p. 12) discusses international clock comparisons and practical links for carrying them out. The citing authors’ statement that their own work ‘clears the path’ is their conclusion, not a finding attributed to Riehle. (LLM, conf=0.88)
- Not checked — no full text of the sourcecites [25] Margolis, H. Timekeepers of the future. Nat. Phys. 10, 82–83 (2014). source
boostedstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
Every source the paper cites for this claim was checked and supports it.
In the paper
“satellite link techniques do not reach significantly better performance either.”
§ A clock network for geodesy and fundamental science > Abstract
What the sources say
- Supportedcites [20] Hachisu, H. et al. Direct comparison of optical lattice clocks with an intercontinental baseline of 9000, km. Opt. Lett. 39, 4072–4075 (2014). source
On p. 3, the paper reports a 1.6 × 10⁻¹⁵ uncertainty for its satellite-linked clock comparison and gives 6 × 10⁻¹⁶ for a comparison using local Cs fountain clocks. Its p. 1 discussion also describes the performance limits of the GPSCP and TWCP satellite techniques. These passages support the claim that the satellite links did not deliver substantially better performance than the microwave-clock comparison discussed. (LLM, conf=0.84)
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“Complemented by phase-coherent telecom fibre links9101112 as extremely powerful tools for frequency dissemination on a continental scale”
§ A clock network for geodesy and fundamental science > Abstract
What the sources say
- Not checked — no full text of the sourcecites [9] Predehl, K. et al. A 920-Kilometer optical fiber link for frequency metrology at the 19th decimal place. Science 336, 441–444 (2012). source
- Supportedcites [10] Lopez, O. et al. Ultra-stable long distance optical frequency distribution using the Internet fiber network. Opt. Express 20, 23518–23526 (2012). source
The Introduction (p. 3) describes a phase-stabilized 540 km link on a public telecom network for disseminating ultra-stable optical signals and calls the approach scalable. It also discusses extending frequency distribution to a larger scale, supporting the claim about these links as tools for continental-scale dissemination. (LLM, conf=0.86)
- Partly supportedcites [11] Calosso, C. E. et al. Doppler-stabilized fiber link with 6 dB noise improvement below the classical limit. Opt. Lett. 40, 131–134 (2015). sourceExperimental — accuracy not yet measured
The passage labeled Abstract (p. 2) calls optical fiber links a key tool for frequency dissemination and describes coherent links using standard telecom fiber. But the reported experiment used a 47 km metropolitan link (Abstract, pp. 1, 3); our copy does not establish frequency dissemination on a continental scale. (LLM, conf=0.84)
boosted- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“The details of the actual implementation of state preparation and interrogation being quite different in the two experimental realizations of a Sr lattice clock5212223, systematic and statistical uncertainties are highly independent and uncorrelated.”
§ A clock network for geodesy and fundamental science > Results > Optical clock performance
What the sources say
- Partly supportedcites [5] Le Targat, R. et al. Experimental realization of an optical second with strontium lattice clocks. Nat. Commun. 4, 2109 (2013). sourceExperimental — accuracy not yet measured
The OLC architecture section says the two Sr clocks differ in key features, and the Figure 3 caption treats their combined systematic uncertainty as that of two uncorrelated clocks. Figure 1 describes independent probe feedback, but the paper does not establish that state preparation and interrogation are quite different or explicitly say that the clocks’ statistical uncertainties are uncorrelated. (LLM, conf=0.82)
- Could not verifycites [21] Falke, S. et al. A strontium lattice clock with 3 × 10−17 inaccuracy and its frequency. New J. Phys. 16, 073023 (2014). sourceExperimental — accuracy not yet measured
Section 2 describes the preparation and interrogation of this paper’s Sr clock, and section 5 compares its measured frequency with results from other laboratories. Neither passage describes differences between two Sr-clock implementations or says that their systematic and statistical uncertainties are independent or uncorrelated. Searches for those terms and the claimed comparison found no supporting passage. (LLM, conf=0.76)
- Could not verifycites [22] Grebing, C. et al. Realization of a time-scale with an optical clock. Optica 3, 563–569 (2016). sourceExperimental — accuracy not yet measured
Section II (p. 2) describes one Sr lattice clock operated in two campaigns, and the Supplementary Material (p. 7) describes its preparation and interrogation. The paper does not compare the implementations of two Sr clocks or say that their systematic and statistical uncertainties are uncorrelated; the independence mentioned in Data Analysis (p. 3) concerns two Cs fountain clocks. (LLM, conf=0.76)
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“This international all-optical clock measurement surpasses the accuracy of the best possible comparison achievable by measurements against primary caesium clocks by one order of magnitude5212223.”
§ A clock network for geodesy and fundamental science > Results > Campaigns to compare the strontium optical clocks
What the sources say
- Partly supportedcites [5] Le Targat, R. et al. Experimental realization of an optical second with strontium lattice clocks. Nat. Commun. 4, 2109 (2013). sourceExperimental — accuracy not yet measured
The Discussion (page unavailable) reports that a direct comparison of two strontium optical clocks achieved agreement better than three of the best caesium fountains could resolve. But the reported optical comparison uncertainty was 1.5 × 10⁻¹⁶ versus 3.1 × 10⁻¹⁶ for the caesium-based comparison—not an order of magnitude—and the Discussion describes comparisons between clocks at different institutes as future work, not this measurement. (LLM, conf=0.88)
- Partly supportedcites [21] Falke, S. et al. A strontium lattice clock with 3 × 10−17 inaccuracy and its frequency. New J. Phys. 16, 073023 (2014). sourceExperimental — accuracy not yet measured
The Introduction (page not available) says the best caesium fountain clocks limit absolute frequency measurements to about 2–4 × 10⁻¹⁶. Results and discussion (page not available) says direct optical-clock comparisons achieve smaller relative uncertainties, but does not quantify a tenfold advantage for an international all-optical measurement. This paper’s own absolute measurement used caesium fountains, so its nearly tenfold advantage refers to the strontium clock’s systematic uncertainty, not that measurement’s accuracy. (LLM, conf=0.85)
- Partly supportedcites [22] Grebing, C. et al. Realization of a time-scale with an optical clock. Optica 3, 563–569 (2016). sourceExperimental — accuracy not yet measured
Optical Clock Operation (p. 2) says the strontium clock’s systematic uncertainty is at least an order of magnitude below that of PTB’s primary caesium fountains. But this paper’s measurement compares a local strontium clock with caesium fountains; Data Analysis (p. 4) discusses agreement with measurements at other institutes, not the accuracy of the cited international all-optical measurement. (LLM, conf=0.86)
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
28 more claims · 1 with their cited sources checked
Create a free account to see all 48 claims and every source verdict.
- It may state two separate claims as one. 12
- Probably not a substantial claim. 3
- The quote only partly states this claim. 1
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Furthermore, the frequency of two atomic clocks can be compared via an interferometric fiber link (IFL), which supports sub-10 -19 accuracy over hundreds of kilometers [5-10].”
From Long-distance chronometric leveling with a portable optical clock (2024) · cites this paper as [6]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Phase compensated optical fiber links enable high accuracy atomic clocks separated by thousands of kilometers to be compared with unprecedented statistical resolution.”
From Test of Special Relativity Using a Fiber Network of Optical Clocks (2017) · cites this paper as [9]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“They reached the accuracy of 3×10 -17 using two Sr-lattice clocks with an uncertainty of 5×10 -17 between Paris and Braunschweig stations.”
From Time transfer and significance of vertical land motion in relativistic geodesy applications: a review paper (2023) · cites this paper as Lisdat et al. (2016)
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“A first attempt in this direction was the comparison of two strontium optical clocks between PTB and OBSPARIS via a fibre link, showing an uncertainty and agreement with the geodetic results of about 5 × 10 -17 (Lisdat et al. 2016).”
From Geodetic methods to determine the relativistic redshift at the level of 10 $$^{-18}$$ - 18 in the context of international timescales: a review and practical results (2018) · cites this paper as Lisdat et al. 2016
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Therefore, phase-coherent optical links have been developped using principally an optical fibre as a medium for the propagation [108, 109, 75, 74], attaining spectacular stability and accuracy in the range 10 -19 and below.”
From Chronometric Geodesy: Methods and Applications (2019) · cites this paper as [75]
Experimental — accuracy not yet measured
8 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Frequency Ratio of Al+and Hg+Single-Ion Optical Clocks; Metrology at the 17th Decimal Place
Rosenband, T., Hume, D. B., Schmidt, P. O., Chou, C. W., Brusch, A., Lorini, L., Oskay, W. H., Drullinger, R. E., Fortier, T. M., Stalnaker, J. E., et al. (2008) · Science · doi:10.1126/science.1154622 · Cited by 1,450
An optical lattice clock with accuracy and stability at the 10−18 level
Bloom, B. J., Nicholson, T. L., Williams, J. R., Campbell, S. L., Bishof, M., Zhang, X., Zhang, W., Bromley, S. L., & Ye, J. (2014) · Nature · doi:10.1038/nature12941 · Cited by 1,073
Nobel Lecture: Passion for precision
Hänsch, T. W. (2006) · Reviews of Modern Physics · doi:10.1103/revmodphys.78.1297 · Cited by 915
Frequency Comparison of Two High-Accuracy Al + Optical Clocks
Chou, C., Hume, D., Koelemeij, J., Wineland, D., & Rosenband, T. (2010) · Physical Review Letters · doi:10.1103/physrevlett.104.070802 · Cited by 903
Chou, C. W., Hume, D. B., Rosenband, T., & Wineland, D. J. (2010) · Science · doi:10.1126/science.1192720 · Cited by 828
An Atomic Clock with 10 –18 Instability
Hinkley, N., Sherman, J. A., Phillips, N. B., Schioppo, M., Lemke, N. D., Beloy, K., Pizzocaro, M., Oates, C. W., & Ludlow, A. D. (2013) · Science · doi:10.1126/science.1240420 · Cited by 817 · cited 1×
“Optical clocks are – due to their orders of magnitude better precision (1) and accuracy (2,3,4) than their microwave counterparts realizing the definition of the SI second – new sensors with highest resolving power to, e.”
BackgroundSystematic evaluation of an atomic clock at 2 × 10−18 total uncertainty
Nicholson, T. L., Campbell, S. L., Hutson, R. B., Marti, G. E., Bloom, B. J., McNally, R. L., Zhang, W., Barrett, M. D., Safronova, M. S., Strouse, G. F., et al. (2015) · Nature Communications · doi:10.1038/ncomms7896 · Cited by 780 · cited 1×
“Optical clocks are – due to their orders of magnitude better precision (1) and accuracy (2,3,4) than their microwave counterparts realizing the definition of the SI second – new sensors with highest resolving power to, e.”
BackgroundKómár, P., Kessler, E. M., Bishof, M., Jiang, L., Sørensen, A. S., Ye, J., & Lukin, M. D. (2014) · Nature Physics · doi:10.1038/nphys3000 · Cited by 768 · cited 1×
“Additionally, new geodetic reference frames based on relativistic geodesy (15,16) or a quantum network of clocks (17) can be established.”
BackgroundCryogenic optical lattice clocks
Ushijima, I., Takamoto, M., Das, M., Ohkubo, T., & Katori, H. (2015) · Nature Photonics · doi:10.1038/nphoton.2015.5 · Cited by 627 · cited 1×
“Optical clocks are – due to their orders of magnitude better precision (1) and accuracy (2,3,4) than their microwave counterparts realizing the definition of the SI second – new sensors with highest resolving power to, e.”
BackgroundNobel Lecture: Defining and measuring optical frequencies
Hall, J. L. (2006) · Reviews of Modern Physics · doi:10.1103/revmodphys.78.1279 · Cited by 614
Research works printed but not linked: 1
- Vermeer, M. Chronometric levelling, Reports of the Finnish Geodetic Institute 83, 2 (1983).
Cited by
Items 301–400 of 455
Optical Frequency Transfer over Submarine Fibers
Clivati, C., Marra, G., Levi, F., Mura, A., Xuereb, A., & Calonico, D. (2020) · Conference on Lasers and Electro-Optics · doi:10.1364/cleo_si.2020.sm2n.1 · Cited by 2
Interrogation of optical Ramsey spectrum and stability study of an 87Sr optical lattice clock
Xia, J., Lu, X., & Chang, H. (2021) · Chinese Physics B · doi:10.1088/1674-1056/ac11e0 · Cited by 2
Hu, L., Tian, X., Wu, G., Shen, J., & Chen, J. (2020) · arXiv (Cornell University) · doi:10.48550/arxiv.2003.13417 · Cited by 4
“[11], [12], enabling transfer distance to up to a few hundred of kilometers [13], [14], [15], [16], [17], [18].”
BackgroundAdvanced laser frequency stabilisation systems for mobile strontium optical lattice clocks
Viswam, S. (2020) · University of Birmingham Institutional Research Archive (University of Birmingham) · Cited by 4
Chapter 1 Theoretical background
(1996) · The Metrical Organization of Beowulf · doi:10.1515/9783110810493.1 · Cited by 2
Improvement of a Doppler simulator in optical performance
Sun, T., Tan, Y., Guo, Y., He, Z., Zhang, L., & Wu, J. (2022) · Optics and Lasers in Engineering · doi:10.1016/j.optlaseng.2022.107404 · Cited by 1
Detection of time variable gravity signals using terrestrial clock networks
Vincent, A., & Müller, J. (2023) · Advances in Space Research · doi:10.1016/j.asr.2023.07.058 · Cited by 6
Comparing Frequency Transfer via GNSS and Fiber in a Common-Clock Configuration
Elmaghraby, A., Krawinkel, T., Schön, S., Kniggendorf, A., Kühl, A., Mukherjee, S., Kronjäger, J., & Piester, D. (2024) · Proceedings of the ... annual Precise Time and Time Interval (PTTI) Systems and Applications Meeting/Proceedings of a meeting - Precise Time and Time Interval (PTTI) Systems and Applications Meeting · doi:10.33012/2024.19592 · Cited by 1
Self-citationUnifying the Nepal height system and China height system based on gravity frequency shift approach
Shanker, K. C., Shen, Z., & Shen, W. (2024) · Geodesy and Geodynamics · doi:10.1016/j.geog.2024.04.005 · Cited by 2
Vision of a Clock-Based Network for Absolute Sea Level Monitoring
Vincent, A., & Müller, J. (2024) · International Association of Geodesy symposia · doi:10.1007/1345_2024_265 · Cited by 1
Michelson interferometer-based coherent demodulation for joint time and frequency transfer
Liu, Q., Gao, H., Dong, J., Wang, Z., Zhang, R., Wu, G., Yu, S., & Luo, B. (2025) · Optics Letters · doi:10.1364/ol.547452 · Cited by 1
Assessment of Measuring Orthometric Height With Multi-GNSS Undifferenced Time–Frequency Signals
Xu, W. S., Song, J., Zhang, P., & Zhao, L. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3565063 · Cited by 1
“For instance, Lisdat et al. [28] conducted an experiment using optical fibers, with a distance of approximately 1415 km and a frequency stability of 5 × 10 17 atomic clock between the Paris Observatory Time and Frequency Reference System Laboratory and the PTB Laboratory, and determined the…”
Zhang, R., Dong, J., Wang, Z., Wu, G., Yu, S., & Luo, B. (2025) · Optics & Laser Technology · doi:10.1016/j.optlastec.2025.113144 · Cited by 1
Two-Way Fiber-Optic Time Synchronization System Based on Feedforward-Feedback Phase Compensation
Dong, J., Wang, Z., Dou, J., Zhang, Y., Yu, S., & Luo, B. (2025) · IEEE Photonics Technology Letters · doi:10.1109/lpt.2025.3583783 · Cited by 1
“F IBER-OPTIC time-frequency transfer systems have been applied across various fields, such as fundamental physics [1], [2], geodesy [3], [4], and metrology [5], [6].”
Bayesian frequency metrology with optimal Ramsey interferometry in optical atomic clocks
Kielinski, T., & Hammerer, K. (2025) · Reports on Progress in Physics · doi:10.1088/1361-6633/ae213d · Cited by 7
“In technology, optical atomic clocks foster potential applications ranging from enhancing global navigation satellite systems [43, 44] and synchronizing large-scale networks [45] to supporting precision geodesy [46–49].”
Chen, F., Li, L.-B., Chen, J.-P., Zhao, K., Guan, J.-Y., Xu, Y., Hou, L., Zhou, F., Peng, C.-Z., Zhang, Q., et al. (2026) · Light Science & Applications · doi:10.1038/s41377-026-02299-1 · Cited by 5
GNSS carrier phase time and frequency comparison for gravity potential determination
Xu, W., Yan, C., & Zhang, P. (2025) · Geophysical Journal International · doi:10.1093/gji/ggaf479 · Cited by 2
Hertz-integral-linewidth lasers based on portable solid-state microresonators
Jin, X., Zhang, X., Zhang, F., Xie, Z., Tang, S., & Yang, Q.-F. (2026) · Photonics Research · doi:10.1364/prj.579096 · Cited by 3
“…a rapidly growing demand for ultra-stable lasers capable of reliable operation in harsh environments, driven by emerging applications such as portable optical atomic clocks [12,13] , geodesy [14,15] , remote sensing [16] , navigation [17] , and miniaturized photonic microwave oscillators [18,19] .”
A High-frequency Geodetic VLBI Experiment for Optical Clock Comparison
Negusini, M., Heo, M.-S., Clivati, C., Xu, S., Ricci, R., Jung, T., Cho, B., Stagni, M., Bortolotti, C., Maccaferri, G., et al. (2026) · Publications of the Astronomical Society of the Pacific · doi:10.1088/1538-3873/ae36d1 · Cited by 2
“…a challenging task: while regional distances can be covered with fiber optic links ( Musha et al. 2008; Droste et al. 2013; Chiodo et al. 2015; Lisdat et al. 2016; Akatsuka et al. 2020; Clivati et al. 2020; Husmann et al. 2021; Clivati et al. 2022 ) , intercontinental clock comparisons are…”
Quantum Clock Synchronization Networks: A Survey
Khalid, U., Ulum, M. S., Mujirin, de Abreu, G. T. F., Björnson, E., & Shin, H. (2026) · IEEE Communications Surveys & Tutorials · doi:10.1109/comst.2026.3694353 · Cited by 3
“This section outlines the fundamental principles of QCS, including the underlying quantum systems, entanglement-based mechanisms, the HOM effect, and core models that define quantum and relativistic limits on achievable timing precision.”
International optical clock comparison using the European optical fiber network
Anonymous, Zyskind, C., Amy‐Klein, A., Benkler, E., Bize, S., Calonico, D., Cantin, E., Chardonnet, C., Clivati, C., Condio, S., et al. (2026) · Physical Review Research · doi:10.1103/l4bh-ryxs · Cited by 8
Self-citationNew Technologies and the Future of Timekeeping
Arias, E. F. (2017) · Astrophysics and space science proceedings · doi:10.1007/978-3-319-59909-0_42 · Cited by 2
Contributing to TAI with Sr optical lattice clocks
Bilicki, S., Bookjans, E., Vallet, G., Abgrall, M., Targat, R. L., & Lodewyck, J. (2017) · Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS) · doi:10.1109/fcs.2017.8089044 · Cited by 3
“OLCs could make it possible to observe sensitive effects, such as topological-defect dark matter [3], test the special relativity theory ([4], [5]) by observing daily variation of frequency difference between clocks, and measure height difference with centimetre precision [6].”
BackgroundSelf-citationTampellini, A., Clivati, C., Pizzocaro, M., Calonico, D., Straullu, S., Curri, V., & Gaudino, R. (2017) · European Conference on Optical Communication · doi:10.1109/ecoc.2017.8345945 · Cited by 1
“Wide-area optical frequency distribution represents a breakthrough in physical and metrological research, enabling to compare atomic clocks across the continent at unprecedented levels of accuracy [2] and enabling improved measurement capability in fields such as fundamental physics or radioastronomy [3].”
BackgroundMethodThe H2020 European project CLONETS: Clock services over optical-fibre networks in Europe
Calonico, D., Vojtěch, J., Campanella, M., Číp, O., Řeřucha, Š., Holzwarth, R., Lessing, M., Saint-Jalm, S., Camargo, F. A., Desruelle, B., et al. (2018) · European Frequency and Time Forum · doi:10.1109/eftf.2018.8409050 · Cited by 3
“The efforts of these projects have culminated in the first international comparison of primary Cs fountains and optical clocks, which was not limited by the link between the clocks ([9, 10]).”
BackgroundSelf-citationPast and Future of Optical Clocks Toward Redefinition of the Second
Ido, T. (2018) · Conference on Precision Electromagnetic Measurements · doi:10.1109/cpem.2018.8501210 · Cited by 1
Measure of the Resonator Stability
Álvarez, M. D. (2019) · Springer theses · doi:10.1007/978-3-030-20863-9_4 · Cited by 1
Chae, E., Nakashima, K., & Yoshioka, K. (2022) · Optics Express · doi:10.1364/oe.458735 · Cited by 1
Jones, J. M., Griffiths, D., Kannanthara, J., Jahangir, M., Antoniou, M., Baker, C., Bongs, K., & Singh, Y. (2022) · International Topical Meeting on Microwave Photonics · doi:10.1109/mwp54208.2022.9997763 · Cited by 2
“This technique has been successfully used to stabilize fibers for direct international optical clock comparisons [11].”
MethodShabanloui, A., Wu, H., & Müller, J. (2023) · International Association of Geodesy symposia · doi:10.1007/1345_2023_220 · Cited by 1
Two-photon transitions in H@C 60 in Debye plasma environment
Joshi, R. (2024) · Spectroscopy Letters · doi:10.1080/00387010.2024.2342250 · Cited by 1
Field-deployable interferometric fibre link terminals with very low temperature sensitivity
Kühl, A., & Kronjäger, J. (2024) · Journal of Physics Conference Series · doi:10.1088/1742-6596/2889/1/012029 · Cited by 1
Self-citationSu, J., Li, C., Liu, Q., Zhao, S., & Wang, X. (2025) · Optics · doi:10.3390/opt6010002 · Cited by 2
Kniggendorf, A., Hreibi, A., Kronjäger, J., & Kück, S. (2025) · Measurement Sensors · doi:10.1016/j.measen.2024.101776 · Cited by 2
Measurements by the method of chronometric leveling through a fiber-optic communication line
Karpik, A. P., Tolstikov, A. S., Golovin, N. N., Сергеевич, Т. А., Krivetskii, A. V., Savinov, K. N., Rachkov, V. D., Boldyrev, V. S., & Дмитриев, А. К. (2025) · Geodesy and Cartography · doi:10.22389/0016-7126-2025-1015-1-10-20 · Cited by 1
Gain-bandwidth-product-induced technical bound in time transfer system without inline amplifiers
Zhang, Y., Chen, Z., & Guo, H. M. (2025) · Journal of Applied Physics · doi:10.1063/5.0267991 · Cited by 2
“This is indispensable in a large variety of fields, to name a few, navigation and positioning[3–5], geodesy[6, 7], search for dark matters[8, 9] and fundamental tests[9–11].”
BackgroundUhren als Höhenmesser: Relativistische Geodäsie
Lisdat, C., & Schnatz, H. (2018) · Physik in unserer Zeit · doi:10.1002/piuz.201870304 · Cited by 1
Self-citationOperation of caesium fountain frequency standards with remote hydrogen maser references
Szymaniec, K., Hendricks, R., Turza, K., Nagórny, B., Dunst, P., Nawrocki, J., Krehlik, P., Śliwczyński, Ł., & Czubla, A. (2018) · Metrologia · doi:10.1088/1681-7575/aae40d · Cited by 1
“Primary frequency standards and optical clocks have been compared via dark fibre links transmitting optical carrier frequency signals [6, 7].”
BackgroundUse of Geodesy and Geophysics Measurements to Probe the Gravitational Interaction
Hees, A., Bourgoin, A., Delva, P., Poncin-Lafitte, C. L., & Wolf, P. (2019) · Fundamental theories of physics · doi:10.1007/978-3-030-11500-5_9 · Cited by 2
A Coherent Fibre Link for Space Geodesy
Calonico, D., Clivati, C., Mura, A., Levi, F., de Cumis, M. S., Amato, L. S., Bianco, G., Sarno, V. D., Aiello, R. G., & Maddaloni, P. (2019) · Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS) · doi:10.1109/fcs.2019.8856080 · Cited by 2
Narrowband and Low-Noise Brillouin Amplification for Coherent Communications
Pelusi, M. D., Inoue, T., & Namiki, S. (2020) · Optical Fiber Communication Conference · doi:10.1364/ofc.2020.m1i.1 · Cited by 1
“clock frequency transfer [1], [2], high resolution optical spectroscopy [3], [4], optical frequency comb line extraction [5], [6], and microwave photonics [7].”
BackgroundExtended gravitational clock compass: New exact solutions and simulations
Neumann, G., Puetzfeld, D., & Rubilar, G. F. (2020) · Physical review. D/Physical review. D. · doi:10.1103/physrevd.102.044027 · Cited by 1
“Finally, it should be mentioned that highly accurate clock networks, which are currently in use [12, 13] and under construction [14, 15], present an exciting direct application of the framework presented here.”
BackgroundClivati, C., Mura, A., Kuttippurath, V., Levi, F., & Calonico, D. (2020) · International Conference on Transparent Optical Networks · doi:10.1109/icton51198.2020.9203251 · Cited by 1
“We acknowledge funding from the project EMPIR-18SIB06-TIFOON, which has received funding from the EMPIR programme co-financed by the Participating States and from the European Union's Horizon 2020 research and innovation programme.”
BackgroundInfluentialKadum, J. E., & Koke, S. (2021) · Frontiers in Optics · doi:10.1364/fio.2021.jtu1a.58 · Cited by 1
Self-citationAtomic Clocks Technologies Supporting Twin-Field QKD in a Real World
Donadello, S., Clivati, C., Meda, A., et al. (2022) · Quantum 2.0 Conference and Exhibition · doi:10.1364/quantum.2022.qtu4c.3 · Cited by 1
High-precision Time-Frequency Signal Simultaneous Transfer System via a WDM-based Fiber LinkPreprint
Qi, Z., Quan, H., Zhao, K., Zhang, X., Wenxiang, X., Faxi, C., Zhao, W., Liu, T., Ruifang, D., & Zhang, S. (2021) · arXiv (Cornell University) · doi:10.48550/arxiv.2106.05826 · Cited by 1
Long range time transfer with optical fiber links and cross comparisons with satellite based methods
Kaur, N. (2018) · theses.fr (ABES) · doi:10.70675/d5a86881zb213z481az8bfez59e7a2d149de · Cited by 2
Mercury optical lattice clock : from high-resolution spectroscopy to frequency ratio measurements
Favier, M. (2017) · theses.fr (ABES) · doi:10.70675/80d64040z4f53z4ed9za362z5046ef8456b7 · Cited by 2
“Towards the end of this thesis, a European comparison involving ultrastable fiber links [119] connecting SYRTE with PTB in Germany [56] and NPL in the United Kingdom allowed us to measure the ratio of the (optical) clock transition νHg/νYb+ for the first time, as well as comparing our mercury clock with Sr clocks at P…”
BackgroundInfluentialKasarda, O. (2015) · DOAJ (DOAJ: Directory of Open Access Journals) · doi:10.5281/zenodo.44702
Horloges à réseau optique au strontium
Lodewyck, J., Targat, R. L., Bilicki, S., Bookjans, E., & Vallet, G. (2016) · Revue française de métrologie · doi:10.1051/rfm/2016006
“La stabilité de la comparaison est entièrement limitée par les horloges, et a permis de démontrer une résolution statistique de 2 × 10−17 après 1 h d’intégration [34].”
Self-citationJitter Analysis of Timing Distribution Systems
Şafak, K., Xin, M., Zhang, Q., Chia, S., Mücke, O. D., & Käertner, F. X. (2017) · Conference on Lasers and Electro-Optics · doi:10.1364/cleo_si.2017.sth4l.1
“Introduction Low-noise transfer of time and frequency standards over large distances provides high temporal resolution for ambitious scientific explorations such as comparison of distant optical clocks [1] and synchronization of X-ray freeelectron lasers to generate ultrashort X-ray pulses [2].”
BackgroundRealization of a Timescale using an Optical Clock
Ido, T. (2017) · The Journal of the Institute of Electrical Engineers of Japan · doi:10.1541/ieejjournal.137.426
Computed Tidal Relativistic Red-Shifts of Frequency Standards on Earth and in Space Stations *
Zhuang, W., Fang, F., Wang, S., Zhao, Y. C., & Li, T. (2017) · Chinese Physics Letters · doi:10.1088/0256-307x/34/11/110601 · Cited by 1
A mercury optical lattice clock with improved magic wavelength control
Guo, C., Favier, M., Calvert, J., Cambier, V., Galland, N., Sarlo, L. D., & Bize, S. (2017) · Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS) · doi:10.1109/fcs.2017.8088940
“This diversity, as it has always been the case, transcends the realm of pure metrology and leads to important applications in fundamental science [3] and, more recently, in geodesy [4].”
BackgroundSynchronization of distant optical clocks across free-space optical links
Newbury, N. R., Sinclair, L. C., Bergeron, H., Swann, W. C., Deschênes, J.-D., Baumann, E., Coddington, I. R., Giorgetta, F. R., & Khader, I. H. (2017) · Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC) · doi:10.1109/cleoe-eqec.2017.8087462
“Networks based on the reciprocal transmission across fiber optics have allowed frequency comparisons between remote clocks across Europe and Japan [2,3].”
BackgroundSeismology with optical links: enabling a global network for submarine earthquake monitoringPreprint
Marra, G., Clivati, C., Richard, L., Tampellini, A., Kronjäger, J., Wright, L., Mura, A., Levi, F., Robinson, S. P., Xuereb, A., et al. (2017) · arXiv (Cornell University) · doi:10.48550/arxiv.1801.02698
Stable and ultra-stable laser systems for a mobile strontium optical clock
Świerad, D. (2018) · University of Birmingham Institutional Research Archive (University of Birmingham) · Cited by 1
Two-Branch Fiber Links for International Clock Networks
Xu, D., Cantin, E., Frank, F., Quintin, N., Mevnadier, F., Tuckev, P., Amy‐Klein, A., Lopez, O., & Pottie, P.-É. (2018) · Conference on Precision Electromagnetic Measurements · doi:10.1109/cpem.2018.8500873
“978-1-5386-0974-3/18/$31.00 ©2018 IEEE I. INTRODUCTION Comparisons of clocks through fiber links at the continental scale have become a reality in Europe [1-3].”
BackgroundInfluentialSelf-citationBogris, A., Νίκας, Θ., & Slavı́k, R. (2018) · European Conference on Optical Communication · doi:10.1109/ecoc.2018.8535335
Liu, J., Deng, X., Zang, Q., Zhang, X., Wang, D., Jiao, D., Kong, W., Liu, T., Deng, X., Jiao, D., et al. (2018) · Asia Communications and Photonics Conference · doi:10.1109/acp.2018.8596062
“In 2016, the remote comparison of two Sr optical clocks respectively located in Paris, France and Braunschweig, Germany was established at an uncertainty of 5×10-17, by using an optical frequency link connecting the two cities with 1415 km of telecom fiber in total[3].”
BackgroundHigh-stability Optical Frequency Transfer with All-Fiber Architecture for Optical Lattice Clocks
Ohmae, N., Sakama, S., & Katori, H. (2019) · IEEJ Transactions on Electronics Information and Systems · doi:10.1541/ieejeiss.139.126
“In addition, one can expect for geodetic applications using clock frequency shift due to the gravitational potential, and experiments are conducted to precisely compare frequencies of high-accuracy atomic clocks placed at distant locations.(10,11) As accuracy and stability of atomic clocks are improved, higher perform…”
Comparing remote atomic clocks via VLBI networks and fiber optic links: the LIFT/MetGeSp perspective
Ricci, R., Negusini, M., Perini, F., Bortolotti, C., Roma, M., Ambrosini, R., Maccaferri, G., Stagni, M., Nanni, M., Kravchenko, E. V., et al. (2019) · European VLBI Network Symposium and Users Meeting (EVN Symposium) · doi:10.22323/1.344.0083
“Atomic clock timing can be effectively used for Very Long Baseline Interferometry (VLBI) applications, but it can also be utilized for relativistic geodesy ([1], [2]) when comparing optical clocks and in the future networks of optical clocks it will provide a redefinition of the SI second [3].”
BackgroundThe TiFOON Project – Time and Frequency Over Optical Networks
Kronjäger, J. (2019) · International Congress of Metrology (CIM) · doi:10.1051/metrology/201915001
Progress on a Surface-Electrode Ion Trap for Optical Frequency Metrology
Delehaye, M., Kersalé, Y., Lacroûte, C., et al. (2019) · doi:10.1109/fcs.2019.8856116
“Such a compact clock would be part of the growing European optical clocks network that already triggers new applications in a large variety of domains, ranging from relativistic geodesy to fundamental science [2, 3].”
BackgroundApplication of ultra-stable laser in coherent optical frequency transfer
Jiao, D., Deng, X., Gao, J., Xu, G., Zang, Q., Zhang, X., Wang, D., Liu, J., Liu, T., Dong, R., et al. (2019) · International Conference on Optical Communications and Networks (ICOCN) · doi:10.1109/icocn.2019.8934311
“Recently, comparison of two strontium optical clocks at an uncertainty of 5×10-17 was achieved via 1415 km telecom link connecting Paris and Braunschweig [9].”
BackgroundA QCL-based metrological-grade source at 6 μm
D’Ambrosio, D., Borri, S., Calonico, D., Clivati, C., Natale, P. D., Pas, M. D., Insero, G., Levi, F., Verde, M., & Santambrogio, G. (2020) · Applied Physics B · doi:10.1007/s00340-020-7388-4
Non-equilibrium long-range phase transition in cold atoms : theory and experiment
Mançois, V. (2018) · DR-NTU (Nanyang Technological University) · doi:10.32657/10356/137079
Unification of global height system at centimeter level using precise frequency signal linksPreprint
Shen, Z., Shen, W., & Zhang, S. (2020) · arXiv (Cornell University) · doi:10.48550/arxiv.2008.05868
“connected byOFL have been carried out and discussed (Lion et al., 2017; Lisdat et al., 2016; Shen et al., 2019; Takano et al., 2016).”
BackgroundMethodShen, W., Wu, K., Sun, X. L., Cai, C., & Shen, Z. (2020) · arXiv (Cornell University) · doi:10.48550/arxiv.2008.06271
A Coherent Optical Fiber Link for Very Long Baseline Interferometry
Clivati, C., Aiello, R. G., Bianco, G., Bortolotti, C., Sarno, V. D., Maddaloni, P., Levi, F., Maccaferri, G., Mura, A., Negusini, M., et al. (2020) · Conference on Lasers and Electro-Optics · doi:10.1364/cleo_si.2020.sm2n.4
Cai, C., Shen, W., Shen, Z., Xu, W. S., & Ning, A. (2020) · arXiv (Cornell University) · doi:10.48550/arxiv.2009.09244
“…approaches of determining the geopotential difference using clocks require connecting two clocks with optical fiber/coaxial cables or satellites to transmit frequency signals or time signals between two stations (Lisdat et al. 2016; Takano et al. 2016; Shen et al. 2017, 2019; Takamoto et al. 2020).”
Extraordinary low systematic frequency shifts in bi-colour thulium optical clockPreprint
Golovizin, A. A., Tregubov, D. O., Fedorova, E. S., et al. (2021) · arXiv (Cornell University) · doi:10.48550/arxiv.2102.07468
Yu, C., An, Z., Li, Y., Guo, H., Tong, H., & Zheng, Z. (2021) · Conference on Lasers and Electro-Optics · doi:10.1364/cleo_at.2021.jw1a.68
Digital Doppler-cancellation servo for ultra-stable optical frequency dissemination over fiberPreprint
Mukherjee, S., Millo, J., Marechal, B., Denis, S., Goavec-Merou, G., Friedt, J., Kersalé, Y., & Lacroûte, C. (2021) · arXiv (Cornell University) · doi:10.48550/arxiv.2111.07891
“Several proposals have argued for the development of ultra-stable optical fiber networks on the continental scale [19], [20].”
BackgroundYudin, V. I., Basalaev, M. Y., Коваленко, Д. В., Тайченачев, А. В., Pollock, J. W., Hansen, A., McGehee, W., & Kitching, J. E. (2022) · Quantum Electronics · doi:10.1070/qel17975
VLBI experiments with the dissemination of a common clock via coherent optical fiber link
Ricci, R., Negusini, M., Perini, F., Bortolotti, C., Roma, M., Maccaferri, G., Stagni, M., Clivati, C., Mura, A., Levi, F., et al. (2022) · European VLBI Network Symposium and Users Meeting (EVN Symposium) · doi:10.22323/1.399.0029
“[11]), in view of a redefinition of the SI second based on optical clock frequency standards (Riehle et al.”
BackgroundOptical Atomic Clocks: From International Timekeeping to Gravity Potential Measurement
Margolis, H. S., Denker, H., Voigt, C., Timmen, L., Grotti, J., Koller, S., Vogt, S., Häfner, S., Sterr, U., Lisdat, C., et al. (2019) · Conference on Lasers and Electro-Optics · doi:10.1364/cleo_si.2019.sm1f.3
Self-citationSchreiber, U. K., & Kodet, J. (2017) · Space sciences series of ISSI · doi:10.1007/978-94-024-1566-7_5
(2016) · Physik in unserer Zeit · doi:10.1002/piuz.201690086
An Optimization Algorithm for Optical Gain in the Multi-EDFAs-based Fiber-optic Time Synchronization
Liu, B., Kong, W., Guo, X., Li, B., Zhang, S., Dong, R., & Liu, T. (2022) · Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS) · doi:10.1109/eftf/ifcs54560.2022.9850958
Ultra-stable Optical Frequency Transfer via 609 km Communication Fiber Link
Zhang, X., Zang, Q., Deng, X., Wang, D., Zhou, Q., Wu, M. F., Liu, T., & Dong, R. (2022) · Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS) · doi:10.1109/eftf/ifcs54560.2022.9850456
Using Fiber Network to Realize Synchronization, Timekeeping and Vibration Sensing
Wang, B., Wang, F., Wang, G., Pang, Z., & Zhang, B. (2022) · IEEE/LEOS Summer Topical Meetings · doi:10.1109/sum53465.2022.9858273
“Beside its basic ability of telecommunication, fiber network can be utilized as medium for time-frequency synchronization [1-8], timekeeping platform for the remote network clocks [9-11], and the sensing medium for vibration detection in the geodesy and earth observation fields [12-18].”
BackgroundMcCarthy, D. D., & Seidelmann, P. K. (2018) · Cambridge University Press eBooks · doi:10.1017/9781108178365.018
Atomic Clocks Technologies for Twin-Field QKD in Real World
Clivati, C., Meda, A., Donadello, S., Levi, F., Genovese, M., Mura, A., Virzì, S., Pittaluga, M., Yuan, Z. L., Shields, A. J., et al. (2023) · Optical Fiber Communication Conference · doi:10.1364/ofc.2023.m2i.1 · Cited by 3
“This became possible in the last decade thanks to the exploitation of telecom optical networks and the introduction of dedicated technologies, specifically narrow-linewidth lasers featuring coherence lengths of 100’000 km, and laser interferometry techniques that allow to detect and cancel with high precision the fluc…”
BackgroundMcCarthy, D. D., & Seidelmann, P. K. (2018) · Cambridge University Press eBooks · doi:10.1017/9781108178365.013
Коваленко, Д. В., Yudin, V. I., Basalaev, M. Y., Strokova, N. V., Тайченачев, А. В., & Prudnikov, O. N. (2023) · Journal of Experimental and Theoretical Physics · doi:10.1134/s106377612308006x
Long-Haul Fiber-Optic Time and Frequency Synchronization
Chen, Y., Dai, H., & Wang, B. (2023) · Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS) · doi:10.1109/eftf/ifcs57587.2023.10272096
“In recent decades, fiber-optic time and frequency synchronization (FOTFS) has played a fundamental role in many fields, such as metrology [1], radio astronomy [2], geodesy [3], navigation as well as telecommunication [4].”
BackgroundCoherent Optical Frequency Dissemination with Passive Phase Noise Cancellation
Zhang, X., Zhou, Q., Deng, X., Zang, Q., Wu, M., Liu, J., Wang, D., Dong, R., Liu, T., & Zhang, S. (2023) · Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS) · doi:10.1109/eftf/ifcs57587.2023.10272144
Coherent Optical Frequency Transfer over 100 km Fiber Link Using Bidirectional Active Optics
Wu, H., Zhang, X., Zhao, W., Fu, Y., Chen, X., Jia, S., Yang, W., Ge, J., Zhang, S., & Yang, H. (2023) · Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS) · doi:10.1109/eftf/ifcs57587.2023.10272206
“The comparison and dissemination of ultra-stable opticalfrequency references on large scales poses a major challenge for various ultra-precision experiments in metrology or fundamental physics [1-4].”
BackgroundWANG, 王. J.-Q., Xiong, Z.-X., & HE, 贺. L.-X. (2022) · Acta Sinica Quantum Optica · doi:10.3788/jqo20222804.0202
A novel scheme for acoustic sensing based on a Floquet optical lattice clock
Yin, M.-J., Wang, T., & CHANG, H. (2024) · Advanced Fiber Laser Conference (AFL) · doi:10.1117/12.3023499
Precise characterisation of AM-to-PM phenomena in fast Si photodiodesPreprint
Budzyń, G., & Barański, J. (2024) · doi:10.1364/opticaopen.25607979.v1
Precise characterisation of AM-to-PM phenomena in fast Si photodiodesPreprint
Budzyń, G., & Barański, J. (2024) · doi:10.1364/opticaopen.25607979
Коваленко, Д. В., Yudin, V. I., Basalaev, M. Y., Strokova, N. V., Taychenachev, A. V., & Prudnikov, O. N. (2023) · Журнал Экспериментальной и Теоретической Физики · doi:10.31857/s0044451023080126
A real-time performance improvement method for composite time scale
王, F. 芳. W., 李, W. 汶. L., Dai, H., 李, C. 春. L., 周, J. 建. Z., 薛, S. 申. X., & 王, B. 波. W. (2024) · Chinese Physics B · doi:10.1088/1674-1056/ad6131
Brillouin Amplifier Autonomously Generating Pump Light with Optimum Frequency Offset
Suda, S., Kurosu, T., & Amano, T. (2024) · doi:10.1364/cleo_at.2024.jw2a.2
“Owing to high gain and very narrow bandwidth, Brillouin amplifier (BA) plays a key role in many areas such as microwave photonics [1], self-coherent communication [2] and optical frequency transfer [3].”
BackgroundDetection and Analysis of Anthropogenic Patterns in a Phase-Stabilized Optical Fiber Network
Husmann, D., Zaugg, S. A., & Morel, J. (2024) · European Frequency and Time Forum · doi:10.1109/eftf61992.2024.10722402
Fu, Y., Zhang, X., Chen, X., Wu, H., Zhao, W., Li, H., Yang, H., Zhang, S., & Ge, J. (2024) · European Frequency and Time Forum · doi:10.1109/eftf61992.2024.10722484
Yudin, V. I., Basalaev, M. Y., Radnatarov, D. A., Gromov, I., Radchenko, M. D., Kobtsev, S. M., & Taǐchenachev, A. V. (2024) · Journal of Experimental and Theoretical Physics Letters · doi:10.1134/s0021364024603130
Metadata
- Authors
- Lisdat, C., Grosche, G., Quintin, N., Shi, C., Raupach, S. M. F., Grebing, C., Nicolodi, D., Stefani, F., Al-Masoudi, A., Dörscher, S., Häfner, S., Robyr, J.-L., Chiodo, N., Bilicki, S., Bookjans, E., Koczwara, A., Koke, S., Kuhl, A., Wiotte, F., Meynadier, F., Camisard, E., Abgrall, M., Lours, M., Legero, T., Schnatz, H., Sterr, U., Denker, H., Chardonnet, C., Le Coq, Y., Santarelli, G., Amy-Klein, A., Le Targat, R., Lodewyck, J., Lopez, O., & Pottie, P.-E.
- Affiliations
- Physikalisch-Technische Bundesanstalt (DE)
- Centre National de la Recherche Scientifique (FR)
- Leibniz University Hannover (DE)
- Corresponding author
- Grosche, G.
- ORCID
- Venue
- Nature Communications
- Published
- 2016-08-09
- Volume
- 7
- Issue
- 1
- Pages
- 12443-12443
- ISSN
- 2041-1723 (ISSN-L)
- PMC
- PMC4980484
- OpenAlex
- W2233029113
- Semantic Scholar
- 0d0794a04d9b1159270897744230019a8f367c40
- Cited by
- 460
- References
- 53
- Citations by year
- 2026: 27 · 2025: 49 · 2024: 46 · 2023: 48 · 2022: 51 · 2021: 35 · 2020: 50 · 2019: 41 · 2018: 51 · 2017: 46 · 2016: 16
- FWCI
- 24.26
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by-sa
- creativecommons.org/licenses/by/4.0 (tdm)
- creativecommons.org/licenses/by/4.0 (vor)
- Locations
- Nature Communications (publishedVersion, cc-by-sa)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- arXiv (Cornell University) (submittedVersion)
- Institutional Repository of Leibniz Universität Hannover (Leibniz Universität Hannover) (submittedVersion, cc-by-nc-nd)
- HAL (submittedVersion, cc-by-nc)
- RePEc: Research Papers in Economics (submittedVersion)
- CINECA IRIS Institutial research information system (University of Pisa) (submittedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- arXiv (Cornell University)
- Leibniz Universität Hannover (cc-by)
- Funders
- European Association of National Metrology Institutes (SIB-02)
- Equipex
- European Commission
- Deutsche Forschungsgemeinschaft (CRC 1128 (“geo-Q”, RTG 1729, CRC 1128)
- Agence Nationale de la Recherche (Labex First-TF ANR-10-LABX-48-01, ANR 10 LABX 48 01, First-TF ANR-10-LABX-48-01, ANR blanc LIOM 2011-BS04-009-01, 009-01, 10-LABX-48-01, BS04-009-01, ANR-10-LABX-48, ANR-11-EQPX-0039, ANR-10, ANR-10-LABX, 2011-BS04-009-01)
- Centre National d’Etudes Spatiales
- Centre National de la Recherche Scientifique
- Leibniz-Gemeinschaft
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Frequency and Time Standards
- Physical Sciences › Computer Science › Computer Networks and Communications › Network Time Synchronization Technologies
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Quantum Information and Cryptography
- Keywords
- optical frequency transfer, clock distribution, geodesy, fundamental physics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
The claim verdicts this report counts are experimental: their accuracy is not yet measured.
A language model drew the claims from the paper on 2026-10-10, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-10 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (gpt-6-sol).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.