Left atrial linear lesions are required for successful treatment of persistent atrial fibrillation
The DOI matches its Crossref record; 48 of the 48 references it cites were found in a registry or an index.
Abstract
AIMS: This study evaluates the clinical outcome and incidence of left atrial (LA) macro re-entrant atrial tachycardia (AT) in patients in whom persistent atrial fibrillation (AF) terminated during catheter ablation without the need of roof and mitral lines. METHODS AND RESULTS: Persistent AF was terminated by ablation in 154 of 180 consecutive patients. AF history was 60 months including 11 months of continuous AF. Patients were divided into two groups: those who had not required both LA linear lesions to terminate AF (group A, 85 patients), and those who had (group B, 69 patients). There was no difference in clinical and echocardiographic characteristics between both groups except for a shorter duration of continuous AF in group A (9 vs.12 months, respectively) (P = 0.03). After 28 months of follow-up, the incidence of LA macro re-entrant AT necessitating linear ablation was higher in group A (76%) compared with group B (33%) (P = 0.002). When complete linear block could not be achieved during the index procedure, the incidence of subsequent roof (P = 0.008) or mitral isthmus (P = 0.010) dependent macro re-entrant AT was higher. CONCLUSION: Although persistent AF can be terminated by catheter ablation without linear lesions, the majority will require linear lesions for macro re-entrant AT.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fuster, V., Rydén, L. E., Cannom, D. S., Crijns, H. J., Curtis, A. B., Ellenbogen, K. A., Halperin, J. L., Le Heuzey, J.-Y., Kay, G. N., Lowe, J. E., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.177292 · Cited by 2,805
Nademanee, K., McKenzie, J., Kosar, E., Schwab, M., Sunsaneewitayakul, B., Vasavakul, T., Khunnawat, C., & Ngarmukos, T. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2003.12.054 · Cited by 2,002
Calkins, H., Brugada, J., Packer, D. L., Cappato, R., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., Haines, D. E., Haissaguerre, M., et al. (2007) · Heart Rhythm · doi:10.1016/j.hrthm.2007.04.005 · Cited by 1,701
Self-citationCalkins, H., Brugada, J., Packer, D. L., Cappato, R., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., Haines, D. E., Haissaguerre, M., et al. (2007) · Europace · doi:10.1093/europace/eum120 · Cited by 1,290
Self-citationPulmonary Vein Isolation for Paroxysmal and Persistent Atrial Fibrillation
Oral, H., Knight, B. P., Tada, H., Özaydın, M., Chugh, A., Hassan, S., Scharf, C., Lai, S. W. K., Greenstein, R., Pelosi, F., et al. (2002) · Circulation · doi:10.1161/hc0902.104712 · Cited by 1,112
Circumferential Pulmonary-Vein Ablation for Chronic Atrial Fibrillation
Oral, H., Pappone, C., Chugh, A., Good, E., Bogun, F., Pelosi, F., Bates, E. R., Lehmann, M. H., Vicedomini, G., Augello, G., et al. (2006) · New England Journal of Medicine · doi:10.1056/nejmoa050955 · Cited by 976
High-density mapping of electrically induced atrial fibrillation in humans.
Konings, K. T., Kirchhof, C. J., Smeets, J. R., Wellens, H. J., Penn, O. C., & Allessie, M. A. (1994) · Circulation · doi:10.1161/01.cir.89.4.1665 · Cited by 962
Electrophysiological Breakthroughs From the Left Atrium to the Pulmonary Veins
Haïssaguerre, M., Shah, D. C., Jaïs, P., Hocini, M., Yamane, T., Deisenhofer, I., Chauvin, M., Garrigue, S., & Clémenty, J. (2000) · Circulation · doi:10.1161/01.cir.102.20.2463 · Cited by 952
Self-citationOral, H., Scharf, C., Chugh, A., Hall, B., Cheung, P., Good, E., Veerareddy, S., Pelosi, F., & Morady, F. (2003) · Circulation · doi:10.1161/01.cir.0000095796.45180.88 · Cited by 896
Catheter Ablation for Atrial Fibrillation in Congestive Heart Failure
Hsu, L.-F., Jaïs, P., Sanders, P., Garrigue, S., Hocini, M., Sacher, F., Takahashi, Y., Rotter, M., Pasquié, J.-L., Scavée, C., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa041018 · Cited by 892
Self-citationSanders, P., Berenfeld, O., Hocini, M., Jaïs, P., Vaidyanathan, R., Hsu, L.-F., Garrigue, S., Takahashi, Y., Rotter, M., Sacher, F., et al. (2005) · Circulation · doi:10.1161/circulationaha.104.517011 · Cited by 877
Self-citationTechnique and Results of Linear Ablation at the Mitral Isthmus
Jaïs, P., Hocini, M., Hsu, L.-F., Sanders, P., Scavee, C., Weerasooriya, R., Macle, L., Raybaud, F., Garrigue, S., Shah, D. C., et al. (2004) · Circulation · doi:10.1161/01.cir.0000146917.75041.58 · Cited by 751
Self-citationAnatomy of the Left Atrium: Implications for Radiofrequency Ablation of Atrial Fibrillation
YEN HO, S., SANCHEZ‐QUINTANA, D., CABRERA, J. A., & ANDERSON, R. H. (1999) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.1999.tb00211.x · Cited by 691
HAÏSSAGUERRE, M., SANDERS, P., HOCINI, M., TAKAHASHI, Y., ROTTER, M., SACHER, F., ROSTOCK, T., HSU, L., BORDACHAR, P., REUTER, S., et al. (2005) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2005.00307.x · Cited by 675
Self-citationHigh-density mapping of electrically induced atrial fibrillation in humans
Konings, K. T. S., Kirchhof, C. J. H. J., Smeets, J. R. L. M., Wellens, H. J. J., Penn, O. C., & Allessie, M. A. (2000) · Professor Hein J.J. Wellens: 33 Years of Cardiology and Arrhythmology · doi:10.1007/978-94-011-4110-9_54 · Cited by 560
Hocini, M., Jaïs, P., Sanders, P., Takahashi, Y., Rotter, M., Rostock, T., Hsu, L.-F., Sacher, F., Reuter, S., Clémenty, J., et al. (2005) · Circulation · doi:10.1161/circulationaha.105.541052 · Cited by 494
Self-citationRadiofrequency Catheter Ablation of Chronic Atrial Fibrillation Guided by Complex Electrograms
Oral, H., Chugh, A., Good, E., Wimmer, A., Dey, S., Gadeela, N., Sankaran, S., Crawford, T., Sarrazin, J. F., Kuhne, M., et al. (2007) · Circulation · doi:10.1161/circulationaha.107.691386 · Cited by 376
Chen, S. A., Chiang, C. E., Yang, C. J., Cheng, C. C., Wu, T. J., Wang, S. P., Chiang, B. N., & Chang, M. S. (1994) · Circulation · doi:10.1161/01.cir.90.3.1262 · Cited by 371
Pappone, C., Manguso, F., Vicedomini, G., Gugliotta, F., Santinelli, O., Ferro, A., Gulletta, S., Sala, S., Sora, N., Paglino, G., et al. (2004) · Circulation · doi:10.1161/01.cir.0000147186.83715.95 · Cited by 352
Willems, S., Klemm, H., Rostock, T., Brandstrup, B., Ventura, R., Steven, D., Risius, T., Lutomsky, B., & Meinertz, T. (2006) · European Heart Journal · doi:10.1093/eurheartj/ehl093 · Cited by 332
Mechanisms of organized left atrial tachycardias occurring after pulmonary vein isolation
Gerstenfeld, E. P., Callans, D. J., Dixit, S., Russo, A. M., Nayak, H., Lin, D., Pulliam, W., Siddique, S., & Marchlinski, F. E. (2004) · Circulation · doi:10.1161/01.cir.0000141369.50476.d3 · Cited by 300
Catheter-induced linear lesions in theleft atrium in patients with atrial fibrillation
Ernst, S., Ouyang, F., Löber, F., Antz, M., & Kuck, K.-H. (2003) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(03)00940-9 · Cited by 249
FASSINI, G., RIVA, S., CHIODELLI, R., TREVISI, N., BERTI, M., CARBUCICCHIO, C., MACCABELLI, G., GIRALDI, F., & BELLA, P. D. (2005) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2005.50192.x · Cited by 244
Oral, H., Chugh, A., Lemola, K., Cheung, P., Hall, B., Good, E., Han, J., Tamirisa, K., Bogun, F., Pelosi, F., et al. (2004) · Circulation · doi:10.1161/01.cir.0000146786.87037.26 · Cited by 243
Differential pacing for distinguishing block from persistent conduction through an ablation line
Shah, D., Haïssaguerre, M., Takahashi, A., Jaïs, P., Hocini, M., & Clémenty, J. (2000) · Circulation · doi:10.1161/01.cir.102.13.1517 · Cited by 242 · cited 1×
“Differential pacing was also used to exclude slow conduction on the mitral line.(12,32) (iv) The RA and superior vena cava were targeted for ablation if implicated as a source perpetuating AF and only after all LA ablation steps.”
MethodSelf-citationTakahashi, Y., O’Neill, M. D., Hocini, M., Dubois, R., Matsuo, S., Knecht, S., Mahapatra, S., Lim, K.-T., Jaïs, P., Jonsson, A., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.10.056 · Cited by 239
Self-citationLocalized Sources Maintaining Atrial Fibrillation Organized by Prior Ablation
Haïssaguerre, M., Hocini, M., Sanders, P., Takahashi, Y., Rotter, M., Sacher, F., Rostock, T., Hsu, L.-F., Jonsson, A., O’Neill, M. D., et al. (2006) · Circulation · doi:10.1161/circulationaha.105.546648 · Cited by 231
Self-citationLeft atrial tachycardia after circumferential pulmonary vein ablation for atrial fibrillation
Mesas, C. É. E., Pappone, C., Lang, C. C. E., Gugliotta, F., Tomita, T., Vicedomini, G., Sala, S., Paglino, G., Gulletta, S., Ferro, A., et al. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.05.072 · Cited by 219
Localized Sources Maintaining Atrial Fibrillation Organized by Prior Ablation
Waldo, A. L. (2007) · Yearbook of Cardiology · doi:10.1016/s0145-4145(08)70275-2 · Cited by 193
Kottkamp, H., Tanner, H., Kobza, R., Schirdewahn, P., Dorszewski, A., Gerds-Li, J.-H., Carbucicchio, C., Piorkowski, C., & Hindricks, G. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.04.049 · Cited by 191
Left Atrial Isthmus: Anatomic Aspects Relevant for Linear Catheter Ablation Procedures in Humans
BECKER, A. E. (2004) · Journal of Cardiovascular Electrophysiology · doi:10.1046/j.1540-8167.2004.03651.x · Cited by 180
KANAGARATNAM, L., TOMASSONI, G., SCHWEIKERT, R., PAVIA, S., BASH, D., BEHEIRY, S., LESH, M., NIEBAUER, M., SALIBA, W., CHUNG, M., et al. (2001) · Pacing and Clinical Electrophysiology · doi:10.1046/j.1460-9592.2001.01774.x · Cited by 176
Efficacy and safety of septal and left-atrial linear ablation for atrial fibrillation
Jaı̈s, P., Shah, D. C., Haı̈ssaguerre, M., Takahashi, A., Lavergne, T., Hocini, M., Garrigue, S., Barold, S. S., Le Métayer, P., & Clémenty, J. (1999) · The American Journal of Cardiology · doi:10.1016/s0002-9149(99)00714-6 · Cited by 173
Self-citationGaita, F., Riccardi, R., Caponi, D., Shah, D., Garberoglio, L., Vivalda, L., Dulio, A., Chiecchio, A., Manasse, E., & Gallotti, R. (2005) · Circulation · doi:10.1161/01.cir.0000151310.00337.fa · Cited by 172
Acute Occlusion of the Left Circumflex Coronary Artery During Mitral Isthmus Linear Ablation
TAKAHASHI, Y., JAÏS, P., HOCINI, M., SANDERS, P., ROTTER, M., ROSTOCK, T., SACHER, F., JAÏS, C., CLÉMENTY, J., & HAÏSSAGUERRE, M. (2005) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2005.50124.x · Cited by 150
Self-citationDual-Loop Intra-Atrial Reentry in Humans
Shah, D., Jaïs, P., Takahashi, A., Hocini, M., Peng, J. T., Clementy, J., & Haïssaguerre, M. (2000) · Circulation · doi:10.1161/01.cir.101.6.631 · Cited by 146
Self-citationTakahashi, Y., O'Neill, M. D., Hocini, M., Réant, P., Jonsson, A., Jaı̈s, P., Sanders, P., Rostock, T., Rotter, M., Sacher, F., et al. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.11.033 · Cited by 135
Self-citationSanders, P., Jaïs, P., Hocini, M., Hsu, L., Scavée, C., Sacher, F., Rotter, M., Takahashi, Y., Pasquié, J., Shah, D. C., et al. (2004) · Heart Rhythm · doi:10.1016/j.hrthm.2004.03.072 · Cited by 132
Self-citationCharacterization of Focal Atrial Tachycardia Using High-Density Mapping
Sanders, P., Hocini, M., Jaïs, P., Hsu, L., Takahashi, Y., Rotter, M., Scavée, C., Pasquié, J., Sacher, F., Rostock, T., et al. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.08.044 · Cited by 127
Self-citationSanders, P., Hocini, M., Jaïs, P., Sacher, F., Hsu, L., Takahashi, Y., Rotter, M., Rostock, T., Nalliah, C. J., Clémenty, J., et al. (2007) · European Heart Journal · doi:10.1093/eurheartj/ehl548 · Cited by 120
Self-citationROSTOCK, T., O'NEILL, M. D., SANDERS, P., ROTTER, M., JAÏS, P., HOCINI, M., TAKAHASHI, Y., SACHER, F., JÖNSSON, A., HSU, L., et al. (2006) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2006.00585.x · Cited by 109
Self-citationAtrial fibrillatory cycle length: computer simulation and potential clinical importance
Haissaguerre, M., Lim, K.-T., Jacquemet, V., Rotter, M., Dang, L., Hocini, M., Matsuo, S., Knecht, S., Jais, P., & Virag, N. (2007) · Europace · doi:10.1093/europace/eum208 · Cited by 93
Self-citationEvaluation of a radiation protection cabin for invasive electrophysiological procedures
Dragusin, O., Weerasooriya, R., Jais, P., Hocini, M., Ector, J., Takahashi, Y., Haissaguerre, M., Bosmans, H., & Heidbuchel, H. (2006) · European Heart Journal · doi:10.1093/eurheartj/ehl420 · Cited by 90
Self-citationPopping Phenomena in Temperature‐Controlled Radiofrequency Ablation: When and Why Do They Occur?
EICK, O. J., Gerritse, B., & Schumacher, B. M. (2000) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2000.tb00807.x · Cited by 83
Wu, J., Estner, H., Luik, A., Üçer, E., Reents, T., Pflaumer, A., Zrenner, B., Hessling, G., & Deisenhofer, I. (2008) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2008.01145.x · Cited by 77
CUMMINGS, J. E., SCHWEIKERT, R., SALIBA, W., HAO, S., MARTIN, D. O., MARROUCHE, N. F., BURKHARDT, J. D., KILICASLAN, F., VERMA, A., BEHEIRY, S., et al. (2005) · Journal of Cardiovascular Electrophysiology · doi:10.1046/j.1540-8167.2005.40585.x · Cited by 73
Left Atrial Flutter After Radiofrequency Catheter Ablation of Focal Atrial Fibrillation
VILLACASTÍN, J., PÉREZ‐CASTELLANO, N., MORENO, J., & GONZÁLEZ, R. (2003) · Journal of Cardiovascular Electrophysiology · doi:10.1046/j.1540-8167.2003.02418.x · Cited by 70
MARTINEK, M., AICHINGER, J., NESSER, H., ZIEGLER, P. D., & PURERFELLNER, H. (2007) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2007.00883.x · Cited by 69
Cited by
Approaches to catheter ablation for persistent atrial fibrillation
Verma, A., Jiang, C.-Y., Betts, T. R., Chen, J., Deisenhofer, I., Mantovan, R., Macle, L., Morillo, C. A., Haverkamp, W., Weerasooriya, R., et al. (2015) · New England Journal of Medicine · doi:10.1056/nejmoa1408288 · Cited by 2,339
Jones, D. G., Haldar, S. K., Hussain, W., Sharma, R., Francis, D. P., Rahman-Haley, S. L., McDonagh, T. A., Underwood, S. R., Markides, V., & Wong, T. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2013.01.069 · Cited by 481
O'Neill, M. D., Wright, M., Knecht, S., Jais, P., Hocini, M., Takahashi, Y., Jonsson, A., Sacher, F., Matsuo, S., Lim, K. T., et al. (2009) · European Heart Journal · doi:10.1093/eurheartj/ehp063 · Cited by 333
Self-citationScherr, D., Khairy, P., Miyazaki, S., Aurillac-Lavignolle, V., Pascale, P., Wilton, S. B., Ramoul, K., Komatsu, Y., Roten, L., Jadidi, A., et al. (2015) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.114.001943 · Cited by 303
“Electrophysiological Study and Ablation Procedure Details of the peri-procedural management and the ablation technique at our institution have been described previously.(1-8) As it is standard clinical practice at our institution, all AADs were discontinued at least five half-lives prior to ablation except for amiodar…”
BackgroundMethodInfluentialSelf-citationLee, J. M., Shim, J., Park, J., Yu, H. T., Kim, T.-H., Park, J.-K., Uhm, J.-S., Kim, J.-B., Joung, B., Lee, M.-H., et al. (2019) · JACC: Clinical Electrophysiology · doi:10.1016/j.jacep.2019.08.021 · Cited by 206
Metadata
- Authors
- Knecht, S., Hocini, M., Wright, M., Lellouche, N., O'Neill, M. D., Matsuo, S., Nault, I., Chauhan, V. S., Makati, K. J., Bevilacqua, M., Lim, K.-T., Sacher, F., Deplagne, A., Derval, N., Bordachar, P., Jais, P., Clementy, J., & Haissaguerre, M.
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2008-07-08
- Volume
- 29
- Issue
- 19
- Pages
- 2359-2366
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W2033972079
- Cited by
- 259
- References
- 48
- FWCI
- 14.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.