The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Energy-selective reconstructions in X-ray computerised tomography
Open accessAbstract
All X-ray computerized tomography systems that are available or proposed base their reconstructions on measurements that integrate over energy. X-ray tubes produce a broad spectrum of photon energies and a great deal of information can be derived by measuring changes in the transmitted spectrum. We show that for any material, complete energy spectral information may be summarized by a few constants which are independent of energy. A technique is presented which uses simple, low-resolution, energy spectrum measurements and conventional computerized tomography techniques to calculate these constants at every point within a cross-section of an object. For comparable accuracy, patient dose is shown to be approximately the same as that produced by conventional systems. Possible uses of energy spectral information for diagnosis are presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Detection, Estimation, And Modulation Theory
Trees, H. L. V. (1968) · Cited by 5,969
Phelps, M. E., Hoffman, E. J., & Ter‐Pogossian, M. M. (1975) · Radiology · doi:10.1148/117.3.573 · Cited by 145
Cited by
Dual- and Multi-Energy CT: Principles, Technical Approaches, and Clinical Applications
McCollough, C. H., Leng, S., Yu, L., & Fletcher, J. G. (2015) · Radiology · doi:10.1148/radiol.2015142631 · Cited by 1,598
Photon-counting CT: Technical Principles and Clinical Prospects
Willemink, M. J., Persson, M., Pourmorteza, A., Pelc, N. J., & Fleischmann, D. (2018) · Radiology · doi:10.1148/radiol.2018172656 · Cited by 1,326
Vision 20/20: Single photon counting x‐ray detectors in medical imaging
Taguchi, K., & Iwanczyk, J. S. (2013) · Medical Physics · doi:10.1118/1.4820371 · Cited by 948
Attenuation correction for a combined 3D PET/CT scanner
Kinahan, P. E., Townsend, D. W., Beyer, T., & Sashin, D. (1998) · Medical Physics · doi:10.1118/1.598392 · Cited by 946
CT artifacts: causes and reduction techniques
Boas, F. E., & Fleischmann, D. (2012) · Imaging in Medicine · doi:10.2217/iim.12.13 · Cited by 848
Schlomka, J. P., Roessl, E., Dorscheid, R., Dill, S., Martens, G., Istel, T., Bäumer, C., Herrmann, C., Steadman, R., Zeitler, G., et al. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/15/002 · Cited by 801
Statistical image reconstruction for polyenergetic X-ray computed tomography
Elbakri, I. A., & Fessler, J. A. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/42.993128 · Cited by 691
Dual-Energy CT–Based Monochromatic Imaging
Yu, L., Leng, S., & McCollough, C. H. (2012) · American Journal of Roentgenology · doi:10.2214/ajr.12.9121 · Cited by 609
Willemink, M. J., & Noël, P. B. (2019) · European Radiology · doi:10.1007/s00330-018-5810-7 · Cited by 603
K-edge imaging in x-ray computed tomography using multi-bin photon counting detectors
Roessl, E., & Proksa, R. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/15/020 · Cited by 558
Penalized weighted least-squares image reconstruction for dual energy X-ray transmission tomography
Sukovic, P., & Clinthorne, N. H. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.896783 · Cited by 552
X-ray-based attenuation correction for positron emission tomography/computed tomography scanners
Kinahan, P. E., Hasegawa, B. H., & Beyer, T. (2003) · Seminars in Nuclear Medicine · doi:10.1053/snuc.2003.127307 · Cited by 515
Atherosclerotic Plaque Composition: Analysis with Multicolor CT and Targeted Gold Nanoparticles
Cormode, D. P., Roessl, E., Thran, A., Skajaa, T., Gordon, R. E., Schlomka, J.-P., Fuster, V., Fisher, E. A., Mulder, W. J. M., Proksa, R., et al. (2010) · Radiology · doi:10.1148/radiol.10092473 · Cited by 479
An iterative maximum-likelihood polychromatic algorithm for CT
De Man, B., Nuyts, J., Dupont, P., Marchal, G., & Suetens, P. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.959297 · Cited by 430
Radiation dose reduction in computed tomography: techniques and future perspective
Yu, L., Liu, X., Leng, S., Kofler, J. M., Ramirez-Giraldo, J. C., Qu, M., Christner, J., Fletcher, J. G., & McCollough, C. H. (2009) · Imaging in Medicine · doi:10.2217/iim.09.5 · Cited by 395
Vaquero, J. J., & Kinahan, P. (2015) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071114-040723 · Cited by 383
State of the Art: Dual-Energy CT of the Abdomen
Marin, D., Boll, D. T., Mileto, A., & Nelson, R. C. (2014) · Radiology · doi:10.1148/radiol.14131480 · Cited by 368
Nanoparticle contrast agents for computed tomography: a focus on micelles
Cormode, D. P., Naha, P. C., & Fayad, Z. A. (2014) · Contrast Media & Molecular Imaging · doi:10.1002/cmmi.1551 · Cited by 362
Dual-Energy (Spectral) CT: Applications in Abdominal Imaging
Silva, A. C., Morse, B. G., Hara, A. K., Paden, R. G., Hongo, N., & Pavlicek, W. (2011) · RadioGraphics · doi:10.1148/rg.314105159 · Cited by 351
Virtual monochromatic imaging in dual‐source dual‐energy CT: Radiation dose and image quality
Yu, L., Christner, J. A., Leng, S., Wang, J., Fletcher, J. G., & McCollough, C. H. (2011) · Medical Physics · doi:10.1118/1.3658568 · Cited by 343
An outlook on x‐ray CT research and development
Wang, G., Yu, H., & De Man, B. (2008) · Medical Physics · doi:10.1118/1.2836950 · Cited by 341
Material Separation Using Dual-Energy CT: Current and Emerging Applications
Patino, M., Prochowski, A., Agrawal, M. D., Simeone, F. J., Gupta, R., Hahn, P. F., & Sahani, D. V. (2016) · RadioGraphics · doi:10.1148/rg.2016150220 · Cited by 328
Primak, A. N., Ramirez Giraldo, J. C., Liu, X., Yu, L., & McCollough, C. H. (2009) · Medical Physics · doi:10.1118/1.3083567 · Cited by 318
Detector-based spectral CT with a novel dual-layer technology: principles and applications
Rassouli, N., Etesami, M., Dhanantwari, A., & Rajiah, P. (2017) · Insights into Imaging · doi:10.1007/s13244-017-0571-4 · Cited by 300
Pache, G., Krauss, B., Strohm, P., Saueressig, U., Blanke, P., Bulla, S., Schäfer, O., Helwig, P., Kotter, E., Langer, M., et al. (2010) · Radiology · doi:10.1148/radiol.10091230 · Cited by 281
Method for transforming CT images for attenuation correction in PET/CT imaging
Carney, J. P. J., Townsend, D. W., Rappoport, V., & Bendriem, B. (2006) · Medical Physics · doi:10.1118/1.2174132 · Cited by 271
Computerized tomography with X-ray, emission, and ultrasound sources
Kak, A. C. (1979) · Proceedings of the IEEE · doi:10.1109/proc.1979.11440 · Cited by 264
A review of X-ray explosives detection techniques for checked baggage
Wells, K., & Bradley, D. A. (2012) · Applied Radiation and Isotopes · doi:10.1016/j.apradiso.2012.01.011 · Cited by 259
Quantitative analysis of reservoir rocks by microfocus X-ray computerised tomography
Van Geet, M., Swennen, R., & Wevers, M. (2000) · Sedimentary Geology · doi:10.1016/s0037-0738(99)00127-x · Cited by 253
van Hamersvelt, R. W., Schilham, A. M. R., Engelke, K., den Harder, A. M., de Keizer, B., Verhaar, H. J., Leiner, T., de Jong, P. A., & Willemink, M. J. (2017) · European Radiology · doi:10.1007/s00330-017-4801-4 · Cited by 94
Badea, C. T., Clark, D. P., Holbrook, M., Srivastava, M., Mowery, Y., & Ghaghada, K. B. (2019) · Physics in Medicine & Biology · doi:10.1088/1361-6560/ab03e2 · Cited by 74
Li, X., Li, X., Li, J., Jiao, X., Jia, X., Zhang, X., Fan, G., Yang, J., & Guo, J. (2020) · Clinical Radiology · doi:10.1016/j.crad.2019.11.008 · Cited by 41
DXA-equivalent quantification of bone mineral density using dual-layer spectral CT scout scans
Laugerette, A., Schwaiger, B. J., Brown, K., Frerking, L. C., Kopp, F. K., Mei, K., Sellerer, T., Kirschke, J., Baum, T., Gersing, A. S., et al. (2019) · European Radiology · doi:10.1007/s00330-019-6005-6 · Cited by 29
Metadata
- Authors
- Alvarez, R. E., & Macovski, A.
- Venue
- Physics in Medicine & Biology
- Publisher
- IOP Publishing
- Published
- 1976-09-01
- Volume
- 21
- Issue
- 5
- Pages
- 733-744
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W1972037630
- Cited by
- 2,013
- References
- 2
- FWCI
- 9.26
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.