High-density peripheral nerve cuffs restore natural sensation to individuals with lower-limb amputations
Open accessThe DOI matches its Crossref record; 56 of the 56 references it cites were found in a registry or an index.
Abstract
Objective . Sensory input in lower-limb amputees is critically important to maintaining balance, preventing falls, negotiating uneven terrain, responding to unexpected perturbations, and developing the confidence required for societal participation and public interactions in unfamiliar environments. Despite noteworthy advances in robotic prostheses for lower-limb amputees, such as microprocessor knees and powered ankles, natural somatosensory feedback from the lost limb has not yet been incorporated in current prosthetic technologies. Approach . In this work, we report eliciting somatic sensation with neural stimulation delivered by chronically-implanted, non-penetrating nerve cuff electrodes in two transtibial amputees. High-density, flexible, 16-contact nerve cuff electrodes were surgically implanted for the selective activation of sensory fascicles in the nerves of the posterior thigh above the knee. Electrical pulses at safe levels were delivered to the nerves by an external stimulator via percutaneous leads attached to the cuff electrodes. Main results . The neural stimulation was perceived by participants as sensation originating from the missing limb. We quantitatively and qualitatively ascertained the intensity, modality as well as the location and stability of the perceived sensations. Stimulation through individual contacts within the nerve cuffs evoked repeatable sensations of various modalities and at discrete locations projected to the missing toes, foot and ankle, as well as in the residual limb. In addition, we observed a high overlap in reported locations between distal versus proximal cuffs suggesting that the same sensory responses could be elicited from more proximal points on the nerve. Significance . Based on these findings, the high-density cuff technology is suitable for restoring natural sensation to lower-limb amputees and could be utilized in developing a neuroprosthesis with natural sensory feedback. The overlap in reported locations between proximal and distal cuffs indicates that our approach might be applicable to transfemoral amputees where distal muscles and branches of sciatic nerve are not available.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures










Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“The C-FINE was found successful in restoring sensation in individuals with a lower limb amputation [75].”
From Interfaces with the peripheral nervous system for the control of a neuroprosthetic limb: a review (2020) · cites this paper as [75]
The cited source says what the claim attributes to it.
In the citing paper
“Additionally, the effects of stimulation can be difficult to predict; both the location and quality of sensations evoked by stimulation of implanted electrode arrays can change significantly [14,15].”
From Fascicle specific targeting for selective peripheral nerve stimulation (2019) · cites this paper as [14]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrical stimulation of excitable tissue: design of efficacious and safe protocols
Merrill, D. R., Bikson, M., & Jefferys, J. G. R. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.10.020 · Cited by 2,078 · cited 1×
“7 is considered safe for pulse trains with inter-pulse frequency of 50 Hz and up to 7 h continuous stimulation [33, 34].”
BackgroundRestoring natural sensory feedback in real-time bidirectional hand prostheses
Raspopovic, S., Capogrosso, M., Petrini, F. M., Bonizzato, M., Rigosa, J., Di Pino, G., Carpaneto, J., Controzzi, M., Boretius, T., Fernandez, E., et al. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3006820 · Cited by 1,001
A neural interface provides long-term stable natural touch perception
Tan, D. W., Schiefer, M. A., Keith, M. W., Anderson, J. R., Tyler, J., & Tyler, D. J. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3008669 · Cited by 751
Self-citationCharge density and charge per phase as cofactors in neural injury induced by electrical stimulation
McCreery, D. B., Agnew, W. F., Yuen, T. G. H., & Bullara, L. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.102812 · Cited by 708 · cited 1×
“7 is considered safe for pulse trains with inter-pulse frequency of 50 Hz and up to 7 h continuous stimulation [33, 34].”
BackgroundIntracortical microstimulation of human somatosensory cortex
Flesher, S. N., Collinger, J. L., Foldes, S. T., Weiss, J. M., Downey, J. E., Tyler-Kabara, E. C., Bensmaia, S. J., Schwartz, A. B., Boninger, M. L., & Gaunt, R. A. (2016) · Science Translational Medicine · doi:10.1126/scitranslmed.aaf8083 · Cited by 704 · cited 1×
“Our results from intensity discrimination experiments corroborate previously reported observations in sensory restoration in the upper limb [35, 52].”
ResultThe prevalence and risk factors of falling and fear of falling among lower extremity amputees
Miller, W. C., Speechley, M., & Deathe, B. (2001) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2001.24295 · Cited by 642 · cited 1×
“from sensory restoration as their fall risk [40, 41], reliance on”
BackgroundA model of safe levels for electrical stimulation
Shannon, R. V. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.126616 · Cited by 526 · cited 1×
“where QD is the charge density per phase (μC cm−2) and Q is charge per phase (μC) [32].”
BackgroundPowered Ankle--Foot Prosthesis Improves Walking Metabolic Economy
Au, S. K., Weber, J., & Herr, H. (2009) · IEEE Transactions on Robotics · doi:10.1109/tro.2008.2008747 · Cited by 487 · cited 1×
“Design iterations of prostheses have focused on improving confidence in walking [3], reducing reliance on the intact limb [4, 5], and lowering metabolic energy expenditure during level-ground walking [6, 7] mainly by taking advantage of integrated robotic systems [8] and employing versatile control strategies [9].”
BackgroundFoot sole and ankle muscle inputs contribute jointly to human erect posture regulation
Kavounoudias, A., Roll, R., & Roll, J. (2001) · The Journal of Physiology · doi:10.1111/j.1469-7793.2001.0869e.x · Cited by 479 · cited 1×
“In neurologically intact individuals, foot sole tactile afferents contribute to body posture awareness [11], erect stance maintenance [12], and sensing the direction of ankle movement [13].”
BackgroundMore than skin deep: Body representation beyond primary somatosensory cortex
Longo, M. R., Azañón, E., & Haggard, P. (2010) · Neuropsychologia · doi:10.1016/j.neuropsychologia.2009.08.022 · Cited by 479 · cited 1×
“These changes in the mental image of the limb align with previous work suggesting that conscious body image arises from several sources of input, including tactile afferents (for review, see [51]).”
BackgroundDistribution and behaviour of glabrous cutaneous receptors in the human foot sole
Kennedy, P. M., & Inglis, J. T. (2002) · The Journal of Physiology · doi:10.1113/jphysiol.2001.013087 · Cited by 438 · cited 2×
“Compared to the glabrous skin of the hand, the skin of the foot sole has a lower proportion of slowly adapting (SA) receptors, which respond to continuous stimuli like those used in the JND test [53].”
BackgroundEnergy expenditure and biomechanical characteristics of lower limb amputee gait:
Schmalz, T., Blumentritt, S., & Jarasch, R. (2002) · Gait & Posture · doi:10.1016/s0966-6362(02)00008-5 · Cited by 428 · cited 1×
“Design iterations of prostheses have focused on improving confidence in walking [3], reducing reliance on the intact limb [4, 5], and lowering metabolic energy expenditure during level-ground walking [6, 7] mainly by taking advantage of integrated robotic systems [8] and employing versatile control strategies [9].”
BackgroundCutaneous Receptors Contribute to Kinesthesia at the Index Finger, Elbow, and Knee
Collins, D. F., Refshauge, K. M., Todd, G., & Gandevia, S. C. (2005) · Journal of Neurophysiology · doi:10.1152/jn.00191.2005 · Cited by 416 · cited 1×
“Furthermore, prior work indicates information from cutaneous receptors contribute to the perception of joint movement or joint position [48].”
BackgroundBionic ankle–foot prosthesis normalizes walking gait for persons with leg amputation
Herr, H. M., & Grabowski, A. M. (2012) · Proceedings of the Royal Society B: Biological Sciences · doi:10.1098/rspb.2011.1194 · Cited by 391
Shull, P. B., Jirattigalachote, W., Hunt, M. A., Cutkosky, M. R., & Delp, S. L. (2014) · Gait & Posture · doi:10.1016/j.gaitpost.2014.03.189 · Cited by 388
Strength-duration properties of human peripheral nerve
Mogyoros, I., Kiernan, M. C., & Burke, D. (1996) · Brain · doi:10.1093/brain/119.2.439 · Cited by 358 · cited 1×
“We measured strength-duration (SD) curves to probe for any peripheral nerve degeneration [39] due to the implanted C-FINEs.”
MethodDavis, T. S., Wark, H. A. C., Hutchinson, D. T., Warren, D. J., O’Neill, K., Scheinblum, T., Clark, G. A., Normann, R. A., & Greger, B. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/3/036001 · Cited by 314
The effect of changes in foot sensation on plantar pressure and muscle activity
Nurse, M. A., & Nigg, B. M. (2001) · Clinical Biomechanics · doi:10.1016/s0268-0033(01)00090-0 · Cited by 305
A Clinical Comparison of Variable-Damping and Mechanically Passive Prosthetic Knee Devices
Johansson, J. L., Sherrill, D. M., Riley, P. O., Bonato, P., & Herr, H. (2005) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/01.phm.0000174665.74933.0b · Cited by 302 · cited 1×
“Design iterations of prostheses have focused on improving confidence in walking [3], reducing reliance on the intact limb [4, 5], and lowering metabolic energy expenditure during level-ground walking [6, 7] mainly by taking advantage of integrated robotic systems [8] and employing versatile control strategies [9].”
BackgroundProsthetic gait of unilateral transfemoral amputees: A kinematic study
Jaegers, S. M. H. J., Arendzen, J. H., & de Jongh, H. J. (1995) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(95)80528-1 · Cited by 293 · cited 1×
“It has been suggested that lack of sensory feedback in amputees contributes to asymmetric gait [14], poor balance [15], reliance on vision [16], slower cadence [17], and increased falling rates [18].”
BackgroundThe neural basis of perceived intensity in natural and artificial touch
Graczyk, E. L., Schiefer, M. A., Saal, H. P., Delhaye, B. P., Bensmaia, S. J., & Tyler, D. J. (2016) · Science Translational Medicine · doi:10.1126/scitranslmed.aaf5187 · Cited by 258 · cited 4×
“Our results from intensity discrimination experiments corroborate previously reported observations in sensory restoration in the upper limb [35, 52].”
BackgroundMethodResultSelf-citationEnabling factors related to prosthetic use by people with transtibial and transfemoral amputation
Gauthier-Gagnon, C., Grisé, M.-C., & Potvin, D. (1999) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(99)90177-6 · Cited by 242 · cited 2×
“vision [16], and concentration on gait [41] is higher compared”
BackgroundCutaneous afferents from human plantar sole contribute to body posture awareness
Roll, R., Kavounoudias, A., & Roll, J.-P. (2002) · NeuroReport · doi:10.1097/00001756-200210280-00025 · Cited by 237 · cited 1×
“In neurologically intact individuals, foot sole tactile afferents contribute to body posture awareness [11], erect stance maintenance [12], and sensing the direction of ankle movement [13].”
BackgroundCardiovascular Reflex Control by Afferent Fibers from Skeletal Muscle Receptors
Mitchell, J. H., & Schmidt, R. F. (1983) · Comprehensive Physiology · doi:10.1002/cphy.cp020317 · Cited by 224 · cited 1×
“In fact, Mitchel and Schmidt report that afferent fibers from the lateral gastrocnemius and soleus muscles are 30%, 15%, and 32% Ia, Ib, and II fibers, respectively [47], suggesting marked contribution of group II fibers to proprioception in these skeletal muscles.”
BackgroundElectrocutaneous Stimulation for Sensory Communication in Rehabilitation Engineering
Szeto, A. Y. J., & Saunders, F. A. (1982) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1982.324948 · Cited by 223
Peripheral Neural Mechanisms in Proprioception
Grigg, P. (1994) · Journal of Sport Rehabilitation · doi:10.1123/jsr.3.1.2 · Cited by 223 · cited 1×
“For example, Ruffini corpuscles, a group of subcutaneous mechanoreceptors, respond to skin stretch and play an important role in sensation related to joint movement [49].”
BackgroundJohansson, R. S., & Vallbo, Å. B. (1980) · Brain Research · doi:10.1016/0006-8993(80)90804-5 · Cited by 198
Balance Confidence Among People With Lower-Limb Amputations
Miller, W. C., Speechley, M., & Deathe, A. B. (2002) · Physical Therapy · doi:10.1093/ptj/82.9.856 · Cited by 183
Tan, D. W., Schiefer, M. A., Keith, M. W., Anderson, J. R., & Tyler, D. J. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/2/026002 · Cited by 175 · cited 1×
“Similar technology has been implanted for over four years in people with upper limb amputation without failure in response [26, 56].”
MethodSelf-citationFoot and Ankle Sensory Neuropathy, Proprioception, and Postural Stability
van Deursen, R. W. M., & Simoneau, G. G. (1999) · Journal of Orthopaedic & Sports Physical Therapy · doi:10.2519/jospt.1999.29.12.718 · Cited by 173 · cited 1×
“Regardless of the neural pathway, our approach can elicit tactile and proprioceptive sensations, both of which provide important contributions to postural control [44, 45].”
BackgroundIntuitive Control of a Powered Prosthetic Leg During Ambulation: A Randomized Clinical Trial
Hargrove, L. J., Young, A. J., Simon, A. M., Fey, N. P., Lipschutz, R. D., Finucane, S. B., Halsne, E. G., Ingraham, K. A., & Kuiken, T. A. (2015) · JAMA · doi:10.1001/jama.2015.4527 · Cited by 153
Postural sway in amputees and normal subjects.
Fernie, G. R., & Holliday, P. J. (1978) · Journal of Bone and Joint Surgery · doi:10.2106/00004623-197860070-00003 · Cited by 150
Falls in Patients with Lower Limb Amputations: Prevalence and Contributing Factors
Kulkarni, J., Wright, S., Toole, C. M., Morris, J., & Hirons, R. (1996) · Physiotherapy · doi:10.1016/s0031-9406(05)66968-4 · Cited by 146 · cited 1×
“It has been suggested that lack of sensory feedback in amputees contributes to asymmetric gait [14], poor balance [15], reliance on vision [16], slower cadence [17], and increased falling rates [18].”
BackgroundPowers, C. M., Torburn, L., Perry, J., & Ayyappa, E. (1994) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/0003-9993(94)90146-5 · Cited by 145 · cited 1×
“Design iterations of prostheses have focused on improving confidence in walking [3], reducing reliance on the intact limb [4, 5], and lowering metabolic energy expenditure during level-ground walking [6, 7] mainly by taking advantage of integrated robotic systems [8] and employing versatile control strategies [9].”
BackgroundPolasek, K. H., Hoyen, H. A., Keith, M. W., Kirsch, R. F., & Tyler, D. J. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2032603 · Cited by 142
Self-citationDingwell, J. B., Davis, B. L., & Frazder, D. M. (1996) · Prosthetics & Orthotics International · doi:10.3109/03093649609164426 · Cited by 141 · cited 2×
“Sensory substitution, such as audio and visual feedback, can positively impact gait symmetry in transtibial amputees [22, 23].”
BackgroundAimonetti, J., Hospod, V., Roll, J., & Ribot‐Ciscar, E. (2007) · The Journal of Physiology · doi:10.1113/jphysiol.2006.123075 · Cited by 140 · cited 1×
“In neurologically intact individuals, foot sole tactile afferents contribute to body posture awareness [11], erect stance maintenance [12], and sensing the direction of ankle movement [13].”
BackgroundTactile perception, cortical representation and the bodily self
Haggard, P., Taylor-Clarke, M., & Kennett, S. (2003) · Current Biology · doi:10.1016/s0960-9822(03)00115-5 · Cited by 138 · cited 2×
“In addition, receptive field areas for mechanoreceptors in the foot are three times larger than those found in the hand [53, 54], leading to poorer location discrimination [55].”
BackgroundA Haptic Feedback System for Lower-Limb Prostheses
Fan, R. E., Culjat, M. O., King, C.-H., Franco, M. L., Boryk, R., Bisley, J. W., Dutson, E., & Grundfest, W. S. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.920075 · Cited by 138 · cited 3×
“Fan et al [21] demonstrated that pneumatic balloon actuators placed on the upper leg in able-bodied individuals could provide accurate perception of directional forces on the foot during stance.”
BackgroundSensory pathways and their modulation in the control of locomotion
Büschges, A., & Manira, A. E. (1998) · Current Opinion in Neurobiology · doi:10.1016/s0959-4388(98)80115-3 · Cited by 125 · cited 1×
“However, human locomotion is a dynamic integration of motor and sensory systems where sensory signals generated in the lower limbs influence motor output [10].”
BackgroundSensory adaptation to electrical stimulation of the somatosensory nerves
Graczyk, E. L., Delhaye, B. P., Schiefer, M. A., Bensmaia, S. J., & Tyler, D. J. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aab790 · Cited by 124 · cited 1×
“Although we did not probe effects of adaptation in this work, prolonged exposure to stimuli could lead to adaptation as reported in various approaches including nerve stimulation [36], electro-cutaneous stimulation [37], and vibrotactile sensory substitution [38].”
BackgroundSelf-citationMiller, E. W., Quinn, M. E., & Seddon, P. G. (2002) · Physical Therapy · doi:10.1093/ptj/82.1.53 · Cited by 117
Crea, S., Edin, B. B., Knaepen, K., Meeusen, R., & Vitiello, N. (2017) · Physical Therapy · doi:10.2522/ptj.20150441 · Cited by 110
Crea, S., Cipriani, C., Donati, M., Carrozza, M. C., & Vitiello, N. (2015) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2365548 · Cited by 90 · cited 3×
“Similarly, vibrating elements on the amputees’ thighs can provide time-discrete feedback for control of gait [19].”
BackgroundFisher, L. E., Tyler, D. J., Anderson, J. S., & Triolo, R. J. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/4/046010 · Cited by 89 · cited 1×
“For a subgroup of contacts selected randomly, SD curves were calculated by determining the thresholds at multiple PA levels followed by fitting the data to Wiess’s equation [30],”
MethodSelf-citationYang, L., Dyer, P. S., Carson, R. J., Webster, J. B., Foreman, K. B., & Bamberg, S. J. M. (2012) · Gait & Posture · doi:10.1016/j.gaitpost.2012.04.004 · Cited by 79 · cited 2×
“Sensory substitution, such as audio and visual feedback, can positively impact gait symmetry in transtibial amputees [22, 23].”
BackgroundPerceived Intensity of Vibrotactile Stimuli: The Role of Mechanoreceptive Channels
Hollins, M., & Roy, E. A. (1996) · Somatosensory & Motor Research · doi:10.3109/08990229609052583 · Cited by 63 · cited 1×
“Although we did not probe effects of adaptation in this work, prolonged exposure to stimuli could lead to adaptation as reported in various approaches including nerve stimulation [36], electro-cutaneous stimulation [37], and vibrotactile sensory substitution [38].”
BackgroundAfferent Sensory Feedback for Lower Extremity Prosthesis
CLIPPINGER, F. W., SEABER, A. V., MCELHANEY, J. H., HARRELSON, J. M., & MAXWELL, G. M. (1982) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198209000-00031 · Cited by 54
The design of and chronic tissue response to a composite nerve electrode with patterned stiffness
Freeberg, M. J., Stone, M. A., Triolo, R. J., & Tyler, D. J. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa6632 · Cited by 54 · cited 3×
“These devices do not breach the epineurium, can be fabricated to conform to the shape of the target nerves while exerting minimal pressure and maintaining blood flow, and preserve structural, physiological and clinical indications of nerve health during chronic applications [29].”
BackgroundMethodSelf-citationClites, T. R., Carty, M. J., Srinivasan, S., Zorzos, A. N., & Herr, H. M. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa614b · Cited by 53 · cited 1×
“Regardless of the neural pathway, our approach can elicit tactile and proprioceptive sensations, both of which provide important contributions to postural control [44, 45].”
BackgroundSense of Feel for Lower-Limb Amputees: A Phase-One Study
Sabolich, J. A., & Ortega, G. M. (1994) · JPO Journal of Prosthetics and Orthotics · doi:10.1097/00008526-199400620-00003 · Cited by 51 · cited 3×
“It has been suggested that lack of sensory feedback in amputees contributes to asymmetric gait [14], poor balance [15], reliance on vision [16], slower cadence [17], and increased falling rates [18].”
BackgroundZidarov, D., SWAINE, B. R., & Gauthier-Gagnon, C. (2009) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2009.06.011 · Cited by 50
Pagel, A., Arieta, A. H., Riener, R., & Vallery, H. (2015) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-015-1432-2 · Cited by 45
Beyond function: Using assistive technologies following lower limb loss
Dunne, S., Coffey, L., Gallagher, P., Desmond, D. M., & Ryall, N. H. (2015) · Journal of Rehabilitation Medicine · doi:10.2340/16501977-1962 · Cited by 30 · cited 1×
“Individuals with lower-limb amputations use assistive technologies, such as prostheses, to overcome mobility limitations [1] and improve their functional capabilities in activities of daily living [2].”
BackgroundCross-sectional Microscopic Anatomy of the Sciatic Nerve and its Dissected Branches
Reina, M. Á., Sala‐Blanch, X., & Fernández, P. (2014) · Springer eBooks · doi:10.1007/978-3-319-09522-6_10 · Cited by 5
Wolf, E. J., & Pruziner, A. L. (2014) · JPO Journal of Prosthetics and Orthotics · doi:10.1097/jpo.0000000000000029 · Cited by 5
Research works printed but not linked: 1
- 46. Lundy-Ekman L 2013 Neuroscience-E-Book: Fundamentals for Rehabilitation (Amsterdam: Elsevier)
Cited by
George, J. A., Kluger, D. T., Davis, T. S., Wendelken, S. M., Okorokova, E. V., He, Q., Duncan, C. C., Hutchinson, D. T., Thumser, Z. C., Beckler, D. T., et al. (2019) · Science Robotics · doi:10.1126/scirobotics.aax2352 · Cited by 388
Self-citationSensory feedback for limb prostheses in amputees
Raspopovic, S., Valle, G., & Petrini, F. M. (2021) · Nature Materials · doi:10.1038/s41563-021-00966-9 · Cited by 308
Sensory feedback restoration in leg amputees improves walking speed, metabolic cost and phantom pain
Petrini, F. M., Bumbasirevic, M., Valle, G., Ilic, V., Mijović, P., Čvančara, P., Barberi, F., Katic, N., Bortolotti, D., Andreu, D., et al. (2019) · Nature Medicine · doi:10.1038/s41591-019-0567-3 · Cited by 269
Enhancing functional abilities and cognitive integration of the lower limb prosthesis
Petrini, F. M., Valle, G., Bumbasirevic, M., Barberi, F., Bortolotti, D., Cvancara, P., Hiairrassary, A., Mijovic, P., Sverrisson, A. Ö., Pedrocchi, A., et al. (2019) · Science Translational Medicine · doi:10.1126/scitranslmed.aav8939 · Cited by 265
“The map of elicited sensations in transtibial amputees implanted with flat interface nerve electrodes has been reported (16), however, without prosthesis connection or functional assessment.”
BackgroundFleming, A., Stafford, N., Huang, S., Hu, X., Ferris, D. P., & Huang, H. (. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac1176 · Cited by 216
Metadata
- Authors
- Charkhkar, H., Shell, C. E., Marasco, P. D., Pinault, G. J., Tyler, D. J., & Triolo, R. J.
- Affiliations
- Louis Stokes Cleveland VA Medical Center (US)
- Cleveland Clinic (US)
- Corresponding author
- Charkhkar, Hamid
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2018-07-02
- Volume
- 15
- Issue
- 5
- Pages
- 056002
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2806169161
- Semantic Scholar
- 719c9f12682c4cd9064d7ea2d45e2af7cfbb4daa
- Cited by
- 131
- References
- 56
- Citations by year
- 2026: 10 · 2025: 22 · 2024: 12 · 2023: 22 · 2022: 15 · 2021: 21 · 2020: 8 · 2019: 20 · 2018: 1
- FWCI
- 5.71
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/3.0/ (vor)
- iopscience.iop.org/info/page/text-and-data-mining (tdm)
- Locations
- Journal of Neural Engineering (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Funders
- Defense Advanced Research Projects Agency (N66001-15-C-4038)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Health Sciences › Medicine › Anesthesiology and Pain Medicine › Pain Management and Treatment
- Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
- Keywords
- lower limb amputation, transtibial amputees, sensory feedback, neurostimulation, somatosensory feedback, neural prostheses, sciatic nerve, percutaneous leads, sensory perception
- MeSH terms
- Aged, Amputation, Traumatic, Amputees, Artificial Limbs, Electric Stimulation, Electrodes, Humans, Male, Middle Aged, Peripheral Nerves, Phantom Limb, Prosthesis Design, Sensation Disorders, Sensory Thresholds, Lower Extremity, Neural Prostheses
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.