Reliability of point-of-care testing for glucose measurement in critically ill adults*
The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Glycemic control is increasingly being recognized as a priority in the treatment of critically ill patients. Titration and monitoring of insulin infusions involve frequent blood glucose measurement to achieve target glucose ranges and prevent adverse events related to hypoglycemia. Therefore, it is imperative that bedside glucose testing methods be safe and accurate. OBJECTIVE: To determine the accuracy and clinical impact of three common methods of bedside point-of-care testing for glucose measurements in critically ill patients receiving insulin infusions. DESIGN: Prospective observational study. SETTING: A 21-bed mixed medical/surgical intensive care unit of a tertiary care teaching hospital. PATIENTS: Thirty consecutive critically ill patients who were vasopressor-dependent (n = 10), had significant peripheral edema (n = 10), or were admitted following major surgery (n = 10). MEASUREMENTS: Findings from three different methods of glucose measurement were compared with central laboratory measurements: (1) glucose meter analysis of capillary blood (fingerstick); (2) glucose meter analysis of arterial blood; and (3) blood gas/chemistry analysis of arterial blood. Patients were enrolled for a maximum of 3 days and had a maximum of nine sets of measurements determined during this time. RESULTS: Clinical agreement with the central laboratory was significantly better with arterial blood analysis (69.9% and 76.5% for glucose meter and blood gas/chemistry analysis, respectively) than with capillary blood analysis (56.8%; p = .039 and .001, respectively). During hypoglycemia, clinical agreement was only 26.3% with capillary blood analysis and 55.6% and 64.9% for glucose meter and blood gas/chemistry analysis of arterial blood (p = .010 and <.001, respectively). Glucose meter analysis of both arterial and capillary blood tended to provide higher glucose values, whereas blood gas/chemistry analysis of arterial blood tended to yield lower glucose values. CONCLUSIONS: The magnitude of the differences in the glucose values offered by the four different methods of glucose measurement led to frequent clinical disagreements regarding insulin dose titration in the context of an insulin infusion protocol for aggressive glucose control.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
(1965) · The Lancet · doi:10.1016/s0140-6736(65)91037-8 · Cited by 16,856
Intensive insulin therapy in critically ill patients.
Van den Berghe, G., Wouters, P., Weekers, F., Verwaest, C., Bruyninckx, F., Schetz, M., Vlasselaers, D., Ferdinande, P., Lauwers, P., & Bouillon, R. (2001) · New England Journal of Medicine · doi:10.1056/nejmoa011300 · Cited by 9,977
Tang, Z., Lee, J. H., Louie, R. F., & Kost, G. J. (2000) · Archives of Pathology & Laboratory Medicine · doi:10.5858/2000-124-1135-eodhlo · Cited by 293
Kanji, S., Singh, A., Tierney, M., Meggison, H., McIntyre, L., & Hebert, P. C. (2004) · Intensive Care Medicine · doi:10.1007/s00134-004-2252-2 · Cited by 208
Self-citationFingerstick Glucose Determination in Shock
Atkin, S. H., Dasmahapatra, A., Jaker, M. A., Chorost, M. I., & Reddy, S. (1991) · Annals of Internal Medicine · doi:10.7326/0003-4819-114-12-1020 · Cited by 189
Tang, Z., Louie, R. F., Lee, J. H., Lee, D. M., Miller, E. E., & Kost, G. J. (2001) · Critical Care Medicine · doi:10.1097/00003246-200105000-00038 · Cited by 188
Louie, R. F., Tang, Z., Sutton, D. V., Lee, J. H., & Kost, G. J. (2000) · Archives of Pathology & Laboratory Medicine · doi:10.5858/2000-124-0257-pocgt · Cited by 180
Tang, Z., Du, X., Louie, R. F., & Kost, G. J. (2000) · Archives of Pathology & Laboratory Medicine · doi:10.5858/2000-124-0577-eopogm · Cited by 92
Accuracy of fingerstick glucose values in shock patients
Sylvain, H., Pokorny, M., English, S., Benson, N., Whitley, T., Ferenczy, C., & Harrison, J. (1995) · American Journal of Critical Care · doi:10.4037/ajcc1995.4.1.44 · Cited by 89
Cited by
Surviving Sepsis Campaign: International Guidelines for Management of Severe Sepsis and Septic Shock
Dellinger, R. P., Levy, M. M., Rhodes, A., Annane, D., Gerlach, H., Opal, S. M., Sevransky, J. E., Sprung, C. L., Douglas, I. S., Jaeschke, R., et al. (2013) · Critical Care Medicine · doi:10.1097/ccm.0b013e31827e83af · Cited by 9,694
The Surviving Sepsis Campaign Guidelines Committee including The Pediatric Subgroup*, Dellinger, R. P., Levy, M. M., Rhodes, A., Annane, D., Gerlach, H., Opal, S. M., Sevransky, J. E., Sprung, C. L., Douglas, I. S., et al. (2013) · Intensive Care Medicine · doi:10.1007/s00134-012-2769-8 · Cited by 7,290
Dellinger, R. P., Levy, M. M., Carlet, J. M., Bion, J., Parker, M. M., Jaeschke, R., Reinhart, K., Angus, D. C., Brun-Buisson, C., Beale, R., et al. (2008) · Intensive Care Medicine · doi:10.1007/s00134-007-0934-2 · Cited by 6,772
Surviving Sepsis Campaign: International guidelines for management of sepsis and septic shock: 2016.
Rhodes, A., Evans, L. E., Alhazzani, W., Levy, M. M., Antonelli, M., Ferrer, R., Kumar, A., Sevransky, J. E., Sprung, C. L., Nunnally, M. E., et al. (2017) · Intensive Care Medicine · doi:10.1007/s00134-017-4683-6 · Cited by 6,621
Self-citationSevere Sepsis and Septic Shock
Angus, D. C., & van der Poll, T. (2013) · New England Journal of Medicine · doi:10.1056/nejmra1208623 · Cited by 3,961
Surviving Sepsis Campaign: International guidelines for management of sepsis and septic shock: 2016.
Rhodes, A., Evans, L. E., Alhazzani, W., Levy, M. M., Antonelli, M., Ferrer, R., Kumar, A., Sevransky, J. E., Sprung, C. L., Nunnally, M. E., et al. (2017) · Critical Care Medicine · doi:10.1097/ccm.0000000000002255 · Cited by 3,652
Self-citationSacks, D. B., Arnold, M., Bakris, G. L., Bruns, D. E., Horvath, A. R., Kirkman, M. S., Lernmark, A., Metzger, B. E., & Nathan, D. M. (2011) · Clinical Chemistry · doi:10.1373/clinchem.2010.161596 · Cited by 1,360
“Similarly, a 2005 study of arterial, venous, and capillary samples from amixedmedical/surgical ICU of a tertiary care hospital in Canada found that meters did not meet proposed CLSI goals but that a blood gas analyzer did (143).”
Preiser, J.-C., Devos, P., Ruiz-Santana, S., Mélot, C., Annane, D., Groeneveld, J., Iapichino, G., Leverve, X., Nitenberg, G., Singer, P., et al. (2009) · Intensive Care Medicine · doi:10.1007/s00134-009-1585-2 · Cited by 911
“To avoid excessive heterogeneity and inaccuracy in the measurement of glucose concentration, only a validated model of glucose analyser was allowed [37].”
MethodGlycemic variability: A strong independent predictor of mortality in critically ill patients.
Krinsley, J. S. (2008) · Critical Care Medicine · doi:10.1097/ccm.0b013e31818b38d2 · Cited by 729
“These include, in part: strict adherence to the treatment protocol in place in the ICU; appropriate data outcome tools to ensure rapid and continuous feedback to the clinical staff about their efforts; and the use of glucose monitoring devices that remain accurate within the extremes of blood pressure, body temperatur…”
BackgroundSacks, D. B., Arnold, M., Bakris, G. L., Bruns, D. E., Horvath, A. R., Kirkman, M. S., Lernmark, A., Metzger, B. E., & Nathan, D. M. (2011) · Diabetes Care · doi:10.2337/dc11-9998 · Cited by 718
“Similarly, a 2005 study of arterial, venous, and capillary samples from amixedmedical/surgical ICU of a tertiary care hospital in Canada found that meters did not meet proposed CLSI goals but that a blood gas analyzer did (143).”
Severe hypoglycemia in critically ill patients: risk factors and outcomes
Krinsley, J. S., & Grover, A. (2007) · Critical Care Medicine · doi:10.1097/01.ccm.0000282073.98414.4b · Cited by 671
“Therefore, SH was not defined in exactly the same way, because arterial blood glucose levels tend to be somewhat higher than those found in contemporaneously measured plasma glucose (25).”
BackgroundHyperglycemia-related mortality in critically ill patients varies with admission diagnosis
Falciglia, M., Freyberg, R. W., Almenoff, P. L., D’Alessio, D. A., & Render, M. L. (2009) · Critical Care Medicine · doi:10.1097/ccm.0b013e3181b083f7 · Cited by 576
Jacobi, J., Bircher, N., Krinsley, J., Agus, M., Braithwaite, S. S., Deutschman, C., Freire, A. X., Geehan, D., Kohl, B., Nasraway, S. A., et al. (2012) · Critical Care Medicine · doi:10.1097/ccm.0b013e3182653269 · Cited by 571
Krinsley, J. S., Egi, M., Kiss, A., Devendra, A. N., Schuetz, P., Maurer, P. M., Schultz, M. J., van Hooijdonk, R. T., Kiyoshi, M., Mackenzie, I. M., et al. (2013) · Critical Care · doi:10.1186/cc12547 · Cited by 369
Toward Understanding Tight Glycemic Control in the ICU
Marik, P. E., & Preiser, J.-C. (2010) · Chest · doi:10.1378/chest.09-1737 · Cited by 365
Simple, distance-based measurement for paper analytical devices
Cate, D. M., Dungchai, W., Cunningham, J. C., Volckens, J., & Henry, C. S. (2013) · Lab on a Chip · doi:10.1039/c3lc50072a · Cited by 348
Joshi, G. P., Chung, F., Vann, M. A., Ahmad, S., Gan, T. J., Goulson, D. T., Merrill, D. G., & Twersky, R. (2010) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e3181f9c288 · Cited by 298
Glucose Measurement: Confounding Issues in Setting Targets for Inpatient Management
Dungan, K., Chapman, J., Braithwaite, S. S., & Buse, J. (2007) · Diabetes Care · doi:10.2337/dc06-1679 · Cited by 292
Perioperative Glycemic Control: An Evidence-based Review
Lipshutz, A. K. M., Gropper, M. A., Warner, D. S., & Warner, M. A. (2009) · Anesthesiology · doi:10.1097/aln.0b013e3181948a80 · Cited by 259
Intensive Insulin Therapy in Hospitalized Patients: A Systematic Review
Kansagara, D., Fu, R., Freeman, M., Wolf, F., & Helfand, M. (2011) · Annals of Internal Medicine · doi:10.7326/0003-4819-154-4-201102150-00008 · Cited by 255
Clinical experience with tight glucose control by intensive insulin therapy
Preiser, J.-C., & Devos, P. (2007) · Critical Care Medicine · doi:10.1097/01.ccm.0000278046.24345.c7 · Cited by 253
Egi, M., Ogura, H., Yatabe, T., Atagi, K., Inoue, S., Iba, T., Kakihana, Y., Kawasaki, T., Kushimoto, S., Kuroda, Y., et al. (2021) · Journal of Intensive Care · doi:10.1186/s40560-021-00555-7 · Cited by 224
Continuous glucose monitoring: an Endocrine Society Clinical Practice Guideline
Klonoff, D. C., Buckingham, B., Christiansen, J. S., Montori, V. M., Tamborlane, W. V., Vigersky, R. A., & Wolpert, H. (2011) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2010-2756 · Cited by 211
Fokkert, M. J., van Dijk, P. R., Edens, M. A., Abbes, S., de Jong, D., Slingerland, R. J., & Bilo, H. J. G. (2017) · BMJ Open Diabetes Research & Care · doi:10.1136/bmjdrc-2016-000320 · Cited by 209
Finfer, S., Wernerman, J., Preiser, J.-C., Cass, T., Desaive, T., Hovorka, R., Joseph, J. I., Kosiborod, M., Krinsley, J., Mackenzie, I., et al. (2013) · Critical Care · doi:10.1186/cc12537 · Cited by 208
“Th e accuracy of glucose meters has been the subject of a number of studies, with the near-universal conclusion that they are not suffi ciently accurate for use in the ICU [2,4,5,16].”
InfluentialKrinsley, J. S., & Preiser, J.-C. (2015) · Critical Care · doi:10.1186/s13054-015-0908-7 · Cited by 174
“Although this method of analysis has been associated with analytic inaccuracies [31-33], it remains the standard of care in many ICUs, especially in the United States.”
MethodAccuracy of bedside glucose measurement from three glucometers in critically ill patients*
Hoedemaekers, C. W. E., Klein Gunnewiek, J. M. T., Prinsen, M. A., Willems, J. L., & Van der Hoeven, J. G. (2008) · Critical Care Medicine · doi:10.1097/ccm.0b013e318186ffe6 · Cited by 165
A.S.P.E.N. Clinical Guidelines: Nutrition Support of Adult Patients With Hyperglycemia
McMahon, M. M., Nystrom, E., Braunschweig, C., Miles, J., Compher, C., & the American Society for Parenteral and Enteral Nutrition (A.S.P.E.N.) Board of Directors (2013) · Journal of Parenteral and Enteral Nutrition · doi:10.1177/0148607112452001 · Cited by 164
“The accuracy and precision of blood glucose monitoring devices is relatively poor, especially at low glucose concentrations.(14,58) Using a blood glucose threshold of 70 mg/dL (3.”
BackgroundThe Accuracy of Point-of-Care Glucose Measurements
Rebel, A., Rice, M. A., & Fahy, B. G. (2012) · Journal of Diabetes Science and Technology · doi:10.1177/193229681200600228 · Cited by 144
International recommendations for glucose control in adult non diabetic critically ill patients
Ichai, C., Preiser, J.-C., (SFAR), F. T. S. F. D.-R., & Société de Réanimation de langue Française (SRLF) and the Experts group (2010) · Critical Care · doi:10.1186/cc9258 · Cited by 127
“The main sources of discrepancies are vasoconstriction, low blood flow rate, a state of shock, ischemia, or edema [54,78,79].”
BackgroundResultInfluentialGlucose meter performance criteria for tight glycemic control estimated by simulation modeling
Karon, B. S., Boyd, J. C., & Klee, G. G. (2010) · Clinical Chemistry · doi:10.1373/clinchem.2010.145367 · Cited by 94
Tight glycaemic control by an automated algorithm with time-variant sampling in medical icu patients
Pachler, C., Plank, J., Weinhandl, H., Chassin, L. J., Wilinska, M. E., Kulnik, R., Kaufmann, P., Smolle, K.-H., Pilger, E., Pieber, T. R., et al. (2008) · Intensive Care Medicine · doi:10.1007/s00134-008-1033-8 · Cited by 82
Allardet-Servent, J., Lebsir, M., Dubroca, C., Fabrigoule, M., Jordana, S., Signouret, T., Castanier, M., Thomas, G., Soundaravelou, R., Lepidi, A., et al. (2017) · PLOS ONE · doi:10.1371/journal.pone.0169593 · Cited by 64
DuBois, J. A., Slingerland, R. J., Fokkert, M., Roman, A., Tran, N. K., Clarke, W., Sartori, D. A., Palmieri, T. L., Malic, A., Lyon, M. E., et al. (2017) · Critical Care Medicine · doi:10.1097/ccm.0000000000002252 · Cited by 59
Assessing the quality of glucose monitor studies: a critical evaluation of published reports
Mahoney, J., & Ellison, J. (2007) · Clinical Chemistry · doi:10.1373/clinchem.2006.083493 · Cited by 48
“Our PubMed search terms and details were as follows: (“blood glucose”[MeSH Terms] OR blood glucose[Text Word]) AND (performance[Text Word] OR evaluation[Text Word] OR accurate[Text Word] OR accuracy[Text Word] OR point-of-care[Text Word] OR meter[Text Word] OR meters[Text Word] OR glucometer[Text…”
MethodSaur, N. M., Kongable, G. L., Holewinski, S., O’Brien, K., & Nasraway, S. A. (2013) · Mayo Clinic Proceedings · doi:10.1016/j.mayocp.2013.07.003 · Cited by 37
Management of type 1 diabetes in the hospital setting
Mendez, C. E., & Umpierrez, G. E. (2017) · Current Diabetes Reports · doi:10.1007/s11892-017-0919-7 · Cited by 34
A patient-level meta-analysis of intensive glucose control in critically ill adults
Adigbli, D., Li, Y., Hammond, N., Chatoor, R., Devaux, A. G., Li, Q., Billot, L., Annane, D., Arabi, Y., Bilotta, F., et al. (2024) · NEJM Evidence · doi:10.1056/evidoa2400082 · Cited by 25
Karon, B. S., Meeusen, J. W., & Bryant, S. C. (2016) · Journal of Diabetes Science and Technology · doi:10.1177/1932296815602099 · Cited by 16
“is observed at glucose concentrations > 150 mg/dL.(6,26) Because simulation models are limited in the ability to model the effects of changing bias or precision,(16) the inability to adequately model the effects of proportional positive bias observed with GM1 may have caused previous investigators to significantly und…”
BackgroundDellinger, R. P., Levy, M. M., Carlet, J. M., Bion, J., Parker, M. M., Jaeschke, R., Reinhart, K., Angus, D. C., Brun-Buisson, C., Beale, R., et al. (2008) · Critical Care Medicine · doi:10.1097/01.ccm.0000298158.12101.41 · Cited by 9
Barassi, A., Umbrello, M., Ghilardi, F., Damele, C. A. L., Massaccesi, L., Iapichino, G., & Melzi d’Eril, G. V. (2015) · Clinica Chimica Acta · doi:10.1016/j.cca.2014.09.008 · Cited by 8
Metadata
- Authors
- Kanji, S., Buffie, J., Hutton, B., Bunting, P. S., Singh, A., McDonald, K., Fergusson, D., McIntyre, L. A., & Hebert, P. C.
- Venue
- Critical Care Medicine
- Published
- 2005-12
- Volume
- 33
- Issue
- 12
- Pages
- 2778-2785
- ISSN
- 0090-3493 (ISSN-L)
- OpenAlex
- W2008504588
- Cited by
- 395
- References
- 13
- FWCI
- 13.50
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.