Naturalistic spatiotemporal modulation of epiretinal stimulation increases the response persistence of retinal ganglion cell
Open accessThe DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
Objective. Retinal stimulation in blind patients evokes the sensation of discrete points of light called phosphenes, which allows them to perform visually guided tasks, such as orientation, navigation, object recognition, object manipulation and reading. However, the clinical benefit of artificial vision in profoundly blind patients is still tenuous, as several engineering and biophysical obstacles keep it far away from natural perception. The relative preservation of the inner retinal neurons in hereditary degenerative retinal diseases, such as retinitis pigmentosa, supports artificial vision through the network-mediated stimulation of retinal ganglion cells (RGCs). However, the response of RGCs to repeated electrical stimulation rapidly declines, primarily because of the intrinsic desensitisation of their excitatory network. In patients, upon repetitive stimulation, phosphenes fade out in less than half of a second, which drastically limits the understanding of the percept. Approach. A more naturalistic stimulation strategy, based on spatiotemporal modulation of electric pulses, could overcome the desensitisation of RGCs. To investigate this hypothesis, we performed network-mediated epiretinal stimulations paired to electrophysiological recordings in retinas explanted from both male and female retinal degeneration 10 mice. Main results. The results showed that the spatial and temporal modulation of the network-mediated epiretinal stimulation prolonged the persistence of the RGC’s response from 400 ms up to 4.2 s. Significance. A time-varied, non-stationary and interrupted stimulation of the retinal network, mimicking involuntary microsaccades, might reduce the fading of the visual percept and improve the clinical efficacy of retinal implants.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hartong, D. T., Berson, E. L., & Dryja, T. P. (2006) · The Lancet · doi:10.1016/s0140-6736(06)69740-7 · Cited by 2,924
Unsupervised spike detection and sorting with wavelets and superparamagnetic clustering
Quiroga, R. Q., Nadasdy, Z., & Ben-Shaul, Y. (2004) · Neural Computation · doi:10.1162/089976604774201631 · Cited by 2,119
The functional diversity of retinal ganglion cells in the mouse
Baden, T., Berens, P., Franke, K., Román Rosón, M., Bethge, M., & Euler, T. (2016) · Nature · doi:10.1038/nature16468 · Cited by 999 · cited 1×
“In our study, the pixels are separated by 120 μm, and most RGC in the mouse retina have dendritic fields exceeding this value [73]: at least two pixels can activate an RGC.”
BackgroundHamel, C. (2006) · Orphanet Journal of Rare Diseases · doi:10.1186/1750-1172-1-40 · Cited by 962
Artificial vision with wirelessly powered subretinal electronic implant alpha-IMS
Stingl, K., Bartz-Schmidt, K. U., Besch, D., Braun, A., Bruckmann, A., Gekeler, F., Greppmaier, U., Hipp, S., Hörtdörfer, G., Kernstock, C., et al. (2013) · Proceedings of the Royal Society B: Biological Sciences · doi:10.1098/rspb.2013.0077 · Cited by 473 · cited 1×
“Retinitis pigmentosa patients implanted with the alpha IMS/AMS devices reported phosphene fading with high variability in the fading rate amongst patients [23, 24], while agerelatedmacular degeneration patients implantedwith the PRIMA device did not [63].”
BackgroundSubretinal visual implant alpha IMS - clinical trial interim report
Stingl, K., Bartz-Schmidt, K. U., Besch, D., Chee, C. K., Cottriall, C. L., Gekeler, F., Groppe, M., Jackson, T. L., MacLaren, R. E., Koitschev, A., et al. (2015) · Vision Research · doi:10.1016/j.visres.2015.03.001 · Cited by 387
da Cruz, L., Coley, B. F., Dorn, J., Merlini, F., Filley, E., Christopher, P., Chen, F. K., Wuyyuru, V., Sahel, J., Stanga, P., et al. (2013) · British Journal of Ophthalmology · doi:10.1136/bjophthalmol-2012-301525 · Cited by 359 · cited 1×
“The artificial vision provided by retinal implants allows profoundly blind patients to perform visual guided tasks, such as orientation, navigation, object recognition, object manipulation and reading [44, 45].”
BackgroundPhotovoltaic Restoration of Central Vision in Atrophic Age-Related Macular Degeneration
Palanker, D., Le Mer, Y., Mohand-Said, S., Muqit, M., & Sahel, J. A. (2020) · Ophthalmology · doi:10.1016/j.ophtha.2020.02.024 · Cited by 227
Edwards, T. L., Cottriall, C. L., Xue, K., Simunovic, M. P., Ramsden, J. D., Zrenner, E., & MacLaren, R. E. (2018) · Ophthalmology · doi:10.1016/j.ophtha.2017.09.019 · Cited by 193 · cited 1×
“The artificial vision provided by retinal implants allows profoundly blind patients to perform visual guided tasks, such as orientation, navigation, object recognition, object manipulation and reading [44, 45].”
BackgroundThe functional performance of the Argus II retinal prosthesis
Stronks, H. C., & Dagnelie, G. (2014) · Expert Review of Medical Devices · doi:10.1586/17434440.2014.862494 · Cited by 189 · cited 3×
“Indeed they often describe a fast fading phase (hundreds of milliseconds) followed by a slow fading phase (tens of seconds) [22, 26].”
BackgroundWeiland, J. D., & Humayun, M. S. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2314733 · Cited by 186
Design and validation of a foldable and photovoltaic wide-field epiretinal prosthesis
Ferlauto, L., Airaghi Leccardi, M. J. I., Chenais, N. A. L., Gilliéron, S. C. A., Vagni, P., Bevilacqua, M., Wolfensberger, T. J., Sivula, K., & Ghezzi, D. (2018) · Nature Communications · doi:10.1038/s41467-018-03386-7 · Cited by 183
Self-citationImproving the spatial resolution of epiretinal implants by increasing stimulus pulse duration
Weitz, A. C., Nanduri, D., Behrend, M. R., Gonzalez-Calle, A., Greenberg, R. J., Humayun, M. S., Chow, R. H., & Weiland, J. D. (2015) · Science Translational Medicine · doi:10.1126/scitranslmed.aac4877 · Cited by 154
Boinagrov, D., Pangratz-Fuehrer, S., Goetz, G., & Palanker, D. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/2/026008 · Cited by 146 · cited 2×
“The relative preservation of the inner retinal neurons in retinitis pigmentosa [3–5] supports artificial vision through the network-mediated stimulation of retinal ganglion cells (RGCs) either from the subretinal or the epiretinal side [6, 7].”
BackgroundKagan, I., Gur, M., & Snodderly, D. M. (2008) · Journal of Vision · doi:10.1167/8.14.19 · Cited by 136 · cited 1×
“However, in sighted humans, a variety of ocular micromovements refresh the image and limit retinal adaptation: drifts andmicrosaccades cause frequent changes in the retinal image allowing to counteract the fading of the neural response [30, 31].”
BackgroundElectronic retinal implants and artificial vision: journey and present
Mills, J. O., Jalil, A., & Stanga, P. E. (2017) · Eye · doi:10.1038/eye.2017.65 · Cited by 133 · cited 1×
“The stimulation rate was set to 5 Hz as it was shown to be a comfortable stimulation rate for most patients [26, 41], while it is low enough to allow the temporal modulation of the electric pulses.”
BackgroundRetinal ganglion cell synchronization by fixational eye movements improves feature estimation
Greschner, M., Bongard, M., Rujan, P., & Ammermüller, J. (2002) · Nature Neuroscience · doi:10.1038/nn821 · Cited by 118
Temporal properties of visual perception on electrical stimulation of the retina
Pérez Fornos, A., Sommerhalder, J., da Cruz, L., Sahel, J. A., Mohand-Said, S., Hafezi, F., & Pelizzone, M. (2012) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.11-9344 · Cited by 113
Chenais, N. A. L., Airaghi Leccardi, M. J. I., & Ghezzi, D. (2021) · Communications Materials · doi:10.1038/s43246-021-00133-2 · Cited by 110
Self-citationFunctional compensation precedes recovery of tissue mass following acute liver injury
Walesky, C. M., Kolb, K. E., Winston, C. L., Henderson, J., Kruft, B., Fleming, I., Ko, S., Monga, S. P., Mueller, F., Apte, U., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-19558-3 · Cited by 103
Erickson-Davis, C., & Korzybska, H. (2021) · PLoS ONE · doi:10.1371/journal.pone.0229189 · Cited by 83
Finn, A., Grewal, D., & Vajzovic, L. (2018) · Clinical ophthalmology · doi:10.2147/opth.s137525 · Cited by 71
Activation of ganglion cells and axon bundles using epiretinal electrical stimulation
Grosberg, L. E., Ganesan, K., Goetz, G. A., Madugula, S. S., Bhaskhar, N., Fan, V., Li, P., Hottowy, P., Dabrowski, W., Sher, A., et al. (2017) · Journal of Neurophysiology · doi:10.1152/jn.00750.2016 · Cited by 70
Paraskevoudi, N., & Pezaris, J. S. (2019) · Frontiers in Systems Neuroscience · doi:10.3389/fnsys.2018.00073 · Cited by 39
Thorn, J. T., Migliorini, E., & Ghezzi, D. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/abb5bc · Cited by 34
Self-citationChenais, N. A. L., Leccardi, M. J. I. A., & Ghezzi, D. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab3913 · Cited by 24 · cited 4×
“Each pixel of the POLYRETINA prosthesis delivers, upon pulsed illumination, a capacitive stimulation characterised by a monophasic cathodic non-rectangular voltage pulse [13].”
BackgroundMethodInfluential
Cited by
Chenais, N. A. L., Airaghi Leccardi, M. J. I., & Ghezzi, D. (2021) · Communications Materials · doi:10.1038/s43246-021-00133-2 · Cited by 110
Self-citationPOLYRETINA restores light responses in vivo in blind Göttingen minipigs
Vagni, P., Airaghi Leccardi, M. J. I., Vila, C.-H., Zollinger, E. G., Sherafatipour, G., Wolfensberger, T. J., & Ghezzi, D. (2022) · Nature Communications · doi:10.1038/s41467-022-31180-z · Cited by 62
“33 Before surgery After surgery After surgery (1-100) After surgery (101-200) e b Light-adapted 300”
BackgroundSelf-citationAdvances in visual prostheses: engineering and biological challenges
Borda, E., & Ghezzi, D. (2022) · Progress in Biomedical Engineering · doi:10.1088/2516-1091/ac812c · Cited by 44
Self-citationThorn, J. T., Chenais, N. A. L., Hinrichs, S., Chatelain, M., & Ghezzi, D. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac5a5c · Cited by 11
Self-citationGaillet, V., Borda, E., Zollinger, E. G., & Ghezzi, D. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/abf523 · Cited by 10
“Retinal network-mediated stimulation in retinitis pigmentosa patients is also subjected to rapid phosphene’s fading due to static adaptation and bipolar cells’ desensitisation [30, 31]: a phenomenon requiring cognitively exhausting large head and body movements to counteract it.”
BackgroundSelf-citation
Metadata
- Authors
- Chenais, N. A. L., Airaghi Leccardi, M. J. I., & Ghezzi, D.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2021-02-01
- Volume
- 18
- Issue
- 1
- Pages
- 016016
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W3106865913
- Cited by
- 25
- References
- 26
- FWCI
- 1.89
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.