Modelling cancer in microfluidic human organs-on-chips
The DOI matches its Crossref record; 122 of the 122 references it cites were found in a registry or an index.
Abstract
One of the problems that has slowed the development and approval of new anticancer therapies is the lack of preclinical models that can be used to identify key molecular, cellular and biophysical features of human cancer progression. This is because most in vitro cancer models fail to faithfully recapitulate the local tissue and organ microenvironment in which tumours form, which substantially contributes to the complex pathophysiology of the disease. More complex in vitro cancer models have been developed, including transwell cell cultures, spheroids and organoids grown within flexible extracellular matrix gels, which better mimic normal and cancerous tissue development than cells maintained on conventional 2D substrates. But these models still lack the tissue-tissue interfaces, organ-level structures, fluid flows and mechanical cues that cells experience within living organs, and furthermore, it is difficult to collect samples from the different tissue microcompartments. In this Review, we outline how recent developments in microfluidic cell culture technology have led to the generation of human organs-on-chips (also known as organ chips) that are now being used to model cancer cell behaviour within human-relevant tissue and organ microenvironments in vitro. Organ chips enable experimentalists to vary local cellular, molecular, chemical and biophysical parameters in a controlled manner, both individually and in precise combinations, while analysing how they contribute to hu…
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Finally, there is a need for new materials to fabricate the chips because polydimethylsiloxane (PDMS), the most commonly used material, can nonspeci fi cally absorb small molecules [69,70].”
From 3D In Vitro Model (R)evolution: Unveiling Tumor–Stroma Interactions (2021) · cites this paper as [69]
In the citing paper
“By incorporating organoids into a micro fl uidic device, organoids-ona-chip inherit the combined bene fi ts of both micro fl uidics and 3D organoid models, thus providing a unique way to study tumor -stroma interactions and their systemic effects [69,74 -76].”
From 3D In Vitro Model (R)evolution: Unveiling Tumor–Stroma Interactions (2021) · cites this paper as [69]
In the citing paper
“organ-on-a-chip devices are being developed to recreate multiorgan interactions -broadening the focus of investigating speci fi c events at a single organ/tissue scale towards systemic-like interactions [69,83].”
From 3D In Vitro Model (R)evolution: Unveiling Tumor–Stroma Interactions (2021) · cites this paper as [69]
In the citing paper
“Tumor-on-chip models based on these organ-on-chip systems can recreate human tumor microenvironments and now hold great promise as a new resource for cost-effective and higher-throughput screening of anticancer drugs [13,14,15,16,17] and powerful enablers of precision medicine [18].”
From The Tumor-on-Chip: Recent Advances in the Development of Microfluidic Systems to Recapitulate the Physiology of Solid Tumors (2019) · cites this paper as [13]
In the citing paper
“Tumor-on-chip models based on these organ-on-chip systems can recreate human tumor microenvironments and now hold great promise as a new resource for cost-effective and higher-throughput screening of anticancer drugs [13,14,15,16,17] and powerful enablers of precision medicine [18].”
From The Tumor-on-Chip: Recent Advances in the Development of Microfluidic Systems to Recapitulate the Physiology of Solid Tumors (2019) · cites this paper as [13]
3 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Reconstituting organ-level lung functions on a chip
Huh, D., Matthews, B. D., Mammoto, A., Montoya-Zavala, M., Hsin, H. Y., & Ingber, D. E. (2010) · Science · doi:10.1126/science.1188302 · Cited by 4,250
Self-citationBhatia, S. N., & Ingber, D. E. (2014) · Nature Biotechnology · doi:10.1038/nbt.2989 · Cited by 3,305
Self-citationEdmondson, R., Broglie, J. J., Adcock, A. F., & Yang, L. (2014) · ASSAY and Drug Development Technologies · doi:10.1089/adt.2014.573 · Cited by 2,515
T cell exclusion, immune privilege, and the tumor microenvironment
Joyce, J. A., & Fearon, D. T. (2015) · Science · doi:10.1126/science.aaa6204 · Cited by 2,473
A molecular signature of metastasis in primary solid tumors
Ramaswamy, S., Ross, K. N., Lander, E. S., & Golub, T. R. (2003) · Nature Genetics · doi:10.1038/ng1060 · Cited by 2,449
High Interstitial Fluid Pressure - an Obstacle in Cancer Therapy
Heldin, C.-H., Rubin, K., Pietras, K., & Östman, A. (2004) · Nature reviews. Cancer · doi:10.1038/nrc1456 · Cited by 2,222
Induction of angiogenesis during the transition from hyperplasia to neoplasia
Folkman, J., Watson, K., Ingber, D., & Hanahan, D. (1989) · Nature · doi:10.1038/339058a0 · Cited by 1,879
Self-citationDrost, J., & Clevers, H. (2018) · Nature Reviews Cancer · doi:10.1038/s41568-018-0007-6 · Cited by 1,790
Multicellular tumor spheroids: An underestimated tool is catching up again
Hirschhaeuser, F., Menne, H., Dittfeld, C., West, J., Mueller-Klieser, W., & Kunz-Schughart, L. A. (2010) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2010.01.012 · Cited by 1,674
Opportunities and challenges for use of tumor spheroids as models to test drug delivery and efficacy
Mehta, G., Hsiao, A. Y., Ingram, M., Luker, G. D., & Takayama, S. (2012) · Journal of Controlled Release · doi:10.1016/j.jconrel.2012.04.045 · Cited by 1,172
A Human Disease Model of Drug Toxicity–Induced Pulmonary Edema in a Lung-on-a-Chip Microdevice
Huh, D., Leslie, D. C., Matthews, B. D., Fraser, J. P., Jurek, S., Hamilton, G. A., Thorneloe, K. S., McAlexander, M. A., & Ingber, D. E. (2012) · Science Translational Medicine · doi:10.1126/scitranslmed.3004249 · Cited by 993
Self-citationCrossing the endothelial barrier during metastasis
Reymond, N., d'Água, B. B., & Ridley, A. J. (2013) · Nature Reviews Cancer · doi:10.1038/nrc3628 · Cited by 922
Kim, H. J., Li, H., Collins, J. J., & Ingber, D. E. (2016) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1522193112 · Cited by 922
Self-citationThree-dimensional microfluidic model for tumor cell intravasation and endothelial barrier function
Zervantonakis, I. K., Hughes-Alford, S. K., Charest, J. L., Condeelis, J. S., Gertler, F. B., & Kamm, R. D. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1210182109 · Cited by 872
Engineering of functional, perfusable 3D microvascular networks on a chip
Kim, S., Lee, H., Chung, M., & Jeon, N. L. (2013) · Lab on a Chip · doi:10.1039/c3lc41320a · Cited by 872
Maschmeyer, I., Lorenz, A. K., Schimek, K., Hasenberg, T., Ramme, A. P., Hübner, J., Lindner, M., Drewell, C., Bauer, S., Thomas, A., et al. (2015) · Lab on a Chip · doi:10.1039/c5lc00392j · Cited by 861
Human kidney proximal tubule-on-a-chip for drug transport and nephrotoxicity assessment
Jang, K.-J., Mehr, A. P., Hamilton, G. A., McPartlin, L. A., Chung, S., Suh, K.-Y., & Ingber, D. E. (2013) · Integrative Biology · doi:10.1039/c3ib40049b · Cited by 849
Self-citationWang, G., McCain, M. L., Yang, L., He, A., Pasqualini, F. S., Agarwal, A., Yuan, H., Jiang, D., Zhang, D., Zangi, L., et al. (2014) · Nature Medicine · doi:10.1038/nm.3545 · Cited by 837
Small airway-on-a-chip enables analysis of human lung inflammation and drug responses in vitro
Benam, K. H., Villenave, R., Lucchesi, C., Varone, A., Hubeau, C., Lee, H.-H., Alves, S. E., Salmon, M., Ferrante, T. C., Weaver, J. C., et al. (2016) · Nature Methods · doi:10.1038/nmeth.3697 · Cited by 816
Self-citationMacedo, F., Ladeira, K., Pinho, F., Saraiva, N., Bonito, N., Pinto, L., & Gonçalves, F. (2017) · Oncology Reviews · doi:10.4081/oncol.2017.321 · Cited by 775
Development of a primary human Small Intestine-on-a-Chip using biopsy-derived organoids
Kasendra, M., Tovaglieri, A., Sontheimer-Phelps, A., Jalili-Firoozinezhad, S., Bein, A., Chalkiadaki, A., Scholl, W., Zhang, C., Rickner, H., Richmond, C. A., et al. (2018) · Scientific Reports · doi:10.1038/s41598-018-21201-7 · Cited by 754
Self-citationGut-on-a-Chip microenvironment induces human intestinal cells to undergo villus differentiation
Kim, H. J., & Ingber, D. E. (2013) · Integrative Biology · doi:10.1039/c3ib40126j · Cited by 750
Self-citationHuman 3D vascularized organotypic microfluidic assays to study breast cancer cell extravasation
Jeon, J. S., Bersini, S., Gilardi, M., Dubini, G., Charest, J. L., Moretti, M., & Kamm, R. D. (2015) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1417115112 · Cited by 723
Bioprinting of 3D convoluted renal proximal tubules on perfusable chips
Homan, K. A., Kolesky, D. B., Skylar-Scott, M. A., Herrmann, J., Obuobi, H., Moisan, A., & Lewis, J. A. (2016) · Scientific Reports · doi:10.1038/srep34845 · Cited by 699
Preclinical Mouse Cancer Models: A Maze of Opportunities and Challenges
Day, C.-P., Merlino, G., & Van Dyke, T. (2015) · Cell · doi:10.1016/j.cell.2015.08.068 · Cited by 676
In vitro Cell Migration and Invasion Assays
Justus, C. R., Leffler, N., Ruiz-Echevarria, M., & Yang, L. V. (2014) · Journal of Visualized Experiments · doi:10.3791/51046 · Cited by 618
Wang, Y. I., Abaci, H. E., & Shuler, M. L. (2017) · Biotechnology and Bioengineering · doi:10.1002/bit.26045 · Cited by 563
Cancer-associated fibroblasts promote directional cancer cell migration by aligning fibronectin
Erdogan, B., Ao, M., White, L. M., Means, A. L., Brewer, B. M., Yang, L., Washington, M. K., Shi, C., Franco, O. E., Weaver, A. M., et al. (2017) · Journal of Cell Biology · doi:10.1083/jcb.201704053 · Cited by 552
Musah, S., Mammoto, A., Ferrante, T. C., Jeanty, S. S. F., Hirano-Kobayashi, M., Mammoto, T., Roberts, K., Chung, S., Novak, R., Ingram, M., et al. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-017-0069 · Cited by 538
Self-citationA microfluidic 3D in vitro model for specificity of breast cancer metastasis to bone
Bersini, S., Jeon, J. S., Dubini, G., Arrigoni, C., Chung, S., Charest, J. L., Moretti, M., & Kamm, R. D. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2013.11.050 · Cited by 534
Organoid-on-a-chip and body-on-a-chip systems for drug screening and disease modeling
Skardal, A., Shupe, T., & Atala, A. (2016) · Drug Discovery Today · doi:10.1016/j.drudis.2016.07.003 · Cited by 512
Interstitial flow influences direction of tumor cell migration through competing mechanisms
Polacheck, W. J., Charest, J. L., & Kamm, R. D. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1103581108 · Cited by 509
Biomimetic model to reconstitute angiogenic sprouting morphogenesis in vitro
Nguyen, D.-H. T., Stapleton, S. C., Yang, M. T., Cha, S. S., Choi, C. K., Galie, P. A., & Chen, C. S. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1221526110 · Cited by 493
Interconnected Microphysiological Systems for Quantitative Biology and Pharmacology Studies
Edington, C. D., Chen, W. L. K., Geishecker, E., Kassis, T., Soenksen, L. R., Bhushan, B. M., Freake, D., Kirschner, J., Maass, C., Tsamandouras, N., et al. (2018) · Scientific Reports · doi:10.1038/s41598-018-22749-0 · Cited by 487
A microfluidic device for a pharmacokinetic–pharmacodynamic (PK–PD) model on a chip
Sung, J. H., Kam, C., & Shuler, M. L. (2010) · Lab on a Chip · doi:10.1039/b917763a · Cited by 484
Herland, A., van der Meer, A. D., FitzGerald, E. A., Park, T.-E., Sleeboom, J. J. F., & Ingber, D. E. (2016) · PLOS ONE · doi:10.1371/journal.pone.0150360 · Cited by 476
Self-citationHassell, B. A., Goyal, G., Lee, E., Sontheimer-Phelps, A., Levy, O., Chen, C. S., & Ingber, D. E. (2017) · Cell Reports · doi:10.1016/j.celrep.2017.09.043 · Cited by 467
Self-citationAdriani, G., Ma, D., Pavesi, A., Kamm, R. D., & Goh, E. L. K. (2017) · Lab on a Chip · doi:10.1039/c6lc00638h · Cited by 443
Multi-Organ toxicity demonstration in a functional human in vitro system composed of four organs
Oleaga, C., Bernabini, C., Smith, A. S. T., Srinivasan, B., Jackson, M., McLamb, W., Platt, V., Bridges, R., Cai, Y., Santhanam, N., et al. (2016) · Scientific Reports · doi:10.1038/srep20030 · Cited by 442
Organ-on-a-chip devices advance to market
Zhang, B., & Radisic, M. (2017) · Lab on a Chip · doi:10.1039/c6lc01554a · Cited by 437
Orthotopic Models are Necessary to Predict Therapy of Transplantable Tumors in Mice
Killion, J. J., Radinsky, R., & Fidler, I. J. (1998) · Cancer and Metastasis Reviews · doi:10.1023/a:1006140513233 · Cited by 430
A lung-on-a-chip array with an integrated bio-inspired respiration mechanism
Stucki, A. O., Stucki, J. D., Hall, S. R. R., Felder, M., Mermoud, Y., Schmid, R. A., Geiser, T., & Guenat, O. T. (2015) · Lab on a Chip · doi:10.1039/c4lc01252f · Cited by 410
In Vitro Perfused Human Capillary Networks
Moya, M. L., Hsu, Y.-H., Lee, A. P., Hughes, C. C. W., & George, S. C. (2013) · Tissue Engineering Part C: Methods · doi:10.1089/ten.tec.2012.0430 · Cited by 387
3D microtumors in vitro supported by perfused vascular networks
Sobrino, A., Phan, D. T. T., Datta, R., Wang, X., Hachey, S. J., Romero-López, M., Gratton, E., Lee, A. P., George, S. C., & Hughes, C. C. W. (2016) · Scientific Reports · doi:10.1038/srep31589 · Cited by 387
Chen, M. B., Whisler, J. A., Fröse, J., Yu, C., Shin, Y., & Kamm, R. D. (2017) · Nature Protocols · doi:10.1038/nprot.2017.018 · Cited by 385
Engineering microscale cellular niches for three-dimensional multicellular co-cultures
Huang, C. P., Lu, J., Seon, H., Lee, A. P., Flanagan, L. A., Kim, H.-Y., Putnam, A. J., & Jeon, N. L. (2009) · Lab on a Chip · doi:10.1039/b818401a · Cited by 384
Engineering cellular microenvironments to improve cell-based drug testing
Bhadriraju, K., & Chen, C. S. (2002) · Drug Discovery Today · doi:10.1016/s1359-6446(02)02273-0 · Cited by 355
Jain, A., Barrile, R., van der Meer, A., Mammoto, A., Mammoto, T., De Ceunynck, K., Aisiku, O., Otieno, M., Louden, C., Hamilton, G., et al. (2018) · Clinical Pharmacology & Therapeutics · doi:10.1002/cpt.742 · Cited by 325
Self-citationMicrofluidic Endothelium for Studying the Intravascular Adhesion of Metastatic Breast Cancer Cells
Song, J. W., Cavnar, S. P., Walker, A. C., Luker, K. E., Gupta, M., Tung, Y.-C., Luker, G. D., & Takayama, S. (2009) · PLoS ONE · doi:10.1371/journal.pone.0005756 · Cited by 317
Benam, K. H., Novak, R., Nawroth, J., Hirano-Kobayashi, M., Ferrante, T. C., Choe, Y., Prantil-Baun, R., Weaver, J. C., Bahinski, A., Parker, K. K., et al. (2016) · Cell Systems · doi:10.1016/j.cels.2016.10.003 · Cited by 309
Self-citationMechanisms of tumor cell extravasation in an in vitro microvascular network platform
Chen, M. B., Whisler, J. A., Jeon, J. S., & Kamm, R. D. (2013) · Integrative Biology · doi:10.1039/c3ib40149a · Cited by 308
Xu, Z., Gao, Y., Hao, Y., Li, E., Wang, Y., Zhang, J., Wang, W., Gao, Z., & Wang, Q. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2013.02.045 · Cited by 295
Marx, U. (2016) · ALTEX · doi:10.14573/altex.1603161 · Cited by 295
Translational value of mouse models in oncology drug development
Gould, S. E., Junttila, M. R., & de Sauvage, F. J. (2015) · Nature Medicine · doi:10.1038/nm.3853 · Cited by 293
Jeong, S.-Y., Lee, J.-H., Shin, Y., Chung, S., & Kuh, H.-J. (2016) · PLOS ONE · doi:10.1371/journal.pone.0159013 · Cited by 287
Esch, M. B., Mahler, G. J., Stokol, T., & Shuler, M. L. (2014) · Lab Chip · doi:10.1039/c4lc00371c · Cited by 281
van Midwoud, P. M., Janse, A., Merema, M. T., Groothuis, G. M. M., & Verpoorte, E. (2012) · Analytical Chemistry · doi:10.1021/ac300771z · Cited by 274
Vernetti, L., Gough, A., Baetz, N., Blutt, S., Broughman, J. R., Brown, J. A., Foulke-Abel, J., Hasan, N., In, J., Kelly, E., et al. (2017) · Scientific Reports · doi:10.1038/srep42296 · Cited by 271
Tubeless microfluidic angiogenesis assay with three-dimensional endothelial-lined microvessels
Bischel, L. L., Young, E. W. K., Mader, B. R., & Beebe, D. J. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2012.11.005 · Cited by 265
Wang, X., Phan, D. T. T., Sobrino, A., George, S. C., Hughes, C. C. W., & Lee, A. P. (2016) · Lab on a Chip · doi:10.1039/c5lc01050k · Cited by 251
A 3D microfluidic model for preclinical evaluation of TCR-engineered T cells against solid tumors
Pavesi, A., Tan, A. T., Koh, S., Chia, A., Colombo, M., Antonecchia, E., Miccolis, C., Ceccarello, E., Adriani, G., Raimondi, M. T., et al. (2017) · JCI Insight · doi:10.1172/jci.insight.89762 · Cited by 241
A microfluidics platform for combinatorial drug screening on cancer biopsies
Eduati, F., Utharala, R., Madhavan, D., Neumann, U. P., Longerich, T., Cramer, T., Saez-Rodriguez, J., & Merten, C. A. (2018) · Nature Communications · doi:10.1038/s41467-018-04919-w · Cited by 239
Rizvi, I., Gurkan, U. A., Tasoglu, S., Alagic, N., Celli, J. P., Mensah, L. B., Mai, Z., Demirci, U., & Hasan, T. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1216989110 · Cited by 234
A dynamic in vivo-like organotypic blood-brain barrier model to probe metastatic brain tumors
Xu, H., Li, Z., Yu, Y., Sizdahkhani, S., Ho, W. S., Yin, F., Wang, L., Zhu, G., Zhang, M., Jiang, L., et al. (2016) · Scientific Reports · doi:10.1038/srep36670 · Cited by 234
In vitro model of tumor cell extravasation
Jeon, J. S., Zervantonakis, I. K., Chung, S., Kamm, R. D., & Charest, J. L. (2013) · PLoS ONE · doi:10.1371/journal.pone.0056910 · Cited by 233
Sung, K. E., Yang, N., Pehlke, C., Keely, P. J., Eliceiri, K. W., Friedl, A., & Beebe, D. J. (2011) · Integr. Biol. · doi:10.1039/c0ib00063a · Cited by 226
A microengineered pathophysiological model of early-stage breast cancer
Choi, Y., Hyun, E., Seo, J., Blundell, C., Kim, H. C., Lee, E., Lee, S. H., Moon, A., Moon, W. K., & Huh, D. (2015) · Lab on a Chip · doi:10.1039/c5lc00514k · Cited by 222
Jalili-Firoozinezhad, S., Prantil-Baun, R., Jiang, A., Potla, R., Mammoto, T., Weaver, J. C., Ferrante, T. C., Kim, H. J., Cabral, J. M. S., Levy, O., et al. (2018) · Cell Death & Disease · doi:10.1038/s41419-018-0304-8 · Cited by 209
Self-citationRegmi, S., Fu, A., & Luo, K. Q. (2017) · Scientific Reports · doi:10.1038/srep39975 · Cited by 208
Beckwitt, C. H., Clark, A. M., Wheeler, S., Taylor, D. L., Stolz, D. B., Griffith, L., & Wells, A. (2018) · Experimental Cell Research · doi:10.1016/j.yexcr.2017.12.023 · Cited by 208
Sieber, S., Wirth, L., Cavak, N., Koenigsmark, M., Marx, U., Lauster, R., & Rosowski, M. (2018) · Journal of Tissue Engineering and Regenerative Medicine · doi:10.1002/term.2507 · Cited by 199
Lee, J.-H., Kim, S.-K., Khawar, I. A., Jeong, S.-Y., Chung, S., & Kuh, H.-J. (2018) · Journal of Experimental & Clinical Cancer Research · doi:10.1186/s13046-017-0654-6 · Cited by 194
Hsu, Y.-H., Moya, M. L., Hughes, C. C. W., George, S. C., & Lee, A. P. (2013) · Lab on a Chip · doi:10.1039/c3lc50424g · Cited by 192
Mechanobiology of Tumor Growth
Chaudhuri, P. K., Low, B. C., & Lim, C. T. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00042 · Cited by 192
Vernetti, L., Gough, A., Baetz, N., Blutt, S., Broughman, J. R., Brown, J. A., Foulke-Abel, J., Hasan, N., In, J., Kelly, E., et al. (2017) · Scientific Reports · doi:10.1038/srep44517 · Cited by 190
Chen, Y.-A., King, A. D., Shih, H.-C., Peng, C.-C., Wu, C.-Y., Liao, W.-H., & Tung, Y.-C. (2011) · Lab on a Chip · doi:10.1039/c1lc20325h · Cited by 185
Baker, B. M., Trappmann, B., Stapleton, S. C., Toro, E., & Chen, C. S. (2013) · Lab on a Chip · doi:10.1039/c3lc50493j · Cited by 182
Prantil-Baun, R., Novak, R., Das, D., Somayaji, M. R., Przekwas, A., & Ingber, D. E. (2018) · Annual Review of Pharmacology and Toxicology · doi:10.1146/annurev-pharmtox-010716-104748 · Cited by 176
Self-citationMusah, S., Dimitrakakis, N., Camacho, D. M., Church, G. M., & Ingber, D. E. (2018) · Nature Protocols · doi:10.1038/s41596-018-0007-8 · Cited by 167
Self-citationElucidation of the Roles of Tumor Integrin β1 in the Extravasation Stage of the Metastasis Cascade
Chen, M. B., Lamar, J. M., Li, R., Hynes, R. O., & Kamm, R. D. (2016) · Cancer Research · doi:10.1158/0008-5472.can-15-1325 · Cited by 158
The effects of monocytes on tumor cell extravasation in a 3D vascularized microfluidic model
Boussommier-Calleja, A., Atiyas, Y., Haase, K., Headley, M., Lewis, C., & Kamm, R. D. (2019) · Biomaterials · doi:10.1016/j.biomaterials.2018.03.005 · Cited by 158
A biomimetic multicellular model of the airways using primary human cells
Sellgren, K. L., Butala, E. J., Gilmour, B. P., Randell, S. H., & Grego, S. (2014) · Lab Chip · doi:10.1039/c4lc00552j · Cited by 143
Barrile, R., van der Meer, A. D., Park, H., Fraser, J. P., Simic, D., Teng, F., Conegliano, D., Nguyen, J., Jain, A., Zhou, M., et al. (2018) · Clinical Pharmacology & Therapeutics · doi:10.1002/cpt.1054 · Cited by 138
Self-citationCXCL12-CXCR4 axis promotes the natural selection of breast cancer cell metastasis
Sun, Y., Mao, X., Fan, C., Liu, C., Guo, A., Guan, S., Jin, Q., Li, B., Yao, F., & Jin, F. (2014) · Tumor Biology · doi:10.1007/s13277-014-1816-1 · Cited by 137
Faley, S. L., Copland, M., Wlodkowic, D., Kolch, W., Seale, K. T., Wikswo, J. P., & Cooper, J. M. (2009) · Lab on a Chip · doi:10.1039/b902083g · Cited by 136
Therapy response testing of breast cancer in a 3D high-throughput perfused microfluidic platform
Lanz, H. L., Saleh, A., Kramer, B., Cairns, J., Ng, C. P., Yu, J., Trietsch, S. J., Hankemeier, T., Joore, J., Vulto, P., et al. (2017) · BMC Cancer · doi:10.1186/s12885-017-3709-3 · Cited by 135
Li, C. Y., Stevens, K. R., Schwartz, R. E., Alejandro, B. S., Huang, J. H., & Bhatia, S. N. (2014) · Tissue Engineering Part A · doi:10.1089/ten.tea.2013.0667 · Cited by 132
Clear castable polyurethane elastomer for fabrication of microfluidic devices
Domansky, K., Leslie, D. C., McKinney, J., Fraser, J. P., Sliz, J. D., Hamkins-Indik, T., Hamilton, G. A., Bahinski, A., & Ingber, D. E. (2013) · Lab on a Chip · doi:10.1039/c3lc50558h · Cited by 129
Self-citationA pumpless multi‐organ‐on‐a‐chip (MOC) combined with a pharmacokinetic–pharmacodynamic (PK–PD) model
Lee, H., Kim, D. S., Ha, S. K., Choi, I., Lee, J. M., & Sung, J. H. (2017) · Biotechnology and Bioengineering · doi:10.1002/bit.26087 · Cited by 124
Walsh, C. L., Babin, B. M., Kasinskas, R. W., Foster, J. A., McGarry, M. J., & Forbes, N. S. (2009) · Lab Chip · doi:10.1039/b810571e · Cited by 121
Domanský, K., Sliz, J. D., Wen, N., Hinojosa, C. D., Thompson, G., Fraser, J. P., Hamkins-Indik, T., Hamilton, G. A., Levner, D., & Ingber, D. E. (2017) · Microfluidics and Nanofluidics · doi:10.1007/s10404-017-1941-4 · Cited by 114
Self-citationBai, J., Adriani, G., Dang, T.-M., Tu, T.-Y., Leong Penny, H.-X., Wong, S.-C., Kamm, R. D., & Thiery, J.-P. (2015) · Oncotarget · doi:10.18632/oncotarget.4716 · Cited by 110
Characterizing the role of monocytes in T cell cancer immunotherapy using a 3d microfluidic model
Lee, S. W. L., Adriani, G., Ceccarello, E., Pavesi, A., Tan, A. T., Bertoletti, A., Kamm, R. D., & Wong, S. C. (2018) · Frontiers in Immunology · doi:10.3389/fimmu.2018.00416 · Cited by 109
A 3D human renal cell carcinoma-on-a-chip for the study of tumor angiogenesis
Miller, C. P., Tsuchida, C., Zheng, Y., Himmelfarb, J., & Akilesh, S. (2018) · Neoplasia · doi:10.1016/j.neo.2018.02.011 · Cited by 105
Patient-Specific 3D Microfluidic Tissue Model for Multiple Myeloma
Zhang, W., Lee, W. Y., Siegel, D. S., Tolias, P., & Zilberberg, J. (2014) · Tissue Engineering Part C: Methods · doi:10.1089/ten.tec.2013.0490 · Cited by 104
Tang, Y., Soroush, F., Sheffield, J. B., Wang, B., Prabhakarpandian, B., & Kiani, M. F. (2017) · Scientific Reports · doi:10.1038/s41598-017-09815-9 · Cited by 102
Li, R., Hebert, J. D., Lee, T. A., Xing, H., Boussommier-Calleja, A., Hynes, R. O., Lauffenburger, D. A., & Kamm, R. D. (2017) · Cancer Research · doi:10.1158/0008-5472.can-16-0442 · Cited by 100
Stretching Fibroblasts Remodels Fibronectin and Alters Cancer Cell Migration
Ao, M., Brewer, B. M., Yang, L., Franco Coronel, O. E., Hayward, S. W., Webb, D. J., & Li, D. (2015) · Scientific Reports · doi:10.1038/srep08334 · Cited by 96
Engineering a 3D microfluidic culture platform for tumor-treating field application
Pavesi, A., Adriani, G., Tay, A., Warkiani, M. E., Yeap, W. H., Wong, S. C., & Kamm, R. D. (2016) · Scientific Reports · doi:10.1038/srep26584 · Cited by 84
Trastuzumab distribution in an in-vivo and in-vitro model of brain metastases of breast cancer
Terrell-Hall, T. B., Nounou, M. I., ElAmrawy, F., Griffith, J. I. G., & Lockman, P. R. (2017) · Oncotarget · doi:10.18632/oncotarget.19634 · Cited by 84
Ying, L., Zhu, Z., Xu, Z., He, T., Li, E., Guo, Z., Liu, F., Jiang, C., & Wang, Q. (2015) · PLOS ONE · doi:10.1371/journal.pone.0129593 · Cited by 81
Targeting the interplay between myeloma cells and the bone marrow microenvironment in myeloma
Abe, M. (2011) · International Journal of Hematology · doi:10.1007/s12185-011-0949-x · Cited by 81
Mastro, A. M., & Vogler, E. A. (2009) · Cancer Research · doi:10.1158/0008-5472.can-08-4437 · Cited by 78
Montanez-Sauri, S. I., Sung, K. E., Berthier, E., & Beebe, D. J. (2013) · Integrative Biology · doi:10.1039/c3ib20225a · Cited by 77
Amelioration of radiation-induced hematopoietic and gastrointestinal damage by Ex-RAD(R) in mice
Ghosh, S. P., Kulkarni, S. S., Perkins, M. W., Hieber, K. P., Pessu, R. L., Gambles, K., Maniar, M. L., Kao, T., Seed, T. M., & Kumar, K. S. (2012) · Journal of Radiation Research · doi:10.1093/jrr/rrs001 · Cited by 76
Bai, J., Tu, T.-Y., Kim, C., Thiery, J. P., & Kamm, R. D. (2015) · Oncotarget · doi:10.18632/oncotarget.5464 · Cited by 70
Bronchioloalveolar Carcinoma: A Review of Current Concepts and Evolving Issues
Yousem, S. A., & Beasley, M. B. (2007) · Archives of Pathology & Laboratory Medicine · doi:10.5858/2007-131-1027-bcaroc · Cited by 67
Study on Invadopodia Formation for Lung Carcinoma Invasion with a Microfluidic 3D Culture Device
Wang, S., Li, E., Gao, Y., Wang, Y., Guo, Z., He, J., Zhang, J., Gao, Z., & Wang, Q. (2013) · PLoS ONE · doi:10.1371/journal.pone.0056448 · Cited by 65
Guan, P.-P., Yu, X., Guo, J., Wang, Y., Wang, T., Li, J., Κωνσταντόπουλος, Κ., Wang, Z., & Wang, P. (2015) · Oncotarget · doi:10.18632/oncotarget.3274 · Cited by 56
Talukdar, S., & Kundu, S. C. (2013) · Advanced Functional Materials · doi:10.1002/adfm.201300312 · Cited by 55
Pak, C., Callander, N. S., Young, E. W. K., Titz, B., Kim, K., Saha, S., Chng, K., Asimakopoulos, F., Beebe, D. J., & Miyamoto, S. (2015) · Integrative Biology · doi:10.1039/c5ib00071h · Cited by 52
Analysis of the paracrine loop between cancer cells and fibroblasts using a microfluidic chip
Hsu, T.-H., Xiao, J.-L., Tsao, Y.-W., Kao, Y.-L., Huang, S.-H., Liao, W.-Y., & Lee, C.-H. (2011) · Lab on a Chip · doi:10.1039/c1lc20090a · Cited by 51
In Vitro Mimics of Bone Remodeling and the Vicious Cycle of Cancer in Bone
Krishnan, V., Vogler, E. A., Sosnoski, D. M., & Mastro, A. M. (2013) · Journal of Cellular Physiology · doi:10.1002/jcp.24464 · Cited by 51
Scalable Fabrication of Stretchable, Dual Channel, Microfluidic Organ Chips
Novak, R., Didier, M., Calamari, E. L., Ng, C. F., Choe, Y., Clauson, S. L., Nestor, B., Puerta, J., Fleming, R. C., Jalili‐Firoozinezhad, S., et al. (2018) · Journal of Visualized Experiments · doi:10.3791/58151 · Cited by 47
Self-citationRecapitulation of in vivo-like neutrophil transendothelial migration using a microfluidic platform
Wu, X., Newbold, M. A., & Haynes, C. L. (2015) · The Analyst · doi:10.1039/c5an00967g · Cited by 43
Disulfiram Attenuates Osteoclast Differentiation In Vitro: A Potential Antiresorptive Agent
Ying, H., Qin, A., Cheng, T. S., Pavlos, N. J., Rea, S., Dai, K., & Zheng, M. H. (2015) · PLOS ONE · doi:10.1371/journal.pone.0125696 · Cited by 39
Microfluidic Biopsy Trapping Device for the Real-Time Monitoring of Tumor Microenvironment
Holton, A. B., Sinatra, F. L., Kreahling, J., Conway, A. J., Landis, D. A., & Altiok, S. (2017) · PLOS ONE · doi:10.1371/journal.pone.0169797 · Cited by 35
Lang, J. D., Berry, S. M., Powers, G. L., Beebe, D. J., & Alarid, E. T. (2013) · Integrative Biology · doi:10.1039/c3ib20265h · Cited by 35
Microfluidic co-culture devices to assess penetration of nanoparticles into cancer cell mass
Jarvis, M., Arnold, M., Ott, J., Pant, K., Prabhakarpandian, B., & Mitragotri, S. (2017) · Bioengineering & Translational Medicine · doi:10.1002/btm2.10079 · Cited by 32
Wu, X., Newbold, M. A., Gao, Z., & Haynes, C. L. (2017) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/j.bbagen.2017.02.012 · Cited by 30
Regier, M. C., Maccoux, L. J., Weinberger, E. M., Regehr, K. J., Berry, S. M., Beebe, D. J., & Alarid, E. T. (2016) · Biomedical Microdevices · doi:10.1007/s10544-016-0083-x · Cited by 23
Gilardi, M., Bersini, S., Boussommier-Calleja, A., Kamm, R. D., Vanoni, M., & Moretti, M. (2016) · Thrombosis Research · doi:10.1016/s0049-3848(16)30145-1 · Cited by 7
Research works printed but not linked: 1
- Justus, C. R., Leffler, N., Ruiz-Echevarria, M. & Yang, L. V. In vitro cell migration and invasion assays. J. Vis. Exp. 88, 51046 (2014).
Cited by
Tumor microenvironment as a therapeutic target in cancer
Xiao, Y., & Yu, D. (2021) · Pharmacology & Therapeutics · doi:10.1016/j.pharmthera.2020.107753 · Cited by 1,957
Is it time to start transitioning from 2D to 3D cell culture?
Jensen, C., & Teng, Y. (2020) · Frontiers in Molecular Biosciences · doi:10.3389/fmolb.2020.00033 · Cited by 1,640
Arneth, B. (2019) · Medicina · doi:10.3390/medicina56010015 · Cited by 1,250
“Researchers have further explored the possibility of developing drugs that target ECM-integrin signaling to manage cancer [78,79].”
BackgroundDiversity and biology of cancer-associated fibroblasts
Biffi, G., & Tuveson, D. A. (2021) · Physiological Reviews · doi:10.1152/physrev.00048.2019 · Cited by 1,265
Nanomedicine in cancer therapy
Fan, D., Cao, Y., Cao, M., Wang, Y., Cao, Y., & Gong, T. (2023) · Signal Transduction and Targeted Therapy · doi:10.1038/s41392-023-01536-y · Cited by 878
Metadata
- Authors
- Sontheimer-Phelps, A., Hassell, B. A., & Ingber, D. E.
- Affiliations
- Harvard University (US)
- Boston Children's Hospital (US)
- Corresponding author
- Ingber, Donald E.
- Venue
- Nature Reviews Cancer
- Published
- 2019-01-15
- Volume
- 19
- Issue
- 2
- Pages
- 65-81
- ISSN
- 1474-175X (ISSN-L)
- 1474-1768
- OpenAlex
- W2909633774
- Cited by
- 906
- References
- 122
- Citations by year
- 2026: 87 · 2025: 121 · 2024: 118 · 2023: 137 · 2022: 145 · 2021: 127 · 2020: 113 · 2019: 57
- FWCI
- 8.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Nature reviews. Cancer (publishedVersion)
- PubMed (publishedVersion)
- FreiDok plus (Universitätsbibliothek Freiburg) (submittedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Health Sciences › Medicine › Oncology › Cancer Cells and Metastasis
- Keywords
- organ-on-a-chip, microfluidic cell culture, cancer modelling, tumor microenvironment, tumor progression, anticancer drug development, personalized medicine, organoids, spheroids, biophysical cues, drug response
- MeSH terms
- Animals, Humans, Models, Biological, Neoplasms, Disease Progression, Microfluidics, Precision Medicine, Tumor Microenvironment
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.