The DOI matches its Crossref record; 69 of the 69 references it cites were found in a registry or an index.
Review of piezoelectric micromachined ultrasonic transducers and their applications
Abstract
In recent decades, micromachined ultrasonic transducers (MUTs) have been investigated as an alternative to conventional piezocomposite ultrasonic transducers, primarily due to the advantages that microelectromechanical systems provide. Miniaturized ultrasonic systems require ultrasonic transducers integrated with complementary metal-oxide-semiconductor circuits. Hence, piezoelectric MUTs (pMUTs) and capacitive MUTs (cMUTs) have been developed as the most favorable solutions. This paper reviews the basic equations to understand the characteristics of thin-film-based piezoelectric devices and presents recent research on pMUTs, including current approaches and limitations. Methods to improve the coupling coefficient of pMUTs are also investigated, such as device structure, materials, and fabrication techniques. The device structure improvements include multielectrode pMUTs, partially clamped boundary conditions, and 3D pMUTs (curved and domed types), where the latter can provide an electromechanical coupling coefficient of up to 45%. The piezoelectric coefficient ( e 31 ) can be increased by controlling the crystal texture (seed layer of γ -Al 2 O 3 ), using single-crystal (PMN-PT) materials, or control of residual stresses (using SiO 2 layer). Arrays of pMUTs can be implemented for various applications including intravascular ultrasound, fingerprint sensors, rangefinders in air, and wireless power supply systems. pMUTs are expected to be an ideal solution for applications such as mobile biometric security (fingerprint sensors) and rangefinders due to their superior power efficiency and compact size.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Internet of Things (IoT): A vision, architectural elements, and future directions
Gubbi, J., Buyya, R., Marusic, S., & Palaniswami, M. (2013) · Future Generation Computer Systems · doi:10.1016/j.future.2013.01.010 · Cited by 12,293
Piezoelectric Nanogenerators Based on Zinc Oxide Nanowire Arrays
Wang, Z. L., & Song, J. (2006) · Science · doi:10.1126/science.1124005 · Cited by 7,922 · cited 1×
“3 GPa), but has the ability to form ZnO nanowires that can produce highly sensitive sensors and nanogenerators [22].”
BackgroundFerroelectric thin films: Review of materials, properties, and applications
Setter, N., Damjanovic, D., Eng, L., Fox, G., Gevorgian, S., Hong, S., Kingon, A., Kohlstedt, H., Park, N. Y., Stephenson, G. B., et al. (2006) · Journal of Applied Physics · doi:10.1063/1.2336999 · Cited by 1,907
Physical properties of tissue : a comprehensive reference book
Duck, F. A. (1990) · Cited by 1,675
Thin Film Piezoelectrics for MEMS
Trolier-McKinstry, S., & Muralt, P. (2004) · Journal of Electroceramics · doi:10.1023/b:jecr.0000033998.72845.51 · Cited by 1,023
Microelectromechanical systems (MEMS): fabrication, design and applications
Judy, J. W. (2001) · Smart Materials and Structures · doi:10.1088/0964-1726/10/6/301 · Cited by 828
Hwang, G., Park, H., Lee, J., Oh, S., Park, K., Byun, M., Park, H., Ahn, G., Jeong, C. K., No, K., et al. (2014) · Advanced Materials · doi:10.1002/adma.201400562 · Cited by 672
Phase transitions in the Pb (Zn 1/3 Nb 2/3 )O 3 -PbTiO 3 system
Kuwata, J., Uchino, K., & Nomura, S. (1981) · Ferroelectrics · doi:10.1080/00150198108223490 · Cited by 625
Measurement of piezoelectric coefficients of ferroelectric thin films
Lefki, K., & Dormans, G. J. M. (1994) · Journal of Applied Physics · doi:10.1063/1.357693 · Cited by 593
Piezoelectric MEMS sensors: state-of-the-art and perspectives
Tadigadapa, S., & Mateti, K. (2009) · Measurement Science and Technology · doi:10.1088/0957-0233/20/9/092001 · Cited by 581
Surface micromachined capacitive ultrasonic transducers
Ladabaum, I., Jin, X., Soh, H. T., Atalar, A., & Khuri-Yakub, B. T. (1998) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/58.677612 · Cited by 581
Shrout, T. R., Chang, Z. P., Kim, N., & Markgraf, S. (1990) · Ferroelectrics Letters Section · doi:10.1080/07315179008201118 · Cited by 532
Xu, F., Trolier-McKinstry, S., Ren, W., Xu, B., Xie, Z.-L., & Hemker, K. J. (2001) · Journal of Applied Physics · doi:10.1063/1.1325005 · Cited by 528
High-speed ultrasound volumetric imaging system. I. Transducer design and beam steering
Smith, S. W., Pavy, H. G., & von Ramm, O. T. (1991) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.68466 · Cited by 504
Ferroelectricity in thin perovskite films
Tybell, T., Ahn, C. H., & Triscone, J.-M. (1999) · Applied Physics Letters · doi:10.1063/1.124536 · Cited by 461
Dubois, M.-A., & Muralt, P. (1999) · Applied Physics Letters · doi:10.1063/1.124055 · Cited by 436
Cheng, J. M., Garcia-Garcia, H. M., de Boer, S. P. M., Kardys, I., Heo, J. H., Akkerhuis, K. M., Oemrawsingh, R. M., van Domburg, R. T., Ligthart, J., Witberg, K. T., et al. (2014) · European Heart Journal · doi:10.1093/eurheartj/eht484 · Cited by 379
Piezoelectric films for high frequency ultrasonic transducers in biomedical applications
Zhou, Q., Lau, S., Wu, D., & Kirk Shung, K. (2011) · Progress in Materials Science · doi:10.1016/j.pmatsci.2010.09.001 · Cited by 377
PZT thin films for microsensors and actuators: Where do we stand?
Muralt, P. (2000) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.852073 · Cited by 375
Flexible Piezoelectric PMN–PT Nanowire-Based Nanocomposite and Device
Xu, S., Yeh, Y.-W., Poirier, G., McAlpine, M. C., Register, R. A., & Yao, N. (2013) · Nano Letters · doi:10.1021/nl400169t · Cited by 339
Piezoelectric micromachined ultrasonic transducers based on PZT thin films
Muralt, P., Ledermann, N., Paborowski, J., Barzegar, A., Gentil, S., Belgacem, B., Petitgrand, S., Bosseboeuf, A., & Setter, N. (2005) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2005.1563270 · Cited by 332
Capacitive micromachined ultrasonic transducers for medical imaging and therapy
Khuri-Yakub, B. T., & Oralkan, Ö. (2011) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/21/5/054004 · Cited by 332
A review of calibration techniques for freehand 3-D ultrasound systems
Mercier, L., Langø, T., Lindseth, F., & Collins, D. L. (2005) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2004.11.015 · Cited by 326
Feedback Analysis and Design of RF Power Links for Low-Power Bionic Systems
Baker, M. W., & Sarpeshkar, R. (2007) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2007.893180 · Cited by 317
Eom, C.-B., & Trolier-McKinstry, S. (2012) · MRS Bulletin · doi:10.1557/mrs.2012.273 · Cited by 316
Ultra-wide bandwidth piezoelectric energy harvesting
Hajati, A., & Kim, S.-G. (2011) · Applied Physics Letters · doi:10.1063/1.3629551 · Cited by 296
Wells, P. N. T. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/13/r06 · Cited by 287
Development of piezoelectric micromachined ultrasonic transducers
Akasheh, F., Myers, T., Fraser, J. D., Bose, S., & Bandyopadhyay, A. (2004) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2003.11.022 · Cited by 253
Integration of 2D CMUT arrays with front-end electronics for volumetric ultrasound imaging
Wygant, I. O., Zhuang, X., Yeh, D. T., Oralkan, O., Ergun, A. S., Karaman, M., & Khuri-Yakub, B. T. (2008) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2008.652 · Cited by 248
Integrated power harvesting system including a MEMS generator and a power management circuit
Marzencki, M., Ammar, Y., & Basrour, S. (2008) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2007.10.073 · Cited by 246
Lu, Y., Tang, H., Fung, S., Wang, Q., Tsai, J. M., Daneman, M., Boser, B. E., & Horsley, D. A. (2015) · Applied Physics Letters · doi:10.1063/1.4922915 · Cited by 244
Piezoelectric actuation of PZT thin-film diaphragms at static and resonant conditions
Muralt, P., Kholkin, A. L., Köhli, M., & Maeder, T. (1996) · Sensors and Actuators A Physical · doi:10.1016/0924-4247(96)01139-9 · Cited by 212
Combining multiple matchers for a high security fingerprint verification system
Jain, A. K., Prabhakar, S., & Chen, S. (1999) · Pattern Recognition Letters · doi:10.1016/s0167-8655(99)00108-7 · Cited by 208
In-Air Rangefinding With an AlN Piezoelectric Micromachined Ultrasound Transducer
Przybyla, R. J., Shelton, S. E., Guedes, A., Izyumin, I. I., Kline, M. H., Horsley, D. A., & Boser, B. E. (2011) · IEEE Sensors Journal · doi:10.1109/jsen.2011.2157490 · Cited by 198
(1996) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.1996.535477 · Cited by 196
In situ deposition of epitaxial PbZrxTi(1−x)O3 thin films by pulsed laser deposition
Horwitz, J. S., Grabowski, K. S., Chrisey, D. B., & Leuchtner, R. E. (1991) · Applied Physics Letters · doi:10.1063/1.106284 · Cited by 186
Temperature-compensated aluminum nitride lamb wave resonators
Lin, C.-M., Yen, T.-T., Lai, Y.-J., Felmetsger, V. V., Hopcroft, M. A., Kuypers, J. H., & Pisano, A. P. (2010) · IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control · doi:10.1109/tuffc.2010.1443 · Cited by 182
A review of calibration techniques for freehand 3-D ultrasound systems
Mercier, L., Langø, T., Lindseth, F., & Collins, D. L. (2005) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2004.11.001 · Cited by 166
Piezoelectric thin films for mems
Muralt, P. (1997) · Integrated Ferroelectrics · doi:10.1080/10584589708013004 · Cited by 165
Piezoelectric thin films for MEMS
Kanno, I., Ouyang, J., Akedo, J., Yoshimura, T., Malič, B., & Muralt, P. (2023) · Applied Physics Letters · doi:10.1063/5.0146681 · Cited by 155
High security Iris verification system based on random secret integration
Chin, C. S., Teoh, A. B. J., & Ling, D. N. C. (2006) · Computer Vision and Image Understanding · doi:10.1016/j.cviu.2006.01.002 · Cited by 143
Three-dimensional micro electromechanical system piezoelectric ultrasound transducer
Hajati, A., Latev, D., Gardner, D., Hajati, A., Imai, D., Torrey, M., & Schoeppler, M. W. (2012) · Applied Physics Letters · doi:10.1063/1.4772469 · Cited by 137
Smyth, K. M., & Kim, S. (2015) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2014.006725 · Cited by 125
Optimization of electromechanical coupling for a thin-film PZT membrane: II. Experiment
Cho, J., Anderson, M. C., Richards, R. F., Bahr, D. F., & Richards, C. D. (2005) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/15/10/003 · Cited by 124
In vivo real-time 3-D intracardiac echo using PMUT arrays
Dausch, D. E., Gilchrist, K. H., Carlson, J. B., Hall, S. D., Castellucci, J. B., & von Ramm, O. T. (2014) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2014.006452 · Cited by 118
Spanu, A., Pinna, L., Viola, F. A., Seminara, L., Valle, M., Bonfiglio, A., & Cosseddu, P. (2016) · Organic Electronics · doi:10.1016/j.orgel.2016.05.034 · Cited by 99
Optimization of electromechanical coupling for a thin-film PZT membrane: I. Modeling
Cho, J., Anderson, M. C., Richards, R. F., Bahr, D. F., & Richards, C. D. (2005) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/15/10/002 · Cited by 94
Wang, T., & Lee, C. (2015) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2015.2472958 · Cited by 92
Tang, G., Yang, B. T., Liu, J., Xu, B., Zhu, H., & Yang, C. (2013) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2013.11.007 · Cited by 82
Inductive and Ultrasonic Multi-Tier Interface for Low-Power, Deeply Implantable Medical Devices
Sanni, A., Vilches, A., & Toumazou, C. (2012) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2011.2175390 · Cited by 75
Jung, J., Kim, S., Lee, W., & Choi, H. (2013) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/23/12/125037 · Cited by 74
Self-citationSammoura, F., Smyth, K. M., & Kim, S. (2012) · Ultrasonics · doi:10.1016/j.ultras.2012.06.015 · Cited by 73
Highly responsive curved aluminum nitride pMUT
Akhbari, S., Sammoura, F., Shelton, S. E., Chen, Y., Horsley, D. A., & Lin, L. (2014) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/memsys.2014.6765589 · Cited by 71
Akhbari, S., Sammoura, F., & Lin, L. (2016) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2016.2525802 · Cited by 64
POSFET tactile sensing arrays using CMOS technology
Dahiya, R., Adami, A., Collini, C., & Lorenzelli, L. (2013) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2013.02.007 · Cited by 64
Development of Biometric DNA Ink for Authentication Security
Hashiyada, M. (2004) · The Tohoku Journal of Experimental Medicine · doi:10.1620/tjem.204.109 · Cited by 63
Wang, M., Zhou, Y., & Randles, A. B. (2016) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2016.2577038 · Cited by 52
Han, G., Ryu, J., Yoon, W., Choi, J., Hahn, B., & Park, D.-S. (2011) · Journal of the American Ceramic Society · doi:10.1111/j.1551-2916.2010.04276.x · Cited by 50
Self-citationMicromachining for improvement of integrated ultrasonic transducer sensitivity
Mo, J.-H., Robinson, A. L., Fitting, D. W., Terry, F. L., & Carson, P. L. (1990) · IEEE Transactions on Electron Devices · doi:10.1109/16.43810 · Cited by 48
Fabrication of MEMS ZnO dome-shaped-diaphragm transducers for high-frequency ultrasonic imaging
Feng, G., Sharp, C. C., Zhou, Q., Pang, W., Kim, E. S., & Shung, K. K. (2005) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/15/3/021 · Cited by 47
He, Q. P., Liu, J., Yang, B. T., Wang, X., Chen, X. C., & Yang, C. (2014) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2014.07.008 · Cited by 44
POSFET tactile sensing chips using CMOS technology
Dahiya, R., Adami, A., Collini, C., Valle, M., & Lorenzelli, L. (2013) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/icsens.2013.6688149 · Cited by 43
Monolithic MEMS-CMOS ultrasonic rangefinder based on dual-electrode PMUTs
Rozen, O., Block, S. T., Mo, X., Bland, W., Hurst, P. J., Tsai, J. M.-L., Daneman, M., Amirtharajah, R., & Horsley, D. A. (2016) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/memsys.2016.7421571 · Cited by 40
Sammoura, F., Akhbari, S., & Lin, L. (2014) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2014.3067 · Cited by 39
Review of finger print sensing technologies
Memon, S. A., Sepasian, M., & Balachandran, W. (2008) · IEEE International Multitopic Conference (INMIC) · doi:10.1109/inmic.2008.4777740 · Cited by 35
A two-port piezoelectric micromachined ultrasonic transducer
Sammoura, F., Shelton, S. E., Akhbari, S., Horsley, D. A., & Lin, L. (2014) · IEEE International Symposium on Applications of Ferroelectrics (ISAF) · doi:10.1109/isaf.2014.6923004 · Cited by 29
Choi, H., Ding, J., Bandyopadhyay, A. K., Anderson, M. J., & Bose, S. (2008) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/18/2/025037 · Cited by 29
Self-citationAn integrated piezoelectric zinc oxide nanowire micro-energy harvester
Li, Y., Çelik‐Butler, Z., & Butler, D. P. (2016) · Nano Energy · doi:10.1016/j.nanoen.2016.05.008 · Cited by 26
Ferroelectric materials for thin-film and membrane resonators
Ballato, A. D., Gualtieri, J. G., & KOSINSKI, J. A. (2002) · IEEE International Symposium on Applications of Ferroelectrics (ISAF) · doi:10.1109/isaf.1994.522458 · Cited by 8
Cited by
Clinical translation of photoacoustic imaging
Park, J., Choi, S., Knieling, F., Clingman, B., Bohndiek, S., Wang, L. V., & Kim, C. (2024) · Nature Reviews Bioengineering · doi:10.1038/s44222-024-00240-y · Cited by 275
Birjis, Y., Swaminathan, S., Nazemi, H., Raj, G. C. A., Munirathinam, P., Abu-Libdeh, A., & Emadi, A. (2022) · Sensors · doi:10.3390/s22239151 · Cited by 84
Metadata
- Authors
- Jung, J., Lee, W., Kang, W., Shin, E., Ryu, J., & Choi, H.
- Venue
- Journal of Micromechanics and Microengineering
- Publisher
- IOP Publishing
- Published
- 2017-09-22
- Volume
- 27
- Issue
- 11
- Pages
- 113001
- ISSN
- 0960-1317 (ISSN-L)
- 1361-6439
- OpenAlex
- W2743764621
- Cited by
- 340
- References
- 69
- FWCI
- 10.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.