Visual cortex responses to suprachoroidal electrical stimulation of the retina: effects of electrode return configuration
The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
A clinically effective retinal prosthesis must evoke localized phosphenes in a retinotopic manner in response to stimulation of each of the retinal electrodes, evoke brightness cues over a wide dynamic range and function within safe stimulus limits. The effects of varying return configuration for retinal stimulation are currently unknown. To investigate this, we implanted a flexible, 7 × 12 electrode array into the suprachoroidal space of normally-sighted, anesthetized cats. Multi-unit activity in the primary visual cortex was recorded in response to electrical stimulation using various return configurations: monopolar vitreous (MPV), common ground (CG), hexagonal (HX), monopolar remote (MPR) and bipolar (BP_N). MPV stimulation was found to be the most charge efficient and was most likely to induce cortical activity within safe charge limits. HX and CG stimulation were found to exhibit greater retinal selectivity compared to the MPV return at the expense of lower cortical yield and higher P50 charge levels, while cortical selectivity was unaffected by choice of return. Responses using MPR and widely spaced BP_N configurations were similar to those using the MPV return. These results suggest that choice of return configuration for a retinal prosthesis will be balanced between resolution and stimulation within safe charge limits.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Receptive fields of single neurones in the cat's striate cortex
Hubel, D. H., & Wiesel, T. N. (1959) · The Journal of Physiology · doi:10.1113/jphysiol.1959.sp006308 · Cited by 4,653
Hartong, D. T., Berson, E. L., & Dryja, T. P. (2006) · The Lancet · doi:10.1016/s0140-6736(06)69740-7 · Cited by 2,924
Visual perception in a blind subject with a chronic microelectronic retinal prosthesis
Humayun, M. S., Weiland, J. D., Fujii, G. Y., Greenberg, R., Williamson, R., Little, J., Mech, B., Cimmarusti, V., Van Boemel, G., Dagnelie, G., et al. (2003) · Vision Research · doi:10.1016/s0042-6989(03)00457-7 · Cited by 856
Subretinal electronic chips allow blind patients to read letters and combine them to words
Zrenner, E., Bartz-Schmidt, K. U., Benav, H., Besch, D., Bruckmann, A., Gabel, V.-P., Gekeler, F., Greppmaier, U., Harscher, A., Kibbel, S., et al. (2011) · Proceedings of the Royal Society B: Biological Sciences · doi:10.1098/rspb.2010.1747 · Cited by 819
Rizzo, J. F., Wyatt, J., Loewenstein, J., Kelly, S., & Shire, D. (2003) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.02-0817 · Cited by 478
Factors affecting perceptual thresholds in epiretinal prostheses
de Balthasar, C., Patel, S., Roy, A., Freda, R., Greenwald, S., Horsager, A., Mahadevappa, M., Yanai, D., McMahon, M. J., Humayun, M. S., et al. (2008) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.07-0696 · Cited by 204
Nanduri, D., Fine, I., Horsager, A., Boynton, G. M., Humayun, M. S., Greenberg, R. J., & Weiland, J. D. (2012) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.11-8401 · Cited by 163
Wilke, R., Gabel, V.-P., Sachs, H., Bartz Schmidt, K.-U., Gekeler, F., Besch, D., Szurman, P., Stett, A., Wilhelm, B., Peters, T., et al. (2011) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.10-6946 · Cited by 155
Electric crosstalk impairs spatial resolution of multi-electrode arrays in retinal implants
Wilke, R. G. H., Moghadam, G. K., Lovell, N. H., Suaning, G. J., & Dokos, S. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/4/046016 · Cited by 110
Focal activation of the feline retina via a suprachoroidal electrode array
Wong, Y. T., Chen, S. C., Seo, J. M., Morley, J. W., Lovell, N. H., & Suaning, G. J. (2009) · Vision Research · doi:10.1016/j.visres.2009.02.018 · Cited by 109
Cited by
First-in-human trial of a novel suprachoroidal retinal prosthesis
Ayton, L. N., Blamey, P. J., Guymer, R. H., Luu, C. D., Nayagam, D. A. X., Sinclair, N. C., Shivdasani, M. N., Yeoh, J., McCombe, M. F., Briggs, R. J., et al. (2014) · PLoS ONE · doi:10.1371/journal.pone.0115239 · Cited by 333
“However, our group has shown in a preclinical feline model that not only is the suprachoroidal surgical approach feasible, reproducible and safe [23], the prosthesis is biocompatible, mechanically stable [24] and the electrode array is efficacious, with the ability to produce cortical responses within acceptable stimu…”
BackgroundSelf-citationVisual prostheses for the blind
Shepherd, R. K., Shivdasani, M. N., Nayagam, D. A. X., Williams, C. E., & Blamey, P. J. (2013) · Trends in Biotechnology · doi:10.1016/j.tibtech.2013.07.001 · Cited by 178
Self-citationCurrent steering in retinal stimulation via a quasimonopolar stimulation paradigm
Matteucci, P. B., Chen, S. C., Tsai, D., Dodds, C. W. D., Dokos, S., Morley, J. W., Lovell, N. H., & Suaning, G. J. (2013) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.13-11653 · Cited by 79
“The sigmoid was used to interpolate a current value at which the spike rate reaches that of half of maximum (P50), and this was used as an indication of variation in perceptual threshold.(36) Threshold values of P50 were calculated for hexapolar, monopolar, and quasimonopolar, and the results compared to determine the…”
BackgroundMethodInfluentialFactors Affecting Perceptual Thresholds in a Suprachoroidal Retinal Prosthesis
Shivdasani, M. N., Sinclair, N. C., Dimitrov, P. N., Varsamidis, M., Ayton, L. N., Luu, C. D., Perera, T., McDermott, H. J., & Blamey, P. J. (2014) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.14-14396 · Cited by 78
Self-citationStimulation strategies for improving the resolution of retinal prostheses
Tong, W., Meffin, H., Garrett, D. J., & Ibbotson, M. R. (2020) · Frontiers in Neuroscience · doi:10.3389/fnins.2020.00262 · Cited by 66
Virtual electrodes by current steering in retinal prostheses
Dumm, G., Fallon, J. B., Williams, C. E., & Shivdasani, M. N. (2014) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.14-15391 · Cited by 63
Self-citationVillalobos, J., Nayagam, D. A. X., Allen, P. J., McKelvie, P., Luu, C. D., Ayton, L. N., Freemantle, A. L., McPhedran, M., Basa, M., McGowan, C. C., et al. (2013) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.12-10843 · Cited by 63
Self-citationThe appearance of phosphenes elicited using a suprachoroidal retinal prosthesis
Sinclair, N. C., Shivdasani, M. N., Perera, T., Gillespie, L. N., McDermott, H. J., Ayton, L. N., Blamey, P. J., & for the Bionic Vision Australia Consortium (2016) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.15-18991 · Cited by 60
“, common ground, hexagonal, pseudo-hexagonal) were able to limit the spread of retinal and cortical activation when compared to monopolar stimulation.(36,51) A caveat to be noted is that in this study and all reported preclinical studies, only single-electrode stimulation was used.”
ResultSelf-citationOptical stimulation of neural tissue
Richardson, R. T., Ibbotson, M. R., Thompson, A. C., Wise, A. K., & Fallon, J. B. (2020) · Healthcare Technology Letters · doi:10.1049/htl.2019.0114 · Cited by 40
Self-citationComputational challenges and opportunities for a bi-directional artificial retina
Shah, N. P., & Chichilnisky, E. J. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/aba8b1 · Cited by 39
Shivdasani, M. N., Sinclair, N. C., Gillespie, L. N., Petoe, M. A., Titchener, S. A., Fallon, J. B., Perera, T., Pardinas-Diaz, D., Barnes, N. M., Blamey, P. J., et al. (2017) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.16-21311 · Cited by 38
Self-citationSpencer, T. C., Fallon, J. B., Thien, P. C., & Shivdasani, M. N. (2016) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.16-19325 · Cited by 31
Self-citationYan, Y., Lu, Y., Li, M., Ma, Z., Cao, P., Chen, Y., Sun, X., Chai, X., Ren, Q., & Li, L. (2016) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.15-17543 · Cited by 20
Retinal prostheses: where to from here?
Allen, P. J. (2021) · Clinical & Experimental Ophthalmology · doi:10.1111/ceo.13950 · Cited by 20
Self-citationCicione, R., Fallon, J. B., Rathbone, G. D., Williams, C. E., & Shivdasani, M. N. (2014) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.14-14754 · Cited by 17
Self-citationBorda, E., Gaillet, V., Airaghi Leccardi, M. J. I., Zollinger, E. G., Moreira, R. C., & Ghezzi, D. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac6d7e · Cited by 11
“Other stimulation configurations using adjacent electrodes as the return were widely investigated in cochlear implants and visual prostheses, including bipolar, tripolar and hexapolar [14, 15].”
MethodNeural Activity Shaping in Visual Prostheses with Deep Learning
Castro, D., Grayden, D. B., Meffin, H., & Spencer, M. (2023) · doi:10.1101/2023.12.20.572123 · Cited by 4
Metadata
- Authors
- Cicione, R., Shivdasani, M. N., Fallon, J. B., Luu, C. D., Allen, P. J., Rathbone, G. D., Shepherd, R. K., & Williams, C. E.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2012-05-18
- Volume
- 9
- Issue
- 3
- Pages
- 036009
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2075123461
- Cited by
- 80
- References
- 12
- FWCI
- 4.32
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.