Conformal phased surfaces for wireless powering of bioelectronic microdevices
Open accessThe DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
Wireless powering could enable the long-term operation of advanced bioelectronic devices within the human body. Although both enhanced powering depth and device miniaturization can be achieved by shaping the field pattern within the body, existing electromagnetic structures do not provide the spatial phase control required to synthesize such patterns. Here, we describe the design and operation of conformal electromagnetic structures, termed phased surfaces, that interface with non-planar body surfaces and optimally modulate the phase response to enhance the performance of wireless powering. We demonstrate that the phased surfaces can wirelessly transfer energy across anatomically heterogeneous tissues in large animal models, powering miniaturized semiconductor devices (<12 mm3) deep within the body (>4 cm). As an illustration of in vivo operation, we wirelessly regulated cardiac rhythm by powering miniaturized stimulators at multiple endocardial sites in a porcine animal model. A phased electromagnetic surface that conforms to the body surface can regulate cardiac rhythm in a porcine model through the wireless transmission of power to miniaturized semiconductor devices implanted at depths of over 4 cm.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Flat optics with designer metasurfaces
Yu, N., & Capasso, F. (2014) · Nature Materials · doi:10.1038/nmat3839 · Cited by 5,984 · cited 1×
“The structure is a metasurface [20, 21] comprising of reactively loaded rings that generate an engineered phase response optimized for energy transfer into the body.”
BackgroundGabriel, S., Lau, R. W., & Gabriel, C. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/003 · Cited by 4,175
Soft Microfluidic Assemblies of Sensors, Circuits, and Radios for the Skin
Xu, S., Zhang, Y., Jia, L., Mathewson, K. E., Jang, K.-I., Kim, J., Fu, H., Huang, X., Chava, P., Wang, R., et al. (2014) · Science · doi:10.1126/science.1250169 · Cited by 1,199 · cited 1×
“Although electromagnetic devices fabricated on flexible and stretchable substrates have recently been reported, the structures were designed for free-space radiation and do not control phase [18, 19].”
BackgroundConformal piezoelectric energy harvesting and storage from motions of the heart, lung, and diaphragm
Dagdeviren, C., Yang, B. D., Su, Y., Tran, P. L., Joe, P., Anderson, E., Xia, J., Doraiswamy, V., Dehdashti, B., Feng, X., et al. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1317233111 · Cited by 975 · cited 1×
“Batteries, for example, are bulky or have short lifetimes, while methods for harvesting physiological energy sources, such as vibrations [2] or thermal gradients [3], yield low power densities.”
BackgroundWirelessly powered, fully internal optogenetics for brain, spinal and peripheral circuits in mice
Montgomery, K. L., Yeh, A. J., Ho, J. S., Tsao, V., Mohan Iyer, S., Grosenick, L., Ferenczi, E. A., Tanabe, Y., Deisseroth, K., Delp, S. L., et al. (2015) · Nature Methods · doi:10.1038/nmeth.3536 · Cited by 565 · cited 1×
“S4b) can be generated under safe average exposure levels if the duty cycle is below 50%, which meets requirements for use in applications such as optogenetics [26].”
BackgroundSelf-citationWireless power transfer to deep-tissue microimplants
Ho, J. S., Yeh, A. J., Neofytou, E., Kim, S., Tanabe, Y., Patlolla, B., Beygui, R. E., & Poon, A. S. Y. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1403002111 · Cited by 541 · cited 3×
“A previous study used a patterned metal plate for field shaping, but the structure was low-resolution, applicable only on flat surfaces, and required bulky phase delay circuitry [11].”
BackgroundMethodSelf-citationBioelectronic medicines: a research roadmap
Birmingham, K., Gradinaru, V., Anikeeva, P., Grill, W. M., Pikov, V., McLaughlin, B., Pasricha, P., Weber, D., Ludwig, K., & Famm, K. (2014) · Nature Reviews Drug Discovery · doi:10.1038/nrd4351 · Cited by 322
Ultralow-Power Electronics for Biomedical Applications
Chandrakasan, A. P., Verma, N., & Daly, D. C. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160547 · Cited by 285 · cited 3×
“The trajectories of the device are labelled (1), (2) and (3), respectively.”
BackgroundInfluentialWaters, B. H., Sample, A. P., Bonde, P., & Smith, J. R. (2012) · Proceedings of the IEEE · doi:10.1109/jproc.2011.2165309 · Cited by 169
Midfield Wireless Powering of Subwavelength Autonomous Devices
Kim, S., Ho, J. S., & Poon, A. S. Y. (2013) · Physical Review Letters · doi:10.1103/physrevlett.110.203905 · Cited by 110 · cited 3×
“For a microdevice in this sourcereceiver configuration, these transfer efficiencies are about two orders of magnitude greater than those achieved in the near-field by the theoretical optimal source [10], and meets requirements for many bioelectronic sensing and modulation systems.”
BackgroundSelf-citation
Cited by
Hong, Y. J., Jeong, H., Cho, K. W., Lu, N., & Kim, D. (2019) · Advanced Functional Materials · doi:10.1002/adfm.201808247 · Cited by 559
Wireless and battery-free technologies for neuroengineering
Won, S. M., Cai, L., Gutruf, P., & Rogers, J. A. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00683-3 · Cited by 360
Flexible Electrochemical Bioelectronics: The Rise of In Situ Bioanalysis
Yu, Y., Nyein, H. Y. Y., Gao, W., & Javey, A. (2020) · Advanced Materials · doi:10.1002/adma.201902083 · Cited by 349
Soft wearable devices for deep-tissue sensing
Lin, M., Hu, H., Zhou, S., & Xu, S. (2022) · Nature Reviews Materials · doi:10.1038/s41578-022-00427-y · Cited by 334
Flexible Metamaterial Electronics
Jiang, S., Liu, X., Liu, J., Ye, D., Duan, Y., Li, K., Yin, Z., & Huang, Y. (2022) · Advanced Materials · doi:10.1002/adma.202200070 · Cited by 332
Self-rechargeable cardiac pacemaker system with triboelectric nanogenerators
Ryu, H., Park, H.-M., Kim, M.-K., Kim, B., Myoung, H. S., Kim, T. Y., Yoon, H.-J., Kwak, S. S., Kim, J., Hwang, T. H., et al. (2021) · Nature Communications · doi:10.1038/s41467-021-24417-w · Cited by 329
Emerging Modalities and Implantable Technologies for Neuromodulation
Won, S. M., Song, E., Reeder, J. T., & Rogers, J. A. (2020) · Cell · doi:10.1016/j.cell.2020.02.054 · Cited by 291
Continuous monitoring of deep-tissue haemodynamics with stretchable ultrasonic phased arrays
Wang, C., Qi, B., Lin, M., Zhang, Z., Makihata, M., Liu, B., Zhou, S., Huang, Y.-H., Hu, H., Gu, Y., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00763-4 · Cited by 274
Digitally-embroidered liquid metal electronic textiles for wearable wireless systems
Lin, R., Kim, H.-J., Achavananthadith, S., Xiong, Z., Lee, J. K. W., Kong, Y. L., & Ho, J. S. (2022) · Nature Communications · doi:10.1038/s41467-022-29859-4 · Cited by 267
Self-citationA wireless millimetric magnetoelectric implant for the endovascular stimulation of peripheral nerves
Chen, J. C., Kan, P., Yu, Z., Alrashdan, F., Garcia, R., Singer, A., Lai, C. S. E., Avants, B., Crosby, S., Li, Z., et al. (2022) · Nature Biomedical Engineering · doi:10.1038/s41551-022-00873-7 · Cited by 231
In vivo wireless photonic photodynamic therapy
Bansal, A., Yang, F., Xi, T., Zhang, Y., & Ho, J. S. (2018) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1717552115 · Cited by 213
“Prior studies using a phase-controlled transmitter show that exposure to the radio-frequency field results in a mild thermal effect (less than 3 °C) localized near the skin surface (23).”
Self-citationMagnetoelectric materials for miniature, wireless neural stimulation at therapeutic frequencies
Singer, A., Dutta, S., Lewis, E., Chen, Z., Chen, J. C., Verma, N., Avants, B., Feldman, A. K., O’Malley, J., Beierlein, M., et al. (2020) · Neuron · doi:10.1016/j.neuron.2020.05.019 · Cited by 202
Neural recording and stimulation using wireless networks of microimplants
Lee, J., Leung, V., Lee, A.-H., Huang, J., Asbeck, P., Mercier, P. P., Shellhammer, S., Larson, L., Laiwalla, F., & Nurmikko, A. (2021) · Nature Electronics · doi:10.1038/s41928-021-00631-8 · Cited by 195
Review—Textile Based Chemical and Physical Sensors for Healthcare Monitoring
Hatamie, A., Angizi, S., Kumar, S., Pandey, C. M., Simchi, A., Willander, M., & Malhotra, B. D. (2020) · Journal of The Electrochemical Society · doi:10.1149/1945-7111/ab6827 · Cited by 184
Arami, H., Kananian, S., Khalifehzadeh, L., Patel, C. B., Chang, E., Tanabe, Y., Zeng, Y., Madsen, S. J., Mandella, M. J., Natarajan, A., et al. (2022) · Nature Nanotechnology · doi:10.1038/s41565-022-01189-y · Cited by 171
Self-citationZhang, T., Liang, H., Wang, Z., Qiu, C., Peng, Y. B., Zhu, X., Li, J., Ge, X., Xu, J., Huang, X., et al. (2022) · Science Advances · doi:10.1126/sciadv.abk0159 · Cited by 166
Soft Wearable Healthcare Materials and Devices
Lyu, Q., Gong, S., Yin, J., Dyson, J. M., & Cheng, W. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202100577 · Cited by 160
Wireless power delivery techniques for miniature implantable bioelectronics
Singer, A., & Robinson, J. T. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202100664 · Cited by 159
Metasurfaces for bioelectronics and healthcare
Li, Z., Tian, X., Qiu, C.-W., & Ho, J. S. (2021) · Nature Electronics · doi:10.1038/s41928-021-00589-7 · Cited by 159
Self-citationLuan, L., Robinson, J. T., Aazhang, B., Chi, T., Yang, K., Li, X., Rathore, H., Singer, A., Yellapantula, S., Fan, Y., et al. (2020) · Neuron · doi:10.1016/j.neuron.2020.10.011 · Cited by 150
Miniature battery-free bioelectronics
Nair, V., Dalrymple, A. N., Yu, Z., Balakrishnan, G., Bettinger, C. J., Weber, D. J., Yang, K., & Robinson, J. T. (2023) · Science · doi:10.1126/science.abn4732 · Cited by 128
“…versus receiver area (in square millimeters) for ultrasound ( 61 – 63 ), radiofrequency ( 64 , 65 ), magnetoelec-tric ( 66 – 70 ), light ( 71 – 76 ), midfield ( 59 , 77 , 78 ), and capacitive ( 79 – 81 ) power transfer with shallow implants (<1 cm in tissue) and deep implants (>1 cm in tissue).”
Wireless power transfer system for deep-implanted biomedical devices
Iqbal, A., Sura, P. R., Al-Hasan, M., Mabrouk, I. B., & Denidni, T. A. (2022) · Scientific Reports · doi:10.1038/s41598-022-18000-6 · Cited by 105
Toward Bioelectronic Medicine—Neuromodulation of Small Peripheral Nerves Using Flexible Neural Clip
Lee, S., Peh, W. Y. X., Wang, J., Yang, F., Ho, J. S., Thakor, N. V., Yen, S., & Lee, C. (2017) · Advanced Science · doi:10.1002/advs.201700149 · Cited by 96
Self-citationActive photonic wireless power transfer into live tissues
Kim, J., Seo, J., Jung, D., Lee, T., Ju, H., Han, J., Kim, N., Jeong, J., Cho, S., Seol, J. H., et al. (2020) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2002201117 · Cited by 75
High-performance wireless powering for peripheral nerve neuromodulation systems
Tanabe, Y., Ho, J. S., Liu, J., Liao, S.-Y., Zhen, Z., Hsu, S., Shuto, C., Zhu, Z.-Y., Ma, A., Vassos, C., et al. (2017) · PLOS ONE · doi:10.1371/journal.pone.0186698 · Cited by 63
Self-citationExtending the limits of wireless power transfer to miniaturized implantable electronic devices
Dinis, H., Colmiais, I., & Mendes, P. (2017) · Micromachines · doi:10.3390/mi8120359 · Cited by 59
“[13] proposed an improvement over the previous WPT system.”
BackgroundA Fully Integrated RF-Powered Energy-Replenishing Current-Controlled Stimulator
Ha, S., Kim, C., Park, J., Cauwenberghs, G., & Mercier, P. P. (2019) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2018.2881800 · Cited by 35
Study of midfield wireless power transfer for implantable medical devices
Keerthi., K. S., Ilango., K., & Manjula., G. N. (2018) · 2018 2nd International Conference on Biomedical Engineering (IBIOMED) · doi:10.1109/ibiomed.2018.8534820 · Cited by 17
Metadata
- Authors
- Agrawal, D. R., Tanabe, Y., Weng, D., Ma, A., Hsu, S., Liao, S.-Y., Zhen, Z., Zhu, Z.-Y., Sun, C., Dong, Z., Yang, F., Tse, H. F., Poon, A. S. Y., & Ho, J. S.
- Venue
- Nature Biomedical Engineering
- Published
- 2017-03-06
- Volume
- 1
- Issue
- 3
- ISSN
- 2157-846X (ISSN-L)
- OpenAlex
- W2593431024
- Cited by
- 178
- References
- 10
- FWCI
- 6.82
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.