The DOI matches its Crossref record; 103 of the 103 references it cites were found in a registry or an index.
Optical imaging techniques for point-of-care diagnostics
Open accessAbstract
Improving access to effective and affordable healthcare has long been a global endeavor. In this quest, the development of cost-effective and easy-to-use medical testing equipment that enables rapid and accurate diagnosis is essential to reduce the time and costs associated with healthcare services. To this end, point-of-care (POC) diagnostics plays a crucial role in healthcare delivery in both developed and developing countries by bringing medical testing to patients, or to sites near patients. As the diagnosis of a wide range of diseases, including various types of cancers and many endemics, relies on optical techniques, numerous compact and cost-effective optical imaging platforms have been developed in recent years for use at the POC. Here, we review the state-of-the-art optical imaging techniques that can have a significant impact on global health by facilitating effective and affordable POC diagnostics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Huang, D., Swanson, E. A., Lin, C. P., Schuman, J. S., Stinson, W. G., Chang, W., Hee, M. R., Flotte, T., Gregory, K., Puliafito, C. A., et al. (1991) · Science · doi:10.1126/science.1957169 · Cited by 13,788
Introduction to Fourier optics
Goodman, J. W. (1968) · Cited by 10,608
Introduction to Fourier Optics
Sutton, P. (1996) · Quantum and Semiclassical Optics: Journal of the European Optical Society Part B · doi:10.1088/1355-5111/8/5/014 · Cited by 4,934
Isolation of rare circulating tumour cells in cancer patients by microchip technology
Nagrath, S., Sequist, L. V., Maheswaran, S., Bell, D. W., Irimia, D., Ulkus, L., Smith, M. R., Kwak, E. L., Digumarthy, S., Muzikansky, A., et al. (2007) · Nature · doi:10.1038/nature06385 · Cited by 3,559
Super-resolution image reconstruction: a technical overview
Park, S. C., Park, M. K., & Kang, M. G. (2003) · IEEE Signal Processing Magazine · doi:10.1109/msp.2003.1203207 · Cited by 3,282
Optical Sectioning Deep Inside Live Embryos by Selective Plane Illumination Microscopy
Huisken, J., Swoger, J., Del Bene, F., Wittbrodt, J., & Stelzer, E. H. K. (2004) · Science · doi:10.1126/science.1100035 · Cited by 2,355
Microfluidic diagnostic technologies for global public health
Yager, P., Edwards, T., Fu, E., Helton, K., Nelson, K., Tam, M. R., & Weigl, B. H. (2006) · Nature · doi:10.1038/nature05064 · Cited by 1,979
Optical coherence tomography - principles and applications
Fercher, A. F., Drexler, W., Hitzenberger, C. K., & Lasser, T. (2003) · Reports on Progress in Physics · doi:10.1088/0034-4885/66/2/204 · Cited by 1,866
Functional photoacoustic microscopy for high-resolution and noninvasive in vivo imaging
Zhang, H. F., Maslov, K., Stoica, G., & Wang, L. V. (2006) · Nature Biotechnology · doi:10.1038/nbt1220 · Cited by 1,854
Reconstruction of an object from the modulus of its Fourier transform
Fienup, J. R. (1978) · Optics Letters · doi:10.1364/ol.3.000027 · Cited by 1,836
Lichtman, J. W., & Conchello, J.-A. (2005) · Nature Methods · doi:10.1038/nmeth817 · Cited by 1,742
Microfluidic devices fabricated in Poly(dimethylsiloxane) for biological studies
Sia, S. K., & Whitesides, G. M. (2003) · ELECTROPHORESIS · doi:10.1002/elps.200305584 · Cited by 1,717
Isolation of circulating tumor cells using a microvortex-generating herringbone-chip
Stott, S. L., Hsu, C.-H., Tsukrov, D. I., Yu, M., Miyamoto, D. T., Waltman, B. A., Rothenberg, S. M., Shah, A. M., Smas, M. E., Korir, G. K., et al. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1012539107 · Cited by 1,634
Reconstruction of Zebrafish Early Embryonic Development by Scanned Light Sheet Microscopy
Keller, P. J., Schmidt, A. D., Wittbrodt, J., & Stelzer, E. H. K. (2008) · Science · doi:10.1126/science.1162493 · Cited by 1,560
Electrochemical biosensors: Towards point-of-care cancer diagnostics
Wang, J. (2006) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2005.10.027 · Cited by 1,454
Martinez, A. W., Phillips, S. T., Carrilho, E., Thomas, S. W., Sindi, H., & Whitesides, G. M. (2008) · Analytical Chemistry · doi:10.1021/ac800112r · Cited by 1,443
In Vivo Endoscopic Optical Biopsy with Optical Coherence Tomography
Tearney, G. J., Brezinski, M. E., Bouma, B. E., Boppart, S. A., Pitris, C., Southern, J. F., & Fujimoto, J. G. (1997) · Science · doi:10.1126/science.276.5321.2037 · Cited by 1,364
de Boer, J. F., Cense, B., Park, B. H., Pierce, M. C., Tearney, G. J., & Bouma, B. E. (2003) · Optics Letters · doi:10.1364/ol.28.002067 · Cited by 1,250
Electrochemical Detection for Paper-Based Microfluidics
Dungchai, W., Chailapakul, O., & Henry, C. S. (2009) · Analytical Chemistry · doi:10.1021/ac9007573 · Cited by 1,224
Measurement of intraocular distances by backscattering spectral interferometry
Fercher, A. F., Hitzenberger, C. K., Kamp, G., & El-Zaiat, S. Y. (1995) · Optics Communications · doi:10.1016/0030-4018(95)00119-s · Cited by 1,212
Optical Projection Tomography as a Tool for 3D Microscopy and Gene Expression Studies
Sharpe, J., Ahlgren, U., Perry, P., Hill, B., Ross, A., Hecksher-Sørensen, J., Baldock, R., & Davidson, D. (2002) · Science · doi:10.1126/science.1068206 · Cited by 1,158
Commercialization of microfluidic point-of-care diagnostic devices
Chin, C. D., Linder, V., & Sia, S. K. (2012) · Lab on a Chip · doi:10.1039/c2lc21204h · Cited by 1,124
Miniaturized integration of a fluorescence microscope
Ghosh, K. K., Burns, L. D., Cocker, E. D., Nimmerjahn, A., Ziv, Y., Gamal, A. E., & Schnitzer, M. J. (2011) · Nature Methods · doi:10.1038/nmeth.1694 · Cited by 1,120
Memoir on inventing the confocal scanning microscope
Minsky, M. (1988) · Scanning · doi:10.1002/sca.4950100403 · Cited by 1,118
Point-of-Care Diagnostics for Global Health
Yager, P., Domingo, G. J., & Gerdes, J. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160524 · Cited by 1,076
Choi, W., Fang-Yen, C., Badizadegan, K., Oh, S., Lue, N., Dasari, R. R., & Feld, M. S. (2007) · Nature Methods · doi:10.1038/nmeth1078 · Cited by 955
State-of-the-art retinal optical coherence tomography
DREXLER, W., & FUJIMOTO, J. (2008) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2007.07.005 · Cited by 906
Optical biopsy and imaging using optical coherence tomography
Fujimoto, J. G., Brezinski, M. E., Tearney, G. J., Boppart, S. A., Bouma, B., Hee, M. R., Southern, J. F., & Swanson, E. A. (1995) · Nature Medicine · doi:10.1038/nm0995-970 · Cited by 887
Lab-on-a-chip devices for global health: Past studies and future opportunities
Chin, C. D., Linder, V., & Sia, S. K. (2007) · Lab Chip · doi:10.1039/b611455e · Cited by 811
Fluorescence versus conventional sputum smear microscopy for tuberculosis: a systematic review
Steingart, K. R., Henry, M., Ng, V., Hopewell, P. C., Ramsay, A., Cunningham, J., Urbanczik, R., Perkins, M., Aziz, M. A., & Pai, M. (2006) · The Lancet Infectious Diseases · doi:10.1016/s1473-3099(06)70578-3 · Cited by 798
Microfluidics-based diagnostics of infectious diseases in the developing world
Chin, C. D., Laksanasopin, T., Cheung, Y. K., Steinmiller, D., Linder, V., Parsa, H., Wang, J., Moore, H., Rouse, R., Umviligihozo, G., et al. (2011) · Nature Medicine · doi:10.1038/nm.2408 · Cited by 759
Mobile Phone Based Clinical Microscopy for Global Health Applications
Breslauer, D. N., Maamari, R. N., Switz, N. A., Lam, W. A., & Fletcher, D. A. (2009) · PLoS ONE · doi:10.1371/journal.pone.0006320 · Cited by 694
Point-of-care testing (POCT): Current techniques and future perspectives
Luppa, P. B., Müller, C., Schlichtiger, A., & Schlebusch, H. (2011) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2011.01.019 · Cited by 660
Optical Coherence Tomography for Optical Biopsy: Properties and Demonstration of Vascular Pathology
Brezinski, M. E., Tearney, G. J., Bouma, B. E., Izatt, J. A., Hee, M. R., Swanson, E. A., Southern, J. F., & Fujimoto, J. G. (1996) · Circulation · doi:10.1161/01.cir.93.6.1206 · Cited by 566
Optical coherence tomography: a review of clinical development from bench to bedside
Zysk, A. M., Nguyen, F. T., Oldenburg, A. L., Marks, D. L., & Boppart, S. A. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2793736 · Cited by 547
Imaging without lenses: achievements and remaining challenges of wide-field on-chip microscopy
Greenbaum, A., Luo, W., Su, T.-W., Göröcs, Z., Xue, L., Isikman, S. O., Coskun, A. F., Mudanyali, O., & Ozcan, A. (2012) · Nature Methods · doi:10.1038/nmeth.2114 · Cited by 540
Self-citationMudanyali, O., Tseng, D., Oh, C., Isikman, S. O., Sencan, I., Bishara, W., Oztoprak, C., Seo, S., Khademhosseini, B., & Ozcan, A. (2010) · Lab on a Chip · doi:10.1039/c000453g · Cited by 488
Self-citationLensfree microscopy on a cellphone
Tseng, D., Mudanyali, O., Oztoprak, C., Isikman, S. O., Sencan, I., Yaglidere, O., & Ozcan, A. (2010) · Lab on a Chip · doi:10.1039/c003477k · Cited by 480
Self-citationInnovations in optical microfluidic technologies for point-of-care diagnostics
Myers, F. B., & Lee, L. P. (2008) · Lab on a Chip · doi:10.1039/b812343h · Cited by 474
Liu, L., Gardecki, J. A., Nadkarni, S. K., Toussaint, J. D., Yagi, Y., Bouma, B. E., & Tearney, G. J. (2011) · Nature Medicine · doi:10.1038/nm.2409 · Cited by 463
Three-dimensional photoacoustic imaging of blood vessels in tissue
Hoelen, C. G. A., de Mul, F. F. M., Pongers, R., & Dekker, A. (1998) · Optics Letters · doi:10.1364/ol.23.000648 · Cited by 446
Lensfree on-chip microscopy over a wide field-of-view using pixel super-resolution
Bishara, W., Su, T.-W., Coskun, A. F., & Ozcan, A. (2010) · Optics Express · doi:10.1364/oe.18.011181 · Cited by 440
Self-citationIntegrated rapid-diagnostic-test reader platform on a cellphone
Mudanyali, O., Dimitrov, S., Sikora, U., Padmanabhan, S., Navruz, I., & Ozcan, A. (2012) · Lab on a Chip · doi:10.1039/c2lc40235a · Cited by 426
Self-citationTrends in miniaturized total analysis systems for point-of-care testing in clinical chemistry
Tüdős, A. J., Besselink, G. A. J., & Schasfoort, R. B. M. (2001) · Lab Chip · doi:10.1039/b106958f · Cited by 426
Phase retrieval from series of images obtained by defocus variation
Allen, L. J., & Oxley, M. P. (2001) · Optics Communications · doi:10.1016/s0030-4018(01)01556-5 · Cited by 423
Optofluidic Fluorescent Imaging Cytometry on a Cell Phone
Zhu, H., Mavandadi, S., Coskun, A. F., Yaglidere, O., & Ozcan, A. (2011) · Analytical Chemistry · doi:10.1021/ac201587a · Cited by 390
Self-citationMicrofluidic immunoassays as rapid saliva-based clinical diagnostics
Herr, A. E., Hatch, A. V., Throckmorton, D. J., Tran, H. M., Brennan, J. S., Giannobile, W. V., & Singh, A. K. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0607254104 · Cited by 389
High-speed, miniaturized fluorescence microscopy in freely moving mice
Flusberg, B. A., Nimmerjahn, A., Cocker, E. D., Mukamel, E. A., Barretto, R. P. J., Ko, T. H., Burns, L. D., Jung, J. C., & Schnitzer, M. J. (2008) · Nature Methods · doi:10.1038/nmeth.1256 · Cited by 385
Point-of-care biosensor systems for cancer diagnostics/prognostics
Soper, S. A., Brown, K., Ellington, A., Frazier, B., Garcia-Manero, G., Gau, V., Gutman, S. I., Hayes, D. F., Korte, B., Landers, J. L., et al. (2006) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2006.01.006 · Cited by 376
Gervais, L., & Delamarche, E. (2009) · Lab on a Chip · doi:10.1039/b906523g · Cited by 345
A microfluidic device for practical label-free CD4+ T cell counting of HIV-infected subjects
Cheng, X., Irimia, D., Dixon, M., Sekine, K., Demirci, U., Zamir, L., Tompkins, R. G., Rodriguez, W., & Toner, M. (2007) · Lab Chip · doi:10.1039/b612966h · Cited by 340
Cell-Phone-Based Platform for Biomedical Device Development and Education Applications
Smith, Z. J., Chu, K., Espenson, A. R., Rahimzadeh, M., Gryshuk, A., Molinaro, M., Dwyre, D. M., Lane, S., Matthews, D., & Wachsmann-Hogiu, S. (2011) · PLoS ONE · doi:10.1371/journal.pone.0017150 · Cited by 339
Cost-effective and compact wide-field fluorescent imaging on a cell-phone
Zhu, H., Yaglidere, O., Su, T.-W., Tseng, D., & Ozcan, A. (2011) · Lab Chip · doi:10.1039/c0lc00358a · Cited by 330
Self-citationBarnard, K. J. (1998) · Optical Engineering · doi:10.1117/1.601623 · Cited by 324
A review of practical techniques for the diagnosis of malaria
T. MAKLER C. J. PALMER A. L. AGER, M. (1998) · Annals of Tropical Medicine And Parasitology · doi:10.1080/00034989859401 · Cited by 301
Cancer imaging by optical coherence tomography: preclinical progress and clinical potential
Vakoc, B. J., Fukumura, D., Jain, R. K., & Bouma, B. E. (2012) · Nature Reviews Cancer · doi:10.1038/nrc3235 · Cited by 299
Holographic pixel super-resolution in portable lensless on-chip microscopy using a fiber-optic array
Bishara, W., Sikora, U., Mudanyali, O., Su, T.-W., Yaglidere, O., Luckhart, S., & Ozcan, A. (2011) · Lab on a Chip · doi:10.1039/c0lc00684j · Cited by 288
Self-citationMicrofluidics and point-of-care testing
Sia, S. K., & Kricka, L. J. (2008) · Lab on a Chip · doi:10.1039/b817915h · Cited by 279
Quantum dot enabled detection of Escherichia coli using a cell-phone
Zhu, H., Sikora, U., & Ozcan, A. (2012) · The Analyst · doi:10.1039/c2an35071h · Cited by 277
Self-citationLensless high-resolution on-chip optofluidic microscopes for Caenorhabditis elegans and cell imaging
Cui, X., Lee, L. M., Heng, X., Zhong, W., Sternberg, P. W., Psaltis, D., & Yang, C. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0804612105 · Cited by 277
A paper and plastic device for performing recombinase polymerase amplification of HIV DNA
Rohrman, B. A., & Richards-Kortum, R. R. (2012) · Lab on a Chip · doi:10.1039/c2lc40423k · Cited by 273
Confocal microscopy through a fiber-optic imaging bundle
Gmitro, A. F., & Aziz, D. (1993) · Optics Letters · doi:10.1364/ol.18.000565 · Cited by 266
Towards non- and minimally instrumented, microfluidics-based diagnostic devices
Weigl, B., Domingo, G., LaBarre, P., & Gerlach, J. (2008) · Lab on a Chip · doi:10.1039/b811314a · Cited by 259
Living specimen tomography by digital holographic microscopy: morphometry of testate amoeba
Charrière, F., Pavillon, N., Colomb, T., Depeursinge, C., Heger, T. J., Mitchell, E. A. D., Marquet, P., & Rappaz, B. (2006) · Optics Express · doi:10.1364/oe.14.007005 · Cited by 257
Perspective on Optical Biosensors and Integrated Sensor Systems
Ligler, F. S. (2009) · Analytical Chemistry · doi:10.1021/ac8016289 · Cited by 240
Greenbaum, A., & Ozcan, A. (2012) · Optics Express · doi:10.1364/oe.20.003129 · Cited by 225
Self-citationMicrofluidic diagnostics for the developing world
Mao, X., & Huang, T. J. (2012) · Lab on a Chip · doi:10.1039/c2lc90022j · Cited by 223
Lens-free optical tomographic microscope with a large imaging volume on a chip
Isikman, S. O., Bishara, W., Mavandadi, S., Yu, F. W., Feng, S., Lau, R., & Ozcan, A. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1015638108 · Cited by 216
Self-citationZheng, G., Lee, S. A., Antebi, Y., Elowitz, M. B., & Yang, C. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1110681108 · Cited by 209
Point-of-care testing of proteins
Warsinke, A. (2009) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-008-2572-0 · Cited by 173
Handheld Optical Coherence Tomography Scanner for Primary Care Diagnostics
Jung, W., Kim, J., Jeon, M., Chaney, E. J., Stewart, C. N., & Boppart, S. A. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2096816 · Cited by 162
Detection of waterborne parasites using field-portable and cost-effective lensfree microscopy
Mudanyali, O., Oztoprak, C., Tseng, D. K., Erlinger, A., & Özcan, A. (2010) · Lab on a Chip · doi:10.1039/c004829a · Cited by 158
Self-citationHigh-Throughput Lens-Free Blood Analysis on a Chip
Seo, S., Isikman, S. O., Şencan, İ., Mudanyali, O., Su, T., Bishara, W., Erlinger, A., & Özcan, A. (2010) · Analytical Chemistry · doi:10.1021/ac1007915 · Cited by 153
Self-citationHolographic microscopy and diffractive microtomography of transparent samples
Debailleul, M., Simon, B., Georges, V., Haeberlé, O., & Lauer, V. (2008) · Measurement Science and Technology · doi:10.1088/0957-0233/19/7/074009 · Cited by 152
Holographic opto-fluidic microscopy
Bishara, W., Zhu, H., & Özcan, A. (2010) · Optics Express · doi:10.1364/oe.18.027499 · Cited by 149
Self-citationDaaboul, G. G., Yurt, A., Zhang, X., Hwang, G. M., Goldberg, B. B., & Ünlü, M. S. (2010) · Nano Letters · doi:10.1021/nl103210p · Cited by 145
Three-dimensional imaging of single isolated cell nuclei using optical projection tomography
Fauver, M. E., Seibel, E. J., Rahn, J. R., Meyer, M. G., Patten, F. W., Neumann, T., & Nelson, A. C. (2005) · Optics Express · doi:10.1364/opex.13.004210 · Cited by 143
Chemical Typing of Amyloid Protein Contained in Formalin-Fixed Paraffin-Embedded Biopsy Specimens
Murphy, C. L., Eulitz, M., Hrncic, R., Sletten, K., Westermark, P., Williams, T. K., Macy, S. D., Wooliver, C., Wall, J. S., Weiss, D. T., et al. (2001) · American Journal of Clinical Pathology · doi:10.1309/twbm-8l4e-vk22-frh5 · Cited by 143
Sub-pixel resolving optofluidic microscope for on-chip cell imaging
Zheng, G., Lee, S. A., Yang, S., & Yang, C. (2010) · Lab on a Chip · doi:10.1039/c0lc00213e · Cited by 136
In vivo imaging of oral neoplasia using a miniaturized fiber optic confocal reflectance microscope
Maitland, K. C., Gillenwater, A. M., Williams, M. D., El‐Naggar, A. K., Descour, M. R., & Richards-Kortum, R. R. (2008) · Oral Oncology · doi:10.1016/j.oraloncology.2008.02.002 · Cited by 118
Multiplexed Detection of Bacteria and Toxins Using a Microflow Cytometer
Kim, J. S., Anderson, G. P., Erickson, J. S., Golden, J. P., Nasir, M., & Ligler, F. S. (2009) · Analytical Chemistry · doi:10.1021/ac9005827 · Cited by 108
Gradient-index fiber-optic microprobes for minimally invasive in vivo low-coherence interferometry
Reed, W. A., Yan, M. F., & Schnitzer, M. J. (2002) · Optics Letters · doi:10.1364/ol.27.001794 · Cited by 107
High-resolution three-dimensional imaging of biofilm development using optical coherence tomography
Xi, C., Marks, D. L., Schlachter, S., Luo, W., & Boppart, S. A. (2006) · Journal of Biomedical Optics · doi:10.1117/1.2209962 · Cited by 106
Portable, Battery-Operated, Low-Cost, Bright Field and Fluorescence Microscope
Miller, A. R., Davis, G. L., Oden, Z. M., Razavi, M. R., Fateh, A., Ghazanfari, M., Abdolrahimi, F., Dizaji, S. P., Sakhaie, F., Olsen, R. J., et al. (2010) · PLoS ONE · doi:10.1371/journal.pone.0011890 · Cited by 97
A cell-based biosensor for real-time detection of cardiotoxicity using lensfree imaging
Kim, S. B., Bae, H., Cha, J. M., Moon, S. J., Dokmeci, M. R., Cropek, D. M., & Khademhosseini, A. (2011) · Lab on a Chip · doi:10.1039/c1lc20098d · Cited by 96
Field-portable lensfree tomographic microscope
Isikman, S. O., Bishara, W., Sikora, U., Yaglidere, O., Yeah, J., & Özcan, A. (2011) · Lab on a Chip · doi:10.1039/c1lc20127a · Cited by 87
Self-citationOn-chip differential interference contrast microscopy using lensless digital holography
Oh, C., Isikman, S. O., Khademhosseinieh, B., & Özcan, A. (2010) · Optics Express · doi:10.1364/oe.18.004717 · Cited by 85
Self-citationRoda, A., Mirasoli, M., Dolci, L. S., Buragina, A., Bonvicini, F., Simoni, P., & Guardigli, M. (2011) · Analytical Chemistry · doi:10.1021/ac200360k · Cited by 85
Tomographic Phase Microscopy: Quantitative 3D-Mapping of Refractive Index in Live Cells
Choi, W., Fang-Yen, C. M., Oh, S., Lue, N., Dasari, R. R., Feld, M. S., & Badizadegan, K. (2008) · Imaging & Microscopy · doi:10.1002/imic.200890018 · Cited by 83
Video-rate compressive holographic microscopic tomography
Hahn, J., Lim, S., Choi, K., et al. (2011) · Optics Express · doi:10.1364/oe.19.007289 · Cited by 82
Lee, S. A., Leitao, R. M., Zheng, G., Yang, S., Rodríguez, A., & Yang, C. (2011) · PLoS ONE · doi:10.1371/journal.pone.0026127 · Cited by 75
Shin, D., Pierce, M. C., Gillenwater, A. M., Williams, M. D., & Richards-Kortum, R. R. (2010) · PLoS ONE · doi:10.1371/journal.pone.0011218 · Cited by 71
Microfluidics at the crossroad with point-of-care diagnostics
Linder, V. (2007) · The Analyst · doi:10.1039/b706347d · Cited by 70
In vivo imaging of ovarian tissue using a novel confocal microlaparoscope
Tanbakuchi, A. A., Udovich, J. A., Rouse, A. R., et al. (2009) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2009.07.027 · Cited by 69
Lensfree super-resolution holographic microscopy using wetting films on a chip
Mudanyali, O., Bishara, W., & Özcan, A. (2011) · Optics Express · doi:10.1364/oe.19.017378 · Cited by 59
Self-citationBacteria detection with thin wetting film lensless imaging
Allier, C. P., Hiernard, G., Poher, V., & Dinten, J. (2010) · Biomedical Optics Express · doi:10.1364/boe.1.000762 · Cited by 52
Integrated microfluidic array plate (iMAP) for cellular and molecular analysis
Dimov, I. K., Kijanka, G. S., Park, Y., Ducrée, J., Kang, T., & Lee, L. P. (2011) · Lab on a Chip · doi:10.1039/c1lc20105k · Cited by 49
Programmable Nano-Bio-Chips: Multifunctional Clinical Tools for Use at The Point-Of-Care
Jokerst, J. V., & McDevitt, J. T. (2009) · Nanomedicine · doi:10.2217/nnm.09.94 · Cited by 44
A fluorescence lifetime imaging scanning confocal endomicroscope
Kennedy, G. T., Manning, H. B., Elson, D. S., Neil, M. A. A., Stamp, G., Viellerobe, B., Lacombe, F., Dunsby, C. W., & French, P. M. W. (2009) · Journal of Biophotonics · doi:10.1002/jbio.200910065 · Cited by 43
Quantitative Detection of Bioassays with a Low‐Cost Image‐Sensor Array for Integrated Microsystems
Vykoukal, D. M., Stone, G. P., Gascoyne, P. R. C., Alt, E., & Vykoukal, J. (2009) · Angewandte Chemie International Edition · doi:10.1002/anie.200901814 · Cited by 28
Toward a low-cost compact array microscopy platform for detection of tuberculosis
McCall, B., Pierce, M. C., Graviss, E. A., Richards-Kortum, R. R., & Tkaczyk, T. (2011) · Tuberculosis · doi:10.1016/j.tube.2011.10.011 · Cited by 21
Kuck, M., Schanzer, S., Meinke, M. C., et al. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.17.10.101504 · Cited by 12
Quality in point-of-care testing: taking POC to the next level
Nichols, J. H. (2006) · Accreditation and Quality Assurance · doi:10.1007/s00769-006-0130-z · Cited by 5
Cited by
Critical review on biofilm methods
Azeredo, J., Azevedo, N. F., Briandet, R., Cerca, N., Coenye, T., Costa, A. R., Desvaux, M., Di Bonaventura, G., Hébraud, M., Jaglic, Z., et al. (2017) · Critical Reviews in Microbiology · doi:10.1080/1040841x.2016.1208146 · Cited by 1,045
Advances in paper-based point-of-care diagnostics
Hu, J., Wang, S., Wang, L., Li, F., Pingguan-Murphy, B., Lu, T. J., & Xu, F. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.10.075 · Cited by 956
Yamada, K., Shibata, H., Suzuki, K., & Citterio, D. (2017) · Lab on a Chip · doi:10.1039/c6lc01577h · Cited by 437
Foldscope: Origami-Based Paper Microscope
Cybulski, J. S., Clements, J., & Prakash, M. (2014) · PLoS ONE · doi:10.1371/journal.pone.0098781 · Cited by 388
Zangheri, M., Cevenini, L., Anfossi, L., Baggiani, C., Simoni, P., Di Nardo, F., & Roda, A. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.08.048 · Cited by 373
Metadata
- Authors
- Zhu, H., Isikman, S. O., Mudanyali, O., Greenbaum, A., & Ozcan, A.
- Venue
- Lab Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2013
- Volume
- 13
- Issue
- 1
- Pages
- 51-67
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2063453644
- Cited by
- 364
- References
- 103
- FWCI
- 19.36
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.