Optical frequency standards for time and length applications
Open accessThe DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Abstract
The last decade has witnessed tremendous progress in research on optical frequency metrology. Optical frequency standards using optical lattice and single-ion trap technologies have reached levels of stability and accuracy that surpass the performance of the best Cs fountain atomic clocks by orders of magnitude. Optical frequency standards are also used for various applications including length metrology. Optical frequency measurement and links using optical frequency combs and optical fibres play important roles in the development of optical frequency standards. This article introduces optical frequency standards recommended by the International Committee for Weights and Measures (CIPM) along with updates provided by recent research results. Frequency ratio measurements and remote frequency comparisons are addressed in relation to the work whose goal is to redefine the second. Optical frequency standard and optical frequency comb applications are also described.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jones, D. J., Diddams, S. A., Ranka, J. K., Stentz, A., Windeler, R. S., Hall, J. L., & Cundiff, S. T. (2000) · Science · doi:10.1126/science.288.5466.635 · Cited by 2,661 · cited 2×
“The invention of optical frequency combs [3, 4] has revolutionized the field of optical frequency measurement and further stimulated research on optical frequency standards.”
BackgroundMethodThe Effect of Collisions upon the Doppler Width of Spectral Lines
Dicke, R. H. (1953) · Physical Review · doi:10.1103/physrev.89.472 · Cited by 1,491
Frequency Ratio of Al+and Hg+Single-Ion Optical Clocks; Metrology at the 17th Decimal Place
Rosenband, T., Hume, D. B., Schmidt, P. O., Chou, C. W., Brusch, A., Lorini, L., Oskay, W. H., Drullinger, R. E., Fortier, T. M., Stalnaker, J. E., et al. (2008) · Science · doi:10.1126/science.1154622 · Cited by 1,450 · cited 11×
“The low uncertainty of the 27Al+ single-ion clock was validated at a level of 2 × 10−17 by using two Al+ clocks developed at NIST [22].”
BackgroundMethodInfluentialFrequency Comparison of Two High-Accuracy Al + Optical Clocks
Chou, C., Hume, D., Koelemeij, J., Wineland, D., & Rosenband, T. (2010) · Physical Review Letters · doi:10.1103/physrevlett.104.070802 · Cited by 903
Takamoto, M., Hong, F.-L., Higashi, R., & Katori, H. (2005) · Nature · doi:10.1038/nature03541 · Cited by 853
Self-citationChou, C. W., Hume, D. B., Rosenband, T., & Wineland, D. J. (2010) · Science · doi:10.1126/science.1192720 · Cited by 828
Systematic evaluation of an atomic clock at 2 × 10−18 total uncertainty
Nicholson, T. L., Campbell, S. L., Hutson, R. B., Marti, G. E., Bloom, B. J., McNally, R. L., Zhang, W., Barrett, M. D., Safronova, M. S., Strouse, G. F., et al. (2015) · Nature Communications · doi:10.1038/ncomms7896 · Cited by 780 · cited 2×
“At present, the 87Sr optical lattice clock [19, 20], the 171Yb+ single-ion clock (octupole transition) [21], and the 27Al+ single-ion clock [22] have been evaluated as having an uncertainty at the 10−18 level, which is about two orders of magnitude better than that of the current best Cs fountain clocks.”
BackgroundTime-domain mid-infrared frequency-comb spectrometer
Keilmann, F., Gohle, C., & Holzwarth, R. (2004) · Optics Letters · doi:10.1364/ol.29.001542 · Cited by 734 · cited 1×
“Dual comb spectr oscopy [166, 167] is performed to observe the spectra of atoms and molecules across a 140 THz wide spectrum from 1.”
MethodSingle-Ion Atomic Clock with 3 × 10 − 18 Systematic Uncertainty
Huntemann, N., Sanner, C., Lipphardt, B., Tamm, C., & Peik, E. (2016) · Physical Review Letters · doi:10.1103/physrevlett.116.063001 · Cited by 677 · cited 2×
“At present, the 87Sr optical lattice clock [19, 20], the 171Yb+ single-ion clock (octupole transition) [21], and the 27Al+ single-ion clock [22] have been evaluated as having an uncertainty at the 10−18 level, which is about two orders of magnitude better than that of the current best Cs fountain clocks.”
BackgroundSpectroscopy Using Quantum Logic
Schmidt, P. O., Rosenband, T., Langer, C., Itano, W. M., Bergquist, J. C., & Wineland, D. J. (2005) · Science · doi:10.1126/science.1114375 · Cited by 643
Cryogenic optical lattice clocks
Ushijima, I., Takamoto, M., Das, M., Ohkubo, T., & Katori, H. (2015) · Nature Photonics · doi:10.1038/nphoton.2015.5 · Cited by 627 · cited 4×
“At present, the 87Sr optical lattice clock [19, 20], the 171Yb+ single-ion clock (octupole transition) [21], and the 27Al+ single-ion clock [22] have been evaluated as having an uncertainty at the 10−18 level, which is about two orders of magnitude better than that of the current best Cs fountain clocks.”
BackgroundMethodInfluentialMa, L.-S., Jungner, P., Ye, J., & Hall, J. L. (1994) · Optics Letters · doi:10.1364/ol.19.001777 · Cited by 566 · cited 1×
“The ubiquitous fibre optic network enables us to transfer frequencies with an extremely low phase noise [145, 146].”
BackgroundA 920-Kilometer Optical Fiber Link for Frequency Metrology at the 19th Decimal Place
Predehl, K., Grosche, G., Raupach, S. M. F., Droste, S., Terra, O., Alnis, J., Legero, T., Hänsch, T. W., Udem, T., Holzwarth, R., et al. (2012) · Science · doi:10.1126/science.1218442 · Cited by 543
Hunting for topological dark matter with atomic clocks
Derevianko, A., & Pospelov, M. (2014) · Nature Physics · doi:10.1038/nphys3137 · Cited by 522
Godun, R. M., Nisbet-Jones, P. B. R., Jones, J. M., King, S. A., Johnson, L. A. M., Margolis, H. S., Szymaniec, K., Lea, S. N., Bongs, K., & Gill, P. (2014) · Physical Review Letters · doi:10.1103/physrevlett.113.210801 · Cited by 468
A clock network for geodesy and fundamental science
Lisdat, C., Grosche, G., Quintin, N., Shi, C., Raupach, S. M. F., Grebing, C., Nicolodi, D., Stefani, F., Al-Masoudi, A., Dörscher, S., et al. (2016) · Nature Communications · doi:10.1038/ncomms12443 · Cited by 460 · cited 4×
“An international comparison of two Sr optical lattice clocks at PTB and SYRTE was undertaken using a 1415 km long optical fibre network to confirm that the two clocks agreed at an uncertainty of 5 × 10−17 [39].”
BackgroundMethodInfluentialNuclear laser spectroscopy of the 3.5 eV transition in Th-229
Peik, E., & Tamm, C. (2003) · Europhysics Letters (EPL) · doi:10.1209/epl/i2003-00210-x · Cited by 435 · cited 1×
“Efforts are still being made to further reduce the systematic uncertainty of optical clocks to <1 × 10−18, either by improving the current optical clocks [154] or by starting new clock schemes using a nuclear clock transition in 229Th [155, 156] or highly charged ions [157, 158].”
BackgroundGravitational wave detection with optical lattice atomic clocks
Kolkowitz, S., Pikovski, I., Langellier, N., Lukin, M. D., Walsworth, R. L., & Ye, J. (2016) · Physical Review D · doi:10.1103/physrevd.94.124043 · Cited by 396
Improved Limit on a Temporal Variation ofmp/mefrom Comparisons ofYb+and Cs Atomic Clocks
Huntemann, N., Lipphardt, B., Tamm, C., Gerginov, V., Weyers, S., & Peik, E. (2014) · Physical Review Letters · doi:10.1103/physrevlett.113.210802 · Cited by 366
Optical Frequency Synthesis and Comparison with Uncertainty at the 10 -19 Level
Ma, L.-S., Bi, Z., Bartels, A., Robertsson, L., Zucco, M., Windeler, R. S., Wilpers, G., Oates, C., Hollberg, L., & Diddams, S. A. (2004) · Science · doi:10.1126/science.1095092 · Cited by 319
Direct detection of the 229Th nuclear clock transition
von der Wense, L., Seiferle, B., Laatiaoui, M., Neumayr, J. B., Maier, H.-J., Wirth, H.-F., Mokry, C., Runke, J., Eberhardt, K., Düllmann, C. E., et al. (2016) · Nature · doi:10.1038/nature17669 · Cited by 262 · cited 1×
“Efforts are still being made to further reduce the systematic uncertainty of optical clocks to <1 × 10−18, either by improving the current optical clocks [154] or by starting new clock schemes using a nuclear clock transition in 229Th [155, 156] or highly charged ions [157, 158].”
BackgroundExperimental realization of an optical second with strontium lattice clocks
Le Targat, R., Lorini, L., Le Coq, Y., Zawada, M., Guéna, J., Abgrall, M., Gurov, M., Rosenbusch, P., Rovera, D. G., Nagórny, B., et al. (2013) · Nature Communications · doi:10.1038/ncomms3109 · Cited by 250 · cited 1×
“The absolute frequency results include the measurements made by SYRTE in 2008 [55], JILA in 2008 [56] and UT-NMIJ in 2009 [57] that contributed to the CIPM recommendations in 2009, 2013 and 2015; the measurements of PTB in 2011 [58] and NICT in 2012 [59] that contributed to the CIPM recommendations in 2013 and 2015; t…”
MethodGeopotential measurements with synchronously linked optical lattice clocks
Takano, T., Takamoto, M., Ushijima, I., Ohmae, N., Akatsuka, T., Yamaguchi, A., Kuroishi, Y., Munekane, H., Miyahara, B., & Katori, H. (2016) · Nature Photonics · doi:10.1038/nphoton.2016.159 · Cited by 245
Frequency ratio of Yb and Sr clocks with 5 × 10−17 uncertainty at 150 seconds averaging time
Nemitz, N., Ohkubo, T., Takamoto, M., Ushijima, I., Das, M., Ohmae, N., & Katori, H. (2016) · Nature Photonics · doi:10.1038/nphoton.2016.20 · Cited by 221
A strontium lattice clock with 3 × 10−17inaccuracy and its frequency
Falke, S., Lemke, N., Grebing, C., Lipphardt, B., Weyers, S., Gerginov, V., Huntemann, N., Hagemann, C., Al-Masoudi, A., Häfner, S., et al. (2014) · New Journal of Physics · doi:10.1088/1367-2630/16/7/073023 · Cited by 182
Towards a redefinition of the second based on optical atomic clocks
Riehle, F. (2015) · Comptes Rendus. Physique · doi:10.1016/j.crhy.2015.03.012 · Cited by 174 · cited 3×
“Recent developments on optical frequency standards have encouraged time applications and accelerated work on the redefinition of the second [9, 10].”
BackgroundUltra-broadband dual-comb spectroscopy across 1.0–1.9 µm
Okubo, S., Iwakuni, K., Inaba, H., Hosaka, K., Onae, A., Sasada, H., & Hong, F.-L. (2015) · Applied Physics Express · doi:10.7567/apex.8.082402 · Cited by 173
Self-citationRealization of a timescale with an accurate optical lattice clock
Grebing, C., Al-Masoudi, A., Dörscher, S., Häfner, S., Gerginov, V., Weyers, S., Lipphardt, B., Riehle, F., Sterr, U., & Lisdat, C. (2016) · Optica · doi:10.1364/optica.3.000563 · Cited by 149 · cited 2×
“It has been demonstrated recently at PTB that an 87Sr optical lattice clock, with a time coverage of 46% over 25 d, is now able to maintain a local timescale with a time error of less than 200 ps, which is superior to one based on even the best Cs fountain clock [66].”
BackgroundMethodThe87Sr optical frequency standard at PTB
Falke, S., Schnatz, H., Winfred, J. S. R. V., Middelmann, T., Vogt, S., Weyers, S., Lipphardt, B., Grosche, G., Riehle, F., Sterr, U., et al. (2011) · Metrologia · doi:10.1088/0026-1394/48/5/022 · Cited by 129 · cited 1×
“The absolute frequency results include the measurements made by SYRTE in 2008 [55], JILA in 2008 [56] and UT-NMIJ in 2009 [57] that contributed to the CIPM recommendations in 2009, 2013 and 2015; the measurements of PTB in 2011 [58] and NICT in 2012 [59] that contributed to the CIPM recommendations in 2013 and 2015; t…”
MethodOptical to microwave clock frequency ratios with a nearly continuous strontium optical lattice clock
Lodewyck, J., Bilicki, S., Bookjans, E., Robyr, J.-L., Shi, C., Vallet, G., Le Targat, R., Nicolodi, D., Le Coq, Y., Guéna, J., et al. (2016) · Metrologia · doi:10.1088/0026-1394/53/4/1123 · Cited by 102 · cited 1×
“It has also been recently demonstrated at SYRTE that an 87Sr optical lattice clock can be reliably operated over time periods of several weeks, with a time coverage exceeding 80% [153].”
BackgroundComparing a mercury optical lattice clock with microwave and optical frequency standards
Tyumenev, R., Favier, M., Bilicki, S., Bookjans, E., Targat, R. L., Lodewyck, J., Nicolodi, D., Coq, Y. L., Abgrall, M., Guéna, J., et al. (2016) · New Journal of Physics · doi:10.1088/1367-2630/18/11/113002 · Cited by 85 · cited 4×
“The results include the measurements reported by SYRTE in 2012 [105, 106] and by RIKEN/UT in 2015 [103], that contributed to the CIPM recommendation in 2015; and one new result from SYRTE [104] that was published after the CIPM recommendation in 2015.”
BackgroundMethodResultInfluentialStrategies for reducing the light shift in atomic clocks
Katori, H., Ovsiannikov, V. D., Marmo, S. I., & Palchikov, V. G. (2015) · Physical Review A · doi:10.1103/physreva.91.052503 · Cited by 74 · cited 1×
“Efforts are still being made to further reduce the systematic uncertainty of optical clocks to <1 × 10−18, either by improving the current optical clocks [154] or by starting new clock schemes using a nuclear clock transition in 229Th [155, 156] or highly charged ions [157, 158].”
BackgroundCs-based optical frequency measurement using cross-linked optical and microwave oscillators
Tamm, C., Huntemann, N., Lipphardt, B., Gerginov, V., Nemitz, N., Kazda, M., Weyers, S., & Peik, E. (2014) · Physical Review A · doi:10.1103/physreva.89.023820 · Cited by 72 · cited 12×
“It has been confirmed that the two 87Sr optical lattice clocks at SYRTE and PTB agree with each other at an uncertainty of 5 × 10−17, limited by the instability and uncertainty of the strontium lattice clocks themselves.”
BackgroundMethodInfluentialIntermittent optical frequency measurements to reduce the dead time uncertainty of frequency link
Hachisu, H., & Ido, T. (2015) · Japanese Journal of Applied Physics · doi:10.7567/jjap.54.112401 · Cited by 48
Margolis, H. S., & Gill, P. (2015) · Metrologia · doi:10.1088/0026-1394/52/5/628 · Cited by 40 · cited 4×
“6 × 10−15, which was enlarged by a factor of 3 [41], by the CIPM, taking into account that the uncertainty obtained by least-squares analysis [43] is dominated by one result [92] with a much lower uncertainty than any of the others.”
BackgroundMethodResultInfluentialCoddington, I., Swann, W., & Newbury, N. (2008) · Physical Review Letters · doi:10.1103/physrevlett.101.049901 · Cited by 24
Cited by
The CIPM list of recommended frequency standard values: guidelines and procedures
Riehle, F., Gill, P., Arias, F., & Robertsson, L. (2018) · Metrologia · doi:10.1088/1681-7575/aaa302 · Cited by 281
Mehlstäubler, T. E., Grosche, G., Lisdat, C., Schmidt, P. O., & Denker, H. (2018) · Reports on Progress in Physics · doi:10.1088/1361-6633/aab409 · Cited by 263
Laser-Controlled Cold Ytterbium Atom Source for Transportable Optical Clocks
Yasuda, M., Tanabe, T., Kobayashi, T., Akamatsu, D., Sato, T., & Hatakeyama, A. (2017) · Journal of the Physical Society of Japan · doi:10.7566/jpsj.86.125001 · Cited by 13
Metadata
- Authors
- Hong, F.-L.
- Venue
- Measurement Science and Technology
- Publisher
- IOP Publishing
- Published
- 2016-12-01
- Volume
- 28
- Issue
- 1
- Pages
- 012002
- ISSN
- 0957-0233 (ISSN-L)
- 1361-6501
- OpenAlex
- W2559105651
- Cited by
- 82
- References
- 36
- FWCI
- 5.56
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.